SLAC Magnetic Measurements Date: 02-04-2005 Time: 09:11:32 Project: E163 Magnet Type: quad Magnet Name: QE-N1 Serial Number: Run Number: 2 Measurement Device: 10 wire Operator: sa Comment: Repeat wire meas for coil calibration Standardization: 5 cycles from 0.0 A to 120.0 A to 0.0 A Test Currents (A): 100.0 100.0 100.0 120.0 120.0 120.0 09:11:40 Initial Zero Current Measurement, Imag_zero = 0.0000 A 09:11:40 Magnet current ramping to 120.0000 A... 09:13:19 Magnet current ramping to 0.0000 A... 09:14:59 Magnet current ramping to 120.0000 A... 09:16:38 Magnet current ramping to 0.0000 A... 09:18:18 Magnet current ramping to 120.0000 A... 09:19:57 Magnet current ramping to 0.0000 A... 09:21:37 Magnet current ramping to 120.0000 A... 09:23:16 Magnet current ramping to 0.0000 A... 09:24:56 Magnet current ramping to 120.0000 A... 09:26:35 Magnet current ramping to 0.0000 A... 09:28:15 Magnet current ramping to 100.0000 A... 09:29:44 Magnet Current, Imag = 100.0110 A Vtrans = 8.000880 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:29:46 Magnet Current, Imag = 100.0102 A Vtrans = 8.000820 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:29:47 Magnet Current, Imag = 100.0097 A Vtrans = 8.000780 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:29:49 Magnet Current, Imag = 100.0088 A Vtrans = 8.000700 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:29:49 Magnet Current Measurement: Imag = 100.0099 +- 0.0008 A 09:29:49 Magnetic Field Measurement Measuring the magnet strength... 09:29:49 Integrated Voltage Measurement... 09:30:02 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.001092977 Vs 09:30:08 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.001049926 Vs 09:30:15 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.001090376 Vs 09:30:22 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.001052246 Vs 09:30:29 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.001089863 Vs 09:30:36 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.001053971 Vs 09:30:43 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.001088417 Vs 09:30:49 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.001051258 Vs 09:30:49 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.001071129 +- 0.000000779 Vs 09:30:49 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.001071129 +- 0.000000779 Vs BL = -0.02142258 +- 0.00001557 Tm 09:30:50 Integrated Voltage Measurement... 09:31:01 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.000544431 Vs 09:31:07 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.000506138 Vs 09:31:14 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.000542775 Vs 09:31:21 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.000508985 Vs 09:31:28 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.000539602 Vs 09:31:35 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.000510057 Vs 09:31:42 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.000539703 Vs 09:31:48 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.000509835 Vs 09:31:48 Integrated Voltage Average and RMS of Measurements X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.000525191 +- 0.000000445 Vs 09:31:48 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0050000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.000525191 +- 0.000000445 Vs BL = -0.01050382 +- 0.00000890 Tm 09:31:49 Integrated Voltage Measurement... 09:32:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = 0.000014936 Vs 09:32:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = -0.000045114 Vs 09:32:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = 0.000013075 Vs 09:32:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = -0.000046981 Vs 09:32:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = 0.000014153 Vs 09:32:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = -0.000043984 Vs 09:32:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = 0.000014496 Vs 09:32:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = -0.000045242 Vs 09:32:47 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0050000 m VT = 0.000029748 +- 0.000000397 Vs 09:32:47 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0050000 m, Nturns = 10.0 VT = 0.000029748 +- 0.000000397 Vs BL = 0.00059495 +- 0.00000795 Tm 09:32:48 Integrated Voltage Measurement... 09:32:59 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = 0.000569033 Vs 09:33:05 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = -0.000599661 Vs 09:33:12 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = 0.000568698 Vs 09:33:19 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = -0.000600106 Vs 09:33:26 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = 0.000568459 Vs 09:33:33 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = -0.000599700 Vs 09:33:40 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = 0.000568565 Vs 09:33:46 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = -0.000603423 Vs 09:33:46 Integrated Voltage Average and RMS of Measurements X0 = 0.0050000 m, Delta X = 0.0050000 m VT = 0.000584706 +- 0.000000754 Vs 09:33:46 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0050000 m, dx = 0.0050000 m, Nturns = 10.0 VT = 0.000584706 +- 0.000000754 Vs BL = 0.01169411 +- 0.00001508 Tm 09:33:46 Integrated Voltage Measurement... 09:33:58 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = 0.001111359 Vs 09:34:04 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = -0.001143882 Vs 09:34:11 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = 0.001112936 Vs 09:34:18 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = -0.001143669 Vs 09:34:25 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = 0.001115466 Vs 09:34:32 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = -0.001143144 Vs 09:34:38 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = 0.001113747 Vs 09:34:45 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = -0.001140859 Vs 09:34:45 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0050000 m VT = 0.001128133 +- 0.000000767 Vs 09:34:45 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0050000 m, Nturns = 10.0 VT = 0.001128133 +- 0.000000767 Vs BL = 0.02256265 +- 0.00001534 Tm 09:34:50 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00059 0.00001 1 2.20337 0.00094 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- -0.0100000 -0.02142 0.00002 -0.02145 0.00003 -0.0050000 -0.01050 0.00001 -0.01043 -0.00007 0.0000000 0.00059 0.00001 0.00059 0.00001 0.0050000 0.01169 0.00002 0.01160 0.00009 0.0100000 0.02256 0.00002 0.02262 -0.00006 09:34:51 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 5 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0100 -0.02142 0.00002 -0.0050 -0.01050 0.00001 0.0000 0.00059 0.00001 0.0050 0.01169 0.00002 0.0100 0.02256 0.00002 SL = 2.2033681 +- 0.0009419 Tm^2/m^n 09:34:51 Quadrupole Strength Calculation Check Slope = 2.203368 Tm/m, Inter = 0.000585 Tm, Sig_slope = 0.004846 Tm/m, Est_sig = 0.000077 Tm GL = 2.203368 +- 0.004846 T 09:34:51 Magnet Strength Measurement Harmonic Number = 2 SL = 2.2033681 +- 0.0009419 Tm^2/m^n 09:34:52 Magnet Current, Imag = 99.9862 A Vtrans = 7.998900 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:34:53 Magnet Current, Imag = 99.9860 A Vtrans = 7.998880 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:34:55 Magnet Current, Imag = 99.9861 A Vtrans = 7.998890 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:34:56 Magnet Current, Imag = 99.9857 A Vtrans = 7.998860 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:34:56 Magnet Current Measurement: Imag = 99.9860 +- 0.0002 A 09:34:56 Magnet current ramping to 100.0000 A... 09:35:29 Magnet Current, Imag = 99.9855 A Vtrans = 7.998840 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:35:30 Magnet Current, Imag = 99.9855 A Vtrans = 7.998840 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:35:31 Magnet Current, Imag = 99.9857 A Vtrans = 7.998860 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:35:33 Magnet Current, Imag = 99.9856 A Vtrans = 7.998850 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:35:33 Magnet Current Measurement: Imag = 99.9856 +- 0.0001 A 09:35:33 Magnetic Field Measurement Measuring the magnet strength... 09:35:33 Integrated Voltage Measurement... 09:35:46 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.001088023 Vs 09:35:53 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.001054824 Vs 09:36:00 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.001087886 Vs 09:36:06 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.001052071 Vs 09:36:13 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.001087498 Vs 09:36:20 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.001051540 Vs 09:36:27 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.001090162 Vs 09:36:34 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.001053571 Vs 09:36:34 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.001070697 +- 0.000000975 Vs 09:36:34 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.001070697 +- 0.000000975 Vs BL = -0.02141394 +- 0.00001949 Tm 09:36:34 Integrated Voltage Measurement... 09:36:45 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.000543814 Vs 09:36:52 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.000503071 Vs 09:36:59 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.000544928 Vs 09:37:05 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.000505673 Vs 09:37:12 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.000544540 Vs 09:37:19 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.000505603 Vs 09:37:26 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.000544817 Vs 09:37:33 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.000505545 Vs 09:37:33 Integrated Voltage Average and RMS of Measurements X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.000524749 +- 0.000000759 Vs 09:37:33 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0050000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.000524749 +- 0.000000759 Vs BL = -0.01049498 +- 0.00001517 Tm 09:37:33 Integrated Voltage Measurement... 09:37:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = 0.000009941 Vs 09:37:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = -0.000053355 Vs 09:37:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = 0.000006455 Vs 09:38:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = -0.000054116 Vs 09:38:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = 0.000002899 Vs 09:38:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = -0.000055595 Vs 09:38:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = 0.000003887 Vs 09:38:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = -0.000055127 Vs 09:38:32 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0050000 m VT = 0.000030172 +- 0.000000934 Vs 09:38:32 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0050000 m, Nturns = 10.0 VT = 0.000030172 +- 0.000000934 Vs BL = 0.00060344 +- 0.00001868 Tm 09:38:32 Integrated Voltage Measurement... 09:38:43 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = 0.000559001 Vs 09:38:50 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = -0.000610492 Vs 09:38:56 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = 0.000557531 Vs 09:39:03 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = -0.000611574 Vs 09:39:10 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = 0.000557032 Vs 09:39:17 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = -0.000610371 Vs 09:39:24 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = 0.000557409 Vs 09:39:31 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = -0.000612839 Vs 09:39:31 Integrated Voltage Average and RMS of Measurements X0 = 0.0050000 m, Delta X = 0.0050000 m VT = 0.000584531 +- 0.000000521 Vs 09:39:31 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0050000 m, dx = 0.0050000 m, Nturns = 10.0 VT = 0.000584531 +- 0.000000521 Vs BL = 0.01169062 +- 0.00001043 Tm 09:39:31 Integrated Voltage Measurement... 09:39:42 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = 0.001100444 Vs 09:39:49 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = -0.001154955 Vs 09:39:56 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = 0.001103447 Vs 09:40:02 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = -0.001152929 Vs 09:40:09 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = 0.001103200 Vs 09:40:16 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = -0.001154440 Vs 09:40:23 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = 0.001104645 Vs 09:40:30 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = -0.001155256 Vs 09:40:30 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0050000 m VT = 0.001128664 +- 0.000000842 Vs 09:40:30 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0050000 m, Nturns = 10.0 VT = 0.001128664 +- 0.000000842 Vs BL = 0.02257329 +- 0.00001684 Tm 09:40:35 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00059 0.00001 1 2.20320 0.00109 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- -0.0100000 -0.02141 0.00002 -0.02144 0.00003 -0.0050000 -0.01049 0.00002 -0.01042 -0.00007 0.0000000 0.00060 0.00002 0.00059 0.00001 0.0050000 0.01169 0.00001 0.01161 0.00008 0.0100000 0.02257 0.00002 0.02262 -0.00005 09:40:35 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 5 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0100 -0.02141 0.00002 -0.0050 -0.01049 0.00002 0.0000 0.00060 0.00002 0.0050 0.01169 0.00001 0.0100 0.02257 0.00002 SL = 2.2032011 +- 0.0010941 Tm^2/m^n 09:40:35 Quadrupole Strength Calculation Check Slope = 2.203201 Tm/m, Inter = 0.000592 Tm, Sig_slope = 0.004509 Tm/m, Est_sig = 0.000071 Tm GL = 2.203201 +- 0.004509 T 09:40:35 Magnet Strength Measurement Harmonic Number = 2 SL = 2.2032011 +- 0.0010941 Tm^2/m^n 09:40:36 Magnet Current, Imag = 99.9845 A Vtrans = 7.998760 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:40:38 Magnet Current, Imag = 99.9841 A Vtrans = 7.998730 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:40:39 Magnet Current, Imag = 99.9842 A Vtrans = 7.998740 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:40:40 Magnet Current, Imag = 99.9844 A Vtrans = 7.998750 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:40:40 Magnet Current Measurement: Imag = 99.9843 +- 0.0001 A 09:40:40 Magnet current ramping to 100.0000 A... 09:41:13 Magnet Current, Imag = 99.9841 A Vtrans = 7.998730 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:41:15 Magnet Current, Imag = 99.9837 A Vtrans = 7.998700 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:41:16 Magnet Current, Imag = 99.9841 A Vtrans = 7.998730 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:41:17 Magnet Current, Imag = 99.9842 A Vtrans = 7.998740 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:41:17 Magnet Current Measurement: Imag = 99.9841 +- 0.0002 A 09:41:17 Magnetic Field Measurement Measuring the magnet strength... 09:41:17 Integrated Voltage Measurement... 09:41:30 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.001095091 Vs 09:41:37 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.001048126 Vs 09:41:44 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.001095808 Vs 09:41:51 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.001044941 Vs 09:41:58 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.001094207 Vs 09:42:04 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.001047091 Vs 09:42:11 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.001094137 Vs 09:42:18 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.001046272 Vs 09:42:18 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.001070709 +- 0.000000543 Vs 09:42:18 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.001070709 +- 0.000000543 Vs BL = -0.02141418 +- 0.00001086 Tm 09:42:18 Integrated Voltage Measurement... 09:42:29 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.000547017 Vs 09:42:36 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.000504145 Vs 09:42:43 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.000545115 Vs 09:42:50 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.000504547 Vs 09:42:57 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.000544637 Vs 09:43:03 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.000503838 Vs 09:43:10 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.000544536 Vs 09:43:17 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.000505009 Vs 09:43:17 Integrated Voltage Average and RMS of Measurements X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.000524856 +- 0.000000478 Vs 09:43:17 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0050000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.000524856 +- 0.000000478 Vs BL = -0.01049711 +- 0.00000957 Tm 09:43:17 Integrated Voltage Measurement... 09:43:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = 0.000009327 Vs 09:43:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = -0.000049410 Vs 09:43:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = 0.000010252 Vs 09:43:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = -0.000051183 Vs 09:43:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = 0.000008075 Vs 09:44:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = -0.000053330 Vs 09:44:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = 0.000006436 Vs 09:44:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = -0.000053121 Vs 09:44:16 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0050000 m VT = 0.000030142 +- 0.000000587 Vs 09:44:16 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0050000 m, Nturns = 10.0 VT = 0.000030142 +- 0.000000587 Vs BL = 0.00060284 +- 0.00001173 Tm 09:44:16 Integrated Voltage Measurement... 09:44:27 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = 0.000561766 Vs 09:44:34 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = -0.000606258 Vs 09:44:41 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = 0.000559766 Vs 09:44:48 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = -0.000607447 Vs 09:44:55 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = 0.000560522 Vs 09:45:02 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = -0.000605813 Vs 09:45:08 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = 0.000561491 Vs 09:45:15 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = -0.000606218 Vs 09:45:15 Integrated Voltage Average and RMS of Measurements X0 = 0.0050000 m, Delta X = 0.0050000 m VT = 0.000583660 +- 0.000000319 Vs 09:45:15 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0050000 m, dx = 0.0050000 m, Nturns = 10.0 VT = 0.000583660 +- 0.000000319 Vs BL = 0.01167320 +- 0.00000638 Tm 09:45:15 Integrated Voltage Measurement... 09:45:26 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = 0.001108595 Vs 09:45:33 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = -0.001150871 Vs 09:45:40 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = 0.001108077 Vs 09:45:47 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = -0.001149873 Vs 09:45:54 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = 0.001108498 Vs 09:46:01 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = -0.001148883 Vs 09:46:07 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = 0.001111475 Vs 09:46:14 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = -0.001148072 Vs 09:46:14 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0050000 m VT = 0.001129293 +- 0.000000471 Vs 09:46:14 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0050000 m, Nturns = 10.0 VT = 0.001129293 +- 0.000000471 Vs BL = 0.02258586 +- 0.00000943 Tm 09:46:19 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00059 0.00000 1 2.20341 0.00062 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- -0.0100000 -0.02141 0.00001 -0.02144 0.00003 -0.0050000 -0.01050 0.00001 -0.01043 -0.00007 0.0000000 0.00060 0.00001 0.00059 0.00001 0.0050000 0.01167 0.00001 0.01161 0.00007 0.0100000 0.02259 0.00001 0.02262 -0.00004 09:46:20 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 5 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0100 -0.02141 0.00001 -0.0050 -0.01050 0.00001 0.0000 0.00060 0.00001 0.0050 0.01167 0.00001 0.0100 0.02259 0.00001 SL = 2.2034078 +- 0.0006195 Tm^2/m^n 09:46:20 Quadrupole Strength Calculation Check Slope = 2.203408 Tm/m, Inter = 0.000590 Tm, Sig_slope = 0.003968 Tm/m, Est_sig = 0.000063 Tm GL = 2.203408 +- 0.003968 T 09:46:20 Magnet Strength Measurement Harmonic Number = 2 SL = 2.2034078 +- 0.0006195 Tm^2/m^n 09:46:21 Magnet Current, Imag = 99.9830 A Vtrans = 7.998640 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:46:22 Magnet Current, Imag = 99.9831 A Vtrans = 7.998650 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:46:24 Magnet Current, Imag = 99.9832 A Vtrans = 7.998660 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:46:25 Magnet Current, Imag = 99.9834 A Vtrans = 7.998670 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:46:25 Magnet Current Measurement: Imag = 99.9832 +- 0.0001 A 09:46:25 Magnet current ramping to 120.0000 A... 09:47:09 Magnet Current, Imag = 120.0012 A Vtrans = 9.600100 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:47:11 Magnet Current, Imag = 120.0005 A Vtrans = 9.600040 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:47:12 Magnet Current, Imag = 120.0001 A Vtrans = 9.600010 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:47:13 Magnet Current, Imag = 119.9991 A Vtrans = 9.599930 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:47:13 Magnet Current Measurement: Imag = 120.0002 +- 0.0008 A 09:47:13 Magnetic Field Measurement Measuring the magnet strength... 09:47:13 Integrated Voltage Measurement... 09:47:26 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.001306934 Vs 09:47:33 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.001262865 Vs 09:47:40 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.001305024 Vs 09:47:47 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.001264459 Vs 09:47:54 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.001305268 Vs 09:48:01 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.001266610 Vs 09:48:07 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.001305018 Vs 09:48:14 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.001265667 Vs 09:48:14 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.001285231 +- 0.000000464 Vs 09:48:14 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.001285231 +- 0.000000464 Vs BL = -0.02570461 +- 0.00000929 Tm 09:48:14 Integrated Voltage Measurement... 09:48:26 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.000653605 Vs 09:48:32 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.000609432 Vs 09:48:39 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.000650065 Vs 09:48:46 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.000608480 Vs 09:48:53 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.000650715 Vs 09:49:00 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.000609611 Vs 09:49:07 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.000650954 Vs 09:49:13 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.000608787 Vs 09:49:13 Integrated Voltage Average and RMS of Measurements X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.000630206 +- 0.000000823 Vs 09:49:13 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0050000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.000630206 +- 0.000000823 Vs BL = -0.01260412 +- 0.00001646 Tm 09:49:13 Integrated Voltage Measurement... 09:49:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = 0.000016204 Vs 09:49:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = -0.000054867 Vs 09:49:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = 0.000015506 Vs 09:49:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = -0.000053645 Vs 09:49:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = 0.000016653 Vs 09:49:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = -0.000056729 Vs 09:50:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = 0.000016250 Vs 09:50:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = -0.000054311 Vs 09:50:12 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0050000 m VT = 0.000035521 +- 0.000000762 Vs 09:50:13 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0050000 m, Nturns = 10.0 VT = 0.000035521 +- 0.000000762 Vs BL = 0.00071041 +- 0.00001523 Tm 09:50:13 Integrated Voltage Measurement... 09:50:24 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = 0.000680888 Vs 09:50:31 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = -0.000717195 Vs 09:50:37 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = 0.000682591 Vs 09:50:44 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = -0.000717393 Vs 09:50:51 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = 0.000681741 Vs 09:50:58 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = -0.000716191 Vs 09:51:05 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = 0.000681827 Vs 09:51:12 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = -0.000719512 Vs 09:51:12 Integrated Voltage Average and RMS of Measurements X0 = 0.0050000 m, Delta X = 0.0050000 m VT = 0.000699667 +- 0.000000706 Vs 09:51:12 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0050000 m, dx = 0.0050000 m, Nturns = 10.0 VT = 0.000699667 +- 0.000000706 Vs BL = 0.01399335 +- 0.00001412 Tm 09:51:12 Integrated Voltage Measurement... 09:51:23 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = 0.001334041 Vs 09:51:30 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = -0.001372682 Vs 09:51:37 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = 0.001335905 Vs 09:51:43 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = -0.001374190 Vs 09:51:50 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = 0.001335029 Vs 09:51:57 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = -0.001371614 Vs 09:52:04 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = 0.001333095 Vs 09:52:11 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = -0.001372210 Vs 09:52:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0050000 m VT = 0.001353596 +- 0.000000884 Vs 09:52:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0050000 m, Nturns = 10.0 VT = 0.001353596 +- 0.000000884 Vs BL = 0.02707191 +- 0.00001769 Tm 09:52:16 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00069 0.00001 1 2.64301 0.00091 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- -0.0100000 -0.02570 0.00001 -0.02574 0.00003 -0.0050000 -0.01260 0.00002 -0.01252 -0.00008 0.0000000 0.00071 0.00002 0.00069 0.00002 0.0050000 0.01399 0.00001 0.01391 0.00008 0.0100000 0.02707 0.00002 0.02712 -0.00005 09:52:16 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 5 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0100 -0.02570 0.00001 -0.0050 -0.01260 0.00002 0.0000 0.00071 0.00002 0.0050 0.01399 0.00001 0.0100 0.02707 0.00002 SL = 2.6430105 +- 0.0009091 Tm^2/m^n 09:52:16 Quadrupole Strength Calculation Check Slope = 2.643010 Tm/m, Inter = 0.000693 Tm, Sig_slope = 0.004897 Tm/m, Est_sig = 0.000077 Tm GL = 2.643010 +- 0.004897 T 09:52:16 Magnet Strength Measurement Harmonic Number = 2 SL = 2.6430105 +- 0.0009091 Tm^2/m^n 09:52:17 Magnet Current, Imag = 119.9775 A Vtrans = 9.598200 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:52:19 Magnet Current, Imag = 119.9777 A Vtrans = 9.598220 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:52:20 Magnet Current, Imag = 119.9772 A Vtrans = 9.598180 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:52:22 Magnet Current, Imag = 119.9774 A Vtrans = 9.598190 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:52:22 Magnet Current Measurement: Imag = 119.9775 +- 0.0002 A 09:52:22 Magnet current ramping to 120.0000 A... 09:52:54 Magnet Current, Imag = 119.9775 A Vtrans = 9.598200 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:52:56 Magnet Current, Imag = 119.9772 A Vtrans = 9.598180 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:52:57 Magnet Current, Imag = 119.9771 A Vtrans = 9.598170 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:52:58 Magnet Current, Imag = 119.9770 A Vtrans = 9.598160 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:52:58 Magnet Current Measurement: Imag = 119.9772 +- 0.0002 A 09:52:58 Magnetic Field Measurement Measuring the magnet strength... 09:52:58 Integrated Voltage Measurement... 09:53:11 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.001303987 Vs 09:53:18 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.001267068 Vs 09:53:25 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.001302493 Vs 09:53:32 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.001264248 Vs 09:53:39 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.001304217 Vs 09:53:46 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.001265037 Vs 09:53:52 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.001302851 Vs 09:53:59 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.001265798 Vs 09:53:59 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.001284462 +- 0.000000770 Vs 09:53:59 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.001284462 +- 0.000000770 Vs BL = -0.02568925 +- 0.00001540 Tm 09:53:59 Integrated Voltage Measurement... 09:54:10 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.000649610 Vs 09:54:17 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.000609570 Vs 09:54:24 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.000648494 Vs 09:54:31 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.000606079 Vs 09:54:38 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.000650613 Vs 09:54:44 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.000608962 Vs 09:54:51 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.000650185 Vs 09:54:58 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.000609136 Vs 09:54:58 Integrated Voltage Average and RMS of Measurements X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.000629081 +- 0.000001038 Vs 09:54:58 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0050000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.000629081 +- 0.000001038 Vs BL = -0.01258163 +- 0.00002077 Tm 09:54:58 Integrated Voltage Measurement... 09:55:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = 0.000014334 Vs 09:55:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = -0.000055022 Vs 09:55:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = 0.000018554 Vs 09:55:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = -0.000054938 Vs 09:55:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = 0.000016408 Vs 09:55:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = -0.000058195 Vs 09:55:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = 0.000012589 Vs 09:55:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = -0.000057508 Vs 09:55:57 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0050000 m VT = 0.000035943 +- 0.000001106 Vs 09:55:57 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0050000 m, Nturns = 10.0 VT = 0.000035943 +- 0.000001106 Vs BL = 0.00071886 +- 0.00002212 Tm 09:55:57 Integrated Voltage Measurement... 09:56:08 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = 0.000680386 Vs 09:56:15 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = -0.000718590 Vs 09:56:22 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = 0.000681954 Vs 09:56:29 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = -0.000717492 Vs 09:56:36 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = 0.000680475 Vs 09:56:42 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = -0.000716682 Vs 09:56:49 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = 0.000681606 Vs 09:56:56 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = -0.000717016 Vs 09:56:56 Integrated Voltage Average and RMS of Measurements X0 = 0.0050000 m, Delta X = 0.0050000 m VT = 0.000699275 +- 0.000000428 Vs 09:56:56 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0050000 m, dx = 0.0050000 m, Nturns = 10.0 VT = 0.000699275 +- 0.000000428 Vs BL = 0.01398550 +- 0.00000856 Tm 09:56:56 Integrated Voltage Measurement... 09:57:07 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = 0.001335281 Vs 09:57:14 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = -0.001369972 Vs 09:57:21 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = 0.001337861 Vs 09:57:28 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = -0.001368150 Vs 09:57:35 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = 0.001339502 Vs 09:57:41 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = -0.001370034 Vs 09:57:48 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = 0.001338901 Vs 09:57:55 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = -0.001369832 Vs 09:57:55 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0050000 m VT = 0.001353692 +- 0.000000897 Vs 09:57:55 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0050000 m, Nturns = 10.0 VT = 0.001353692 +- 0.000000897 Vs BL = 0.02707383 +- 0.00001794 Tm 09:58:00 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00070 0.00001 1 2.64187 0.00105 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- -0.0100000 -0.02569 0.00002 -0.02572 0.00003 -0.0050000 -0.01258 0.00002 -0.01251 -0.00007 0.0000000 0.00072 0.00002 0.00070 0.00002 0.0050000 0.01399 0.00001 0.01391 0.00007 0.0100000 0.02707 0.00002 0.02712 -0.00005 09:58:00 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 5 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0100 -0.02569 0.00002 -0.0050 -0.01258 0.00002 0.0000 0.00072 0.00002 0.0050 0.01399 0.00001 0.0100 0.02707 0.00002 SL = 2.6418657 +- 0.0010471 Tm^2/m^n 09:58:00 Quadrupole Strength Calculation Check Slope = 2.641866 Tm/m, Inter = 0.000701 Tm, Sig_slope = 0.004359 Tm/m, Est_sig = 0.000069 Tm GL = 2.641866 +- 0.004359 T 09:58:00 Magnet Strength Measurement Harmonic Number = 2 SL = 2.6418657 +- 0.0010471 Tm^2/m^n 09:58:02 Magnet Current, Imag = 119.9751 A Vtrans = 9.598010 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:58:03 Magnet Current, Imag = 119.9753 A Vtrans = 9.598020 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:58:04 Magnet Current, Imag = 119.9750 A Vtrans = 9.598000 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:58:06 Magnet Current, Imag = 119.9750 A Vtrans = 9.598000 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:58:06 Magnet Current Measurement: Imag = 119.9751 +- 0.0001 A 09:58:06 Magnet current ramping to 120.0000 A... 09:58:39 Magnet Current, Imag = 119.9756 A Vtrans = 9.598050 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:58:40 Magnet Current, Imag = 119.9758 A Vtrans = 9.598060 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:58:41 Magnet Current, Imag = 119.9756 A Vtrans = 9.598050 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:58:43 Magnet Current, Imag = 119.9748 A Vtrans = 9.597980 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 09:58:43 Magnet Current Measurement: Imag = 119.9754 +- 0.0004 A 09:58:43 Magnetic Field Measurement Measuring the magnet strength... 09:58:43 Integrated Voltage Measurement... 09:58:56 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.001298256 Vs 09:59:03 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.001273049 Vs 09:59:09 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.001298382 Vs 09:59:16 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.001271297 Vs 09:59:23 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.001297439 Vs 09:59:30 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.001273116 Vs 09:59:37 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.001296545 Vs 09:59:43 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.001269203 Vs 09:59:43 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.001284661 +- 0.000001071 Vs 09:59:44 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.001284661 +- 0.000001071 Vs BL = -0.02569322 +- 0.00002142 Tm 09:59:44 Integrated Voltage Measurement... 09:59:55 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.000645128 Vs 10:00:02 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.000613567 Vs 10:00:08 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.000646185 Vs 10:00:15 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.000613342 Vs 10:00:22 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.000647222 Vs 10:00:29 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.000612430 Vs 10:00:36 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.000644056 Vs 10:00:42 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.000613184 Vs 10:00:43 Integrated Voltage Average and RMS of Measurements X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.000629389 +- 0.000000481 Vs 10:00:43 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0050000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.000629389 +- 0.000000481 Vs BL = -0.01258779 +- 0.00000961 Tm 10:00:43 Integrated Voltage Measurement... 10:00:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = 0.000020828 Vs 10:01:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = -0.000051965 Vs 10:01:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = 0.000019746 Vs 10:01:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = -0.000050435 Vs 10:01:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = 0.000021560 Vs 10:01:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = -0.000051644 Vs 10:01:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = 0.000022912 Vs 10:01:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = -0.000049359 Vs 10:01:42 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0050000 m VT = 0.000036056 +- 0.000000582 Vs 10:01:42 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0050000 m, Nturns = 10.0 VT = 0.000036056 +- 0.000000582 Vs BL = 0.00072112 +- 0.00001163 Tm 10:01:42 Integrated Voltage Measurement... 10:01:53 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = 0.000684902 Vs 10:02:00 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = -0.000713588 Vs 10:02:06 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = 0.000685917 Vs 10:02:13 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = -0.000714791 Vs 10:02:20 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = 0.000685927 Vs 10:02:27 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = -0.000715437 Vs 10:02:34 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = 0.000684716 Vs 10:02:41 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = -0.000718630 Vs 10:02:41 Integrated Voltage Average and RMS of Measurements X0 = 0.0050000 m, Delta X = 0.0050000 m VT = 0.000700489 +- 0.000000867 Vs 10:02:41 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0050000 m, dx = 0.0050000 m, Nturns = 10.0 VT = 0.000700489 +- 0.000000867 Vs BL = 0.01400977 +- 0.00001734 Tm 10:02:41 Integrated Voltage Measurement... 10:02:52 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = 0.001335980 Vs 10:02:59 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = -0.001373113 Vs 10:03:06 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = 0.001336074 Vs 10:03:12 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = -0.001370061 Vs 10:03:19 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = 0.001337871 Vs 10:03:26 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = -0.001372387 Vs 10:03:33 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = 0.001335532 Vs 10:03:40 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = -0.001374827 Vs 10:03:40 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0050000 m VT = 0.001354481 +- 0.000000853 Vs 10:03:40 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0050000 m, Nturns = 10.0 VT = 0.001354481 +- 0.000000853 Vs BL = 0.02708961 +- 0.00001706 Tm 10:03:45 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00071 0.00001 1 2.64326 0.00116 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- -0.0100000 -0.02569 0.00002 -0.02572 0.00003 -0.0050000 -0.01259 0.00001 -0.01251 -0.00008 0.0000000 0.00072 0.00001 0.00071 0.00001 0.0050000 0.01401 0.00002 0.01392 0.00009 0.0100000 0.02709 0.00002 0.02714 -0.00005 10:03:45 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 5 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0100 -0.02569 0.00002 -0.0050 -0.01259 0.00001 0.0000 0.00072 0.00001 0.0050 0.01401 0.00002 0.0100 0.02709 0.00002 SL = 2.6432643 +- 0.0011648 Tm^2/m^n 10:03:45 Quadrupole Strength Calculation Check Slope = 2.643264 Tm/m, Inter = 0.000708 Tm, Sig_slope = 0.004814 Tm/m, Est_sig = 0.000076 Tm GL = 2.643264 +- 0.004814 T 10:03:45 Magnet Strength Measurement Harmonic Number = 2 SL = 2.6432643 +- 0.0011648 Tm^2/m^n 10:03:46 Magnet Current, Imag = 119.9771 A Vtrans = 9.598170 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:03:48 Magnet Current, Imag = 119.9771 A Vtrans = 9.598170 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:03:49 Magnet Current, Imag = 119.9774 A Vtrans = 9.598190 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:03:50 Magnet Current, Imag = 119.9772 A Vtrans = 9.598180 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:03:50 Magnet Current Measurement: Imag = 119.9772 +- 0.0001 A 10:03:51 Magnet current ramping to 0.0000 A...