SLAC Magnetic Measurements Date: 11-10-2025 Time: 15:57:37 Project: FACET-II Magnet Type: Dipole Magnet Name: 4595 Serial Number: 30822-4 Run Number: 7 Measurement Device: 1wire Operator: sda Comment: Degauss Currents f = 0.87 totals point = 49 Imax = 14.5 Test Currents for MAIN (A): 14.50 -12.62 10.98 -9.55 8.31 -7.23 6.29 -5.47 4.76 -4.14 3.60 -3.13 2.73 -2.37 2.06 -1.80 1.56 -1.36 1.18 -1.03 0.89 -0.78 0.68 -0.59 0.51 -0.45 0.39 -0.34 0.29 -0.26 0.22 -0.19 0.17 -0.15 0.13 -0.11 0.10 -0.08 0.07 -0.06 0.06 -0.05 0.04 -0.04 0.03 -0.03 0.02 -0.02 0.00 15:58:02 Position moved: 0.000000 m 15:58:21 Magnet Current for MAIN, Imag = 0.0007 A Vtrans = 0.000062 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 15:58:22 Magnet Current for MAIN, Imag = 0.0012 A Vtrans = 0.000100 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 15:58:23 Magnet Current for MAIN, Imag = 0.0024 A Vtrans = 0.000199 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 15:58:24 Magnet Current for MAIN, Imag = 0.0012 A Vtrans = 0.000100 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 15:58:24 Magnet Avgerage Current Measurement for MAIN : Imag = 0.0014 +- 0.0006 A 15:58:39 Initial Zero Current Measurement for MAIN, Imag_zero = 0.001383 A 15:58:39 Ambient Measurement Device(s) Being Used, type = None 15:58:40 Magnet Voltage Measurement Device(s) Being Used, type = HP34970 15:58:41 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 15:58:41 Ambient Measurement Device(s) Being Used, type = None 15:58:43 Position moved: 0.000000 m 15:58:46 Magnet system MAIN current ramping to 14.5000 A... 15:58:57 Magnet system MAIN current ramping to -12.6150 A... 15:59:14 Magnet system MAIN current ramping to 10.9750 A... 15:59:29 Magnet system MAIN current ramping to -9.5483 A... 15:59:42 Magnet system MAIN current ramping to 8.3070 A... 15:59:55 Magnet system MAIN current ramping to -7.2271 A... 16:00:06 Magnet system MAIN current ramping to 6.2876 A... 16:00:16 Magnet system MAIN current ramping to -5.4702 A... 16:00:25 Magnet system MAIN current ramping to 4.7591 A... 16:00:34 Magnet system MAIN current ramping to -4.1404 A... 16:00:42 Magnet system MAIN current ramping to 3.6021 A... 16:00:49 Magnet system MAIN current ramping to -3.1339 A... 16:00:56 Magnet system MAIN current ramping to 2.7265 A... 16:01:02 Magnet system MAIN current ramping to -2.3720 A... 16:01:08 Magnet system MAIN current ramping to 2.0637 A... 16:01:14 Magnet system MAIN current ramping to -1.7954 A... 16:01:19 Magnet system MAIN current ramping to 1.5620 A... 16:01:25 Magnet system MAIN current ramping to -1.3589 A... 16:01:29 Magnet system MAIN current ramping to 1.1823 A... 16:01:34 Magnet system MAIN current ramping to -1.0286 A... 16:01:39 Magnet system MAIN current ramping to 0.8949 A... 16:01:43 Magnet system MAIN current ramping to -0.7785 A... 16:01:47 Magnet system MAIN current ramping to 0.6773 A... 16:01:51 Magnet system MAIN current ramping to -0.5893 A... 16:01:56 Magnet system MAIN current ramping to 0.5127 A... 16:02:00 Magnet system MAIN current ramping to -0.4460 A... 16:02:03 Magnet system MAIN current ramping to 0.3880 A... 16:02:07 Magnet system MAIN current ramping to -0.3376 A... 16:02:11 Magnet system MAIN current ramping to 0.2937 A... 16:02:15 Magnet system MAIN current ramping to -0.2555 A... 16:02:19 Magnet system MAIN current ramping to 0.2223 A... 16:02:22 Magnet system MAIN current ramping to -0.1934 A... 16:02:26 Magnet system MAIN current ramping to 0.1683 A... 16:02:30 Magnet system MAIN current ramping to -0.1464 A... 16:02:33 Magnet system MAIN current ramping to 0.1274 A... 16:02:37 Magnet system MAIN current ramping to -0.1108 A... 16:02:40 Magnet system MAIN current ramping to 0.0964 A... 16:02:44 Magnet system MAIN current ramping to -0.0839 A... 16:02:47 Magnet system MAIN current ramping to 0.0730 A... 16:02:51 Magnet system MAIN current ramping to -0.0635 A... 16:02:54 Magnet system MAIN current ramping to 0.0552 A... 16:02:58 Magnet system MAIN current ramping to -0.0481 A... 16:03:01 Magnet system MAIN current ramping to 0.0418 A... 16:03:05 Magnet system MAIN current ramping to -0.0364 A... 16:03:08 Magnet system MAIN current ramping to 0.0316 A... 16:03:12 Magnet system MAIN current ramping to -0.0275 A... 16:03:15 Magnet system MAIN current ramping to 0.0239 A... 16:03:19 Magnet system MAIN current ramping to -0.0208 A... 16:03:22 Magnet system MAIN current ramping to 0.0000 A... 16:04:40 Magnet Current for MAIN, Imag = 0.0003 A Vtrans = 0.000137 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001383 A 16:04:41 Main (V) Voltage Measurement, V = 0.000037 V 16:04:48 Temperature Measurement, Probe Number = 0, T = 25.522000 C 16:04:49 Temperature Measurement, Probe Number = 1, T = 24.889000 C 16:04:50 Temperature Measurement, Probe Number = 2, T = 24.689000 C 16:04:51 Temperature Measurement, Probe Number = 3, T = 24.854000 C 16:04:51 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = Main (V), Value = 0.00 P2 = Coil_Top_Inside, Value = 25.52 P3 = Coil_Top_Outside, Value = 24.89 P4 = Core, Value = 24.69 P5 = Ambient, Value = 24.85 16:04:51 Magnetic Field Measurement Measuring the magnet strength... 16:04:51 Integrated Voltage Measurement... 16:04:52 Magnet Current for MAIN, Imag = 0.0006 A Vtrans = 0.000162 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001383 A 16:05:02 Voltage Offset Correction: v_off_ini = -0.000002455 V, v_off_fin = -0.000002348 V 16:05:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000000074 Vs 16:05:11 Voltage Offset Correction: v_off_ini = -0.000002386 V, v_off_fin = -0.000002536 V 16:05:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000000049 Vs 16:05:12 Magnet Current for MAIN, Imag = 0.0017 A Vtrans = 0.000261 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001383 A 16:05:21 Voltage Offset Correction: v_off_ini = -0.000002443 V, v_off_fin = -0.000002459 V 16:05:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000000206 Vs 16:05:30 Voltage Offset Correction: v_off_ini = -0.000002443 V, v_off_fin = -0.000001888 V 16:05:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000000206 Vs 16:05:31 Magnet Current for MAIN, Imag = -0.0003 A Vtrans = 0.000087 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001383 A 16:05:40 Voltage Offset Correction: v_off_ini = -0.000002382 V, v_off_fin = -0.000002413 V 16:05:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000000329 Vs 16:05:49 Voltage Offset Correction: v_off_ini = -0.000002456 V, v_off_fin = -0.000002204 V 16:05:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000000150 Vs 16:05:50 Magnet Current for MAIN, Imag = -0.0002 A Vtrans = 0.000100 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001383 A 16:05:59 Voltage Offset Correction: v_off_ini = -0.000002446 V, v_off_fin = -0.000002240 V 16:05:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000000217 Vs 16:06:08 Voltage Offset Correction: v_off_ini = -0.000002332 V, v_off_fin = -0.000002332 V 16:06:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000000147 Vs 16:06:08 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000000172 +- 0.000000067 Vs 16:06:08 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000000172 +- 0.000000067 Vs BL = 0.00001723 +- 0.00000672 Tm 16:06:12 Position moved: 0.000000 m 16:06:12 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00002 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00002 0.00001 0.00002 0.00000 16:06:12 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00002 0.00001 SL = 0.0000172 +- 0.0000067 Tm^2/m^n 16:06:12 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0000172 +- 0.0000067 Tm^2/m^n 16:06:15 Position moved: 0.000000 m 16:06:57 Magnet system MAIN current ramping to 14.5000 A... 16:07:08 Magnet system MAIN current ramping to -12.6150 A... 16:07:25 Magnet system MAIN current ramping to 10.9750 A... 16:07:40 Magnet system MAIN current ramping to -9.5483 A... 16:07:54 Magnet system MAIN current ramping to 8.3070 A... 16:08:06 Magnet system MAIN current ramping to -7.2271 A... 16:08:17 Magnet system MAIN current ramping to 6.2876 A... 16:08:28 Magnet system MAIN current ramping to -5.4702 A... 16:08:37 Magnet system MAIN current ramping to 4.7591 A... 16:08:46 Magnet system MAIN current ramping to -4.1404 A... 16:08:53 Magnet system MAIN current ramping to 3.6021 A... 16:09:01 Magnet system MAIN current ramping to -3.1339 A... 16:09:07 Magnet system MAIN current ramping to 2.7265 A... 16:09:14 Magnet system MAIN current ramping to -2.3720 A... 16:09:20 Magnet system MAIN current ramping to 2.0637 A... 16:09:25 Magnet system MAIN current ramping to -1.7954 A... 16:09:31 Magnet system MAIN current ramping to 1.5620 A... 16:09:36 Magnet system MAIN current ramping to -1.3589 A... 16:09:41 Magnet system MAIN current ramping to 1.1823 A... 16:09:45 Magnet system MAIN current ramping to -1.0286 A... 16:09:50 Magnet system MAIN current ramping to 0.8949 A... 16:09:54 Magnet system MAIN current ramping to -0.7785 A... 16:09:59 Magnet system MAIN current ramping to 0.6773 A... 16:10:03 Magnet system MAIN current ramping to -0.5893 A... 16:10:07 Magnet system MAIN current ramping to 0.5127 A... 16:10:11 Magnet system MAIN current ramping to -0.4460 A... 16:10:15 Magnet system MAIN current ramping to 0.3880 A... 16:10:19 Magnet system MAIN current ramping to -0.3376 A... 16:10:22 Magnet system MAIN current ramping to 0.2937 A... 16:10:26 Magnet system MAIN current ramping to -0.2555 A... 16:10:30 Magnet system MAIN current ramping to 0.2223 A... 16:10:34 Magnet system MAIN current ramping to -0.1934 A... 16:10:37 Magnet system MAIN current ramping to 0.1683 A... 16:10:41 Magnet system MAIN current ramping to -0.1464 A... 16:10:44 Magnet system MAIN current ramping to 0.1274 A... 16:10:48 Magnet system MAIN current ramping to -0.1108 A... 16:10:52 Magnet system MAIN current ramping to 0.0964 A... 16:10:55 Magnet system MAIN current ramping to -0.0839 A... 16:10:59 Magnet system MAIN current ramping to 0.0730 A... 16:11:02 Magnet system MAIN current ramping to -0.0635 A... 16:11:06 Magnet system MAIN current ramping to 0.0552 A... 16:11:09 Magnet system MAIN current ramping to -0.0481 A... 16:11:12 Magnet system MAIN current ramping to 0.0418 A... 16:11:16 Magnet system MAIN current ramping to -0.0364 A... 16:11:19 Magnet system MAIN current ramping to 0.0316 A... 16:11:23 Magnet system MAIN current ramping to -0.0275 A... 16:11:26 Magnet system MAIN current ramping to 0.0239 A... 16:11:30 Magnet system MAIN current ramping to -0.0208 A... 16:11:33 Magnet system MAIN current ramping to 0.0000 A... 16:13:07 Magnet Current for MAIN, Imag = -0.0003 A Vtrans = 0.000087 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001383 A 16:13:08 Main (V) Voltage Measurement, V = 0.000025 V 16:13:12 Temperature Measurement, Probe Number = 0, T = 25.520000 C 16:13:13 Temperature Measurement, Probe Number = 1, T = 24.890000 C 16:13:13 Temperature Measurement, Probe Number = 2, T = 24.685000 C 16:13:14 Temperature Measurement, Probe Number = 3, T = 24.797000 C 16:13:14 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = 0.00 P2 = Coil_Top_Inside, Value = 25.52 P3 = Coil_Top_Outside, Value = 24.89 P4 = Core, Value = 24.68 P5 = Ambient, Value = 24.80 16:13:14 Magnetic Field Measurement Measuring the magnet strength... 16:13:14 Integrated Voltage Measurement... 16:13:15 Magnet Current for MAIN, Imag = -0.0002 A Vtrans = 0.000100 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001383 A 16:13:25 Voltage Offset Correction: v_off_ini = -0.000002405 V, v_off_fin = -0.000002732 V 16:13:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000000126 Vs 16:13:34 Voltage Offset Correction: v_off_ini = -0.000002352 V, v_off_fin = -0.000002117 V 16:13:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000000491 Vs 16:13:35 Magnet Current for MAIN, Imag = 0.0004 A Vtrans = 0.000149 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001383 A 16:13:44 Voltage Offset Correction: v_off_ini = -0.000002310 V, v_off_fin = -0.000002521 V 16:13:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000000177 Vs 16:13:53 Voltage Offset Correction: v_off_ini = -0.000002258 V, v_off_fin = -0.000001953 V 16:13:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000000105 Vs 16:13:54 Magnet Current for MAIN, Imag = -0.0002 A Vtrans = 0.000100 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001383 A 16:14:03 Voltage Offset Correction: v_off_ini = -0.000002236 V, v_off_fin = -0.000002117 V 16:14:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000000483 Vs 16:14:12 Voltage Offset Correction: v_off_ini = -0.000002298 V, v_off_fin = -0.000002321 V 16:14:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000000150 Vs 16:14:13 Magnet Current for MAIN, Imag = 0.0006 A Vtrans = 0.000162 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001383 A 16:14:22 Voltage Offset Correction: v_off_ini = -0.000002221 V, v_off_fin = -0.000002535 V 16:14:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000000509 Vs 16:14:31 Voltage Offset Correction: v_off_ini = -0.000002404 V, v_off_fin = -0.000002536 V 16:14:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000000209 Vs 16:14:31 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000000250 +- 0.000000091 Vs 16:14:31 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000000250 +- 0.000000091 Vs BL = 0.00002496 +- 0.00000905 Tm 16:14:35 Position moved: 0.000000 m 16:14:35 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00002 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00002 0.00001 0.00002 0.00000 16:14:35 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00002 0.00001 SL = 0.0000250 +- 0.0000091 Tm^2/m^n 16:14:35 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0000250 +- 0.0000091 Tm^2/m^n 16:14:38 Position moved: 0.000000 m 16:15:03 Magnet system MAIN current ramping to 14.5000 A... 16:15:13 Magnet system MAIN current ramping to -12.6150 A... 16:15:30 Magnet system MAIN current ramping to 10.9750 A... 16:15:45 Magnet system MAIN current ramping to -9.5483 A... 16:15:59 Magnet system MAIN current ramping to 8.3070 A... 16:16:11 Magnet system MAIN current ramping to -7.2271 A... 16:16:23 Magnet system MAIN current ramping to 6.2876 A... 16:16:33 Magnet system MAIN current ramping to -5.4702 A... 16:16:42 Magnet system MAIN current ramping to 4.7591 A... 16:16:51 Magnet system MAIN current ramping to -4.1404 A... 16:16:59 Magnet system MAIN current ramping to 3.6021 A... 16:17:06 Magnet system MAIN current ramping to -3.1339 A... 16:17:13 Magnet system MAIN current ramping to 2.7265 A... 16:17:19 Magnet system MAIN current ramping to -2.3720 A... 16:17:25 Magnet system MAIN current ramping to 2.0637 A... 16:17:31 Magnet system MAIN current ramping to -1.7954 A... 16:17:36 Magnet system MAIN current ramping to 1.5620 A... 16:17:41 Magnet system MAIN current ramping to -1.3589 A... 16:17:46 Magnet system MAIN current ramping to 1.1823 A... 16:17:51 Magnet system MAIN current ramping to -1.0286 A... 16:17:55 Magnet system MAIN current ramping to 0.8949 A... 16:18:00 Magnet system MAIN current ramping to -0.7785 A... 16:18:04 Magnet system MAIN current ramping to 0.6773 A... 16:18:08 Magnet system MAIN current ramping to -0.5893 A... 16:18:12 Magnet system MAIN current ramping to 0.5127 A... 16:18:16 Magnet system MAIN current ramping to -0.4460 A... 16:18:20 Magnet system MAIN current ramping to 0.3880 A... 16:18:24 Magnet system MAIN current ramping to -0.3376 A... 16:18:28 Magnet system MAIN current ramping to 0.2937 A... 16:18:32 Magnet system MAIN current ramping to -0.2555 A... 16:18:35 Magnet system MAIN current ramping to 0.2223 A... 16:18:39 Magnet system MAIN current ramping to -0.1934 A... 16:18:43 Magnet system MAIN current ramping to 0.1683 A... 16:18:46 Magnet system MAIN current ramping to -0.1464 A... 16:18:50 Magnet system MAIN current ramping to 0.1274 A... 16:18:53 Magnet system MAIN current ramping to -0.1108 A... 16:18:57 Magnet system MAIN current ramping to 0.0964 A... 16:19:00 Magnet system MAIN current ramping to -0.0839 A... 16:19:04 Magnet system MAIN current ramping to 0.0730 A... 16:19:07 Magnet system MAIN current ramping to -0.0635 A... 16:19:11 Magnet system MAIN current ramping to 0.0552 A... 16:19:14 Magnet system MAIN current ramping to -0.0481 A... 16:19:18 Magnet system MAIN current ramping to 0.0418 A... 16:19:21 Magnet system MAIN current ramping to -0.0364 A... 16:19:25 Magnet system MAIN current ramping to 0.0316 A... 16:19:28 Magnet system MAIN current ramping to -0.0275 A... 16:19:32 Magnet system MAIN current ramping to 0.0239 A... 16:19:35 Magnet system MAIN current ramping to -0.0208 A... 16:19:39 Magnet system MAIN current ramping to 0.0000 A... 16:21:40 Magnet Current for MAIN, Imag = 0.0006 A Vtrans = 0.000162 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001383 A 16:21:41 Main (V) Voltage Measurement, V = 0.000025 V 16:21:45 Temperature Measurement, Probe Number = 0, T = 25.576000 C 16:21:46 Temperature Measurement, Probe Number = 1, T = 24.909000 C 16:21:47 Temperature Measurement, Probe Number = 2, T = 24.689000 C 16:21:47 Temperature Measurement, Probe Number = 3, T = 24.830000 C 16:21:47 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = Main (V), Value = 0.00 P2 = Coil_Top_Inside, Value = 25.58 P3 = Coil_Top_Outside, Value = 24.91 P4 = Core, Value = 24.69 P5 = Ambient, Value = 24.83 16:23:39 Magnetic Field Measurement Measuring the magnet strength... 16:23:39 Integrated Voltage Measurement... 16:23:40 Magnet Current for MAIN, Imag = -0.0005 A Vtrans = 0.000075 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001383 A 16:23:50 Voltage Offset Correction: v_off_ini = -0.000002555 V, v_off_fin = -0.000002500 V 16:23:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000000256 Vs 16:23:59 Voltage Offset Correction: v_off_ini = -0.000002210 V, v_off_fin = -0.000003084 V 16:23:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000000093 Vs 16:24:00 Magnet Current for MAIN, Imag = -0.0002 A Vtrans = 0.000100 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001383 A 16:24:09 Voltage Offset Correction: v_off_ini = -0.000002545 V, v_off_fin = -0.000002623 V 16:24:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000000154 Vs 16:24:18 Voltage Offset Correction: v_off_ini = -0.000002424 V, v_off_fin = -0.000002682 V 16:24:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000000293 Vs 16:24:19 Magnet Current for MAIN, Imag = 0.0004 A Vtrans = 0.000149 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001383 A 16:24:28 Voltage Offset Correction: v_off_ini = -0.000002407 V, v_off_fin = -0.000002175 V 16:24:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000000233 Vs 16:24:37 Voltage Offset Correction: v_off_ini = -0.000002692 V, v_off_fin = -0.000002709 V 16:24:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000000300 Vs 16:24:38 Magnet Current for MAIN, Imag = 0.0012 A Vtrans = 0.000212 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001383 A 16:24:47 Voltage Offset Correction: v_off_ini = -0.000002382 V, v_off_fin = -0.000002711 V 16:24:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000000020 Vs 16:24:56 Voltage Offset Correction: v_off_ini = -0.000002384 V, v_off_fin = -0.000002735 V 16:24:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000000420 Vs 16:24:56 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000000216 +- 0.000000034 Vs 16:24:56 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000000216 +- 0.000000034 Vs BL = 0.00002160 +- 0.00000339 Tm 16:25:00 Position moved: 0.000000 m 16:25:00 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00002 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00002 0.00000 0.00002 0.00000 16:25:00 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00002 0.00000 SL = 0.0000216 +- 0.0000034 Tm^2/m^n 16:25:00 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0000216 +- 0.0000034 Tm^2/m^n 16:25:03 Position moved: 0.000000 m 16:25:26 Position moved: 0.000000 m 16:25:29 Magnet system MAIN current ramping to 0.0000 A...