SLAC Magnetic Measurements Date: 01-17-2012 Time: 16:31:22 Project: FACET_Sector_10 Magnet Type: Dipole Magnet Name: B101EP Serial Number: 1.071.4T Run Number: 9 Measurement Device: 10_wire Operator: sda Comment: Integrated strength. Main ps off after stdz and ramping to 859 A. Trim scan from 0 to -0.4 A. Test Currents for Main (A): 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Test Currents for Trim (A): 0.00 -0.30 -0.32 -0.34 -0.36 -0.38 -0.40 16:31:59 Magnet Current for Main, Imag = -0.0102 A Vtrans = -0.000102 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:32:00 Magnet Current for Main, Imag = -0.0103 A Vtrans = -0.000103 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:32:00 Magnet Current for Main, Imag = -0.0102 A Vtrans = -0.000102 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:32:01 Magnet Current for Main, Imag = -0.0103 A Vtrans = -0.000103 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:32:01 Magnet Avgerage Current Measurement for Main : Imag = -0.0102 +- 0.0000 A 16:32:04 Initial Zero Current Measurement for Main, Imag_zero = -0.0102496 A 16:32:05 Initial Zero Current Measurement for Trim, Imag_zero = 0 A 16:32:16 Name = None, is zeroed 16:32:16 Magnet system Main current ramping to 0.0000 A... 16:32:46 Magnet system Trim current ramping to 0.0000 A... 16:33:16 Magnetic Field Measurement Measuring the magnet strength... 16:33:16 Integrated Voltage Measurement... 16:33:17 Magnet Current for Main, Imag = -0.0001 A Vtrans = -0.000103 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010250 A 16:33:18 Magnet Current for Trim, Imag = -0.0004 A Vtrans = -0.000030 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:33:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000410953 Vs 16:33:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000423631 Vs 16:33:53 Magnet Current for Main, Imag = -0.0000 A Vtrans = -0.000103 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010250 A 16:33:54 Magnet Current for Trim, Imag = -0.0004 A Vtrans = -0.000031 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:34:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000410844 Vs 16:34:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000424755 Vs 16:34:29 Magnet Current for Main, Imag = -0.0001 A Vtrans = -0.000103 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010250 A 16:34:29 Magnet Current for Trim, Imag = -0.0004 A Vtrans = -0.000030 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:34:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000410683 Vs 16:35:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000423903 Vs 16:35:04 Magnet Current for Main, Imag = -0.0001 A Vtrans = -0.000103 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010250 A 16:35:05 Magnet Current for Trim, Imag = -0.0004 A Vtrans = -0.000031 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:35:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000411278 Vs 16:35:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000422672 Vs 16:35:39 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000417340 +- 0.000000295 Vs 16:35:39 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000417340 +- 0.000000295 Vs BL = 0.00417340 +- 0.00000295 Tm 16:35:47 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00417 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00417 0.00000 0.00417 0.00000 16:35:47 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00417 0.00000 SL = 0.0041734 +- 0.0000030 Tm^2/m^n 16:35:47 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0041734 +- 0.0000030 Tm^2/m^n 16:35:47 Magnet system Main current ramping to 0.0000 A... 16:36:17 Magnet system Trim current ramping to -0.3000 A... 16:36:48 Magnetic Field Measurement Measuring the magnet strength... 16:36:48 Integrated Voltage Measurement... 16:36:48 Magnet Current for Main, Imag = -0.0001 A Vtrans = -0.000103 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010250 A 16:36:49 Magnet Current for Trim, Imag = -0.3006 A Vtrans = -0.025051 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:37:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000054934 Vs 16:37:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000043010 Vs 16:37:25 Magnet Current for Main, Imag = -0.0002 A Vtrans = -0.000105 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010250 A 16:37:25 Magnet Current for Trim, Imag = -0.3006 A Vtrans = -0.025051 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:37:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000057715 Vs 16:38:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000045669 Vs 16:38:00 Magnet Current for Main, Imag = -0.0001 A Vtrans = -0.000104 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010250 A 16:38:01 Magnet Current for Trim, Imag = -0.3006 A Vtrans = -0.025051 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:38:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000058888 Vs 16:38:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000046480 Vs 16:38:36 Magnet Current for Main, Imag = -0.0002 A Vtrans = -0.000105 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010250 A 16:38:36 Magnet Current for Trim, Imag = -0.3006 A Vtrans = -0.025051 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:38:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000059893 Vs 16:39:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000045502 Vs 16:39:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000051511 +- 0.000001522 Vs 16:39:10 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000051511 +- 0.000001522 Vs BL = -0.00051511 +- 0.00001522 Tm 16:39:18 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00052 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.00052 0.00002 -0.00052 0.00000 16:39:18 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00052 0.00002 SL = -0.0005151 +- 0.0000152 Tm^2/m^n 16:39:18 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0005151 +- 0.0000152 Tm^2/m^n 16:39:18 Magnet system Main current ramping to 0.0000 A... 16:39:49 Magnet system Trim current ramping to -0.3200 A... 16:40:19 Magnetic Field Measurement Measuring the magnet strength... 16:40:19 Integrated Voltage Measurement... 16:40:19 Magnet Current for Main, Imag = -0.0002 A Vtrans = -0.000104 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010250 A 16:40:20 Magnet Current for Trim, Imag = -0.3006 A Vtrans = -0.025051 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:40:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000059028 Vs 16:40:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000047764 Vs 16:40:56 Magnet Current for Main, Imag = -0.0002 A Vtrans = -0.000105 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010250 A 16:40:56 Magnet Current for Trim, Imag = -0.3006 A Vtrans = -0.025052 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:41:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000058423 Vs 16:41:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000048219 Vs 16:41:31 Magnet Current for Main, Imag = -0.0002 A Vtrans = -0.000104 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010250 A 16:41:32 Magnet Current for Trim, Imag = -0.3006 A Vtrans = -0.025051 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:41:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000058867 Vs 16:42:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000049266 Vs 16:42:06 Magnet Current for Main, Imag = -0.0002 A Vtrans = -0.000104 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010250 A 16:42:07 Magnet Current for Trim, Imag = -0.3006 A Vtrans = -0.025052 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:42:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000060156 Vs 16:42:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000047546 Vs 16:42:41 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000053659 +- 0.000000311 Vs 16:42:41 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000053659 +- 0.000000311 Vs BL = -0.00053659 +- 0.00000311 Tm 16:42:49 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00054 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.00054 0.00000 -0.00054 0.00000 16:42:49 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00054 0.00000 SL = -0.0005366 +- 0.0000031 Tm^2/m^n 16:42:49 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0005366 +- 0.0000031 Tm^2/m^n 16:42:49 Magnet system Main current ramping to 0.0000 A... 16:43:20 Magnet system Trim current ramping to -0.3423 A... 16:43:50 Magnetic Field Measurement Measuring the magnet strength... 16:43:50 Integrated Voltage Measurement... 16:43:50 Magnet Current for Main, Imag = -0.0002 A Vtrans = -0.000105 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010250 A 16:43:51 Magnet Current for Trim, Imag = -0.3006 A Vtrans = -0.025051 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:44:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000058080 Vs 16:44:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000049470 Vs 16:44:27 Magnet Current for Main, Imag = -0.0002 A Vtrans = -0.000104 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010250 A 16:44:27 Magnet Current for Trim, Imag = -0.3006 A Vtrans = -0.025051 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:44:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000059158 Vs 16:45:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000048964 Vs 16:45:02 Magnet Current for Main, Imag = -0.0002 A Vtrans = -0.000104 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010250 A 16:45:03 Magnet Current for Trim, Imag = -0.3006 A Vtrans = -0.025051 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:45:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000058041 Vs 16:45:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000050063 Vs 16:45:37 Magnet Current for Main, Imag = -0.0002 A Vtrans = -0.000105 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010250 A 16:45:38 Magnet Current for Trim, Imag = -0.3006 A Vtrans = -0.025050 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:45:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000057516 Vs 16:46:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000049527 Vs 16:46:12 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000053852 +- 0.000000223 Vs 16:46:12 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000053852 +- 0.000000223 Vs BL = -0.00053852 +- 0.00000223 Tm 16:46:20 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00054 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.00054 0.00000 -0.00054 0.00000 16:46:20 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00054 0.00000 SL = -0.0005385 +- 0.0000022 Tm^2/m^n 16:46:20 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0005385 +- 0.0000022 Tm^2/m^n 16:46:20 Magnet system Main current ramping to 0.0000 A... 16:46:51 Magnet system Trim current ramping to -0.3600 A... 16:47:21 Magnetic Field Measurement Measuring the magnet strength... 16:47:21 Integrated Voltage Measurement... 16:47:22 Magnet Current for Main, Imag = -0.0002 A Vtrans = -0.000104 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010250 A 16:47:22 Magnet Current for Trim, Imag = -0.3607 A Vtrans = -0.030060 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:47:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000094351 Vs 16:47:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000173137 Vs 16:47:58 Magnet Current for Main, Imag = -0.0001 A Vtrans = -0.000103 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010250 A 16:47:58 Magnet Current for Trim, Imag = -0.3607 A Vtrans = -0.030061 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:48:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000142728 Vs 16:48:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000135003 Vs 16:48:33 Magnet Current for Main, Imag = -0.0001 A Vtrans = -0.000103 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010250 A 16:48:34 Magnet Current for Trim, Imag = -0.3607 A Vtrans = -0.030061 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:48:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000142099 Vs 16:49:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000134753 Vs 16:49:09 Magnet Current for Main, Imag = 0.0000 A Vtrans = -0.000102 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010250 A 16:49:09 Magnet Current for Trim, Imag = -0.3607 A Vtrans = -0.030060 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:49:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000143541 Vs 16:49:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000106679 Vs 16:49:44 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000134036 +- 0.000005531 Vs 16:49:44 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000134036 +- 0.000005531 Vs BL = -0.00134036 +- 0.00005531 Tm 16:49:52 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00134 0.00006 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.00134 0.00006 -0.00134 0.00000 16:49:52 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00134 0.00006 SL = -0.0013404 +- 0.0000553 Tm^2/m^n 16:49:52 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0013404 +- 0.0000553 Tm^2/m^n 16:49:52 Magnet system Main current ramping to 0.0000 A... 16:50:22 Magnet system Trim current ramping to -0.3800 A... 16:50:52 Magnetic Field Measurement Measuring the magnet strength... 16:50:52 Integrated Voltage Measurement... 16:50:53 Magnet Current for Main, Imag = -0.0002 A Vtrans = -0.000105 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010250 A 16:50:54 Magnet Current for Trim, Imag = -0.3607 A Vtrans = -0.030060 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:51:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000159647 Vs 16:51:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000145975 Vs 16:51:29 Magnet Current for Main, Imag = -0.0003 A Vtrans = -0.000105 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010250 A 16:51:30 Magnet Current for Trim, Imag = -0.3607 A Vtrans = -0.030061 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:51:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000087994 Vs 16:52:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000187768 Vs 16:52:05 Magnet Current for Main, Imag = -0.0001 A Vtrans = -0.000104 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010250 A 16:52:05 Magnet Current for Trim, Imag = -0.3607 A Vtrans = -0.030060 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:52:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000144574 Vs 16:52:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000136025 Vs 16:52:40 Magnet Current for Main, Imag = -0.0000 A Vtrans = -0.000103 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010250 A 16:52:41 Magnet Current for Trim, Imag = -0.3607 A Vtrans = -0.030062 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:52:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000146547 Vs 16:53:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000132431 Vs 16:53:15 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000142620 +- 0.000005948 Vs 16:53:15 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000142620 +- 0.000005948 Vs BL = -0.00142620 +- 0.00005948 Tm 16:53:23 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00143 0.00006 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.00143 0.00006 -0.00143 0.00000 16:53:23 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00143 0.00006 SL = -0.0014262 +- 0.0000595 Tm^2/m^n 16:53:23 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0014262 +- 0.0000595 Tm^2/m^n 16:53:23 Magnet system Main current ramping to 0.0000 A... 16:53:53 Magnet system Trim current ramping to -0.4000 A... 16:54:23 Magnetic Field Measurement Measuring the magnet strength... 16:54:23 Integrated Voltage Measurement... 16:54:24 Magnet Current for Main, Imag = -0.0002 A Vtrans = -0.000104 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010250 A 16:54:25 Magnet Current for Trim, Imag = -0.3607 A Vtrans = -0.030060 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:54:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000165058 Vs 16:55:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000148983 Vs 16:55:00 Magnet Current for Main, Imag = -0.0003 A Vtrans = -0.000105 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010250 A 16:55:01 Magnet Current for Trim, Imag = -0.3607 A Vtrans = -0.030062 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:55:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000160583 Vs 16:55:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000147751 Vs 16:55:36 Magnet Current for Main, Imag = -0.0002 A Vtrans = -0.000104 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010250 A 16:55:36 Magnet Current for Trim, Imag = -0.3607 A Vtrans = -0.030060 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:55:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000160467 Vs 16:56:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000191886 Vs 16:56:11 Magnet Current for Main, Imag = -0.0001 A Vtrans = -0.000103 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010250 A 16:56:12 Magnet Current for Trim, Imag = -0.3607 A Vtrans = -0.030060 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:56:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000139734 Vs 16:56:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000134536 Vs 16:56:46 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000156125 +- 0.000013850 Vs 16:56:46 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000156125 +- 0.000013850 Vs BL = -0.00156125 +- 0.00013850 Tm 16:56:54 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00156 0.00014 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.00156 0.00014 -0.00156 0.00000 16:56:54 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00156 0.00014 SL = -0.0015612 +- 0.0001385 Tm^2/m^n 16:56:54 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0015612 +- 0.0001385 Tm^2/m^n 16:57:05 Name = None, is zeroed 16:57:05 Magnet system Main current ramping to 0.0000 A... 16:57:05 Magnet system Trim current ramping to 0.0000 A...