SLAC Magnetic Measurements Date: 01-05-2010 Time: 11:49:54 Project: E163 Magnet Type: quad Magnet Name: PMQ3 Serial Number: 3 Run Number: 18 Measurement Device: 1 wire Operator: sda Comment: Integrated Strength vs x at roll = -5 deg. Test Currents (A): 0.0 0.0 0.0 Integrated Field Strength vs X Distance the wire was moved = 0.000400 m Number of turns in the wire = 1 Number of measurements for averaging = 7 X0 Imag sigImag BL sigBL (m) (A) (A) (Tm) (Tm) ---------- --------+-------- -----------+----------- -0.001200 NaN 0.000 0.00835955 0.00004004 -0.000800 NaN 0.000 0.00543148 0.00004687 -0.000400 NaN 0.000 0.00238841 0.00005395 0.000000 NaN 0.000 -0.00054886 0.00011206 0.000400 NaN 0.000 -0.00343349 0.00010023 0.000800 NaN 0.000 -0.00630974 0.00005283 0.001200 NaN 0.000 -0.00925488 0.00006105 -0.001200 NaN 0.000 0.00836901 0.00007579 -0.000800 NaN 0.000 0.00538655 0.00006611 -0.000400 NaN 0.000 0.00239975 0.00008424 0.000000 NaN 0.000 -0.00055949 0.00005445 0.000400 NaN 0.000 -0.00344975 0.00008591 0.000800 NaN 0.000 -0.00637919 0.00009887 0.001200 NaN 0.000 -0.00927690 0.00004918 -0.001200 NaN 0.000 0.00838421 0.00005258 -0.000800 NaN 0.000 0.00539781 0.00003112 -0.000400 NaN 0.000 0.00237721 0.00008539 0.000000 NaN 0.000 -0.00062437 0.00007887 0.000400 NaN 0.000 -0.00344993 0.00006405 0.000800 NaN 0.000 -0.00635319 0.00008381 0.001200 NaN 0.000 -0.00929453 0.00005624