SLAC Magnetic Measurements Date: 01-17-2012 Time: 16:31:22 Project: FACET_Sector_10 Magnet Type: Dipole Magnet Name: B101EP Serial Number: 1.071.4T Run Number: 9 Measurement Device: 10_wire Operator: sda Comment: Integrated strength. Main ps off after stdz and ramping to 859 A. Trim scan from 0 to -0.4 A. Test Currents for Main (A): 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Test Currents for Trim (A): 0.00 -0.30 -0.32 -0.34 -0.36 -0.38 -0.40 Integrated Field Strength Distance the wire was to be moved = 0.010000 m Number of turns in the wire = 10 Number of measurements for averaging = 4 Main +/- sigma Trim +/- sigma BL sigBL BL/I sigBL/I (A) (A) (A) (A) (Tm) (Tm) (Tm/A) (Tm/A) ----------+---------- ----------+---------- ------------+------------ -------------+------------- -0.0001 0.0000 -0.0004 0.0000 0.0041734 2.95218e-06 0 0 -0.0002 0.0001 -0.3006 0.0000 -0.000515113 1.52154e-05 0 0 -0.0002 0.0000 -0.3006 0.0000 -0.000536586 3.10885e-06 0 0 -0.0002 0.0000 -0.3006 0.0000 -0.000538523 2.23049e-06 0 0 -0.0001 0.0001 -0.3607 0.0000 -0.00134036 5.53061e-05 0 0 -0.0002 0.0001 -0.3607 0.0000 -0.0014262 5.94782e-05 0 0 -0.0002 0.0001 -0.3607 0.0000 -0.00156125 0.000138504 0 0