SLAC Magnetic Measurements Date: 01-17-2012 Time: 14:53:09 Project: FACET_Sector_10 Magnet Type: Dipole Magnet Name: B101EP Serial Number: 1.071.4T Run Number: 8 Measurement Device: 10_wire Operator: sda Comment: Integrated strength. Main ps off after stdz and ramping to 859 A. Trim scan from 0 to -0.6 A. Standardization for Main: 3 cycles from 20.0 A to 925.0 A to 20.0 A Test Currents for Main (A): 859.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Test Currents for Trim (A): 0.00 -0.10 -0.20 -0.30 -0.32 -0.40 -0.50 -0.60 0.00 14:53:42 Magnet Current for Main, Imag = -0.0106 A Vtrans = -0.000106 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:53:43 Magnet Current for Main, Imag = -0.0105 A Vtrans = -0.000105 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:53:43 Magnet Current for Main, Imag = -0.0105 A Vtrans = -0.000105 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:53:44 Magnet Current for Main, Imag = -0.0105 A Vtrans = -0.000105 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:53:44 Magnet Avgerage Current Measurement for Main : Imag = -0.0105 +- 0.0000 A 14:54:22 Initial Zero Current Measurement for Main, Imag_zero = -0.0105281 A 14:54:22 Magnet system Main current ramping to 20.0000 A... 14:55:36 Magnet Current for Trim, Imag = 0.0003 A Vtrans = 0.000025 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 14:55:36 Magnet Current for Trim, Imag = 0.0003 A Vtrans = 0.000025 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 14:55:37 Magnet Current for Trim, Imag = 0.0003 A Vtrans = 0.000026 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 14:55:37 Magnet Current for Trim, Imag = 0.0003 A Vtrans = 0.000024 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 14:55:37 Magnet Avgerage Current Measurement for Trim : Imag = 0.0003 +- 0.0000 A 14:56:06 Initial Zero Current Measurement for Trim, Imag_zero = 0.000298785 A 14:56:06 Magnet system Main current ramping to 925.0000 A... 14:57:41 Magnet system Main current ramping to 20.0000 A... 14:59:16 Magnet system Main current ramping to 925.0000 A... 15:00:51 Magnet system Main current ramping to 20.0000 A... 15:02:26 Magnet system Main current ramping to 925.0000 A... 15:04:01 Magnet system Main current ramping to 20.0000 A... 15:05:47 Name = None, is zeroed 15:05:47 Magnet system Main current ramping to 859.0000 A... 15:08:17 Magnet system Trim current ramping to 0.0000 A... 15:08:47 Magnet system Main current ramping to 0.0000 A... 15:11:20 Magnet system Trim current ramping to -0.1000 A... 15:14:01 Magnetic Field Measurement Measuring the magnet strength... 15:14:01 Integrated Voltage Measurement... 15:14:02 Magnet Current for Main, Imag = 0.0138 A Vtrans = 0.000033 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010528 A 15:14:03 Magnet Current for Trim, Imag = -0.0998 A Vtrans = -0.008296 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000299 A 15:14:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000373476 Vs 15:14:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000384551 Vs 15:14:38 Magnet Current for Main, Imag = 0.0137 A Vtrans = 0.000032 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010528 A 15:14:39 Magnet Current for Trim, Imag = -0.0999 A Vtrans = -0.008296 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000299 A 15:14:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000373662 Vs 15:15:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000382487 Vs 15:15:14 Magnet Current for Main, Imag = 0.0137 A Vtrans = 0.000032 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010528 A 15:15:14 Magnet Current for Trim, Imag = -0.0998 A Vtrans = -0.008296 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000299 A 15:15:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000373149 Vs 15:15:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000381146 Vs 15:15:49 Magnet Current for Main, Imag = 0.0137 A Vtrans = 0.000032 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010528 A 15:15:50 Magnet Current for Trim, Imag = -0.0999 A Vtrans = -0.008296 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000299 A 15:16:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000373068 Vs 15:16:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000380091 Vs 15:16:24 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000377704 +- 0.000000925 Vs 15:16:24 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000377704 +- 0.000000925 Vs BL = 0.00377704 +- 0.00000925 Tm 15:16:32 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00378 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00378 0.00001 0.00378 0.00000 15:16:32 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00378 0.00001 SL = 0.0037770 +- 0.0000093 Tm^2/m^n 15:16:32 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0037770 +- 0.0000093 Tm^2/m^n 15:16:32 Magnet system Main current ramping to 0.0000 A... 15:17:02 Magnet system Trim current ramping to -0.2000 A... 15:17:33 Magnetic Field Measurement Measuring the magnet strength... 15:17:33 Integrated Voltage Measurement... 15:17:34 Magnet Current for Main, Imag = 0.0135 A Vtrans = 0.000030 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010528 A 15:17:34 Magnet Current for Trim, Imag = -0.1989 A Vtrans = -0.016551 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000299 A 15:17:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000220726 Vs 15:18:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000227204 Vs 15:18:10 Magnet Current for Main, Imag = 0.0137 A Vtrans = 0.000032 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010528 A 15:18:10 Magnet Current for Trim, Imag = -0.1989 A Vtrans = -0.016551 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000299 A 15:18:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000218024 Vs 15:18:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000225852 Vs 15:18:45 Magnet Current for Main, Imag = 0.0136 A Vtrans = 0.000030 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010528 A 15:18:46 Magnet Current for Trim, Imag = -0.1989 A Vtrans = -0.016551 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000299 A 15:19:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000217122 Vs 15:19:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000226076 Vs 15:19:21 Magnet Current for Main, Imag = 0.0136 A Vtrans = 0.000031 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010528 A 15:19:21 Magnet Current for Trim, Imag = -0.1989 A Vtrans = -0.016550 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000299 A 15:19:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000215797 Vs 15:19:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000226228 Vs 15:19:56 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000222129 +- 0.000001110 Vs 15:19:56 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000222129 +- 0.000001110 Vs BL = 0.00222129 +- 0.00001110 Tm 15:20:03 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00222 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00222 0.00001 0.00222 0.00000 15:20:03 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00222 0.00001 SL = 0.0022213 +- 0.0000111 Tm^2/m^n 15:20:03 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0022213 +- 0.0000111 Tm^2/m^n 15:20:03 Magnet system Main current ramping to 0.0000 A... 15:20:34 Magnet system Trim current ramping to -0.3000 A... 15:21:04 Magnetic Field Measurement Measuring the magnet strength... 15:21:04 Integrated Voltage Measurement... 15:21:05 Magnet Current for Main, Imag = 0.0137 A Vtrans = 0.000031 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010528 A 15:21:05 Magnet Current for Trim, Imag = -0.3013 A Vtrans = -0.025082 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000299 A 15:21:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000072855 Vs 15:21:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000074370 Vs 15:21:41 Magnet Current for Main, Imag = 0.0137 A Vtrans = 0.000032 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010528 A 15:21:42 Magnet Current for Trim, Imag = -0.3013 A Vtrans = -0.025083 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000299 A 15:21:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000065057 Vs 15:22:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000072899 Vs 15:22:16 Magnet Current for Main, Imag = 0.0137 A Vtrans = 0.000032 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010528 A 15:22:17 Magnet Current for Trim, Imag = -0.3013 A Vtrans = -0.025083 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000299 A 15:22:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000065312 Vs 15:22:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000070826 Vs 15:22:52 Magnet Current for Main, Imag = 0.0137 A Vtrans = 0.000031 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010528 A 15:22:53 Magnet Current for Trim, Imag = -0.3013 A Vtrans = -0.025083 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000299 A 15:23:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000064897 Vs 15:23:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000070325 Vs 15:23:27 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000069568 +- 0.000002387 Vs 15:23:27 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000069568 +- 0.000002387 Vs BL = 0.00069568 +- 0.00002387 Tm 15:23:35 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00070 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00070 0.00002 0.00070 0.00000 15:23:35 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00070 0.00002 SL = 0.0006957 +- 0.0000239 Tm^2/m^n 15:23:35 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0006957 +- 0.0000239 Tm^2/m^n 15:23:35 Magnet system Main current ramping to 0.0000 A... 15:24:05 Magnet system Trim current ramping to -0.3213 A... 15:24:35 Magnetic Field Measurement Measuring the magnet strength... 15:24:35 Integrated Voltage Measurement... 15:24:36 Magnet Current for Main, Imag = 0.0136 A Vtrans = 0.000031 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010528 A 15:24:37 Magnet Current for Trim, Imag = -0.3013 A Vtrans = -0.025083 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000299 A 15:24:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000063716 Vs 15:25:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000070742 Vs 15:25:12 Magnet Current for Main, Imag = 0.0136 A Vtrans = 0.000031 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010528 A 15:25:13 Magnet Current for Trim, Imag = -0.3013 A Vtrans = -0.025083 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000299 A 15:25:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000063394 Vs 15:25:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000115854 Vs 15:25:48 Magnet Current for Main, Imag = 0.0135 A Vtrans = 0.000030 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010528 A 15:25:48 Magnet Current for Trim, Imag = -0.3013 A Vtrans = -0.025083 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000299 A 15:26:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000005955 Vs 15:26:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000060998 Vs 15:26:23 Magnet Current for Main, Imag = 0.0135 A Vtrans = 0.000029 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010528 A 15:26:24 Magnet Current for Trim, Imag = -0.3013 A Vtrans = -0.025082 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000299 A 15:26:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000050227 Vs 15:26:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000060698 Vs 15:26:58 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000061448 +- 0.000020282 Vs 15:26:58 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000061448 +- 0.000020282 Vs BL = 0.00061448 +- 0.00020282 Tm 15:27:06 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00061 0.00020 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00061 0.00020 0.00061 0.00000 15:27:06 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00061 0.00020 SL = 0.0006145 +- 0.0002028 Tm^2/m^n 15:27:06 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0006145 +- 0.0002028 Tm^2/m^n 15:27:06 Magnet system Main current ramping to 0.0000 A... 15:27:36 Magnet system Trim current ramping to -0.4000 A... 15:28:07 Magnetic Field Measurement Measuring the magnet strength... 15:28:07 Integrated Voltage Measurement... 15:28:07 Magnet Current for Main, Imag = 0.0134 A Vtrans = 0.000029 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010528 A 15:28:08 Magnet Current for Trim, Imag = -0.3997 A Vtrans = -0.033281 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000299 A 15:28:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000093438 Vs 15:28:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000087765 Vs 15:28:44 Magnet Current for Main, Imag = 0.0134 A Vtrans = 0.000029 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010528 A 15:28:44 Magnet Current for Trim, Imag = -0.3997 A Vtrans = -0.033281 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000299 A 15:29:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000095241 Vs 15:29:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000088762 Vs 15:29:19 Magnet Current for Main, Imag = 0.0135 A Vtrans = 0.000030 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010528 A 15:29:20 Magnet Current for Trim, Imag = -0.3997 A Vtrans = -0.033280 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000299 A 15:29:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000095662 Vs 15:29:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000089961 Vs 15:29:54 Magnet Current for Main, Imag = 0.0135 A Vtrans = 0.000029 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010528 A 15:29:55 Magnet Current for Trim, Imag = -0.3997 A Vtrans = -0.033279 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000299 A 15:30:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000094918 Vs 15:30:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000088603 Vs 15:30:29 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000091794 +- 0.000000791 Vs 15:30:29 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000091794 +- 0.000000791 Vs BL = -0.00091794 +- 0.00000791 Tm 15:30:37 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00092 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.00092 0.00001 -0.00092 0.00000 15:30:37 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00092 0.00001 SL = -0.0009179 +- 0.0000079 Tm^2/m^n 15:30:37 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0009179 +- 0.0000079 Tm^2/m^n 15:30:37 Magnet system Main current ramping to 0.0000 A... 15:31:07 Magnet system Trim current ramping to -0.5000 A... 15:31:38 Magnetic Field Measurement Measuring the magnet strength... 15:31:38 Integrated Voltage Measurement... 15:31:38 Magnet Current for Main, Imag = 0.0134 A Vtrans = 0.000029 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010528 A 15:31:39 Magnet Current for Trim, Imag = -0.4990 A Vtrans = -0.041562 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000299 A 15:31:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000248740 Vs 15:32:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000242461 Vs 15:32:15 Magnet Current for Main, Imag = 0.0135 A Vtrans = 0.000029 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010528 A 15:32:15 Magnet Current for Trim, Imag = -0.4990 A Vtrans = -0.041561 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000299 A 15:32:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000251507 Vs 15:32:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000243274 Vs 15:32:50 Magnet Current for Main, Imag = 0.0135 A Vtrans = 0.000029 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010528 A 15:32:51 Magnet Current for Trim, Imag = -0.4990 A Vtrans = -0.041561 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000299 A 15:33:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000251489 Vs 15:33:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000244760 Vs 15:33:26 Magnet Current for Main, Imag = 0.0134 A Vtrans = 0.000029 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010528 A 15:33:26 Magnet Current for Trim, Imag = -0.4990 A Vtrans = -0.041562 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000299 A 15:33:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000252254 Vs 15:34:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000245227 Vs 15:34:00 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000247464 +- 0.000001177 Vs 15:34:00 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000247464 +- 0.000001177 Vs BL = -0.00247464 +- 0.00001177 Tm 15:34:08 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00247 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.00247 0.00001 -0.00247 0.00000 15:34:08 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00247 0.00001 SL = -0.0024746 +- 0.0000118 Tm^2/m^n 15:34:08 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0024746 +- 0.0000118 Tm^2/m^n 15:34:08 Magnet system Main current ramping to 0.0000 A... 15:34:39 Magnet system Trim current ramping to -0.6000 A... 15:35:09 Magnetic Field Measurement Measuring the magnet strength... 15:35:09 Integrated Voltage Measurement... 15:35:10 Magnet Current for Main, Imag = 0.0135 A Vtrans = 0.000029 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010528 A 15:35:10 Magnet Current for Trim, Imag = -0.6012 A Vtrans = -0.050075 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000299 A 15:35:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000408261 Vs 15:35:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000404107 Vs 15:35:46 Magnet Current for Main, Imag = 0.0134 A Vtrans = 0.000029 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010528 A 15:35:46 Magnet Current for Trim, Imag = -0.6012 A Vtrans = -0.050075 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000299 A 15:36:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000409932 Vs 15:36:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000405833 Vs 15:36:21 Magnet Current for Main, Imag = 0.0134 A Vtrans = 0.000029 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010528 A 15:36:22 Magnet Current for Trim, Imag = -0.6012 A Vtrans = -0.050075 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000299 A 15:36:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000410280 Vs 15:36:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000405775 Vs 15:36:57 Magnet Current for Main, Imag = 0.0134 A Vtrans = 0.000029 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010528 A 15:36:57 Magnet Current for Trim, Imag = -0.6012 A Vtrans = -0.050076 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000299 A 15:37:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000411176 Vs 15:37:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000405780 Vs 15:37:31 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000407643 +- 0.000000870 Vs 15:37:31 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000407643 +- 0.000000870 Vs BL = -0.00407643 +- 0.00000870 Tm 15:37:39 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00408 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.00408 0.00001 -0.00408 0.00000 15:37:39 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00408 0.00001 SL = -0.0040764 +- 0.0000087 Tm^2/m^n 15:37:39 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0040764 +- 0.0000087 Tm^2/m^n 15:37:39 Magnet system Main current ramping to 0.0000 A... 15:38:10 Magnet system Trim current ramping to 0.0000 A... 15:38:41 Magnetic Field Measurement Measuring the magnet strength... 15:38:41 Integrated Voltage Measurement... 15:38:42 Magnet Current for Main, Imag = 0.0136 A Vtrans = 0.000030 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010528 A 15:38:42 Magnet Current for Trim, Imag = -0.0005 A Vtrans = -0.000015 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000299 A 15:39:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000563586 Vs 15:39:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000533179 Vs 15:39:18 Magnet Current for Main, Imag = 0.0137 A Vtrans = 0.000032 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010528 A 15:39:18 Magnet Current for Trim, Imag = -0.0005 A Vtrans = -0.000014 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000299 A 15:39:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000534772 Vs 15:39:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000536186 Vs 15:39:53 Magnet Current for Main, Imag = 0.0137 A Vtrans = 0.000032 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010528 A 15:39:54 Magnet Current for Trim, Imag = -0.0005 A Vtrans = -0.000015 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000299 A 15:40:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000531189 Vs 15:40:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000537169 Vs 15:40:29 Magnet Current for Main, Imag = 0.0136 A Vtrans = 0.000031 V, Factor V/A = 0.010000 V/A, Zero Current = -0.010528 A 15:40:29 Magnet Current for Trim, Imag = -0.0005 A Vtrans = -0.000015 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000299 A 15:40:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000500878 Vs 15:41:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000583107 Vs 15:41:04 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000540008 +- 0.000005669 Vs 15:41:04 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000540008 +- 0.000005669 Vs BL = 0.00540008 +- 0.00005669 Tm 15:41:11 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00540 0.00006 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00540 0.00006 0.00540 0.00000 15:41:11 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00540 0.00006 SL = 0.0054001 +- 0.0000567 Tm^2/m^n 15:41:11 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0054001 +- 0.0000567 Tm^2/m^n 15:41:23 Name = None, is zeroed 15:41:23 Magnet system Main current ramping to 0.0000 A... 15:41:23 Magnet system Trim current ramping to 0.0000 A...