SLAC Magnetic Measurements Date: 10-27-2010 Time: 10:05:17 Project: FACET_Sector_20 Magnet Type: Quad Magnet Name: Q4E#2 Serial Number: Q202211T Run Number: 4 Measurement Device: DC55q_a Operator: sda Comment: Coil A calibration Standardization: 5 cycles from 5.0 A to 250.0 A to 5.0 A Test Currents (A): 193.6 193.6 Integrated Gradient Time Imag sigImag GL sigGL GL/I sigGL/I THsp sigTHsp (A) (T) (T/A) (deg) -------- ---------+--------- ----------+---------- ----------+---------- ----------+---------- 10:20:02 193.51421 0.00105 25.190398 0.000633 0.130173 3.978e-06 44.5774 0.004698 10:25:45 193.51418 0.00038 25.191132 0.000509 0.130177 2.884e-06 44.5706 0.002080