SLAC Magnetic Measurements Date: 03-04-2010 Time: 14:33:16 Project: FACET Magnet Type: Quad Magnet Name: QS2 Serial Number: Type2.13Q38.31 Run Number: 2 Measurement Device: 10 wire Operator: sda Comment: Intgegrated Gradient using stretched wire at 475 amps for coil calibration. Standardization: 3 cycles from 10.0 A to 475.0 A to 10.0 A Test Currents (A): 475.0 475.0 475.0 Integrated Gradient Distance the wire was to be moved = 0.005000 m Number of turns in the wire = 10 Number of measurements for averaging = 6 Imag sigImag GL sigGL GL/I sigGL/I (A) (A) (T) (T) (T/A) (T/A) ---------+--------- ----------+---------- ----------+---------- 475.005 0.012 38.57035 0.00223 0.081200 0.000005 475.001 0.007 38.56770 0.00184 0.081195 0.000004 475.033 0.010 38.56944 0.00174 0.081193 0.000004