SLAC Magnetic Measurements Date: 08-25-2010 Time: 18:26:21 Project: FACET_Sector_20 Magnet Type: Quad Magnet Name: Q5E#2 Serial Number: Q202261T Run Number: 3 Measurement Device: DC34_qadd Operator: sda Comment: Coil calibration with coil not mechanically fixed. Standardization: 3 cycles from 5.0 A to 175.0 A to 5.0 A Test Currents (A): 175.0 175.0 175.0 175.0 Integrated Gradient Time Imag sigImag GL sigGL GL/I sigGL/I THsp sigTHsp (A) (T) (T/A) (deg) -------- ---------+--------- ----------+---------- ----------+---------- ----------+---------- 18:35:45 175.08084 0.00029 14.017494 0.000006 0.080063 1.683e-07 -46.9297 0.000081 18:42:50 175.08043 0.00029 14.017414 0.000036 0.0800627 3.366e-07 -46.9296 0.000089 18:46:40 175.08076 0.00022 14.017448 0.000014 0.0800628 1.827e-07 -46.9295 0.000073 18:50:30 175.08073 0.00028 14.017462 0.000028 0.0800628 2.877e-07 -46.9294 0.000073