SLAC Magnetic Measurements Date: 12-10-2009 Time: 17:46:53 Project: E163 Magnet Type: quad Magnet Name: PMQ1 Serial Number: 1 Run Number: 14 Measurement Device: 1 wire Operator: sda Comment: Integrated Strength vs x at roll = +3 deg. Test Currents (A): 0.0 0.0 0.0 0.0 17:47:23 Name = None, is zeroed 17:47:23 Integrated Voltage Measurement... 17:47:40 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000144 V 17:47:40 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001899 Vs 17:47:57 Voltage Offset Correction: v_off_ini = 0.000000000 V, v_off_fin = 0.000000289 V 17:47:57 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001887 Vs 17:48:14 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000000 V 17:48:14 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001964 Vs 17:48:31 Voltage Offset Correction: v_off_ini = -0.000000072 V, v_off_fin = 0.000000072 V 17:48:31 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001871 Vs 17:48:48 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = -0.000000072 V 17:48:48 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001948 Vs 17:49:05 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000217 V 17:49:05 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001885 Vs 17:49:22 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000000 V 17:49:22 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001944 Vs 17:49:39 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = -0.000000072 V 17:49:39 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001874 Vs 17:49:56 Voltage Offset Correction: v_off_ini = -0.000000072 V, v_off_fin = -0.000000072 V 17:49:56 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001932 Vs 17:50:13 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000289 V 17:50:13 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001942 Vs 17:50:30 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000144 V 17:50:30 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001939 Vs 17:50:47 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000217 V 17:50:47 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001910 Vs 17:51:04 Voltage Offset Correction: v_off_ini = -0.000000072 V, v_off_fin = -0.000000072 V 17:51:04 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002014 Vs 17:51:21 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000144 V 17:51:21 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001904 Vs 17:51:21 Integrated Voltage Average and RMS of Measurements X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001922 +- 0.000000019 Vs 17:51:21 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0012000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000001922 +- 0.000000019 Vs BL = 0.00480576 +- 0.00004844 Tm 17:51:21 Integrated Voltage Measurement... 17:51:38 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000144 V 17:51:38 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001297 Vs 17:51:55 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000217 V 17:51:55 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001245 Vs 17:52:12 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000289 V 17:52:12 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001283 Vs 17:52:29 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000433 V 17:52:29 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001266 Vs 17:52:46 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000144 V 17:52:46 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001319 Vs 17:53:03 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000144 V 17:53:03 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001249 Vs 17:53:20 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000000 V 17:53:20 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001346 Vs 17:53:36 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000289 V 17:53:36 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001326 Vs 17:53:53 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000000 V 17:53:53 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001313 Vs 17:54:10 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000433 V 17:54:10 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001312 Vs 17:54:27 Voltage Offset Correction: v_off_ini = -0.000000072 V, v_off_fin = 0.000000000 V 17:54:27 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001315 Vs 17:54:44 Voltage Offset Correction: v_off_ini = -0.000000072 V, v_off_fin = 0.000000144 V 17:54:44 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001288 Vs 17:55:01 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = -0.000000217 V 17:55:01 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001349 Vs 17:55:18 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000361 V 17:55:18 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001330 Vs 17:55:18 Integrated Voltage Average and RMS of Measurements X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001303 +- 0.000000026 Vs 17:55:18 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0008000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000001303 +- 0.000000026 Vs BL = 0.00325682 +- 0.00006487 Tm 17:55:18 Integrated Voltage Measurement... 17:55:35 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000000 V 17:55:35 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000701 Vs 17:55:52 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000144 V 17:55:52 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000660 Vs 17:56:09 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000144 V 17:56:09 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000651 Vs 17:56:26 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 17:56:26 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000632 Vs 17:56:43 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000289 V 17:56:43 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000666 Vs 17:57:00 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000289 V 17:57:00 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000633 Vs 17:57:17 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000144 V 17:57:17 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000701 Vs 17:57:34 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000144 V 17:57:34 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000615 Vs 17:57:51 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000000 V 17:57:51 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000700 Vs 17:58:08 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000217 V 17:58:08 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000643 Vs 17:58:25 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = -0.000000072 V 17:58:25 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000675 Vs 17:58:42 Voltage Offset Correction: v_off_ini = -0.000000072 V, v_off_fin = 0.000000072 V 17:58:42 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000636 Vs 17:58:59 Voltage Offset Correction: v_off_ini = -0.000000072 V, v_off_fin = 0.000000000 V 17:58:59 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000731 Vs 17:59:16 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000217 V 17:59:16 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000640 Vs 17:59:16 Integrated Voltage Average and RMS of Measurements X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000663 +- 0.000000015 Vs 17:59:16 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0004000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000000663 +- 0.000000015 Vs BL = 0.00165762 +- 0.00003781 Tm 17:59:16 Integrated Voltage Measurement... 17:59:33 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000000 V 17:59:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = -0.000000034 Vs 17:59:50 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000433 V 17:59:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000026 Vs 18:00:07 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000217 V 18:00:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000035 Vs 18:00:24 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 18:00:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000008 Vs 18:00:41 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000144 V 18:00:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = -0.000000008 Vs 18:00:58 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000289 V 18:00:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000003 Vs 18:01:15 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 18:01:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = -0.000000023 Vs 18:01:31 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000217 V 18:01:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000023 Vs 18:01:48 Voltage Offset Correction: v_off_ini = -0.000000072 V, v_off_fin = -0.000000000 V 18:01:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000075 Vs 18:02:05 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000000 V 18:02:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000004 Vs 18:02:22 Voltage Offset Correction: v_off_ini = -0.000000072 V, v_off_fin = 0.000000072 V 18:02:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000006 Vs 18:02:39 Voltage Offset Correction: v_off_ini = -0.000000072 V, v_off_fin = -0.000000000 V 18:02:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = 0.000000072 Vs 18:02:56 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000144 V 18:02:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = -0.000000021 Vs 18:03:13 Voltage Offset Correction: v_off_ini = 0.000000000 V, v_off_fin = 0.000000289 V 18:03:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000023 Vs 18:03:13 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000003 +- 0.000000021 Vs 18:03:13 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000000003 +- 0.000000021 Vs BL = 0.00000794 +- 0.00005251 Tm 18:03:13 Integrated Voltage Measurement... 18:03:30 Voltage Offset Correction: v_off_ini = 0.000000000 V, v_off_fin = 0.000000000 V 18:03:30 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000572 Vs 18:03:47 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000361 V 18:03:47 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000599 Vs 18:04:04 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000000 V 18:04:04 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000548 Vs 18:04:21 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000361 V 18:04:21 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000698 Vs 18:04:38 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000144 V 18:04:38 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000618 Vs 18:04:55 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000289 V 18:04:55 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000601 Vs 18:05:12 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000361 V 18:05:12 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000688 Vs 18:05:29 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000217 V 18:05:29 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000605 Vs 18:05:46 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = -0.000000072 V 18:05:46 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000631 Vs 18:06:03 Voltage Offset Correction: v_off_ini = -0.000000072 V, v_off_fin = 0.000000217 V 18:06:03 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000656 Vs 18:06:20 Voltage Offset Correction: v_off_ini = 0.000000000 V, v_off_fin = 0.000000000 V 18:06:20 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000635 Vs 18:06:37 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000217 V 18:06:37 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000578 Vs 18:06:54 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000000 V 18:06:54 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000635 Vs 18:07:11 Voltage Offset Correction: v_off_ini = 0.000000000 V, v_off_fin = 0.000000144 V 18:07:11 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000643 Vs 18:07:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000622 +- 0.000000021 Vs 18:07:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0004000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000000622 +- 0.000000021 Vs BL = -0.00155510 +- 0.00005247 Tm 18:07:11 Integrated Voltage Measurement... 18:07:28 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = -0.000000072 V 18:07:28 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001311 Vs 18:07:45 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000361 V 18:07:45 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001332 Vs 18:08:02 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000144 V 18:08:02 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001301 Vs 18:08:19 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000217 V 18:08:19 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001273 Vs 18:08:36 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000000 V 18:08:36 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001271 Vs 18:08:53 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000217 V 18:08:53 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001331 Vs 18:09:10 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000072 V 18:09:10 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001264 Vs 18:09:27 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = -0.000000072 V 18:09:27 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001336 Vs 18:09:44 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = -0.000000072 V 18:09:44 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001288 Vs 18:10:00 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000144 V 18:10:00 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001338 Vs 18:10:17 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000000 V 18:10:17 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001324 Vs 18:10:34 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000361 V 18:10:34 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001315 Vs 18:10:51 Voltage Offset Correction: v_off_ini = -0.000000217 V, v_off_fin = -0.000000289 V 18:10:51 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001257 Vs 18:11:08 Voltage Offset Correction: v_off_ini = -0.000000072 V, v_off_fin = 0.000000072 V 18:11:08 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001346 Vs 18:11:08 Integrated Voltage Average and RMS of Measurements X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001306 +- 0.000000011 Vs 18:11:08 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0008000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000001306 +- 0.000000011 Vs BL = -0.00326538 +- 0.00002849 Tm 18:11:08 Integrated Voltage Measurement... 18:11:25 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000072 V 18:11:25 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001944 Vs 18:11:42 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000144 V 18:11:42 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001859 Vs 18:11:59 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000000 V 18:11:59 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001943 Vs 18:12:16 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000072 V 18:12:16 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001972 Vs 18:12:33 Voltage Offset Correction: v_off_ini = -0.000000072 V, v_off_fin = 0.000000000 V 18:12:33 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001915 Vs 18:12:50 Voltage Offset Correction: v_off_ini = -0.000000144 V, v_off_fin = -0.000000072 V 18:12:50 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001911 Vs 18:13:07 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = -0.000000217 V 18:13:07 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001880 Vs 18:13:24 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = -0.000000072 V 18:13:24 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001997 Vs 18:13:41 Voltage Offset Correction: v_off_ini = 0.000000000 V, v_off_fin = -0.000000072 V 18:13:41 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001923 Vs 18:13:58 Voltage Offset Correction: v_off_ini = -0.000000144 V, v_off_fin = 0.000000000 V 18:13:58 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001952 Vs 18:14:15 Voltage Offset Correction: v_off_ini = -0.000000072 V, v_off_fin = -0.000000217 V 18:14:15 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001909 Vs 18:14:32 Voltage Offset Correction: v_off_ini = -0.000000072 V, v_off_fin = -0.000000072 V 18:14:32 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001963 Vs 18:14:49 Voltage Offset Correction: v_off_ini = -0.000000144 V, v_off_fin = -0.000000144 V 18:14:49 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001872 Vs 18:15:06 Voltage Offset Correction: v_off_ini = 0.000000000 V, v_off_fin = 0.000000072 V 18:15:06 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001981 Vs 18:15:06 Integrated Voltage Average and RMS of Measurements X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001930 +- 0.000000017 Vs 18:15:06 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0012000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000001930 +- 0.000000017 Vs BL = -0.00482480 +- 0.00004261 Tm 18:15:14 Integrated Voltage Measurement... 18:15:31 Voltage Offset Correction: v_off_ini = -0.000000144 V, v_off_fin = -0.000000072 V 18:15:31 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001972 Vs 18:15:48 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000000 V 18:15:48 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001885 Vs 18:16:05 Voltage Offset Correction: v_off_ini = -0.000000144 V, v_off_fin = -0.000000072 V 18:16:05 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001959 Vs 18:16:22 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000000 V 18:16:22 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001893 Vs 18:16:39 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000144 V 18:16:39 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001944 Vs 18:16:56 Voltage Offset Correction: v_off_ini = -0.000000072 V, v_off_fin = -0.000000072 V 18:16:56 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001848 Vs 18:17:13 Voltage Offset Correction: v_off_ini = -0.000000072 V, v_off_fin = 0.000000000 V 18:17:13 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001981 Vs 18:17:30 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000144 V 18:17:30 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001877 Vs 18:17:47 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000144 V 18:17:47 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001909 Vs 18:18:04 Voltage Offset Correction: v_off_ini = 0.000000000 V, v_off_fin = 0.000000000 V 18:18:04 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001803 Vs 18:18:21 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000144 V 18:18:21 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001915 Vs 18:18:38 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 18:18:38 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001856 Vs 18:18:55 Voltage Offset Correction: v_off_ini = -0.000000072 V, v_off_fin = 0.000000000 V 18:18:55 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002022 Vs 18:19:12 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000217 V 18:19:12 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001918 Vs 18:19:12 Integrated Voltage Average and RMS of Measurements X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001913 +- 0.000000034 Vs 18:19:12 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0012000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000001913 +- 0.000000034 Vs BL = 0.00478263 +- 0.00008575 Tm 18:19:12 Integrated Voltage Measurement... 18:19:29 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000217 V 18:19:29 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001266 Vs 18:19:46 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 18:19:46 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001280 Vs 18:20:03 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000072 V 18:20:03 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001311 Vs 18:20:20 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000289 V 18:20:20 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001321 Vs 18:20:37 Voltage Offset Correction: v_off_ini = -0.000000072 V, v_off_fin = -0.000000217 V 18:20:37 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001367 Vs 18:20:54 Voltage Offset Correction: v_off_ini = -0.000000072 V, v_off_fin = 0.000000144 V 18:20:54 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001241 Vs 18:21:11 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = -0.000000072 V 18:21:11 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001351 Vs 18:21:27 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = -0.000000072 V 18:21:28 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001233 Vs 18:21:44 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000000 V 18:21:44 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001270 Vs 18:22:01 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000000 V 18:22:01 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001283 Vs 18:22:18 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000217 V 18:22:18 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001319 Vs 18:22:35 Voltage Offset Correction: v_off_ini = -0.000000144 V, v_off_fin = 0.000000144 V 18:22:35 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001254 Vs 18:22:52 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000072 V 18:22:52 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001307 Vs 18:23:09 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000144 V 18:23:09 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001256 Vs 18:23:09 Integrated Voltage Average and RMS of Measurements X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001290 +- 0.000000014 Vs 18:23:09 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0008000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000001290 +- 0.000000014 Vs BL = 0.00322488 +- 0.00003565 Tm 18:23:09 Integrated Voltage Measurement... 18:23:26 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = -0.000000072 V 18:23:26 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000686 Vs 18:23:43 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000144 V 18:23:43 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000659 Vs 18:24:00 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = -0.000000217 V 18:24:00 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000720 Vs 18:24:17 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000000 V 18:24:17 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000633 Vs 18:24:34 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = -0.000000072 V 18:24:34 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000658 Vs 18:24:51 Voltage Offset Correction: v_off_ini = -0.000000072 V, v_off_fin = 0.000000144 V 18:24:51 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000617 Vs 18:25:08 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = -0.000000072 V 18:25:08 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000643 Vs 18:25:25 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000217 V 18:25:25 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000692 Vs 18:25:42 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000000 V 18:25:42 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000681 Vs 18:25:59 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = -0.000000072 V 18:25:59 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000643 Vs 18:26:16 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000144 V 18:26:16 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000652 Vs 18:26:33 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000289 V 18:26:33 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000651 Vs 18:26:50 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000361 V 18:26:50 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000616 Vs 18:27:07 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 18:27:07 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000652 Vs 18:27:07 Integrated Voltage Average and RMS of Measurements X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000657 +- 0.000000016 Vs 18:27:07 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0004000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000000657 +- 0.000000016 Vs BL = 0.00164326 +- 0.00003896 Tm 18:27:07 Integrated Voltage Measurement... 18:27:24 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000144 V 18:27:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000032 Vs 18:27:41 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000433 V 18:27:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000026 Vs 18:27:58 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000361 V 18:27:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000055 Vs 18:28:15 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000144 V 18:28:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000015 Vs 18:28:32 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 18:28:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = -0.000000005 Vs 18:28:49 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000433 V 18:28:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = 0.000000025 Vs 18:29:05 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = -0.000000072 V 18:29:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000091 Vs 18:29:22 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000505 V 18:29:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000025 Vs 18:29:39 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000144 V 18:29:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000022 Vs 18:29:56 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000433 V 18:29:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000028 Vs 18:30:13 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000217 V 18:30:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000046 Vs 18:30:30 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 18:30:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000019 Vs 18:30:47 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000289 V 18:30:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000031 Vs 18:31:04 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000361 V 18:31:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000015 Vs 18:31:04 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000027 +- 0.000000020 Vs 18:31:04 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000000027 +- 0.000000020 Vs BL = 0.00006677 +- 0.00005011 Tm 18:31:04 Integrated Voltage Measurement... 18:31:21 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000578 V 18:31:21 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000743 Vs 18:31:38 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000794 V 18:31:38 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000634 Vs 18:31:55 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 18:31:55 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000613 Vs 18:32:12 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000433 V 18:32:12 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000661 Vs 18:32:29 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000578 V 18:32:29 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000602 Vs 18:32:46 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 18:32:46 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000676 Vs 18:33:03 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 18:33:03 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000650 Vs 18:33:20 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 18:33:20 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000654 Vs 18:33:37 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000578 V 18:33:37 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000639 Vs 18:33:54 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000866 V 18:33:54 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000608 Vs 18:34:11 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000361 V 18:34:11 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000619 Vs 18:34:28 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000361 V 18:34:28 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000676 Vs 18:34:45 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000361 V 18:34:45 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000626 Vs 18:35:02 Voltage Offset Correction: v_off_ini = 0.000000794 V, v_off_fin = 0.000000578 V 18:35:02 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000602 Vs 18:35:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000643 +- 0.000000022 Vs 18:35:02 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0004000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000000643 +- 0.000000022 Vs BL = -0.00160786 +- 0.00005518 Tm 18:35:02 Integrated Voltage Measurement... 18:35:19 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000578 V 18:35:19 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001360 Vs 18:35:36 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000794 V 18:35:36 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001277 Vs 18:35:53 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000578 V 18:35:53 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001350 Vs 18:36:10 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 18:36:10 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001266 Vs 18:36:27 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000217 V 18:36:27 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001260 Vs 18:36:44 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000505 V 18:36:44 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001345 Vs 18:37:01 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000144 V 18:37:01 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001283 Vs 18:37:18 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 18:37:18 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001315 Vs 18:37:34 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000722 V 18:37:34 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001332 Vs 18:37:51 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000794 V 18:37:51 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001261 Vs 18:38:08 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000289 V 18:38:08 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001271 Vs 18:38:25 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000722 V 18:38:25 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001288 Vs 18:38:42 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 18:38:42 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001281 Vs 18:38:59 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000578 V 18:38:59 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001337 Vs 18:38:59 Integrated Voltage Average and RMS of Measurements X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001302 +- 0.000000012 Vs 18:38:59 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0008000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000001302 +- 0.000000012 Vs BL = -0.00325463 +- 0.00002877 Tm 18:38:59 Integrated Voltage Measurement... 18:39:16 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000289 V 18:39:16 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001909 Vs 18:39:33 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000578 V 18:39:33 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001911 Vs 18:39:50 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 18:39:50 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001921 Vs 18:40:07 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000722 V 18:40:07 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001908 Vs 18:40:24 Voltage Offset Correction: v_off_ini = 0.000000794 V, v_off_fin = 0.000000794 V 18:40:24 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001940 Vs 18:40:41 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000433 V 18:40:41 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001999 Vs 18:40:58 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000578 V 18:40:58 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001954 Vs 18:41:15 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000505 V 18:41:15 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001946 Vs 18:41:32 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000433 V 18:41:32 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001910 Vs 18:41:49 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000361 V 18:41:49 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001991 Vs 18:42:06 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000289 V 18:42:06 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001936 Vs 18:42:23 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000794 V 18:42:23 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001870 Vs 18:42:40 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 18:42:40 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001852 Vs 18:42:57 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000433 V 18:42:57 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001922 Vs 18:42:57 Integrated Voltage Average and RMS of Measurements X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001926 +- 0.000000028 Vs 18:42:57 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0012000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000001926 +- 0.000000028 Vs BL = -0.00481598 +- 0.00007021 Tm 18:43:05 Integrated Voltage Measurement... 18:43:23 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000578 V 18:43:23 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001886 Vs 18:43:40 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000433 V 18:43:40 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001913 Vs 18:43:57 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000433 V 18:43:57 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001973 Vs 18:44:13 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000578 V 18:44:14 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001923 Vs 18:44:30 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000144 V 18:44:30 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001906 Vs 18:44:47 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000433 V 18:44:47 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001863 Vs 18:45:04 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000361 V 18:45:04 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001879 Vs 18:45:21 Voltage Offset Correction: v_off_ini = 0.000000794 V, v_off_fin = 0.000000650 V 18:45:21 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001967 Vs 18:45:38 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000650 V 18:45:38 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001871 Vs 18:45:55 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000505 V 18:45:55 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001859 Vs 18:46:12 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 18:46:12 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001905 Vs 18:46:29 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000505 V 18:46:29 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001875 Vs 18:46:46 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000361 V 18:46:46 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001921 Vs 18:47:03 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000650 V 18:47:03 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001906 Vs 18:47:03 Integrated Voltage Average and RMS of Measurements X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001903 +- 0.000000025 Vs 18:47:03 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0012000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000001903 +- 0.000000025 Vs BL = 0.00475867 +- 0.00006308 Tm 18:47:03 Integrated Voltage Measurement... 18:47:20 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000505 V 18:47:20 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001226 Vs 18:47:37 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 18:47:37 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001305 Vs 18:47:54 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000650 V 18:47:54 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001287 Vs 18:48:11 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000361 V 18:48:11 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001272 Vs 18:48:28 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 18:48:28 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001281 Vs 18:48:45 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000433 V 18:48:45 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001251 Vs 18:49:02 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000433 V 18:49:02 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001279 Vs 18:49:19 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000578 V 18:49:19 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001326 Vs 18:49:36 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 18:49:36 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001226 Vs 18:49:53 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000505 V 18:49:53 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001269 Vs 18:50:09 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000433 V 18:50:09 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001219 Vs 18:50:26 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000433 V 18:50:26 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001270 Vs 18:50:43 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000217 V 18:50:43 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001345 Vs 18:51:00 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 18:51:00 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001320 Vs 18:51:00 Integrated Voltage Average and RMS of Measurements X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001277 +- 0.000000029 Vs 18:51:00 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0008000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000001277 +- 0.000000029 Vs BL = 0.00319201 +- 0.00007295 Tm 18:51:00 Integrated Voltage Measurement... 18:51:18 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000000 V 18:51:18 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000686 Vs 18:51:35 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000433 V 18:51:35 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000692 Vs 18:51:51 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000289 V 18:51:51 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000655 Vs 18:52:08 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000217 V 18:52:08 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000648 Vs 18:52:25 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000289 V 18:52:25 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000668 Vs 18:52:42 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000578 V 18:52:42 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000622 Vs 18:52:59 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 18:52:59 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000741 Vs 18:53:16 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000505 V 18:53:16 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000616 Vs 18:53:33 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000289 V 18:53:33 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000704 Vs 18:53:50 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 18:53:50 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000682 Vs 18:54:07 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000433 V 18:54:07 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000605 Vs 18:54:24 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000578 V 18:54:24 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000683 Vs 18:54:41 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000433 V 18:54:41 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000594 Vs 18:54:58 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000794 V 18:54:58 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000692 Vs 18:54:58 Integrated Voltage Average and RMS of Measurements X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000664 +- 0.000000021 Vs 18:54:58 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0004000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000000664 +- 0.000000021 Vs BL = 0.00165882 +- 0.00005174 Tm 18:54:58 Integrated Voltage Measurement... 18:55:15 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000505 V 18:55:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = -0.000000025 Vs 18:55:32 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 18:55:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = 0.000000048 Vs 18:55:49 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000433 V 18:55:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000036 Vs 18:56:06 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 18:56:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000052 Vs 18:56:23 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000578 V 18:56:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = -0.000000049 Vs 18:56:40 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000433 V 18:56:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = 0.000000013 Vs 18:56:57 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000433 V 18:56:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000025 Vs 18:57:14 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000578 V 18:57:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000030 Vs 18:57:31 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 18:57:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000049 Vs 18:57:48 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000289 V 18:57:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000004 Vs 18:58:05 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 18:58:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = -0.000000065 Vs 18:58:22 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000578 V 18:58:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000026 Vs 18:58:39 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 18:58:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000000 Vs 18:58:56 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 18:58:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000006 Vs 18:58:56 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000002 +- 0.000000029 Vs 18:58:56 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000000002 +- 0.000000029 Vs BL = 0.00000467 +- 0.00007347 Tm 18:58:56 Integrated Voltage Measurement... 18:59:13 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000289 V 18:59:13 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000617 Vs 18:59:30 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000505 V 18:59:30 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000668 Vs 18:59:47 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000361 V 18:59:47 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000604 Vs 19:00:04 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000722 V 19:00:04 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000629 Vs 19:00:21 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000361 V 19:00:21 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000619 Vs 19:00:38 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000289 V 19:00:38 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000647 Vs 19:00:55 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000361 V 19:00:55 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000601 Vs 19:01:12 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000578 V 19:01:12 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000613 Vs 19:01:28 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000433 V 19:01:29 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000572 Vs 19:01:45 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000217 V 19:01:45 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000714 Vs 19:02:02 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000361 V 19:02:02 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000600 Vs 19:02:19 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000505 V 19:02:19 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000675 Vs 19:02:36 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000433 V 19:02:36 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000623 Vs 19:02:53 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000578 V 19:02:53 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000618 Vs 19:02:53 Integrated Voltage Average and RMS of Measurements X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000628 +- 0.000000013 Vs 19:02:53 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0004000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000000628 +- 0.000000013 Vs BL = -0.00157111 +- 0.00003279 Tm 19:02:53 Integrated Voltage Measurement... 19:03:11 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000072 V 19:03:11 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001252 Vs 19:03:27 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000433 V 19:03:27 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001350 Vs 19:03:44 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000650 V 19:03:44 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001331 Vs 19:04:01 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000505 V 19:04:01 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001305 Vs 19:04:18 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000578 V 19:04:18 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001293 Vs 19:04:35 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000722 V 19:04:35 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001239 Vs 19:04:52 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 19:04:52 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001331 Vs 19:05:09 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 19:05:09 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001301 Vs 19:05:26 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 19:05:26 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001329 Vs 19:05:43 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000578 V 19:05:43 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001281 Vs 19:06:00 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000650 V 19:06:00 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001378 Vs 19:06:17 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000578 V 19:06:17 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001255 Vs 19:06:34 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000722 V 19:06:34 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001343 Vs 19:06:51 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000722 V 19:06:51 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001239 Vs 19:06:51 Integrated Voltage Average and RMS of Measurements X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001302 +- 0.000000017 Vs 19:06:51 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0008000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000001302 +- 0.000000017 Vs BL = -0.00325483 +- 0.00004312 Tm 19:06:51 Integrated Voltage Measurement... 19:07:08 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000578 V 19:07:08 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001991 Vs 19:07:25 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000505 V 19:07:25 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001904 Vs 19:07:42 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000433 V 19:07:42 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001898 Vs 19:07:59 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000505 V 19:07:59 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001959 Vs 19:08:16 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000433 V 19:08:16 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001961 Vs 19:08:33 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000505 V 19:08:33 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001906 Vs 19:08:50 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000361 V 19:08:50 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001927 Vs 19:09:07 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000433 V 19:09:07 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001982 Vs 19:09:23 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000361 V 19:09:23 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001857 Vs 19:09:40 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000578 V 19:09:40 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001960 Vs 19:09:57 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000578 V 19:09:57 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001931 Vs 19:10:14 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000578 V 19:10:14 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001913 Vs 19:10:31 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000433 V 19:10:31 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001878 Vs 19:10:48 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000578 V 19:10:48 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001963 Vs 19:10:48 Integrated Voltage Average and RMS of Measurements X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001931 +- 0.000000015 Vs 19:10:48 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0012000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000001931 +- 0.000000015 Vs BL = -0.00482653 +- 0.00003720 Tm 19:10:57 Integrated Voltage Measurement... 19:11:14 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000578 V 19:11:14 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001920 Vs 19:11:31 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000433 V 19:11:31 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001896 Vs 19:11:48 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000505 V 19:11:48 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001885 Vs 19:12:05 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000361 V 19:12:05 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001893 Vs 19:12:22 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000433 V 19:12:22 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001922 Vs 19:12:38 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000361 V 19:12:39 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001943 Vs 19:12:55 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000578 V 19:12:55 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001911 Vs 19:13:12 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 19:13:12 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001882 Vs 19:13:29 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000433 V 19:13:29 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001883 Vs 19:13:46 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 19:13:46 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001872 Vs 19:14:03 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 19:14:03 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001906 Vs 19:14:20 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000505 V 19:14:20 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001854 Vs 19:14:37 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000433 V 19:14:37 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001886 Vs 19:14:54 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000361 V 19:14:54 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001864 Vs 19:14:54 Integrated Voltage Average and RMS of Measurements X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001894 +- 0.000000019 Vs 19:14:54 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0012000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000001894 +- 0.000000019 Vs BL = 0.00473482 +- 0.00004766 Tm 19:14:54 Integrated Voltage Measurement... 19:15:11 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000361 V 19:15:11 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001312 Vs 19:15:28 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000144 V 19:15:28 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001205 Vs 19:15:45 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000433 V 19:15:45 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001299 Vs 19:16:02 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000361 V 19:16:02 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001302 Vs 19:16:19 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000433 V 19:16:19 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001311 Vs 19:16:36 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 19:16:36 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001314 Vs 19:16:53 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000217 V 19:16:53 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001321 Vs 19:17:10 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000433 V 19:17:10 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001241 Vs 19:17:27 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000361 V 19:17:27 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001272 Vs 19:17:44 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 19:17:44 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001284 Vs 19:18:01 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000217 V 19:18:01 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001364 Vs 19:18:17 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000578 V 19:18:18 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001355 Vs 19:18:34 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000433 V 19:18:34 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001339 Vs 19:18:51 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000578 V 19:18:51 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001326 Vs 19:18:51 Integrated Voltage Average and RMS of Measurements X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001303 +- 0.000000032 Vs 19:18:51 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0008000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000001303 +- 0.000000032 Vs BL = 0.00325813 +- 0.00008031 Tm 19:18:52 Integrated Voltage Measurement... 19:19:09 Voltage Offset Correction: v_off_ini = 0.000000794 V, v_off_fin = 0.000000578 V 19:19:09 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000567 Vs 19:19:26 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000578 V 19:19:26 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000640 Vs 19:19:42 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000361 V 19:19:43 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000710 Vs 19:19:59 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000505 V 19:19:59 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000629 Vs 19:20:16 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000433 V 19:20:16 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000608 Vs 19:20:33 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000650 V 19:20:33 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000677 Vs 19:20:50 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000361 V 19:20:50 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000688 Vs 19:21:07 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000505 V 19:21:07 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000626 Vs 19:21:24 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 19:21:24 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000618 Vs 19:21:41 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000794 V 19:21:41 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000643 Vs 19:21:58 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000361 V 19:21:58 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000706 Vs 19:22:15 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 19:22:15 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000662 Vs 19:22:32 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000505 V 19:22:32 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000668 Vs 19:22:49 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000361 V 19:22:49 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000624 Vs 19:22:49 Integrated Voltage Average and RMS of Measurements X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000648 +- 0.000000024 Vs 19:22:49 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0004000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000000648 +- 0.000000024 Vs BL = 0.00161907 +- 0.00006089 Tm 19:22:49 Integrated Voltage Measurement... 19:23:06 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 19:23:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000004 Vs 19:23:23 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000505 V 19:23:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = 0.000000013 Vs 19:23:40 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000722 V 19:23:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000002 Vs 19:23:57 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 19:23:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = 0.000000013 Vs 19:24:14 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000650 V 19:24:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = -0.000000004 Vs 19:24:31 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000433 V 19:24:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000048 Vs 19:24:48 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000578 V 19:24:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000002 Vs 19:25:05 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000361 V 19:25:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = 0.000000001 Vs 19:25:21 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000578 V 19:25:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = -0.000000013 Vs 19:25:38 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 19:25:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000014 Vs 19:25:55 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000650 V 19:25:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = -0.000000007 Vs 19:26:12 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000794 V 19:26:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000060 Vs 19:26:29 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000578 V 19:26:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000003 Vs 19:26:46 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 19:26:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000033 Vs 19:26:46 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000008 +- 0.000000012 Vs 19:26:46 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000000008 +- 0.000000012 Vs BL = 0.00002044 +- 0.00003106 Tm 19:26:46 Integrated Voltage Measurement... 19:27:03 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000433 V 19:27:03 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000661 Vs 19:27:20 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000505 V 19:27:20 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000691 Vs 19:27:37 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000361 V 19:27:37 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000640 Vs 19:27:54 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000722 V 19:27:54 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000659 Vs 19:28:11 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000505 V 19:28:11 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000683 Vs 19:28:28 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000433 V 19:28:28 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000639 Vs 19:28:45 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000289 V 19:28:45 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000640 Vs 19:29:02 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000650 V 19:29:02 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000590 Vs 19:29:19 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000361 V 19:29:19 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000643 Vs 19:29:36 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000505 V 19:29:36 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000669 Vs 19:29:53 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000650 V 19:29:53 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000661 Vs 19:30:10 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000722 V 19:30:10 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000602 Vs 19:30:27 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000361 V 19:30:27 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000598 Vs 19:30:44 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000650 V 19:30:44 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000634 Vs 19:30:44 Integrated Voltage Average and RMS of Measurements X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000644 +- 0.000000022 Vs 19:30:44 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0004000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000000644 +- 0.000000022 Vs BL = -0.00160922 +- 0.00005379 Tm 19:30:44 Integrated Voltage Measurement... 19:31:01 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 19:31:01 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001327 Vs 19:31:18 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000650 V 19:31:18 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001354 Vs 19:31:35 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000722 V 19:31:35 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001372 Vs 19:31:52 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000722 V 19:31:52 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001260 Vs 19:32:09 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000578 V 19:32:09 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001343 Vs 19:32:26 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000794 V 19:32:26 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001299 Vs 19:32:43 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000505 V 19:32:43 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001229 Vs 19:33:00 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000578 V 19:33:00 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001259 Vs 19:33:16 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000289 V 19:33:17 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001321 Vs 19:33:33 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000722 V 19:33:33 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001222 Vs 19:33:50 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000361 V 19:33:50 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001303 Vs 19:34:07 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000578 V 19:34:07 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001210 Vs 19:34:24 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000433 V 19:34:24 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001348 Vs 19:34:41 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000722 V 19:34:41 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001297 Vs 19:34:41 Integrated Voltage Average and RMS of Measurements X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001296 +- 0.000000035 Vs 19:34:41 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0008000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000001296 +- 0.000000035 Vs BL = -0.00324003 +- 0.00008759 Tm 19:34:42 Integrated Voltage Measurement... 19:34:59 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000361 V 19:34:59 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001927 Vs 19:35:16 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000433 V 19:35:16 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001915 Vs 19:35:33 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000144 V 19:35:33 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001886 Vs 19:35:50 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000361 V 19:35:50 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001910 Vs 19:36:07 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000144 V 19:36:07 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001894 Vs 19:36:24 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000289 V 19:36:24 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001942 Vs 19:36:40 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000433 V 19:36:41 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001869 Vs 19:36:57 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 19:36:57 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001927 Vs 19:37:14 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000505 V 19:37:14 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001920 Vs 19:37:31 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000217 V 19:37:31 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001944 Vs 19:37:48 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000578 V 19:37:48 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001978 Vs 19:38:05 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 19:38:05 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001861 Vs 19:38:22 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000505 V 19:38:22 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001946 Vs 19:38:39 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000433 V 19:38:39 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001924 Vs 19:38:39 Integrated Voltage Average and RMS of Measurements X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001917 +- 0.000000014 Vs 19:38:39 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0012000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000001917 +- 0.000000014 Vs BL = -0.00479350 +- 0.00003421 Tm 19:39:00 Name = None, is zeroed