SLAC Magnetic Measurements Date: 09-10-2010 Time: 13:04:44 Project: FACET_Sector_20 Magnet Type: Quad Magnet Name: Q3E#3 Serial Number: Q202341T Run Number: 3 Measurement Device: DC34qadd Operator: sda Comment: Integrated gradient for coil calibration. Standardization: 3 cycles from 5.0 A to 250.0 A to 5.0 A Test Currents (A): 250.0 250.0 250.0 250.0 Integrated Gradient Time Imag sigImag GL sigGL GL/I sigGL/I THsp sigTHsp (A) (T) (T/A) (deg) -------- ---------+--------- ----------+---------- ----------+---------- ----------+---------- 13:16:08 250.03828 0.00247 32.819259 0.000047 0.131257 1.484e-06 44.8493 0.000278 13:24:24 250.03943 0.00030 32.819088 0.000064 0.131256 4.147e-07 44.8495 0.000109 13:28:54 250.03920 0.00021 32.818961 0.000056 0.131255 3.334e-07 44.8495 0.000115 13:33:23 250.03886 0.00066 32.818881 0.000022 0.131255 4.321e-07 44.8494 0.000113