SLAC Magnetic Measurements Date: 09-18-2008 Time: 10:44:34 Project: E163 Magnet Type: quad Magnet Name: PMQ3 Serial Number: 3 Run Number: 9 Measurement Device: 1 wire Operator: sda Comment: Integrated strength. wire back on center, moved wire off motor Test Currents (A): 0.0 10:44:43 Name = None, is zeroed 10:44:43 Magnetic Field Measurement Measuring the magnet strength... 10:44:43 Integrated Voltage Measurement... 10:44:52 Voltage Offset Correction: v_off_ini = -0.000001405 V, v_off_fin = -0.000001012 V 10:44:52 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0006000 m VT = -0.000003265 Vs 10:45:01 Voltage Offset Correction: v_off_ini = -0.000001250 V, v_off_fin = -0.000001212 V 10:45:01 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0006000 m VT = 0.000003063 Vs 10:45:09 Voltage Offset Correction: v_off_ini = -0.000001183 V, v_off_fin = -0.000001322 V 10:45:09 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0006000 m VT = -0.000003077 Vs 10:45:18 Voltage Offset Correction: v_off_ini = -0.000001307 V, v_off_fin = -0.000001183 V 10:45:18 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0006000 m VT = 0.000003121 Vs 10:45:27 Voltage Offset Correction: v_off_ini = -0.000001334 V, v_off_fin = -0.000001317 V 10:45:27 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0006000 m VT = -0.000002980 Vs 10:45:35 Voltage Offset Correction: v_off_ini = -0.000001232 V, v_off_fin = -0.000001205 V 10:45:35 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0006000 m VT = 0.000003138 Vs 10:45:44 Voltage Offset Correction: v_off_ini = -0.000001338 V, v_off_fin = -0.000001322 V 10:45:44 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0006000 m VT = -0.000003198 Vs 10:45:53 Voltage Offset Correction: v_off_ini = -0.000001224 V, v_off_fin = -0.000001301 V 10:45:53 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0006000 m VT = 0.000003086 Vs 10:46:01 Voltage Offset Correction: v_off_ini = -0.000000978 V, v_off_fin = -0.000000975 V 10:46:01 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0006000 m VT = -0.000003189 Vs 10:46:10 Voltage Offset Correction: v_off_ini = -0.000001160 V, v_off_fin = -0.000001195 V 10:46:10 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0006000 m VT = 0.000003065 Vs 10:46:19 Voltage Offset Correction: v_off_ini = -0.000001436 V, v_off_fin = -0.000001319 V 10:46:19 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0006000 m VT = -0.000003141 Vs 10:46:27 Voltage Offset Correction: v_off_ini = -0.000001257 V, v_off_fin = -0.000001220 V 10:46:27 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0006000 m VT = 0.000003154 Vs 10:46:36 Voltage Offset Correction: v_off_ini = -0.000000977 V, v_off_fin = -0.000000829 V 10:46:36 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0006000 m VT = -0.000003075 Vs 10:46:45 Voltage Offset Correction: v_off_ini = -0.000001206 V, v_off_fin = -0.000001322 V 10:46:45 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0006000 m VT = 0.000003096 Vs 10:46:53 Voltage Offset Correction: v_off_ini = -0.000001027 V, v_off_fin = -0.000001177 V 10:46:53 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0006000 m VT = -0.000003305 Vs 10:47:02 Voltage Offset Correction: v_off_ini = -0.000001204 V, v_off_fin = -0.000001120 V 10:47:02 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0006000 m VT = 0.000003117 Vs 10:47:10 Voltage Offset Correction: v_off_ini = -0.000001251 V, v_off_fin = -0.000001434 V 10:47:10 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0006000 m VT = -0.000003104 Vs 10:47:19 Voltage Offset Correction: v_off_ini = -0.000001231 V, v_off_fin = -0.000001085 V 10:47:19 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0006000 m VT = 0.000003172 Vs 10:47:28 Voltage Offset Correction: v_off_ini = -0.000001246 V, v_off_fin = -0.000001334 V 10:47:28 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0006000 m VT = -0.000003196 Vs 10:47:36 Voltage Offset Correction: v_off_ini = -0.000001291 V, v_off_fin = -0.000001188 V 10:47:36 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0006000 m VT = 0.000003186 Vs 10:47:36 Integrated Voltage Average and RMS of Measurements X0 = -0.0012000 m, Delta X = 0.0006000 m VT = -0.000003136 +- 0.000000044 Vs 10:47:36 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0012000 m, dx = 0.0006000 m, Nturns = 1.0 VT = -0.000003136 +- 0.000000044 Vs BL = -0.00522731 +- 0.00007359 Tm 10:47:36 Integrated Voltage Measurement... 10:47:45 Voltage Offset Correction: v_off_ini = -0.000001338 V, v_off_fin = -0.000001363 V 10:47:45 Integrated Voltage Measurement X0 = -0.0006000 m, Delta X = 0.0006000 m VT = -0.000001400 Vs 10:47:54 Voltage Offset Correction: v_off_ini = -0.000001311 V, v_off_fin = -0.000001283 V 10:47:54 Integrated Voltage Measurement X0 = -0.0006000 m, Delta X = -0.0006000 m VT = 0.000001458 Vs 10:48:02 Voltage Offset Correction: v_off_ini = -0.000001258 V, v_off_fin = -0.000001232 V 10:48:02 Integrated Voltage Measurement X0 = -0.0006000 m, Delta X = 0.0006000 m VT = -0.000001447 Vs 10:48:11 Voltage Offset Correction: v_off_ini = -0.000001049 V, v_off_fin = -0.000001101 V 10:48:11 Integrated Voltage Measurement X0 = -0.0006000 m, Delta X = -0.0006000 m VT = 0.000001375 Vs 10:48:20 Voltage Offset Correction: v_off_ini = -0.000001124 V, v_off_fin = -0.000001132 V 10:48:20 Integrated Voltage Measurement X0 = -0.0006000 m, Delta X = 0.0006000 m VT = -0.000001396 Vs 10:48:29 Voltage Offset Correction: v_off_ini = -0.000001216 V, v_off_fin = -0.000001153 V 10:48:29 Integrated Voltage Measurement X0 = -0.0006000 m, Delta X = -0.0006000 m VT = 0.000001453 Vs 10:48:37 Voltage Offset Correction: v_off_ini = -0.000001234 V, v_off_fin = -0.000001193 V 10:48:37 Integrated Voltage Measurement X0 = -0.0006000 m, Delta X = 0.0006000 m VT = -0.000001459 Vs 10:48:46 Voltage Offset Correction: v_off_ini = -0.000001257 V, v_off_fin = -0.000001089 V 10:48:46 Integrated Voltage Measurement X0 = -0.0006000 m, Delta X = -0.0006000 m VT = 0.000001527 Vs 10:48:55 Voltage Offset Correction: v_off_ini = -0.000001272 V, v_off_fin = -0.000001202 V 10:48:55 Integrated Voltage Measurement X0 = -0.0006000 m, Delta X = 0.0006000 m VT = -0.000001527 Vs 10:49:03 Voltage Offset Correction: v_off_ini = -0.000001284 V, v_off_fin = -0.000001274 V 10:49:03 Integrated Voltage Measurement X0 = -0.0006000 m, Delta X = -0.0006000 m VT = 0.000001427 Vs 10:49:12 Voltage Offset Correction: v_off_ini = -0.000001041 V, v_off_fin = -0.000001010 V 10:49:12 Integrated Voltage Measurement X0 = -0.0006000 m, Delta X = 0.0006000 m VT = -0.000001444 Vs 10:49:21 Voltage Offset Correction: v_off_ini = -0.000001296 V, v_off_fin = -0.000001296 V 10:49:21 Integrated Voltage Measurement X0 = -0.0006000 m, Delta X = -0.0006000 m VT = 0.000001422 Vs 10:49:29 Voltage Offset Correction: v_off_ini = -0.000001035 V, v_off_fin = -0.000001150 V 10:49:29 Integrated Voltage Measurement X0 = -0.0006000 m, Delta X = 0.0006000 m VT = -0.000001624 Vs 10:49:38 Voltage Offset Correction: v_off_ini = -0.000001183 V, v_off_fin = -0.000001172 V 10:49:38 Integrated Voltage Measurement X0 = -0.0006000 m, Delta X = -0.0006000 m VT = 0.000001441 Vs 10:49:47 Voltage Offset Correction: v_off_ini = -0.000001266 V, v_off_fin = -0.000001558 V 10:49:47 Integrated Voltage Measurement X0 = -0.0006000 m, Delta X = 0.0006000 m VT = -0.000001650 Vs 10:49:55 Voltage Offset Correction: v_off_ini = -0.000001219 V, v_off_fin = -0.000001139 V 10:49:55 Integrated Voltage Measurement X0 = -0.0006000 m, Delta X = -0.0006000 m VT = 0.000001497 Vs 10:50:04 Voltage Offset Correction: v_off_ini = -0.000001166 V, v_off_fin = -0.000001294 V 10:50:04 Integrated Voltage Measurement X0 = -0.0006000 m, Delta X = 0.0006000 m VT = -0.000001443 Vs 10:50:13 Voltage Offset Correction: v_off_ini = -0.000001079 V, v_off_fin = -0.000000803 V 10:50:13 Integrated Voltage Measurement X0 = -0.0006000 m, Delta X = -0.0006000 m VT = 0.000001643 Vs 10:50:21 Voltage Offset Correction: v_off_ini = -0.000001124 V, v_off_fin = -0.000000965 V 10:50:21 Integrated Voltage Measurement X0 = -0.0006000 m, Delta X = 0.0006000 m VT = -0.000001530 Vs 10:50:30 Voltage Offset Correction: v_off_ini = -0.000001257 V, v_off_fin = -0.000001229 V 10:50:30 Integrated Voltage Measurement X0 = -0.0006000 m, Delta X = -0.0006000 m VT = 0.000001599 Vs 10:50:30 Integrated Voltage Average and RMS of Measurements X0 = -0.0006000 m, Delta X = 0.0006000 m VT = -0.000001488 +- 0.000000059 Vs 10:50:30 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0006000 m, dx = 0.0006000 m, Nturns = 1.0 VT = -0.000001488 +- 0.000000059 Vs BL = -0.00248007 +- 0.00009837 Tm 10:50:30 Integrated Voltage Measurement... 10:50:39 Voltage Offset Correction: v_off_ini = -0.000000955 V, v_off_fin = -0.000000894 V 10:50:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0006000 m VT = 0.000000315 Vs 10:50:47 Voltage Offset Correction: v_off_ini = -0.000001209 V, v_off_fin = -0.000001224 V 10:50:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0006000 m VT = -0.000000187 Vs 10:50:56 Voltage Offset Correction: v_off_ini = -0.000001033 V, v_off_fin = -0.000001063 V 10:50:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0006000 m VT = 0.000000179 Vs 10:51:05 Voltage Offset Correction: v_off_ini = -0.000001111 V, v_off_fin = -0.000001125 V 10:51:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0006000 m VT = -0.000000253 Vs 10:51:13 Voltage Offset Correction: v_off_ini = -0.000001153 V, v_off_fin = -0.000001329 V 10:51:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0006000 m VT = 0.000000300 Vs 10:51:22 Voltage Offset Correction: v_off_ini = -0.000001043 V, v_off_fin = -0.000000790 V 10:51:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0006000 m VT = -0.000000183 Vs 10:51:31 Voltage Offset Correction: v_off_ini = -0.000001168 V, v_off_fin = -0.000001377 V 10:51:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0006000 m VT = 0.000000238 Vs 10:51:39 Voltage Offset Correction: v_off_ini = -0.000001175 V, v_off_fin = -0.000001224 V 10:51:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0006000 m VT = -0.000000196 Vs 10:51:48 Voltage Offset Correction: v_off_ini = -0.000001208 V, v_off_fin = -0.000001324 V 10:51:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0006000 m VT = 0.000000149 Vs 10:51:57 Voltage Offset Correction: v_off_ini = -0.000001373 V, v_off_fin = -0.000001476 V 10:51:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0006000 m VT = -0.000000262 Vs 10:52:05 Voltage Offset Correction: v_off_ini = -0.000001087 V, v_off_fin = -0.000001082 V 10:52:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0006000 m VT = 0.000000245 Vs 10:52:14 Voltage Offset Correction: v_off_ini = -0.000001064 V, v_off_fin = -0.000000676 V 10:52:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0006000 m VT = -0.000000094 Vs 10:52:22 Voltage Offset Correction: v_off_ini = -0.000001121 V, v_off_fin = -0.000001101 V 10:52:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0006000 m VT = 0.000000104 Vs 10:52:31 Voltage Offset Correction: v_off_ini = -0.000001035 V, v_off_fin = -0.000000926 V 10:52:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0006000 m VT = -0.000000227 Vs 10:52:40 Voltage Offset Correction: v_off_ini = -0.000001318 V, v_off_fin = -0.000001134 V 10:52:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0006000 m VT = 0.000000148 Vs 10:52:49 Voltage Offset Correction: v_off_ini = -0.000000911 V, v_off_fin = -0.000000732 V 10:52:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0006000 m VT = 0.000000064 Vs 10:52:57 Voltage Offset Correction: v_off_ini = -0.000001045 V, v_off_fin = -0.000000975 V 10:52:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0006000 m VT = 0.000000218 Vs 10:53:06 Voltage Offset Correction: v_off_ini = -0.000001267 V, v_off_fin = -0.000001271 V 10:53:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0006000 m VT = -0.000000187 Vs 10:53:15 Voltage Offset Correction: v_off_ini = -0.000000985 V, v_off_fin = -0.000000956 V 10:53:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0006000 m VT = 0.000000263 Vs 10:53:23 Voltage Offset Correction: v_off_ini = -0.000001343 V, v_off_fin = -0.000000930 V 10:53:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0006000 m VT = -0.000000200 Vs 10:53:23 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0006000 m VT = 0.000000194 +- 0.000000057 Vs 10:53:23 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0006000 m, Nturns = 1.0 VT = 0.000000194 +- 0.000000057 Vs BL = 0.00032380 +- 0.00009525 Tm 10:53:23 Integrated Voltage Measurement... 10:53:32 Voltage Offset Correction: v_off_ini = -0.000001067 V, v_off_fin = -0.000000873 V 10:53:32 Integrated Voltage Measurement X0 = 0.0006000 m, Delta X = 0.0006000 m VT = 0.000001959 Vs 10:53:41 Voltage Offset Correction: v_off_ini = -0.000001145 V, v_off_fin = -0.000001112 V 10:53:41 Integrated Voltage Measurement X0 = 0.0006000 m, Delta X = -0.0006000 m VT = -0.000001973 Vs 10:53:49 Voltage Offset Correction: v_off_ini = -0.000001052 V, v_off_fin = -0.000001231 V 10:53:49 Integrated Voltage Measurement X0 = 0.0006000 m, Delta X = 0.0006000 m VT = 0.000001741 Vs 10:53:58 Voltage Offset Correction: v_off_ini = -0.000001014 V, v_off_fin = -0.000000986 V 10:53:58 Integrated Voltage Measurement X0 = 0.0006000 m, Delta X = -0.0006000 m VT = -0.000001977 Vs 10:54:07 Voltage Offset Correction: v_off_ini = -0.000001104 V, v_off_fin = -0.000001113 V 10:54:07 Integrated Voltage Measurement X0 = 0.0006000 m, Delta X = 0.0006000 m VT = 0.000002004 Vs 10:54:15 Voltage Offset Correction: v_off_ini = -0.000001068 V, v_off_fin = -0.000001175 V 10:54:15 Integrated Voltage Measurement X0 = 0.0006000 m, Delta X = -0.0006000 m VT = -0.000001853 Vs 10:54:24 Voltage Offset Correction: v_off_ini = -0.000001353 V, v_off_fin = -0.000001708 V 10:54:24 Integrated Voltage Measurement X0 = 0.0006000 m, Delta X = 0.0006000 m VT = 0.000001961 Vs 10:54:33 Voltage Offset Correction: v_off_ini = -0.000001287 V, v_off_fin = -0.000001264 V 10:54:33 Integrated Voltage Measurement X0 = 0.0006000 m, Delta X = -0.0006000 m VT = -0.000001965 Vs 10:54:41 Voltage Offset Correction: v_off_ini = -0.000001333 V, v_off_fin = -0.000001323 V 10:54:41 Integrated Voltage Measurement X0 = 0.0006000 m, Delta X = 0.0006000 m VT = 0.000001921 Vs 10:54:50 Voltage Offset Correction: v_off_ini = -0.000000959 V, v_off_fin = -0.000000990 V 10:54:50 Integrated Voltage Measurement X0 = 0.0006000 m, Delta X = -0.0006000 m VT = -0.000001919 Vs 10:54:59 Voltage Offset Correction: v_off_ini = -0.000001091 V, v_off_fin = -0.000001202 V 10:54:59 Integrated Voltage Measurement X0 = 0.0006000 m, Delta X = 0.0006000 m VT = 0.000001752 Vs 10:55:07 Voltage Offset Correction: v_off_ini = -0.000001158 V, v_off_fin = -0.000001139 V 10:55:07 Integrated Voltage Measurement X0 = 0.0006000 m, Delta X = -0.0006000 m VT = -0.000001847 Vs 10:55:16 Voltage Offset Correction: v_off_ini = -0.000001106 V, v_off_fin = -0.000000943 V 10:55:16 Integrated Voltage Measurement X0 = 0.0006000 m, Delta X = 0.0006000 m VT = 0.000001872 Vs 10:55:24 Voltage Offset Correction: v_off_ini = -0.000001045 V, v_off_fin = -0.000001137 V 10:55:24 Integrated Voltage Measurement X0 = 0.0006000 m, Delta X = -0.0006000 m VT = -0.000001919 Vs 10:55:33 Voltage Offset Correction: v_off_ini = -0.000001105 V, v_off_fin = -0.000001146 V 10:55:33 Integrated Voltage Measurement X0 = 0.0006000 m, Delta X = 0.0006000 m VT = 0.000001891 Vs 10:55:42 Voltage Offset Correction: v_off_ini = -0.000001013 V, v_off_fin = -0.000001032 V 10:55:42 Integrated Voltage Measurement X0 = 0.0006000 m, Delta X = -0.0006000 m VT = -0.000001787 Vs 10:55:50 Voltage Offset Correction: v_off_ini = -0.000001036 V, v_off_fin = -0.000000973 V 10:55:50 Integrated Voltage Measurement X0 = 0.0006000 m, Delta X = 0.0006000 m VT = 0.000001849 Vs 10:55:59 Voltage Offset Correction: v_off_ini = -0.000001158 V, v_off_fin = -0.000001068 V 10:55:59 Integrated Voltage Measurement X0 = 0.0006000 m, Delta X = -0.0006000 m VT = -0.000001906 Vs 10:56:08 Voltage Offset Correction: v_off_ini = -0.000000950 V, v_off_fin = -0.000001006 V 10:56:08 Integrated Voltage Measurement X0 = 0.0006000 m, Delta X = 0.0006000 m VT = 0.000002014 Vs 10:56:16 Voltage Offset Correction: v_off_ini = -0.000001257 V, v_off_fin = -0.000001466 V 10:56:16 Integrated Voltage Measurement X0 = 0.0006000 m, Delta X = -0.0006000 m VT = -0.000002028 Vs 10:56:16 Integrated Voltage Average and RMS of Measurements X0 = 0.0006000 m, Delta X = 0.0006000 m VT = 0.000001907 +- 0.000000063 Vs 10:56:16 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0006000 m, dx = 0.0006000 m, Nturns = 1.0 VT = 0.000001907 +- 0.000000063 Vs BL = 0.00317800 +- 0.00010535 Tm 10:56:17 Integrated Voltage Measurement... 10:56:25 Voltage Offset Correction: v_off_ini = -0.000001317 V, v_off_fin = -0.000001388 V 10:56:25 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0006000 m VT = 0.000003611 Vs 10:56:34 Voltage Offset Correction: v_off_ini = -0.000001283 V, v_off_fin = -0.000001153 V 10:56:34 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0006000 m VT = -0.000003579 Vs 10:56:42 Voltage Offset Correction: v_off_ini = -0.000001071 V, v_off_fin = -0.000001074 V 10:56:42 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0006000 m VT = 0.000003495 Vs 10:56:51 Voltage Offset Correction: v_off_ini = -0.000000995 V, v_off_fin = -0.000001280 V 10:56:51 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0006000 m VT = -0.000003471 Vs 10:57:00 Voltage Offset Correction: v_off_ini = -0.000001054 V, v_off_fin = -0.000001319 V 10:57:00 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0006000 m VT = 0.000003458 Vs 10:57:08 Voltage Offset Correction: v_off_ini = -0.000001216 V, v_off_fin = -0.000000873 V 10:57:08 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0006000 m VT = -0.000003591 Vs 10:57:17 Voltage Offset Correction: v_off_ini = -0.000001148 V, v_off_fin = -0.000001262 V 10:57:17 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0006000 m VT = 0.000003773 Vs 10:57:26 Voltage Offset Correction: v_off_ini = -0.000001032 V, v_off_fin = -0.000001135 V 10:57:26 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0006000 m VT = -0.000003657 Vs 10:57:34 Voltage Offset Correction: v_off_ini = -0.000001053 V, v_off_fin = -0.000000849 V 10:57:34 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0006000 m VT = 0.000003673 Vs 10:57:43 Voltage Offset Correction: v_off_ini = -0.000000936 V, v_off_fin = -0.000001056 V 10:57:43 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0006000 m VT = -0.000003701 Vs 10:57:52 Voltage Offset Correction: v_off_ini = -0.000000923 V, v_off_fin = -0.000001093 V 10:57:52 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0006000 m VT = 0.000003542 Vs 10:58:00 Voltage Offset Correction: v_off_ini = -0.000001062 V, v_off_fin = -0.000001044 V 10:58:00 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0006000 m VT = -0.000003622 Vs 10:58:09 Voltage Offset Correction: v_off_ini = -0.000001142 V, v_off_fin = -0.000001083 V 10:58:09 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0006000 m VT = 0.000003706 Vs 10:58:18 Voltage Offset Correction: v_off_ini = -0.000001124 V, v_off_fin = -0.000001032 V 10:58:18 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0006000 m VT = -0.000003738 Vs 10:58:26 Voltage Offset Correction: v_off_ini = -0.000001349 V, v_off_fin = -0.000001263 V 10:58:26 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0006000 m VT = 0.000003659 Vs 10:58:35 Voltage Offset Correction: v_off_ini = -0.000001141 V, v_off_fin = -0.000001115 V 10:58:35 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0006000 m VT = -0.000003560 Vs 10:58:44 Voltage Offset Correction: v_off_ini = -0.000001186 V, v_off_fin = -0.000001182 V 10:58:44 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0006000 m VT = 0.000003503 Vs 10:58:52 Voltage Offset Correction: v_off_ini = -0.000001100 V, v_off_fin = -0.000001204 V 10:58:52 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0006000 m VT = -0.000003670 Vs 10:59:01 Voltage Offset Correction: v_off_ini = -0.000001083 V, v_off_fin = -0.000001213 V 10:59:01 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0006000 m VT = 0.000003539 Vs 10:59:10 Voltage Offset Correction: v_off_ini = -0.000001130 V, v_off_fin = -0.000001141 V 10:59:10 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0006000 m VT = -0.000003817 Vs 10:59:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0012000 m, Delta X = 0.0006000 m VT = 0.000003618 +- 0.000000077 Vs 10:59:10 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0012000 m, dx = 0.0006000 m, Nturns = 1.0 VT = 0.000003618 +- 0.000000077 Vs BL = 0.00603047 +- 0.00012755 Tm 10:59:12 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00036 0.00005 1 4.69561 0.05465 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- -0.0012000 -0.00523 0.00007 -0.00527 0.00004 -0.0006000 -0.00248 0.00010 -0.00245 -0.00003 0.0000000 0.00032 0.00010 0.00036 -0.00004 0.0006000 0.00318 0.00011 0.00318 -0.00000 0.0012000 0.00603 0.00013 0.00600 0.00003 10:59:12 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 5 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0012 -0.00523 0.00007 -0.0006 -0.00248 0.00010 0.0000 0.00032 0.00010 0.0006 0.00318 0.00011 0.0012 0.00603 0.00013 SL = 4.6956052 +- 0.0546470 Tm^2/m^n 10:59:12 Quadrupole Strength Calculation Check Slope = 4.695605 Tm/m, Inter = 0.000365 Tm, Sig_slope = 0.022003 Tm/m, Est_sig = 0.000042 Tm GL = 4.695605 +- 0.022003 T 10:59:12 Magnet Strength Measurement Harmonic Number = 2 SL = 4.6956052 +- 0.0546470 Tm^2/m^n 10:59:14 Name = None, is zeroed