SLAC Magnetic Measurements Date: 05-25-2004 Time: 10:53:45 Project: klystron Magnet Type: solenoid Magnet Name: PEPII-SN106 Serial Number: Run Number: 6 Measurement Device: Coil 2 Operator: sda Comment: Bt vs z, collector end, I2-11 = 36.6 A, I1 = 25.6 A, Bucking = 0.0 A. tube brackets attached Test Currents (A): 36.6 10:54:02 Btcoil, device being used, type = SR850 10:54:14 Stage Zeroed 10:54:14 MoveZ Devices: Move Device = SXDRIVE, Read Device = SXDRIVE 10:54:15 Initial Zero Current Measurement, Imag_zero = 0.0000 A 10:54:15 Magnet current ramping to 36.6000 A... 10:54:35 Move Stage, position = -0.050000 10:54:37 Stage Position Measurement, pos = -0.050000 m 10:54:38 Magnet Current, Imag = 36.5634 A Vtrans = 2.925071 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:55:01 Coil Voltage Measurement meas_freq = 13.082000 Hz, meas_v_mag = 0.000075 V, meas_v_ph = 143.502000 deg freq = 13.082000 Hz, v_amp = 0.000106 V, v_ph = 53.502000 deg 10:55:01 Transverse Field Calculation freq = 13.082000 Hz, v_amp = 0.000106 V, v_ph = 53.502000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000004 T, THsp = -53.502000 deg 10:55:16 Move Stage, position = 0.000000 10:55:18 Stage Position Measurement, pos = 0.000000 m 10:55:19 Magnet Current, Imag = 36.5581 A Vtrans = 2.924651 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:55:39 Coil Voltage Measurement meas_freq = 13.077300 Hz, meas_v_mag = 0.000315 V, meas_v_ph = -12.426000 deg freq = 13.077300 Hz, v_amp = 0.000445 V, v_ph = -102.426000 deg 10:55:39 Transverse Field Calculation freq = 13.077300 Hz, v_amp = 0.000445 V, v_ph = -102.426000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000015 T, THsp = 102.426000 deg 10:55:54 Move Stage, position = 0.050000 10:55:56 Stage Position Measurement, pos = 0.050000 m 10:55:57 Magnet Current, Imag = 36.5524 A Vtrans = 2.924192 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:56:17 Coil Voltage Measurement meas_freq = 13.074900 Hz, meas_v_mag = 0.001479 V, meas_v_ph = -21.204000 deg freq = 13.074900 Hz, v_amp = 0.002092 V, v_ph = -111.204000 deg 10:56:17 Transverse Field Calculation freq = 13.074900 Hz, v_amp = 0.002092 V, v_ph = -111.204000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000070 T, THsp = 111.204000 deg 10:56:32 Move Stage, position = 0.100000 10:56:34 Stage Position Measurement, pos = 0.100000 m 10:56:35 Magnet Current, Imag = 36.5487 A Vtrans = 2.923899 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:56:55 Coil Voltage Measurement meas_freq = 13.073900 Hz, meas_v_mag = 0.000500 V, meas_v_ph = -50.754000 deg freq = 13.073900 Hz, v_amp = 0.000707 V, v_ph = -140.754000 deg 10:56:55 Transverse Field Calculation freq = 13.073900 Hz, v_amp = 0.000707 V, v_ph = -140.754000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000024 T, THsp = 140.754000 deg 10:57:10 Move Stage, position = 0.150000 10:57:12 Stage Position Measurement, pos = 0.150000 m 10:57:13 Magnet Current, Imag = 36.5446 A Vtrans = 2.923571 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:57:33 Coil Voltage Measurement meas_freq = 13.073000 Hz, meas_v_mag = 0.000476 V, meas_v_ph = -101.196000 deg freq = 13.073000 Hz, v_amp = 0.000673 V, v_ph = 168.804000 deg 10:57:33 Transverse Field Calculation freq = 13.073000 Hz, v_amp = 0.000673 V, v_ph = 168.804000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000022 T, THsp = -168.804000 deg 10:57:48 Move Stage, position = 0.200000 10:57:50 Stage Position Measurement, pos = 0.200000 m 10:57:51 Magnet Current, Imag = 36.5402 A Vtrans = 2.923217 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:58:11 Coil Voltage Measurement meas_freq = 13.080100 Hz, meas_v_mag = 0.000630 V, meas_v_ph = -106.722000 deg freq = 13.080100 Hz, v_amp = 0.000891 V, v_ph = 163.278000 deg 10:58:11 Transverse Field Calculation freq = 13.080100 Hz, v_amp = 0.000891 V, v_ph = 163.278000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000030 T, THsp = -163.278000 deg 10:58:26 Move Stage, position = 0.250000 10:58:28 Stage Position Measurement, pos = 0.250000 m 10:58:29 Magnet Current, Imag = 36.5365 A Vtrans = 2.922920 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:58:49 Coil Voltage Measurement meas_freq = 13.078700 Hz, meas_v_mag = 0.000699 V, meas_v_ph = -110.280000 deg freq = 13.078700 Hz, v_amp = 0.000988 V, v_ph = 159.720000 deg 10:58:49 Transverse Field Calculation freq = 13.078700 Hz, v_amp = 0.000988 V, v_ph = 159.720000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000033 T, THsp = -159.720000 deg 10:59:05 Move Stage, position = 0.300000 10:59:06 Stage Position Measurement, pos = 0.300000 m 10:59:07 Magnet Current, Imag = 36.5324 A Vtrans = 2.922594 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:59:28 Coil Voltage Measurement meas_freq = 13.074900 Hz, meas_v_mag = 0.000697 V, meas_v_ph = -116.964000 deg freq = 13.074900 Hz, v_amp = 0.000985 V, v_ph = 153.036000 deg 10:59:28 Transverse Field Calculation freq = 13.074900 Hz, v_amp = 0.000985 V, v_ph = 153.036000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000033 T, THsp = -153.036000 deg 10:59:43 Move Stage, position = 0.350000 10:59:45 Stage Position Measurement, pos = 0.350000 m 10:59:46 Magnet Current, Imag = 36.5289 A Vtrans = 2.922314 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:00:06 Coil Voltage Measurement meas_freq = 13.078200 Hz, meas_v_mag = 0.000619 V, meas_v_ph = -122.982000 deg freq = 13.078200 Hz, v_amp = 0.000876 V, v_ph = 147.018000 deg 11:00:06 Transverse Field Calculation freq = 13.078200 Hz, v_amp = 0.000876 V, v_ph = 147.018000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000029 T, THsp = -147.018000 deg 11:00:21 Move Stage, position = 0.400000 11:00:23 Stage Position Measurement, pos = 0.400000 m 11:00:24 Magnet Current, Imag = 36.5258 A Vtrans = 2.922065 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:00:44 Coil Voltage Measurement meas_freq = 13.080100 Hz, meas_v_mag = 0.000414 V, meas_v_ph = -121.026000 deg freq = 13.080100 Hz, v_amp = 0.000585 V, v_ph = 148.974000 deg 11:00:44 Transverse Field Calculation freq = 13.080100 Hz, v_amp = 0.000585 V, v_ph = 148.974000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000020 T, THsp = -148.974000 deg 11:00:59 Move Stage, position = 0.450000 11:01:01 Stage Position Measurement, pos = 0.450000 m 11:01:02 Magnet Current, Imag = 36.5228 A Vtrans = 2.921826 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:01:24 Coil Voltage Measurement meas_freq = 13.075400 Hz, meas_v_mag = 0.000153 V, meas_v_ph = -110.784000 deg freq = 13.075400 Hz, v_amp = 0.000216 V, v_ph = 159.216000 deg 11:01:24 Transverse Field Calculation freq = 13.075400 Hz, v_amp = 0.000216 V, v_ph = 159.216000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000007 T, THsp = -159.216000 deg 11:01:39 Move Stage, position = 0.500000 11:01:41 Stage Position Measurement, pos = 0.500000 m 11:01:42 Magnet Current, Imag = 36.5199 A Vtrans = 2.921594 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:02:05 Coil Voltage Measurement meas_freq = 13.075800 Hz, meas_v_mag = 0.000039 V, meas_v_ph = 12.486000 deg freq = 13.075800 Hz, v_amp = 0.000055 V, v_ph = -77.514000 deg 11:02:05 Transverse Field Calculation freq = 13.075800 Hz, v_amp = 0.000055 V, v_ph = -77.514000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000002 T, THsp = 77.514000 deg 11:02:20 Move Stage, position = 0.550000 11:02:22 Stage Position Measurement, pos = 0.550000 m 11:02:23 Magnet Current, Imag = 36.5170 A Vtrans = 2.921359 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:02:44 Coil Voltage Measurement meas_freq = 13.072500 Hz, meas_v_mag = 0.000168 V, meas_v_ph = 27.372000 deg freq = 13.072500 Hz, v_amp = 0.000237 V, v_ph = -62.628000 deg 11:02:44 Transverse Field Calculation freq = 13.072500 Hz, v_amp = 0.000237 V, v_ph = -62.628000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000008 T, THsp = 62.628000 deg 11:02:59 Move Stage, position = 0.600000 11:03:01 Stage Position Measurement, pos = 0.600000 m 11:03:02 Magnet Current, Imag = 36.5140 A Vtrans = 2.921118 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:03:24 Coil Voltage Measurement meas_freq = 13.072000 Hz, meas_v_mag = 0.000137 V, meas_v_ph = 12.732000 deg freq = 13.072000 Hz, v_amp = 0.000194 V, v_ph = -77.268000 deg 11:03:24 Transverse Field Calculation freq = 13.072000 Hz, v_amp = 0.000194 V, v_ph = -77.268000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000006 T, THsp = 77.268000 deg 11:03:39 Move Stage, position = 0.650000 11:03:40 Stage Position Measurement, pos = 0.650000 m 11:03:42 Magnet Current, Imag = 36.5117 A Vtrans = 2.920935 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:04:02 Coil Voltage Measurement meas_freq = 13.069600 Hz, meas_v_mag = 0.000194 V, meas_v_ph = -42.792000 deg freq = 13.069600 Hz, v_amp = 0.000275 V, v_ph = -132.792000 deg 11:04:02 Transverse Field Calculation freq = 13.069600 Hz, v_amp = 0.000275 V, v_ph = -132.792000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000009 T, THsp = 132.792000 deg 11:04:18 Move Stage, position = 0.700000 11:04:19 Stage Position Measurement, pos = 0.700000 m 11:04:20 Magnet Current, Imag = 36.5091 A Vtrans = 2.920725 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:04:40 Coil Voltage Measurement meas_freq = 13.076300 Hz, meas_v_mag = 0.000387 V, meas_v_ph = -68.196000 deg freq = 13.076300 Hz, v_amp = 0.000547 V, v_ph = -158.196000 deg 11:04:40 Transverse Field Calculation freq = 13.076300 Hz, v_amp = 0.000547 V, v_ph = -158.196000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000018 T, THsp = 158.196000 deg 11:04:56 Move Stage, position = 0.750000 11:04:57 Stage Position Measurement, pos = 0.750000 m 11:04:58 Magnet Current, Imag = 36.5064 A Vtrans = 2.920515 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:05:19 Coil Voltage Measurement meas_freq = 13.066300 Hz, meas_v_mag = 0.000576 V, meas_v_ph = -74.202000 deg freq = 13.066300 Hz, v_amp = 0.000815 V, v_ph = -164.202000 deg 11:05:19 Transverse Field Calculation freq = 13.066300 Hz, v_amp = 0.000815 V, v_ph = -164.202000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000027 T, THsp = 164.202000 deg 11:05:34 Move Stage, position = 0.800000 11:05:36 Stage Position Measurement, pos = 0.800000 m 11:05:37 Magnet Current, Imag = 36.5047 A Vtrans = 2.920378 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:05:57 Coil Voltage Measurement meas_freq = 13.063400 Hz, meas_v_mag = 0.000695 V, meas_v_ph = -75.294000 deg freq = 13.063400 Hz, v_amp = 0.000983 V, v_ph = -165.294000 deg 11:05:57 Transverse Field Calculation freq = 13.063400 Hz, v_amp = 0.000983 V, v_ph = -165.294000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000033 T, THsp = 165.294000 deg 11:06:12 Move Stage, position = 0.850000 11:06:14 Stage Position Measurement, pos = 0.850000 m 11:06:15 Magnet Current, Imag = 36.5021 A Vtrans = 2.920169 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:06:35 Coil Voltage Measurement meas_freq = 13.063400 Hz, meas_v_mag = 0.000742 V, meas_v_ph = -75.504000 deg freq = 13.063400 Hz, v_amp = 0.001050 V, v_ph = -165.504000 deg 11:06:35 Transverse Field Calculation freq = 13.063400 Hz, v_amp = 0.001050 V, v_ph = -165.504000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000035 T, THsp = 165.504000 deg 11:06:51 Move Stage, position = 0.900000 11:06:52 Stage Position Measurement, pos = 0.900000 m 11:06:53 Magnet Current, Imag = 36.5002 A Vtrans = 2.920019 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:07:14 Coil Voltage Measurement meas_freq = 13.065800 Hz, meas_v_mag = 0.000730 V, meas_v_ph = -76.134000 deg freq = 13.065800 Hz, v_amp = 0.001032 V, v_ph = -166.134000 deg 11:07:14 Transverse Field Calculation freq = 13.065800 Hz, v_amp = 0.001032 V, v_ph = -166.134000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000034 T, THsp = 166.134000 deg 11:07:29 Move Stage, position = 0.950000 11:07:31 Stage Position Measurement, pos = 0.950000 m 11:07:32 Magnet Current, Imag = 36.4987 A Vtrans = 2.919893 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:07:52 Coil Voltage Measurement meas_freq = 13.061500 Hz, meas_v_mag = 0.000662 V, meas_v_ph = -71.400000 deg freq = 13.061500 Hz, v_amp = 0.000936 V, v_ph = -161.400000 deg 11:07:52 Transverse Field Calculation freq = 13.061500 Hz, v_amp = 0.000936 V, v_ph = -161.400000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000031 T, THsp = 161.400000 deg 11:08:07 Move Stage, position = 1.000000 11:08:09 Stage Position Measurement, pos = 1.000000 m 11:08:10 Magnet Current, Imag = 36.4968 A Vtrans = 2.919747 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:08:31 Coil Voltage Measurement meas_freq = 13.063000 Hz, meas_v_mag = 0.000556 V, meas_v_ph = -73.836000 deg freq = 13.063000 Hz, v_amp = 0.000787 V, v_ph = -163.836000 deg 11:08:31 Transverse Field Calculation freq = 13.063000 Hz, v_amp = 0.000787 V, v_ph = -163.836000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000026 T, THsp = 163.836000 deg 11:08:46 Move Stage, position = 1.050000 11:08:47 Stage Position Measurement, pos = 1.050000 m 11:08:49 Magnet Current, Imag = 36.4949 A Vtrans = 2.919596 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:09:09 Coil Voltage Measurement meas_freq = 13.066300 Hz, meas_v_mag = 0.000461 V, meas_v_ph = -75.708000 deg freq = 13.066300 Hz, v_amp = 0.000652 V, v_ph = -165.708000 deg 11:09:09 Transverse Field Calculation freq = 13.066300 Hz, v_amp = 0.000652 V, v_ph = -165.708000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000022 T, THsp = 165.708000 deg 11:09:24 Move Stage, position = 1.100000 11:09:25 Stage Position Measurement, pos = 1.100000 m 11:09:27 Magnet Current, Imag = 36.4926 A Vtrans = 2.919406 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:09:46 Coil Voltage Measurement meas_freq = 13.069200 Hz, meas_v_mag = 0.000434 V, meas_v_ph = -77.802000 deg freq = 13.069200 Hz, v_amp = 0.000614 V, v_ph = -167.802000 deg 11:09:47 Transverse Field Calculation freq = 13.069200 Hz, v_amp = 0.000614 V, v_ph = -167.802000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000020 T, THsp = 167.802000 deg 11:10:02 Move Stage, position = 1.150000 11:10:03 Stage Position Measurement, pos = 1.150000 m 11:10:05 Magnet Current, Imag = 36.4912 A Vtrans = 2.919294 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:10:24 Coil Voltage Measurement meas_freq = 13.073900 Hz, meas_v_mag = 0.000517 V, meas_v_ph = -102.420000 deg freq = 13.073900 Hz, v_amp = 0.000731 V, v_ph = 167.580000 deg 11:10:24 Transverse Field Calculation freq = 13.073900 Hz, v_amp = 0.000731 V, v_ph = 167.580000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000024 T, THsp = -167.580000 deg 11:10:40 Move Stage, position = 1.200000 11:10:41 Stage Position Measurement, pos = 1.200000 m 11:10:42 Magnet Current, Imag = 36.4898 A Vtrans = 2.919180 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:11:03 Coil Voltage Measurement meas_freq = 13.068700 Hz, meas_v_mag = 0.000618 V, meas_v_ph = -114.552000 deg freq = 13.068700 Hz, v_amp = 0.000874 V, v_ph = 155.448000 deg 11:11:03 Transverse Field Calculation freq = 13.068700 Hz, v_amp = 0.000874 V, v_ph = 155.448000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000029 T, THsp = -155.448000 deg 11:11:18 Move Stage, position = 1.250000 11:11:20 Stage Position Measurement, pos = 1.250000 m 11:11:21 Magnet Current, Imag = 36.4878 A Vtrans = 2.919026 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:11:41 Coil Voltage Measurement meas_freq = 13.070100 Hz, meas_v_mag = 0.000724 V, meas_v_ph = -119.100000 deg freq = 13.070100 Hz, v_amp = 0.001023 V, v_ph = 150.900000 deg 11:11:41 Transverse Field Calculation freq = 13.070100 Hz, v_amp = 0.001023 V, v_ph = 150.900000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000034 T, THsp = -150.900000 deg 11:11:56 Move Stage, position = 1.300000 11:11:58 Stage Position Measurement, pos = 1.300000 m 11:11:59 Magnet Current, Imag = 36.4866 A Vtrans = 2.918924 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:12:18 Coil Voltage Measurement meas_freq = 13.063000 Hz, meas_v_mag = 0.000784 V, meas_v_ph = -116.916000 deg freq = 13.063000 Hz, v_amp = 0.001108 V, v_ph = 153.084000 deg 11:12:18 Transverse Field Calculation freq = 13.063000 Hz, v_amp = 0.001108 V, v_ph = 153.084000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000037 T, THsp = -153.084000 deg 11:12:34 Move Stage, position = 1.350000 11:12:35 Stage Position Measurement, pos = 1.350000 m 11:12:36 Magnet Current, Imag = 36.4845 A Vtrans = 2.918758 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:12:55 Coil Voltage Measurement meas_freq = 13.065300 Hz, meas_v_mag = 0.000784 V, meas_v_ph = -110.478000 deg freq = 13.065300 Hz, v_amp = 0.001109 V, v_ph = 159.522000 deg 11:12:56 Transverse Field Calculation freq = 13.065300 Hz, v_amp = 0.001109 V, v_ph = 159.522000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000037 T, THsp = -159.522000 deg 11:13:11 Move Stage, position = 1.400000 11:13:12 Stage Position Measurement, pos = 1.400000 m 11:13:13 Magnet Current, Imag = 36.4834 A Vtrans = 2.918671 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:13:33 Coil Voltage Measurement meas_freq = 13.064900 Hz, meas_v_mag = 0.000795 V, meas_v_ph = -104.466000 deg freq = 13.064900 Hz, v_amp = 0.001124 V, v_ph = 165.534000 deg 11:13:33 Transverse Field Calculation freq = 13.064900 Hz, v_amp = 0.001124 V, v_ph = 165.534000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000038 T, THsp = -165.534000 deg 11:13:48 Move Stage, position = 1.450000 11:13:49 Stage Position Measurement, pos = 1.450000 m 11:13:51 Magnet Current, Imag = 36.4821 A Vtrans = 2.918572 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:14:10 Coil Voltage Measurement meas_freq = 13.068700 Hz, meas_v_mag = 0.000792 V, meas_v_ph = -100.632000 deg freq = 13.068700 Hz, v_amp = 0.001120 V, v_ph = 169.368000 deg 11:14:10 Transverse Field Calculation freq = 13.068700 Hz, v_amp = 0.001120 V, v_ph = 169.368000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000037 T, THsp = -169.368000 deg 11:14:25 Move Stage, position = 1.500000 11:14:27 Stage Position Measurement, pos = 1.500000 m 11:14:28 Magnet Current, Imag = 36.4817 A Vtrans = 2.918534 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:14:48 Coil Voltage Measurement meas_freq = 13.071100 Hz, meas_v_mag = 0.000767 V, meas_v_ph = -100.788000 deg freq = 13.071100 Hz, v_amp = 0.001085 V, v_ph = 169.212000 deg 11:14:48 Transverse Field Calculation freq = 13.071100 Hz, v_amp = 0.001085 V, v_ph = 169.212000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000036 T, THsp = -169.212000 deg 11:15:03 Move Stage, position = 1.550000 11:15:05 Stage Position Measurement, pos = 1.550000 m 11:15:06 Magnet Current, Imag = 36.4809 A Vtrans = 2.918469 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:15:26 Coil Voltage Measurement meas_freq = 13.073900 Hz, meas_v_mag = 0.000708 V, meas_v_ph = -105.210000 deg freq = 13.073900 Hz, v_amp = 0.001002 V, v_ph = 164.790000 deg 11:15:26 Transverse Field Calculation freq = 13.073900 Hz, v_amp = 0.001002 V, v_ph = 164.790000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000033 T, THsp = -164.790000 deg 11:15:42 Move Stage, position = 1.600000 11:15:43 Stage Position Measurement, pos = 1.600000 m 11:15:44 Magnet Current, Imag = 36.4795 A Vtrans = 2.918359 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:16:05 Coil Voltage Measurement meas_freq = 13.067200 Hz, meas_v_mag = 0.000630 V, meas_v_ph = -102.912000 deg freq = 13.067200 Hz, v_amp = 0.000891 V, v_ph = 167.088000 deg 11:16:05 Transverse Field Calculation freq = 13.067200 Hz, v_amp = 0.000891 V, v_ph = 167.088000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000030 T, THsp = -167.088000 deg 11:16:20 Move Stage, position = 1.650000 11:16:22 Stage Position Measurement, pos = 1.650000 m 11:16:23 Magnet Current, Imag = 36.4783 A Vtrans = 2.918267 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:16:43 Coil Voltage Measurement meas_freq = 13.068200 Hz, meas_v_mag = 0.000573 V, meas_v_ph = -96.624000 deg freq = 13.068200 Hz, v_amp = 0.000810 V, v_ph = 173.376000 deg 11:16:43 Transverse Field Calculation freq = 13.068200 Hz, v_amp = 0.000810 V, v_ph = 173.376000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000027 T, THsp = -173.376000 deg 11:16:58 Move Stage, position = 1.700000 11:17:00 Stage Position Measurement, pos = 1.700000 m 11:17:01 Magnet Current, Imag = 36.4769 A Vtrans = 2.918149 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:17:34 Coil Voltage Measurement meas_freq = 13.071100 Hz, meas_v_mag = 0.000542 V, meas_v_ph = -84.804000 deg freq = 13.071100 Hz, v_amp = 0.000767 V, v_ph = -174.804000 deg 11:17:34 Transverse Field Calculation freq = 13.071100 Hz, v_amp = 0.000767 V, v_ph = -174.804000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000026 T, THsp = 174.804000 deg 11:17:49 Move Stage, position = 1.750000 11:17:51 Stage Position Measurement, pos = 1.750000 m 11:17:52 Magnet Current, Imag = 36.4751 A Vtrans = 2.918009 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:18:13 Coil Voltage Measurement meas_freq = 13.072000 Hz, meas_v_mag = 0.000565 V, meas_v_ph = -67.848000 deg freq = 13.072000 Hz, v_amp = 0.000800 V, v_ph = -157.848000 deg 11:18:13 Transverse Field Calculation freq = 13.072000 Hz, v_amp = 0.000800 V, v_ph = -157.848000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000027 T, THsp = 157.848000 deg 11:18:28 Move Stage, position = 1.800000 11:18:29 Stage Position Measurement, pos = 1.800000 m 11:18:31 Magnet Current, Imag = 36.4744 A Vtrans = 2.917951 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:18:51 Coil Voltage Measurement meas_freq = 13.070600 Hz, meas_v_mag = 0.000586 V, meas_v_ph = -52.632000 deg freq = 13.070600 Hz, v_amp = 0.000828 V, v_ph = -142.632000 deg 11:18:51 Transverse Field Calculation freq = 13.070600 Hz, v_amp = 0.000828 V, v_ph = -142.632000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000028 T, THsp = 142.632000 deg 11:19:06 Move Stage, position = 1.850000 11:19:08 Stage Position Measurement, pos = 1.850000 m 11:19:09 Magnet Current, Imag = 36.4735 A Vtrans = 2.917882 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:19:29 Coil Voltage Measurement meas_freq = 13.066800 Hz, meas_v_mag = 0.000605 V, meas_v_ph = -37.104000 deg freq = 13.066800 Hz, v_amp = 0.000856 V, v_ph = -127.104000 deg 11:19:29 Transverse Field Calculation freq = 13.066800 Hz, v_amp = 0.000856 V, v_ph = -127.104000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000029 T, THsp = 127.104000 deg 11:25:45 Move Stage, position = 0.000000 11:25:46 Magnet current ramping to 0.0000 A...