SLAC Magnetic Measurements Date: 11-10-2025 Time: 14:59:43 Project: FACET-II Magnet Type: Dipole Magnet Name: 4595 Serial Number: 30822-4 Run Number: 13 Measurement Device: 1wire Operator: sda Comment: Degauss Currents f = 0.85 totals point = 49 Imax = 14.5. No offset correction, like run 5-11 Test Currents for MAIN (A): 14.50 -12.32 10.48 -8.90 7.57 -6.43 5.47 -4.65 3.95 -3.36 2.85 -2.43 2.06 -1.75 1.49 -1.27 1.08 -0.92 0.78 -0.66 0.56 -0.48 0.41 -0.35 0.29 -0.25 0.21 -0.18 0.15 -0.13 0.11 -0.09 0.08 -0.07 0.06 -0.05 0.04 -0.04 0.03 -0.03 0.02 -0.02 0.02 -0.01 0.01 -0.01 0.01 -0.01 0.00 Integrated Dipole Strength Distance the wire was to be moved = 0.010000 m Number of turns in the wire = 1 Number of measurements for averaging = 4 MAIN +/- sigma BL sigBL BL/I sigBL/I (A) (A) (Tm) (Tm) (Tm/A) (Tm/A) ------------+---------- -------------+------------ -------------+------------- 0.0003 0.0005 0.000012 0.000023 0.000000 0.000000