SLAC Magnetic Measurements Date: 01-17-2012 Time: 08:59:15 Project: FACET_Sector_10 Magnet Type: Dipole Magnet Name: B101EP Serial Number: 1.071.4T Run Number: 6 Measurement Device: 10_wire Operator: sda Comment: INtegrated strenght at 0 amps, with power supply off after stdz, ramp to 859 A then to 0. Power supply then switched off. Test Currents for Main (A): 0.00 0.00 Integrated Field Strength Distance the wire was to be moved = 0.010000 m Number of turns in the wire = 10 Number of measurements for averaging = 4 Main +/- sigma BL sigBL BL/I sigBL/I (A) (A) (Tm) (Tm) (Tm/A) (Tm/A) ----------+---------- ------------+------------ -------------+------------- 0.0001 0.0000 0.00481022 1.7455e-06 0 0 0.0007 0.0000 0.00480337 5.43764e-06 0 0