SLAC Magnetic Measurements Date: 11-10-2025 Time: 13:21:56 Project: FACET-II Magnet Type: Dipole Magnet Name: 4595 Serial Number: 30822-4 Run Number: 10 Measurement Device: 1wire Operator: sda Comment: Degauss Currents f = 0.85 totals point = 49 Imax = 14.5 Test Currents for MAIN (A): 14.50 -12.32 10.48 -8.90 7.57 -6.43 5.47 -4.65 3.95 -3.36 2.85 -2.43 2.06 -1.75 1.49 -1.27 1.08 -0.92 0.78 -0.66 0.56 -0.48 0.41 -0.35 0.29 -0.25 0.21 -0.18 0.15 -0.13 0.11 -0.09 0.08 -0.07 0.06 -0.05 0.04 -0.04 0.03 -0.03 0.02 -0.02 0.02 -0.01 0.01 -0.01 0.01 -0.01 0.00 13:22:21 Position moved: 0.000000 m 13:22:26 Magnet Current for MAIN, Imag = 0.0013 A Vtrans = 0.000112 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 13:22:27 Magnet Current for MAIN, Imag = 0.0006 A Vtrans = 0.000050 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 13:22:28 Magnet Current for MAIN, Imag = 0.0009 A Vtrans = 0.000075 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 13:22:29 Magnet Current for MAIN, Imag = 0.0012 A Vtrans = 0.000100 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 13:22:29 Magnet Avgerage Current Measurement for MAIN : Imag = 0.0010 +- 0.0003 A 13:22:40 Initial Zero Current Measurement for MAIN, Imag_zero = 0.001011 A 13:22:40 Ambient Measurement Device(s) Being Used, type = None 13:22:41 Magnet Voltage Measurement Device(s) Being Used, type = HP34970 13:22:41 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 13:22:41 Ambient Measurement Device(s) Being Used, type = None 13:22:44 Position moved: 0.000000 m 13:22:47 Magnet system MAIN current ramping to 14.5000 A... 13:22:57 Magnet system MAIN current ramping to -12.3250 A... 13:23:14 Magnet system MAIN current ramping to 10.4763 A... 13:23:29 Magnet system MAIN current ramping to -8.9048 A... 13:23:42 Magnet system MAIN current ramping to 7.5691 A... 13:23:54 Magnet system MAIN current ramping to -6.4337 A... 13:24:04 Magnet system MAIN current ramping to 5.4687 A... 13:24:14 Magnet system MAIN current ramping to -4.6484 A... 13:24:22 Magnet system MAIN current ramping to 3.9511 A... 13:24:30 Magnet system MAIN current ramping to -3.3584 A... 13:24:37 Magnet system MAIN current ramping to 2.8547 A... 13:24:43 Magnet system MAIN current ramping to -2.4265 A... 13:24:50 Magnet system MAIN current ramping to 2.0625 A... 13:24:55 Magnet system MAIN current ramping to -1.7531 A... 13:25:01 Magnet system MAIN current ramping to 1.4902 A... 13:25:06 Magnet system MAIN current ramping to -1.2666 A... 13:25:11 Magnet system MAIN current ramping to 1.0766 A... 13:25:15 Magnet system MAIN current ramping to -0.9151 A... 13:25:20 Magnet system MAIN current ramping to 0.7779 A... 13:25:24 Magnet system MAIN current ramping to -0.6612 A... 13:25:28 Magnet system MAIN current ramping to 0.5620 A... 13:25:32 Magnet system MAIN current ramping to -0.4777 A... 13:25:36 Magnet system MAIN current ramping to 0.4061 A... 13:25:40 Magnet system MAIN current ramping to -0.3452 A... 13:25:44 Magnet system MAIN current ramping to 0.2934 A... 13:25:47 Magnet system MAIN current ramping to -0.2494 A... 13:25:51 Magnet system MAIN current ramping to 0.2120 A... 13:25:55 Magnet system MAIN current ramping to -0.1802 A... 13:25:58 Magnet system MAIN current ramping to 0.1531 A... 13:26:02 Magnet system MAIN current ramping to -0.1302 A... 13:26:06 Magnet system MAIN current ramping to 0.1106 A... 13:26:09 Magnet system MAIN current ramping to -0.0940 A... 13:26:13 Magnet system MAIN current ramping to 0.0799 A... 13:26:16 Magnet system MAIN current ramping to -0.0679 A... 13:26:20 Magnet system MAIN current ramping to 0.0578 A... 13:26:23 Magnet system MAIN current ramping to -0.0491 A... 13:26:27 Magnet system MAIN current ramping to 0.0417 A... 13:26:30 Magnet system MAIN current ramping to -0.0355 A... 13:26:34 Magnet system MAIN current ramping to 0.0301 A... 13:26:37 Magnet system MAIN current ramping to -0.0256 A... 13:26:41 Magnet system MAIN current ramping to 0.0218 A... 13:26:44 Magnet system MAIN current ramping to -0.0185 A... 13:26:47 Magnet system MAIN current ramping to 0.0157 A... 13:26:51 Magnet system MAIN current ramping to -0.0134 A... 13:26:54 Magnet system MAIN current ramping to 0.0114 A... 13:26:58 Magnet system MAIN current ramping to -0.0097 A... 13:27:01 Magnet system MAIN current ramping to 0.0082 A... 13:27:05 Magnet system MAIN current ramping to -0.0070 A... 13:27:08 Magnet system MAIN current ramping to 0.0000 A... 13:29:16 Magnet Current for MAIN, Imag = 0.0003 A Vtrans = 0.000112 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001011 A 13:29:17 Main (V) Voltage Measurement, V = 0.000100 V 13:29:23 Temperature Measurement, Probe Number = 0, T = 24.380000 C 13:29:24 Temperature Measurement, Probe Number = 1, T = 24.010000 C 13:29:25 Temperature Measurement, Probe Number = 2, T = 23.705000 C 13:29:26 Temperature Measurement, Probe Number = 3, T = 24.248000 C 13:29:26 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = Main (V), Value = 0.00 P2 = Coil_Top_Inside, Value = 24.38 P3 = Coil_Top_Outside, Value = 24.01 P4 = Core, Value = 23.70 P5 = Ambient, Value = 24.25 13:29:26 Magnetic Field Measurement Measuring the magnet strength... 13:29:26 Integrated Voltage Measurement... 13:29:27 Magnet Current for MAIN, Imag = 0.0017 A Vtrans = 0.000224 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001011 A 13:29:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000004877 Vs 13:29:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000005027 Vs 13:29:46 Magnet Current for MAIN, Imag = 0.0006 A Vtrans = 0.000137 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001011 A 13:29:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000005124 Vs 13:30:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000005172 Vs 13:30:05 Magnet Current for MAIN, Imag = 0.0006 A Vtrans = 0.000137 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001011 A 13:30:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000005048 Vs 13:30:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000004911 Vs 13:30:23 Magnet Current for MAIN, Imag = 0.0008 A Vtrans = 0.000149 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001011 A 13:30:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000004911 Vs 13:30:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000004953 Vs 13:30:40 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000000013 +- 0.000000052 Vs 13:30:40 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000000013 +- 0.000000052 Vs BL = 0.00000130 +- 0.00000515 Tm 13:30:44 Position moved: 0.000000 m 13:30:44 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00000 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00000 0.00001 0.00000 0.00000 13:30:44 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00000 0.00001 SL = 0.0000013 +- 0.0000052 Tm^2/m^n 13:30:44 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0000013 +- 0.0000052 Tm^2/m^n 13:30:47 Position moved: 0.000000 m 13:32:14 Magnet system MAIN current ramping to 14.5000 A... 13:32:25 Magnet system MAIN current ramping to -12.3250 A... 13:32:42 Magnet system MAIN current ramping to 10.4763 A... 13:32:57 Magnet system MAIN current ramping to -8.9048 A... 13:33:10 Magnet system MAIN current ramping to 7.5691 A... 13:33:22 Magnet system MAIN current ramping to -6.4337 A... 13:33:32 Magnet system MAIN current ramping to 5.4687 A... 13:33:42 Magnet system MAIN current ramping to -4.6484 A... 13:33:50 Magnet system MAIN current ramping to 3.9511 A... 13:33:58 Magnet system MAIN current ramping to -3.3584 A... 13:34:05 Magnet system MAIN current ramping to 2.8547 A... 13:34:11 Magnet system MAIN current ramping to -2.4265 A... 13:34:17 Magnet system MAIN current ramping to 2.0625 A... 13:34:23 Magnet system MAIN current ramping to -1.7531 A... 13:34:29 Magnet system MAIN current ramping to 1.4902 A... 13:34:34 Magnet system MAIN current ramping to -1.2666 A... 13:34:38 Magnet system MAIN current ramping to 1.0766 A... 13:34:43 Magnet system MAIN current ramping to -0.9151 A... 13:34:47 Magnet system MAIN current ramping to 0.7779 A... 13:34:52 Magnet system MAIN current ramping to -0.6612 A... 13:34:56 Magnet system MAIN current ramping to 0.5620 A... 13:35:00 Magnet system MAIN current ramping to -0.4777 A... 13:35:04 Magnet system MAIN current ramping to 0.4061 A... 13:35:08 Magnet system MAIN current ramping to -0.3452 A... 13:35:12 Magnet system MAIN current ramping to 0.2934 A... 13:35:15 Magnet system MAIN current ramping to -0.2494 A... 13:35:19 Magnet system MAIN current ramping to 0.2120 A... 13:35:23 Magnet system MAIN current ramping to -0.1802 A... 13:35:26 Magnet system MAIN current ramping to 0.1531 A... 13:35:30 Magnet system MAIN current ramping to -0.1302 A... 13:35:33 Magnet system MAIN current ramping to 0.1106 A... 13:35:37 Magnet system MAIN current ramping to -0.0940 A... 13:35:41 Magnet system MAIN current ramping to 0.0799 A... 13:35:44 Magnet system MAIN current ramping to -0.0679 A... 13:35:48 Magnet system MAIN current ramping to 0.0578 A... 13:35:51 Magnet system MAIN current ramping to -0.0491 A... 13:35:55 Magnet system MAIN current ramping to 0.0417 A... 13:35:58 Magnet system MAIN current ramping to -0.0355 A... 13:36:02 Magnet system MAIN current ramping to 0.0301 A... 13:36:05 Magnet system MAIN current ramping to -0.0256 A... 13:36:08 Magnet system MAIN current ramping to 0.0218 A... 13:36:12 Magnet system MAIN current ramping to -0.0185 A... 13:36:15 Magnet system MAIN current ramping to 0.0157 A... 13:36:19 Magnet system MAIN current ramping to -0.0134 A... 13:36:22 Magnet system MAIN current ramping to 0.0114 A... 13:36:26 Magnet system MAIN current ramping to -0.0097 A... 13:36:29 Magnet system MAIN current ramping to 0.0082 A... 13:36:33 Magnet system MAIN current ramping to -0.0070 A... 13:36:36 Magnet system MAIN current ramping to 0.0000 A... 13:41:08 Magnet Current for MAIN, Imag = 0.0003 A Vtrans = 0.000112 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001011 A 13:41:09 Main (V) Voltage Measurement, V = 0.000050 V 13:41:13 Temperature Measurement, Probe Number = 0, T = 24.477000 C 13:41:13 Temperature Measurement, Probe Number = 1, T = 24.129000 C 13:41:14 Temperature Measurement, Probe Number = 2, T = 23.860000 C 13:41:15 Temperature Measurement, Probe Number = 3, T = 24.349000 C 13:41:15 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = Main (V), Value = 0.00 P2 = Coil_Top_Inside, Value = 24.48 P3 = Coil_Top_Outside, Value = 24.13 P4 = Core, Value = 23.86 P5 = Ambient, Value = 24.35 13:41:15 Magnetic Field Measurement Measuring the magnet strength... 13:41:15 Integrated Voltage Measurement... 13:41:16 Magnet Current for MAIN, Imag = 0.0003 A Vtrans = 0.000112 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001011 A 13:41:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000005430 Vs 13:41:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000004746 Vs 13:41:35 Magnet Current for MAIN, Imag = 0.0012 A Vtrans = 0.000187 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001011 A 13:41:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000004870 Vs 13:41:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000005051 Vs 13:41:54 Magnet Current for MAIN, Imag = 0.0008 A Vtrans = 0.000149 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001011 A 13:42:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000005128 Vs 13:42:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000005272 Vs 13:42:12 Magnet Current for MAIN, Imag = -0.0007 A Vtrans = 0.000025 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001011 A 13:42:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000004877 Vs 13:42:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000005317 Vs 13:42:29 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000000010 +- 0.000000211 Vs 13:42:29 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000000010 +- 0.000000211 Vs BL = 0.00000101 +- 0.00002112 Tm 13:42:33 Position moved: 0.000000 m 13:42:33 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00000 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00000 0.00002 0.00000 0.00000 13:42:33 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00000 0.00002 SL = 0.0000010 +- 0.0000211 Tm^2/m^n 13:42:33 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0000010 +- 0.0000211 Tm^2/m^n 13:42:36 Position moved: 0.000000 m 13:43:42 Magnet system MAIN current ramping to 14.5000 A... 13:43:53 Magnet system MAIN current ramping to -12.3250 A... 13:44:10 Magnet system MAIN current ramping to 10.4763 A... 13:44:25 Magnet system MAIN current ramping to -8.9048 A... 13:44:38 Magnet system MAIN current ramping to 7.5691 A... 13:44:49 Magnet system MAIN current ramping to -6.4337 A... 13:45:00 Magnet system MAIN current ramping to 5.4687 A... 13:45:09 Magnet system MAIN current ramping to -4.6484 A... 13:45:18 Magnet system MAIN current ramping to 3.9511 A... 13:45:25 Magnet system MAIN current ramping to -3.3584 A... 13:45:32 Magnet system MAIN current ramping to 2.8547 A... 13:45:39 Magnet system MAIN current ramping to -2.4265 A... 13:45:45 Magnet system MAIN current ramping to 2.0625 A... 13:45:51 Magnet system MAIN current ramping to -1.7531 A... 13:45:56 Magnet system MAIN current ramping to 1.4902 A... 13:46:01 Magnet system MAIN current ramping to -1.2666 A... 13:46:06 Magnet system MAIN current ramping to 1.0766 A... 13:46:11 Magnet system MAIN current ramping to -0.9151 A... 13:46:15 Magnet system MAIN current ramping to 0.7779 A... 13:46:19 Magnet system MAIN current ramping to -0.6612 A... 13:46:23 Magnet system MAIN current ramping to 0.5620 A... 13:46:27 Magnet system MAIN current ramping to -0.4777 A... 13:46:31 Magnet system MAIN current ramping to 0.4061 A... 13:46:35 Magnet system MAIN current ramping to -0.3452 A... 13:46:39 Magnet system MAIN current ramping to 0.2934 A... 13:46:43 Magnet system MAIN current ramping to -0.2494 A... 13:46:47 Magnet system MAIN current ramping to 0.2120 A... 13:46:50 Magnet system MAIN current ramping to -0.1802 A... 13:46:54 Magnet system MAIN current ramping to 0.1531 A... 13:46:57 Magnet system MAIN current ramping to -0.1302 A... 13:47:01 Magnet system MAIN current ramping to 0.1106 A... 13:47:05 Magnet system MAIN current ramping to -0.0940 A... 13:47:08 Magnet system MAIN current ramping to 0.0799 A... 13:47:12 Magnet system MAIN current ramping to -0.0679 A... 13:47:15 Magnet system MAIN current ramping to 0.0578 A... 13:47:19 Magnet system MAIN current ramping to -0.0491 A... 13:47:22 Magnet system MAIN current ramping to 0.0417 A... 13:47:26 Magnet system MAIN current ramping to -0.0355 A... 13:47:29 Magnet system MAIN current ramping to 0.0301 A... 13:47:32 Magnet system MAIN current ramping to -0.0256 A... 13:47:36 Magnet system MAIN current ramping to 0.0218 A... 13:47:39 Magnet system MAIN current ramping to -0.0185 A... 13:47:43 Magnet system MAIN current ramping to 0.0157 A... 13:47:46 Magnet system MAIN current ramping to -0.0134 A... 13:47:50 Magnet system MAIN current ramping to 0.0114 A... 13:47:53 Magnet system MAIN current ramping to -0.0097 A... 13:47:57 Magnet system MAIN current ramping to 0.0082 A... 13:48:00 Magnet system MAIN current ramping to -0.0070 A... 13:48:04 Magnet system MAIN current ramping to 0.0000 A... 13:49:43 Magnet Current for MAIN, Imag = 0.0002 A Vtrans = 0.000100 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001011 A 13:49:43 Main (V) Voltage Measurement, V = 0.000037 V 13:49:47 Temperature Measurement, Probe Number = 0, T = 24.603000 C 13:49:48 Temperature Measurement, Probe Number = 1, T = 24.245000 C 13:49:49 Temperature Measurement, Probe Number = 2, T = 23.960000 C 13:49:50 Temperature Measurement, Probe Number = 3, T = 24.472000 C 13:49:50 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = Main (V), Value = 0.00 P2 = Coil_Top_Inside, Value = 24.60 P3 = Coil_Top_Outside, Value = 24.25 P4 = Core, Value = 23.96 P5 = Ambient, Value = 24.47 13:49:50 Magnetic Field Measurement Measuring the magnet strength... 13:49:50 Integrated Voltage Measurement... 13:49:51 Magnet Current for MAIN, Imag = -0.0001 A Vtrans = 0.000075 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001011 A 13:50:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000005505 Vs 13:50:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000005713 Vs 13:50:10 Magnet Current for MAIN, Imag = 0.0011 A Vtrans = 0.000174 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001011 A 13:50:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000005411 Vs 13:50:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000005303 Vs 13:50:28 Magnet Current for MAIN, Imag = -0.0001 A Vtrans = 0.000075 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001011 A 13:50:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000005219 Vs 13:50:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000005443 Vs 13:50:46 Magnet Current for MAIN, Imag = 0.0012 A Vtrans = 0.000187 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001011 A 13:50:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000005202 Vs 13:51:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000005316 Vs 13:51:04 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000000055 +- 0.000000066 Vs 13:51:04 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000000055 +- 0.000000066 Vs BL = 0.00000548 +- 0.00000662 Tm 13:51:07 Position moved: 0.000000 m 13:51:07 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00001 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00001 0.00001 0.00001 0.00000 13:51:07 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00001 0.00001 SL = 0.0000055 +- 0.0000066 Tm^2/m^n 13:51:07 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0000055 +- 0.0000066 Tm^2/m^n 13:51:10 Position moved: 0.000000 m 13:51:13 Position moved: 0.000000 m 13:51:16 Magnet system MAIN current ramping to 0.0000 A...