SLAC Magnetic Measurements Date: 12-10-2009 Time: 14:38:53 Project: E163 Magnet Type: quad Magnet Name: PMQ1 Serial Number: 1 Run Number: 13 Measurement Device: 1 wire Operator: sda Comment: Integrated Strength vs x at roll = +5 deg. Test Currents (A): 0.0 0.0 0.0 0.0 14:39:23 Name = None, is zeroed 14:39:23 Integrated Voltage Measurement... 14:39:40 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 14:39:40 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002070 Vs 14:39:57 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000217 V 14:39:57 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002017 Vs 14:40:14 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000289 V 14:40:14 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002091 Vs 14:40:31 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000289 V 14:40:31 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002037 Vs 14:40:48 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000361 V 14:40:48 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002066 Vs 14:41:05 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000289 V 14:41:05 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002046 Vs 14:41:22 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 14:41:22 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002047 Vs 14:41:39 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000505 V 14:41:39 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002144 Vs 14:41:56 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000144 V 14:41:56 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002080 Vs 14:42:13 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000361 V 14:42:13 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002073 Vs 14:42:30 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000144 V 14:42:30 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002113 Vs 14:42:47 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000289 V 14:42:47 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002061 Vs 14:43:04 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 14:43:04 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002069 Vs 14:43:21 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000361 V 14:43:21 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002063 Vs 14:43:21 Integrated Voltage Average and RMS of Measurements X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002070 +- 0.000000017 Vs 14:43:21 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0012000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000002070 +- 0.000000017 Vs BL = 0.00517470 +- 0.00004137 Tm 14:43:21 Integrated Voltage Measurement... 14:43:38 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000578 V 14:43:38 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001371 Vs 14:43:55 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000361 V 14:43:55 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001426 Vs 14:44:12 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000578 V 14:44:12 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001467 Vs 14:44:29 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000578 V 14:44:29 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001511 Vs 14:44:46 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 14:44:46 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001500 Vs 14:45:03 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000433 V 14:45:03 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001440 Vs 14:45:20 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000361 V 14:45:20 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001446 Vs 14:45:36 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000433 V 14:45:36 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001486 Vs 14:45:53 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000217 V 14:45:53 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001478 Vs 14:46:10 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000650 V 14:46:10 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001476 Vs 14:46:27 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000578 V 14:46:27 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001383 Vs 14:46:44 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000794 V 14:46:44 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001509 Vs 14:47:01 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 14:47:01 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001481 Vs 14:47:18 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000433 V 14:47:18 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001460 Vs 14:47:18 Integrated Voltage Average and RMS of Measurements X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001460 +- 0.000000028 Vs 14:47:18 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0008000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000001460 +- 0.000000028 Vs BL = 0.00364886 +- 0.00006910 Tm 14:47:18 Integrated Voltage Measurement... 14:47:35 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000289 V 14:47:35 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000853 Vs 14:47:52 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000433 V 14:47:52 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000828 Vs 14:48:09 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 14:48:09 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000832 Vs 14:48:26 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000505 V 14:48:26 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000876 Vs 14:48:43 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000144 V 14:48:43 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000903 Vs 14:49:00 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 14:49:00 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000847 Vs 14:49:17 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000072 V 14:49:17 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000871 Vs 14:49:34 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000217 V 14:49:34 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000790 Vs 14:49:51 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000072 V 14:49:51 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000840 Vs 14:50:08 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000289 V 14:50:08 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000832 Vs 14:50:25 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000217 V 14:50:25 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000893 Vs 14:50:42 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 14:50:42 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000789 Vs 14:50:59 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 14:50:59 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000820 Vs 14:51:15 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000289 V 14:51:15 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000831 Vs 14:51:16 Integrated Voltage Average and RMS of Measurements X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000843 +- 0.000000015 Vs 14:51:16 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0004000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000000843 +- 0.000000015 Vs BL = 0.00210785 +- 0.00003869 Tm 14:51:16 Integrated Voltage Measurement... 14:51:33 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000072 V 14:51:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000252 Vs 14:51:50 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000433 V 14:51:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000197 Vs 14:52:07 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000144 V 14:52:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000175 Vs 14:52:24 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000289 V 14:52:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000173 Vs 14:52:40 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000144 V 14:52:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000188 Vs 14:52:57 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000217 V 14:52:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000174 Vs 14:53:14 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000578 V 14:53:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000140 Vs 14:53:31 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000505 V 14:53:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000219 Vs 14:53:48 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000217 V 14:53:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000208 Vs 14:54:05 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000361 V 14:54:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000177 Vs 14:54:22 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = -0.000000072 V 14:54:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000246 Vs 14:54:39 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000217 V 14:54:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000163 Vs 14:54:56 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000289 V 14:54:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000136 Vs 14:55:13 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000361 V 14:55:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000159 Vs 14:55:13 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000186 +- 0.000000023 Vs 14:55:13 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000000186 +- 0.000000023 Vs BL = 0.00046540 +- 0.00005635 Tm 14:55:13 Integrated Voltage Measurement... 14:55:30 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000144 V 14:55:30 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000443 Vs 14:55:47 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000144 V 14:55:47 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000492 Vs 14:56:04 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000217 V 14:56:04 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000474 Vs 14:56:21 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000289 V 14:56:21 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000464 Vs 14:56:38 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000144 V 14:56:38 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000411 Vs 14:56:55 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000217 V 14:56:55 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000486 Vs 14:57:12 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000144 V 14:57:12 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000462 Vs 14:57:29 Voltage Offset Correction: v_off_ini = -0.000000072 V, v_off_fin = 0.000000289 V 14:57:29 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000509 Vs 14:57:46 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000144 V 14:57:46 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000452 Vs 14:58:03 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000144 V 14:58:03 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000542 Vs 14:58:20 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000217 V 14:58:20 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000433 Vs 14:58:37 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000144 V 14:58:37 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000506 Vs 14:58:54 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000000 V 14:58:54 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000430 Vs 14:59:11 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000289 V 14:59:11 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000440 Vs 14:59:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000467 +- 0.000000019 Vs 14:59:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0004000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000000467 +- 0.000000019 Vs BL = -0.00116853 +- 0.00004800 Tm 14:59:11 Integrated Voltage Measurement... 14:59:28 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000217 V 14:59:28 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001159 Vs 14:59:45 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000361 V 14:59:45 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001162 Vs 15:00:02 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000578 V 15:00:02 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001118 Vs 15:00:19 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000650 V 15:00:19 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001161 Vs 15:00:36 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000289 V 15:00:36 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001109 Vs 15:00:53 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000433 V 15:00:53 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001108 Vs 15:01:10 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000217 V 15:01:10 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001072 Vs 15:01:27 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000433 V 15:01:27 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001136 Vs 15:01:44 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000217 V 15:01:44 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001086 Vs 15:02:00 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 15:02:00 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001128 Vs 15:02:17 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000361 V 15:02:17 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001074 Vs 15:02:34 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000505 V 15:02:34 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001102 Vs 15:02:51 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 15:02:51 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001146 Vs 15:03:08 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000361 V 15:03:08 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001107 Vs 15:03:08 Integrated Voltage Average and RMS of Measurements X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001119 +- 0.000000023 Vs 15:03:08 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0008000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000001119 +- 0.000000023 Vs BL = -0.00279817 +- 0.00005712 Tm 15:03:08 Integrated Voltage Measurement... 15:03:26 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000072 V 15:03:26 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001698 Vs 15:03:42 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000289 V 15:03:42 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001714 Vs 15:03:59 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000433 V 15:03:59 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001740 Vs 15:04:16 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 15:04:16 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001740 Vs 15:04:33 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000433 V 15:04:33 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001737 Vs 15:04:50 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000289 V 15:04:50 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001704 Vs 15:05:07 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000361 V 15:05:07 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001778 Vs 15:05:24 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 15:05:24 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001671 Vs 15:05:41 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000289 V 15:05:41 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001661 Vs 15:05:58 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000217 V 15:05:58 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001755 Vs 15:06:15 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000072 V 15:06:15 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001694 Vs 15:06:32 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000289 V 15:06:32 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001711 Vs 15:06:49 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000000 V 15:06:49 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001667 Vs 15:07:06 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000217 V 15:07:06 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001753 Vs 15:07:06 Integrated Voltage Average and RMS of Measurements X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001716 +- 0.000000012 Vs 15:07:06 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0012000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000001716 +- 0.000000012 Vs BL = -0.00428939 +- 0.00003059 Tm 15:07:14 Integrated Voltage Measurement... 15:07:32 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000289 V 15:07:32 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002052 Vs 15:07:49 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000433 V 15:07:49 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002086 Vs 15:08:05 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000433 V 15:08:05 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002035 Vs 15:08:22 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000361 V 15:08:22 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002127 Vs 15:08:39 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000072 V 15:08:39 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002112 Vs 15:08:56 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000217 V 15:08:56 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002105 Vs 15:09:13 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 15:09:14 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002069 Vs 15:09:31 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000217 V 15:09:31 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002026 Vs 15:09:48 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000289 V 15:09:48 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002099 Vs 15:10:05 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000144 V 15:10:05 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002044 Vs 15:10:22 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000361 V 15:10:22 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002108 Vs 15:10:39 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000217 V 15:10:39 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002036 Vs 15:10:56 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = -0.000000072 V 15:10:56 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002136 Vs 15:11:13 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000433 V 15:11:13 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002066 Vs 15:11:13 Integrated Voltage Average and RMS of Measurements X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002079 +- 0.000000019 Vs 15:11:13 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0012000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000002079 +- 0.000000019 Vs BL = 0.00519681 +- 0.00004779 Tm 15:11:13 Integrated Voltage Measurement... 15:11:30 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000217 V 15:11:30 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001384 Vs 15:11:47 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000289 V 15:11:47 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001430 Vs 15:12:04 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000000 V 15:12:04 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001490 Vs 15:12:21 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 15:12:21 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001476 Vs 15:12:38 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 15:12:38 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001469 Vs 15:12:54 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000361 V 15:12:55 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001511 Vs 15:13:11 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000217 V 15:13:11 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001406 Vs 15:13:28 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000289 V 15:13:28 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001511 Vs 15:13:45 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000217 V 15:13:45 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001457 Vs 15:14:02 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000650 V 15:14:02 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001473 Vs 15:14:19 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000289 V 15:14:19 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001459 Vs 15:14:36 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000289 V 15:14:36 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001393 Vs 15:14:53 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000361 V 15:14:53 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001489 Vs 15:15:10 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000505 V 15:15:10 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001488 Vs 15:15:10 Integrated Voltage Average and RMS of Measurements X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001460 +- 0.000000030 Vs 15:15:10 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0008000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000001460 +- 0.000000030 Vs BL = 0.00364922 +- 0.00007431 Tm 15:15:10 Integrated Voltage Measurement... 15:15:27 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = -0.000000144 V 15:15:27 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000858 Vs 15:15:44 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000144 V 15:15:44 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000776 Vs 15:16:01 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000000 V 15:16:01 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000874 Vs 15:16:18 Voltage Offset Correction: v_off_ini = -0.000000072 V, v_off_fin = 0.000000144 V 15:16:18 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000784 Vs 15:16:35 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 15:16:35 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000868 Vs 15:16:52 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000217 V 15:16:52 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000832 Vs 15:17:09 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000289 V 15:17:09 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000884 Vs 15:17:26 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000217 V 15:17:26 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000773 Vs 15:17:43 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000217 V 15:17:43 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000800 Vs 15:18:00 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000144 V 15:18:00 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000781 Vs 15:18:17 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000072 V 15:18:17 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000877 Vs 15:18:34 Voltage Offset Correction: v_off_ini = 0.000000000 V, v_off_fin = 0.000000361 V 15:18:34 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000797 Vs 15:18:51 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000144 V 15:18:51 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000781 Vs 15:19:08 Voltage Offset Correction: v_off_ini = 0.000000000 V, v_off_fin = 0.000000072 V 15:19:08 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000777 Vs 15:19:08 Integrated Voltage Average and RMS of Measurements X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000819 +- 0.000000023 Vs 15:19:08 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0004000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000000819 +- 0.000000023 Vs BL = 0.00204668 +- 0.00005868 Tm 15:19:08 Integrated Voltage Measurement... 15:19:25 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000144 V 15:19:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000183 Vs 15:19:42 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000144 V 15:19:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000138 Vs 15:19:59 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000217 V 15:19:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000200 Vs 15:20:16 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000217 V 15:20:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000165 Vs 15:20:33 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000217 V 15:20:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000147 Vs 15:20:50 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000217 V 15:20:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000143 Vs 15:21:07 Voltage Offset Correction: v_off_ini = 0.000000000 V, v_off_fin = -0.000000217 V 15:21:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000240 Vs 15:21:24 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000217 V 15:21:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000170 Vs 15:21:41 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 15:21:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000151 Vs 15:21:58 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000361 V 15:21:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000234 Vs 15:22:14 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000217 V 15:22:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000224 Vs 15:22:31 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000289 V 15:22:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000188 Vs 15:22:48 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000217 V 15:22:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000209 Vs 15:23:05 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000361 V 15:23:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000147 Vs 15:23:05 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000181 +- 0.000000021 Vs 15:23:05 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000000181 +- 0.000000021 Vs BL = 0.00045337 +- 0.00005225 Tm 15:23:05 Integrated Voltage Measurement... 15:23:22 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000144 V 15:23:23 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000467 Vs 15:23:39 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000217 V 15:23:39 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000436 Vs 15:23:56 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000289 V 15:23:56 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000446 Vs 15:24:13 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 15:24:13 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000441 Vs 15:24:30 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000361 V 15:24:30 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000442 Vs 15:24:47 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 15:24:47 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000488 Vs 15:25:04 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = -0.000000072 V 15:25:04 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000449 Vs 15:25:21 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000433 V 15:25:21 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000479 Vs 15:25:38 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000217 V 15:25:38 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000423 Vs 15:25:55 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000144 V 15:25:55 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000511 Vs 15:26:12 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000144 V 15:26:12 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000450 Vs 15:26:29 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000144 V 15:26:29 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000446 Vs 15:26:46 Voltage Offset Correction: v_off_ini = 0.000000000 V, v_off_fin = 0.000000144 V 15:26:46 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000405 Vs 15:27:03 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000000 V 15:27:03 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000534 Vs 15:27:03 Integrated Voltage Average and RMS of Measurements X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000458 +- 0.000000010 Vs 15:27:03 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0004000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000000458 +- 0.000000010 Vs BL = -0.00114579 +- 0.00002380 Tm 15:27:03 Integrated Voltage Measurement... 15:27:20 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = -0.000000072 V 15:27:20 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001105 Vs 15:27:37 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000217 V 15:27:37 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001103 Vs 15:27:54 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000072 V 15:27:54 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001081 Vs 15:28:11 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000361 V 15:28:11 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001090 Vs 15:28:28 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000217 V 15:28:28 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001058 Vs 15:28:45 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000433 V 15:28:45 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001105 Vs 15:29:01 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000217 V 15:29:02 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001115 Vs 15:29:18 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000289 V 15:29:18 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001124 Vs 15:29:35 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000144 V 15:29:35 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001108 Vs 15:29:52 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000289 V 15:29:52 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001111 Vs 15:30:09 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000289 V 15:30:09 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001085 Vs 15:30:26 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000505 V 15:30:26 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001133 Vs 15:30:43 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000361 V 15:30:43 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001107 Vs 15:31:00 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000217 V 15:31:00 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001150 Vs 15:31:00 Integrated Voltage Average and RMS of Measurements X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001106 +- 0.000000016 Vs 15:31:00 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0008000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000001106 +- 0.000000016 Vs BL = -0.00276381 +- 0.00003932 Tm 15:31:00 Integrated Voltage Measurement... 15:31:17 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000578 V 15:31:17 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001775 Vs 15:31:34 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000361 V 15:31:34 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001728 Vs 15:31:51 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000072 V 15:31:51 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001734 Vs 15:32:08 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000217 V 15:32:08 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001789 Vs 15:32:25 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000144 V 15:32:25 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001736 Vs 15:32:42 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 15:32:42 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001760 Vs 15:32:59 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000433 V 15:32:59 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001746 Vs 15:33:16 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000361 V 15:33:16 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001718 Vs 15:33:33 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000000 V 15:33:33 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001669 Vs 15:33:50 Voltage Offset Correction: v_off_ini = 0.000000000 V, v_off_fin = 0.000000578 V 15:33:50 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001737 Vs 15:34:07 Voltage Offset Correction: v_off_ini = 0.000000000 V, v_off_fin = 0.000000000 V 15:34:07 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001675 Vs 15:34:24 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000144 V 15:34:24 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001741 Vs 15:34:41 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000217 V 15:34:41 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001726 Vs 15:34:58 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000217 V 15:34:58 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001745 Vs 15:34:58 Integrated Voltage Average and RMS of Measurements X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001734 +- 0.000000020 Vs 15:34:58 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0012000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000001734 +- 0.000000020 Vs BL = -0.00433579 +- 0.00005111 Tm 15:35:06 Integrated Voltage Measurement... 15:35:23 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000289 V 15:35:23 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002105 Vs 15:35:40 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000217 V 15:35:40 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002123 Vs 15:35:57 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000217 V 15:35:57 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002139 Vs 15:36:14 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 15:36:14 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002100 Vs 15:36:31 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000289 V 15:36:31 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002074 Vs 15:36:48 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000217 V 15:36:48 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002040 Vs 15:37:05 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000289 V 15:37:05 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002068 Vs 15:37:22 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 15:37:22 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002090 Vs 15:37:39 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000578 V 15:37:39 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001994 Vs 15:37:56 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000072 V 15:37:56 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002084 Vs 15:38:13 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000000 V 15:38:13 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002058 Vs 15:38:30 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000000 V 15:38:30 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002052 Vs 15:38:46 Voltage Offset Correction: v_off_ini = 0.000000000 V, v_off_fin = 0.000000000 V 15:38:47 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002085 Vs 15:39:04 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000144 V 15:39:04 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002083 Vs 15:39:04 Integrated Voltage Average and RMS of Measurements X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002078 +- 0.000000028 Vs 15:39:04 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0012000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000002078 +- 0.000000028 Vs BL = 0.00519562 +- 0.00007030 Tm 15:39:04 Integrated Voltage Measurement... 15:39:21 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = -0.000000072 V 15:39:21 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001416 Vs 15:39:38 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000072 V 15:39:38 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001435 Vs 15:39:55 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = -0.000000072 V 15:39:55 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001465 Vs 15:40:12 Voltage Offset Correction: v_off_ini = -0.000000072 V, v_off_fin = -0.000000144 V 15:40:12 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001460 Vs 15:40:29 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = -0.000000072 V 15:40:29 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001444 Vs 15:40:46 Voltage Offset Correction: v_off_ini = 0.000000000 V, v_off_fin = -0.000000072 V 15:40:46 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001457 Vs 15:41:02 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = -0.000000072 V 15:41:02 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001445 Vs 15:41:19 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000072 V 15:41:19 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001464 Vs 15:41:36 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000072 V 15:41:36 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001464 Vs 15:41:53 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000144 V 15:41:53 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001474 Vs 15:42:10 Voltage Offset Correction: v_off_ini = -0.000000072 V, v_off_fin = 0.000000000 V 15:42:10 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001522 Vs 15:42:27 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000217 V 15:42:27 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001482 Vs 15:42:44 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000433 V 15:42:44 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001433 Vs 15:43:01 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000578 V 15:43:01 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001440 Vs 15:43:01 Integrated Voltage Average and RMS of Measurements X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001457 +- 0.000000023 Vs 15:43:01 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0008000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000001457 +- 0.000000023 Vs BL = 0.00364305 +- 0.00005727 Tm 15:43:01 Integrated Voltage Measurement... 15:43:18 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000072 V 15:43:18 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000816 Vs 15:43:35 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000433 V 15:43:35 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000845 Vs 15:43:52 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000361 V 15:43:52 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000823 Vs 15:44:09 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000289 V 15:44:09 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000834 Vs 15:44:26 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000144 V 15:44:26 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000806 Vs 15:44:43 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000072 V 15:44:43 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000831 Vs 15:45:00 Voltage Offset Correction: v_off_ini = -0.000000072 V, v_off_fin = 0.000000144 V 15:45:00 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000835 Vs 15:45:17 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000289 V 15:45:17 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000816 Vs 15:45:34 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000000 V 15:45:34 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000816 Vs 15:45:51 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 15:45:51 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000885 Vs 15:46:08 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000000 V 15:46:08 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000851 Vs 15:46:25 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000289 V 15:46:25 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000792 Vs 15:46:42 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000072 V 15:46:42 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000826 Vs 15:46:59 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000361 V 15:46:59 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000806 Vs 15:46:59 Integrated Voltage Average and RMS of Measurements X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000827 +- 0.000000011 Vs 15:46:59 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0004000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000000827 +- 0.000000011 Vs BL = 0.00206781 +- 0.00002659 Tm 15:46:59 Integrated Voltage Measurement... 15:47:16 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000000 V 15:47:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000211 Vs 15:47:33 Voltage Offset Correction: v_off_ini = -0.000000072 V, v_off_fin = 0.000000217 V 15:47:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000121 Vs 15:47:50 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000217 V 15:47:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000174 Vs 15:48:07 Voltage Offset Correction: v_off_ini = -0.000000072 V, v_off_fin = 0.000000217 V 15:48:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000111 Vs 15:48:24 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 15:48:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000190 Vs 15:48:41 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000217 V 15:48:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000146 Vs 15:48:57 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 15:48:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000151 Vs 15:49:14 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000361 V 15:49:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000178 Vs 15:49:31 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = -0.000000072 V 15:49:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000244 Vs 15:49:48 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000144 V 15:49:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000156 Vs 15:50:05 Voltage Offset Correction: v_off_ini = -0.000000072 V, v_off_fin = -0.000000072 V 15:50:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000205 Vs 15:50:22 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000144 V 15:50:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000175 Vs 15:50:39 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000144 V 15:50:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000242 Vs 15:50:56 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000217 V 15:50:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000177 Vs 15:50:56 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000177 +- 0.000000022 Vs 15:50:56 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000000177 +- 0.000000022 Vs BL = 0.00044284 +- 0.00005419 Tm 15:50:56 Integrated Voltage Measurement... 15:51:13 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 15:51:13 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000503 Vs 15:51:30 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000000 V 15:51:30 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000472 Vs 15:51:47 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000505 V 15:51:47 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000471 Vs 15:52:04 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 15:52:04 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000485 Vs 15:52:21 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000144 V 15:52:21 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000395 Vs 15:52:38 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000217 V 15:52:38 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000479 Vs 15:52:55 Voltage Offset Correction: v_off_ini = -0.000000072 V, v_off_fin = 0.000000144 V 15:52:55 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000433 Vs 15:53:12 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000217 V 15:53:12 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000502 Vs 15:53:29 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000361 V 15:53:29 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000503 Vs 15:53:46 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000289 V 15:53:46 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000438 Vs 15:54:03 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000144 V 15:54:03 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000429 Vs 15:54:20 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000144 V 15:54:20 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000514 Vs 15:54:37 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000144 V 15:54:37 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000415 Vs 15:54:54 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000361 V 15:54:54 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000460 Vs 15:54:54 Integrated Voltage Average and RMS of Measurements X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000464 +- 0.000000018 Vs 15:54:54 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0004000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000000464 +- 0.000000018 Vs BL = -0.00116070 +- 0.00004517 Tm 15:54:54 Integrated Voltage Measurement... 15:55:11 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000217 V 15:55:11 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001073 Vs 15:55:28 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000433 V 15:55:28 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001124 Vs 15:55:45 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000072 V 15:55:45 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001074 Vs 15:56:02 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000144 V 15:56:02 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001194 Vs 15:56:19 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000361 V 15:56:19 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001075 Vs 15:56:36 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000505 V 15:56:36 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001090 Vs 15:56:53 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000361 V 15:56:53 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001161 Vs 15:57:09 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000433 V 15:57:10 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001076 Vs 15:57:26 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000072 V 15:57:26 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001092 Vs 15:57:43 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000289 V 15:57:43 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001092 Vs 15:58:00 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000217 V 15:58:00 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001083 Vs 15:58:17 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000361 V 15:58:17 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001129 Vs 15:58:34 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = -0.000000072 V 15:58:34 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001003 Vs 15:58:51 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000433 V 15:58:51 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001100 Vs 15:58:51 Integrated Voltage Average and RMS of Measurements X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001097 +- 0.000000025 Vs 15:58:51 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0008000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000001097 +- 0.000000025 Vs BL = -0.00274364 +- 0.00006133 Tm 15:58:51 Integrated Voltage Measurement... 15:59:08 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000217 V 15:59:08 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001752 Vs 15:59:25 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000289 V 15:59:25 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001749 Vs 15:59:42 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000505 V 15:59:42 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001719 Vs 15:59:59 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000289 V 15:59:59 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001782 Vs 16:00:16 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000072 V 16:00:16 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001720 Vs 16:00:33 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000144 V 16:00:33 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001801 Vs 16:00:50 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000144 V 16:00:50 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001759 Vs 16:01:07 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000650 V 16:01:07 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001682 Vs 16:01:24 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = -0.000000072 V 16:01:24 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001705 Vs 16:01:41 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000072 V 16:01:41 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001784 Vs 16:01:58 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000144 V 16:01:58 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001704 Vs 16:02:15 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 16:02:15 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001741 Vs 16:02:31 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000072 V 16:02:31 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001693 Vs 16:02:48 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000433 V 16:02:48 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001722 Vs 16:02:48 Integrated Voltage Average and RMS of Measurements X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001737 +- 0.000000018 Vs 16:02:48 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0012000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000001737 +- 0.000000018 Vs BL = -0.00434188 +- 0.00004569 Tm 16:02:57 Integrated Voltage Measurement... 16:03:14 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000217 V 16:03:14 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002122 Vs 16:03:31 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000217 V 16:03:31 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002114 Vs 16:03:48 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000144 V 16:03:48 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002086 Vs 16:04:05 Voltage Offset Correction: v_off_ini = -0.000000072 V, v_off_fin = 0.000000072 V 16:04:05 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002013 Vs 16:04:22 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000144 V 16:04:22 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002088 Vs 16:04:39 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000433 V 16:04:39 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002091 Vs 16:04:56 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000361 V 16:04:56 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002050 Vs 16:05:13 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000217 V 16:05:13 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002071 Vs 16:05:30 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000144 V 16:05:30 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002079 Vs 16:05:46 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 16:05:46 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002154 Vs 16:06:03 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000433 V 16:06:03 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002077 Vs 16:06:20 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000000 V 16:06:20 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002025 Vs 16:06:37 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000361 V 16:06:37 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002080 Vs 16:06:54 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000361 V 16:06:54 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002087 Vs 16:06:54 Integrated Voltage Average and RMS of Measurements X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002081 +- 0.000000027 Vs 16:06:54 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0012000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000002081 +- 0.000000027 Vs BL = 0.00520314 +- 0.00006683 Tm 16:06:54 Integrated Voltage Measurement... 16:07:11 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000000 V 16:07:12 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001441 Vs 16:07:28 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 16:07:28 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001475 Vs 16:07:45 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000144 V 16:07:45 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001452 Vs 16:08:02 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000650 V 16:08:02 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001446 Vs 16:08:19 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000217 V 16:08:19 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001497 Vs 16:08:36 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000217 V 16:08:36 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001496 Vs 16:08:53 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000217 V 16:08:53 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001505 Vs 16:09:10 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000361 V 16:09:10 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001467 Vs 16:09:27 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000000 V 16:09:27 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001534 Vs 16:09:44 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000289 V 16:09:44 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001407 Vs 16:10:01 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000289 V 16:10:01 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001444 Vs 16:10:18 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000144 V 16:10:18 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001353 Vs 16:10:35 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 16:10:35 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001458 Vs 16:10:52 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000505 V 16:10:52 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001465 Vs 16:10:52 Integrated Voltage Average and RMS of Measurements X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001460 +- 0.000000029 Vs 16:10:52 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0008000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000001460 +- 0.000000029 Vs BL = 0.00364984 +- 0.00007320 Tm 16:10:52 Integrated Voltage Measurement... 16:11:09 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 16:11:09 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000794 Vs 16:11:26 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 16:11:26 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000785 Vs 16:11:43 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000433 V 16:11:43 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000827 Vs 16:12:00 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000144 V 16:12:00 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000805 Vs 16:12:17 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = -0.000000072 V 16:12:17 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000873 Vs 16:12:33 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000433 V 16:12:34 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000816 Vs 16:12:50 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000217 V 16:12:50 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000878 Vs 16:13:07 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000505 V 16:13:07 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000833 Vs 16:13:24 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000144 V 16:13:24 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000914 Vs 16:13:41 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000433 V 16:13:41 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000842 Vs 16:13:58 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000361 V 16:13:58 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000785 Vs 16:14:15 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000289 V 16:14:15 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000852 Vs 16:14:32 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000217 V 16:14:32 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000878 Vs 16:14:49 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000289 V 16:14:49 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000818 Vs 16:14:49 Integrated Voltage Average and RMS of Measurements X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000836 +- 0.000000027 Vs 16:14:49 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0004000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000000836 +- 0.000000027 Vs BL = 0.00208906 +- 0.00006811 Tm 16:14:49 Integrated Voltage Measurement... 16:15:06 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000144 V 16:15:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000122 Vs 16:15:23 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000289 V 16:15:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000206 Vs 16:15:40 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000000 V 16:15:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000205 Vs 16:15:57 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 16:15:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000229 Vs 16:16:14 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000433 V 16:16:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000226 Vs 16:16:31 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000361 V 16:16:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000227 Vs 16:16:48 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000144 V 16:16:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000201 Vs 16:17:05 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000289 V 16:17:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000183 Vs 16:17:22 Voltage Offset Correction: v_off_ini = -0.000000072 V, v_off_fin = -0.000000144 V 16:17:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000240 Vs 16:17:39 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000000 V 16:17:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000160 Vs 16:17:56 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = -0.000000289 V 16:17:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000230 Vs 16:18:13 Voltage Offset Correction: v_off_ini = -0.000000072 V, v_off_fin = 0.000000144 V 16:18:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000188 Vs 16:18:29 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = -0.000000144 V 16:18:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000248 Vs 16:18:46 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000217 V 16:18:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000106 Vs 16:18:46 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000198 +- 0.000000020 Vs 16:18:46 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000000198 +- 0.000000020 Vs BL = 0.00049473 +- 0.00005078 Tm 16:18:47 Integrated Voltage Measurement... 16:19:04 Voltage Offset Correction: v_off_ini = 0.000000000 V, v_off_fin = 0.000000000 V 16:19:04 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000467 Vs 16:19:21 Voltage Offset Correction: v_off_ini = 0.000000000 V, v_off_fin = 0.000000217 V 16:19:21 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000454 Vs 16:19:38 Voltage Offset Correction: v_off_ini = -0.000000072 V, v_off_fin = -0.000000000 V 16:19:38 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000449 Vs 16:19:54 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000144 V 16:19:54 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000512 Vs 16:20:11 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000144 V 16:20:11 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000510 Vs 16:20:28 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 16:20:28 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000469 Vs 16:20:45 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000000 V 16:20:45 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000406 Vs 16:21:02 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000433 V 16:21:02 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000423 Vs 16:21:19 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000144 V 16:21:19 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000494 Vs 16:21:36 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000144 V 16:21:36 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000462 Vs 16:21:53 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = -0.000000072 V 16:21:53 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000416 Vs 16:22:10 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000144 V 16:22:10 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000466 Vs 16:22:27 Voltage Offset Correction: v_off_ini = 0.000000000 V, v_off_fin = 0.000000217 V 16:22:27 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000454 Vs 16:22:44 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000361 V 16:22:44 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000467 Vs 16:22:44 Integrated Voltage Average and RMS of Measurements X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000461 +- 0.000000024 Vs 16:22:44 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0004000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000000461 +- 0.000000024 Vs BL = -0.00115179 +- 0.00005974 Tm 16:22:44 Integrated Voltage Measurement... 16:23:01 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000072 V 16:23:01 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001132 Vs 16:23:18 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000072 V 16:23:18 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001117 Vs 16:23:35 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000000 V 16:23:35 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001059 Vs 16:23:52 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000072 V 16:23:52 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001152 Vs 16:24:09 Voltage Offset Correction: v_off_ini = -0.000000072 V, v_off_fin = 0.000000000 V 16:24:09 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001057 Vs 16:24:26 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000289 V 16:24:26 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001092 Vs 16:24:43 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000072 V 16:24:43 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001112 Vs 16:25:00 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 16:25:00 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001126 Vs 16:25:17 Voltage Offset Correction: v_off_ini = 0.000000000 V, v_off_fin = 0.000000144 V 16:25:17 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001058 Vs 16:25:34 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000217 V 16:25:34 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001178 Vs 16:25:51 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000361 V 16:25:51 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001136 Vs 16:26:08 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 16:26:08 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001082 Vs 16:26:25 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000072 V 16:26:25 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001099 Vs 16:26:42 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000217 V 16:26:42 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001118 Vs 16:26:42 Integrated Voltage Average and RMS of Measurements X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001108 +- 0.000000015 Vs 16:26:42 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0008000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000001108 +- 0.000000015 Vs BL = -0.00277094 +- 0.00003834 Tm 16:26:42 Integrated Voltage Measurement... 16:26:59 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000217 V 16:26:59 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001699 Vs 16:27:16 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000072 V 16:27:16 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001744 Vs 16:27:33 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000144 V 16:27:33 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001763 Vs 16:27:50 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000144 V 16:27:50 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001770 Vs 16:28:07 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000217 V 16:28:07 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001783 Vs 16:28:23 Voltage Offset Correction: v_off_ini = 0.000000000 V, v_off_fin = 0.000000144 V 16:28:24 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001757 Vs 16:28:40 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000144 V 16:28:40 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001720 Vs 16:28:57 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000217 V 16:28:57 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001769 Vs 16:29:14 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000144 V 16:29:14 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001757 Vs 16:29:31 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000144 V 16:29:31 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001755 Vs 16:29:48 Voltage Offset Correction: v_off_ini = -0.000000072 V, v_off_fin = -0.000000072 V 16:29:48 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001702 Vs 16:30:05 Voltage Offset Correction: v_off_ini = -0.000000072 V, v_off_fin = 0.000000000 V 16:30:05 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001783 Vs 16:30:22 Voltage Offset Correction: v_off_ini = 0.000000000 V, v_off_fin = -0.000000144 V 16:30:22 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001685 Vs 16:30:39 Voltage Offset Correction: v_off_ini = -0.000000144 V, v_off_fin = 0.000000289 V 16:30:39 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001797 Vs 16:30:39 Integrated Voltage Average and RMS of Measurements X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001749 +- 0.000000015 Vs 16:30:39 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0012000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000001749 +- 0.000000015 Vs BL = -0.00437228 +- 0.00003875 Tm 16:31:00 Name = None, is zeroed