SLAC Magnetic Measurements Date: 12-10-2009 Time: 08:49:36 Project: E163 Magnet Type: quad Magnet Name: PMQ1 Serial Number: 1 Run Number: 11 Measurement Device: 1 wire Operator: sda Comment: Integrated Strength vs x at roll = -5 deg. Test Currents (A): 0.0 0.0 0.0 0.0 08:50:07 Name = None, is zeroed 08:50:07 Integrated Voltage Measurement... 08:50:25 Voltage Offset Correction: v_off_ini = 0.000000794 V, v_off_fin = 0.000000794 V 08:50:25 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001921 Vs 08:50:41 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 08:50:41 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002012 Vs 08:50:58 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000217 V 08:50:58 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002049 Vs 08:51:15 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000144 V 08:51:15 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001956 Vs 08:51:32 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000217 V 08:51:32 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001993 Vs 08:51:49 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000072 V 08:51:49 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001943 Vs 08:52:06 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000217 V 08:52:06 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002036 Vs 08:52:23 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000578 V 08:52:23 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001982 Vs 08:52:40 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000144 V 08:52:40 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002013 Vs 08:52:57 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000217 V 08:52:57 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001987 Vs 08:53:14 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000072 V 08:53:14 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001975 Vs 08:53:31 Voltage Offset Correction: v_off_ini = -0.000000072 V, v_off_fin = 0.000000000 V 08:53:31 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001886 Vs 08:53:48 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000217 V 08:53:48 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001981 Vs 08:54:05 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000433 V 08:54:05 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001995 Vs 08:54:05 Integrated Voltage Average and RMS of Measurements X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001981 +- 0.000000026 Vs 08:54:05 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0012000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000001981 +- 0.000000026 Vs BL = 0.00495155 +- 0.00006404 Tm 08:54:05 Integrated Voltage Measurement... 08:54:22 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000144 V 08:54:22 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001304 Vs 08:54:39 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000144 V 08:54:39 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001325 Vs 08:54:56 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 08:54:56 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001320 Vs 08:55:13 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000289 V 08:55:13 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001339 Vs 08:55:30 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000361 V 08:55:30 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001330 Vs 08:55:47 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000289 V 08:55:47 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001325 Vs 08:56:04 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 08:56:04 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001306 Vs 08:56:21 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000000 V 08:56:21 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001291 Vs 08:56:38 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 08:56:38 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001285 Vs 08:56:55 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000361 V 08:56:55 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001300 Vs 08:57:12 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000144 V 08:57:12 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001325 Vs 08:57:29 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000433 V 08:57:29 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001374 Vs 08:57:45 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000144 V 08:57:46 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001357 Vs 08:58:02 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000144 V 08:58:03 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001303 Vs 08:58:03 Integrated Voltage Average and RMS of Measurements X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001320 +- 0.000000018 Vs 08:58:03 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0008000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000001320 +- 0.000000018 Vs BL = 0.00330077 +- 0.00004621 Tm 08:58:03 Integrated Voltage Measurement... 08:58:20 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000217 V 08:58:20 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000656 Vs 08:58:37 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000217 V 08:58:37 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000710 Vs 08:58:54 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000217 V 08:58:54 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000718 Vs 08:59:11 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000289 V 08:59:11 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000673 Vs 08:59:27 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 08:59:27 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000720 Vs 08:59:44 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000217 V 08:59:44 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000696 Vs 09:00:01 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000144 V 09:00:01 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000705 Vs 09:00:18 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000217 V 09:00:18 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000735 Vs 09:00:35 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = -0.000000072 V 09:00:35 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000752 Vs 09:00:52 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 09:00:52 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000710 Vs 09:01:09 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000144 V 09:01:09 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000716 Vs 09:01:26 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 09:01:26 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000681 Vs 09:01:43 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000578 V 09:01:43 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000665 Vs 09:02:00 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000361 V 09:02:00 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000718 Vs 09:02:00 Integrated Voltage Average and RMS of Measurements X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000704 +- 0.000000016 Vs 09:02:00 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0004000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000000704 +- 0.000000016 Vs BL = 0.00175978 +- 0.00003902 Tm 09:02:00 Integrated Voltage Measurement... 09:02:17 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000144 V 09:02:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000006 Vs 09:02:34 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 09:02:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000052 Vs 09:02:51 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 09:02:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000052 Vs 09:03:08 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000433 V 09:03:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000069 Vs 09:03:25 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000650 V 09:03:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = -0.000000039 Vs 09:03:42 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000289 V 09:03:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = 0.000000014 Vs 09:03:59 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 09:03:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000034 Vs 09:04:16 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000794 V 09:04:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000088 Vs 09:04:33 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000505 V 09:04:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = -0.000000021 Vs 09:04:50 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 09:04:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000083 Vs 09:05:07 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 09:05:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000018 Vs 09:05:24 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000650 V 09:05:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000088 Vs 09:05:41 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 09:05:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000052 Vs 09:05:58 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000794 V 09:05:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000053 Vs 09:05:58 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000037 +- 0.000000029 Vs 09:05:58 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000000037 +- 0.000000029 Vs BL = 0.00009301 +- 0.00007181 Tm 09:05:58 Integrated Voltage Measurement... 09:06:15 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000361 V 09:06:15 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000615 Vs 09:06:32 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000505 V 09:06:32 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000580 Vs 09:06:49 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000578 V 09:06:49 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000541 Vs 09:07:06 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000794 V 09:07:06 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000546 Vs 09:07:23 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000361 V 09:07:23 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000607 Vs 09:07:40 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000505 V 09:07:40 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000623 Vs 09:07:57 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000505 V 09:07:57 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000639 Vs 09:08:14 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000794 V 09:08:14 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000573 Vs 09:08:31 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000289 V 09:08:31 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000527 Vs 09:08:48 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000578 V 09:08:48 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000578 Vs 09:09:05 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000578 V 09:09:05 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000634 Vs 09:09:22 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000650 V 09:09:22 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000610 Vs 09:09:39 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000722 V 09:09:39 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000648 Vs 09:09:56 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000938 V 09:09:56 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000547 Vs 09:09:56 Integrated Voltage Average and RMS of Measurements X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000591 +- 0.000000028 Vs 09:09:56 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0004000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000000591 +- 0.000000028 Vs BL = -0.00147638 +- 0.00007070 Tm 09:09:56 Integrated Voltage Measurement... 09:10:13 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000650 V 09:10:13 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001213 Vs 09:10:30 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000650 V 09:10:30 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001199 Vs 09:10:47 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000650 V 09:10:47 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001178 Vs 09:11:04 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000578 V 09:11:04 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001192 Vs 09:11:21 Voltage Offset Correction: v_off_ini = 0.000000794 V, v_off_fin = 0.000000433 V 09:11:21 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001185 Vs 09:11:38 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000794 V 09:11:38 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001210 Vs 09:11:55 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000578 V 09:11:55 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001110 Vs 09:12:12 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 09:12:12 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001173 Vs 09:12:29 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000217 V 09:12:29 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001102 Vs 09:12:46 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000505 V 09:12:46 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001142 Vs 09:13:03 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000578 V 09:13:03 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001180 Vs 09:13:20 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000578 V 09:13:20 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001177 Vs 09:13:37 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000650 V 09:13:37 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001227 Vs 09:13:54 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000794 V 09:13:54 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001180 Vs 09:13:54 Integrated Voltage Average and RMS of Measurements X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001176 +- 0.000000030 Vs 09:13:54 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0008000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000001176 +- 0.000000030 Vs BL = -0.00294058 +- 0.00007467 Tm 09:13:54 Integrated Voltage Measurement... 09:14:11 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 09:14:12 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001919 Vs 09:14:28 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000505 V 09:14:29 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001873 Vs 09:14:45 Voltage Offset Correction: v_off_ini = 0.000000794 V, v_off_fin = 0.000000794 V 09:14:45 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001904 Vs 09:15:02 Voltage Offset Correction: v_off_ini = 0.000000794 V, v_off_fin = 0.000000578 V 09:15:02 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001831 Vs 09:15:19 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000578 V 09:15:19 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001822 Vs 09:15:36 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000578 V 09:15:36 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001847 Vs 09:15:53 Voltage Offset Correction: v_off_ini = 0.000000794 V, v_off_fin = 0.000000578 V 09:15:53 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001874 Vs 09:16:10 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000722 V 09:16:10 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001838 Vs 09:16:27 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000578 V 09:16:27 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001833 Vs 09:16:44 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000578 V 09:16:44 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001860 Vs 09:17:01 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000361 V 09:17:01 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001852 Vs 09:17:18 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000650 V 09:17:18 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001889 Vs 09:17:35 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000505 V 09:17:35 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001879 Vs 09:17:52 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000505 V 09:17:52 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001857 Vs 09:17:52 Integrated Voltage Average and RMS of Measurements X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001863 +- 0.000000018 Vs 09:17:52 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0012000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000001863 +- 0.000000018 Vs BL = -0.00465663 +- 0.00004554 Tm 09:18:00 Integrated Voltage Measurement... 09:18:18 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000433 V 09:18:18 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001998 Vs 09:18:35 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000505 V 09:18:35 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002008 Vs 09:18:52 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000722 V 09:18:52 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001982 Vs 09:19:08 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000433 V 09:19:09 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001987 Vs 09:19:26 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000217 V 09:19:26 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002008 Vs 09:19:42 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000650 V 09:19:43 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001989 Vs 09:19:59 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000361 V 09:20:00 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001981 Vs 09:20:16 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000578 V 09:20:16 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001999 Vs 09:20:33 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000505 V 09:20:33 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001980 Vs 09:20:50 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000650 V 09:20:50 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002017 Vs 09:21:07 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000722 V 09:21:07 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001985 Vs 09:21:24 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000650 V 09:21:24 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001996 Vs 09:21:41 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000217 V 09:21:41 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002015 Vs 09:21:58 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000578 V 09:21:58 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002014 Vs 09:21:58 Integrated Voltage Average and RMS of Measurements X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001997 +- 0.000000009 Vs 09:21:58 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0012000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000001997 +- 0.000000009 Vs BL = 0.00499293 +- 0.00002307 Tm 09:21:58 Integrated Voltage Measurement... 09:22:15 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000578 V 09:22:16 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001293 Vs 09:22:32 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000505 V 09:22:32 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001333 Vs 09:22:49 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000433 V 09:22:49 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001339 Vs 09:23:06 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000433 V 09:23:06 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001288 Vs 09:23:23 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000578 V 09:23:23 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001330 Vs 09:23:40 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000722 V 09:23:40 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001300 Vs 09:23:57 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000361 V 09:23:57 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001324 Vs 09:24:14 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000361 V 09:24:14 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001307 Vs 09:24:31 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000578 V 09:24:31 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001306 Vs 09:24:48 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000578 V 09:24:48 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001311 Vs 09:25:05 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000578 V 09:25:05 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001280 Vs 09:25:22 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 09:25:22 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001324 Vs 09:25:39 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000722 V 09:25:39 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001287 Vs 09:25:56 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000433 V 09:25:56 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001370 Vs 09:25:56 Integrated Voltage Average and RMS of Measurements X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001314 +- 0.000000007 Vs 09:25:56 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0008000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000001314 +- 0.000000007 Vs BL = 0.00328384 +- 0.00001834 Tm 09:25:56 Integrated Voltage Measurement... 09:26:13 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000505 V 09:26:13 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000676 Vs 09:26:30 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 09:26:30 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000716 Vs 09:26:47 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000578 V 09:26:47 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000727 Vs 09:27:04 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000578 V 09:27:04 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000703 Vs 09:27:21 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000361 V 09:27:21 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000682 Vs 09:27:38 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000578 V 09:27:38 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000706 Vs 09:27:55 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 09:27:55 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000710 Vs 09:28:12 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000578 V 09:28:12 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000717 Vs 09:28:29 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000433 V 09:28:29 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000649 Vs 09:28:46 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000361 V 09:28:46 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000671 Vs 09:29:03 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000361 V 09:29:03 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000689 Vs 09:29:20 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000505 V 09:29:20 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000759 Vs 09:29:37 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000289 V 09:29:37 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000724 Vs 09:29:54 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000505 V 09:29:54 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000727 Vs 09:29:54 Integrated Voltage Average and RMS of Measurements X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000704 +- 0.000000021 Vs 09:29:54 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0004000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000000704 +- 0.000000021 Vs BL = 0.00176007 +- 0.00005331 Tm 09:29:54 Integrated Voltage Measurement... 09:30:11 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000505 V 09:30:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000026 Vs 09:30:28 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000578 V 09:30:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000094 Vs 09:30:45 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 09:30:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000123 Vs 09:31:02 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000794 V 09:31:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000056 Vs 09:31:19 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000433 V 09:31:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000074 Vs 09:31:36 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000794 V 09:31:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000082 Vs 09:31:53 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000578 V 09:31:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000014 Vs 09:32:10 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000578 V 09:32:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = 0.000000006 Vs 09:32:27 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 09:32:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000007 Vs 09:32:43 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000650 V 09:32:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000065 Vs 09:33:00 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000361 V 09:33:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000029 Vs 09:33:17 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000650 V 09:33:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000053 Vs 09:33:34 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000361 V 09:33:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000103 Vs 09:33:51 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000505 V 09:33:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000016 Vs 09:33:51 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000053 +- 0.000000026 Vs 09:33:51 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000000053 +- 0.000000026 Vs BL = 0.00013200 +- 0.00006612 Tm 09:33:51 Integrated Voltage Measurement... 09:34:08 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000361 V 09:34:09 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000607 Vs 09:34:25 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000578 V 09:34:26 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000522 Vs 09:34:42 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000505 V 09:34:43 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000534 Vs 09:34:59 Voltage Offset Correction: v_off_ini = 0.000000794 V, v_off_fin = 0.000000794 V 09:34:59 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000562 Vs 09:35:16 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 09:35:16 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000613 Vs 09:35:33 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000505 V 09:35:33 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000602 Vs 09:35:50 Voltage Offset Correction: v_off_ini = 0.000000794 V, v_off_fin = 0.000000722 V 09:35:50 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000631 Vs 09:36:07 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000794 V 09:36:07 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000544 Vs 09:36:24 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000505 V 09:36:24 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000566 Vs 09:36:41 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000866 V 09:36:41 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000544 Vs 09:36:58 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000650 V 09:36:58 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000626 Vs 09:37:15 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000578 V 09:37:15 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000625 Vs 09:37:32 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000578 V 09:37:32 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000659 Vs 09:37:49 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000578 V 09:37:49 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000599 Vs 09:37:49 Integrated Voltage Average and RMS of Measurements X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000588 +- 0.000000031 Vs 09:37:49 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0004000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000000588 +- 0.000000031 Vs BL = -0.00147033 +- 0.00007709 Tm 09:37:49 Integrated Voltage Measurement... 09:38:07 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 09:38:07 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001212 Vs 09:38:24 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000650 V 09:38:24 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001150 Vs 09:38:41 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 09:38:41 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001173 Vs 09:38:57 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000505 V 09:38:58 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001271 Vs 09:39:14 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000794 V 09:39:15 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001180 Vs 09:39:31 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000794 V 09:39:32 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001205 Vs 09:39:48 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000578 V 09:39:48 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001131 Vs 09:40:05 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000361 V 09:40:05 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001217 Vs 09:40:22 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000578 V 09:40:22 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001161 Vs 09:40:39 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000650 V 09:40:39 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001122 Vs 09:40:56 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000578 V 09:40:56 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001230 Vs 09:41:13 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000722 V 09:41:13 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001162 Vs 09:41:30 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 09:41:30 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001215 Vs 09:41:47 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000794 V 09:41:47 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001226 Vs 09:41:47 Integrated Voltage Average and RMS of Measurements X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001190 +- 0.000000026 Vs 09:41:47 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0008000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000001190 +- 0.000000026 Vs BL = -0.00297414 +- 0.00006465 Tm 09:41:47 Integrated Voltage Measurement... 09:42:05 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000794 V 09:42:05 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001965 Vs 09:42:22 Voltage Offset Correction: v_off_ini = 0.000000794 V, v_off_fin = 0.000000794 V 09:42:22 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001842 Vs 09:42:38 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000361 V 09:42:39 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001860 Vs 09:42:56 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000433 V 09:42:56 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001890 Vs 09:43:13 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 09:43:13 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001859 Vs 09:43:29 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000650 V 09:43:30 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001858 Vs 09:43:47 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000361 V 09:43:47 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001894 Vs 09:44:04 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 09:44:04 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001871 Vs 09:44:20 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000433 V 09:44:21 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001861 Vs 09:44:37 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000433 V 09:44:38 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001835 Vs 09:44:54 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000578 V 09:44:55 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001880 Vs 09:45:11 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000361 V 09:45:11 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001904 Vs 09:45:28 Voltage Offset Correction: v_off_ini = 0.000000866 V, v_off_fin = 0.000000433 V 09:45:28 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001920 Vs 09:45:45 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000578 V 09:45:45 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001808 Vs 09:45:45 Integrated Voltage Average and RMS of Measurements X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001875 +- 0.000000018 Vs 09:45:45 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0012000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000001875 +- 0.000000018 Vs BL = -0.00468715 +- 0.00004508 Tm 09:45:54 Integrated Voltage Measurement... 09:46:11 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000289 V 09:46:11 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002018 Vs 09:46:28 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000505 V 09:46:28 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001980 Vs 09:46:45 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000217 V 09:46:45 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002006 Vs 09:47:02 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000361 V 09:47:02 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001958 Vs 09:47:19 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000072 V 09:47:19 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002105 Vs 09:47:36 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000361 V 09:47:36 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001975 Vs 09:47:53 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000289 V 09:47:53 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002036 Vs 09:48:10 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 09:48:10 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001965 Vs 09:48:27 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000361 V 09:48:27 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001994 Vs 09:48:44 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000578 V 09:48:44 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002061 Vs 09:49:01 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000505 V 09:49:01 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001982 Vs 09:49:18 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000361 V 09:49:18 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002013 Vs 09:49:35 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000217 V 09:49:35 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001972 Vs 09:49:52 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000433 V 09:49:52 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002006 Vs 09:49:52 Integrated Voltage Average and RMS of Measurements X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002005 +- 0.000000019 Vs 09:49:52 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0012000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000002005 +- 0.000000019 Vs BL = 0.00501241 +- 0.00004862 Tm 09:49:52 Integrated Voltage Measurement... 09:50:09 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000578 V 09:50:09 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001306 Vs 09:50:26 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000794 V 09:50:26 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001337 Vs 09:50:43 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000794 V 09:50:43 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001337 Vs 09:51:00 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000578 V 09:51:00 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001361 Vs 09:51:17 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 09:51:17 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001346 Vs 09:51:34 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000505 V 09:51:34 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001370 Vs 09:51:51 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 09:51:51 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001325 Vs 09:52:08 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000433 V 09:52:08 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001354 Vs 09:52:25 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 09:52:25 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001316 Vs 09:52:42 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000794 V 09:52:42 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001401 Vs 09:52:59 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 09:52:59 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001320 Vs 09:53:16 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000650 V 09:53:16 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001345 Vs 09:53:33 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000505 V 09:53:33 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001280 Vs 09:53:50 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000433 V 09:53:50 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001343 Vs 09:53:50 Integrated Voltage Average and RMS of Measurements X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001339 +- 0.000000017 Vs 09:53:50 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0008000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000001339 +- 0.000000017 Vs BL = 0.00334664 +- 0.00004174 Tm 09:53:50 Integrated Voltage Measurement... 09:54:07 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 09:54:07 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000667 Vs 09:54:24 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000505 V 09:54:24 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000683 Vs 09:54:41 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000289 V 09:54:41 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000741 Vs 09:54:58 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000505 V 09:54:58 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000773 Vs 09:55:15 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000361 V 09:55:15 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000718 Vs 09:55:32 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000578 V 09:55:32 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000667 Vs 09:55:49 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000433 V 09:55:49 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000736 Vs 09:56:05 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000650 V 09:56:06 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000709 Vs 09:56:22 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000505 V 09:56:22 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000667 Vs 09:56:39 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 09:56:39 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000689 Vs 09:56:56 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000722 V 09:56:56 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000689 Vs 09:57:13 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000794 V 09:57:13 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000749 Vs 09:57:30 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000433 V 09:57:30 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000692 Vs 09:57:47 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000505 V 09:57:47 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000660 Vs 09:57:47 Integrated Voltage Average and RMS of Measurements X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000703 +- 0.000000029 Vs 09:57:47 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0004000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000000703 +- 0.000000029 Vs BL = 0.00175716 +- 0.00007198 Tm 09:57:48 Integrated Voltage Measurement... 09:58:05 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000361 V 09:58:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = -0.000000004 Vs 09:58:22 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000505 V 09:58:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = 0.000000008 Vs 09:58:39 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 09:58:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000022 Vs 09:58:56 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000578 V 09:58:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000098 Vs 09:59:12 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 09:59:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = -0.000000012 Vs 09:59:29 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000505 V 09:59:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000084 Vs 09:59:46 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 09:59:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000015 Vs 10:00:03 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000217 V 10:00:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000006 Vs 10:00:20 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000144 V 10:00:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000023 Vs 10:00:37 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000505 V 10:00:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000069 Vs 10:00:54 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000072 V 10:00:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000054 Vs 10:01:11 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000505 V 10:01:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000047 Vs 10:01:28 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000217 V 10:01:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000089 Vs 10:01:45 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000433 V 10:01:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000072 Vs 10:01:45 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000040 +- 0.000000027 Vs 10:01:45 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000000040 +- 0.000000027 Vs BL = 0.00009921 +- 0.00006832 Tm 10:01:45 Integrated Voltage Measurement... 10:02:02 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 10:02:03 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000654 Vs 10:02:19 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000505 V 10:02:20 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000612 Vs 10:02:36 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000361 V 10:02:37 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000570 Vs 10:02:53 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000217 V 10:02:53 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000575 Vs 10:03:10 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 10:03:10 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000560 Vs 10:03:27 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000578 V 10:03:27 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000604 Vs 10:03:44 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000361 V 10:03:44 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000606 Vs 10:04:01 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000361 V 10:04:01 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000519 Vs 10:04:18 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000144 V 10:04:18 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000557 Vs 10:04:35 Voltage Offset Correction: v_off_ini = 0.000000144 V, v_off_fin = 0.000000433 V 10:04:35 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000615 Vs 10:04:52 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000144 V 10:04:52 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000572 Vs 10:05:09 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000289 V 10:05:09 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000595 Vs 10:05:26 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000361 V 10:05:26 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000593 Vs 10:05:43 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 10:05:43 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000561 Vs 10:05:43 Integrated Voltage Average and RMS of Measurements X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000585 +- 0.000000021 Vs 10:05:43 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0004000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000000585 +- 0.000000021 Vs BL = -0.00146285 +- 0.00005201 Tm 10:05:43 Integrated Voltage Measurement... 10:06:00 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000578 V 10:06:00 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001238 Vs 10:06:17 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000505 V 10:06:17 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001203 Vs 10:06:34 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000505 V 10:06:34 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001195 Vs 10:06:51 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000794 V 10:06:51 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001173 Vs 10:07:08 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000650 V 10:07:08 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001224 Vs 10:07:25 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000505 V 10:07:25 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001220 Vs 10:07:42 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000289 V 10:07:42 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001191 Vs 10:07:59 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000505 V 10:07:59 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001212 Vs 10:08:16 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000505 V 10:08:16 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001170 Vs 10:08:33 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000722 V 10:08:33 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001192 Vs 10:08:50 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000505 V 10:08:50 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001221 Vs 10:09:07 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000505 V 10:09:07 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001230 Vs 10:09:24 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000505 V 10:09:24 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001207 Vs 10:09:41 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000578 V 10:09:41 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001162 Vs 10:09:41 Integrated Voltage Average and RMS of Measurements X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001203 +- 0.000000018 Vs 10:09:41 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0008000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000001203 +- 0.000000018 Vs BL = -0.00300641 +- 0.00004597 Tm 10:09:41 Integrated Voltage Measurement... 10:09:58 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000650 V 10:09:58 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001925 Vs 10:10:15 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000361 V 10:10:15 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001835 Vs 10:10:32 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000361 V 10:10:32 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001796 Vs 10:10:49 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000650 V 10:10:49 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001825 Vs 10:11:06 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000361 V 10:11:06 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001869 Vs 10:11:23 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000578 V 10:11:23 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001850 Vs 10:11:40 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000505 V 10:11:40 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001853 Vs 10:11:57 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000217 V 10:11:57 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001881 Vs 10:12:14 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000505 V 10:12:14 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001818 Vs 10:12:31 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000650 V 10:12:31 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001821 Vs 10:12:48 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000361 V 10:12:48 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001846 Vs 10:13:05 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000578 V 10:13:05 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001880 Vs 10:13:22 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000505 V 10:13:22 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001844 Vs 10:13:39 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000578 V 10:13:39 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001846 Vs 10:13:39 Integrated Voltage Average and RMS of Measurements X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001849 +- 0.000000024 Vs 10:13:39 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0012000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000001849 +- 0.000000024 Vs BL = -0.00462309 +- 0.00005963 Tm 10:13:47 Integrated Voltage Measurement... 10:14:05 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 10:14:05 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001972 Vs 10:14:22 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000578 V 10:14:22 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001974 Vs 10:14:38 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 10:14:39 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002031 Vs 10:14:55 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000722 V 10:14:56 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002069 Vs 10:15:12 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 10:15:13 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001963 Vs 10:15:29 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 10:15:29 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002004 Vs 10:15:46 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000578 V 10:15:46 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002038 Vs 10:16:03 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000505 V 10:16:03 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002015 Vs 10:16:20 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000505 V 10:16:20 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002006 Vs 10:16:37 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000578 V 10:16:37 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000001963 Vs 10:16:54 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000433 V 10:16:54 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001986 Vs 10:17:11 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000794 V 10:17:11 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002047 Vs 10:17:28 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000722 V 10:17:28 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000001980 Vs 10:17:45 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000722 V 10:17:45 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0004000 m VT = -0.000002029 Vs 10:17:45 Integrated Voltage Average and RMS of Measurements X0 = -0.0012000 m, Delta X = 0.0004000 m VT = 0.000002006 +- 0.000000025 Vs 10:17:45 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0012000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000002006 +- 0.000000025 Vs BL = 0.00501383 +- 0.00006356 Tm 10:17:45 Integrated Voltage Measurement... 10:18:02 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000505 V 10:18:03 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001264 Vs 10:18:19 Voltage Offset Correction: v_off_ini = 0.000000866 V, v_off_fin = 0.000000794 V 10:18:19 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001368 Vs 10:18:36 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000361 V 10:18:36 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001335 Vs 10:18:53 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 10:18:53 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001347 Vs 10:19:10 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000578 V 10:19:10 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001291 Vs 10:19:27 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000794 V 10:19:27 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001410 Vs 10:19:44 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000361 V 10:19:45 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001354 Vs 10:20:02 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000650 V 10:20:02 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001402 Vs 10:20:19 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000361 V 10:20:19 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001333 Vs 10:20:35 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000289 V 10:20:36 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001350 Vs 10:20:52 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 10:20:52 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001361 Vs 10:21:09 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000361 V 10:21:09 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001345 Vs 10:21:26 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000217 V 10:21:26 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001351 Vs 10:21:43 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 10:21:43 Integrated Voltage Measurement X0 = -0.0008000 m, Delta X = -0.0004000 m VT = -0.000001372 Vs 10:21:43 Integrated Voltage Average and RMS of Measurements X0 = -0.0008000 m, Delta X = 0.0004000 m VT = 0.000001349 +- 0.000000018 Vs 10:21:43 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0008000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000001349 +- 0.000000018 Vs BL = 0.00337192 +- 0.00004455 Tm 10:21:44 Integrated Voltage Measurement... 10:22:01 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000578 V 10:22:01 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000657 Vs 10:22:18 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 10:22:18 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000755 Vs 10:22:35 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 10:22:35 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000715 Vs 10:22:51 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000433 V 10:22:52 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000730 Vs 10:23:08 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000505 V 10:23:09 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000675 Vs 10:23:25 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 10:23:25 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000681 Vs 10:23:42 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000578 V 10:23:42 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000654 Vs 10:23:59 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000650 V 10:23:59 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000712 Vs 10:24:16 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000433 V 10:24:16 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000692 Vs 10:24:33 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 10:24:33 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000707 Vs 10:24:50 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000361 V 10:24:50 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000715 Vs 10:25:07 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000650 V 10:25:07 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000737 Vs 10:25:24 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 10:25:24 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000736 Vs 10:25:41 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000505 V 10:25:41 Integrated Voltage Measurement X0 = -0.0004000 m, Delta X = -0.0004000 m VT = -0.000000683 Vs 10:25:41 Integrated Voltage Average and RMS of Measurements X0 = -0.0004000 m, Delta X = 0.0004000 m VT = 0.000000703 +- 0.000000017 Vs 10:25:41 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0004000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000000703 +- 0.000000017 Vs BL = 0.00175860 +- 0.00004205 Tm 10:25:41 Integrated Voltage Measurement... 10:25:58 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000722 V 10:25:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = -0.000000014 Vs 10:26:15 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000722 V 10:26:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000067 Vs 10:26:32 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000578 V 10:26:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000015 Vs 10:26:49 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000505 V 10:26:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000061 Vs 10:27:06 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000361 V 10:27:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000034 Vs 10:27:23 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 10:27:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000043 Vs 10:27:40 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000217 V 10:27:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000080 Vs 10:27:57 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000505 V 10:27:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000046 Vs 10:28:14 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000505 V 10:28:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000009 Vs 10:28:31 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000650 V 10:28:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000110 Vs 10:28:48 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000578 V 10:28:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000004 Vs 10:29:05 Voltage Offset Correction: v_off_ini = 0.000000722 V, v_off_fin = 0.000000578 V 10:29:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000090 Vs 10:29:22 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000361 V 10:29:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000059 Vs 10:29:39 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000505 V 10:29:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0004000 m VT = -0.000000076 Vs 10:29:39 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0004000 m VT = 0.000000049 +- 0.000000014 Vs 10:29:39 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0004000 m, Nturns = 1.0 VT = 0.000000049 +- 0.000000014 Vs BL = 0.00012162 +- 0.00003540 Tm 10:29:39 Integrated Voltage Measurement... 10:29:56 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 10:29:56 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000530 Vs 10:30:13 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000578 V 10:30:13 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000561 Vs 10:30:30 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000578 V 10:30:30 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000600 Vs 10:30:47 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000722 V 10:30:47 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000524 Vs 10:31:04 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 10:31:04 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000578 Vs 10:31:21 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000578 V 10:31:21 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000543 Vs 10:31:38 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 10:31:38 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000626 Vs 10:31:55 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000578 V 10:31:55 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000552 Vs 10:32:12 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 10:32:12 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000562 Vs 10:32:29 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 10:32:29 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000540 Vs 10:32:46 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 10:32:46 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000604 Vs 10:33:03 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000794 V 10:33:03 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000548 Vs 10:33:20 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000433 V 10:33:20 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000617 Vs 10:33:37 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000722 V 10:33:37 Integrated Voltage Measurement X0 = 0.0004000 m, Delta X = -0.0004000 m VT = 0.000000540 Vs 10:33:37 Integrated Voltage Average and RMS of Measurements X0 = 0.0004000 m, Delta X = 0.0004000 m VT = -0.000000566 +- 0.000000015 Vs 10:33:37 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0004000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000000566 +- 0.000000015 Vs BL = -0.00141521 +- 0.00003626 Tm 10:33:37 Integrated Voltage Measurement... 10:33:54 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000289 V 10:33:54 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001189 Vs 10:34:11 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000505 V 10:34:11 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001242 Vs 10:34:28 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000505 V 10:34:28 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001180 Vs 10:34:45 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 10:34:45 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001213 Vs 10:35:02 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000361 V 10:35:02 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001177 Vs 10:35:19 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000578 V 10:35:19 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001195 Vs 10:35:36 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000144 V 10:35:36 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001121 Vs 10:35:53 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000361 V 10:35:53 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001218 Vs 10:36:10 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000361 V 10:36:10 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001224 Vs 10:36:27 Voltage Offset Correction: v_off_ini = 0.000000072 V, v_off_fin = 0.000000433 V 10:36:27 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001222 Vs 10:36:44 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000217 V 10:36:44 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001162 Vs 10:37:01 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000650 V 10:37:01 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001197 Vs 10:37:18 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000217 V 10:37:18 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001165 Vs 10:37:35 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000361 V 10:37:35 Integrated Voltage Measurement X0 = 0.0008000 m, Delta X = -0.0004000 m VT = 0.000001243 Vs 10:37:35 Integrated Voltage Average and RMS of Measurements X0 = 0.0008000 m, Delta X = 0.0004000 m VT = -0.000001196 +- 0.000000018 Vs 10:37:35 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0008000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000001196 +- 0.000000018 Vs BL = -0.00299077 +- 0.00004512 Tm 10:37:35 Integrated Voltage Measurement... 10:37:52 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 10:37:52 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001894 Vs 10:38:09 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000433 V 10:38:09 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001842 Vs 10:38:26 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 10:38:26 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001884 Vs 10:38:43 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000000578 V 10:38:43 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001863 Vs 10:39:00 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 10:39:00 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001890 Vs 10:39:17 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000722 V 10:39:17 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001861 Vs 10:39:34 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000505 V 10:39:34 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001880 Vs 10:39:51 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000866 V 10:39:51 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001792 Vs 10:40:08 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000578 V 10:40:08 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001889 Vs 10:40:25 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 10:40:25 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001801 Vs 10:40:42 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000505 V 10:40:42 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001892 Vs 10:40:59 Voltage Offset Correction: v_off_ini = 0.000000505 V, v_off_fin = 0.000000578 V 10:40:59 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001879 Vs 10:41:16 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000361 V 10:41:16 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001866 Vs 10:41:33 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000000361 V 10:41:33 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0004000 m VT = 0.000001887 Vs 10:41:33 Integrated Voltage Average and RMS of Measurements X0 = 0.0012000 m, Delta X = 0.0004000 m VT = -0.000001866 +- 0.000000017 Vs 10:41:33 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0012000 m, dx = 0.0004000 m, Nturns = 1.0 VT = -0.000001866 +- 0.000000017 Vs BL = -0.00466423 +- 0.00004218 Tm 10:41:53 Name = None, is zeroed