SLAC Magnetic Measurements Date: 03-07-2019 Time: 10:49:29 Project: FACET_II Magnet Type: Dipole Magnet Name: BCX14720 Serial Number: 2 Run Number: 1 Measurement Device: 10wire Operator: sda Comment: Integrated Field vs current 0-200-0 A in 20 A steps. Warmup for 1 hr at 200 A. BL vs X at 200 A. Standardization for MAIN: 10 cycles from 0.0 A to 200.0 A to 0.0 A Test Currents for MAIN (A): 0.00 20.00 40.00 60.00 80.00 100.00 120.00 140.00 160.00 180.00 200.00 180.00 160.00 140.00 120.00 100.00 80.00 60.00 40.00 20.00 0.00 200.00 10:50:03 Position moved: 0.000000 m 10:50:07 Magnet Current for MAIN, Imag = -0.0048 A Vtrans = -0.000048 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:50:07 Magnet Current for MAIN, Imag = -0.0048 A Vtrans = -0.000048 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:50:08 Magnet Current for MAIN, Imag = -0.0048 A Vtrans = -0.000048 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:50:09 Magnet Current for MAIN, Imag = -0.0047 A Vtrans = -0.000047 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:50:09 Magnet Avgerage Current Measurement for MAIN : Imag = -0.0048 +- 0.0000 A 10:50:31 Initial Zero Current Measurement for MAIN, Imag_zero = -0.00478887 A 10:50:31 Ambient Measurement Device(s) Being Used, type = None 10:50:31 Magnet Voltage Measurement Device(s) Being Used, type = HP34970 10:50:32 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 10:50:32 XMAG Device(s) Being Used, type = None 10:50:32 Ambient Measurement Device(s) Being Used, type = HP34970 10:50:32 Magnet system MAIN current ramping to 200.0000 A... 10:51:29 Magnet Current for MAIN, Imag = 200.1219 A Vtrans = 2.001171 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 10:51:30 MAIN (V) Voltage Measurement, V = -30.539159 V 10:51:31 Temperature Measurement, Probe Number = 0, T = 25.626000 C 10:51:31 Temperature Measurement, Probe Number = 1, T = 29.578000 C 10:51:32 Temperature Measurement, Probe Number = 2, T = 17.435000 C 10:51:33 Sensor Voltage Measurement, Sensor Number = 0, V = 2.305718 V 10:51:33 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.305718 (V, A, ohm, ...), Measured Value = 28.134974 (C, atm, Hz, ...) 10:51:33 Sensor Voltage Measurement, Sensor Number = 1, V = 2.536446 V 10:51:33 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.536446 (V, A, ohm, ...), Measured Value = 31.339535 (C, atm, Hz, ...) 10:51:34 Sensor Voltage Measurement, Sensor Number = 2, V = 2.647541 V 10:51:34 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.647541 (V, A, ohm, ...), Measured Value = 123.565575 (C, atm, Hz, ...) 10:51:35 Sensor Voltage Measurement, Sensor Number = 3, V = 1.102267 V 10:51:35 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.102267 (V, A, ohm, ...), Measured Value = 7.670055 (C, atm, Hz, ...) 10:51:35 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.54 P2 = Magnet Core, Value = 25.63 P3 = Coil, Value = 29.58 P4 = Ambient Temp (C), Value = 17.43 P5 = Supply Temp(C), Value = 28.13 P6 = Return Temp(C), Value = 31.34 P7 = Supply Pres(psi), Value = 123.57 P8 = Return Pres(psi), Value = 7.67 10:52:36 Magnet Current for MAIN, Imag = 200.1224 A Vtrans = 2.001176 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 10:52:36 MAIN (V) Voltage Measurement, V = -30.701968 V 10:52:37 Temperature Measurement, Probe Number = 0, T = 25.638000 C 10:52:38 Temperature Measurement, Probe Number = 1, T = 29.352000 C 10:52:38 Temperature Measurement, Probe Number = 2, T = 17.382000 C 10:52:39 Sensor Voltage Measurement, Sensor Number = 0, V = 2.304273 V 10:52:39 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.304273 (V, A, ohm, ...), Measured Value = 28.114901 (C, atm, Hz, ...) 10:52:40 Sensor Voltage Measurement, Sensor Number = 1, V = 2.529648 V 10:52:40 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.529648 (V, A, ohm, ...), Measured Value = 31.245106 (C, atm, Hz, ...) 10:52:40 Sensor Voltage Measurement, Sensor Number = 2, V = 2.659812 V 10:52:40 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.659812 (V, A, ohm, ...), Measured Value = 124.485900 (C, atm, Hz, ...) 10:52:41 Sensor Voltage Measurement, Sensor Number = 3, V = 1.102324 V 10:52:41 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.102324 (V, A, ohm, ...), Measured Value = 7.674337 (C, atm, Hz, ...) 10:52:41 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.70 P2 = Magnet Core, Value = 25.64 P3 = Coil, Value = 29.35 P4 = Ambient Temp (C), Value = 17.38 P5 = Supply Temp(C), Value = 28.11 P6 = Return Temp(C), Value = 31.25 P7 = Supply Pres(psi), Value = 124.49 P8 = Return Pres(psi), Value = 7.67 10:53:42 Magnet Current for MAIN, Imag = 200.1230 A Vtrans = 2.001182 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 10:53:42 MAIN (V) Voltage Measurement, V = -30.806615 V 10:53:43 Temperature Measurement, Probe Number = 0, T = 25.637000 C 10:53:44 Temperature Measurement, Probe Number = 1, T = 29.598000 C 10:53:44 Temperature Measurement, Probe Number = 2, T = 17.422000 C 10:53:45 Sensor Voltage Measurement, Sensor Number = 0, V = 2.303777 V 10:53:45 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.303777 (V, A, ohm, ...), Measured Value = 28.108017 (C, atm, Hz, ...) 10:53:46 Sensor Voltage Measurement, Sensor Number = 1, V = 2.525393 V 10:53:46 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.525393 (V, A, ohm, ...), Measured Value = 31.186018 (C, atm, Hz, ...) 10:53:46 Sensor Voltage Measurement, Sensor Number = 2, V = 2.658716 V 10:53:46 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.658716 (V, A, ohm, ...), Measured Value = 124.403723 (C, atm, Hz, ...) 10:53:47 Sensor Voltage Measurement, Sensor Number = 3, V = 1.102084 V 10:53:47 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.102084 (V, A, ohm, ...), Measured Value = 7.656323 (C, atm, Hz, ...) 10:53:47 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.81 P2 = Magnet Core, Value = 25.64 P3 = Coil, Value = 29.60 P4 = Ambient Temp (C), Value = 17.42 P5 = Supply Temp(C), Value = 28.11 P6 = Return Temp(C), Value = 31.19 P7 = Supply Pres(psi), Value = 124.40 P8 = Return Pres(psi), Value = 7.66 10:54:48 Magnet Current for MAIN, Imag = 200.1233 A Vtrans = 2.001185 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 10:54:49 MAIN (V) Voltage Measurement, V = -30.865198 V 10:54:49 Temperature Measurement, Probe Number = 0, T = 25.644000 C 10:54:50 Temperature Measurement, Probe Number = 1, T = 29.964000 C 10:54:51 Temperature Measurement, Probe Number = 2, T = 17.393000 C 10:54:51 Sensor Voltage Measurement, Sensor Number = 0, V = 2.302723 V 10:54:51 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.302723 (V, A, ohm, ...), Measured Value = 28.093382 (C, atm, Hz, ...) 10:54:52 Sensor Voltage Measurement, Sensor Number = 1, V = 2.527688 V 10:54:52 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.527688 (V, A, ohm, ...), Measured Value = 31.217883 (C, atm, Hz, ...) 10:54:53 Sensor Voltage Measurement, Sensor Number = 2, V = 2.660967 V 10:54:53 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.660967 (V, A, ohm, ...), Measured Value = 124.572555 (C, atm, Hz, ...) 10:54:53 Sensor Voltage Measurement, Sensor Number = 3, V = 1.102488 V 10:54:53 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.102488 (V, A, ohm, ...), Measured Value = 7.686637 (C, atm, Hz, ...) 10:54:53 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.87 P2 = Magnet Core, Value = 25.64 P3 = Coil, Value = 29.96 P4 = Ambient Temp (C), Value = 17.39 P5 = Supply Temp(C), Value = 28.09 P6 = Return Temp(C), Value = 31.22 P7 = Supply Pres(psi), Value = 124.57 P8 = Return Pres(psi), Value = 7.69 10:55:54 Magnet Current for MAIN, Imag = 200.1237 A Vtrans = 2.001189 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 10:55:55 MAIN (V) Voltage Measurement, V = -30.896639 V 10:55:55 Temperature Measurement, Probe Number = 0, T = 25.646000 C 10:55:56 Temperature Measurement, Probe Number = 1, T = 30.367000 C 10:55:57 Temperature Measurement, Probe Number = 2, T = 17.397000 C 10:55:57 Sensor Voltage Measurement, Sensor Number = 0, V = 2.302782 V 10:55:57 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.302782 (V, A, ohm, ...), Measured Value = 28.094194 (C, atm, Hz, ...) 10:55:58 Sensor Voltage Measurement, Sensor Number = 1, V = 2.535507 V 10:55:58 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.535507 (V, A, ohm, ...), Measured Value = 31.326489 (C, atm, Hz, ...) 10:55:59 Sensor Voltage Measurement, Sensor Number = 2, V = 2.657654 V 10:55:59 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.657654 (V, A, ohm, ...), Measured Value = 124.324027 (C, atm, Hz, ...) 10:55:59 Sensor Voltage Measurement, Sensor Number = 3, V = 1.102211 V 10:55:59 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.102211 (V, A, ohm, ...), Measured Value = 7.665855 (C, atm, Hz, ...) 10:55:59 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.90 P2 = Magnet Core, Value = 25.65 P3 = Coil, Value = 30.37 P4 = Ambient Temp (C), Value = 17.40 P5 = Supply Temp(C), Value = 28.09 P6 = Return Temp(C), Value = 31.33 P7 = Supply Pres(psi), Value = 124.32 P8 = Return Pres(psi), Value = 7.67 10:57:00 Magnet Current for MAIN, Imag = 200.1230 A Vtrans = 2.001182 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 10:57:01 MAIN (V) Voltage Measurement, V = -30.912564 V 10:57:01 Temperature Measurement, Probe Number = 0, T = 25.654000 C 10:57:02 Temperature Measurement, Probe Number = 1, T = 30.643000 C 10:57:03 Temperature Measurement, Probe Number = 2, T = 17.393000 C 10:57:03 Sensor Voltage Measurement, Sensor Number = 0, V = 2.302421 V 10:57:04 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.302421 (V, A, ohm, ...), Measured Value = 28.089181 (C, atm, Hz, ...) 10:57:04 Sensor Voltage Measurement, Sensor Number = 1, V = 2.548044 V 10:57:04 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.548044 (V, A, ohm, ...), Measured Value = 31.500608 (C, atm, Hz, ...) 10:57:05 Sensor Voltage Measurement, Sensor Number = 2, V = 2.655606 V 10:57:05 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.655606 (V, A, ohm, ...), Measured Value = 124.170450 (C, atm, Hz, ...) 10:57:06 Sensor Voltage Measurement, Sensor Number = 3, V = 1.102442 V 10:57:06 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.102442 (V, A, ohm, ...), Measured Value = 7.683113 (C, atm, Hz, ...) 10:57:06 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.91 P2 = Magnet Core, Value = 25.65 P3 = Coil, Value = 30.64 P4 = Ambient Temp (C), Value = 17.39 P5 = Supply Temp(C), Value = 28.09 P6 = Return Temp(C), Value = 31.50 P7 = Supply Pres(psi), Value = 124.17 P8 = Return Pres(psi), Value = 7.68 10:58:06 Magnet Current for MAIN, Imag = 200.1232 A Vtrans = 2.001184 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 10:58:07 MAIN (V) Voltage Measurement, V = -30.920412 V 10:58:08 Temperature Measurement, Probe Number = 0, T = 25.667000 C 10:58:08 Temperature Measurement, Probe Number = 1, T = 30.824000 C 10:58:09 Temperature Measurement, Probe Number = 2, T = 17.357000 C 10:58:10 Sensor Voltage Measurement, Sensor Number = 0, V = 2.302316 V 10:58:10 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.302316 (V, A, ohm, ...), Measured Value = 28.087715 (C, atm, Hz, ...) 10:58:10 Sensor Voltage Measurement, Sensor Number = 1, V = 2.563430 V 10:58:10 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.563430 (V, A, ohm, ...), Measured Value = 31.714308 (C, atm, Hz, ...) 10:58:11 Sensor Voltage Measurement, Sensor Number = 2, V = 2.657999 V 10:58:11 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.657999 (V, A, ohm, ...), Measured Value = 124.349955 (C, atm, Hz, ...) 10:58:12 Sensor Voltage Measurement, Sensor Number = 3, V = 1.102324 V 10:58:12 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.102324 (V, A, ohm, ...), Measured Value = 7.674337 (C, atm, Hz, ...) 10:58:12 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.92 P2 = Magnet Core, Value = 25.67 P3 = Coil, Value = 30.82 P4 = Ambient Temp (C), Value = 17.36 P5 = Supply Temp(C), Value = 28.09 P6 = Return Temp(C), Value = 31.71 P7 = Supply Pres(psi), Value = 124.35 P8 = Return Pres(psi), Value = 7.67 10:59:13 Magnet Current for MAIN, Imag = 200.1237 A Vtrans = 2.001189 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 10:59:13 MAIN (V) Voltage Measurement, V = -30.923500 V 10:59:14 Temperature Measurement, Probe Number = 0, T = 25.684000 C 10:59:15 Temperature Measurement, Probe Number = 1, T = 31.041000 C 10:59:15 Temperature Measurement, Probe Number = 2, T = 16.994000 C 10:59:16 Sensor Voltage Measurement, Sensor Number = 0, V = 2.301397 V 10:59:16 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.301397 (V, A, ohm, ...), Measured Value = 28.074951 (C, atm, Hz, ...) 10:59:17 Sensor Voltage Measurement, Sensor Number = 1, V = 2.579633 V 10:59:17 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.579633 (V, A, ohm, ...), Measured Value = 31.939340 (C, atm, Hz, ...) 10:59:17 Sensor Voltage Measurement, Sensor Number = 2, V = 2.668650 V 10:59:17 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.668650 (V, A, ohm, ...), Measured Value = 125.148728 (C, atm, Hz, ...) 10:59:18 Sensor Voltage Measurement, Sensor Number = 3, V = 1.102312 V 10:59:18 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.102312 (V, A, ohm, ...), Measured Value = 7.673385 (C, atm, Hz, ...) 10:59:18 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.92 P2 = Magnet Core, Value = 25.68 P3 = Coil, Value = 31.04 P4 = Ambient Temp (C), Value = 16.99 P5 = Supply Temp(C), Value = 28.07 P6 = Return Temp(C), Value = 31.94 P7 = Supply Pres(psi), Value = 125.15 P8 = Return Pres(psi), Value = 7.67 11:00:19 Magnet Current for MAIN, Imag = 200.1232 A Vtrans = 2.001184 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:00:19 MAIN (V) Voltage Measurement, V = -30.924534 V 11:00:20 Temperature Measurement, Probe Number = 0, T = 25.691000 C 11:00:21 Temperature Measurement, Probe Number = 1, T = 31.233000 C 11:00:21 Temperature Measurement, Probe Number = 2, T = 17.079000 C 11:00:22 Sensor Voltage Measurement, Sensor Number = 0, V = 2.301613 V 11:00:22 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.301613 (V, A, ohm, ...), Measured Value = 28.077953 (C, atm, Hz, ...) 11:00:23 Sensor Voltage Measurement, Sensor Number = 1, V = 2.595122 V 11:00:23 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.595122 (V, A, ohm, ...), Measured Value = 32.154469 (C, atm, Hz, ...) 11:00:23 Sensor Voltage Measurement, Sensor Number = 2, V = 2.659830 V 11:00:23 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.659830 (V, A, ohm, ...), Measured Value = 124.487228 (C, atm, Hz, ...) 11:00:24 Sensor Voltage Measurement, Sensor Number = 3, V = 1.102487 V 11:00:24 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.102487 (V, A, ohm, ...), Measured Value = 7.686540 (C, atm, Hz, ...) 11:00:24 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.92 P2 = Magnet Core, Value = 25.69 P3 = Coil, Value = 31.23 P4 = Ambient Temp (C), Value = 17.08 P5 = Supply Temp(C), Value = 28.08 P6 = Return Temp(C), Value = 32.15 P7 = Supply Pres(psi), Value = 124.49 P8 = Return Pres(psi), Value = 7.69 11:01:25 Magnet Current for MAIN, Imag = 200.1234 A Vtrans = 2.001186 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:01:26 MAIN (V) Voltage Measurement, V = -30.925095 V 11:01:26 Temperature Measurement, Probe Number = 0, T = 25.692000 C 11:01:27 Temperature Measurement, Probe Number = 1, T = 31.207000 C 11:01:28 Temperature Measurement, Probe Number = 2, T = 17.128000 C 11:01:28 Sensor Voltage Measurement, Sensor Number = 0, V = 2.301297 V 11:01:28 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.301297 (V, A, ohm, ...), Measured Value = 28.073574 (C, atm, Hz, ...) 11:01:29 Sensor Voltage Measurement, Sensor Number = 1, V = 2.609481 V 11:01:29 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.609481 (V, A, ohm, ...), Measured Value = 32.353906 (C, atm, Hz, ...) 11:01:30 Sensor Voltage Measurement, Sensor Number = 2, V = 2.653804 V 11:01:30 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.653804 (V, A, ohm, ...), Measured Value = 124.035270 (C, atm, Hz, ...) 11:01:30 Sensor Voltage Measurement, Sensor Number = 3, V = 1.102890 V 11:01:30 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.102890 (V, A, ohm, ...), Measured Value = 7.716765 (C, atm, Hz, ...) 11:01:30 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 25.69 P3 = Coil, Value = 31.21 P4 = Ambient Temp (C), Value = 17.13 P5 = Supply Temp(C), Value = 28.07 P6 = Return Temp(C), Value = 32.35 P7 = Supply Pres(psi), Value = 124.04 P8 = Return Pres(psi), Value = 7.72 11:02:31 Magnet Current for MAIN, Imag = 200.1228 A Vtrans = 2.001180 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:02:32 MAIN (V) Voltage Measurement, V = -30.925516 V 11:02:32 Temperature Measurement, Probe Number = 0, T = 25.711000 C 11:02:33 Temperature Measurement, Probe Number = 1, T = 31.169000 C 11:02:34 Temperature Measurement, Probe Number = 2, T = 17.206000 C 11:02:34 Sensor Voltage Measurement, Sensor Number = 0, V = 2.301290 V 11:02:34 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.301290 (V, A, ohm, ...), Measured Value = 28.073468 (C, atm, Hz, ...) 11:02:35 Sensor Voltage Measurement, Sensor Number = 1, V = 2.622449 V 11:02:35 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.622449 (V, A, ohm, ...), Measured Value = 32.534010 (C, atm, Hz, ...) 11:02:36 Sensor Voltage Measurement, Sensor Number = 2, V = 2.660451 V 11:02:36 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.660451 (V, A, ohm, ...), Measured Value = 124.533848 (C, atm, Hz, ...) 11:02:36 Sensor Voltage Measurement, Sensor Number = 3, V = 1.102867 V 11:02:36 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.102867 (V, A, ohm, ...), Measured Value = 7.715047 (C, atm, Hz, ...) 11:02:36 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 25.71 P3 = Coil, Value = 31.17 P4 = Ambient Temp (C), Value = 17.21 P5 = Supply Temp(C), Value = 28.07 P6 = Return Temp(C), Value = 32.53 P7 = Supply Pres(psi), Value = 124.53 P8 = Return Pres(psi), Value = 7.72 11:03:37 Magnet Current for MAIN, Imag = 200.1233 A Vtrans = 2.001185 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:03:38 MAIN (V) Voltage Measurement, V = -30.926039 V 11:03:39 Temperature Measurement, Probe Number = 0, T = 25.727000 C 11:03:39 Temperature Measurement, Probe Number = 1, T = 31.193000 C 11:03:40 Temperature Measurement, Probe Number = 2, T = 17.222000 C 11:03:40 Sensor Voltage Measurement, Sensor Number = 0, V = 2.301723 V 11:03:40 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.301723 (V, A, ohm, ...), Measured Value = 28.079489 (C, atm, Hz, ...) 11:03:41 Sensor Voltage Measurement, Sensor Number = 1, V = 2.634460 V 11:03:41 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.634460 (V, A, ohm, ...), Measured Value = 32.700839 (C, atm, Hz, ...) 11:03:42 Sensor Voltage Measurement, Sensor Number = 2, V = 2.658387 V 11:03:42 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.658387 (V, A, ohm, ...), Measured Value = 124.379033 (C, atm, Hz, ...) 11:03:42 Sensor Voltage Measurement, Sensor Number = 3, V = 1.102688 V 11:03:43 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.102688 (V, A, ohm, ...), Measured Value = 7.701607 (C, atm, Hz, ...) 11:03:43 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 25.73 P3 = Coil, Value = 31.19 P4 = Ambient Temp (C), Value = 17.22 P5 = Supply Temp(C), Value = 28.08 P6 = Return Temp(C), Value = 32.70 P7 = Supply Pres(psi), Value = 124.38 P8 = Return Pres(psi), Value = 7.70 11:04:43 Magnet Current for MAIN, Imag = 200.1234 A Vtrans = 2.001186 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:04:44 MAIN (V) Voltage Measurement, V = -30.926754 V 11:04:45 Temperature Measurement, Probe Number = 0, T = 25.745000 C 11:04:45 Temperature Measurement, Probe Number = 1, T = 31.251000 C 11:04:46 Temperature Measurement, Probe Number = 2, T = 17.242000 C 11:04:47 Sensor Voltage Measurement, Sensor Number = 0, V = 2.302351 V 11:04:47 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.302351 (V, A, ohm, ...), Measured Value = 28.088210 (C, atm, Hz, ...) 11:04:47 Sensor Voltage Measurement, Sensor Number = 1, V = 2.645511 V 11:04:47 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.645511 (V, A, ohm, ...), Measured Value = 32.854321 (C, atm, Hz, ...) 11:04:48 Sensor Voltage Measurement, Sensor Number = 2, V = 2.653083 V 11:04:48 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.653083 (V, A, ohm, ...), Measured Value = 123.981217 (C, atm, Hz, ...) 11:04:49 Sensor Voltage Measurement, Sensor Number = 3, V = 1.102889 V 11:04:49 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.102889 (V, A, ohm, ...), Measured Value = 7.716667 (C, atm, Hz, ...) 11:04:49 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 25.75 P3 = Coil, Value = 31.25 P4 = Ambient Temp (C), Value = 17.24 P5 = Supply Temp(C), Value = 28.09 P6 = Return Temp(C), Value = 32.85 P7 = Supply Pres(psi), Value = 123.98 P8 = Return Pres(psi), Value = 7.72 11:05:50 Magnet Current for MAIN, Imag = 200.1230 A Vtrans = 2.001182 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:05:50 MAIN (V) Voltage Measurement, V = -30.927519 V 11:05:51 Temperature Measurement, Probe Number = 0, T = 25.768000 C 11:05:51 Temperature Measurement, Probe Number = 1, T = 31.262000 C 11:05:52 Temperature Measurement, Probe Number = 2, T = 17.257000 C 11:05:53 Sensor Voltage Measurement, Sensor Number = 0, V = 2.302552 V 11:05:53 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.302552 (V, A, ohm, ...), Measured Value = 28.090999 (C, atm, Hz, ...) 11:05:53 Sensor Voltage Measurement, Sensor Number = 1, V = 2.655245 V 11:05:54 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.655245 (V, A, ohm, ...), Measured Value = 32.989514 (C, atm, Hz, ...) 11:05:54 Sensor Voltage Measurement, Sensor Number = 2, V = 2.663061 V 11:05:54 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.663061 (V, A, ohm, ...), Measured Value = 124.729560 (C, atm, Hz, ...) 11:05:55 Sensor Voltage Measurement, Sensor Number = 3, V = 1.102558 V 11:05:55 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.102558 (V, A, ohm, ...), Measured Value = 7.691880 (C, atm, Hz, ...) 11:05:55 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 25.77 P3 = Coil, Value = 31.26 P4 = Ambient Temp (C), Value = 17.26 P5 = Supply Temp(C), Value = 28.09 P6 = Return Temp(C), Value = 32.99 P7 = Supply Pres(psi), Value = 124.73 P8 = Return Pres(psi), Value = 7.69 11:06:56 Magnet Current for MAIN, Imag = 200.1232 A Vtrans = 2.001184 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:06:56 MAIN (V) Voltage Measurement, V = -30.928170 V 11:06:57 Temperature Measurement, Probe Number = 0, T = 25.772000 C 11:06:58 Temperature Measurement, Probe Number = 1, T = 31.341000 C 11:06:58 Temperature Measurement, Probe Number = 2, T = 17.299000 C 11:06:59 Sensor Voltage Measurement, Sensor Number = 0, V = 2.302704 V 11:06:59 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.302704 (V, A, ohm, ...), Measured Value = 28.093117 (C, atm, Hz, ...) 11:07:00 Sensor Voltage Measurement, Sensor Number = 1, V = 2.663935 V 11:07:00 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.663935 (V, A, ohm, ...), Measured Value = 33.110212 (C, atm, Hz, ...) 11:07:00 Sensor Voltage Measurement, Sensor Number = 2, V = 2.658480 V 11:07:00 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.658480 (V, A, ohm, ...), Measured Value = 124.385993 (C, atm, Hz, ...) 11:07:01 Sensor Voltage Measurement, Sensor Number = 3, V = 1.102725 V 11:07:01 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.102725 (V, A, ohm, ...), Measured Value = 7.704367 (C, atm, Hz, ...) 11:07:01 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 25.77 P3 = Coil, Value = 31.34 P4 = Ambient Temp (C), Value = 17.30 P5 = Supply Temp(C), Value = 28.09 P6 = Return Temp(C), Value = 33.11 P7 = Supply Pres(psi), Value = 124.39 P8 = Return Pres(psi), Value = 7.70 11:08:02 Magnet Current for MAIN, Imag = 200.1228 A Vtrans = 2.001180 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:08:02 MAIN (V) Voltage Measurement, V = -30.928642 V 11:08:03 Temperature Measurement, Probe Number = 0, T = 25.789000 C 11:08:04 Temperature Measurement, Probe Number = 1, T = 31.352000 C 11:08:04 Temperature Measurement, Probe Number = 2, T = 17.326000 C 11:08:05 Sensor Voltage Measurement, Sensor Number = 0, V = 2.303018 V 11:08:05 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.303018 (V, A, ohm, ...), Measured Value = 28.097478 (C, atm, Hz, ...) 11:08:06 Sensor Voltage Measurement, Sensor Number = 1, V = 2.671733 V 11:08:06 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.671733 (V, A, ohm, ...), Measured Value = 33.218519 (C, atm, Hz, ...) 11:08:06 Sensor Voltage Measurement, Sensor Number = 2, V = 2.657065 V 11:08:06 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.657065 (V, A, ohm, ...), Measured Value = 124.279890 (C, atm, Hz, ...) 11:08:07 Sensor Voltage Measurement, Sensor Number = 3, V = 1.102851 V 11:08:07 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.102851 (V, A, ohm, ...), Measured Value = 7.713810 (C, atm, Hz, ...) 11:08:07 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 25.79 P3 = Coil, Value = 31.35 P4 = Ambient Temp (C), Value = 17.33 P5 = Supply Temp(C), Value = 28.10 P6 = Return Temp(C), Value = 33.22 P7 = Supply Pres(psi), Value = 124.28 P8 = Return Pres(psi), Value = 7.71 11:09:08 Magnet Current for MAIN, Imag = 200.1230 A Vtrans = 2.001182 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:09:09 MAIN (V) Voltage Measurement, V = -30.929127 V 11:09:09 Temperature Measurement, Probe Number = 0, T = 25.805000 C 11:09:10 Temperature Measurement, Probe Number = 1, T = 31.331000 C 11:09:11 Temperature Measurement, Probe Number = 2, T = 17.258000 C 11:09:11 Sensor Voltage Measurement, Sensor Number = 0, V = 2.303224 V 11:09:11 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.303224 (V, A, ohm, ...), Measured Value = 28.100337 (C, atm, Hz, ...) 11:09:12 Sensor Voltage Measurement, Sensor Number = 1, V = 2.678973 V 11:09:12 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.678973 (V, A, ohm, ...), Measured Value = 33.319075 (C, atm, Hz, ...) 11:09:13 Sensor Voltage Measurement, Sensor Number = 2, V = 2.648246 V 11:09:13 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.648246 (V, A, ohm, ...), Measured Value = 123.618488 (C, atm, Hz, ...) 11:09:13 Sensor Voltage Measurement, Sensor Number = 3, V = 1.102930 V 11:09:13 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.102930 (V, A, ohm, ...), Measured Value = 7.719720 (C, atm, Hz, ...) 11:09:13 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 25.80 P3 = Coil, Value = 31.33 P4 = Ambient Temp (C), Value = 17.26 P5 = Supply Temp(C), Value = 28.10 P6 = Return Temp(C), Value = 33.32 P7 = Supply Pres(psi), Value = 123.62 P8 = Return Pres(psi), Value = 7.72 11:10:14 Magnet Current for MAIN, Imag = 200.1234 A Vtrans = 2.001186 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:10:15 MAIN (V) Voltage Measurement, V = -30.929650 V 11:10:15 Temperature Measurement, Probe Number = 0, T = 25.822000 C 11:10:16 Temperature Measurement, Probe Number = 1, T = 31.295000 C 11:10:17 Temperature Measurement, Probe Number = 2, T = 17.225000 C 11:10:17 Sensor Voltage Measurement, Sensor Number = 0, V = 2.303289 V 11:10:17 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.303289 (V, A, ohm, ...), Measured Value = 28.101237 (C, atm, Hz, ...) 11:10:18 Sensor Voltage Measurement, Sensor Number = 1, V = 2.685252 V 11:10:18 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.685252 (V, A, ohm, ...), Measured Value = 33.406285 (C, atm, Hz, ...) 11:10:19 Sensor Voltage Measurement, Sensor Number = 2, V = 2.657472 V 11:10:19 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.657472 (V, A, ohm, ...), Measured Value = 124.310393 (C, atm, Hz, ...) 11:10:19 Sensor Voltage Measurement, Sensor Number = 3, V = 1.103139 V 11:10:19 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.103139 (V, A, ohm, ...), Measured Value = 7.735448 (C, atm, Hz, ...) 11:10:19 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 25.82 P3 = Coil, Value = 31.30 P4 = Ambient Temp (C), Value = 17.23 P5 = Supply Temp(C), Value = 28.10 P6 = Return Temp(C), Value = 33.41 P7 = Supply Pres(psi), Value = 124.31 P8 = Return Pres(psi), Value = 7.74 11:11:20 Magnet Current for MAIN, Imag = 200.1230 A Vtrans = 2.001182 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:11:21 MAIN (V) Voltage Measurement, V = -30.929906 V 11:11:21 Temperature Measurement, Probe Number = 0, T = 25.831000 C 11:11:22 Temperature Measurement, Probe Number = 1, T = 31.318000 C 11:11:23 Temperature Measurement, Probe Number = 2, T = 17.227000 C 11:11:23 Sensor Voltage Measurement, Sensor Number = 0, V = 2.303076 V 11:11:23 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.303076 (V, A, ohm, ...), Measured Value = 28.098272 (C, atm, Hz, ...) 11:11:24 Sensor Voltage Measurement, Sensor Number = 1, V = 2.690635 V 11:11:24 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.690635 (V, A, ohm, ...), Measured Value = 33.481049 (C, atm, Hz, ...) 11:11:25 Sensor Voltage Measurement, Sensor Number = 2, V = 2.660646 V 11:11:25 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.660646 (V, A, ohm, ...), Measured Value = 124.548435 (C, atm, Hz, ...) 11:11:26 Sensor Voltage Measurement, Sensor Number = 3, V = 1.103180 V 11:11:26 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.103180 (V, A, ohm, ...), Measured Value = 7.738500 (C, atm, Hz, ...) 11:11:26 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 25.83 P3 = Coil, Value = 31.32 P4 = Ambient Temp (C), Value = 17.23 P5 = Supply Temp(C), Value = 28.10 P6 = Return Temp(C), Value = 33.48 P7 = Supply Pres(psi), Value = 124.55 P8 = Return Pres(psi), Value = 7.74 11:12:26 Magnet Current for MAIN, Imag = 200.1235 A Vtrans = 2.001187 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:12:27 MAIN (V) Voltage Measurement, V = -30.930174 V 11:12:28 Temperature Measurement, Probe Number = 0, T = 25.844000 C 11:12:28 Temperature Measurement, Probe Number = 1, T = 31.319000 C 11:12:29 Temperature Measurement, Probe Number = 2, T = 17.262000 C 11:12:30 Sensor Voltage Measurement, Sensor Number = 0, V = 2.303554 V 11:12:30 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.303554 (V, A, ohm, ...), Measured Value = 28.104910 (C, atm, Hz, ...) 11:12:30 Sensor Voltage Measurement, Sensor Number = 1, V = 2.695389 V 11:12:30 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.695389 (V, A, ohm, ...), Measured Value = 33.547074 (C, atm, Hz, ...) 11:12:31 Sensor Voltage Measurement, Sensor Number = 2, V = 2.665876 V 11:12:31 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.665876 (V, A, ohm, ...), Measured Value = 124.940715 (C, atm, Hz, ...) 11:12:32 Sensor Voltage Measurement, Sensor Number = 3, V = 1.103258 V 11:12:32 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.103258 (V, A, ohm, ...), Measured Value = 7.744313 (C, atm, Hz, ...) 11:12:32 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 25.84 P3 = Coil, Value = 31.32 P4 = Ambient Temp (C), Value = 17.26 P5 = Supply Temp(C), Value = 28.10 P6 = Return Temp(C), Value = 33.55 P7 = Supply Pres(psi), Value = 124.94 P8 = Return Pres(psi), Value = 7.74 11:13:32 Magnet Current for MAIN, Imag = 200.1230 A Vtrans = 2.001182 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:13:33 MAIN (V) Voltage Measurement, V = -30.930250 V 11:13:34 Temperature Measurement, Probe Number = 0, T = 25.845000 C 11:13:34 Temperature Measurement, Probe Number = 1, T = 31.262000 C 11:13:35 Temperature Measurement, Probe Number = 2, T = 17.253000 C 11:13:36 Sensor Voltage Measurement, Sensor Number = 0, V = 2.303021 V 11:13:36 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.303021 (V, A, ohm, ...), Measured Value = 28.097513 (C, atm, Hz, ...) 11:13:36 Sensor Voltage Measurement, Sensor Number = 1, V = 2.699454 V 11:13:36 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.699454 (V, A, ohm, ...), Measured Value = 33.603531 (C, atm, Hz, ...) 11:13:37 Sensor Voltage Measurement, Sensor Number = 2, V = 2.661535 V 11:13:37 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.661535 (V, A, ohm, ...), Measured Value = 124.615162 (C, atm, Hz, ...) 11:13:38 Sensor Voltage Measurement, Sensor Number = 3, V = 1.103022 V 11:13:38 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.103022 (V, A, ohm, ...), Measured Value = 7.726680 (C, atm, Hz, ...) 11:13:38 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 25.84 P3 = Coil, Value = 31.26 P4 = Ambient Temp (C), Value = 17.25 P5 = Supply Temp(C), Value = 28.10 P6 = Return Temp(C), Value = 33.60 P7 = Supply Pres(psi), Value = 124.62 P8 = Return Pres(psi), Value = 7.73 11:14:39 Magnet Current for MAIN, Imag = 200.1233 A Vtrans = 2.001185 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:14:39 MAIN (V) Voltage Measurement, V = -30.930020 V 11:14:40 Temperature Measurement, Probe Number = 0, T = 25.853000 C 11:14:41 Temperature Measurement, Probe Number = 1, T = 31.244000 C 11:14:41 Temperature Measurement, Probe Number = 2, T = 17.230000 C 11:14:42 Sensor Voltage Measurement, Sensor Number = 0, V = 2.302816 V 11:14:42 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.302816 (V, A, ohm, ...), Measured Value = 28.094671 (C, atm, Hz, ...) 11:14:43 Sensor Voltage Measurement, Sensor Number = 1, V = 2.703105 V 11:14:43 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.703105 (V, A, ohm, ...), Measured Value = 33.654232 (C, atm, Hz, ...) 11:14:43 Sensor Voltage Measurement, Sensor Number = 2, V = 2.651025 V 11:14:43 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.651025 (V, A, ohm, ...), Measured Value = 123.826875 (C, atm, Hz, ...) 11:14:44 Sensor Voltage Measurement, Sensor Number = 3, V = 1.103195 V 11:14:44 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.103195 (V, A, ohm, ...), Measured Value = 7.739640 (C, atm, Hz, ...) 11:14:44 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 25.85 P3 = Coil, Value = 31.24 P4 = Ambient Temp (C), Value = 17.23 P5 = Supply Temp(C), Value = 28.09 P6 = Return Temp(C), Value = 33.65 P7 = Supply Pres(psi), Value = 123.83 P8 = Return Pres(psi), Value = 7.74 11:15:45 Magnet Current for MAIN, Imag = 200.1229 A Vtrans = 2.001181 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:15:45 MAIN (V) Voltage Measurement, V = -30.929612 V 11:15:46 Temperature Measurement, Probe Number = 0, T = 25.864000 C 11:15:47 Temperature Measurement, Probe Number = 1, T = 31.213000 C 11:15:47 Temperature Measurement, Probe Number = 2, T = 17.219000 C 11:15:48 Sensor Voltage Measurement, Sensor Number = 0, V = 2.302385 V 11:15:48 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.302385 (V, A, ohm, ...), Measured Value = 28.088686 (C, atm, Hz, ...) 11:15:49 Sensor Voltage Measurement, Sensor Number = 1, V = 2.706315 V 11:15:49 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.706315 (V, A, ohm, ...), Measured Value = 33.698825 (C, atm, Hz, ...) 11:15:49 Sensor Voltage Measurement, Sensor Number = 2, V = 2.659881 V 11:15:49 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.659881 (V, A, ohm, ...), Measured Value = 124.491045 (C, atm, Hz, ...) 11:15:50 Sensor Voltage Measurement, Sensor Number = 3, V = 1.103252 V 11:15:50 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.103252 (V, A, ohm, ...), Measured Value = 7.743930 (C, atm, Hz, ...) 11:15:50 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 25.86 P3 = Coil, Value = 31.21 P4 = Ambient Temp (C), Value = 17.22 P5 = Supply Temp(C), Value = 28.09 P6 = Return Temp(C), Value = 33.70 P7 = Supply Pres(psi), Value = 124.49 P8 = Return Pres(psi), Value = 7.74 11:16:51 Magnet Current for MAIN, Imag = 200.1232 A Vtrans = 2.001184 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:16:52 MAIN (V) Voltage Measurement, V = -30.929574 V 11:16:52 Temperature Measurement, Probe Number = 0, T = 25.880000 C 11:16:53 Temperature Measurement, Probe Number = 1, T = 31.147000 C 11:16:54 Temperature Measurement, Probe Number = 2, T = 17.244000 C 11:16:54 Sensor Voltage Measurement, Sensor Number = 0, V = 2.302567 V 11:16:54 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.302567 (V, A, ohm, ...), Measured Value = 28.091210 (C, atm, Hz, ...) 11:16:55 Sensor Voltage Measurement, Sensor Number = 1, V = 2.709168 V 11:16:55 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.709168 (V, A, ohm, ...), Measured Value = 33.738440 (C, atm, Hz, ...) 11:16:56 Sensor Voltage Measurement, Sensor Number = 2, V = 2.658372 V 11:16:56 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.658372 (V, A, ohm, ...), Measured Value = 124.377885 (C, atm, Hz, ...) 11:16:56 Sensor Voltage Measurement, Sensor Number = 3, V = 1.103157 V 11:16:56 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.103157 (V, A, ohm, ...), Measured Value = 7.736783 (C, atm, Hz, ...) 11:16:56 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 25.88 P3 = Coil, Value = 31.15 P4 = Ambient Temp (C), Value = 17.24 P5 = Supply Temp(C), Value = 28.09 P6 = Return Temp(C), Value = 33.74 P7 = Supply Pres(psi), Value = 124.38 P8 = Return Pres(psi), Value = 7.74 11:17:57 Magnet Current for MAIN, Imag = 200.1225 A Vtrans = 2.001177 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:17:58 MAIN (V) Voltage Measurement, V = -30.929344 V 11:17:58 Temperature Measurement, Probe Number = 0, T = 25.883000 C 11:17:59 Temperature Measurement, Probe Number = 1, T = 31.134000 C 11:18:00 Temperature Measurement, Probe Number = 2, T = 17.262000 C 11:18:00 Sensor Voltage Measurement, Sensor Number = 0, V = 2.302082 V 11:18:00 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.302082 (V, A, ohm, ...), Measured Value = 28.084467 (C, atm, Hz, ...) 11:18:01 Sensor Voltage Measurement, Sensor Number = 1, V = 2.711832 V 11:18:01 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.711832 (V, A, ohm, ...), Measured Value = 33.775443 (C, atm, Hz, ...) 11:18:02 Sensor Voltage Measurement, Sensor Number = 2, V = 2.658664 V 11:18:02 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.658664 (V, A, ohm, ...), Measured Value = 124.399815 (C, atm, Hz, ...) 11:18:02 Sensor Voltage Measurement, Sensor Number = 3, V = 1.103080 V 11:18:02 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.103080 (V, A, ohm, ...), Measured Value = 7.730970 (C, atm, Hz, ...) 11:18:02 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 25.88 P3 = Coil, Value = 31.13 P4 = Ambient Temp (C), Value = 17.26 P5 = Supply Temp(C), Value = 28.08 P6 = Return Temp(C), Value = 33.78 P7 = Supply Pres(psi), Value = 124.40 P8 = Return Pres(psi), Value = 7.73 11:19:03 Magnet Current for MAIN, Imag = 200.1228 A Vtrans = 2.001180 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:19:04 MAIN (V) Voltage Measurement, V = -30.929114 V 11:19:05 Temperature Measurement, Probe Number = 0, T = 25.888000 C 11:19:05 Temperature Measurement, Probe Number = 1, T = 31.178000 C 11:19:06 Temperature Measurement, Probe Number = 2, T = 17.266000 C 11:19:06 Sensor Voltage Measurement, Sensor Number = 0, V = 2.302244 V 11:19:06 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.302244 (V, A, ohm, ...), Measured Value = 28.086726 (C, atm, Hz, ...) 11:19:07 Sensor Voltage Measurement, Sensor Number = 1, V = 2.714194 V 11:19:07 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.714194 (V, A, ohm, ...), Measured Value = 33.808244 (C, atm, Hz, ...) 11:19:08 Sensor Voltage Measurement, Sensor Number = 2, V = 2.653858 V 11:19:08 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.653858 (V, A, ohm, ...), Measured Value = 124.039365 (C, atm, Hz, ...) 11:19:08 Sensor Voltage Measurement, Sensor Number = 3, V = 1.103341 V 11:19:09 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.103341 (V, A, ohm, ...), Measured Value = 7.750605 (C, atm, Hz, ...) 11:19:09 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 25.89 P3 = Coil, Value = 31.18 P4 = Ambient Temp (C), Value = 17.27 P5 = Supply Temp(C), Value = 28.09 P6 = Return Temp(C), Value = 33.81 P7 = Supply Pres(psi), Value = 124.04 P8 = Return Pres(psi), Value = 7.75 11:20:09 Magnet Current for MAIN, Imag = 200.1229 A Vtrans = 2.001181 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:20:10 MAIN (V) Voltage Measurement, V = -30.929076 V 11:20:11 Temperature Measurement, Probe Number = 0, T = 25.902000 C 11:20:11 Temperature Measurement, Probe Number = 1, T = 31.168000 C 11:20:12 Temperature Measurement, Probe Number = 2, T = 17.310000 C 11:20:13 Sensor Voltage Measurement, Sensor Number = 0, V = 2.302160 V 11:20:13 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.302160 (V, A, ohm, ...), Measured Value = 28.085561 (C, atm, Hz, ...) 11:20:13 Sensor Voltage Measurement, Sensor Number = 1, V = 2.716258 V 11:20:13 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.716258 (V, A, ohm, ...), Measured Value = 33.836914 (C, atm, Hz, ...) 11:20:14 Sensor Voltage Measurement, Sensor Number = 2, V = 2.656161 V 11:20:14 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.656161 (V, A, ohm, ...), Measured Value = 124.212105 (C, atm, Hz, ...) 11:20:15 Sensor Voltage Measurement, Sensor Number = 3, V = 1.103214 V 11:20:15 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.103214 (V, A, ohm, ...), Measured Value = 7.741073 (C, atm, Hz, ...) 11:20:15 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 25.90 P3 = Coil, Value = 31.17 P4 = Ambient Temp (C), Value = 17.31 P5 = Supply Temp(C), Value = 28.09 P6 = Return Temp(C), Value = 33.84 P7 = Supply Pres(psi), Value = 124.21 P8 = Return Pres(psi), Value = 7.74 11:21:15 Magnet Current for MAIN, Imag = 200.1229 A Vtrans = 2.001181 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:21:16 MAIN (V) Voltage Measurement, V = -30.929114 V 11:21:17 Temperature Measurement, Probe Number = 0, T = 25.914000 C 11:21:17 Temperature Measurement, Probe Number = 1, T = 31.187000 C 11:21:18 Temperature Measurement, Probe Number = 2, T = 17.325000 C 11:21:19 Sensor Voltage Measurement, Sensor Number = 0, V = 2.302348 V 11:21:19 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.302348 (V, A, ohm, ...), Measured Value = 28.088174 (C, atm, Hz, ...) 11:21:19 Sensor Voltage Measurement, Sensor Number = 1, V = 2.718386 V 11:21:19 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.718386 (V, A, ohm, ...), Measured Value = 33.866467 (C, atm, Hz, ...) 11:21:20 Sensor Voltage Measurement, Sensor Number = 2, V = 2.662050 V 11:21:20 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.662050 (V, A, ohm, ...), Measured Value = 124.653773 (C, atm, Hz, ...) 11:21:21 Sensor Voltage Measurement, Sensor Number = 3, V = 1.103275 V 11:21:21 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.103275 (V, A, ohm, ...), Measured Value = 7.745647 (C, atm, Hz, ...) 11:21:21 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 25.91 P3 = Coil, Value = 31.19 P4 = Ambient Temp (C), Value = 17.32 P5 = Supply Temp(C), Value = 28.09 P6 = Return Temp(C), Value = 33.87 P7 = Supply Pres(psi), Value = 124.65 P8 = Return Pres(psi), Value = 7.75 11:22:22 Magnet Current for MAIN, Imag = 200.1228 A Vtrans = 2.001180 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:22:22 MAIN (V) Voltage Measurement, V = -30.929063 V 11:22:23 Temperature Measurement, Probe Number = 0, T = 25.909000 C 11:22:24 Temperature Measurement, Probe Number = 1, T = 31.160000 C 11:22:24 Temperature Measurement, Probe Number = 2, T = 17.304000 C 11:22:25 Sensor Voltage Measurement, Sensor Number = 0, V = 2.301867 V 11:22:25 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.301867 (V, A, ohm, ...), Measured Value = 28.081483 (C, atm, Hz, ...) 11:22:26 Sensor Voltage Measurement, Sensor Number = 1, V = 2.720049 V 11:22:26 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.720049 (V, A, ohm, ...), Measured Value = 33.889575 (C, atm, Hz, ...) 11:22:26 Sensor Voltage Measurement, Sensor Number = 2, V = 2.658930 V 11:22:26 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.658930 (V, A, ohm, ...), Measured Value = 124.419735 (C, atm, Hz, ...) 11:22:27 Sensor Voltage Measurement, Sensor Number = 3, V = 1.103155 V 11:22:27 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.103155 (V, A, ohm, ...), Measured Value = 7.736595 (C, atm, Hz, ...) 11:22:27 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 25.91 P3 = Coil, Value = 31.16 P4 = Ambient Temp (C), Value = 17.30 P5 = Supply Temp(C), Value = 28.08 P6 = Return Temp(C), Value = 33.89 P7 = Supply Pres(psi), Value = 124.42 P8 = Return Pres(psi), Value = 7.74 11:23:28 Magnet Current for MAIN, Imag = 200.1225 A Vtrans = 2.001177 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:23:28 MAIN (V) Voltage Measurement, V = -30.928872 V 11:23:29 Temperature Measurement, Probe Number = 0, T = 25.918000 C 11:23:30 Temperature Measurement, Probe Number = 1, T = 31.171000 C 11:23:30 Temperature Measurement, Probe Number = 2, T = 17.300000 C 11:23:31 Sensor Voltage Measurement, Sensor Number = 0, V = 2.301490 V 11:23:31 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.301490 (V, A, ohm, ...), Measured Value = 28.076257 (C, atm, Hz, ...) 11:23:32 Sensor Voltage Measurement, Sensor Number = 1, V = 2.721216 V 11:23:32 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.721216 (V, A, ohm, ...), Measured Value = 33.905781 (C, atm, Hz, ...) 11:23:32 Sensor Voltage Measurement, Sensor Number = 2, V = 2.652850 V 11:23:32 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.652850 (V, A, ohm, ...), Measured Value = 123.963772 (C, atm, Hz, ...) 11:23:33 Sensor Voltage Measurement, Sensor Number = 3, V = 1.103261 V 11:23:33 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.103261 (V, A, ohm, ...), Measured Value = 7.744598 (C, atm, Hz, ...) 11:23:33 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 25.92 P3 = Coil, Value = 31.17 P4 = Ambient Temp (C), Value = 17.30 P5 = Supply Temp(C), Value = 28.08 P6 = Return Temp(C), Value = 33.91 P7 = Supply Pres(psi), Value = 123.96 P8 = Return Pres(psi), Value = 7.74 11:24:34 Magnet Current for MAIN, Imag = 200.1228 A Vtrans = 2.001180 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:24:34 MAIN (V) Voltage Measurement, V = -30.928719 V 11:24:35 Temperature Measurement, Probe Number = 0, T = 25.924000 C 11:24:36 Temperature Measurement, Probe Number = 1, T = 31.182000 C 11:24:36 Temperature Measurement, Probe Number = 2, T = 17.290000 C 11:24:37 Sensor Voltage Measurement, Sensor Number = 0, V = 2.301742 V 11:24:37 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.301742 (V, A, ohm, ...), Measured Value = 28.079753 (C, atm, Hz, ...) 11:24:38 Sensor Voltage Measurement, Sensor Number = 1, V = 2.722461 V 11:24:38 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.722461 (V, A, ohm, ...), Measured Value = 33.923064 (C, atm, Hz, ...) 11:24:38 Sensor Voltage Measurement, Sensor Number = 2, V = 2.661206 V 11:24:38 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.661206 (V, A, ohm, ...), Measured Value = 124.590472 (C, atm, Hz, ...) 11:24:39 Sensor Voltage Measurement, Sensor Number = 3, V = 1.103340 V 11:24:39 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.103340 (V, A, ohm, ...), Measured Value = 7.750508 (C, atm, Hz, ...) 11:24:39 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 25.92 P3 = Coil, Value = 31.18 P4 = Ambient Temp (C), Value = 17.29 P5 = Supply Temp(C), Value = 28.08 P6 = Return Temp(C), Value = 33.92 P7 = Supply Pres(psi), Value = 124.59 P8 = Return Pres(psi), Value = 7.75 11:25:40 Magnet Current for MAIN, Imag = 200.1226 A Vtrans = 2.001179 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:25:41 MAIN (V) Voltage Measurement, V = -30.928630 V 11:25:41 Temperature Measurement, Probe Number = 0, T = 25.939000 C 11:25:42 Temperature Measurement, Probe Number = 1, T = 31.203000 C 11:25:43 Temperature Measurement, Probe Number = 2, T = 17.281000 C 11:25:43 Sensor Voltage Measurement, Sensor Number = 0, V = 2.301830 V 11:25:43 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.301830 (V, A, ohm, ...), Measured Value = 28.080971 (C, atm, Hz, ...) 11:25:44 Sensor Voltage Measurement, Sensor Number = 1, V = 2.723484 V 11:25:44 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.723484 (V, A, ohm, ...), Measured Value = 33.937275 (C, atm, Hz, ...) 11:25:45 Sensor Voltage Measurement, Sensor Number = 2, V = 2.653981 V 11:25:45 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.653981 (V, A, ohm, ...), Measured Value = 124.048613 (C, atm, Hz, ...) 11:25:45 Sensor Voltage Measurement, Sensor Number = 3, V = 1.103447 V 11:25:45 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.103447 (V, A, ohm, ...), Measured Value = 7.758518 (C, atm, Hz, ...) 11:25:45 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 25.94 P3 = Coil, Value = 31.20 P4 = Ambient Temp (C), Value = 17.28 P5 = Supply Temp(C), Value = 28.08 P6 = Return Temp(C), Value = 33.94 P7 = Supply Pres(psi), Value = 124.05 P8 = Return Pres(psi), Value = 7.76 11:26:46 Magnet Current for MAIN, Imag = 200.1226 A Vtrans = 2.001179 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:26:47 MAIN (V) Voltage Measurement, V = -30.928681 V 11:26:47 Temperature Measurement, Probe Number = 0, T = 25.947000 C 11:26:48 Temperature Measurement, Probe Number = 1, T = 31.219000 C 11:26:49 Temperature Measurement, Probe Number = 2, T = 17.256000 C 11:26:49 Sensor Voltage Measurement, Sensor Number = 0, V = 2.301746 V 11:26:49 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.301746 (V, A, ohm, ...), Measured Value = 28.079806 (C, atm, Hz, ...) 11:26:50 Sensor Voltage Measurement, Sensor Number = 1, V = 2.724316 V 11:26:50 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.724316 (V, A, ohm, ...), Measured Value = 33.948839 (C, atm, Hz, ...) 11:26:51 Sensor Voltage Measurement, Sensor Number = 2, V = 2.667024 V 11:26:51 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.667024 (V, A, ohm, ...), Measured Value = 125.026800 (C, atm, Hz, ...) 11:26:51 Sensor Voltage Measurement, Sensor Number = 3, V = 1.103428 V 11:26:51 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.103428 (V, A, ohm, ...), Measured Value = 7.757085 (C, atm, Hz, ...) 11:26:51 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 25.95 P3 = Coil, Value = 31.22 P4 = Ambient Temp (C), Value = 17.26 P5 = Supply Temp(C), Value = 28.08 P6 = Return Temp(C), Value = 33.95 P7 = Supply Pres(psi), Value = 125.03 P8 = Return Pres(psi), Value = 7.76 11:27:52 Magnet Current for MAIN, Imag = 200.1225 A Vtrans = 2.001177 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:27:53 MAIN (V) Voltage Measurement, V = -30.928668 V 11:27:53 Temperature Measurement, Probe Number = 0, T = 25.960000 C 11:27:54 Temperature Measurement, Probe Number = 1, T = 31.163000 C 11:27:55 Temperature Measurement, Probe Number = 2, T = 17.272000 C 11:27:55 Sensor Voltage Measurement, Sensor Number = 0, V = 2.301402 V 11:27:55 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.301402 (V, A, ohm, ...), Measured Value = 28.075022 (C, atm, Hz, ...) 11:27:56 Sensor Voltage Measurement, Sensor Number = 1, V = 2.725016 V 11:27:56 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.725016 (V, A, ohm, ...), Measured Value = 33.958549 (C, atm, Hz, ...) 11:27:57 Sensor Voltage Measurement, Sensor Number = 2, V = 2.654564 V 11:27:57 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.654564 (V, A, ohm, ...), Measured Value = 124.092278 (C, atm, Hz, ...) 11:27:57 Sensor Voltage Measurement, Sensor Number = 3, V = 1.103244 V 11:27:57 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.103244 (V, A, ohm, ...), Measured Value = 7.743263 (C, atm, Hz, ...) 11:27:57 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 25.96 P3 = Coil, Value = 31.16 P4 = Ambient Temp (C), Value = 17.27 P5 = Supply Temp(C), Value = 28.08 P6 = Return Temp(C), Value = 33.96 P7 = Supply Pres(psi), Value = 124.09 P8 = Return Pres(psi), Value = 7.74 11:28:58 Magnet Current for MAIN, Imag = 200.1228 A Vtrans = 2.001180 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:28:59 MAIN (V) Voltage Measurement, V = -30.928311 V 11:28:59 Temperature Measurement, Probe Number = 0, T = 25.967000 C 11:29:00 Temperature Measurement, Probe Number = 1, T = 31.142000 C 11:29:01 Temperature Measurement, Probe Number = 2, T = 17.306000 C 11:29:01 Sensor Voltage Measurement, Sensor Number = 0, V = 2.301342 V 11:29:01 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.301342 (V, A, ohm, ...), Measured Value = 28.074192 (C, atm, Hz, ...) 11:29:02 Sensor Voltage Measurement, Sensor Number = 1, V = 2.725650 V 11:29:02 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.725650 (V, A, ohm, ...), Measured Value = 33.967357 (C, atm, Hz, ...) 11:29:03 Sensor Voltage Measurement, Sensor Number = 2, V = 2.654091 V 11:29:03 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.654091 (V, A, ohm, ...), Measured Value = 124.056817 (C, atm, Hz, ...) 11:29:03 Sensor Voltage Measurement, Sensor Number = 3, V = 1.103237 V 11:29:04 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.103237 (V, A, ohm, ...), Measured Value = 7.742790 (C, atm, Hz, ...) 11:29:04 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 25.97 P3 = Coil, Value = 31.14 P4 = Ambient Temp (C), Value = 17.31 P5 = Supply Temp(C), Value = 28.07 P6 = Return Temp(C), Value = 33.97 P7 = Supply Pres(psi), Value = 124.06 P8 = Return Pres(psi), Value = 7.74 11:30:04 Magnet Current for MAIN, Imag = 200.1226 A Vtrans = 2.001179 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:30:05 MAIN (V) Voltage Measurement, V = -30.928094 V 11:30:06 Temperature Measurement, Probe Number = 0, T = 25.976000 C 11:30:06 Temperature Measurement, Probe Number = 1, T = 31.138000 C 11:30:07 Temperature Measurement, Probe Number = 2, T = 17.330000 C 11:30:08 Sensor Voltage Measurement, Sensor Number = 0, V = 2.300982 V 11:30:08 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.300982 (V, A, ohm, ...), Measured Value = 28.069196 (C, atm, Hz, ...) 11:30:08 Sensor Voltage Measurement, Sensor Number = 1, V = 2.726306 V 11:30:08 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.726306 (V, A, ohm, ...), Measured Value = 33.976472 (C, atm, Hz, ...) 11:30:09 Sensor Voltage Measurement, Sensor Number = 2, V = 2.652076 V 11:30:09 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.652076 (V, A, ohm, ...), Measured Value = 123.905715 (C, atm, Hz, ...) 11:30:10 Sensor Voltage Measurement, Sensor Number = 3, V = 1.103418 V 11:30:10 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.103418 (V, A, ohm, ...), Measured Value = 7.756328 (C, atm, Hz, ...) 11:30:10 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 25.98 P3 = Coil, Value = 31.14 P4 = Ambient Temp (C), Value = 17.33 P5 = Supply Temp(C), Value = 28.07 P6 = Return Temp(C), Value = 33.98 P7 = Supply Pres(psi), Value = 123.91 P8 = Return Pres(psi), Value = 7.76 11:31:11 Magnet Current for MAIN, Imag = 200.1233 A Vtrans = 2.001185 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:31:12 MAIN (V) Voltage Measurement, V = -30.927481 V 11:31:12 Temperature Measurement, Probe Number = 0, T = 25.978000 C 11:31:13 Temperature Measurement, Probe Number = 1, T = 31.141000 C 11:31:14 Temperature Measurement, Probe Number = 2, T = 17.261000 C 11:31:14 Sensor Voltage Measurement, Sensor Number = 0, V = 2.300138 V 11:31:14 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.300138 (V, A, ohm, ...), Measured Value = 28.057474 (C, atm, Hz, ...) 11:31:15 Sensor Voltage Measurement, Sensor Number = 1, V = 2.727229 V 11:31:15 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.727229 (V, A, ohm, ...), Measured Value = 33.989289 (C, atm, Hz, ...) 11:31:16 Sensor Voltage Measurement, Sensor Number = 2, V = 2.666964 V 11:31:16 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.666964 (V, A, ohm, ...), Measured Value = 125.022323 (C, atm, Hz, ...) 11:31:16 Sensor Voltage Measurement, Sensor Number = 3, V = 1.103155 V 11:31:16 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.103155 (V, A, ohm, ...), Measured Value = 7.736595 (C, atm, Hz, ...) 11:31:16 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 25.98 P3 = Coil, Value = 31.14 P4 = Ambient Temp (C), Value = 17.26 P5 = Supply Temp(C), Value = 28.06 P6 = Return Temp(C), Value = 33.99 P7 = Supply Pres(psi), Value = 125.02 P8 = Return Pres(psi), Value = 7.74 11:32:17 Magnet Current for MAIN, Imag = 200.1230 A Vtrans = 2.001182 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:32:18 MAIN (V) Voltage Measurement, V = -30.926805 V 11:32:18 Temperature Measurement, Probe Number = 0, T = 25.982000 C 11:32:19 Temperature Measurement, Probe Number = 1, T = 31.179000 C 11:32:20 Temperature Measurement, Probe Number = 2, T = 17.264000 C 11:32:20 Sensor Voltage Measurement, Sensor Number = 0, V = 2.299963 V 11:32:20 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.299963 (V, A, ohm, ...), Measured Value = 28.055037 (C, atm, Hz, ...) 11:32:21 Sensor Voltage Measurement, Sensor Number = 1, V = 2.727934 V 11:32:21 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.727934 (V, A, ohm, ...), Measured Value = 33.999087 (C, atm, Hz, ...) 11:32:22 Sensor Voltage Measurement, Sensor Number = 2, V = 2.655711 V 11:32:22 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.655711 (V, A, ohm, ...), Measured Value = 124.178362 (C, atm, Hz, ...) 11:32:22 Sensor Voltage Measurement, Sensor Number = 3, V = 1.103504 V 11:32:22 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.103504 (V, A, ohm, ...), Measured Value = 7.762808 (C, atm, Hz, ...) 11:32:22 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 25.98 P3 = Coil, Value = 31.18 P4 = Ambient Temp (C), Value = 17.26 P5 = Supply Temp(C), Value = 28.06 P6 = Return Temp(C), Value = 34.00 P7 = Supply Pres(psi), Value = 124.18 P8 = Return Pres(psi), Value = 7.76 11:33:23 Magnet Current for MAIN, Imag = 200.1228 A Vtrans = 2.001180 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:33:24 MAIN (V) Voltage Measurement, V = -30.926320 V 11:33:25 Temperature Measurement, Probe Number = 0, T = 25.990000 C 11:33:25 Temperature Measurement, Probe Number = 1, T = 31.220000 C 11:33:26 Temperature Measurement, Probe Number = 2, T = 17.311000 C 11:33:27 Sensor Voltage Measurement, Sensor Number = 0, V = 2.299935 V 11:33:27 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.299935 (V, A, ohm, ...), Measured Value = 28.054650 (C, atm, Hz, ...) 11:33:27 Sensor Voltage Measurement, Sensor Number = 1, V = 2.728637 V 11:33:27 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.728637 (V, A, ohm, ...), Measured Value = 34.008850 (C, atm, Hz, ...) 11:33:28 Sensor Voltage Measurement, Sensor Number = 2, V = 2.664531 V 11:33:28 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.664531 (V, A, ohm, ...), Measured Value = 124.839855 (C, atm, Hz, ...) 11:33:29 Sensor Voltage Measurement, Sensor Number = 3, V = 1.103526 V 11:33:29 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.103526 (V, A, ohm, ...), Measured Value = 7.764428 (C, atm, Hz, ...) 11:33:29 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 25.99 P3 = Coil, Value = 31.22 P4 = Ambient Temp (C), Value = 17.31 P5 = Supply Temp(C), Value = 28.05 P6 = Return Temp(C), Value = 34.01 P7 = Supply Pres(psi), Value = 124.84 P8 = Return Pres(psi), Value = 7.76 11:34:29 Magnet Current for MAIN, Imag = 200.1226 A Vtrans = 2.001179 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:34:30 MAIN (V) Voltage Measurement, V = -30.926486 V 11:34:31 Temperature Measurement, Probe Number = 0, T = 26.001000 C 11:34:31 Temperature Measurement, Probe Number = 1, T = 31.245000 C 11:34:32 Temperature Measurement, Probe Number = 2, T = 17.234000 C 11:34:33 Sensor Voltage Measurement, Sensor Number = 0, V = 2.300545 V 11:34:33 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.300545 (V, A, ohm, ...), Measured Value = 28.063124 (C, atm, Hz, ...) 11:34:33 Sensor Voltage Measurement, Sensor Number = 1, V = 2.729170 V 11:34:33 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.729170 (V, A, ohm, ...), Measured Value = 34.016247 (C, atm, Hz, ...) 11:34:34 Sensor Voltage Measurement, Sensor Number = 2, V = 2.660541 V 11:34:34 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.660541 (V, A, ohm, ...), Measured Value = 124.540612 (C, atm, Hz, ...) 11:34:35 Sensor Voltage Measurement, Sensor Number = 3, V = 1.103269 V 11:34:35 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.103269 (V, A, ohm, ...), Measured Value = 7.745175 (C, atm, Hz, ...) 11:34:35 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 26.00 P3 = Coil, Value = 31.25 P4 = Ambient Temp (C), Value = 17.23 P5 = Supply Temp(C), Value = 28.06 P6 = Return Temp(C), Value = 34.02 P7 = Supply Pres(psi), Value = 124.54 P8 = Return Pres(psi), Value = 7.75 11:35:35 Magnet Current for MAIN, Imag = 200.1228 A Vtrans = 2.001180 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:35:36 MAIN (V) Voltage Measurement, V = -30.926805 V 11:35:37 Temperature Measurement, Probe Number = 0, T = 26.005000 C 11:35:37 Temperature Measurement, Probe Number = 1, T = 31.260000 C 11:35:38 Temperature Measurement, Probe Number = 2, T = 17.259000 C 11:35:39 Sensor Voltage Measurement, Sensor Number = 0, V = 2.301003 V 11:35:39 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.301003 (V, A, ohm, ...), Measured Value = 28.069479 (C, atm, Hz, ...) 11:35:39 Sensor Voltage Measurement, Sensor Number = 1, V = 2.729415 V 11:35:39 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.729415 (V, A, ohm, ...), Measured Value = 34.019654 (C, atm, Hz, ...) 11:35:40 Sensor Voltage Measurement, Sensor Number = 2, V = 2.657668 V 11:35:40 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.657668 (V, A, ohm, ...), Measured Value = 124.325078 (C, atm, Hz, ...) 11:35:41 Sensor Voltage Measurement, Sensor Number = 3, V = 1.103683 V 11:35:41 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.103683 (V, A, ohm, ...), Measured Value = 7.776247 (C, atm, Hz, ...) 11:35:41 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 26.00 P3 = Coil, Value = 31.26 P4 = Ambient Temp (C), Value = 17.26 P5 = Supply Temp(C), Value = 28.07 P6 = Return Temp(C), Value = 34.02 P7 = Supply Pres(psi), Value = 124.33 P8 = Return Pres(psi), Value = 7.78 11:36:42 Magnet Current for MAIN, Imag = 200.1224 A Vtrans = 2.001176 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:36:42 MAIN (V) Voltage Measurement, V = -30.927609 V 11:36:43 Temperature Measurement, Probe Number = 0, T = 26.000000 C 11:36:44 Temperature Measurement, Probe Number = 1, T = 31.260000 C 11:36:44 Temperature Measurement, Probe Number = 2, T = 17.226000 C 11:36:45 Sensor Voltage Measurement, Sensor Number = 0, V = 2.302467 V 11:36:45 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.302467 (V, A, ohm, ...), Measured Value = 28.089815 (C, atm, Hz, ...) 11:36:46 Sensor Voltage Measurement, Sensor Number = 1, V = 2.729240 V 11:36:46 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.729240 (V, A, ohm, ...), Measured Value = 34.017218 (C, atm, Hz, ...) 11:36:46 Sensor Voltage Measurement, Sensor Number = 2, V = 2.657637 V 11:36:46 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.657637 (V, A, ohm, ...), Measured Value = 124.322783 (C, atm, Hz, ...) 11:36:47 Sensor Voltage Measurement, Sensor Number = 3, V = 1.103472 V 11:36:47 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.103472 (V, A, ohm, ...), Measured Value = 7.760422 (C, atm, Hz, ...) 11:36:47 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 26.00 P3 = Coil, Value = 31.26 P4 = Ambient Temp (C), Value = 17.23 P5 = Supply Temp(C), Value = 28.09 P6 = Return Temp(C), Value = 34.02 P7 = Supply Pres(psi), Value = 124.32 P8 = Return Pres(psi), Value = 7.76 11:37:48 Magnet Current for MAIN, Imag = 200.1226 A Vtrans = 2.001179 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:37:48 MAIN (V) Voltage Measurement, V = -30.928374 V 11:37:49 Temperature Measurement, Probe Number = 0, T = 26.009000 C 11:37:50 Temperature Measurement, Probe Number = 1, T = 31.356000 C 11:37:50 Temperature Measurement, Probe Number = 2, T = 17.212000 C 11:37:51 Sensor Voltage Measurement, Sensor Number = 0, V = 2.302174 V 11:37:51 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.302174 (V, A, ohm, ...), Measured Value = 28.085756 (C, atm, Hz, ...) 11:37:52 Sensor Voltage Measurement, Sensor Number = 1, V = 2.729193 V 11:37:52 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.729193 (V, A, ohm, ...), Measured Value = 34.016564 (C, atm, Hz, ...) 11:37:52 Sensor Voltage Measurement, Sensor Number = 2, V = 2.664378 V 11:37:52 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.664378 (V, A, ohm, ...), Measured Value = 124.828320 (C, atm, Hz, ...) 11:37:53 Sensor Voltage Measurement, Sensor Number = 3, V = 1.103452 V 11:37:53 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.103452 (V, A, ohm, ...), Measured Value = 7.758900 (C, atm, Hz, ...) 11:37:53 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 26.01 P3 = Coil, Value = 31.36 P4 = Ambient Temp (C), Value = 17.21 P5 = Supply Temp(C), Value = 28.09 P6 = Return Temp(C), Value = 34.02 P7 = Supply Pres(psi), Value = 124.83 P8 = Return Pres(psi), Value = 7.76 11:38:54 Magnet Current for MAIN, Imag = 200.1218 A Vtrans = 2.001170 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:38:55 MAIN (V) Voltage Measurement, V = -30.928808 V 11:38:55 Temperature Measurement, Probe Number = 0, T = 26.019000 C 11:38:56 Temperature Measurement, Probe Number = 1, T = 31.317000 C 11:38:56 Temperature Measurement, Probe Number = 2, T = 17.205000 C 11:38:57 Sensor Voltage Measurement, Sensor Number = 0, V = 2.302246 V 11:38:57 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.302246 (V, A, ohm, ...), Measured Value = 28.086744 (C, atm, Hz, ...) 11:38:58 Sensor Voltage Measurement, Sensor Number = 1, V = 2.729125 V 11:38:58 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.729125 (V, A, ohm, ...), Measured Value = 34.015629 (C, atm, Hz, ...) 11:38:58 Sensor Voltage Measurement, Sensor Number = 2, V = 2.660510 V 11:38:59 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.660510 (V, A, ohm, ...), Measured Value = 124.538235 (C, atm, Hz, ...) 11:38:59 Sensor Voltage Measurement, Sensor Number = 3, V = 1.103357 V 11:38:59 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.103357 (V, A, ohm, ...), Measured Value = 7.751752 (C, atm, Hz, ...) 11:38:59 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 26.02 P3 = Coil, Value = 31.32 P4 = Ambient Temp (C), Value = 17.20 P5 = Supply Temp(C), Value = 28.09 P6 = Return Temp(C), Value = 34.02 P7 = Supply Pres(psi), Value = 124.54 P8 = Return Pres(psi), Value = 7.75 11:40:00 Magnet Current for MAIN, Imag = 200.1232 A Vtrans = 2.001184 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:40:01 MAIN (V) Voltage Measurement, V = -30.929357 V 11:40:01 Temperature Measurement, Probe Number = 0, T = 26.030000 C 11:40:02 Temperature Measurement, Probe Number = 1, T = 31.261000 C 11:40:03 Temperature Measurement, Probe Number = 2, T = 17.247000 C 11:40:03 Sensor Voltage Measurement, Sensor Number = 0, V = 2.303221 V 11:40:03 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.303221 (V, A, ohm, ...), Measured Value = 28.100285 (C, atm, Hz, ...) 11:40:04 Sensor Voltage Measurement, Sensor Number = 1, V = 2.729083 V 11:40:04 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.729083 (V, A, ohm, ...), Measured Value = 34.015046 (C, atm, Hz, ...) 11:40:05 Sensor Voltage Measurement, Sensor Number = 2, V = 2.668337 V 11:40:05 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.668337 (V, A, ohm, ...), Measured Value = 125.125275 (C, atm, Hz, ...) 11:40:05 Sensor Voltage Measurement, Sensor Number = 3, V = 1.103430 V 11:40:05 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.103430 (V, A, ohm, ...), Measured Value = 7.757280 (C, atm, Hz, ...) 11:40:05 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 26.03 P3 = Coil, Value = 31.26 P4 = Ambient Temp (C), Value = 17.25 P5 = Supply Temp(C), Value = 28.10 P6 = Return Temp(C), Value = 34.02 P7 = Supply Pres(psi), Value = 125.13 P8 = Return Pres(psi), Value = 7.76 11:41:06 Magnet Current for MAIN, Imag = 200.1224 A Vtrans = 2.001176 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:41:07 MAIN (V) Voltage Measurement, V = -30.929906 V 11:41:07 Temperature Measurement, Probe Number = 0, T = 26.032000 C 11:41:08 Temperature Measurement, Probe Number = 1, T = 31.307000 C 11:41:09 Temperature Measurement, Probe Number = 2, T = 17.258000 C 11:41:09 Sensor Voltage Measurement, Sensor Number = 0, V = 2.302965 V 11:41:09 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.302965 (V, A, ohm, ...), Measured Value = 28.096736 (C, atm, Hz, ...) 11:41:10 Sensor Voltage Measurement, Sensor Number = 1, V = 2.729039 V 11:41:10 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.729039 (V, A, ohm, ...), Measured Value = 34.014428 (C, atm, Hz, ...) 11:41:11 Sensor Voltage Measurement, Sensor Number = 2, V = 2.655689 V 11:41:11 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.655689 (V, A, ohm, ...), Measured Value = 124.176645 (C, atm, Hz, ...) 11:41:11 Sensor Voltage Measurement, Sensor Number = 3, V = 1.103644 V 11:41:12 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.103644 (V, A, ohm, ...), Measured Value = 7.773293 (C, atm, Hz, ...) 11:41:12 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 26.03 P3 = Coil, Value = 31.31 P4 = Ambient Temp (C), Value = 17.26 P5 = Supply Temp(C), Value = 28.10 P6 = Return Temp(C), Value = 34.01 P7 = Supply Pres(psi), Value = 124.18 P8 = Return Pres(psi), Value = 7.77 11:42:12 Magnet Current for MAIN, Imag = 200.1226 A Vtrans = 2.001179 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:42:13 MAIN (V) Voltage Measurement, V = -30.930531 V 11:42:14 Temperature Measurement, Probe Number = 0, T = 26.027000 C 11:42:14 Temperature Measurement, Probe Number = 1, T = 31.362000 C 11:42:15 Temperature Measurement, Probe Number = 2, T = 17.265000 C 11:42:16 Sensor Voltage Measurement, Sensor Number = 0, V = 2.303440 V 11:42:16 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.303440 (V, A, ohm, ...), Measured Value = 28.103339 (C, atm, Hz, ...) 11:42:16 Sensor Voltage Measurement, Sensor Number = 1, V = 2.729228 V 11:42:16 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.729228 (V, A, ohm, ...), Measured Value = 34.017058 (C, atm, Hz, ...) 11:42:17 Sensor Voltage Measurement, Sensor Number = 2, V = 2.652042 V 11:42:17 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.652042 (V, A, ohm, ...), Measured Value = 123.903143 (C, atm, Hz, ...) 11:42:18 Sensor Voltage Measurement, Sensor Number = 3, V = 1.103587 V 11:42:18 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.103587 (V, A, ohm, ...), Measured Value = 7.769002 (C, atm, Hz, ...) 11:42:18 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 26.03 P3 = Coil, Value = 31.36 P4 = Ambient Temp (C), Value = 17.27 P5 = Supply Temp(C), Value = 28.10 P6 = Return Temp(C), Value = 34.02 P7 = Supply Pres(psi), Value = 123.90 P8 = Return Pres(psi), Value = 7.77 11:43:19 Magnet Current for MAIN, Imag = 200.1225 A Vtrans = 2.001177 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:43:19 MAIN (V) Voltage Measurement, V = -30.931182 V 11:43:20 Temperature Measurement, Probe Number = 0, T = 26.032000 C 11:43:20 Temperature Measurement, Probe Number = 1, T = 31.333000 C 11:43:21 Temperature Measurement, Probe Number = 2, T = 17.318000 C 11:43:22 Sensor Voltage Measurement, Sensor Number = 0, V = 2.304049 V 11:43:22 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.304049 (V, A, ohm, ...), Measured Value = 28.111794 (C, atm, Hz, ...) 11:43:22 Sensor Voltage Measurement, Sensor Number = 1, V = 2.729516 V 11:43:22 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.729516 (V, A, ohm, ...), Measured Value = 34.021049 (C, atm, Hz, ...) 11:43:23 Sensor Voltage Measurement, Sensor Number = 2, V = 2.656454 V 11:43:23 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.656454 (V, A, ohm, ...), Measured Value = 124.234035 (C, atm, Hz, ...) 11:43:24 Sensor Voltage Measurement, Sensor Number = 3, V = 1.103376 V 11:43:24 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.103376 (V, A, ohm, ...), Measured Value = 7.753177 (C, atm, Hz, ...) 11:43:24 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 26.03 P3 = Coil, Value = 31.33 P4 = Ambient Temp (C), Value = 17.32 P5 = Supply Temp(C), Value = 28.11 P6 = Return Temp(C), Value = 34.02 P7 = Supply Pres(psi), Value = 124.23 P8 = Return Pres(psi), Value = 7.75 11:44:25 Magnet Current for MAIN, Imag = 200.1225 A Vtrans = 2.001177 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:44:25 MAIN (V) Voltage Measurement, V = -30.931603 V 11:44:26 Temperature Measurement, Probe Number = 0, T = 26.027000 C 11:44:27 Temperature Measurement, Probe Number = 1, T = 31.379000 C 11:44:27 Temperature Measurement, Probe Number = 2, T = 17.262000 C 11:44:28 Sensor Voltage Measurement, Sensor Number = 0, V = 2.303637 V 11:44:28 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.303637 (V, A, ohm, ...), Measured Value = 28.106075 (C, atm, Hz, ...) 11:44:29 Sensor Voltage Measurement, Sensor Number = 1, V = 2.729938 V 11:44:29 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.729938 (V, A, ohm, ...), Measured Value = 34.026910 (C, atm, Hz, ...) 11:44:29 Sensor Voltage Measurement, Sensor Number = 2, V = 2.656371 V 11:44:29 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.656371 (V, A, ohm, ...), Measured Value = 124.227840 (C, atm, Hz, ...) 11:44:30 Sensor Voltage Measurement, Sensor Number = 3, V = 1.103415 V 11:44:30 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.103415 (V, A, ohm, ...), Measured Value = 7.756133 (C, atm, Hz, ...) 11:44:30 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 26.03 P3 = Coil, Value = 31.38 P4 = Ambient Temp (C), Value = 17.26 P5 = Supply Temp(C), Value = 28.11 P6 = Return Temp(C), Value = 34.03 P7 = Supply Pres(psi), Value = 124.23 P8 = Return Pres(psi), Value = 7.76 11:45:31 Magnet Current for MAIN, Imag = 200.1223 A Vtrans = 2.001175 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:45:31 MAIN (V) Voltage Measurement, V = -30.931769 V 11:45:32 Temperature Measurement, Probe Number = 0, T = 26.038000 C 11:45:33 Temperature Measurement, Probe Number = 1, T = 31.419000 C 11:45:33 Temperature Measurement, Probe Number = 2, T = 17.258000 C 11:45:34 Sensor Voltage Measurement, Sensor Number = 0, V = 2.303332 V 11:45:34 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.303332 (V, A, ohm, ...), Measured Value = 28.101838 (C, atm, Hz, ...) 11:45:35 Sensor Voltage Measurement, Sensor Number = 1, V = 2.730478 V 11:45:35 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.730478 (V, A, ohm, ...), Measured Value = 34.034413 (C, atm, Hz, ...) 11:45:35 Sensor Voltage Measurement, Sensor Number = 2, V = 2.655240 V 11:45:35 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.655240 (V, A, ohm, ...), Measured Value = 124.142993 (C, atm, Hz, ...) 11:45:36 Sensor Voltage Measurement, Sensor Number = 3, V = 1.103505 V 11:45:36 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.103505 (V, A, ohm, ...), Measured Value = 7.762905 (C, atm, Hz, ...) 11:45:36 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 26.04 P3 = Coil, Value = 31.42 P4 = Ambient Temp (C), Value = 17.26 P5 = Supply Temp(C), Value = 28.10 P6 = Return Temp(C), Value = 34.03 P7 = Supply Pres(psi), Value = 124.14 P8 = Return Pres(psi), Value = 7.76 11:46:37 Magnet Current for MAIN, Imag = 200.1224 A Vtrans = 2.001176 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:46:38 MAIN (V) Voltage Measurement, V = -30.931730 V 11:46:38 Temperature Measurement, Probe Number = 0, T = 26.050000 C 11:46:39 Temperature Measurement, Probe Number = 1, T = 31.377000 C 11:46:40 Temperature Measurement, Probe Number = 2, T = 17.265000 C 11:46:40 Sensor Voltage Measurement, Sensor Number = 0, V = 2.303682 V 11:46:40 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.303682 (V, A, ohm, ...), Measured Value = 28.106693 (C, atm, Hz, ...) 11:46:41 Sensor Voltage Measurement, Sensor Number = 1, V = 2.731351 V 11:46:41 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.731351 (V, A, ohm, ...), Measured Value = 34.046540 (C, atm, Hz, ...) 11:46:42 Sensor Voltage Measurement, Sensor Number = 2, V = 2.664840 V 11:46:42 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.664840 (V, A, ohm, ...), Measured Value = 124.863022 (C, atm, Hz, ...) 11:46:42 Sensor Voltage Measurement, Sensor Number = 3, V = 1.103718 V 11:46:42 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.103718 (V, A, ohm, ...), Measured Value = 7.778820 (C, atm, Hz, ...) 11:46:42 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 26.05 P3 = Coil, Value = 31.38 P4 = Ambient Temp (C), Value = 17.27 P5 = Supply Temp(C), Value = 28.11 P6 = Return Temp(C), Value = 34.05 P7 = Supply Pres(psi), Value = 124.86 P8 = Return Pres(psi), Value = 7.78 11:47:43 Magnet Current for MAIN, Imag = 200.1228 A Vtrans = 2.001180 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:47:44 MAIN (V) Voltage Measurement, V = -30.931603 V 11:47:44 Temperature Measurement, Probe Number = 0, T = 26.062000 C 11:47:45 Temperature Measurement, Probe Number = 1, T = 31.348000 C 11:47:46 Temperature Measurement, Probe Number = 2, T = 17.243000 C 11:47:46 Sensor Voltage Measurement, Sensor Number = 0, V = 2.303048 V 11:47:46 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.303048 (V, A, ohm, ...), Measured Value = 28.097883 (C, atm, Hz, ...) 11:47:47 Sensor Voltage Measurement, Sensor Number = 1, V = 2.732163 V 11:47:47 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.732163 (V, A, ohm, ...), Measured Value = 34.057821 (C, atm, Hz, ...) 11:47:48 Sensor Voltage Measurement, Sensor Number = 2, V = 2.659448 V 11:47:48 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.659448 (V, A, ohm, ...), Measured Value = 124.458630 (C, atm, Hz, ...) 11:47:48 Sensor Voltage Measurement, Sensor Number = 3, V = 1.103641 V 11:47:48 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.103641 (V, A, ohm, ...), Measured Value = 7.773105 (C, atm, Hz, ...) 11:47:49 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 26.06 P3 = Coil, Value = 31.35 P4 = Ambient Temp (C), Value = 17.24 P5 = Supply Temp(C), Value = 28.10 P6 = Return Temp(C), Value = 34.06 P7 = Supply Pres(psi), Value = 124.46 P8 = Return Pres(psi), Value = 7.77 11:48:49 Magnet Current for MAIN, Imag = 200.1223 A Vtrans = 2.001175 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:48:50 MAIN (V) Voltage Measurement, V = -30.930761 V 11:48:51 Temperature Measurement, Probe Number = 0, T = 26.073000 C 11:48:51 Temperature Measurement, Probe Number = 1, T = 31.345000 C 11:48:52 Temperature Measurement, Probe Number = 2, T = 17.267000 C 11:48:52 Sensor Voltage Measurement, Sensor Number = 0, V = 2.301219 V 11:48:53 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.301219 (V, A, ohm, ...), Measured Value = 28.072479 (C, atm, Hz, ...) 11:48:53 Sensor Voltage Measurement, Sensor Number = 1, V = 2.732860 V 11:48:53 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.732860 (V, A, ohm, ...), Measured Value = 34.067496 (C, atm, Hz, ...) 11:48:54 Sensor Voltage Measurement, Sensor Number = 2, V = 2.658279 V 11:48:54 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.658279 (V, A, ohm, ...), Measured Value = 124.370925 (C, atm, Hz, ...) 11:48:55 Sensor Voltage Measurement, Sensor Number = 3, V = 1.103573 V 11:48:55 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.103573 (V, A, ohm, ...), Measured Value = 7.767952 (C, atm, Hz, ...) 11:48:55 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 26.07 P3 = Coil, Value = 31.34 P4 = Ambient Temp (C), Value = 17.27 P5 = Supply Temp(C), Value = 28.07 P6 = Return Temp(C), Value = 34.07 P7 = Supply Pres(psi), Value = 124.37 P8 = Return Pres(psi), Value = 7.77 11:49:55 Magnet Current for MAIN, Imag = 200.1224 A Vtrans = 2.001176 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:49:56 MAIN (V) Voltage Measurement, V = -30.929217 V 11:49:57 Temperature Measurement, Probe Number = 0, T = 26.082000 C 11:49:57 Temperature Measurement, Probe Number = 1, T = 31.316000 C 11:49:58 Temperature Measurement, Probe Number = 2, T = 17.248000 C 11:49:59 Sensor Voltage Measurement, Sensor Number = 0, V = 2.299478 V 11:49:59 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.299478 (V, A, ohm, ...), Measured Value = 28.048311 (C, atm, Hz, ...) 11:49:59 Sensor Voltage Measurement, Sensor Number = 1, V = 2.733557 V 11:49:59 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.733557 (V, A, ohm, ...), Measured Value = 34.077188 (C, atm, Hz, ...) 11:50:00 Sensor Voltage Measurement, Sensor Number = 2, V = 2.655800 V 11:50:00 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.655800 (V, A, ohm, ...), Measured Value = 124.185030 (C, atm, Hz, ...) 11:50:01 Sensor Voltage Measurement, Sensor Number = 3, V = 1.103657 V 11:50:01 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.103657 (V, A, ohm, ...), Measured Value = 7.774245 (C, atm, Hz, ...) 11:50:01 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 26.08 P3 = Coil, Value = 31.32 P4 = Ambient Temp (C), Value = 17.25 P5 = Supply Temp(C), Value = 28.05 P6 = Return Temp(C), Value = 34.08 P7 = Supply Pres(psi), Value = 124.19 P8 = Return Pres(psi), Value = 7.77 11:51:01 Magnet Current for MAIN, Imag = 200.1224 A Vtrans = 2.001176 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:51:02 MAIN (V) Voltage Measurement, V = -30.927290 V 11:51:03 Temperature Measurement, Probe Number = 0, T = 26.067000 C 11:51:03 Temperature Measurement, Probe Number = 1, T = 31.292000 C 11:51:04 Temperature Measurement, Probe Number = 2, T = 17.265000 C 11:51:05 Sensor Voltage Measurement, Sensor Number = 0, V = 2.298394 V 11:51:05 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.298394 (V, A, ohm, ...), Measured Value = 28.033253 (C, atm, Hz, ...) 11:51:05 Sensor Voltage Measurement, Sensor Number = 1, V = 2.734155 V 11:51:06 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.734155 (V, A, ohm, ...), Measured Value = 34.085485 (C, atm, Hz, ...) 11:51:06 Sensor Voltage Measurement, Sensor Number = 2, V = 2.658510 V 11:51:06 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.658510 (V, A, ohm, ...), Measured Value = 124.388280 (C, atm, Hz, ...) 11:51:07 Sensor Voltage Measurement, Sensor Number = 3, V = 1.103340 V 11:51:07 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.103340 (V, A, ohm, ...), Measured Value = 7.750508 (C, atm, Hz, ...) 11:51:07 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 26.07 P3 = Coil, Value = 31.29 P4 = Ambient Temp (C), Value = 17.27 P5 = Supply Temp(C), Value = 28.03 P6 = Return Temp(C), Value = 34.09 P7 = Supply Pres(psi), Value = 124.39 P8 = Return Pres(psi), Value = 7.75 11:52:08 Magnet Current for MAIN, Imag = 200.1224 A Vtrans = 2.001176 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 11:52:08 MAIN (V) Voltage Measurement, V = -30.925376 V 11:52:09 Temperature Measurement, Probe Number = 0, T = 26.064000 C 11:52:10 Temperature Measurement, Probe Number = 1, T = 31.282000 C 11:52:10 Temperature Measurement, Probe Number = 2, T = 17.251000 C 11:52:11 Sensor Voltage Measurement, Sensor Number = 0, V = 2.297506 V 11:52:11 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.297506 (V, A, ohm, ...), Measured Value = 28.020912 (C, atm, Hz, ...) 11:52:12 Sensor Voltage Measurement, Sensor Number = 1, V = 2.734700 V 11:52:12 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.734700 (V, A, ohm, ...), Measured Value = 34.093058 (C, atm, Hz, ...) 11:52:12 Sensor Voltage Measurement, Sensor Number = 2, V = 2.659968 V 11:52:12 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.659968 (V, A, ohm, ...), Measured Value = 124.497623 (C, atm, Hz, ...) 11:52:13 Sensor Voltage Measurement, Sensor Number = 3, V = 1.103523 V 11:52:13 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.103523 (V, A, ohm, ...), Measured Value = 7.764240 (C, atm, Hz, ...) 11:52:13 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.93 P2 = Magnet Core, Value = 26.06 P3 = Coil, Value = 31.28 P4 = Ambient Temp (C), Value = 17.25 P5 = Supply Temp(C), Value = 28.02 P6 = Return Temp(C), Value = 34.09 P7 = Supply Pres(psi), Value = 124.50 P8 = Return Pres(psi), Value = 7.76 11:52:13 Magnet system MAIN current ramping to 0.0000 A... 11:53:19 Magnet system MAIN current ramping to 200.0000 A... 11:54:26 Magnet system MAIN current ramping to 0.0000 A... 11:55:32 Magnet system MAIN current ramping to 200.0000 A... 11:56:38 Magnet system MAIN current ramping to 0.0000 A... 11:57:45 Magnet system MAIN current ramping to 200.0000 A... 11:58:51 Magnet system MAIN current ramping to 0.0000 A... 11:59:57 Magnet system MAIN current ramping to 200.0000 A... 12:01:04 Magnet system MAIN current ramping to 0.0000 A... 12:02:10 Magnet system MAIN current ramping to 200.0000 A... 12:03:17 Magnet system MAIN current ramping to 0.0000 A... 12:04:23 Magnet system MAIN current ramping to 200.0000 A... 12:05:29 Magnet system MAIN current ramping to 0.0000 A... 12:06:35 Magnet system MAIN current ramping to 200.0000 A... 12:07:42 Magnet system MAIN current ramping to 0.0000 A... 12:08:48 Magnet system MAIN current ramping to 200.0000 A... 12:09:54 Magnet system MAIN current ramping to 0.0000 A... 12:11:01 Magnet system MAIN current ramping to 200.0000 A... 12:12:07 Magnet system MAIN current ramping to 0.0000 A... 12:13:13 Magnet system MAIN current ramping to 200.0000 A... 12:14:20 Magnet system MAIN current ramping to 0.0000 A... 12:15:29 Position moved: 0.000000 m 12:15:32 Magnet system MAIN current ramping to 0.0000 A... 12:15:43 Magnet Current for MAIN, Imag = 0.0086 A Vtrans = 0.000038 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:15:43 MAIN (V) Voltage Measurement, V = -0.000653 V 12:15:44 Temperature Measurement, Probe Number = 0, T = 25.918000 C 12:15:45 Temperature Measurement, Probe Number = 1, T = 28.546000 C 12:15:45 Temperature Measurement, Probe Number = 2, T = 17.358000 C 12:15:46 Sensor Voltage Measurement, Sensor Number = 0, V = 2.300574 V 12:15:46 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.300574 (V, A, ohm, ...), Measured Value = 28.063529 (C, atm, Hz, ...) 12:15:47 Sensor Voltage Measurement, Sensor Number = 1, V = 2.469888 V 12:15:47 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.469888 (V, A, ohm, ...), Measured Value = 30.415107 (C, atm, Hz, ...) 12:15:47 Sensor Voltage Measurement, Sensor Number = 2, V = 2.665612 V 12:15:47 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.665612 (V, A, ohm, ...), Measured Value = 124.920893 (C, atm, Hz, ...) 12:15:48 Sensor Voltage Measurement, Sensor Number = 3, V = 1.102195 V 12:15:48 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.102195 (V, A, ohm, ...), Measured Value = 7.664617 (C, atm, Hz, ...) 12:15:48 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.01 P1 = MAIN (V), Value = -0.00 P2 = Magnet Core, Value = 25.92 P3 = Coil, Value = 28.55 P4 = Ambient Temp (C), Value = 17.36 P5 = Supply Temp(C), Value = 28.06 P6 = Return Temp(C), Value = 30.42 P7 = Supply Pres(psi), Value = 124.92 P8 = Return Pres(psi), Value = 7.66 12:15:48 Magnetic Field Measurement Measuring the magnet strength... 12:15:48 Integrated Voltage Measurement... 12:15:49 Magnet Current for MAIN, Imag = 0.0086 A Vtrans = 0.000038 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:15:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.000121381 Vs 12:16:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.000129060 Vs 12:16:06 Magnet Current for MAIN, Imag = 0.0088 A Vtrans = 0.000040 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:16:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.000111473 Vs 12:16:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.000120358 Vs 12:16:21 Magnet Current for MAIN, Imag = 0.0088 A Vtrans = 0.000040 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:16:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.000105497 Vs 12:16:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.000115055 Vs 12:16:36 Magnet Current for MAIN, Imag = 0.0088 A Vtrans = 0.000040 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:16:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.000102356 Vs 12:16:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.000110816 Vs 12:16:51 Magnet Current for MAIN, Imag = 0.0086 A Vtrans = 0.000039 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:16:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.000100401 Vs 12:17:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.000108141 Vs 12:17:05 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.000112454 +- 0.000007498 Vs 12:17:05 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.000112454 +- 0.000007498 Vs BL = -0.00124948 +- 0.00008331 Tm 12:17:09 Position moved: 0.000000 m 12:17:09 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00125 0.00008 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.00125 0.00008 -0.00125 0.00000 12:17:09 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00125 0.00008 SL = -0.0012495 +- 0.0000833 Tm^2/m^n 12:17:09 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0012495 +- 0.0000833 Tm^2/m^n 12:17:12 Position moved: 0.000000 m 12:17:12 Magnet system MAIN current ramping to 20.0000 A... 12:17:29 Magnet Current for MAIN, Imag = 19.9754 A Vtrans = 0.199707 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:17:29 MAIN (V) Voltage Measurement, V = -3.024499 V 12:17:30 Temperature Measurement, Probe Number = 0, T = 25.907000 C 12:17:31 Temperature Measurement, Probe Number = 1, T = 28.105000 C 12:17:31 Temperature Measurement, Probe Number = 2, T = 17.411000 C 12:17:32 Sensor Voltage Measurement, Sensor Number = 0, V = 2.300976 V 12:17:32 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.300976 (V, A, ohm, ...), Measured Value = 28.069108 (C, atm, Hz, ...) 12:17:32 Sensor Voltage Measurement, Sensor Number = 1, V = 2.457479 V 12:17:33 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.457479 (V, A, ohm, ...), Measured Value = 30.242771 (C, atm, Hz, ...) 12:17:33 Sensor Voltage Measurement, Sensor Number = 2, V = 2.666371 V 12:17:33 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.666371 (V, A, ohm, ...), Measured Value = 124.977802 (C, atm, Hz, ...) 12:17:34 Sensor Voltage Measurement, Sensor Number = 3, V = 1.102190 V 12:17:34 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.102190 (V, A, ohm, ...), Measured Value = 7.664235 (C, atm, Hz, ...) 12:17:34 Magnet Test Parameter Measurements P0 = MAIN, Value = 19.98 P1 = MAIN (V), Value = -3.02 P2 = Magnet Core, Value = 25.91 P3 = Coil, Value = 28.11 P4 = Ambient Temp (C), Value = 17.41 P5 = Supply Temp(C), Value = 28.07 P6 = Return Temp(C), Value = 30.24 P7 = Supply Pres(psi), Value = 124.98 P8 = Return Pres(psi), Value = 7.66 12:17:34 Magnetic Field Measurement Measuring the magnet strength... 12:17:34 Integrated Voltage Measurement... 12:17:35 Magnet Current for MAIN, Imag = 19.9752 A Vtrans = 0.199705 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:17:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.007816143 Vs 12:17:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.007821219 Vs 12:17:51 Magnet Current for MAIN, Imag = 19.9753 A Vtrans = 0.199705 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:17:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.007817599 Vs 12:18:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.007824302 Vs 12:18:05 Magnet Current for MAIN, Imag = 19.9751 A Vtrans = 0.199703 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:18:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.007817855 Vs 12:18:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.007824846 Vs 12:18:20 Magnet Current for MAIN, Imag = 19.9754 A Vtrans = 0.199706 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:18:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.007817062 Vs 12:18:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.007825530 Vs 12:18:35 Magnet Current for MAIN, Imag = 19.9755 A Vtrans = 0.199707 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:18:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.007816983 Vs 12:18:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.007824491 Vs 12:18:49 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.007820603 +- 0.000000987 Vs 12:18:49 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.007820603 +- 0.000000987 Vs BL = -0.08689559 +- 0.00001097 Tm 12:18:53 Position moved: 0.000000 m 12:18:53 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.08690 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.08690 0.00001 -0.08690 0.00000 12:18:53 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.08690 0.00001 SL = -0.0868956 +- 0.0000110 Tm^2/m^n 12:18:53 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0868956 +- 0.0000110 Tm^2/m^n 12:18:56 Position moved: 0.000000 m 12:18:56 Magnet system MAIN current ramping to 40.0000 A... 12:19:13 Magnet Current for MAIN, Imag = 39.9585 A Vtrans = 0.399537 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:19:13 MAIN (V) Voltage Measurement, V = -6.039922 V 12:19:14 Temperature Measurement, Probe Number = 0, T = 25.908000 C 12:19:15 Temperature Measurement, Probe Number = 1, T = 27.512000 C 12:19:15 Temperature Measurement, Probe Number = 2, T = 17.385000 C 12:19:16 Sensor Voltage Measurement, Sensor Number = 0, V = 2.301923 V 12:19:16 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.301923 (V, A, ohm, ...), Measured Value = 28.082260 (C, atm, Hz, ...) 12:19:17 Sensor Voltage Measurement, Sensor Number = 1, V = 2.425909 V 12:19:17 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.425909 (V, A, ohm, ...), Measured Value = 29.804286 (C, atm, Hz, ...) 12:19:17 Sensor Voltage Measurement, Sensor Number = 2, V = 2.650888 V 12:19:18 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.650888 (V, A, ohm, ...), Measured Value = 123.816578 (C, atm, Hz, ...) 12:19:18 Sensor Voltage Measurement, Sensor Number = 3, V = 1.102394 V 12:19:18 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.102394 (V, A, ohm, ...), Measured Value = 7.679587 (C, atm, Hz, ...) 12:19:18 Magnet Test Parameter Measurements P0 = MAIN, Value = 39.96 P1 = MAIN (V), Value = -6.04 P2 = Magnet Core, Value = 25.91 P3 = Coil, Value = 27.51 P4 = Ambient Temp (C), Value = 17.39 P5 = Supply Temp(C), Value = 28.08 P6 = Return Temp(C), Value = 29.80 P7 = Supply Pres(psi), Value = 123.82 P8 = Return Pres(psi), Value = 7.68 12:19:18 Magnetic Field Measurement Measuring the magnet strength... 12:19:18 Integrated Voltage Measurement... 12:19:19 Magnet Current for MAIN, Imag = 39.9584 A Vtrans = 0.399536 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:19:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.015543194 Vs 12:19:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.015553439 Vs 12:19:35 Magnet Current for MAIN, Imag = 39.9584 A Vtrans = 0.399536 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:19:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.015547810 Vs 12:19:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.015556406 Vs 12:19:50 Magnet Current for MAIN, Imag = 39.9584 A Vtrans = 0.399536 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:19:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.015548768 Vs 12:20:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.015555043 Vs 12:20:05 Magnet Current for MAIN, Imag = 39.9582 A Vtrans = 0.399534 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:20:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.015550224 Vs 12:20:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.015557397 Vs 12:20:19 Magnet Current for MAIN, Imag = 39.9580 A Vtrans = 0.399532 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:20:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.015549708 Vs 12:20:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.015555267 Vs 12:20:34 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.015551726 +- 0.000001829 Vs 12:20:34 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.015551726 +- 0.000001829 Vs BL = -0.17279695 +- 0.00002032 Tm 12:20:38 Position moved: 0.000000 m 12:20:38 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.17280 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.17280 0.00002 -0.17280 0.00000 12:20:38 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.17280 0.00002 SL = -0.1727970 +- 0.0000203 Tm^2/m^n 12:20:38 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1727970 +- 0.0000203 Tm^2/m^n 12:20:41 Position moved: 0.000000 m 12:20:41 Magnet system MAIN current ramping to 60.0000 A... 12:20:57 Magnet Current for MAIN, Imag = 60.0086 A Vtrans = 0.600038 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:20:58 MAIN (V) Voltage Measurement, V = -9.069518 V 12:20:59 Temperature Measurement, Probe Number = 0, T = 25.885000 C 12:20:59 Temperature Measurement, Probe Number = 1, T = 27.033000 C 12:21:00 Temperature Measurement, Probe Number = 2, T = 17.405000 C 12:21:01 Sensor Voltage Measurement, Sensor Number = 0, V = 2.302348 V 12:21:01 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.302348 (V, A, ohm, ...), Measured Value = 28.088174 (C, atm, Hz, ...) 12:21:01 Sensor Voltage Measurement, Sensor Number = 1, V = 2.387114 V 12:21:01 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.387114 (V, A, ohm, ...), Measured Value = 29.265472 (C, atm, Hz, ...) 12:21:02 Sensor Voltage Measurement, Sensor Number = 2, V = 2.664465 V 12:21:02 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.664465 (V, A, ohm, ...), Measured Value = 124.834905 (C, atm, Hz, ...) 12:21:03 Sensor Voltage Measurement, Sensor Number = 3, V = 1.101967 V 12:21:03 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.101967 (V, A, ohm, ...), Measured Value = 7.647555 (C, atm, Hz, ...) 12:21:03 Magnet Test Parameter Measurements P0 = MAIN, Value = 60.01 P1 = MAIN (V), Value = -9.07 P2 = Magnet Core, Value = 25.89 P3 = Coil, Value = 27.03 P4 = Ambient Temp (C), Value = 17.41 P5 = Supply Temp(C), Value = 28.09 P6 = Return Temp(C), Value = 29.27 P7 = Supply Pres(psi), Value = 124.83 P8 = Return Pres(psi), Value = 7.65 12:21:03 Magnetic Field Measurement Measuring the magnet strength... 12:21:03 Integrated Voltage Measurement... 12:21:04 Magnet Current for MAIN, Imag = 60.0083 A Vtrans = 0.600035 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:21:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.023309047 Vs 12:21:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.023316477 Vs 12:21:19 Magnet Current for MAIN, Imag = 60.0084 A Vtrans = 0.600037 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:21:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.023317942 Vs 12:21:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.023320658 Vs 12:21:34 Magnet Current for MAIN, Imag = 60.0085 A Vtrans = 0.600037 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:21:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.023318722 Vs 12:21:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.023323002 Vs 12:21:49 Magnet Current for MAIN, Imag = 60.0084 A Vtrans = 0.600036 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:21:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.023318811 Vs 12:22:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.023322275 Vs 12:22:04 Magnet Current for MAIN, Imag = 60.0085 A Vtrans = 0.600037 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:22:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.023322517 Vs 12:22:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.023322411 Vs 12:22:18 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.023319186 +- 0.000003367 Vs 12:22:18 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.023319186 +- 0.000003367 Vs BL = -0.25910207 +- 0.00003741 Tm 12:22:22 Position moved: 0.000000 m 12:22:22 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.25910 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.25910 0.00004 -0.25910 0.00000 12:22:22 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.25910 0.00004 SL = -0.2591021 +- 0.0000374 Tm^2/m^n 12:22:22 Magnet Strength Measurement Harmonic Number = 1 SL = -0.2591021 +- 0.0000374 Tm^2/m^n 12:22:25 Position moved: 0.000000 m 12:22:25 Magnet system MAIN current ramping to 80.0000 A... 12:22:42 Magnet Current for MAIN, Imag = 79.9970 A Vtrans = 0.799922 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:22:42 MAIN (V) Voltage Measurement, V = -12.100347 V 12:22:43 Temperature Measurement, Probe Number = 0, T = 25.841000 C 12:22:44 Temperature Measurement, Probe Number = 1, T = 26.998000 C 12:22:44 Temperature Measurement, Probe Number = 2, T = 17.389000 C 12:22:45 Sensor Voltage Measurement, Sensor Number = 0, V = 2.303278 V 12:22:45 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.303278 (V, A, ohm, ...), Measured Value = 28.101079 (C, atm, Hz, ...) 12:22:46 Sensor Voltage Measurement, Sensor Number = 1, V = 2.353847 V 12:22:46 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.353847 (V, A, ohm, ...), Measured Value = 28.803436 (C, atm, Hz, ...) 12:22:46 Sensor Voltage Measurement, Sensor Number = 2, V = 2.659790 V 12:22:46 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.659790 (V, A, ohm, ...), Measured Value = 124.484273 (C, atm, Hz, ...) 12:22:47 Sensor Voltage Measurement, Sensor Number = 3, V = 1.102230 V 12:22:47 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.102230 (V, A, ohm, ...), Measured Value = 7.667287 (C, atm, Hz, ...) 12:22:47 Magnet Test Parameter Measurements P0 = MAIN, Value = 80.00 P1 = MAIN (V), Value = -12.10 P2 = Magnet Core, Value = 25.84 P3 = Coil, Value = 27.00 P4 = Ambient Temp (C), Value = 17.39 P5 = Supply Temp(C), Value = 28.10 P6 = Return Temp(C), Value = 28.80 P7 = Supply Pres(psi), Value = 124.48 P8 = Return Pres(psi), Value = 7.67 12:22:47 Magnetic Field Measurement Measuring the magnet strength... 12:22:47 Integrated Voltage Measurement... 12:22:48 Magnet Current for MAIN, Imag = 79.9971 A Vtrans = 0.799923 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:22:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.031058568 Vs 12:23:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.031060668 Vs 12:23:04 Magnet Current for MAIN, Imag = 79.9971 A Vtrans = 0.799923 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:23:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.031068712 Vs 12:23:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.031070743 Vs 12:23:19 Magnet Current for MAIN, Imag = 79.9973 A Vtrans = 0.799925 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:23:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.031068431 Vs 12:23:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.031073204 Vs 12:23:33 Magnet Current for MAIN, Imag = 79.9969 A Vtrans = 0.799922 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:23:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.031069048 Vs 12:23:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.031074044 Vs 12:23:48 Magnet Current for MAIN, Imag = 79.9969 A Vtrans = 0.799921 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:23:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.031069179 Vs 12:24:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.031078727 Vs 12:24:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.031069132 +- 0.000004956 Vs 12:24:02 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.031069132 +- 0.000004956 Vs BL = -0.34521258 +- 0.00005506 Tm 12:24:06 Position moved: 0.000000 m 12:24:06 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.34521 0.00006 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.34521 0.00006 -0.34521 0.00000 12:24:06 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.34521 0.00006 SL = -0.3452126 +- 0.0000551 Tm^2/m^n 12:24:07 Magnet Strength Measurement Harmonic Number = 1 SL = -0.3452126 +- 0.0000551 Tm^2/m^n 12:24:09 Position moved: 0.000000 m 12:24:09 Magnet system MAIN current ramping to 100.0000 A... 12:24:26 Magnet Current for MAIN, Imag = 100.0468 A Vtrans = 1.000420 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:24:27 MAIN (V) Voltage Measurement, V = -15.153857 V 12:24:27 Temperature Measurement, Probe Number = 0, T = 25.826000 C 12:24:28 Temperature Measurement, Probe Number = 1, T = 27.007000 C 12:24:29 Temperature Measurement, Probe Number = 2, T = 17.367000 C 12:24:29 Sensor Voltage Measurement, Sensor Number = 0, V = 2.303804 V 12:24:29 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.303804 (V, A, ohm, ...), Measured Value = 28.108388 (C, atm, Hz, ...) 12:24:30 Sensor Voltage Measurement, Sensor Number = 1, V = 2.330892 V 12:24:30 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.330892 (V, A, ohm, ...), Measured Value = 28.484608 (C, atm, Hz, ...) 12:24:31 Sensor Voltage Measurement, Sensor Number = 2, V = 2.655741 V 12:24:31 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.655741 (V, A, ohm, ...), Measured Value = 124.180552 (C, atm, Hz, ...) 12:24:31 Sensor Voltage Measurement, Sensor Number = 3, V = 1.101859 V 12:24:31 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.101859 (V, A, ohm, ...), Measured Value = 7.639448 (C, atm, Hz, ...) 12:24:31 Magnet Test Parameter Measurements P0 = MAIN, Value = 100.05 P1 = MAIN (V), Value = -15.15 P2 = Magnet Core, Value = 25.83 P3 = Coil, Value = 27.01 P4 = Ambient Temp (C), Value = 17.37 P5 = Supply Temp(C), Value = 28.11 P6 = Return Temp(C), Value = 28.48 P7 = Supply Pres(psi), Value = 124.18 P8 = Return Pres(psi), Value = 7.64 12:24:31 Magnetic Field Measurement Measuring the magnet strength... 12:24:32 Integrated Voltage Measurement... 12:24:32 Magnet Current for MAIN, Imag = 100.0469 A Vtrans = 1.000421 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:24:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.038822939 Vs 12:24:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.038811469 Vs 12:24:48 Magnet Current for MAIN, Imag = 100.0466 A Vtrans = 1.000418 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:24:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.038833918 Vs 12:25:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.038826668 Vs 12:25:03 Magnet Current for MAIN, Imag = 100.0470 A Vtrans = 1.000422 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:25:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.038831160 Vs 12:25:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.038829716 Vs 12:25:18 Magnet Current for MAIN, Imag = 100.0468 A Vtrans = 1.000420 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:25:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.038833420 Vs 12:25:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.038835130 Vs 12:25:32 Magnet Current for MAIN, Imag = 100.0468 A Vtrans = 1.000420 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:25:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.038834880 Vs 12:25:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.038835405 Vs 12:25:47 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.038829470 +- 0.000006439 Vs 12:25:47 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.038829470 +- 0.000006439 Vs BL = -0.43143856 +- 0.00007155 Tm 12:25:51 Position moved: 0.000000 m 12:25:51 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.43144 0.00007 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.43144 0.00007 -0.43144 0.00000 12:25:51 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.43144 0.00007 SL = -0.4314386 +- 0.0000715 Tm^2/m^n 12:25:51 Magnet Strength Measurement Harmonic Number = 1 SL = -0.4314386 +- 0.0000715 Tm^2/m^n 12:25:54 Position moved: 0.000000 m 12:25:54 Magnet system MAIN current ramping to 120.0000 A... 12:26:10 Magnet Current for MAIN, Imag = 120.0375 A Vtrans = 1.200327 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:26:11 MAIN (V) Voltage Measurement, V = -18.215494 V 12:26:12 Temperature Measurement, Probe Number = 0, T = 25.809000 C 12:26:12 Temperature Measurement, Probe Number = 1, T = 27.120000 C 12:26:13 Temperature Measurement, Probe Number = 2, T = 17.408000 C 12:26:13 Sensor Voltage Measurement, Sensor Number = 0, V = 2.304014 V 12:26:14 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.304014 (V, A, ohm, ...), Measured Value = 28.111300 (C, atm, Hz, ...) 12:26:14 Sensor Voltage Measurement, Sensor Number = 1, V = 2.320881 V 12:26:14 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.320881 (V, A, ohm, ...), Measured Value = 28.345568 (C, atm, Hz, ...) 12:26:15 Sensor Voltage Measurement, Sensor Number = 2, V = 2.649907 V 12:26:15 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.649907 (V, A, ohm, ...), Measured Value = 123.742988 (C, atm, Hz, ...) 12:26:16 Sensor Voltage Measurement, Sensor Number = 3, V = 1.101789 V 12:26:16 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.101789 (V, A, ohm, ...), Measured Value = 7.634205 (C, atm, Hz, ...) 12:26:16 Magnet Test Parameter Measurements P0 = MAIN, Value = 120.04 P1 = MAIN (V), Value = -18.22 P2 = Magnet Core, Value = 25.81 P3 = Coil, Value = 27.12 P4 = Ambient Temp (C), Value = 17.41 P5 = Supply Temp(C), Value = 28.11 P6 = Return Temp(C), Value = 28.35 P7 = Supply Pres(psi), Value = 123.74 P8 = Return Pres(psi), Value = 7.63 12:26:16 Magnetic Field Measurement Measuring the magnet strength... 12:26:16 Integrated Voltage Measurement... 12:26:17 Magnet Current for MAIN, Imag = 120.0377 A Vtrans = 1.200329 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:26:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.046518454 Vs 12:26:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.046494707 Vs 12:26:32 Magnet Current for MAIN, Imag = 120.0379 A Vtrans = 1.200331 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:26:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.046523937 Vs 12:26:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.046513971 Vs 12:26:47 Magnet Current for MAIN, Imag = 120.0375 A Vtrans = 1.200327 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:26:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.046521135 Vs 12:27:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.046514946 Vs 12:27:02 Magnet Current for MAIN, Imag = 120.0380 A Vtrans = 1.200332 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:27:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.046521809 Vs 12:27:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.046518278 Vs 12:27:17 Magnet Current for MAIN, Imag = 120.0382 A Vtrans = 1.200335 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:27:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.046520407 Vs 12:27:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.046521236 Vs 12:27:31 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.046516888 +- 0.000005240 Vs 12:27:31 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.046516888 +- 0.000005240 Vs BL = -0.51685431 +- 0.00005822 Tm 12:27:35 Position moved: 0.000000 m 12:27:35 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.51685 0.00006 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.51685 0.00006 -0.51685 0.00000 12:27:35 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.51685 0.00006 SL = -0.5168543 +- 0.0000582 Tm^2/m^n 12:27:35 Magnet Strength Measurement Harmonic Number = 1 SL = -0.5168543 +- 0.0000582 Tm^2/m^n 12:27:38 Position moved: 0.000000 m 12:27:38 Magnet system MAIN current ramping to 140.0000 A... 12:27:55 Magnet Current for MAIN, Imag = 140.0819 A Vtrans = 1.400771 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:27:55 MAIN (V) Voltage Measurement, V = -21.308023 V 12:27:56 Temperature Measurement, Probe Number = 0, T = 25.788000 C 12:27:57 Temperature Measurement, Probe Number = 1, T = 27.394000 C 12:27:57 Temperature Measurement, Probe Number = 2, T = 17.402000 C 12:27:58 Sensor Voltage Measurement, Sensor Number = 0, V = 2.304126 V 12:27:58 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.304126 (V, A, ohm, ...), Measured Value = 28.112854 (C, atm, Hz, ...) 12:27:59 Sensor Voltage Measurement, Sensor Number = 1, V = 2.323494 V 12:27:59 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.323494 (V, A, ohm, ...), Measured Value = 28.381864 (C, atm, Hz, ...) 12:27:59 Sensor Voltage Measurement, Sensor Number = 2, V = 2.661328 V 12:27:59 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.661328 (V, A, ohm, ...), Measured Value = 124.599623 (C, atm, Hz, ...) 12:28:00 Sensor Voltage Measurement, Sensor Number = 3, V = 1.101853 V 12:28:00 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.101853 (V, A, ohm, ...), Measured Value = 7.638975 (C, atm, Hz, ...) 12:28:00 Magnet Test Parameter Measurements P0 = MAIN, Value = 140.08 P1 = MAIN (V), Value = -21.31 P2 = Magnet Core, Value = 25.79 P3 = Coil, Value = 27.39 P4 = Ambient Temp (C), Value = 17.40 P5 = Supply Temp(C), Value = 28.11 P6 = Return Temp(C), Value = 28.38 P7 = Supply Pres(psi), Value = 124.60 P8 = Return Pres(psi), Value = 7.64 12:28:00 Magnetic Field Measurement Measuring the magnet strength... 12:28:00 Integrated Voltage Measurement... 12:28:01 Magnet Current for MAIN, Imag = 140.0819 A Vtrans = 1.400771 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:28:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.054135637 Vs 12:28:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.054149268 Vs 12:28:17 Magnet Current for MAIN, Imag = 140.0821 A Vtrans = 1.400773 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:28:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.054144887 Vs 12:28:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.054155534 Vs 12:28:32 Magnet Current for MAIN, Imag = 140.0820 A Vtrans = 1.400772 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:28:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.054155379 Vs 12:28:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.054157476 Vs 12:28:46 Magnet Current for MAIN, Imag = 140.0819 A Vtrans = 1.400771 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:28:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.054156855 Vs 12:29:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.054157463 Vs 12:29:02 Magnet Current for MAIN, Imag = 140.0820 A Vtrans = 1.400772 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:29:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.054153121 Vs 12:29:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.054162850 Vs 12:29:16 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.054152847 +- 0.000005879 Vs 12:29:16 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.054152847 +- 0.000005879 Vs BL = -0.60169830 +- 0.00006532 Tm 12:29:20 Position moved: 0.000000 m 12:29:20 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.60170 0.00007 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.60170 0.00007 -0.60170 0.00000 12:29:20 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.60170 0.00007 SL = -0.6016983 +- 0.0000653 Tm^2/m^n 12:29:20 Magnet Strength Measurement Harmonic Number = 1 SL = -0.6016983 +- 0.0000653 Tm^2/m^n 12:29:23 Position moved: 0.000000 m 12:29:23 Magnet system MAIN current ramping to 160.0000 A... 12:29:40 Magnet Current for MAIN, Imag = 160.0900 A Vtrans = 1.600852 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:29:40 MAIN (V) Voltage Measurement, V = -24.421426 V 12:29:41 Temperature Measurement, Probe Number = 0, T = 25.778000 C 12:29:42 Temperature Measurement, Probe Number = 1, T = 27.756000 C 12:29:42 Temperature Measurement, Probe Number = 2, T = 17.380000 C 12:29:43 Sensor Voltage Measurement, Sensor Number = 0, V = 2.304710 V 12:29:43 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.304710 (V, A, ohm, ...), Measured Value = 28.120975 (C, atm, Hz, ...) 12:29:44 Sensor Voltage Measurement, Sensor Number = 1, V = 2.338277 V 12:29:44 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.338277 (V, A, ohm, ...), Measured Value = 28.587178 (C, atm, Hz, ...) 12:29:44 Sensor Voltage Measurement, Sensor Number = 2, V = 2.648877 V 12:29:45 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.648877 (V, A, ohm, ...), Measured Value = 123.665767 (C, atm, Hz, ...) 12:29:45 Sensor Voltage Measurement, Sensor Number = 3, V = 1.101676 V 12:29:45 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.101676 (V, A, ohm, ...), Measured Value = 7.625723 (C, atm, Hz, ...) 12:29:45 Magnet Test Parameter Measurements P0 = MAIN, Value = 160.09 P1 = MAIN (V), Value = -24.42 P2 = Magnet Core, Value = 25.78 P3 = Coil, Value = 27.76 P4 = Ambient Temp (C), Value = 17.38 P5 = Supply Temp(C), Value = 28.12 P6 = Return Temp(C), Value = 28.59 P7 = Supply Pres(psi), Value = 123.67 P8 = Return Pres(psi), Value = 7.63 12:29:45 Magnetic Field Measurement Measuring the magnet strength... 12:29:45 Integrated Voltage Measurement... 12:29:46 Magnet Current for MAIN, Imag = 160.0897 A Vtrans = 1.600849 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:29:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.061633970 Vs 12:30:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.061655605 Vs 12:30:02 Magnet Current for MAIN, Imag = 160.0895 A Vtrans = 1.600847 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:30:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.061642488 Vs 12:30:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.061653939 Vs 12:30:17 Magnet Current for MAIN, Imag = 160.0897 A Vtrans = 1.600849 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:30:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.061652831 Vs 12:30:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.061660374 Vs 12:30:32 Magnet Current for MAIN, Imag = 160.0895 A Vtrans = 1.600847 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:30:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.061649299 Vs 12:30:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.061652281 Vs 12:30:46 Magnet Current for MAIN, Imag = 160.0897 A Vtrans = 1.600849 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:30:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.061653539 Vs 12:31:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.061653188 Vs 12:31:00 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.061650751 +- 0.000004076 Vs 12:31:01 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.061650751 +- 0.000004076 Vs BL = -0.68500835 +- 0.00004529 Tm 12:31:04 Position moved: 0.000000 m 12:31:04 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.68501 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.68501 0.00005 -0.68501 0.00000 12:31:05 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.68501 0.00005 SL = -0.6850083 +- 0.0000453 Tm^2/m^n 12:31:05 Magnet Strength Measurement Harmonic Number = 1 SL = -0.6850083 +- 0.0000453 Tm^2/m^n 12:31:07 Position moved: 0.000000 m 12:31:08 Magnet system MAIN current ramping to 180.0000 A... 12:31:24 Magnet Current for MAIN, Imag = 180.1375 A Vtrans = 1.801327 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:31:25 MAIN (V) Voltage Measurement, V = -27.571109 V 12:31:25 Temperature Measurement, Probe Number = 0, T = 25.769000 C 12:31:26 Temperature Measurement, Probe Number = 1, T = 28.287000 C 12:31:27 Temperature Measurement, Probe Number = 2, T = 17.410000 C 12:31:27 Sensor Voltage Measurement, Sensor Number = 0, V = 2.305671 V 12:31:27 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.305671 (V, A, ohm, ...), Measured Value = 28.134321 (C, atm, Hz, ...) 12:31:28 Sensor Voltage Measurement, Sensor Number = 1, V = 2.361527 V 12:31:28 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.361527 (V, A, ohm, ...), Measured Value = 28.910101 (C, atm, Hz, ...) 12:31:29 Sensor Voltage Measurement, Sensor Number = 2, V = 2.656159 V 12:31:29 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.656159 (V, A, ohm, ...), Measured Value = 124.211917 (C, atm, Hz, ...) 12:31:29 Sensor Voltage Measurement, Sensor Number = 3, V = 1.101811 V 12:31:29 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.101811 (V, A, ohm, ...), Measured Value = 7.635825 (C, atm, Hz, ...) 12:31:29 Magnet Test Parameter Measurements P0 = MAIN, Value = 180.14 P1 = MAIN (V), Value = -27.57 P2 = Magnet Core, Value = 25.77 P3 = Coil, Value = 28.29 P4 = Ambient Temp (C), Value = 17.41 P5 = Supply Temp(C), Value = 28.13 P6 = Return Temp(C), Value = 28.91 P7 = Supply Pres(psi), Value = 124.21 P8 = Return Pres(psi), Value = 7.64 12:31:30 Magnetic Field Measurement Measuring the magnet strength... 12:31:30 Integrated Voltage Measurement... 12:31:30 Magnet Current for MAIN, Imag = 180.1375 A Vtrans = 1.801327 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:31:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.068870212 Vs 12:31:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.068893953 Vs 12:31:46 Magnet Current for MAIN, Imag = 180.1375 A Vtrans = 1.801327 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:31:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.068882848 Vs 12:32:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.068889035 Vs 12:32:01 Magnet Current for MAIN, Imag = 180.1371 A Vtrans = 1.801324 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:32:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.068886054 Vs 12:32:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.068889904 Vs 12:32:16 Magnet Current for MAIN, Imag = 180.1376 A Vtrans = 1.801329 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:32:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.068881683 Vs 12:32:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.068898762 Vs 12:32:30 Magnet Current for MAIN, Imag = 180.1374 A Vtrans = 1.801326 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:32:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.068892093 Vs 12:32:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.068897107 Vs 12:32:45 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.068888165 +- 0.000004186 Vs 12:32:45 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.068888165 +- 0.000004186 Vs BL = -0.76542406 +- 0.00004651 Tm 12:32:49 Position moved: 0.000000 m 12:32:49 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.76542 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.76542 0.00005 -0.76542 0.00000 12:32:49 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.76542 0.00005 SL = -0.7654241 +- 0.0000465 Tm^2/m^n 12:32:49 Magnet Strength Measurement Harmonic Number = 1 SL = -0.7654241 +- 0.0000465 Tm^2/m^n 12:32:52 Position moved: 0.000000 m 12:32:52 Magnet system MAIN current ramping to 200.0000 A... 12:33:09 Magnet Current for MAIN, Imag = 200.1229 A Vtrans = 2.001181 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:33:09 MAIN (V) Voltage Measurement, V = -30.746144 V 12:33:10 Temperature Measurement, Probe Number = 0, T = 25.767000 C 12:33:10 Temperature Measurement, Probe Number = 1, T = 28.907000 C 12:33:11 Temperature Measurement, Probe Number = 2, T = 17.407000 C 12:33:12 Sensor Voltage Measurement, Sensor Number = 0, V = 2.305278 V 12:33:12 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.305278 (V, A, ohm, ...), Measured Value = 28.128865 (C, atm, Hz, ...) 12:33:12 Sensor Voltage Measurement, Sensor Number = 1, V = 2.393451 V 12:33:13 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.393451 (V, A, ohm, ...), Measured Value = 29.353493 (C, atm, Hz, ...) 12:33:13 Sensor Voltage Measurement, Sensor Number = 2, V = 2.648623 V 12:33:13 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.648623 (V, A, ohm, ...), Measured Value = 123.646703 (C, atm, Hz, ...) 12:33:14 Sensor Voltage Measurement, Sensor Number = 3, V = 1.101970 V 12:33:14 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.101970 (V, A, ohm, ...), Measured Value = 7.647743 (C, atm, Hz, ...) 12:33:14 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.75 P2 = Magnet Core, Value = 25.77 P3 = Coil, Value = 28.91 P4 = Ambient Temp (C), Value = 17.41 P5 = Supply Temp(C), Value = 28.13 P6 = Return Temp(C), Value = 29.35 P7 = Supply Pres(psi), Value = 123.65 P8 = Return Pres(psi), Value = 7.65 12:33:14 Magnetic Field Measurement Measuring the magnet strength... 12:33:14 Integrated Voltage Measurement... 12:33:15 Magnet Current for MAIN, Imag = 200.1228 A Vtrans = 2.001180 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:33:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.075436762 Vs 12:33:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.075460198 Vs 12:33:31 Magnet Current for MAIN, Imag = 200.1229 A Vtrans = 2.001181 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:33:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.075457989 Vs 12:33:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.075467177 Vs 12:33:45 Magnet Current for MAIN, Imag = 200.1232 A Vtrans = 2.001184 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:33:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.075454564 Vs 12:33:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.075468760 Vs 12:34:00 Magnet Current for MAIN, Imag = 200.1226 A Vtrans = 2.001179 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:34:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.075464253 Vs 12:34:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.075462756 Vs 12:34:15 Magnet Current for MAIN, Imag = 200.1226 A Vtrans = 2.001179 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:34:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.075464271 Vs 12:34:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.075470732 Vs 12:34:29 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.075460746 +- 0.000006449 Vs 12:34:29 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.075460746 +- 0.000006449 Vs BL = -0.83845274 +- 0.00007165 Tm 12:34:33 Position moved: 0.000000 m 12:34:33 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.83845 0.00007 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.83845 0.00007 -0.83845 0.00000 12:34:33 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.83845 0.00007 SL = -0.8384527 +- 0.0000717 Tm^2/m^n 12:34:33 Magnet Strength Measurement Harmonic Number = 1 SL = -0.8384527 +- 0.0000717 Tm^2/m^n 12:34:36 Position moved: 0.000000 m 12:34:36 Magnet system MAIN current ramping to 180.0000 A... 12:34:53 Magnet Current for MAIN, Imag = 180.1380 A Vtrans = 1.801332 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:34:53 MAIN (V) Voltage Measurement, V = -27.760447 V 12:34:54 Temperature Measurement, Probe Number = 0, T = 25.778000 C 12:34:55 Temperature Measurement, Probe Number = 1, T = 29.544000 C 12:34:55 Temperature Measurement, Probe Number = 2, T = 17.427000 C 12:34:56 Sensor Voltage Measurement, Sensor Number = 0, V = 2.306449 V 12:34:56 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.306449 (V, A, ohm, ...), Measured Value = 28.145125 (C, atm, Hz, ...) 12:34:57 Sensor Voltage Measurement, Sensor Number = 1, V = 2.432686 V 12:34:57 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.432686 (V, A, ohm, ...), Measured Value = 29.898417 (C, atm, Hz, ...) 12:34:57 Sensor Voltage Measurement, Sensor Number = 2, V = 2.663710 V 12:34:57 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.663710 (V, A, ohm, ...), Measured Value = 124.778272 (C, atm, Hz, ...) 12:34:58 Sensor Voltage Measurement, Sensor Number = 3, V = 1.102122 V 12:34:58 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.102122 (V, A, ohm, ...), Measured Value = 7.659180 (C, atm, Hz, ...) 12:34:58 Magnet Test Parameter Measurements P0 = MAIN, Value = 180.14 P1 = MAIN (V), Value = -27.76 P2 = Magnet Core, Value = 25.78 P3 = Coil, Value = 29.54 P4 = Ambient Temp (C), Value = 17.43 P5 = Supply Temp(C), Value = 28.15 P6 = Return Temp(C), Value = 29.90 P7 = Supply Pres(psi), Value = 124.78 P8 = Return Pres(psi), Value = 7.66 12:34:58 Magnetic Field Measurement Measuring the magnet strength... 12:34:58 Integrated Voltage Measurement... 12:34:59 Magnet Current for MAIN, Imag = 180.1382 A Vtrans = 1.801334 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:35:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.069167486 Vs 12:35:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.069150400 Vs 12:35:15 Magnet Current for MAIN, Imag = 180.1384 A Vtrans = 1.801336 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:35:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.069151321 Vs 12:35:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.069152075 Vs 12:35:30 Magnet Current for MAIN, Imag = 180.1383 A Vtrans = 1.801335 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:35:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.069150723 Vs 12:35:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.069149471 Vs 12:35:44 Magnet Current for MAIN, Imag = 180.1380 A Vtrans = 1.801332 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:35:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.069148789 Vs 12:35:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.069154635 Vs 12:35:59 Magnet Current for MAIN, Imag = 180.1380 A Vtrans = 1.801332 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:36:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.069146168 Vs 12:36:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.069153398 Vs 12:36:13 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.069152447 +- 0.000003344 Vs 12:36:13 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.069152447 +- 0.000003344 Vs BL = -0.76836052 +- 0.00003716 Tm 12:36:17 Position moved: 0.000000 m 12:36:17 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.76836 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.76836 0.00004 -0.76836 0.00000 12:36:17 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.76836 0.00004 SL = -0.7683605 +- 0.0000372 Tm^2/m^n 12:36:17 Magnet Strength Measurement Harmonic Number = 1 SL = -0.7683605 +- 0.0000372 Tm^2/m^n 12:36:20 Position moved: 0.000000 m 12:36:20 Magnet system MAIN current ramping to 160.0000 A... 12:36:37 Magnet Current for MAIN, Imag = 160.0905 A Vtrans = 1.600857 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:36:37 MAIN (V) Voltage Measurement, V = -24.638556 V 12:36:38 Temperature Measurement, Probe Number = 0, T = 25.790000 C 12:36:39 Temperature Measurement, Probe Number = 1, T = 30.053000 C 12:36:39 Temperature Measurement, Probe Number = 2, T = 17.397000 C 12:36:40 Sensor Voltage Measurement, Sensor Number = 0, V = 2.305988 V 12:36:40 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.305988 (V, A, ohm, ...), Measured Value = 28.138717 (C, atm, Hz, ...) 12:36:41 Sensor Voltage Measurement, Sensor Number = 1, V = 2.476647 V 12:36:41 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.476647 (V, A, ohm, ...), Measured Value = 30.508990 (C, atm, Hz, ...) 12:36:41 Sensor Voltage Measurement, Sensor Number = 2, V = 2.664341 V 12:36:41 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.664341 (V, A, ohm, ...), Measured Value = 124.825560 (C, atm, Hz, ...) 12:36:42 Sensor Voltage Measurement, Sensor Number = 3, V = 1.102485 V 12:36:42 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.102485 (V, A, ohm, ...), Measured Value = 7.686352 (C, atm, Hz, ...) 12:36:42 Magnet Test Parameter Measurements P0 = MAIN, Value = 160.09 P1 = MAIN (V), Value = -24.64 P2 = Magnet Core, Value = 25.79 P3 = Coil, Value = 30.05 P4 = Ambient Temp (C), Value = 17.40 P5 = Supply Temp(C), Value = 28.14 P6 = Return Temp(C), Value = 30.51 P7 = Supply Pres(psi), Value = 124.83 P8 = Return Pres(psi), Value = 7.69 12:36:42 Magnetic Field Measurement Measuring the magnet strength... 12:36:42 Integrated Voltage Measurement... 12:36:43 Magnet Current for MAIN, Imag = 160.0914 A Vtrans = 1.600866 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:36:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.061931397 Vs 12:36:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.061900357 Vs 12:36:59 Magnet Current for MAIN, Imag = 160.0910 A Vtrans = 1.600862 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:37:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.061899372 Vs 12:37:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.061892696 Vs 12:37:14 Magnet Current for MAIN, Imag = 160.0916 A Vtrans = 1.600868 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:37:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.061889363 Vs 12:37:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.061898049 Vs 12:37:28 Magnet Current for MAIN, Imag = 160.0910 A Vtrans = 1.600862 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:37:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.061889878 Vs 12:37:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.061899328 Vs 12:37:43 Magnet Current for MAIN, Imag = 160.0911 A Vtrans = 1.600863 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:37:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.061885455 Vs 12:37:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.061890082 Vs 12:37:57 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.061897598 +- 0.000009563 Vs 12:37:57 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.061897598 +- 0.000009563 Vs BL = -0.68775109 +- 0.00010626 Tm 12:38:01 Position moved: 0.000000 m 12:38:01 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.68775 0.00011 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.68775 0.00011 -0.68775 0.00000 12:38:01 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.68775 0.00011 SL = -0.6877511 +- 0.0001063 Tm^2/m^n 12:38:01 Magnet Strength Measurement Harmonic Number = 1 SL = -0.6877511 +- 0.0001063 Tm^2/m^n 12:38:04 Position moved: 0.000000 m 12:38:04 Magnet system MAIN current ramping to 140.0000 A... 12:38:21 Magnet Current for MAIN, Imag = 140.0826 A Vtrans = 1.400778 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:38:21 MAIN (V) Voltage Measurement, V = -21.495166 V 12:38:22 Temperature Measurement, Probe Number = 0, T = 25.806000 C 12:38:23 Temperature Measurement, Probe Number = 1, T = 30.202000 C 12:38:23 Temperature Measurement, Probe Number = 2, T = 17.423000 C 12:38:24 Sensor Voltage Measurement, Sensor Number = 0, V = 2.305759 V 12:38:24 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.305759 (V, A, ohm, ...), Measured Value = 28.135539 (C, atm, Hz, ...) 12:38:25 Sensor Voltage Measurement, Sensor Number = 1, V = 2.512954 V 12:38:25 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.512954 (V, A, ohm, ...), Measured Value = 31.013254 (C, atm, Hz, ...) 12:38:25 Sensor Voltage Measurement, Sensor Number = 2, V = 2.655427 V 12:38:25 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.655427 (V, A, ohm, ...), Measured Value = 124.157010 (C, atm, Hz, ...) 12:38:26 Sensor Voltage Measurement, Sensor Number = 3, V = 1.102436 V 12:38:26 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.102436 (V, A, ohm, ...), Measured Value = 7.682730 (C, atm, Hz, ...) 12:38:26 Magnet Test Parameter Measurements P0 = MAIN, Value = 140.08 P1 = MAIN (V), Value = -21.50 P2 = Magnet Core, Value = 25.81 P3 = Coil, Value = 30.20 P4 = Ambient Temp (C), Value = 17.42 P5 = Supply Temp(C), Value = 28.14 P6 = Return Temp(C), Value = 31.01 P7 = Supply Pres(psi), Value = 124.16 P8 = Return Pres(psi), Value = 7.68 12:38:26 Magnetic Field Measurement Measuring the magnet strength... 12:38:26 Integrated Voltage Measurement... 12:38:27 Magnet Current for MAIN, Imag = 140.0829 A Vtrans = 1.400781 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:38:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.054399291 Vs 12:38:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.054372178 Vs 12:38:43 Magnet Current for MAIN, Imag = 140.0832 A Vtrans = 1.400785 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:38:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.054371037 Vs 12:38:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.054358829 Vs 12:38:58 Magnet Current for MAIN, Imag = 140.0826 A Vtrans = 1.400778 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:39:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.054362210 Vs 12:39:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.054361138 Vs 12:39:12 Magnet Current for MAIN, Imag = 140.0831 A Vtrans = 1.400783 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:39:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.054354480 Vs 12:39:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.054361835 Vs 12:39:27 Magnet Current for MAIN, Imag = 140.0831 A Vtrans = 1.400783 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:39:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.054355294 Vs 12:39:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.054358799 Vs 12:39:41 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.054365509 +- 0.000010486 Vs 12:39:41 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.054365509 +- 0.000010486 Vs BL = -0.60406121 +- 0.00011651 Tm 12:39:45 Position moved: 0.000000 m 12:39:45 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.60406 0.00012 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.60406 0.00012 -0.60406 0.00000 12:39:45 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.60406 0.00012 SL = -0.6040612 +- 0.0001165 Tm^2/m^n 12:39:45 Magnet Strength Measurement Harmonic Number = 1 SL = -0.6040612 +- 0.0001165 Tm^2/m^n 12:39:48 Position moved: 0.000000 m 12:39:48 Magnet system MAIN current ramping to 120.0000 A... 12:40:05 Magnet Current for MAIN, Imag = 120.0345 A Vtrans = 1.200298 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:40:06 MAIN (V) Voltage Measurement, V = -18.358563 V 12:40:06 Temperature Measurement, Probe Number = 0, T = 25.824000 C 12:40:07 Temperature Measurement, Probe Number = 1, T = 29.829000 C 12:40:08 Temperature Measurement, Probe Number = 2, T = 17.447000 C 12:40:08 Sensor Voltage Measurement, Sensor Number = 0, V = 2.306139 V 12:40:08 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.306139 (V, A, ohm, ...), Measured Value = 28.140818 (C, atm, Hz, ...) 12:40:09 Sensor Voltage Measurement, Sensor Number = 1, V = 2.533664 V 12:40:09 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.533664 (V, A, ohm, ...), Measured Value = 31.300892 (C, atm, Hz, ...) 12:40:10 Sensor Voltage Measurement, Sensor Number = 2, V = 2.660779 V 12:40:10 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.660779 (V, A, ohm, ...), Measured Value = 124.558440 (C, atm, Hz, ...) 12:40:10 Sensor Voltage Measurement, Sensor Number = 3, V = 1.102560 V 12:40:10 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.102560 (V, A, ohm, ...), Measured Value = 7.691978 (C, atm, Hz, ...) 12:40:10 Magnet Test Parameter Measurements P0 = MAIN, Value = 120.03 P1 = MAIN (V), Value = -18.36 P2 = Magnet Core, Value = 25.82 P3 = Coil, Value = 29.83 P4 = Ambient Temp (C), Value = 17.45 P5 = Supply Temp(C), Value = 28.14 P6 = Return Temp(C), Value = 31.30 P7 = Supply Pres(psi), Value = 124.56 P8 = Return Pres(psi), Value = 7.69 12:40:10 Magnetic Field Measurement Measuring the magnet strength... 12:40:10 Integrated Voltage Measurement... 12:40:11 Magnet Current for MAIN, Imag = 120.0349 A Vtrans = 1.200301 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:40:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.046712248 Vs 12:40:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.046698192 Vs 12:40:27 Magnet Current for MAIN, Imag = 120.0349 A Vtrans = 1.200301 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:40:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.046695851 Vs 12:40:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.046692952 Vs 12:40:42 Magnet Current for MAIN, Imag = 120.0345 A Vtrans = 1.200298 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:40:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.046692054 Vs 12:40:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.046689876 Vs 12:40:57 Magnet Current for MAIN, Imag = 120.0343 A Vtrans = 1.200295 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:41:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.046683895 Vs 12:41:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.046688677 Vs 12:41:11 Magnet Current for MAIN, Imag = 120.0344 A Vtrans = 1.200296 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:41:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.046684739 Vs 12:41:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.046685574 Vs 12:41:25 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.046692406 +- 0.000007215 Vs 12:41:25 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.046692406 +- 0.000007215 Vs BL = -0.51880451 +- 0.00008017 Tm 12:41:29 Position moved: 0.000000 m 12:41:30 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.51880 0.00008 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.51880 0.00008 -0.51880 0.00000 12:41:30 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.51880 0.00008 SL = -0.5188045 +- 0.0000802 Tm^2/m^n 12:41:30 Magnet Strength Measurement Harmonic Number = 1 SL = -0.5188045 +- 0.0000802 Tm^2/m^n 12:41:33 Position moved: 0.000000 m 12:41:33 Magnet system MAIN current ramping to 100.0000 A... 12:41:49 Magnet Current for MAIN, Imag = 100.0471 A Vtrans = 1.000423 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:41:50 MAIN (V) Voltage Measurement, V = -15.253783 V 12:41:50 Temperature Measurement, Probe Number = 0, T = 25.836000 C 12:41:51 Temperature Measurement, Probe Number = 1, T = 29.441000 C 12:41:52 Temperature Measurement, Probe Number = 2, T = 17.458000 C 12:41:52 Sensor Voltage Measurement, Sensor Number = 0, V = 2.306322 V 12:41:52 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.306322 (V, A, ohm, ...), Measured Value = 28.143360 (C, atm, Hz, ...) 12:41:53 Sensor Voltage Measurement, Sensor Number = 1, V = 2.536675 V 12:41:53 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.536675 (V, A, ohm, ...), Measured Value = 31.342713 (C, atm, Hz, ...) 12:41:54 Sensor Voltage Measurement, Sensor Number = 2, V = 2.661692 V 12:41:54 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.661692 (V, A, ohm, ...), Measured Value = 124.626893 (C, atm, Hz, ...) 12:41:54 Sensor Voltage Measurement, Sensor Number = 3, V = 1.102790 V 12:41:54 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.102790 (V, A, ohm, ...), Measured Value = 7.709235 (C, atm, Hz, ...) 12:41:54 Magnet Test Parameter Measurements P0 = MAIN, Value = 100.05 P1 = MAIN (V), Value = -15.25 P2 = Magnet Core, Value = 25.84 P3 = Coil, Value = 29.44 P4 = Ambient Temp (C), Value = 17.46 P5 = Supply Temp(C), Value = 28.14 P6 = Return Temp(C), Value = 31.34 P7 = Supply Pres(psi), Value = 124.63 P8 = Return Pres(psi), Value = 7.71 12:41:55 Magnetic Field Measurement Measuring the magnet strength... 12:41:55 Integrated Voltage Measurement... 12:41:55 Magnet Current for MAIN, Imag = 100.0473 A Vtrans = 1.000425 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:42:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.038997069 Vs 12:42:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.038991984 Vs 12:42:11 Magnet Current for MAIN, Imag = 100.0475 A Vtrans = 1.000427 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:42:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.038984863 Vs 12:42:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.038985869 Vs 12:42:26 Magnet Current for MAIN, Imag = 100.0476 A Vtrans = 1.000428 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:42:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.038979524 Vs 12:42:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.038984452 Vs 12:42:41 Magnet Current for MAIN, Imag = 100.0474 A Vtrans = 1.000426 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:42:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.038971771 Vs 12:42:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.038982251 Vs 12:42:55 Magnet Current for MAIN, Imag = 100.0472 A Vtrans = 1.000424 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:43:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.038970700 Vs 12:43:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.038978763 Vs 12:43:09 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.038982725 +- 0.000006976 Vs 12:43:10 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.038982725 +- 0.000006976 Vs BL = -0.43314139 +- 0.00007751 Tm 12:43:13 Position moved: 0.000000 m 12:43:13 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.43314 0.00008 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.43314 0.00008 -0.43314 0.00000 12:43:14 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.43314 0.00008 SL = -0.4331414 +- 0.0000775 Tm^2/m^n 12:43:14 Magnet Strength Measurement Harmonic Number = 1 SL = -0.4331414 +- 0.0000775 Tm^2/m^n 12:43:16 Position moved: 0.000000 m 12:43:17 Magnet system MAIN current ramping to 80.0000 A... 12:43:33 Magnet Current for MAIN, Imag = 79.9982 A Vtrans = 0.799934 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:43:34 MAIN (V) Voltage Measurement, V = -12.163383 V 12:43:34 Temperature Measurement, Probe Number = 0, T = 25.847000 C 12:43:35 Temperature Measurement, Probe Number = 1, T = 28.933000 C 12:43:36 Temperature Measurement, Probe Number = 2, T = 17.448000 C 12:43:36 Sensor Voltage Measurement, Sensor Number = 0, V = 2.306445 V 12:43:36 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.306445 (V, A, ohm, ...), Measured Value = 28.145072 (C, atm, Hz, ...) 12:43:37 Sensor Voltage Measurement, Sensor Number = 1, V = 2.524735 V 12:43:37 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.524735 (V, A, ohm, ...), Measured Value = 31.176874 (C, atm, Hz, ...) 12:43:38 Sensor Voltage Measurement, Sensor Number = 2, V = 2.657058 V 12:43:38 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.657058 (V, A, ohm, ...), Measured Value = 124.279313 (C, atm, Hz, ...) 12:43:38 Sensor Voltage Measurement, Sensor Number = 3, V = 1.102736 V 12:43:38 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.102736 (V, A, ohm, ...), Measured Value = 7.705230 (C, atm, Hz, ...) 12:43:38 Magnet Test Parameter Measurements P0 = MAIN, Value = 80.00 P1 = MAIN (V), Value = -12.16 P2 = Magnet Core, Value = 25.85 P3 = Coil, Value = 28.93 P4 = Ambient Temp (C), Value = 17.45 P5 = Supply Temp(C), Value = 28.15 P6 = Return Temp(C), Value = 31.18 P7 = Supply Pres(psi), Value = 124.28 P8 = Return Pres(psi), Value = 7.71 12:43:39 Magnetic Field Measurement Measuring the magnet strength... 12:43:39 Integrated Voltage Measurement... 12:43:39 Magnet Current for MAIN, Imag = 79.9983 A Vtrans = 0.799935 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:43:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.031239388 Vs 12:43:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.031236927 Vs 12:43:55 Magnet Current for MAIN, Imag = 79.9981 A Vtrans = 0.799933 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:44:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.031226124 Vs 12:44:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.031229089 Vs 12:44:10 Magnet Current for MAIN, Imag = 79.9980 A Vtrans = 0.799932 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:44:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.031219982 Vs 12:44:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.031224237 Vs 12:44:25 Magnet Current for MAIN, Imag = 79.9981 A Vtrans = 0.799933 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:44:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.031215787 Vs 12:44:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.031221220 Vs 12:44:40 Magnet Current for MAIN, Imag = 79.9980 A Vtrans = 0.799932 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:44:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.031211702 Vs 12:44:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.031220237 Vs 12:44:54 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.031224469 +- 0.000007882 Vs 12:44:54 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.031224469 +- 0.000007882 Vs BL = -0.34693855 +- 0.00008758 Tm 12:44:58 Position moved: 0.000000 m 12:44:58 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.34694 0.00009 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.34694 0.00009 -0.34694 0.00000 12:44:58 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.34694 0.00009 SL = -0.3469385 +- 0.0000876 Tm^2/m^n 12:44:58 Magnet Strength Measurement Harmonic Number = 1 SL = -0.3469385 +- 0.0000876 Tm^2/m^n Remeasure 12:44:58 Magnetic Field Measurement Measuring the magnet strength... 12:44:58 Integrated Voltage Measurement... 12:44:59 Magnet Current for MAIN, Imag = 79.9979 A Vtrans = 0.799932 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:45:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.031211378 Vs 12:45:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.031216833 Vs 12:45:15 Magnet Current for MAIN, Imag = 79.9981 A Vtrans = 0.799933 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:45:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.031212382 Vs 12:45:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.031214818 Vs 12:45:30 Magnet Current for MAIN, Imag = 79.9978 A Vtrans = 0.799931 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:45:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.031208592 Vs 12:45:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.031217651 Vs 12:45:44 Magnet Current for MAIN, Imag = 79.9981 A Vtrans = 0.799933 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:45:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.031210174 Vs 12:45:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.031217479 Vs 12:45:59 Magnet Current for MAIN, Imag = 79.9979 A Vtrans = 0.799931 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:46:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.031210659 Vs 12:46:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.031218899 Vs 12:46:13 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.031213887 +- 0.000000551 Vs 12:46:13 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.031213887 +- 0.000000551 Vs BL = -0.34682096 +- 0.00000612 Tm 12:46:17 Position moved: 0.000000 m 12:46:17 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.34682 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.34682 0.00001 -0.34682 0.00000 12:46:17 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.34682 0.00001 SL = -0.3468210 +- 0.0000061 Tm^2/m^n 12:46:17 Magnet Strength Measurement Harmonic Number = 1 SL = -0.3468210 +- 0.0000061 Tm^2/m^n 12:46:20 Position moved: 0.000000 m 12:46:20 Magnet system MAIN current ramping to 60.0000 A... 12:46:37 Magnet Current for MAIN, Imag = 60.0092 A Vtrans = 0.600044 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:46:38 MAIN (V) Voltage Measurement, V = -9.095296 V 12:46:38 Temperature Measurement, Probe Number = 0, T = 25.829000 C 12:46:39 Temperature Measurement, Probe Number = 1, T = 28.097000 C 12:46:40 Temperature Measurement, Probe Number = 2, T = 17.482000 C 12:46:40 Sensor Voltage Measurement, Sensor Number = 0, V = 2.305904 V 12:46:40 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.305904 (V, A, ohm, ...), Measured Value = 28.137551 (C, atm, Hz, ...) 12:46:41 Sensor Voltage Measurement, Sensor Number = 1, V = 2.470722 V 12:46:41 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.470722 (V, A, ohm, ...), Measured Value = 30.426689 (C, atm, Hz, ...) 12:46:42 Sensor Voltage Measurement, Sensor Number = 2, V = 2.665382 V 12:46:42 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.665382 (V, A, ohm, ...), Measured Value = 124.903635 (C, atm, Hz, ...) 12:46:42 Sensor Voltage Measurement, Sensor Number = 3, V = 1.102664 V 12:46:42 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.102664 (V, A, ohm, ...), Measured Value = 7.699793 (C, atm, Hz, ...) 12:46:42 Magnet Test Parameter Measurements P0 = MAIN, Value = 60.01 P1 = MAIN (V), Value = -9.10 P2 = Magnet Core, Value = 25.83 P3 = Coil, Value = 28.10 P4 = Ambient Temp (C), Value = 17.48 P5 = Supply Temp(C), Value = 28.14 P6 = Return Temp(C), Value = 30.43 P7 = Supply Pres(psi), Value = 124.90 P8 = Return Pres(psi), Value = 7.70 12:46:42 Magnetic Field Measurement Measuring the magnet strength... 12:46:43 Integrated Voltage Measurement... 12:46:43 Magnet Current for MAIN, Imag = 60.0093 A Vtrans = 0.600045 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:46:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.023486871 Vs 12:46:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.023491707 Vs 12:46:59 Magnet Current for MAIN, Imag = 60.0097 A Vtrans = 0.600049 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:47:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.023470699 Vs 12:47:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.023478137 Vs 12:47:14 Magnet Current for MAIN, Imag = 60.0096 A Vtrans = 0.600048 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:47:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.023464503 Vs 12:47:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.023472264 Vs 12:47:29 Magnet Current for MAIN, Imag = 60.0095 A Vtrans = 0.600047 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:47:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.023463081 Vs 12:47:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.023470639 Vs 12:47:43 Magnet Current for MAIN, Imag = 60.0092 A Vtrans = 0.600044 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:47:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.023460647 Vs 12:47:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.023466664 Vs 12:47:57 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.023472521 +- 0.000009083 Vs 12:47:58 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.023472521 +- 0.000009083 Vs BL = -0.26080579 +- 0.00010092 Tm 12:48:01 Position moved: 0.000000 m 12:48:01 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.26081 0.00010 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.26081 0.00010 -0.26081 0.00000 12:48:02 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.26081 0.00010 SL = -0.2608058 +- 0.0001009 Tm^2/m^n 12:48:02 Magnet Strength Measurement Harmonic Number = 1 SL = -0.2608058 +- 0.0001009 Tm^2/m^n Remeasure 12:48:02 Magnetic Field Measurement Measuring the magnet strength... 12:48:02 Integrated Voltage Measurement... 12:48:02 Magnet Current for MAIN, Imag = 60.0094 A Vtrans = 0.600047 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:48:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.023457274 Vs 12:48:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.023466404 Vs 12:48:18 Magnet Current for MAIN, Imag = 60.0091 A Vtrans = 0.600043 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:48:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.023456871 Vs 12:48:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.023464172 Vs 12:48:33 Magnet Current for MAIN, Imag = 60.0095 A Vtrans = 0.600047 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:48:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.023457746 Vs 12:48:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.023467226 Vs 12:48:48 Magnet Current for MAIN, Imag = 60.0094 A Vtrans = 0.600046 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:48:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.023455703 Vs 12:49:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.023465926 Vs 12:49:03 Magnet Current for MAIN, Imag = 60.0091 A Vtrans = 0.600043 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:49:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.023455667 Vs 12:49:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.023464545 Vs 12:49:17 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.023461153 +- 0.000000878 Vs 12:49:17 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.023461153 +- 0.000000878 Vs BL = -0.26067948 +- 0.00000976 Tm 12:49:21 Position moved: 0.000000 m 12:49:21 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.26068 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.26068 0.00001 -0.26068 0.00000 12:49:21 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.26068 0.00001 SL = -0.2606795 +- 0.0000098 Tm^2/m^n 12:49:21 Magnet Strength Measurement Harmonic Number = 1 SL = -0.2606795 +- 0.0000098 Tm^2/m^n 12:49:24 Position moved: 0.000000 m 12:49:24 Magnet system MAIN current ramping to 40.0000 A... 12:49:40 Magnet Current for MAIN, Imag = 39.9585 A Vtrans = 0.399537 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:49:41 MAIN (V) Voltage Measurement, V = -6.044341 V 12:49:42 Temperature Measurement, Probe Number = 0, T = 25.805000 C 12:49:42 Temperature Measurement, Probe Number = 1, T = 27.516000 C 12:49:43 Temperature Measurement, Probe Number = 2, T = 17.530000 C 12:49:44 Sensor Voltage Measurement, Sensor Number = 0, V = 2.306045 V 12:49:44 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.306045 (V, A, ohm, ...), Measured Value = 28.139511 (C, atm, Hz, ...) 12:49:44 Sensor Voltage Measurement, Sensor Number = 1, V = 2.409660 V 12:49:44 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.409660 (V, A, ohm, ...), Measured Value = 29.578615 (C, atm, Hz, ...) 12:49:45 Sensor Voltage Measurement, Sensor Number = 2, V = 2.659326 V 12:49:45 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.659326 (V, A, ohm, ...), Measured Value = 124.449480 (C, atm, Hz, ...) 12:49:46 Sensor Voltage Measurement, Sensor Number = 3, V = 1.102374 V 12:49:46 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.102374 (V, A, ohm, ...), Measured Value = 7.678058 (C, atm, Hz, ...) 12:49:46 Magnet Test Parameter Measurements P0 = MAIN, Value = 39.96 P1 = MAIN (V), Value = -6.04 P2 = Magnet Core, Value = 25.80 P3 = Coil, Value = 27.52 P4 = Ambient Temp (C), Value = 17.53 P5 = Supply Temp(C), Value = 28.14 P6 = Return Temp(C), Value = 29.58 P7 = Supply Pres(psi), Value = 124.45 P8 = Return Pres(psi), Value = 7.68 12:49:46 Magnetic Field Measurement Measuring the magnet strength... 12:49:46 Integrated Voltage Measurement... 12:49:47 Magnet Current for MAIN, Imag = 39.9584 A Vtrans = 0.399537 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:49:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.015703796 Vs 12:50:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.015710074 Vs 12:50:02 Magnet Current for MAIN, Imag = 39.9586 A Vtrans = 0.399538 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:50:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.015687160 Vs 12:50:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.015697298 Vs 12:50:17 Magnet Current for MAIN, Imag = 39.9585 A Vtrans = 0.399537 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:50:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.015682445 Vs 12:50:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.015688608 Vs 12:50:32 Magnet Current for MAIN, Imag = 39.9582 A Vtrans = 0.399535 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:50:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.015677068 Vs 12:50:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.015684360 Vs 12:50:47 Magnet Current for MAIN, Imag = 39.9584 A Vtrans = 0.399536 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:50:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.015675689 Vs 12:51:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.015683342 Vs 12:51:01 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.015688984 +- 0.000010028 Vs 12:51:01 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.015688984 +- 0.000010028 Vs BL = -0.17432205 +- 0.00011142 Tm 12:51:05 Position moved: 0.000000 m 12:51:05 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.17432 0.00011 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.17432 0.00011 -0.17432 0.00000 12:51:05 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.17432 0.00011 SL = -0.1743220 +- 0.0001114 Tm^2/m^n 12:51:05 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1743220 +- 0.0001114 Tm^2/m^n Remeasure 12:51:05 Magnetic Field Measurement Measuring the magnet strength... 12:51:05 Integrated Voltage Measurement... 12:51:06 Magnet Current for MAIN, Imag = 39.9582 A Vtrans = 0.399534 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:51:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.015675649 Vs 12:51:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.015680882 Vs 12:51:22 Magnet Current for MAIN, Imag = 39.9582 A Vtrans = 0.399534 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:51:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.015674445 Vs 12:51:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.015680890 Vs 12:51:36 Magnet Current for MAIN, Imag = 39.9581 A Vtrans = 0.399533 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:51:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.015674859 Vs 12:51:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.015679012 Vs 12:51:51 Magnet Current for MAIN, Imag = 39.9586 A Vtrans = 0.399538 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:51:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.015675324 Vs 12:52:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.015677660 Vs 12:52:06 Magnet Current for MAIN, Imag = 39.9584 A Vtrans = 0.399536 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:52:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.015673727 Vs 12:52:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.015677595 Vs 12:52:20 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.015677004 +- 0.000000906 Vs 12:52:20 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.015677004 +- 0.000000906 Vs BL = -0.17418894 +- 0.00001006 Tm 12:52:24 Position moved: 0.000000 m 12:52:24 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.17419 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.17419 0.00001 -0.17419 0.00000 12:52:24 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.17419 0.00001 SL = -0.1741889 +- 0.0000101 Tm^2/m^n 12:52:24 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1741889 +- 0.0000101 Tm^2/m^n 12:52:27 Position moved: 0.000000 m 12:52:27 Magnet system MAIN current ramping to 20.0000 A... 12:52:44 Magnet Current for MAIN, Imag = 19.9747 A Vtrans = 0.199699 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:52:44 MAIN (V) Voltage Measurement, V = -3.016318 V 12:52:45 Temperature Measurement, Probe Number = 0, T = 25.761000 C 12:52:45 Temperature Measurement, Probe Number = 1, T = 27.190000 C 12:52:46 Temperature Measurement, Probe Number = 2, T = 17.538000 C 12:52:47 Sensor Voltage Measurement, Sensor Number = 0, V = 2.305430 V 12:52:47 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.305430 (V, A, ohm, ...), Measured Value = 28.130967 (C, atm, Hz, ...) 12:52:47 Sensor Voltage Measurement, Sensor Number = 1, V = 2.358182 V 12:52:47 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.358182 (V, A, ohm, ...), Measured Value = 28.863636 (C, atm, Hz, ...) 12:52:48 Sensor Voltage Measurement, Sensor Number = 2, V = 2.657735 V 12:52:48 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.657735 (V, A, ohm, ...), Measured Value = 124.330125 (C, atm, Hz, ...) 12:52:49 Sensor Voltage Measurement, Sensor Number = 3, V = 1.102097 V 12:52:49 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.102097 (V, A, ohm, ...), Measured Value = 7.657275 (C, atm, Hz, ...) 12:52:49 Magnet Test Parameter Measurements P0 = MAIN, Value = 19.97 P1 = MAIN (V), Value = -3.02 P2 = Magnet Core, Value = 25.76 P3 = Coil, Value = 27.19 P4 = Ambient Temp (C), Value = 17.54 P5 = Supply Temp(C), Value = 28.13 P6 = Return Temp(C), Value = 28.86 P7 = Supply Pres(psi), Value = 124.33 P8 = Return Pres(psi), Value = 7.66 12:52:49 Magnetic Field Measurement Measuring the magnet strength... 12:52:49 Integrated Voltage Measurement... 12:52:50 Magnet Current for MAIN, Imag = 19.9745 A Vtrans = 0.199697 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:52:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.007938828 Vs 12:53:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.007947252 Vs 12:53:06 Magnet Current for MAIN, Imag = 19.9748 A Vtrans = 0.199700 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:53:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.007922266 Vs 12:53:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.007931946 Vs 12:53:20 Magnet Current for MAIN, Imag = 19.9749 A Vtrans = 0.199701 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:53:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.007916562 Vs 12:53:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.007923923 Vs 12:53:35 Magnet Current for MAIN, Imag = 19.9751 A Vtrans = 0.199703 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:53:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.007912032 Vs 12:53:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.007919181 Vs 12:53:50 Magnet Current for MAIN, Imag = 19.9750 A Vtrans = 0.199702 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:53:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.007910625 Vs 12:54:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.007917105 Vs 12:54:04 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.007923972 +- 0.000010578 Vs 12:54:04 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.007923972 +- 0.000010578 Vs BL = -0.08804413 +- 0.00011753 Tm 12:54:08 Position moved: 0.000000 m 12:54:08 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.08804 0.00012 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.08804 0.00012 -0.08804 0.00000 12:54:08 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.08804 0.00012 SL = -0.0880441 +- 0.0001175 Tm^2/m^n 12:54:08 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0880441 +- 0.0001175 Tm^2/m^n Remeasure 12:54:08 Magnetic Field Measurement Measuring the magnet strength... 12:54:08 Integrated Voltage Measurement... 12:54:09 Magnet Current for MAIN, Imag = 19.9751 A Vtrans = 0.199704 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:54:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.007908655 Vs 12:54:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.007915570 Vs 12:54:25 Magnet Current for MAIN, Imag = 19.9752 A Vtrans = 0.199704 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:54:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.007907865 Vs 12:54:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.007914510 Vs 12:54:40 Magnet Current for MAIN, Imag = 19.9752 A Vtrans = 0.199704 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:54:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.007908011 Vs 12:54:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.007913247 Vs 12:54:54 Magnet Current for MAIN, Imag = 19.9753 A Vtrans = 0.199706 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:55:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.007907186 Vs 12:55:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.007912348 Vs 12:55:09 Magnet Current for MAIN, Imag = 19.9754 A Vtrans = 0.199706 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:55:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.007906219 Vs 12:55:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.007913072 Vs 12:55:23 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.007910668 +- 0.000000918 Vs 12:55:23 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.007910668 +- 0.000000918 Vs BL = -0.08789631 +- 0.00001020 Tm 12:55:27 Position moved: 0.000000 m 12:55:27 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.08790 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.08790 0.00001 -0.08790 0.00000 12:55:27 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.08790 0.00001 SL = -0.0878963 +- 0.0000102 Tm^2/m^n 12:55:27 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0878963 +- 0.0000102 Tm^2/m^n 12:55:30 Position moved: 0.000000 m 12:55:30 Magnet system MAIN current ramping to 0.0000 A... 12:55:47 Magnet Current for MAIN, Imag = 0.0019 A Vtrans = -0.000029 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:55:48 MAIN (V) Voltage Measurement, V = 0.003004 V 12:55:48 Temperature Measurement, Probe Number = 0, T = 25.671000 C 12:55:49 Temperature Measurement, Probe Number = 1, T = 26.584000 C 12:55:50 Temperature Measurement, Probe Number = 2, T = 17.028000 C 12:55:50 Sensor Voltage Measurement, Sensor Number = 0, V = 2.301974 V 12:55:51 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.301974 (V, A, ohm, ...), Measured Value = 28.082967 (C, atm, Hz, ...) 12:55:51 Sensor Voltage Measurement, Sensor Number = 1, V = 2.313561 V 12:55:51 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.313561 (V, A, ohm, ...), Measured Value = 28.243900 (C, atm, Hz, ...) 12:55:52 Sensor Voltage Measurement, Sensor Number = 2, V = 2.653533 V 12:55:52 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.653533 (V, A, ohm, ...), Measured Value = 124.014968 (C, atm, Hz, ...) 12:55:53 Sensor Voltage Measurement, Sensor Number = 3, V = 1.102173 V 12:55:53 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.102173 (V, A, ohm, ...), Measured Value = 7.662998 (C, atm, Hz, ...) 12:55:53 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = MAIN (V), Value = 0.00 P2 = Magnet Core, Value = 25.67 P3 = Coil, Value = 26.58 P4 = Ambient Temp (C), Value = 17.03 P5 = Supply Temp(C), Value = 28.08 P6 = Return Temp(C), Value = 28.24 P7 = Supply Pres(psi), Value = 124.01 P8 = Return Pres(psi), Value = 7.66 12:55:53 Magnetic Field Measurement Measuring the magnet strength... 12:55:53 Integrated Voltage Measurement... 12:55:53 Magnet Current for MAIN, Imag = 0.0014 A Vtrans = -0.000033 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:56:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.000165543 Vs 12:56:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.000180708 Vs 12:56:09 Magnet Current for MAIN, Imag = 0.0009 A Vtrans = -0.000039 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:56:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.000147804 Vs 12:56:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.000161970 Vs 12:56:24 Magnet Current for MAIN, Imag = 0.0006 A Vtrans = -0.000041 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:56:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.000140070 Vs 12:56:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.000152995 Vs 12:56:39 Magnet Current for MAIN, Imag = 0.0005 A Vtrans = -0.000043 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:56:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.000136013 Vs 12:56:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.000148111 Vs 12:56:54 Magnet Current for MAIN, Imag = 0.0003 A Vtrans = -0.000045 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:57:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.000132431 Vs 12:57:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.000145317 Vs 12:57:08 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.000151096 +- 0.000012260 Vs 12:57:08 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.000151096 +- 0.000012260 Vs BL = -0.00167885 +- 0.00013622 Tm 12:57:12 Position moved: 0.000000 m 12:57:12 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00168 0.00014 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.00168 0.00014 -0.00168 0.00000 12:57:12 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00168 0.00014 SL = -0.0016788 +- 0.0001362 Tm^2/m^n 12:57:12 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0016788 +- 0.0001362 Tm^2/m^n 12:57:15 Position moved: 0.000000 m 12:57:15 Magnet system MAIN current ramping to 200.0000 A... 12:58:22 Magnet Current for MAIN, Imag = 200.1218 A Vtrans = 2.001170 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:58:22 MAIN (V) Voltage Measurement, V = -30.448139 V 12:58:23 Temperature Measurement, Probe Number = 0, T = 25.626000 C 12:58:24 Temperature Measurement, Probe Number = 1, T = 26.336000 C 12:58:24 Temperature Measurement, Probe Number = 2, T = 16.733000 C 12:58:25 Sensor Voltage Measurement, Sensor Number = 0, V = 2.302458 V 12:58:25 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.302458 (V, A, ohm, ...), Measured Value = 28.089692 (C, atm, Hz, ...) 12:58:26 Sensor Voltage Measurement, Sensor Number = 1, V = 2.283582 V 12:58:26 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.283582 (V, A, ohm, ...), Measured Value = 27.827533 (C, atm, Hz, ...) 12:58:26 Sensor Voltage Measurement, Sensor Number = 2, V = 2.662040 V 12:58:26 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.662040 (V, A, ohm, ...), Measured Value = 124.653008 (C, atm, Hz, ...) 12:58:27 Sensor Voltage Measurement, Sensor Number = 3, V = 1.101805 V 12:58:27 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.101805 (V, A, ohm, ...), Measured Value = 7.635352 (C, atm, Hz, ...) 12:58:27 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.12 P1 = MAIN (V), Value = -30.45 P2 = Magnet Core, Value = 25.63 P3 = Coil, Value = 26.34 P4 = Ambient Temp (C), Value = 16.73 P5 = Supply Temp(C), Value = 28.09 P6 = Return Temp(C), Value = 27.83 P7 = Supply Pres(psi), Value = 124.65 P8 = Return Pres(psi), Value = 7.64 12:58:27 Integrated Voltage Measurement... 12:58:28 Magnet Current for MAIN, Imag = 200.1219 A Vtrans = 2.001171 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:58:37 Integrated Voltage Measurement X0 = -0.0450000 m, Delta X = 0.0030000 m VT = -0.025132367 Vs 12:58:44 Integrated Voltage Measurement X0 = -0.0450000 m, Delta X = -0.0030000 m VT = 0.025144491 Vs 12:58:45 Magnet Current for MAIN, Imag = 200.1218 A Vtrans = 2.001170 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:58:52 Integrated Voltage Measurement X0 = -0.0450000 m, Delta X = 0.0030000 m VT = -0.025137195 Vs 12:58:59 Integrated Voltage Measurement X0 = -0.0450000 m, Delta X = -0.0030000 m VT = 0.025140121 Vs 12:59:00 Magnet Current for MAIN, Imag = 200.1214 A Vtrans = 2.001166 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:59:07 Integrated Voltage Measurement X0 = -0.0450000 m, Delta X = 0.0030000 m VT = -0.025140713 Vs 12:59:14 Integrated Voltage Measurement X0 = -0.0450000 m, Delta X = -0.0030000 m VT = 0.025143680 Vs 12:59:14 Magnet Current for MAIN, Imag = 200.1216 A Vtrans = 2.001168 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:59:21 Integrated Voltage Measurement X0 = -0.0450000 m, Delta X = 0.0030000 m VT = -0.025142631 Vs 12:59:28 Integrated Voltage Measurement X0 = -0.0450000 m, Delta X = -0.0030000 m VT = 0.025142697 Vs 12:59:29 Magnet Current for MAIN, Imag = 200.1216 A Vtrans = 2.001168 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:59:36 Integrated Voltage Measurement X0 = -0.0450000 m, Delta X = 0.0030000 m VT = -0.025133767 Vs 12:59:43 Integrated Voltage Measurement X0 = -0.0450000 m, Delta X = -0.0030000 m VT = 0.025140276 Vs 12:59:43 Integrated Voltage Average and RMS of Measurements X0 = -0.0450000 m, Delta X = 0.0030000 m VT = -0.025139794 +- 0.000002229 Vs 12:59:43 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0450000 m, dx = 0.0030000 m, Nturns = 10.0 VT = -0.025139794 +- 0.000002229 Vs BL = -0.83799313 +- 0.00007431 Tm 12:59:43 Integrated Voltage Measurement... 12:59:44 Magnet Current for MAIN, Imag = 200.1215 A Vtrans = 2.001167 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 12:59:52 Integrated Voltage Measurement X0 = -0.0420000 m, Delta X = 0.0030000 m VT = -0.025117565 Vs 12:59:59 Integrated Voltage Measurement X0 = -0.0420000 m, Delta X = -0.0030000 m VT = 0.025123782 Vs 13:00:00 Magnet Current for MAIN, Imag = 200.1224 A Vtrans = 2.001176 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:00:07 Integrated Voltage Measurement X0 = -0.0420000 m, Delta X = 0.0030000 m VT = -0.025119862 Vs 13:00:14 Integrated Voltage Measurement X0 = -0.0420000 m, Delta X = -0.0030000 m VT = 0.025117722 Vs 13:00:15 Magnet Current for MAIN, Imag = 200.1221 A Vtrans = 2.001174 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:00:22 Integrated Voltage Measurement X0 = -0.0420000 m, Delta X = 0.0030000 m VT = -0.025117750 Vs 13:00:29 Integrated Voltage Measurement X0 = -0.0420000 m, Delta X = -0.0030000 m VT = 0.025118646 Vs 13:00:29 Magnet Current for MAIN, Imag = 200.1221 A Vtrans = 2.001174 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:00:36 Integrated Voltage Measurement X0 = -0.0420000 m, Delta X = 0.0030000 m VT = -0.025117772 Vs 13:00:43 Integrated Voltage Measurement X0 = -0.0420000 m, Delta X = -0.0030000 m VT = 0.025119547 Vs 13:00:44 Magnet Current for MAIN, Imag = 200.1221 A Vtrans = 2.001174 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:00:51 Integrated Voltage Measurement X0 = -0.0420000 m, Delta X = 0.0030000 m VT = -0.025117138 Vs 13:00:58 Integrated Voltage Measurement X0 = -0.0420000 m, Delta X = -0.0030000 m VT = 0.025117361 Vs 13:00:58 Integrated Voltage Average and RMS of Measurements X0 = -0.0420000 m, Delta X = 0.0030000 m VT = -0.025118714 +- 0.000001119 Vs 13:00:58 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0420000 m, dx = 0.0030000 m, Nturns = 10.0 VT = -0.025118714 +- 0.000001119 Vs BL = -0.83729048 +- 0.00003729 Tm 13:00:58 Integrated Voltage Measurement... 13:00:59 Magnet Current for MAIN, Imag = 200.1225 A Vtrans = 2.001177 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:01:07 Integrated Voltage Measurement X0 = -0.0390000 m, Delta X = 0.0030000 m VT = -0.025123110 Vs 13:01:14 Integrated Voltage Measurement X0 = -0.0390000 m, Delta X = -0.0030000 m VT = 0.025119781 Vs 13:01:15 Magnet Current for MAIN, Imag = 200.1223 A Vtrans = 2.001175 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:01:22 Integrated Voltage Measurement X0 = -0.0390000 m, Delta X = 0.0030000 m VT = -0.025110630 Vs 13:01:29 Integrated Voltage Measurement X0 = -0.0390000 m, Delta X = -0.0030000 m VT = 0.025113723 Vs 13:01:29 Magnet Current for MAIN, Imag = 200.1220 A Vtrans = 2.001172 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:01:36 Integrated Voltage Measurement X0 = -0.0390000 m, Delta X = 0.0030000 m VT = -0.025112900 Vs 13:01:43 Integrated Voltage Measurement X0 = -0.0390000 m, Delta X = -0.0030000 m VT = 0.025115498 Vs 13:01:44 Magnet Current for MAIN, Imag = 200.1221 A Vtrans = 2.001174 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:01:51 Integrated Voltage Measurement X0 = -0.0390000 m, Delta X = 0.0030000 m VT = -0.025118082 Vs 13:01:58 Integrated Voltage Measurement X0 = -0.0390000 m, Delta X = -0.0030000 m VT = 0.025110065 Vs 13:01:59 Magnet Current for MAIN, Imag = 200.1226 A Vtrans = 2.001179 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:02:06 Integrated Voltage Measurement X0 = -0.0390000 m, Delta X = 0.0030000 m VT = -0.025107988 Vs 13:02:13 Integrated Voltage Measurement X0 = -0.0390000 m, Delta X = -0.0030000 m VT = 0.025116822 Vs 13:02:13 Integrated Voltage Average and RMS of Measurements X0 = -0.0390000 m, Delta X = 0.0030000 m VT = -0.025114860 +- 0.000003396 Vs 13:02:13 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0390000 m, dx = 0.0030000 m, Nturns = 10.0 VT = -0.025114860 +- 0.000003396 Vs BL = -0.83716200 +- 0.00011319 Tm 13:02:13 Integrated Voltage Measurement... 13:02:14 Magnet Current for MAIN, Imag = 200.1221 A Vtrans = 2.001174 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:02:22 Integrated Voltage Measurement X0 = -0.0360000 m, Delta X = 0.0030000 m VT = -0.025116888 Vs 13:02:29 Integrated Voltage Measurement X0 = -0.0360000 m, Delta X = -0.0030000 m VT = 0.025120477 Vs 13:02:30 Magnet Current for MAIN, Imag = 200.1220 A Vtrans = 2.001172 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:02:37 Integrated Voltage Measurement X0 = -0.0360000 m, Delta X = 0.0030000 m VT = -0.025113142 Vs 13:02:44 Integrated Voltage Measurement X0 = -0.0360000 m, Delta X = -0.0030000 m VT = 0.025114645 Vs 13:02:45 Magnet Current for MAIN, Imag = 200.1216 A Vtrans = 2.001168 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:02:52 Integrated Voltage Measurement X0 = -0.0360000 m, Delta X = 0.0030000 m VT = -0.025113282 Vs 13:02:59 Integrated Voltage Measurement X0 = -0.0360000 m, Delta X = -0.0030000 m VT = 0.025115351 Vs 13:02:59 Magnet Current for MAIN, Imag = 200.1224 A Vtrans = 2.001176 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:03:06 Integrated Voltage Measurement X0 = -0.0360000 m, Delta X = 0.0030000 m VT = -0.025114417 Vs 13:03:13 Integrated Voltage Measurement X0 = -0.0360000 m, Delta X = -0.0030000 m VT = 0.025119904 Vs 13:03:14 Magnet Current for MAIN, Imag = 200.1219 A Vtrans = 2.001171 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:03:21 Integrated Voltage Measurement X0 = -0.0360000 m, Delta X = 0.0030000 m VT = -0.025112907 Vs 13:03:28 Integrated Voltage Measurement X0 = -0.0360000 m, Delta X = -0.0030000 m VT = 0.025118158 Vs 13:03:28 Integrated Voltage Average and RMS of Measurements X0 = -0.0360000 m, Delta X = 0.0030000 m VT = -0.025115917 +- 0.000001789 Vs 13:03:28 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0360000 m, dx = 0.0030000 m, Nturns = 10.0 VT = -0.025115917 +- 0.000001789 Vs BL = -0.83719723 +- 0.00005963 Tm 13:03:28 Integrated Voltage Measurement... 13:03:29 Magnet Current for MAIN, Imag = 200.1221 A Vtrans = 2.001174 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:03:37 Integrated Voltage Measurement X0 = -0.0330000 m, Delta X = 0.0030000 m VT = -0.025115630 Vs 13:03:44 Integrated Voltage Measurement X0 = -0.0330000 m, Delta X = -0.0030000 m VT = 0.025123810 Vs 13:03:45 Magnet Current for MAIN, Imag = 200.1221 A Vtrans = 2.001174 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:03:52 Integrated Voltage Measurement X0 = -0.0330000 m, Delta X = 0.0030000 m VT = -0.025112695 Vs 13:03:59 Integrated Voltage Measurement X0 = -0.0330000 m, Delta X = -0.0030000 m VT = 0.025120191 Vs 13:04:00 Magnet Current for MAIN, Imag = 200.1220 A Vtrans = 2.001172 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:04:07 Integrated Voltage Measurement X0 = -0.0330000 m, Delta X = 0.0030000 m VT = -0.025117847 Vs 13:04:14 Integrated Voltage Measurement X0 = -0.0330000 m, Delta X = -0.0030000 m VT = 0.025121572 Vs 13:04:14 Magnet Current for MAIN, Imag = 200.1221 A Vtrans = 2.001174 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:04:21 Integrated Voltage Measurement X0 = -0.0330000 m, Delta X = 0.0030000 m VT = -0.025117837 Vs 13:04:28 Integrated Voltage Measurement X0 = -0.0330000 m, Delta X = -0.0030000 m VT = 0.025122120 Vs 13:04:29 Magnet Current for MAIN, Imag = 200.1225 A Vtrans = 2.001177 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:04:36 Integrated Voltage Measurement X0 = -0.0330000 m, Delta X = 0.0030000 m VT = -0.025115495 Vs 13:04:43 Integrated Voltage Measurement X0 = -0.0330000 m, Delta X = -0.0030000 m VT = 0.025123646 Vs 13:04:43 Integrated Voltage Average and RMS of Measurements X0 = -0.0330000 m, Delta X = 0.0030000 m VT = -0.025119084 +- 0.000001327 Vs 13:04:43 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0330000 m, dx = 0.0030000 m, Nturns = 10.0 VT = -0.025119084 +- 0.000001327 Vs BL = -0.83730281 +- 0.00004424 Tm 13:04:43 Integrated Voltage Measurement... 13:04:44 Magnet Current for MAIN, Imag = 200.1224 A Vtrans = 2.001176 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:04:52 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0030000 m VT = -0.025125656 Vs 13:04:59 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0030000 m VT = 0.025126137 Vs 13:05:00 Magnet Current for MAIN, Imag = 200.1223 A Vtrans = 2.001175 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:05:07 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0030000 m VT = -0.025117834 Vs 13:05:14 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0030000 m VT = 0.025126857 Vs 13:05:14 Magnet Current for MAIN, Imag = 200.1220 A Vtrans = 2.001172 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:05:21 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0030000 m VT = -0.025117644 Vs 13:05:29 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0030000 m VT = 0.025125704 Vs 13:05:29 Magnet Current for MAIN, Imag = 200.1218 A Vtrans = 2.001170 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:05:36 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0030000 m VT = -0.025117967 Vs 13:05:43 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0030000 m VT = 0.025124565 Vs 13:05:44 Magnet Current for MAIN, Imag = 200.1220 A Vtrans = 2.001172 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:05:51 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0030000 m VT = -0.025119615 Vs 13:05:58 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0030000 m VT = 0.025122937 Vs 13:05:58 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0030000 m VT = -0.025122492 +- 0.000001747 Vs 13:05:58 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0030000 m, Nturns = 10.0 VT = -0.025122492 +- 0.000001747 Vs BL = -0.83741639 +- 0.00005824 Tm 13:05:58 Integrated Voltage Measurement... 13:05:59 Magnet Current for MAIN, Imag = 200.1220 A Vtrans = 2.001172 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:06:07 Integrated Voltage Measurement X0 = -0.0270000 m, Delta X = 0.0030000 m VT = -0.025133365 Vs 13:06:14 Integrated Voltage Measurement X0 = -0.0270000 m, Delta X = -0.0030000 m VT = 0.025135159 Vs 13:06:15 Magnet Current for MAIN, Imag = 200.1220 A Vtrans = 2.001172 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:06:22 Integrated Voltage Measurement X0 = -0.0270000 m, Delta X = 0.0030000 m VT = -0.025132232 Vs 13:06:29 Integrated Voltage Measurement X0 = -0.0270000 m, Delta X = -0.0030000 m VT = 0.025132964 Vs 13:06:29 Magnet Current for MAIN, Imag = 200.1219 A Vtrans = 2.001171 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:06:36 Integrated Voltage Measurement X0 = -0.0270000 m, Delta X = 0.0030000 m VT = -0.025133886 Vs 13:06:43 Integrated Voltage Measurement X0 = -0.0270000 m, Delta X = -0.0030000 m VT = 0.025133368 Vs 13:06:44 Magnet Current for MAIN, Imag = 200.1223 A Vtrans = 2.001175 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:06:51 Integrated Voltage Measurement X0 = -0.0270000 m, Delta X = 0.0030000 m VT = -0.025125507 Vs 13:06:58 Integrated Voltage Measurement X0 = -0.0270000 m, Delta X = -0.0030000 m VT = 0.025132369 Vs 13:06:59 Magnet Current for MAIN, Imag = 200.1219 A Vtrans = 2.001171 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:07:06 Integrated Voltage Measurement X0 = -0.0270000 m, Delta X = 0.0030000 m VT = -0.025132734 Vs 13:07:13 Integrated Voltage Measurement X0 = -0.0270000 m, Delta X = -0.0030000 m VT = 0.025130580 Vs 13:07:13 Integrated Voltage Average and RMS of Measurements X0 = -0.0270000 m, Delta X = 0.0030000 m VT = -0.025132216 +- 0.000001865 Vs 13:07:13 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0270000 m, dx = 0.0030000 m, Nturns = 10.0 VT = -0.025132216 +- 0.000001865 Vs BL = -0.83774055 +- 0.00006215 Tm 13:07:13 Integrated Voltage Measurement... 13:07:14 Magnet Current for MAIN, Imag = 200.1220 A Vtrans = 2.001172 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:07:22 Integrated Voltage Measurement X0 = -0.0240000 m, Delta X = 0.0030000 m VT = -0.025127911 Vs 13:07:29 Integrated Voltage Measurement X0 = -0.0240000 m, Delta X = -0.0030000 m VT = 0.025137976 Vs 13:07:29 Magnet Current for MAIN, Imag = 200.1219 A Vtrans = 2.001171 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:07:36 Integrated Voltage Measurement X0 = -0.0240000 m, Delta X = 0.0030000 m VT = -0.025130260 Vs 13:07:43 Integrated Voltage Measurement X0 = -0.0240000 m, Delta X = -0.0030000 m VT = 0.025137327 Vs 13:07:44 Magnet Current for MAIN, Imag = 200.1221 A Vtrans = 2.001174 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:07:51 Integrated Voltage Measurement X0 = -0.0240000 m, Delta X = 0.0030000 m VT = -0.025126083 Vs 13:07:58 Integrated Voltage Measurement X0 = -0.0240000 m, Delta X = -0.0030000 m VT = 0.025135789 Vs 13:07:59 Magnet Current for MAIN, Imag = 200.1220 A Vtrans = 2.001172 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:08:06 Integrated Voltage Measurement X0 = -0.0240000 m, Delta X = 0.0030000 m VT = -0.025131084 Vs 13:08:13 Integrated Voltage Measurement X0 = -0.0240000 m, Delta X = -0.0030000 m VT = 0.025137318 Vs 13:08:14 Magnet Current for MAIN, Imag = 200.1223 A Vtrans = 2.001175 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:08:21 Integrated Voltage Measurement X0 = -0.0240000 m, Delta X = 0.0030000 m VT = -0.025128153 Vs 13:08:28 Integrated Voltage Measurement X0 = -0.0240000 m, Delta X = -0.0030000 m VT = 0.025136886 Vs 13:08:28 Integrated Voltage Average and RMS of Measurements X0 = -0.0240000 m, Delta X = 0.0030000 m VT = -0.025132879 +- 0.000001140 Vs 13:08:28 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0240000 m, dx = 0.0030000 m, Nturns = 10.0 VT = -0.025132879 +- 0.000001140 Vs BL = -0.83776262 +- 0.00003798 Tm 13:08:28 Integrated Voltage Measurement... 13:08:28 Magnet Current for MAIN, Imag = 200.1219 A Vtrans = 2.001171 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:08:36 Integrated Voltage Measurement X0 = -0.0210000 m, Delta X = 0.0030000 m VT = -0.025142724 Vs 13:08:43 Integrated Voltage Measurement X0 = -0.0210000 m, Delta X = -0.0030000 m VT = 0.025149079 Vs 13:08:44 Magnet Current for MAIN, Imag = 200.1216 A Vtrans = 2.001168 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:08:51 Integrated Voltage Measurement X0 = -0.0210000 m, Delta X = 0.0030000 m VT = -0.025138703 Vs 13:08:58 Integrated Voltage Measurement X0 = -0.0210000 m, Delta X = -0.0030000 m VT = 0.025149106 Vs 13:08:59 Magnet Current for MAIN, Imag = 200.1219 A Vtrans = 2.001171 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:09:06 Integrated Voltage Measurement X0 = -0.0210000 m, Delta X = 0.0030000 m VT = -0.025140468 Vs 13:09:13 Integrated Voltage Measurement X0 = -0.0210000 m, Delta X = -0.0030000 m VT = 0.025147541 Vs 13:09:14 Magnet Current for MAIN, Imag = 200.1215 A Vtrans = 2.001167 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:09:21 Integrated Voltage Measurement X0 = -0.0210000 m, Delta X = 0.0030000 m VT = -0.025131609 Vs 13:09:28 Integrated Voltage Measurement X0 = -0.0210000 m, Delta X = -0.0030000 m VT = 0.025145937 Vs 13:09:28 Magnet Current for MAIN, Imag = 200.1216 A Vtrans = 2.001168 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:09:35 Integrated Voltage Measurement X0 = -0.0210000 m, Delta X = 0.0030000 m VT = -0.025140259 Vs 13:09:42 Integrated Voltage Measurement X0 = -0.0210000 m, Delta X = -0.0030000 m VT = 0.025153855 Vs 13:09:42 Integrated Voltage Average and RMS of Measurements X0 = -0.0210000 m, Delta X = 0.0030000 m VT = -0.025143928 +- 0.000002838 Vs 13:09:42 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0210000 m, dx = 0.0030000 m, Nturns = 10.0 VT = -0.025143928 +- 0.000002838 Vs BL = -0.83813094 +- 0.00009460 Tm 13:09:42 Integrated Voltage Measurement... 13:09:43 Magnet Current for MAIN, Imag = 200.1216 A Vtrans = 2.001168 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:09:51 Integrated Voltage Measurement X0 = -0.0180000 m, Delta X = 0.0030000 m VT = -0.025139709 Vs 13:09:58 Integrated Voltage Measurement X0 = -0.0180000 m, Delta X = -0.0030000 m VT = 0.025152303 Vs 13:09:59 Magnet Current for MAIN, Imag = 200.1216 A Vtrans = 2.001168 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:10:06 Integrated Voltage Measurement X0 = -0.0180000 m, Delta X = 0.0030000 m VT = -0.025143189 Vs 13:10:13 Integrated Voltage Measurement X0 = -0.0180000 m, Delta X = -0.0030000 m VT = 0.025156268 Vs 13:10:14 Magnet Current for MAIN, Imag = 200.1216 A Vtrans = 2.001168 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:10:21 Integrated Voltage Measurement X0 = -0.0180000 m, Delta X = 0.0030000 m VT = -0.025146185 Vs 13:10:28 Integrated Voltage Measurement X0 = -0.0180000 m, Delta X = -0.0030000 m VT = 0.025153812 Vs 13:10:28 Magnet Current for MAIN, Imag = 200.1215 A Vtrans = 2.001167 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:10:36 Integrated Voltage Measurement X0 = -0.0180000 m, Delta X = 0.0030000 m VT = -0.025140916 Vs 13:10:43 Integrated Voltage Measurement X0 = -0.0180000 m, Delta X = -0.0030000 m VT = 0.025157081 Vs 13:10:43 Magnet Current for MAIN, Imag = 200.1211 A Vtrans = 2.001163 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:10:50 Integrated Voltage Measurement X0 = -0.0180000 m, Delta X = 0.0030000 m VT = -0.025142794 Vs 13:10:57 Integrated Voltage Measurement X0 = -0.0180000 m, Delta X = -0.0030000 m VT = 0.025154051 Vs 13:10:57 Integrated Voltage Average and RMS of Measurements X0 = -0.0180000 m, Delta X = 0.0030000 m VT = -0.025148631 +- 0.000001424 Vs 13:10:57 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0180000 m, dx = 0.0030000 m, Nturns = 10.0 VT = -0.025148631 +- 0.000001424 Vs BL = -0.83828769 +- 0.00004748 Tm 13:10:57 Integrated Voltage Measurement... 13:10:58 Magnet Current for MAIN, Imag = 200.1210 A Vtrans = 2.001162 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:11:06 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0030000 m VT = -0.025146001 Vs 13:11:13 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0030000 m VT = 0.025159856 Vs 13:11:14 Magnet Current for MAIN, Imag = 200.1210 A Vtrans = 2.001162 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:11:21 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0030000 m VT = -0.025147156 Vs 13:11:28 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0030000 m VT = 0.025159109 Vs 13:11:29 Magnet Current for MAIN, Imag = 200.1216 A Vtrans = 2.001168 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:11:36 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0030000 m VT = -0.025145744 Vs 13:11:43 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0030000 m VT = 0.025162844 Vs 13:11:43 Magnet Current for MAIN, Imag = 200.1211 A Vtrans = 2.001163 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:11:50 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0030000 m VT = -0.025152558 Vs 13:11:57 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0030000 m VT = 0.025158478 Vs 13:11:58 Magnet Current for MAIN, Imag = 200.1211 A Vtrans = 2.001163 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:12:05 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0030000 m VT = -0.025143316 Vs 13:12:12 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0030000 m VT = 0.025162423 Vs 13:12:12 Integrated Voltage Average and RMS of Measurements X0 = -0.0150000 m, Delta X = 0.0030000 m VT = -0.025153749 +- 0.000001025 Vs 13:12:12 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0150000 m, dx = 0.0030000 m, Nturns = 10.0 VT = -0.025153749 +- 0.000001025 Vs BL = -0.83845828 +- 0.00003417 Tm 13:12:12 Integrated Voltage Measurement... 13:12:13 Magnet Current for MAIN, Imag = 200.1215 A Vtrans = 2.001167 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:12:21 Integrated Voltage Measurement X0 = -0.0120000 m, Delta X = 0.0030000 m VT = -0.025154300 Vs 13:12:28 Integrated Voltage Measurement X0 = -0.0120000 m, Delta X = -0.0030000 m VT = 0.025164124 Vs 13:12:29 Magnet Current for MAIN, Imag = 200.1211 A Vtrans = 2.001163 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:12:36 Integrated Voltage Measurement X0 = -0.0120000 m, Delta X = 0.0030000 m VT = -0.025152557 Vs 13:12:43 Integrated Voltage Measurement X0 = -0.0120000 m, Delta X = -0.0030000 m VT = 0.025158464 Vs 13:12:44 Magnet Current for MAIN, Imag = 200.1214 A Vtrans = 2.001166 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:12:51 Integrated Voltage Measurement X0 = -0.0120000 m, Delta X = 0.0030000 m VT = -0.025151422 Vs 13:12:58 Integrated Voltage Measurement X0 = -0.0120000 m, Delta X = -0.0030000 m VT = 0.025161575 Vs 13:12:58 Magnet Current for MAIN, Imag = 200.1219 A Vtrans = 2.001171 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:13:05 Integrated Voltage Measurement X0 = -0.0120000 m, Delta X = 0.0030000 m VT = -0.025151949 Vs 13:13:12 Integrated Voltage Measurement X0 = -0.0120000 m, Delta X = -0.0030000 m VT = 0.025157375 Vs 13:13:13 Magnet Current for MAIN, Imag = 200.1214 A Vtrans = 2.001166 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:13:20 Integrated Voltage Measurement X0 = -0.0120000 m, Delta X = 0.0030000 m VT = -0.025150456 Vs 13:13:27 Integrated Voltage Measurement X0 = -0.0120000 m, Delta X = -0.0030000 m VT = 0.025157577 Vs 13:13:27 Integrated Voltage Average and RMS of Measurements X0 = -0.0120000 m, Delta X = 0.0030000 m VT = -0.025155980 +- 0.000001818 Vs 13:13:27 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0120000 m, dx = 0.0030000 m, Nturns = 10.0 VT = -0.025155980 +- 0.000001818 Vs BL = -0.83853266 +- 0.00006060 Tm 13:13:27 Integrated Voltage Measurement... 13:13:28 Magnet Current for MAIN, Imag = 200.1211 A Vtrans = 2.001163 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:13:36 Integrated Voltage Measurement X0 = -0.0090000 m, Delta X = 0.0030000 m VT = -0.025161279 Vs 13:13:43 Integrated Voltage Measurement X0 = -0.0090000 m, Delta X = -0.0030000 m VT = 0.025169407 Vs 13:13:44 Magnet Current for MAIN, Imag = 200.1211 A Vtrans = 2.001163 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:13:51 Integrated Voltage Measurement X0 = -0.0090000 m, Delta X = 0.0030000 m VT = -0.025156857 Vs 13:13:58 Integrated Voltage Measurement X0 = -0.0090000 m, Delta X = -0.0030000 m VT = 0.025169900 Vs 13:13:58 Magnet Current for MAIN, Imag = 200.1209 A Vtrans = 2.001161 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:14:05 Integrated Voltage Measurement X0 = -0.0090000 m, Delta X = 0.0030000 m VT = -0.025153661 Vs 13:14:12 Integrated Voltage Measurement X0 = -0.0090000 m, Delta X = -0.0030000 m VT = 0.025169911 Vs 13:14:13 Magnet Current for MAIN, Imag = 200.1214 A Vtrans = 2.001166 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:14:20 Integrated Voltage Measurement X0 = -0.0090000 m, Delta X = 0.0030000 m VT = -0.025153424 Vs 13:14:27 Integrated Voltage Measurement X0 = -0.0090000 m, Delta X = -0.0030000 m VT = 0.025167667 Vs 13:14:28 Magnet Current for MAIN, Imag = 200.1212 A Vtrans = 2.001165 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:14:35 Integrated Voltage Measurement X0 = -0.0090000 m, Delta X = 0.0030000 m VT = -0.025162424 Vs 13:14:42 Integrated Voltage Measurement X0 = -0.0090000 m, Delta X = -0.0030000 m VT = 0.025166228 Vs 13:14:42 Integrated Voltage Average and RMS of Measurements X0 = -0.0090000 m, Delta X = 0.0030000 m VT = -0.025163076 +- 0.000001724 Vs 13:14:42 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0090000 m, dx = 0.0030000 m, Nturns = 10.0 VT = -0.025163076 +- 0.000001724 Vs BL = -0.83876920 +- 0.00005747 Tm 13:14:42 Integrated Voltage Measurement... 13:14:43 Magnet Current for MAIN, Imag = 200.1212 A Vtrans = 2.001165 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:14:51 Integrated Voltage Measurement X0 = -0.0060000 m, Delta X = 0.0030000 m VT = -0.025160773 Vs 13:14:58 Integrated Voltage Measurement X0 = -0.0060000 m, Delta X = -0.0030000 m VT = 0.025160742 Vs 13:14:59 Magnet Current for MAIN, Imag = 200.1212 A Vtrans = 2.001165 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:15:06 Integrated Voltage Measurement X0 = -0.0060000 m, Delta X = 0.0030000 m VT = -0.025156905 Vs 13:15:13 Integrated Voltage Measurement X0 = -0.0060000 m, Delta X = -0.0030000 m VT = 0.025164839 Vs 13:15:13 Magnet Current for MAIN, Imag = 200.1210 A Vtrans = 2.001162 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:15:20 Integrated Voltage Measurement X0 = -0.0060000 m, Delta X = 0.0030000 m VT = -0.025159004 Vs 13:15:27 Integrated Voltage Measurement X0 = -0.0060000 m, Delta X = -0.0030000 m VT = 0.025161058 Vs 13:15:28 Magnet Current for MAIN, Imag = 200.1209 A Vtrans = 2.001161 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:15:35 Integrated Voltage Measurement X0 = -0.0060000 m, Delta X = 0.0030000 m VT = -0.025158586 Vs 13:15:42 Integrated Voltage Measurement X0 = -0.0060000 m, Delta X = -0.0030000 m VT = 0.025164137 Vs 13:15:43 Magnet Current for MAIN, Imag = 200.1212 A Vtrans = 2.001165 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:15:50 Integrated Voltage Measurement X0 = -0.0060000 m, Delta X = 0.0030000 m VT = -0.025159622 Vs 13:15:57 Integrated Voltage Measurement X0 = -0.0060000 m, Delta X = -0.0030000 m VT = 0.025164902 Vs 13:15:57 Integrated Voltage Average and RMS of Measurements X0 = -0.0060000 m, Delta X = 0.0030000 m VT = -0.025161057 +- 0.000000738 Vs 13:15:57 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0060000 m, dx = 0.0030000 m, Nturns = 10.0 VT = -0.025161057 +- 0.000000738 Vs BL = -0.83870189 +- 0.00002459 Tm 13:15:57 Integrated Voltage Measurement... 13:15:58 Magnet Current for MAIN, Imag = 200.1212 A Vtrans = 2.001165 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:16:06 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = 0.0030000 m VT = -0.025169017 Vs 13:16:13 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = -0.0030000 m VT = 0.025170971 Vs 13:16:13 Magnet Current for MAIN, Imag = 200.1212 A Vtrans = 2.001165 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:16:20 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = 0.0030000 m VT = -0.025166783 Vs 13:16:27 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = -0.0030000 m VT = 0.025170355 Vs 13:16:28 Magnet Current for MAIN, Imag = 200.1211 A Vtrans = 2.001163 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:16:35 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = 0.0030000 m VT = -0.025163504 Vs 13:16:42 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = -0.0030000 m VT = 0.025172088 Vs 13:16:43 Magnet Current for MAIN, Imag = 200.1210 A Vtrans = 2.001162 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:16:50 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = 0.0030000 m VT = -0.025170124 Vs 13:16:57 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = -0.0030000 m VT = 0.025169946 Vs 13:16:58 Magnet Current for MAIN, Imag = 200.1211 A Vtrans = 2.001163 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:17:05 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = 0.0030000 m VT = -0.025170038 Vs 13:17:12 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = -0.0030000 m VT = 0.025172732 Vs 13:17:12 Integrated Voltage Average and RMS of Measurements X0 = -0.0030000 m, Delta X = 0.0030000 m VT = -0.025169556 +- 0.000001252 Vs 13:17:12 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0030000 m, dx = 0.0030000 m, Nturns = 10.0 VT = -0.025169556 +- 0.000001252 Vs BL = -0.83898519 +- 0.00004173 Tm 13:17:12 Integrated Voltage Measurement... 13:17:12 Magnet Current for MAIN, Imag = 200.1210 A Vtrans = 2.001162 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:17:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0030000 m VT = -0.025160891 Vs 13:17:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0030000 m VT = 0.025163241 Vs 13:17:28 Magnet Current for MAIN, Imag = 200.1207 A Vtrans = 2.001159 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:17:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0030000 m VT = -0.025162314 Vs 13:17:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0030000 m VT = 0.025166606 Vs 13:17:43 Magnet Current for MAIN, Imag = 200.1215 A Vtrans = 2.001167 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:17:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0030000 m VT = -0.025162915 Vs 13:17:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0030000 m VT = 0.025163441 Vs 13:17:58 Magnet Current for MAIN, Imag = 200.1210 A Vtrans = 2.001162 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:18:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0030000 m VT = -0.025162709 Vs 13:18:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0030000 m VT = 0.025170861 Vs 13:18:12 Magnet Current for MAIN, Imag = 200.1212 A Vtrans = 2.001165 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:18:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0030000 m VT = -0.025166115 Vs 13:18:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0030000 m VT = 0.025169309 Vs 13:18:26 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0030000 m VT = -0.025164840 +- 0.000002128 Vs 13:18:26 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0030000 m, Nturns = 10.0 VT = -0.025164840 +- 0.000002128 Vs BL = -0.83882801 +- 0.00007092 Tm 13:18:26 Integrated Voltage Measurement... 13:18:27 Magnet Current for MAIN, Imag = 200.1209 A Vtrans = 2.001161 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:18:35 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = 0.0030000 m VT = -0.025170434 Vs 13:18:42 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = -0.0030000 m VT = 0.025171678 Vs 13:18:43 Magnet Current for MAIN, Imag = 200.1209 A Vtrans = 2.001161 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:18:50 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = 0.0030000 m VT = -0.025159055 Vs 13:18:57 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = -0.0030000 m VT = 0.025173429 Vs 13:18:58 Magnet Current for MAIN, Imag = 200.1212 A Vtrans = 2.001165 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:19:05 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = 0.0030000 m VT = -0.025163181 Vs 13:19:12 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = -0.0030000 m VT = 0.025168656 Vs 13:19:12 Magnet Current for MAIN, Imag = 200.1210 A Vtrans = 2.001162 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:19:19 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = 0.0030000 m VT = -0.025170742 Vs 13:19:26 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = -0.0030000 m VT = 0.025172195 Vs 13:19:27 Magnet Current for MAIN, Imag = 200.1214 A Vtrans = 2.001166 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:19:34 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = 0.0030000 m VT = -0.025162181 Vs 13:19:41 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = -0.0030000 m VT = 0.025174127 Vs 13:19:41 Integrated Voltage Average and RMS of Measurements X0 = 0.0030000 m, Delta X = 0.0030000 m VT = -0.025168568 +- 0.000002332 Vs 13:19:41 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0030000 m, dx = 0.0030000 m, Nturns = 10.0 VT = -0.025168568 +- 0.000002332 Vs BL = -0.83895226 +- 0.00007775 Tm 13:19:41 Integrated Voltage Measurement... 13:19:42 Magnet Current for MAIN, Imag = 200.1214 A Vtrans = 2.001166 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:19:50 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = 0.0030000 m VT = -0.025159506 Vs 13:19:57 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = -0.0030000 m VT = 0.025170741 Vs 13:19:58 Magnet Current for MAIN, Imag = 200.1214 A Vtrans = 2.001166 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:20:05 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = 0.0030000 m VT = -0.025165688 Vs 13:20:12 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = -0.0030000 m VT = 0.025168528 Vs 13:20:13 Magnet Current for MAIN, Imag = 200.1211 A Vtrans = 2.001163 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:20:20 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = 0.0030000 m VT = -0.025160074 Vs 13:20:27 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = -0.0030000 m VT = 0.025171932 Vs 13:20:27 Magnet Current for MAIN, Imag = 200.1210 A Vtrans = 2.001162 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:20:34 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = 0.0030000 m VT = -0.025160636 Vs 13:20:41 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = -0.0030000 m VT = 0.025171410 Vs 13:20:42 Magnet Current for MAIN, Imag = 200.1215 A Vtrans = 2.001167 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:20:49 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = 0.0030000 m VT = -0.025160237 Vs 13:20:56 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = -0.0030000 m VT = 0.025167480 Vs 13:20:56 Integrated Voltage Average and RMS of Measurements X0 = 0.0060000 m, Delta X = 0.0030000 m VT = -0.025165623 +- 0.000001084 Vs 13:20:56 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0060000 m, dx = 0.0030000 m, Nturns = 10.0 VT = -0.025165623 +- 0.000001084 Vs BL = -0.83885411 +- 0.00003613 Tm 13:20:56 Integrated Voltage Measurement... 13:20:57 Magnet Current for MAIN, Imag = 200.1209 A Vtrans = 2.001161 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:21:05 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = 0.0030000 m VT = -0.025161603 Vs 13:21:12 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = -0.0030000 m VT = 0.025169176 Vs 13:21:13 Magnet Current for MAIN, Imag = 200.1212 A Vtrans = 2.001165 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:21:20 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = 0.0030000 m VT = -0.025167916 Vs 13:21:27 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = -0.0030000 m VT = 0.025167387 Vs 13:21:28 Magnet Current for MAIN, Imag = 200.1211 A Vtrans = 2.001163 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:21:35 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = 0.0030000 m VT = -0.025164650 Vs 13:21:42 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = -0.0030000 m VT = 0.025167726 Vs 13:21:42 Magnet Current for MAIN, Imag = 200.1209 A Vtrans = 2.001161 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:21:49 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = 0.0030000 m VT = -0.025167061 Vs 13:21:56 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = -0.0030000 m VT = 0.025166996 Vs 13:21:57 Magnet Current for MAIN, Imag = 200.1210 A Vtrans = 2.001162 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:22:04 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = 0.0030000 m VT = -0.025157048 Vs 13:22:11 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = -0.0030000 m VT = 0.025170532 Vs 13:22:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0090000 m, Delta X = 0.0030000 m VT = -0.025166010 +- 0.000001347 Vs 13:22:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0090000 m, dx = 0.0030000 m, Nturns = 10.0 VT = -0.025166010 +- 0.000001347 Vs BL = -0.83886699 +- 0.00004491 Tm 13:22:11 Integrated Voltage Measurement... 13:22:12 Magnet Current for MAIN, Imag = 200.1209 A Vtrans = 2.001161 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:22:20 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = 0.0030000 m VT = -0.025149211 Vs 13:22:27 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = -0.0030000 m VT = 0.025162082 Vs 13:22:28 Magnet Current for MAIN, Imag = 200.1209 A Vtrans = 2.001161 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:22:35 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = 0.0030000 m VT = -0.025155264 Vs 13:22:42 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = -0.0030000 m VT = 0.025162055 Vs 13:22:42 Magnet Current for MAIN, Imag = 200.1212 A Vtrans = 2.001165 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:22:49 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = 0.0030000 m VT = -0.025153793 Vs 13:22:56 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = -0.0030000 m VT = 0.025156457 Vs 13:22:57 Magnet Current for MAIN, Imag = 200.1210 A Vtrans = 2.001162 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:23:04 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = 0.0030000 m VT = -0.025150055 Vs 13:23:11 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = -0.0030000 m VT = 0.025156075 Vs 13:23:12 Magnet Current for MAIN, Imag = 200.1206 A Vtrans = 2.001158 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:23:19 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = 0.0030000 m VT = -0.025152399 Vs 13:23:26 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = -0.0030000 m VT = 0.025157832 Vs 13:23:26 Integrated Voltage Average and RMS of Measurements X0 = 0.0120000 m, Delta X = 0.0030000 m VT = -0.025155522 +- 0.000001801 Vs 13:23:26 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0120000 m, dx = 0.0030000 m, Nturns = 10.0 VT = -0.025155522 +- 0.000001801 Vs BL = -0.83851742 +- 0.00006004 Tm 13:23:26 Integrated Voltage Measurement... 13:23:27 Magnet Current for MAIN, Imag = 200.1207 A Vtrans = 2.001159 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:23:35 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0030000 m VT = -0.025157490 Vs 13:23:42 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0030000 m VT = 0.025160846 Vs 13:23:43 Magnet Current for MAIN, Imag = 200.1209 A Vtrans = 2.001161 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:23:50 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0030000 m VT = -0.025155811 Vs 13:23:57 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0030000 m VT = 0.025155805 Vs 13:23:57 Magnet Current for MAIN, Imag = 200.1207 A Vtrans = 2.001159 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:24:04 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0030000 m VT = -0.025142777 Vs 13:24:11 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0030000 m VT = 0.025154161 Vs 13:24:12 Magnet Current for MAIN, Imag = 200.1206 A Vtrans = 2.001158 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:24:19 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0030000 m VT = -0.025145557 Vs 13:24:26 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0030000 m VT = 0.025157221 Vs 13:24:27 Magnet Current for MAIN, Imag = 200.1204 A Vtrans = 2.001156 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:24:34 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0030000 m VT = -0.025145900 Vs 13:24:41 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0030000 m VT = 0.025156351 Vs 13:24:41 Integrated Voltage Average and RMS of Measurements X0 = 0.0150000 m, Delta X = 0.0030000 m VT = -0.025153192 +- 0.000003805 Vs 13:24:41 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0150000 m, dx = 0.0030000 m, Nturns = 10.0 VT = -0.025153192 +- 0.000003805 Vs BL = -0.83843973 +- 0.00012683 Tm 13:24:41 Integrated Voltage Measurement... 13:24:42 Magnet Current for MAIN, Imag = 200.1207 A Vtrans = 2.001159 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:24:50 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = 0.0030000 m VT = -0.025145789 Vs 13:24:57 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = -0.0030000 m VT = 0.025150686 Vs 13:24:58 Magnet Current for MAIN, Imag = 200.1205 A Vtrans = 2.001157 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:25:05 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = 0.0030000 m VT = -0.025146964 Vs 13:25:12 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = -0.0030000 m VT = 0.025153271 Vs 13:25:12 Magnet Current for MAIN, Imag = 200.1205 A Vtrans = 2.001157 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:25:19 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = 0.0030000 m VT = -0.025149301 Vs 13:25:26 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = -0.0030000 m VT = 0.025151871 Vs 13:25:27 Magnet Current for MAIN, Imag = 200.1211 A Vtrans = 2.001163 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:25:34 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = 0.0030000 m VT = -0.025145936 Vs 13:25:41 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = -0.0030000 m VT = 0.025155255 Vs 13:25:42 Magnet Current for MAIN, Imag = 200.1206 A Vtrans = 2.001158 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:25:49 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = 0.0030000 m VT = -0.025148116 Vs 13:25:56 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = -0.0030000 m VT = 0.025153380 Vs 13:25:56 Integrated Voltage Average and RMS of Measurements X0 = 0.0180000 m, Delta X = 0.0030000 m VT = -0.025150057 +- 0.000000934 Vs 13:25:56 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0180000 m, dx = 0.0030000 m, Nturns = 10.0 VT = -0.025150057 +- 0.000000934 Vs BL = -0.83833523 +- 0.00003113 Tm 13:25:56 Integrated Voltage Measurement... 13:25:57 Magnet Current for MAIN, Imag = 200.1210 A Vtrans = 2.001162 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:26:05 Integrated Voltage Measurement X0 = 0.0210000 m, Delta X = 0.0030000 m VT = -0.025132954 Vs 13:26:12 Integrated Voltage Measurement X0 = 0.0210000 m, Delta X = -0.0030000 m VT = 0.025144587 Vs 13:26:13 Magnet Current for MAIN, Imag = 200.1207 A Vtrans = 2.001159 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:26:20 Integrated Voltage Measurement X0 = 0.0210000 m, Delta X = 0.0030000 m VT = -0.025145133 Vs 13:26:27 Integrated Voltage Measurement X0 = 0.0210000 m, Delta X = -0.0030000 m VT = 0.025148326 Vs 13:26:28 Magnet Current for MAIN, Imag = 200.1209 A Vtrans = 2.001161 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:26:35 Integrated Voltage Measurement X0 = 0.0210000 m, Delta X = 0.0030000 m VT = -0.025139868 Vs 13:26:42 Integrated Voltage Measurement X0 = 0.0210000 m, Delta X = -0.0030000 m VT = 0.025146020 Vs 13:26:42 Magnet Current for MAIN, Imag = 200.1209 A Vtrans = 2.001161 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:26:49 Integrated Voltage Measurement X0 = 0.0210000 m, Delta X = 0.0030000 m VT = -0.025139732 Vs 13:26:57 Integrated Voltage Measurement X0 = 0.0210000 m, Delta X = -0.0030000 m VT = 0.025146301 Vs 13:26:57 Magnet Current for MAIN, Imag = 200.1207 A Vtrans = 2.001159 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:27:04 Integrated Voltage Measurement X0 = 0.0210000 m, Delta X = 0.0030000 m VT = -0.025144394 Vs 13:27:11 Integrated Voltage Measurement X0 = 0.0210000 m, Delta X = -0.0030000 m VT = 0.025144971 Vs 13:27:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0210000 m, Delta X = 0.0030000 m VT = -0.025143229 +- 0.000002622 Vs 13:27:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0210000 m, dx = 0.0030000 m, Nturns = 10.0 VT = -0.025143229 +- 0.000002622 Vs BL = -0.83810762 +- 0.00008740 Tm 13:27:11 Integrated Voltage Measurement... 13:27:12 Magnet Current for MAIN, Imag = 200.1215 A Vtrans = 2.001167 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:27:20 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = 0.0030000 m VT = -0.025137696 Vs 13:27:27 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = -0.0030000 m VT = 0.025139979 Vs 13:27:28 Magnet Current for MAIN, Imag = 200.1214 A Vtrans = 2.001166 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:27:35 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = 0.0030000 m VT = -0.025133161 Vs 13:27:42 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = -0.0030000 m VT = 0.025141151 Vs 13:27:43 Magnet Current for MAIN, Imag = 200.1209 A Vtrans = 2.001161 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:27:50 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = 0.0030000 m VT = -0.025131781 Vs 13:27:57 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = -0.0030000 m VT = 0.025140696 Vs 13:27:58 Magnet Current for MAIN, Imag = 200.1210 A Vtrans = 2.001162 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:28:05 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = 0.0030000 m VT = -0.025131776 Vs 13:28:12 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = -0.0030000 m VT = 0.025135869 Vs 13:28:12 Magnet Current for MAIN, Imag = 200.1211 A Vtrans = 2.001163 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:28:19 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = 0.0030000 m VT = -0.025132886 Vs 13:28:26 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = -0.0030000 m VT = 0.025136675 Vs 13:28:26 Integrated Voltage Average and RMS of Measurements X0 = 0.0240000 m, Delta X = 0.0030000 m VT = -0.025136167 +- 0.000001763 Vs 13:28:26 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0240000 m, dx = 0.0030000 m, Nturns = 10.0 VT = -0.025136167 +- 0.000001763 Vs BL = -0.83787224 +- 0.00005875 Tm 13:28:26 Integrated Voltage Measurement... 13:28:27 Magnet Current for MAIN, Imag = 200.1214 A Vtrans = 2.001166 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:28:35 Integrated Voltage Measurement X0 = 0.0270000 m, Delta X = 0.0030000 m VT = -0.025128885 Vs 13:28:42 Integrated Voltage Measurement X0 = 0.0270000 m, Delta X = -0.0030000 m VT = 0.025137493 Vs 13:28:43 Magnet Current for MAIN, Imag = 200.1209 A Vtrans = 2.001161 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:28:50 Integrated Voltage Measurement X0 = 0.0270000 m, Delta X = 0.0030000 m VT = -0.025139723 Vs 13:28:57 Integrated Voltage Measurement X0 = 0.0270000 m, Delta X = -0.0030000 m VT = 0.025134653 Vs 13:28:58 Magnet Current for MAIN, Imag = 200.1210 A Vtrans = 2.001162 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:29:05 Integrated Voltage Measurement X0 = 0.0270000 m, Delta X = 0.0030000 m VT = -0.025135528 Vs 13:29:12 Integrated Voltage Measurement X0 = 0.0270000 m, Delta X = -0.0030000 m VT = 0.025135673 Vs 13:29:12 Magnet Current for MAIN, Imag = 200.1211 A Vtrans = 2.001163 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:29:19 Integrated Voltage Measurement X0 = 0.0270000 m, Delta X = 0.0030000 m VT = -0.025135495 Vs 13:29:26 Integrated Voltage Measurement X0 = 0.0270000 m, Delta X = -0.0030000 m VT = 0.025139941 Vs 13:29:27 Magnet Current for MAIN, Imag = 200.1215 A Vtrans = 2.001167 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:29:34 Integrated Voltage Measurement X0 = 0.0270000 m, Delta X = 0.0030000 m VT = -0.025127902 Vs 13:29:41 Integrated Voltage Measurement X0 = 0.0270000 m, Delta X = -0.0030000 m VT = 0.025133934 Vs 13:29:41 Integrated Voltage Average and RMS of Measurements X0 = 0.0270000 m, Delta X = 0.0030000 m VT = -0.025134923 +- 0.000002547 Vs 13:29:41 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0270000 m, dx = 0.0030000 m, Nturns = 10.0 VT = -0.025134923 +- 0.000002547 Vs BL = -0.83783076 +- 0.00008491 Tm 13:29:41 Integrated Voltage Measurement... 13:29:42 Magnet Current for MAIN, Imag = 200.1211 A Vtrans = 2.001163 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:29:50 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0030000 m VT = -0.025119025 Vs 13:29:57 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0030000 m VT = 0.025122825 Vs 13:29:58 Magnet Current for MAIN, Imag = 200.1216 A Vtrans = 2.001168 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:30:05 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0030000 m VT = -0.025119007 Vs 13:30:12 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0030000 m VT = 0.025125881 Vs 13:30:12 Magnet Current for MAIN, Imag = 200.1206 A Vtrans = 2.001158 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:30:19 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0030000 m VT = -0.025119610 Vs 13:30:26 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0030000 m VT = 0.025120924 Vs 13:30:27 Magnet Current for MAIN, Imag = 200.1204 A Vtrans = 2.001156 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:30:34 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0030000 m VT = -0.025118877 Vs 13:30:41 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0030000 m VT = 0.025127647 Vs 13:30:42 Magnet Current for MAIN, Imag = 200.1210 A Vtrans = 2.001162 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:30:49 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0030000 m VT = -0.025116673 Vs 13:30:56 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0030000 m VT = 0.025123455 Vs 13:30:56 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0030000 m VT = -0.025121392 +- 0.000001253 Vs 13:30:56 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0030000 m, Nturns = 10.0 VT = -0.025121392 +- 0.000001253 Vs BL = -0.83737975 +- 0.00004177 Tm 13:30:56 Integrated Voltage Measurement... 13:30:57 Magnet Current for MAIN, Imag = 200.1214 A Vtrans = 2.001166 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:31:05 Integrated Voltage Measurement X0 = 0.0330000 m, Delta X = 0.0030000 m VT = -0.025118317 Vs 13:31:12 Integrated Voltage Measurement X0 = 0.0330000 m, Delta X = -0.0030000 m VT = 0.025124852 Vs 13:31:13 Magnet Current for MAIN, Imag = 200.1214 A Vtrans = 2.001166 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:31:20 Integrated Voltage Measurement X0 = 0.0330000 m, Delta X = 0.0030000 m VT = -0.025118965 Vs 13:31:27 Integrated Voltage Measurement X0 = 0.0330000 m, Delta X = -0.0030000 m VT = 0.025126605 Vs 13:31:27 Magnet Current for MAIN, Imag = 200.1210 A Vtrans = 2.001162 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:31:34 Integrated Voltage Measurement X0 = 0.0330000 m, Delta X = 0.0030000 m VT = -0.025116554 Vs 13:31:41 Integrated Voltage Measurement X0 = 0.0330000 m, Delta X = -0.0030000 m VT = 0.025126542 Vs 13:31:42 Magnet Current for MAIN, Imag = 200.1209 A Vtrans = 2.001161 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:31:49 Integrated Voltage Measurement X0 = 0.0330000 m, Delta X = 0.0030000 m VT = -0.025122769 Vs 13:31:56 Integrated Voltage Measurement X0 = 0.0330000 m, Delta X = -0.0030000 m VT = 0.025122539 Vs 13:31:57 Magnet Current for MAIN, Imag = 200.1215 A Vtrans = 2.001167 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:32:04 Integrated Voltage Measurement X0 = 0.0330000 m, Delta X = 0.0030000 m VT = -0.025111612 Vs 13:32:11 Integrated Voltage Measurement X0 = 0.0330000 m, Delta X = -0.0030000 m VT = 0.025123504 Vs 13:32:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0330000 m, Delta X = 0.0030000 m VT = -0.025121226 +- 0.000001906 Vs 13:32:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0330000 m, dx = 0.0030000 m, Nturns = 10.0 VT = -0.025121226 +- 0.000001906 Vs BL = -0.83737420 +- 0.00006352 Tm 13:32:11 Integrated Voltage Measurement... 13:32:12 Magnet Current for MAIN, Imag = 200.1211 A Vtrans = 2.001163 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:32:20 Integrated Voltage Measurement X0 = 0.0360000 m, Delta X = 0.0030000 m VT = -0.025112051 Vs 13:32:27 Integrated Voltage Measurement X0 = 0.0360000 m, Delta X = -0.0030000 m VT = 0.025126126 Vs 13:32:27 Magnet Current for MAIN, Imag = 200.1214 A Vtrans = 2.001166 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:32:34 Integrated Voltage Measurement X0 = 0.0360000 m, Delta X = 0.0030000 m VT = -0.025113844 Vs 13:32:41 Integrated Voltage Measurement X0 = 0.0360000 m, Delta X = -0.0030000 m VT = 0.025122716 Vs 13:32:42 Magnet Current for MAIN, Imag = 200.1211 A Vtrans = 2.001163 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:32:49 Integrated Voltage Measurement X0 = 0.0360000 m, Delta X = 0.0030000 m VT = -0.025112441 Vs 13:32:56 Integrated Voltage Measurement X0 = 0.0360000 m, Delta X = -0.0030000 m VT = 0.025120413 Vs 13:32:57 Magnet Current for MAIN, Imag = 200.1210 A Vtrans = 2.001162 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:33:04 Integrated Voltage Measurement X0 = 0.0360000 m, Delta X = 0.0030000 m VT = -0.025113671 Vs 13:33:11 Integrated Voltage Measurement X0 = 0.0360000 m, Delta X = -0.0030000 m VT = 0.025123840 Vs 13:33:12 Magnet Current for MAIN, Imag = 200.1207 A Vtrans = 2.001159 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:33:19 Integrated Voltage Measurement X0 = 0.0360000 m, Delta X = 0.0030000 m VT = -0.025112476 Vs 13:33:26 Integrated Voltage Measurement X0 = 0.0360000 m, Delta X = -0.0030000 m VT = 0.025122445 Vs 13:33:26 Integrated Voltage Average and RMS of Measurements X0 = 0.0360000 m, Delta X = 0.0030000 m VT = -0.025118002 +- 0.000000959 Vs 13:33:26 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0360000 m, dx = 0.0030000 m, Nturns = 10.0 VT = -0.025118002 +- 0.000000959 Vs BL = -0.83726674 +- 0.00003197 Tm 13:33:26 Integrated Voltage Measurement... 13:33:27 Magnet Current for MAIN, Imag = 200.1207 A Vtrans = 2.001159 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:33:35 Integrated Voltage Measurement X0 = 0.0390000 m, Delta X = 0.0030000 m VT = -0.025109500 Vs 13:33:42 Integrated Voltage Measurement X0 = 0.0390000 m, Delta X = -0.0030000 m VT = 0.025127172 Vs 13:33:43 Magnet Current for MAIN, Imag = 200.1212 A Vtrans = 2.001165 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:33:50 Integrated Voltage Measurement X0 = 0.0390000 m, Delta X = 0.0030000 m VT = -0.025118011 Vs 13:33:57 Integrated Voltage Measurement X0 = 0.0390000 m, Delta X = -0.0030000 m VT = 0.025120610 Vs 13:33:58 Magnet Current for MAIN, Imag = 200.1210 A Vtrans = 2.001162 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:34:05 Integrated Voltage Measurement X0 = 0.0390000 m, Delta X = 0.0030000 m VT = -0.025117830 Vs 13:34:12 Integrated Voltage Measurement X0 = 0.0390000 m, Delta X = -0.0030000 m VT = 0.025120468 Vs 13:34:13 Magnet Current for MAIN, Imag = 200.1215 A Vtrans = 2.001167 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:34:20 Integrated Voltage Measurement X0 = 0.0390000 m, Delta X = 0.0030000 m VT = -0.025115847 Vs 13:34:27 Integrated Voltage Measurement X0 = 0.0390000 m, Delta X = -0.0030000 m VT = 0.025125606 Vs 13:34:28 Magnet Current for MAIN, Imag = 200.1210 A Vtrans = 2.001162 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:34:35 Integrated Voltage Measurement X0 = 0.0390000 m, Delta X = 0.0030000 m VT = -0.025116086 Vs 13:34:42 Integrated Voltage Measurement X0 = 0.0390000 m, Delta X = -0.0030000 m VT = 0.025121722 Vs 13:34:42 Integrated Voltage Average and RMS of Measurements X0 = 0.0390000 m, Delta X = 0.0030000 m VT = -0.025119285 +- 0.000000793 Vs 13:34:42 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0390000 m, dx = 0.0030000 m, Nturns = 10.0 VT = -0.025119285 +- 0.000000793 Vs BL = -0.83730951 +- 0.00002643 Tm 13:34:42 Integrated Voltage Measurement... 13:34:42 Magnet Current for MAIN, Imag = 200.1210 A Vtrans = 2.001162 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:34:51 Integrated Voltage Measurement X0 = 0.0420000 m, Delta X = 0.0030000 m VT = -0.025117858 Vs 13:34:58 Integrated Voltage Measurement X0 = 0.0420000 m, Delta X = -0.0030000 m VT = 0.025130373 Vs 13:34:58 Magnet Current for MAIN, Imag = 200.1210 A Vtrans = 2.001162 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:35:05 Integrated Voltage Measurement X0 = 0.0420000 m, Delta X = 0.0030000 m VT = -0.025120430 Vs 13:35:12 Integrated Voltage Measurement X0 = 0.0420000 m, Delta X = -0.0030000 m VT = 0.025131492 Vs 13:35:13 Magnet Current for MAIN, Imag = 200.1210 A Vtrans = 2.001162 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:35:20 Integrated Voltage Measurement X0 = 0.0420000 m, Delta X = 0.0030000 m VT = -0.025120285 Vs 13:35:27 Integrated Voltage Measurement X0 = 0.0420000 m, Delta X = -0.0030000 m VT = 0.025128910 Vs 13:35:28 Magnet Current for MAIN, Imag = 200.1211 A Vtrans = 2.001163 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:35:35 Integrated Voltage Measurement X0 = 0.0420000 m, Delta X = 0.0030000 m VT = -0.025120146 Vs 13:35:42 Integrated Voltage Measurement X0 = 0.0420000 m, Delta X = -0.0030000 m VT = 0.025130307 Vs 13:35:43 Magnet Current for MAIN, Imag = 200.1210 A Vtrans = 2.001162 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:35:50 Integrated Voltage Measurement X0 = 0.0420000 m, Delta X = 0.0030000 m VT = -0.025120055 Vs 13:35:57 Integrated Voltage Measurement X0 = 0.0420000 m, Delta X = -0.0030000 m VT = 0.025128943 Vs 13:35:57 Integrated Voltage Average and RMS of Measurements X0 = 0.0420000 m, Delta X = 0.0030000 m VT = -0.025124880 +- 0.000000648 Vs 13:35:57 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0420000 m, dx = 0.0030000 m, Nturns = 10.0 VT = -0.025124880 +- 0.000000648 Vs BL = -0.83749600 +- 0.00002159 Tm 13:35:57 Integrated Voltage Measurement... 13:35:58 Magnet Current for MAIN, Imag = 200.1211 A Vtrans = 2.001163 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:36:06 Integrated Voltage Measurement X0 = 0.0450000 m, Delta X = 0.0030000 m VT = -0.025146603 Vs 13:36:13 Integrated Voltage Measurement X0 = 0.0450000 m, Delta X = -0.0030000 m VT = 0.025150988 Vs 13:36:13 Magnet Current for MAIN, Imag = 200.1211 A Vtrans = 2.001163 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:36:20 Integrated Voltage Measurement X0 = 0.0450000 m, Delta X = 0.0030000 m VT = -0.025140461 Vs 13:36:27 Integrated Voltage Measurement X0 = 0.0450000 m, Delta X = -0.0030000 m VT = 0.025148116 Vs 13:36:28 Magnet Current for MAIN, Imag = 200.1216 A Vtrans = 2.001168 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:36:35 Integrated Voltage Measurement X0 = 0.0450000 m, Delta X = 0.0030000 m VT = -0.025143566 Vs 13:36:42 Integrated Voltage Measurement X0 = 0.0450000 m, Delta X = -0.0030000 m VT = 0.025148105 Vs 13:36:43 Magnet Current for MAIN, Imag = 200.1214 A Vtrans = 2.001166 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:36:50 Integrated Voltage Measurement X0 = 0.0450000 m, Delta X = 0.0030000 m VT = -0.025133800 Vs 13:36:57 Integrated Voltage Measurement X0 = 0.0450000 m, Delta X = -0.0030000 m VT = 0.025145822 Vs 13:36:58 Magnet Current for MAIN, Imag = 200.1218 A Vtrans = 2.001170 V, Factor V/A = 0.010000 V/A, Zero Current = -0.004789 A 13:37:05 Integrated Voltage Measurement X0 = 0.0450000 m, Delta X = 0.0030000 m VT = -0.025141973 Vs 13:37:12 Integrated Voltage Measurement X0 = 0.0450000 m, Delta X = -0.0030000 m VT = 0.025150968 Vs 13:37:12 Integrated Voltage Average and RMS of Measurements X0 = 0.0450000 m, Delta X = 0.0030000 m VT = -0.025145040 +- 0.000002990 Vs 13:37:12 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0450000 m, dx = 0.0030000 m, Nturns = 10.0 VT = -0.025145040 +- 0.000002990 Vs BL = -0.83816801 +- 0.00009966 Tm 13:37:17 Position moved: 0.000000 m 13:37:20 Position moved: 0.000000 m 13:37:22 Magnet system MAIN current ramping to 0.0000 A...