SLAC Magnetic Measurements Date: 03-05-2003 Time: 15:15:42 Project: Klystron Magnet Type: Solenoid Magnet Name: PEPII-SN103 Serial Number: Run Number: 12 Measurement Device: Coil 2 Operator: zw Comment: Bt vs z, I2-11 = 0 A, I12 = 0 A Test Currents (A): 0.0 15:15:57 Btcoil, device being used, type = SR850 15:16:08 Stage Zeroed 15:16:08 MoveZ Devices: Move Device = SXDRIVE, Read Device = SXDRIVE 15:16:09 Initial Zero Current Measurement, Imag_zero = 0.0000 A 15:16:09 Magnet current ramping to 0.0000 A... 15:16:28 Move Stage, position = -0.050000 15:16:30 Stage Position Measurement, pos = -0.050000 m 15:16:32 Magnet Current, Imag = -0.0034 A Vtrans = -0.000268 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:16:56 Coil Voltage Measurement meas_freq = 13.091600 Hz, meas_v_mag = 0.000129 V, meas_v_ph = 97.536000 deg freq = 13.091600 Hz, v_amp = 0.000182 V, v_ph = 7.536000 deg 15:16:56 Transverse Field Calculation freq = 13.091600 Hz, v_amp = 0.000182 V, v_ph = 7.536000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000006 T, THsp = -7.536000 deg 15:17:11 Move Stage, position = 0.000000 15:17:13 Stage Position Measurement, pos = 0.000000 m 15:17:15 Magnet Current, Imag = -0.0034 A Vtrans = -0.000270 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:17:38 Coil Voltage Measurement meas_freq = 13.088700 Hz, meas_v_mag = 0.000166 V, meas_v_ph = 61.878000 deg freq = 13.088700 Hz, v_amp = 0.000235 V, v_ph = -28.122000 deg 15:17:38 Transverse Field Calculation freq = 13.088700 Hz, v_amp = 0.000235 V, v_ph = -28.122000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000008 T, THsp = 28.122000 deg 15:17:53 Move Stage, position = 0.050000 15:17:55 Stage Position Measurement, pos = 0.050000 m 15:17:56 Magnet Current, Imag = -0.0034 A Vtrans = -0.000269 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:18:20 Coil Voltage Measurement meas_freq = 13.085400 Hz, meas_v_mag = 0.000120 V, meas_v_ph = 70.962000 deg freq = 13.085400 Hz, v_amp = 0.000169 V, v_ph = -19.038000 deg 15:18:20 Transverse Field Calculation freq = 13.085400 Hz, v_amp = 0.000169 V, v_ph = -19.038000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000006 T, THsp = 19.038000 deg 15:18:35 Move Stage, position = 0.100000 15:18:37 Stage Position Measurement, pos = 0.100000 m 15:18:39 Magnet Current, Imag = -0.0034 A Vtrans = -0.000270 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:19:02 Coil Voltage Measurement meas_freq = 13.085400 Hz, meas_v_mag = 0.000097 V, meas_v_ph = 94.380000 deg freq = 13.085400 Hz, v_amp = 0.000136 V, v_ph = 4.380000 deg 15:19:02 Transverse Field Calculation freq = 13.085400 Hz, v_amp = 0.000136 V, v_ph = 4.380000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000005 T, THsp = -4.380000 deg 15:19:17 Move Stage, position = 0.150000 15:19:19 Stage Position Measurement, pos = 0.150000 m 15:19:21 Magnet Current, Imag = -0.0034 A Vtrans = -0.000271 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:19:44 Coil Voltage Measurement meas_freq = 13.083500 Hz, meas_v_mag = 0.000107 V, meas_v_ph = 111.336000 deg freq = 13.083500 Hz, v_amp = 0.000152 V, v_ph = 21.336000 deg 15:19:44 Transverse Field Calculation freq = 13.083500 Hz, v_amp = 0.000152 V, v_ph = 21.336000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000005 T, THsp = -21.336000 deg 15:19:59 Move Stage, position = 0.200000 15:20:01 Stage Position Measurement, pos = 0.200000 m 15:20:03 Magnet Current, Imag = -0.0034 A Vtrans = -0.000272 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:20:27 Coil Voltage Measurement meas_freq = 13.084900 Hz, meas_v_mag = 0.000122 V, meas_v_ph = 121.638000 deg freq = 13.084900 Hz, v_amp = 0.000173 V, v_ph = 31.638000 deg 15:20:27 Transverse Field Calculation freq = 13.084900 Hz, v_amp = 0.000173 V, v_ph = 31.638000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000006 T, THsp = -31.638000 deg 15:20:42 Move Stage, position = 0.250000 15:20:43 Stage Position Measurement, pos = 0.250000 m 15:20:45 Magnet Current, Imag = -0.0034 A Vtrans = -0.000271 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:21:09 Coil Voltage Measurement meas_freq = 13.082000 Hz, meas_v_mag = 0.000137 V, meas_v_ph = 132.762000 deg freq = 13.082000 Hz, v_amp = 0.000194 V, v_ph = 42.762000 deg 15:21:09 Transverse Field Calculation freq = 13.082000 Hz, v_amp = 0.000194 V, v_ph = 42.762000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000006 T, THsp = -42.762000 deg 15:21:24 Move Stage, position = 0.300000 15:21:26 Stage Position Measurement, pos = 0.300000 m 15:21:28 Magnet Current, Imag = -0.0034 A Vtrans = -0.000272 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:22:07 Coil Voltage Measurement meas_freq = 13.078200 Hz, meas_v_mag = 0.000147 V, meas_v_ph = 139.056000 deg freq = 13.078200 Hz, v_amp = 0.000208 V, v_ph = 49.056000 deg 15:22:07 Transverse Field Calculation freq = 13.078200 Hz, v_amp = 0.000208 V, v_ph = 49.056000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000007 T, THsp = -49.056000 deg 15:22:22 Move Stage, position = 0.350000 15:22:24 Stage Position Measurement, pos = 0.350000 m 15:22:25 Magnet Current, Imag = -0.0034 A Vtrans = -0.000271 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:22:48 Coil Voltage Measurement meas_freq = 13.082000 Hz, meas_v_mag = 0.000152 V, meas_v_ph = 143.328000 deg freq = 13.082000 Hz, v_amp = 0.000216 V, v_ph = 53.328000 deg 15:22:48 Transverse Field Calculation freq = 13.082000 Hz, v_amp = 0.000216 V, v_ph = 53.328000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000007 T, THsp = -53.328000 deg 15:23:03 Move Stage, position = 0.400000 15:23:05 Stage Position Measurement, pos = 0.400000 m 15:23:07 Magnet Current, Imag = -0.0034 A Vtrans = -0.000272 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:23:31 Coil Voltage Measurement meas_freq = 13.080100 Hz, meas_v_mag = 0.000158 V, meas_v_ph = 146.772000 deg freq = 13.080100 Hz, v_amp = 0.000223 V, v_ph = 56.772000 deg 15:23:31 Transverse Field Calculation freq = 13.080100 Hz, v_amp = 0.000223 V, v_ph = 56.772000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000007 T, THsp = -56.772000 deg 15:23:46 Move Stage, position = 0.450000 15:23:47 Stage Position Measurement, pos = 0.450000 m 15:23:49 Magnet Current, Imag = -0.0034 A Vtrans = -0.000272 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:24:12 Coil Voltage Measurement meas_freq = 13.083500 Hz, meas_v_mag = 0.000158 V, meas_v_ph = 148.854000 deg freq = 13.083500 Hz, v_amp = 0.000224 V, v_ph = 58.854000 deg 15:24:12 Transverse Field Calculation freq = 13.083500 Hz, v_amp = 0.000224 V, v_ph = 58.854000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000007 T, THsp = -58.854000 deg 15:24:27 Move Stage, position = 0.500000 15:24:29 Stage Position Measurement, pos = 0.500000 m 15:24:30 Magnet Current, Imag = -0.0034 A Vtrans = -0.000272 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:24:53 Coil Voltage Measurement meas_freq = 13.081100 Hz, meas_v_mag = 0.000158 V, meas_v_ph = 148.728000 deg freq = 13.081100 Hz, v_amp = 0.000224 V, v_ph = 58.728000 deg 15:24:53 Transverse Field Calculation freq = 13.081100 Hz, v_amp = 0.000224 V, v_ph = 58.728000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000007 T, THsp = -58.728000 deg 15:25:08 Move Stage, position = 0.550000 15:25:10 Stage Position Measurement, pos = 0.550000 m 15:25:12 Magnet Current, Imag = -0.0034 A Vtrans = -0.000271 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:25:34 Coil Voltage Measurement meas_freq = 13.079600 Hz, meas_v_mag = 0.000157 V, meas_v_ph = 149.496000 deg freq = 13.079600 Hz, v_amp = 0.000222 V, v_ph = 59.496000 deg 15:25:35 Transverse Field Calculation freq = 13.079600 Hz, v_amp = 0.000222 V, v_ph = 59.496000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000007 T, THsp = -59.496000 deg 15:25:50 Move Stage, position = 0.600000 15:25:51 Stage Position Measurement, pos = 0.600000 m 15:25:53 Magnet Current, Imag = -0.0034 A Vtrans = -0.000272 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:26:16 Coil Voltage Measurement meas_freq = 13.082000 Hz, meas_v_mag = 0.000158 V, meas_v_ph = 150.936000 deg freq = 13.082000 Hz, v_amp = 0.000223 V, v_ph = 60.936000 deg 15:26:16 Transverse Field Calculation freq = 13.082000 Hz, v_amp = 0.000223 V, v_ph = 60.936000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000007 T, THsp = -60.936000 deg 15:26:31 Move Stage, position = 0.650000 15:26:33 Stage Position Measurement, pos = 0.650000 m 15:26:34 Magnet Current, Imag = -0.0034 A Vtrans = -0.000271 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:26:57 Coil Voltage Measurement meas_freq = 13.078700 Hz, meas_v_mag = 0.000156 V, meas_v_ph = 149.556000 deg freq = 13.078700 Hz, v_amp = 0.000221 V, v_ph = 59.556000 deg 15:26:57 Transverse Field Calculation freq = 13.078700 Hz, v_amp = 0.000221 V, v_ph = 59.556000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000007 T, THsp = -59.556000 deg 15:27:12 Move Stage, position = 0.700000 15:27:14 Stage Position Measurement, pos = 0.700000 m 15:27:16 Magnet Current, Imag = -0.0034 A Vtrans = -0.000272 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:27:39 Coil Voltage Measurement meas_freq = 13.078200 Hz, meas_v_mag = 0.000158 V, meas_v_ph = 149.946000 deg freq = 13.078200 Hz, v_amp = 0.000223 V, v_ph = 59.946000 deg 15:27:39 Transverse Field Calculation freq = 13.078200 Hz, v_amp = 0.000223 V, v_ph = 59.946000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000007 T, THsp = -59.946000 deg 15:27:54 Move Stage, position = 0.750000 15:27:56 Stage Position Measurement, pos = 0.750000 m 15:27:57 Magnet Current, Imag = -0.0034 A Vtrans = -0.000272 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:28:20 Coil Voltage Measurement meas_freq = 13.077300 Hz, meas_v_mag = 0.000159 V, meas_v_ph = 149.922000 deg freq = 13.077300 Hz, v_amp = 0.000225 V, v_ph = 59.922000 deg 15:28:20 Transverse Field Calculation freq = 13.077300 Hz, v_amp = 0.000225 V, v_ph = 59.922000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000008 T, THsp = -59.922000 deg 15:28:35 Move Stage, position = 0.800000 15:28:37 Stage Position Measurement, pos = 0.800000 m 15:28:39 Magnet Current, Imag = -0.0034 A Vtrans = -0.000272 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:29:01 Coil Voltage Measurement meas_freq = 13.075800 Hz, meas_v_mag = 0.000164 V, meas_v_ph = 150.372000 deg freq = 13.075800 Hz, v_amp = 0.000232 V, v_ph = 60.372000 deg 15:29:01 Transverse Field Calculation freq = 13.075800 Hz, v_amp = 0.000232 V, v_ph = 60.372000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000008 T, THsp = -60.372000 deg 15:29:17 Move Stage, position = 0.850000 15:29:18 Stage Position Measurement, pos = 0.850000 m 15:29:20 Magnet Current, Imag = -0.0034 A Vtrans = -0.000272 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:29:43 Coil Voltage Measurement meas_freq = 13.071500 Hz, meas_v_mag = 0.000172 V, meas_v_ph = 151.896000 deg freq = 13.071500 Hz, v_amp = 0.000243 V, v_ph = 61.896000 deg 15:29:43 Transverse Field Calculation freq = 13.071500 Hz, v_amp = 0.000243 V, v_ph = 61.896000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000008 T, THsp = -61.896000 deg 15:29:58 Move Stage, position = 0.900000 15:30:00 Stage Position Measurement, pos = 0.900000 m 15:30:01 Magnet Current, Imag = -0.0034 A Vtrans = -0.000272 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:30:39 Coil Voltage Measurement meas_freq = 13.070100 Hz, meas_v_mag = 0.000179 V, meas_v_ph = 153.720000 deg freq = 13.070100 Hz, v_amp = 0.000254 V, v_ph = 63.720000 deg 15:30:39 Transverse Field Calculation freq = 13.070100 Hz, v_amp = 0.000254 V, v_ph = 63.720000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000008 T, THsp = -63.720000 deg 15:30:55 Move Stage, position = 0.950000 15:30:56 Stage Position Measurement, pos = 0.950000 m 15:30:58 Magnet Current, Imag = -0.0034 A Vtrans = -0.000272 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:31:21 Coil Voltage Measurement meas_freq = 13.075800 Hz, meas_v_mag = 0.000189 V, meas_v_ph = 155.694000 deg freq = 13.075800 Hz, v_amp = 0.000267 V, v_ph = 65.694000 deg 15:31:21 Transverse Field Calculation freq = 13.075800 Hz, v_amp = 0.000267 V, v_ph = 65.694000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000009 T, THsp = -65.694000 deg 15:31:36 Move Stage, position = 1.000000 15:31:38 Stage Position Measurement, pos = 1.000000 m 15:31:39 Magnet Current, Imag = -0.0034 A Vtrans = -0.000273 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:32:03 Coil Voltage Measurement meas_freq = 13.085800 Hz, meas_v_mag = 0.000198 V, meas_v_ph = 157.224000 deg freq = 13.085800 Hz, v_amp = 0.000280 V, v_ph = 67.224000 deg 15:32:03 Transverse Field Calculation freq = 13.085800 Hz, v_amp = 0.000280 V, v_ph = 67.224000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000009 T, THsp = -67.224000 deg 15:32:18 Move Stage, position = 1.050000 15:32:20 Stage Position Measurement, pos = 1.050000 m 15:32:22 Magnet Current, Imag = -0.0034 A Vtrans = -0.000272 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:32:44 Coil Voltage Measurement meas_freq = 13.080600 Hz, meas_v_mag = 0.000208 V, meas_v_ph = 158.382000 deg freq = 13.080600 Hz, v_amp = 0.000294 V, v_ph = 68.382000 deg 15:32:44 Transverse Field Calculation freq = 13.080600 Hz, v_amp = 0.000294 V, v_ph = 68.382000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000010 T, THsp = -68.382000 deg 15:32:59 Move Stage, position = 1.100000 15:33:01 Stage Position Measurement, pos = 1.100000 m 15:33:03 Magnet Current, Imag = -0.0034 A Vtrans = -0.000273 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:33:26 Coil Voltage Measurement meas_freq = 13.083900 Hz, meas_v_mag = 0.000218 V, meas_v_ph = 159.726000 deg freq = 13.083900 Hz, v_amp = 0.000308 V, v_ph = 69.726000 deg 15:33:26 Transverse Field Calculation freq = 13.083900 Hz, v_amp = 0.000308 V, v_ph = 69.726000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000010 T, THsp = -69.726000 deg 15:33:41 Move Stage, position = 1.150000 15:33:43 Stage Position Measurement, pos = 1.150000 m 15:33:45 Magnet Current, Imag = -0.0034 A Vtrans = -0.000272 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:34:07 Coil Voltage Measurement meas_freq = 13.083900 Hz, meas_v_mag = 0.000228 V, meas_v_ph = 161.808000 deg freq = 13.083900 Hz, v_amp = 0.000323 V, v_ph = 71.808000 deg 15:34:07 Transverse Field Calculation freq = 13.083900 Hz, v_amp = 0.000323 V, v_ph = 71.808000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000011 T, THsp = -71.808000 deg 15:34:22 Move Stage, position = 1.200000 15:34:24 Stage Position Measurement, pos = 1.200000 m 15:34:26 Magnet Current, Imag = -0.0034 A Vtrans = -0.000272 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:34:49 Coil Voltage Measurement meas_freq = 13.082500 Hz, meas_v_mag = 0.000237 V, meas_v_ph = 166.230000 deg freq = 13.082500 Hz, v_amp = 0.000335 V, v_ph = 76.230000 deg 15:34:49 Transverse Field Calculation freq = 13.082500 Hz, v_amp = 0.000335 V, v_ph = 76.230000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000011 T, THsp = -76.230000 deg 15:35:04 Move Stage, position = 1.250000 15:35:06 Stage Position Measurement, pos = 1.250000 m 15:35:07 Magnet Current, Imag = -0.0034 A Vtrans = -0.000272 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:35:31 Coil Voltage Measurement meas_freq = 13.085400 Hz, meas_v_mag = 0.000242 V, meas_v_ph = 168.486000 deg freq = 13.085400 Hz, v_amp = 0.000343 V, v_ph = 78.486000 deg 15:35:31 Transverse Field Calculation freq = 13.085400 Hz, v_amp = 0.000343 V, v_ph = 78.486000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000011 T, THsp = -78.486000 deg 15:35:46 Move Stage, position = 1.300000 15:35:47 Stage Position Measurement, pos = 1.300000 m 15:35:49 Magnet Current, Imag = -0.0034 A Vtrans = -0.000272 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:36:12 Coil Voltage Measurement meas_freq = 13.080100 Hz, meas_v_mag = 0.000248 V, meas_v_ph = 170.394000 deg freq = 13.080100 Hz, v_amp = 0.000351 V, v_ph = 80.394000 deg 15:36:12 Transverse Field Calculation freq = 13.080100 Hz, v_amp = 0.000351 V, v_ph = 80.394000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000012 T, THsp = -80.394000 deg 15:36:27 Move Stage, position = 1.350000 15:36:29 Stage Position Measurement, pos = 1.350000 m 15:36:31 Magnet Current, Imag = -0.0034 A Vtrans = -0.000271 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:36:55 Coil Voltage Measurement meas_freq = 13.080600 Hz, meas_v_mag = 0.000251 V, meas_v_ph = 172.104000 deg freq = 13.080600 Hz, v_amp = 0.000356 V, v_ph = 82.104000 deg 15:36:55 Transverse Field Calculation freq = 13.080600 Hz, v_amp = 0.000356 V, v_ph = 82.104000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000012 T, THsp = -82.104000 deg 15:37:10 Move Stage, position = 1.400000 15:37:11 Stage Position Measurement, pos = 1.400000 m 15:37:13 Magnet Current, Imag = -0.0034 A Vtrans = -0.000272 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:37:36 Coil Voltage Measurement meas_freq = 13.078700 Hz, meas_v_mag = 0.000251 V, meas_v_ph = 175.824000 deg freq = 13.078700 Hz, v_amp = 0.000356 V, v_ph = 85.824000 deg 15:37:36 Transverse Field Calculation freq = 13.078700 Hz, v_amp = 0.000356 V, v_ph = 85.824000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000012 T, THsp = -85.824000 deg 15:37:51 Move Stage, position = 1.450000 15:37:53 Stage Position Measurement, pos = 1.450000 m 15:37:55 Magnet Current, Imag = -0.0034 A Vtrans = -0.000271 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:38:33 Coil Voltage Measurement meas_freq = 13.078700 Hz, meas_v_mag = 0.000254 V, meas_v_ph = 180.000000 deg freq = 13.078700 Hz, v_amp = 0.000359 V, v_ph = 90.000000 deg 15:38:33 Transverse Field Calculation freq = 13.078700 Hz, v_amp = 0.000359 V, v_ph = 90.000000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000012 T, THsp = -90.000000 deg 15:38:48 Move Stage, position = 1.500000 15:38:49 Stage Position Measurement, pos = 1.500000 m 15:38:51 Magnet Current, Imag = -0.0034 A Vtrans = -0.000271 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:39:15 Coil Voltage Measurement meas_freq = 13.081600 Hz, meas_v_mag = 0.000254 V, meas_v_ph = -176.286000 deg freq = 13.081600 Hz, v_amp = 0.000360 V, v_ph = 93.714000 deg 15:39:15 Transverse Field Calculation freq = 13.081600 Hz, v_amp = 0.000360 V, v_ph = 93.714000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000012 T, THsp = -93.714000 deg 15:39:32 Move Stage, position = 1.550000 15:39:33 Stage Position Measurement, pos = 1.550000 m 15:39:35 Magnet Current, Imag = -0.0034 A Vtrans = -0.000271 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:39:59 Coil Voltage Measurement meas_freq = 13.091600 Hz, meas_v_mag = 0.000257 V, meas_v_ph = -171.768000 deg freq = 13.091600 Hz, v_amp = 0.000363 V, v_ph = 98.232000 deg 15:39:59 Transverse Field Calculation freq = 13.091600 Hz, v_amp = 0.000363 V, v_ph = 98.232000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000012 T, THsp = -98.232000 deg 15:40:14 Move Stage, position = 1.600000 15:40:16 Stage Position Measurement, pos = 1.600000 m 15:40:18 Magnet Current, Imag = -0.0034 A Vtrans = -0.000272 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:40:41 Coil Voltage Measurement meas_freq = 13.084900 Hz, meas_v_mag = 0.000259 V, meas_v_ph = -167.844000 deg freq = 13.084900 Hz, v_amp = 0.000366 V, v_ph = 102.156000 deg 15:40:41 Transverse Field Calculation freq = 13.084900 Hz, v_amp = 0.000366 V, v_ph = 102.156000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000012 T, THsp = -102.156000 deg 15:40:56 Move Stage, position = 1.650000 15:40:58 Stage Position Measurement, pos = 1.650000 m 15:41:00 Magnet Current, Imag = -0.0034 A Vtrans = -0.000272 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:41:23 Coil Voltage Measurement meas_freq = 13.087700 Hz, meas_v_mag = 0.000261 V, meas_v_ph = -163.278000 deg freq = 13.087700 Hz, v_amp = 0.000369 V, v_ph = 106.722000 deg 15:41:23 Transverse Field Calculation freq = 13.087700 Hz, v_amp = 0.000369 V, v_ph = 106.722000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000012 T, THsp = -106.722000 deg 15:41:38 Move Stage, position = 1.700000 15:41:39 Stage Position Measurement, pos = 1.700000 m 15:41:41 Magnet Current, Imag = -0.0034 A Vtrans = -0.000271 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:42:04 Coil Voltage Measurement meas_freq = 13.091100 Hz, meas_v_mag = 0.000268 V, meas_v_ph = -158.754000 deg freq = 13.091100 Hz, v_amp = 0.000379 V, v_ph = 111.246000 deg 15:42:04 Transverse Field Calculation freq = 13.091100 Hz, v_amp = 0.000379 V, v_ph = 111.246000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000013 T, THsp = -111.246000 deg 15:42:20 Move Stage, position = 1.750000 15:42:21 Stage Position Measurement, pos = 1.750000 m 15:42:23 Magnet Current, Imag = -0.0034 A Vtrans = -0.000271 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:42:46 Coil Voltage Measurement meas_freq = 13.089700 Hz, meas_v_mag = 0.000269 V, meas_v_ph = -155.592000 deg freq = 13.089700 Hz, v_amp = 0.000381 V, v_ph = 114.408000 deg 15:42:46 Transverse Field Calculation freq = 13.089700 Hz, v_amp = 0.000381 V, v_ph = 114.408000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000013 T, THsp = -114.408000 deg 15:43:01 Move Stage, position = 1.800000 15:43:03 Stage Position Measurement, pos = 1.800000 m 15:43:05 Magnet Current, Imag = -0.0034 A Vtrans = -0.000271 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:43:27 Coil Voltage Measurement meas_freq = 13.084400 Hz, meas_v_mag = 0.000277 V, meas_v_ph = -151.950000 deg freq = 13.084400 Hz, v_amp = 0.000392 V, v_ph = 118.050000 deg 15:43:28 Transverse Field Calculation freq = 13.084400 Hz, v_amp = 0.000392 V, v_ph = 118.050000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000013 T, THsp = -118.050000 deg 15:43:43 Move Stage, position = 1.850000 15:43:44 Stage Position Measurement, pos = 1.850000 m 15:43:46 Magnet Current, Imag = -0.0034 A Vtrans = -0.000272 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:44:09 Coil Voltage Measurement meas_freq = 13.094400 Hz, meas_v_mag = 0.000281 V, meas_v_ph = -147.870000 deg freq = 13.094400 Hz, v_amp = 0.000398 V, v_ph = 122.130000 deg 15:44:09 Transverse Field Calculation freq = 13.094400 Hz, v_amp = 0.000398 V, v_ph = 122.130000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000013 T, THsp = -122.130000 deg 15:44:24 Move Stage, position = 1.900000 15:44:26 Stage Position Measurement, pos = 1.900000 m 15:44:28 Magnet Current, Imag = -0.0034 A Vtrans = -0.000271 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:44:51 Coil Voltage Measurement meas_freq = 13.091100 Hz, meas_v_mag = 0.000298 V, meas_v_ph = -144.360000 deg freq = 13.091100 Hz, v_amp = 0.000422 V, v_ph = 125.640000 deg 15:44:51 Transverse Field Calculation freq = 13.091100 Hz, v_amp = 0.000422 V, v_ph = 125.640000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000014 T, THsp = -125.640000 deg 15:45:06 Move Stage, position = 1.950000 15:45:08 Stage Position Measurement, pos = 1.950000 m 15:45:09 Magnet Current, Imag = -0.0034 A Vtrans = -0.000271 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:45:32 Coil Voltage Measurement meas_freq = 13.082500 Hz, meas_v_mag = 0.000305 V, meas_v_ph = -142.218000 deg freq = 13.082500 Hz, v_amp = 0.000431 V, v_ph = 127.782000 deg 15:45:32 Transverse Field Calculation freq = 13.082500 Hz, v_amp = 0.000431 V, v_ph = 127.782000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000014 T, THsp = -127.782000 deg 15:45:47 Move Stage, position = 2.000000 15:45:49 Stage Position Measurement, pos = 2.000000 m 15:45:51 Magnet Current, Imag = -0.0034 A Vtrans = -0.000272 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:46:14 Coil Voltage Measurement meas_freq = 13.085400 Hz, meas_v_mag = 0.000314 V, meas_v_ph = -140.640000 deg freq = 13.085400 Hz, v_amp = 0.000444 V, v_ph = 129.360000 deg 15:46:14 Transverse Field Calculation freq = 13.085400 Hz, v_amp = 0.000444 V, v_ph = 129.360000 deg Coil Constant = 0.033390 (T/V0p) Transverse Field, Bt = 0.000015 T, THsp = -129.360000 deg 15:53:00 Move Stage, position = 0.000000 15:53:01 Magnet current ramping to 0.0000 A...