SLAC Magnetic Measurements Date: 12-10-2009 Time: 12:05:04 Project: E163 Magnet Type: quad Magnet Name: PMQ1 Serial Number: 1 Run Number: 12 Measurement Device: 1 wire Operator: sda Comment: Integrated Strength vs x at roll = +5 deg. Test Currents (A): 0.0 0.0 0.0 0.0 12:05:34 Name = None, is zeroed 12:05:34 Integrated Voltage Measurement... 12:05:51 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000505 V 12:05:51 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002050 Vs 12:06:08 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000217 V 12:06:08 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002060 Vs 12:06:25 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000433 V 12:06:25 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002020 Vs 12:06:42 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000144 V 12:06:42 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002055 Vs 12:06:59 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000361 V 12:06:59 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002032 Vs 12:07:16 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000217 V 12:07:16 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002086 Vs 12:07:33 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000217 V 12:07:33 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002131 Vs 12:07:50 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000217 V 12:07:50 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002099 Vs 12:08:07 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000144 V 12:08:07 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002104 Vs 12:08:24 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000217 V 12:08:24 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002097 Vs 12:08:41 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000144 V 12:08:41 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002056 Vs 12:08:58 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000144 V 12:08:58 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002057 Vs 12:09:15 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000289 V 12:09:15 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002094 Vs 12:09:31 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000361 V 12:09:31 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002112 Vs 12:09:32 Integrated Voltage Average and RMS of Measurements X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002075 +- 0.000000028 Vs 12:09:32 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0012000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000002075 +- 0.000000028 Vs BL = 0.00518773 +- 0.00006982 Tm 12:09:32 Integrated Voltage Measurement... 12:09:49 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000217 V 12:09:49 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001404 Vs 12:10:06 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000217 V 12:10:06 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001491 Vs 12:10:23 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000072 V 12:10:23 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001493 Vs 12:10:40 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000289 V 12:10:40 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001430 Vs 12:10:57 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000144 V 12:10:57 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001495 Vs 12:11:14 Voltage Offset Correction: v_off_ini = 0.000000000 V, v_off_fin = 0.000000144 V 12:11:14 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001463 Vs 12:11:30 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = -0.000000144 V 12:11:30 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001484 Vs 12:11:47 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000217 V 12:11:47 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001466 Vs 12:12:04 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000144 V 12:12:04 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001495 Vs 12:12:21 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000433 V 12:12:21 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001497 Vs 12:12:38 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000217 V 12:12:38 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001528 Vs 12:12:55 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000217 V 12:12:55 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001491 Vs 12:13:12 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000144 V 12:13:12 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001467 Vs 12:13:29 Voltage Offset Correction: v_off_ini = -0.000000072 V, v_off_fin = 0.000000000 V 12:13:29 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001440 Vs 12:13:29 Integrated Voltage Average and RMS of Measurements X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001475 +- 0.000000021 Vs 12:13:29 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0008000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000001475 +- 0.000000021 Vs BL = 0.00368653 +- 0.00005268 Tm 12:13:29 Integrated Voltage Measurement... 12:13:46 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000072 V 12:13:46 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000839 Vs 12:14:03 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000072 V 12:14:03 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000842 Vs 12:14:20 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000000 V 12:14:20 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000874 Vs 12:14:37 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000144 V 12:14:37 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000822 Vs 12:14:54 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000000 V 12:14:54 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000852 Vs 12:15:11 Voltage Offset Correction: v_off_ini = -0.000000144 V, v_off_fin = 0.000000144 V 12:15:11 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000770 Vs 12:15:28 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 12:15:28 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000775 Vs 12:15:45 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000217 V 12:15:45 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000831 Vs 12:16:02 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000361 V 12:16:02 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000781 Vs 12:16:19 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000505 V 12:16:19 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000809 Vs 12:16:36 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 12:16:36 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000869 Vs 12:16:53 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000144 V 12:16:53 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000797 Vs 12:17:10 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000217 V 12:17:10 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000867 Vs 12:17:27 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000000 V 12:17:27 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000773 Vs 12:17:27 Integrated Voltage Average and RMS of Measurements X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000822 +- 0.000000018 Vs 12:17:27 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0004000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000000822 +- 0.000000018 Vs BL = 0.00205414 +- 0.00004557 Tm 12:17:27 Integrated Voltage Measurement... 12:17:44 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000217 V 12:17:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000160 Vs 12:18:01 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000361 V 12:18:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000185 Vs 12:18:18 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000144 V 12:18:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000199 Vs 12:18:35 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000433 V 12:18:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000211 Vs 12:18:52 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000144 V 12:18:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000227 Vs 12:19:09 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000217 V 12:19:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000184 Vs 12:19:26 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000144 V 12:19:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000232 Vs 12:19:43 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000289 V 12:19:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000219 Vs 12:20:00 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000144 V 12:20:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000185 Vs 12:20:16 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 12:20:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000214 Vs 12:20:33 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000505 V 12:20:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000169 Vs 12:20:50 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 12:20:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000149 Vs 12:21:07 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000144 V 12:21:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000155 Vs 12:21:24 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000505 V 12:21:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000207 Vs 12:21:24 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000193 +- 0.000000021 Vs 12:21:24 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000000193 +- 0.000000021 Vs BL = 0.00048132 +- 0.00005256 Tm 12:21:24 Integrated Voltage Measurement... 12:21:41 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000578 V 12:21:42 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000554 Vs 12:21:58 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000433 V 12:21:58 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000432 Vs 12:22:15 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000289 V 12:22:15 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000452 Vs 12:22:32 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000433 V 12:22:32 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000464 Vs 12:22:49 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000361 V 12:22:49 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000491 Vs 12:23:06 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 12:23:06 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000469 Vs 12:23:23 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000289 V 12:23:23 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000434 Vs 12:23:40 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000433 V 12:23:40 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000485 Vs 12:23:57 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000433 V 12:23:57 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000482 Vs 12:24:14 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000433 V 12:24:14 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000425 Vs 12:24:31 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 12:24:31 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000413 Vs 12:24:48 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000433 V 12:24:48 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000497 Vs 12:25:05 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000578 V 12:25:05 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000469 Vs 12:25:22 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 12:25:22 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000477 Vs 12:25:22 Integrated Voltage Average and RMS of Measurements X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000467 +- 0.000000014 Vs 12:25:22 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0004000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000000467 +- 0.000000014 Vs BL = -0.00116875 +- 0.00003495 Tm 12:25:22 Integrated Voltage Measurement... 12:25:39 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000289 V 12:25:39 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001177 Vs 12:25:56 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 12:25:56 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001129 Vs 12:26:13 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000217 V 12:26:13 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001088 Vs 12:26:30 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000072 V 12:26:30 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001145 Vs 12:26:47 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000217 V 12:26:47 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001133 Vs 12:27:04 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000361 V 12:27:04 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001084 Vs 12:27:21 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000433 V 12:27:21 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001169 Vs 12:27:38 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 12:27:38 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001065 Vs 12:27:54 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000144 V 12:27:54 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001087 Vs 12:28:11 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000433 V 12:28:11 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001114 Vs 12:28:28 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000217 V 12:28:28 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001107 Vs 12:28:45 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000361 V 12:28:45 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001096 Vs 12:29:02 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 12:29:02 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001200 Vs 12:29:19 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 12:29:19 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001148 Vs 12:29:19 Integrated Voltage Average and RMS of Measurements X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001124 +- 0.000000026 Vs 12:29:19 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0008000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000001124 +- 0.000000026 Vs BL = -0.00281076 +- 0.00006510 Tm 12:29:19 Integrated Voltage Measurement... 12:29:36 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000361 V 12:29:36 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001792 Vs 12:29:53 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000433 V 12:29:53 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001749 Vs 12:30:10 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 12:30:10 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001778 Vs 12:30:27 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000578 V 12:30:27 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001669 Vs 12:30:44 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000433 V 12:30:44 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001710 Vs 12:31:01 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000505 V 12:31:01 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001692 Vs 12:31:18 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000578 V 12:31:18 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001761 Vs 12:31:35 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 12:31:35 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001686 Vs 12:31:52 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000433 V 12:31:52 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001765 Vs 12:32:09 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000794 V 12:32:09 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001669 Vs 12:32:26 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000361 V 12:32:26 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001670 Vs 12:32:43 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000361 V 12:32:43 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001758 Vs 12:33:00 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000361 V 12:33:00 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001694 Vs 12:33:17 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000217 V 12:33:17 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001739 Vs 12:33:17 Integrated Voltage Average and RMS of Measurements X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001724 +- 0.000000020 Vs 12:33:17 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0012000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000001724 +- 0.000000020 Vs BL = -0.00430946 +- 0.00005081 Tm 12:33:25 Integrated Voltage Measurement... 12:33:43 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000505 V 12:33:43 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002063 Vs 12:33:59 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000578 V 12:33:59 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002070 Vs 12:34:16 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000505 V 12:34:16 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002063 Vs 12:34:33 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 12:34:33 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002051 Vs 12:34:50 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 12:34:50 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002081 Vs 12:35:07 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000505 V 12:35:07 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002082 Vs 12:35:24 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 12:35:24 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002071 Vs 12:35:41 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000361 V 12:35:41 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002044 Vs 12:35:58 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000505 V 12:35:58 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002073 Vs 12:36:15 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000361 V 12:36:15 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002063 Vs 12:36:32 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000361 V 12:36:32 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002049 Vs 12:36:49 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000505 V 12:36:49 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002071 Vs 12:37:06 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000433 V 12:37:06 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002064 Vs 12:37:23 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000433 V 12:37:23 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002057 Vs 12:37:23 Integrated Voltage Average and RMS of Measurements X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002064 +- 0.000000008 Vs 12:37:23 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0012000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000002064 +- 0.000000008 Vs BL = 0.00516116 +- 0.00001983 Tm 12:37:23 Integrated Voltage Measurement... 12:37:40 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000433 V 12:37:40 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001404 Vs 12:37:57 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000722 V 12:37:57 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001514 Vs 12:38:14 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000217 V 12:38:14 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001444 Vs 12:38:31 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000505 V 12:38:31 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001506 Vs 12:38:48 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000289 V 12:38:48 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001454 Vs 12:39:05 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000433 V 12:39:05 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001474 Vs 12:39:22 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000144 V 12:39:22 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001477 Vs 12:39:39 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 12:39:39 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001476 Vs 12:39:55 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 12:39:55 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001447 Vs 12:40:12 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000361 V 12:40:12 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001446 Vs 12:40:29 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000433 V 12:40:29 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001430 Vs 12:40:46 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000650 V 12:40:46 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001461 Vs 12:41:03 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000217 V 12:41:03 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001466 Vs 12:41:20 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000433 V 12:41:20 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001432 Vs 12:41:20 Integrated Voltage Average and RMS of Measurements X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001459 +- 0.000000012 Vs 12:41:20 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0008000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000001459 +- 0.000000012 Vs BL = 0.00364857 +- 0.00003051 Tm 12:41:20 Integrated Voltage Measurement... 12:41:37 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000144 V 12:41:37 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000809 Vs 12:41:54 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000433 V 12:41:54 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000832 Vs 12:42:11 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 12:42:11 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000850 Vs 12:42:28 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000217 V 12:42:28 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000799 Vs 12:42:45 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000361 V 12:42:45 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000837 Vs 12:43:02 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000217 V 12:43:02 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000852 Vs 12:43:19 Voltage Offset Correction: v_off_ini = 0.000000000 V, v_off_fin = 0.000000144 V 12:43:19 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000840 Vs 12:43:36 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000144 V 12:43:36 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000826 Vs 12:43:53 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 12:43:53 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000800 Vs 12:44:10 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000217 V 12:44:10 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000774 Vs 12:44:27 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000289 V 12:44:27 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000819 Vs 12:44:44 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000144 V 12:44:44 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000815 Vs 12:45:01 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 12:45:01 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000794 Vs 12:45:18 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000144 V 12:45:18 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000769 Vs 12:45:18 Integrated Voltage Average and RMS of Measurements X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000815 +- 0.000000022 Vs 12:45:18 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0004000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000000815 +- 0.000000022 Vs BL = 0.00203860 +- 0.00005377 Tm 12:45:18 Integrated Voltage Measurement... 12:45:35 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000000 V 12:45:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000231 Vs 12:45:52 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000361 V 12:45:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000182 Vs 12:46:09 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000217 V 12:46:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000216 Vs 12:46:26 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000361 V 12:46:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000173 Vs 12:46:43 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000144 V 12:46:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000202 Vs 12:47:00 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000217 V 12:47:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000142 Vs 12:47:17 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000217 V 12:47:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000163 Vs 12:47:33 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000072 V 12:47:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000175 Vs 12:47:50 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 12:47:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000172 Vs 12:48:07 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 12:48:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000173 Vs 12:48:24 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000000 V 12:48:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000259 Vs 12:48:41 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000433 V 12:48:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000137 Vs 12:48:58 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 12:48:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000200 Vs 12:49:15 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000433 V 12:49:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000199 Vs 12:49:15 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000187 +- 0.000000015 Vs 12:49:15 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000000187 +- 0.000000015 Vs BL = 0.00046859 +- 0.00003650 Tm 12:49:15 Integrated Voltage Measurement... 12:49:32 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000217 V 12:49:32 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000469 Vs 12:49:49 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000289 V 12:49:49 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000450 Vs 12:50:06 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000144 V 12:50:06 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000458 Vs 12:50:23 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 12:50:23 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000461 Vs 12:50:40 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000217 V 12:50:40 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000449 Vs 12:50:57 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000433 V 12:50:57 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000504 Vs 12:51:14 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 12:51:14 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000503 Vs 12:51:31 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000217 V 12:51:31 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000536 Vs 12:51:48 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 12:51:48 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000460 Vs 12:52:05 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 12:52:05 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000493 Vs 12:52:22 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000433 V 12:52:22 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000442 Vs 12:52:39 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000144 V 12:52:39 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000555 Vs 12:52:55 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000144 V 12:52:56 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000467 Vs 12:53:12 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 12:53:12 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000497 Vs 12:53:12 Integrated Voltage Average and RMS of Measurements X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000482 +- 0.000000020 Vs 12:53:13 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0004000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000000482 +- 0.000000020 Vs BL = -0.00120417 +- 0.00004959 Tm 12:53:13 Integrated Voltage Measurement... 12:53:30 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000217 V 12:53:30 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001132 Vs 12:53:47 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000217 V 12:53:47 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001139 Vs 12:54:04 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000217 V 12:54:04 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001092 Vs 12:54:20 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 12:54:20 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001133 Vs 12:54:37 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000361 V 12:54:37 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001101 Vs 12:54:54 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000505 V 12:54:54 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001153 Vs 12:55:11 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 12:55:11 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001156 Vs 12:55:28 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000505 V 12:55:28 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001122 Vs 12:55:45 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 12:55:45 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001139 Vs 12:56:02 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 12:56:02 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001099 Vs 12:56:19 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000361 V 12:56:19 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001123 Vs 12:56:36 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 12:56:36 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001064 Vs 12:56:53 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000361 V 12:56:53 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001082 Vs 12:57:10 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000650 V 12:57:10 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001123 Vs 12:57:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001118 +- 0.000000016 Vs 12:57:10 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0008000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000001118 +- 0.000000016 Vs BL = -0.00279598 +- 0.00003907 Tm 12:57:10 Integrated Voltage Measurement... 12:57:27 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 12:57:27 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001750 Vs 12:57:44 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 12:57:44 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001779 Vs 12:58:01 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000433 V 12:58:01 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001740 Vs 12:58:18 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 12:58:18 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001702 Vs 12:58:35 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 12:58:35 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001763 Vs 12:58:52 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000361 V 12:58:52 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001724 Vs 12:59:09 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000217 V 12:59:09 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001682 Vs 12:59:26 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000361 V 12:59:26 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001725 Vs 12:59:42 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000433 V 12:59:43 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001766 Vs 12:59:59 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000578 V 12:59:59 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001684 Vs 13:00:16 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000505 V 13:00:16 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001714 Vs 13:00:33 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 13:00:33 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001689 Vs 13:00:50 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 13:00:50 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001699 Vs 13:01:07 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000433 V 13:01:07 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001734 Vs 13:01:07 Integrated Voltage Average and RMS of Measurements X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001725 +- 0.000000021 Vs 13:01:07 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0012000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000001725 +- 0.000000021 Vs BL = -0.00431266 +- 0.00005169 Tm 13:01:16 Integrated Voltage Measurement... 13:01:33 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000361 V 13:01:33 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002081 Vs 13:01:50 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000361 V 13:01:50 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002077 Vs 13:02:07 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000433 V 13:02:07 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002061 Vs 13:02:24 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 13:02:24 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002046 Vs 13:02:41 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 13:02:41 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002100 Vs 13:02:58 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 13:02:58 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002078 Vs 13:03:15 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 13:03:15 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002070 Vs 13:03:31 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000578 V 13:03:31 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002058 Vs 13:03:48 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000433 V 13:03:48 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002071 Vs 13:04:05 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000505 V 13:04:05 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002099 Vs 13:04:22 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 13:04:22 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002085 Vs 13:04:39 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000217 V 13:04:39 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002005 Vs 13:04:56 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000144 V 13:04:56 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002119 Vs 13:05:13 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000217 V 13:05:13 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002037 Vs 13:05:13 Integrated Voltage Average and RMS of Measurements X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002070 +- 0.000000015 Vs 13:05:13 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0012000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000002070 +- 0.000000015 Vs BL = 0.00517617 +- 0.00003873 Tm 13:05:13 Integrated Voltage Measurement... 13:05:30 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000361 V 13:05:30 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001423 Vs 13:05:47 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000361 V 13:05:47 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001423 Vs 13:06:04 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000361 V 13:06:04 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001468 Vs 13:06:21 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000217 V 13:06:21 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001478 Vs 13:06:38 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000289 V 13:06:38 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001462 Vs 13:06:55 Voltage Offset Correction: v_off_ini = -0.000000072 V, v_off_fin = 0.000000289 V 13:06:55 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001419 Vs 13:07:12 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 13:07:12 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001486 Vs 13:07:29 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 13:07:29 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001508 Vs 13:07:46 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000433 V 13:07:46 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001430 Vs 13:08:03 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000072 V 13:08:03 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001456 Vs 13:08:20 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000217 V 13:08:20 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001482 Vs 13:08:37 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000289 V 13:08:37 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001425 Vs 13:08:53 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000361 V 13:08:54 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001457 Vs 13:09:10 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000650 V 13:09:10 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001494 Vs 13:09:10 Integrated Voltage Average and RMS of Measurements X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001458 +- 0.000000023 Vs 13:09:10 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0008000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000001458 +- 0.000000023 Vs BL = 0.00364457 +- 0.00005842 Tm 13:09:11 Integrated Voltage Measurement... 13:09:28 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000072 V 13:09:28 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000876 Vs 13:09:45 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000289 V 13:09:45 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000760 Vs 13:10:01 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000505 V 13:10:02 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000838 Vs 13:10:18 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000217 V 13:10:18 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000740 Vs 13:10:35 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000361 V 13:10:35 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000817 Vs 13:10:52 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000505 V 13:10:52 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000824 Vs 13:11:09 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000144 V 13:11:09 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000865 Vs 13:11:26 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000144 V 13:11:26 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000809 Vs 13:11:43 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000217 V 13:11:43 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000884 Vs 13:12:00 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000289 V 13:12:00 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000742 Vs 13:12:17 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000505 V 13:12:17 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000808 Vs 13:12:34 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000650 V 13:12:34 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000804 Vs 13:12:51 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000217 V 13:12:51 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000866 Vs 13:13:08 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000361 V 13:13:08 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000795 Vs 13:13:08 Integrated Voltage Average and RMS of Measurements X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000816 +- 0.000000015 Vs 13:13:08 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0004000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000000816 +- 0.000000015 Vs BL = 0.00204088 +- 0.00003655 Tm 13:13:08 Integrated Voltage Measurement... 13:13:25 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000433 V 13:13:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000158 Vs 13:13:42 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000433 V 13:13:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000182 Vs 13:13:59 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000578 V 13:13:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000144 Vs 13:14:16 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000505 V 13:14:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000178 Vs 13:14:33 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 13:14:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000146 Vs 13:14:50 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 13:14:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000201 Vs 13:15:07 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000578 V 13:15:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000143 Vs 13:15:24 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000505 V 13:15:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000216 Vs 13:15:41 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000361 V 13:15:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000225 Vs 13:15:58 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000578 V 13:15:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000187 Vs 13:16:14 Voltage Offset Correction: v_off_ini = 0.000000794 V, v_off_fin = 0.000000505 V 13:16:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000122 Vs 13:16:31 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000794 V 13:16:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000269 Vs 13:16:48 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 13:16:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000185 Vs 13:17:05 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000505 V 13:17:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000183 Vs 13:17:05 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000181 +- 0.000000014 Vs 13:17:05 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000000181 +- 0.000000014 Vs BL = 0.00045360 +- 0.00003535 Tm 13:17:05 Integrated Voltage Measurement... 13:17:22 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 13:17:22 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000497 Vs 13:17:39 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000361 V 13:17:39 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000474 Vs 13:17:56 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000289 V 13:17:56 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000464 Vs 13:18:13 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000650 V 13:18:13 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000454 Vs 13:18:30 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 13:18:30 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000464 Vs 13:18:47 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000433 V 13:18:47 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000438 Vs 13:19:04 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000144 V 13:19:04 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000425 Vs 13:19:21 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 13:19:21 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000461 Vs 13:19:38 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000505 V 13:19:38 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000491 Vs 13:19:55 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 13:19:55 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000470 Vs 13:20:12 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000578 V 13:20:12 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000554 Vs 13:20:29 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 13:20:29 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000466 Vs 13:20:46 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000361 V 13:20:46 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000525 Vs 13:21:03 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000289 V 13:21:03 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000516 Vs 13:21:03 Integrated Voltage Average and RMS of Measurements X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000478 +- 0.000000027 Vs 13:21:03 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0004000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000000478 +- 0.000000027 Vs BL = -0.00119600 +- 0.00006792 Tm 13:21:03 Integrated Voltage Measurement... 13:21:20 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000289 V 13:21:20 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001061 Vs 13:21:37 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000217 V 13:21:37 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001146 Vs 13:21:54 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000000 V 13:21:54 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001095 Vs 13:22:11 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000578 V 13:22:11 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001071 Vs 13:22:28 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000433 V 13:22:28 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001087 Vs 13:22:45 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000650 V 13:22:45 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001092 Vs 13:23:02 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000144 V 13:23:02 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001114 Vs 13:23:18 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 13:23:19 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001116 Vs 13:23:35 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000144 V 13:23:35 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001048 Vs 13:23:52 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000144 V 13:23:52 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001083 Vs 13:24:09 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000505 V 13:24:09 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001110 Vs 13:24:26 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 13:24:26 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001120 Vs 13:24:43 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000433 V 13:24:43 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001107 Vs 13:25:00 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000217 V 13:25:00 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001154 Vs 13:25:00 Integrated Voltage Average and RMS of Measurements X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001100 +- 0.000000021 Vs 13:25:00 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0008000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000001100 +- 0.000000021 Vs BL = -0.00275085 +- 0.00005182 Tm 13:25:00 Integrated Voltage Measurement... 13:25:17 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000289 V 13:25:17 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001755 Vs 13:25:34 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000505 V 13:25:34 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001772 Vs 13:25:51 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000217 V 13:25:51 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001673 Vs 13:26:08 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000361 V 13:26:08 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001767 Vs 13:26:25 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000144 V 13:26:25 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001673 Vs 13:26:42 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000505 V 13:26:42 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001758 Vs 13:26:59 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000505 V 13:26:59 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001730 Vs 13:27:16 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000433 V 13:27:16 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001736 Vs 13:27:33 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000289 V 13:27:33 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001702 Vs 13:27:50 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000433 V 13:27:50 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001706 Vs 13:28:07 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000433 V 13:28:07 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001782 Vs 13:28:24 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000433 V 13:28:24 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001762 Vs 13:28:41 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000433 V 13:28:41 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001757 Vs 13:28:57 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000578 V 13:28:58 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001693 Vs 13:28:58 Integrated Voltage Average and RMS of Measurements X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001733 +- 0.000000023 Vs 13:28:58 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0012000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000001733 +- 0.000000023 Vs BL = -0.00433317 +- 0.00005841 Tm 13:29:06 Integrated Voltage Measurement... 13:29:23 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000433 V 13:29:23 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002094 Vs 13:29:40 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000650 V 13:29:40 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002072 Vs 13:29:57 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000433 V 13:29:57 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002085 Vs 13:30:14 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000433 V 13:30:14 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002058 Vs 13:30:31 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000505 V 13:30:31 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002069 Vs 13:30:48 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 13:30:48 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002101 Vs 13:31:05 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000578 V 13:31:05 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002039 Vs 13:31:22 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 13:31:22 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002068 Vs 13:31:39 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000361 V 13:31:39 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002028 Vs 13:31:56 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000433 V 13:31:56 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002062 Vs 13:32:12 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000361 V 13:32:12 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002078 Vs 13:32:29 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000722 V 13:32:29 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002083 Vs 13:32:46 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000433 V 13:32:46 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002052 Vs 13:33:03 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000361 V 13:33:03 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002077 Vs 13:33:03 Integrated Voltage Average and RMS of Measurements X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002069 +- 0.000000014 Vs 13:33:03 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0012000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000002069 +- 0.000000014 Vs BL = 0.00517237 +- 0.00003595 Tm 13:33:03 Integrated Voltage Measurement... 13:33:20 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 13:33:20 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001457 Vs 13:33:37 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000289 V 13:33:37 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001437 Vs 13:33:54 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 13:33:54 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001452 Vs 13:34:11 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000361 V 13:34:11 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001457 Vs 13:34:28 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000144 V 13:34:28 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001526 Vs 13:34:45 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000505 V 13:34:45 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001494 Vs 13:35:02 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000217 V 13:35:02 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001457 Vs 13:35:19 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 13:35:19 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001482 Vs 13:35:36 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000361 V 13:35:36 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001472 Vs 13:35:53 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000578 V 13:35:53 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001511 Vs 13:36:10 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000433 V 13:36:10 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001438 Vs 13:36:27 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000144 V 13:36:27 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001396 Vs 13:36:44 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 13:36:44 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001427 Vs 13:37:01 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000578 V 13:37:01 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001442 Vs 13:37:01 Integrated Voltage Average and RMS of Measurements X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001461 +- 0.000000030 Vs 13:37:01 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0008000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000001461 +- 0.000000030 Vs BL = 0.00365146 +- 0.00007491 Tm 13:37:01 Integrated Voltage Measurement... 13:37:18 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000361 V 13:37:18 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000859 Vs 13:37:35 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000361 V 13:37:35 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000803 Vs 13:37:52 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000289 V 13:37:52 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000875 Vs 13:38:09 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000433 V 13:38:09 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000817 Vs 13:38:26 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000217 V 13:38:26 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000846 Vs 13:38:43 Voltage Offset Correction: v_off_ini = 0.000000000 V, v_off_fin = 0.000000361 V 13:38:43 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000769 Vs 13:39:00 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = -0.000000144 V 13:39:00 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000870 Vs 13:39:17 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000578 V 13:39:17 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000799 Vs 13:39:33 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000217 V 13:39:34 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000859 Vs 13:39:50 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000505 V 13:39:50 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000817 Vs 13:40:07 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 13:40:07 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000765 Vs 13:40:24 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000505 V 13:40:24 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000850 Vs 13:40:41 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000217 V 13:40:41 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000884 Vs 13:40:58 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000722 V 13:40:58 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000868 Vs 13:40:58 Integrated Voltage Average and RMS of Measurements X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000834 +- 0.000000022 Vs 13:40:58 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0004000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000000834 +- 0.000000022 Vs BL = 0.00208579 +- 0.00005439 Tm 13:40:58 Integrated Voltage Measurement... 13:41:15 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000578 V 13:41:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000095 Vs 13:41:32 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000433 V 13:41:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000195 Vs 13:41:49 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000361 V 13:41:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000182 Vs 13:42:06 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000433 V 13:42:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000205 Vs 13:42:23 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000433 V 13:42:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000158 Vs 13:42:40 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000505 V 13:42:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000233 Vs 13:42:57 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 13:42:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000158 Vs 13:43:14 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000361 V 13:43:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000210 Vs 13:43:31 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000289 V 13:43:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000138 Vs 13:43:48 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000361 V 13:43:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000216 Vs 13:44:05 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000289 V 13:44:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000211 Vs 13:44:22 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000578 V 13:44:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000173 Vs 13:44:39 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000361 V 13:44:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000138 Vs 13:44:55 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000361 V 13:44:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000170 Vs 13:44:56 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000177 +- 0.000000019 Vs 13:44:56 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000000177 +- 0.000000019 Vs BL = 0.00044299 +- 0.00004693 Tm 13:44:56 Integrated Voltage Measurement... 13:45:13 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000072 V 13:45:13 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000426 Vs 13:45:30 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000289 V 13:45:30 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000488 Vs 13:45:47 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 13:45:47 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000503 Vs 13:46:04 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000433 V 13:46:04 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000454 Vs 13:46:20 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000433 V 13:46:20 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000443 Vs 13:46:37 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000289 V 13:46:37 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000475 Vs 13:46:54 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000289 V 13:46:54 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000427 Vs 13:47:11 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000433 V 13:47:11 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000485 Vs 13:47:28 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000289 V 13:47:28 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000437 Vs 13:47:45 Voltage Offset Correction: v_off_ini = 0.000000794 V, v_off_fin = 0.000000794 V 13:47:45 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000394 Vs 13:48:02 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000361 V 13:48:02 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000446 Vs 13:48:19 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000578 V 13:48:19 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000453 Vs 13:48:36 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000217 V 13:48:36 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000461 Vs 13:48:53 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 13:48:53 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000441 Vs 13:48:53 Integrated Voltage Average and RMS of Measurements X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000452 +- 0.000000017 Vs 13:48:53 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0004000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000000452 +- 0.000000017 Vs BL = -0.00113105 +- 0.00004365 Tm 13:48:53 Integrated Voltage Measurement... 13:49:10 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000361 V 13:49:10 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001169 Vs 13:49:27 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000144 V 13:49:27 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001151 Vs 13:49:44 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 13:49:44 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001107 Vs 13:50:01 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 13:50:01 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001096 Vs 13:50:18 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000217 V 13:50:18 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001095 Vs 13:50:35 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 13:50:35 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001117 Vs 13:50:52 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 13:50:52 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001088 Vs 13:51:09 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 13:51:09 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001074 Vs 13:51:26 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000505 V 13:51:26 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001119 Vs 13:51:43 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000217 V 13:51:43 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001196 Vs 13:52:00 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000361 V 13:52:00 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001167 Vs 13:52:16 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000433 V 13:52:16 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001117 Vs 13:52:33 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000433 V 13:52:33 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001128 Vs 13:52:50 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000505 V 13:52:50 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001152 Vs 13:52:50 Integrated Voltage Average and RMS of Measurements X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001127 +- 0.000000028 Vs 13:52:50 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0008000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000001127 +- 0.000000028 Vs BL = -0.00281727 +- 0.00007097 Tm 13:52:50 Integrated Voltage Measurement... 13:53:08 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000144 V 13:53:08 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001697 Vs 13:53:25 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 13:53:25 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001675 Vs 13:53:41 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 13:53:42 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001690 Vs 13:53:58 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000505 V 13:53:58 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001725 Vs 13:54:15 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000650 V 13:54:15 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001750 Vs 13:54:32 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 13:54:32 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001752 Vs 13:54:49 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000144 V 13:54:49 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001735 Vs 13:55:06 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000433 V 13:55:06 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001662 Vs 13:55:23 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000289 V 13:55:23 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001719 Vs 13:55:40 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000144 V 13:55:40 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001803 Vs 13:55:57 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000578 V 13:55:57 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001738 Vs 13:56:14 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000578 V 13:56:14 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001686 Vs 13:56:31 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 13:56:31 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001750 Vs 13:56:48 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000650 V 13:56:48 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001690 Vs 13:56:48 Integrated Voltage Average and RMS of Measurements X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001719 +- 0.000000025 Vs 13:56:48 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0012000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000001719 +- 0.000000025 Vs BL = -0.00429869 +- 0.00006343 Tm 13:57:08 Name = None, is zeroed