SLAC Magnetic Measurements Date: 01-06-2010 Time: 15:17:57 Project: E163 Magnet Type: quad Magnet Name: PMQ3 Serial Number: 3 Run Number: 22 Measurement Device: 1 wire Operator: sda Comment: Integrated Strength vs x at roll = +3 deg. Test Currents (A): 0.0 0.0 0.0 Integrated Field Strength vs X Distance the wire was moved = 0.000400 m Number of turns in the wire = 1 Number of measurements for averaging = 7 X0 Imag sigImag BL sigBL (m) (A) (A) (Tm) (Tm) ---------- --------+-------- -----------+----------- -0.001200 NaN 0.000 0.00925173 0.00010623 -0.000800 NaN 0.000 0.00640089 0.00009226 -0.000400 NaN 0.000 0.00349155 0.00005427 0.000000 NaN 0.000 0.00049529 0.00010830 0.000400 NaN 0.000 -0.00254571 0.00004734 0.000800 NaN 0.000 -0.00559949 0.00007520 0.001200 NaN 0.000 -0.00849078 0.00007017 -0.001200 NaN 0.000 0.00923328 0.00007639 -0.000800 NaN 0.000 0.00640099 0.00005475 -0.000400 NaN 0.000 0.00343737 0.00004991 0.000000 NaN 0.000 0.00053304 0.00007192 0.000400 NaN 0.000 -0.00259384 0.00009096 0.000800 NaN 0.000 -0.00561381 0.00006047 0.001200 NaN 0.000 -0.00853619 0.00012955 -0.001200 NaN 0.000 0.00925392 0.00006757 -0.000800 NaN 0.000 0.00637751 0.00005554 -0.000400 NaN 0.000 0.00350489 0.00005943 0.000000 NaN 0.000 0.00051555 0.00003673 0.000400 NaN 0.000 -0.00258038 0.00005358 0.000800 NaN 0.000 -0.00556190 0.00006792 0.001200 NaN 0.000 -0.00845966 0.00010121