SLAC Magnetic Measurements Date: 09-17-2008 Time: 14:46:01 Project: E163 Magnet Type: quad Magnet Name: PMQ3 Serial Number: 3 Run Number: 6 Measurement Device: 1 wire Operator: sda Comment: Integrated strength Test Currents (A): 0.0 0.0 14:46:10 Name = None, is zeroed 14:46:10 Magnetic Field Measurement Measuring the magnet strength... 14:46:10 Integrated Voltage Measurement... 14:46:18 Voltage Offset Correction: v_off_ini = -0.000001118 V, v_off_fin = -0.000001085 V 14:46:18 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0006000 m VT = -0.000003611 Vs 14:46:27 Voltage Offset Correction: v_off_ini = -0.000001234 V, v_off_fin = -0.000001339 V 14:46:27 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0006000 m VT = 0.000003559 Vs 14:46:36 Voltage Offset Correction: v_off_ini = -0.000001025 V, v_off_fin = -0.000000965 V 14:46:36 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0006000 m VT = -0.000003637 Vs 14:46:44 Voltage Offset Correction: v_off_ini = -0.000001232 V, v_off_fin = -0.000001085 V 14:46:44 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0006000 m VT = 0.000003341 Vs 14:46:53 Voltage Offset Correction: v_off_ini = -0.000001348 V, v_off_fin = -0.000001494 V 14:46:53 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0006000 m VT = -0.000003400 Vs 14:47:02 Voltage Offset Correction: v_off_ini = -0.000001073 V, v_off_fin = -0.000000990 V 14:47:02 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0006000 m VT = 0.000003250 Vs 14:47:10 Voltage Offset Correction: v_off_ini = -0.000000992 V, v_off_fin = -0.000001331 V 14:47:10 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0006000 m VT = -0.000003402 Vs 14:47:19 Voltage Offset Correction: v_off_ini = -0.000001222 V, v_off_fin = -0.000001137 V 14:47:19 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0006000 m VT = 0.000003459 Vs 14:47:28 Voltage Offset Correction: v_off_ini = -0.000000970 V, v_off_fin = -0.000000821 V 14:47:28 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0006000 m VT = -0.000003495 Vs 14:47:36 Voltage Offset Correction: v_off_ini = -0.000001198 V, v_off_fin = -0.000001624 V 14:47:36 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0006000 m VT = 0.000003730 Vs 14:47:45 Voltage Offset Correction: v_off_ini = -0.000000892 V, v_off_fin = -0.000001157 V 14:47:45 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0006000 m VT = -0.000003414 Vs 14:47:53 Voltage Offset Correction: v_off_ini = -0.000001226 V, v_off_fin = -0.000001269 V 14:47:53 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0006000 m VT = 0.000003403 Vs 14:48:02 Voltage Offset Correction: v_off_ini = -0.000001141 V, v_off_fin = -0.000001134 V 14:48:02 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0006000 m VT = -0.000003373 Vs 14:48:11 Voltage Offset Correction: v_off_ini = -0.000001001 V, v_off_fin = -0.000000768 V 14:48:11 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0006000 m VT = 0.000002922 Vs 14:48:19 Voltage Offset Correction: v_off_ini = -0.000001033 V, v_off_fin = -0.000001047 V 14:48:19 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = 0.0006000 m VT = -0.000003411 Vs 14:48:28 Voltage Offset Correction: v_off_ini = -0.000001145 V, v_off_fin = -0.000000787 V 14:48:28 Integrated Voltage Measurement X0 = -0.0012000 m, Delta X = -0.0006000 m VT = 0.000003253 Vs 14:48:28 Integrated Voltage Average and RMS of Measurements X0 = -0.0012000 m, Delta X = 0.0006000 m VT = -0.000003416 +- 0.000000142 Vs 14:48:28 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0012000 m, dx = 0.0006000 m, Nturns = 1.0 VT = -0.000003416 +- 0.000000142 Vs BL = -0.00569394 +- 0.00023592 Tm 14:48:28 Integrated Voltage Measurement... 14:48:37 Voltage Offset Correction: v_off_ini = -0.000001004 V, v_off_fin = -0.000000898 V 14:48:37 Integrated Voltage Measurement X0 = -0.0006000 m, Delta X = 0.0006000 m VT = -0.000001787 Vs 14:48:45 Voltage Offset Correction: v_off_ini = -0.000001272 V, v_off_fin = -0.000001267 V 14:48:45 Integrated Voltage Measurement X0 = -0.0006000 m, Delta X = -0.0006000 m VT = 0.000001818 Vs 14:48:54 Voltage Offset Correction: v_off_ini = -0.000001157 V, v_off_fin = -0.000001032 V 14:48:54 Integrated Voltage Measurement X0 = -0.0006000 m, Delta X = 0.0006000 m VT = -0.000001617 Vs 14:49:03 Voltage Offset Correction: v_off_ini = -0.000001132 V, v_off_fin = -0.000001390 V 14:49:03 Integrated Voltage Measurement X0 = -0.0006000 m, Delta X = -0.0006000 m VT = 0.000001610 Vs 14:49:11 Voltage Offset Correction: v_off_ini = -0.000000982 V, v_off_fin = -0.000000969 V 14:49:11 Integrated Voltage Measurement X0 = -0.0006000 m, Delta X = 0.0006000 m VT = -0.000001760 Vs 14:49:20 Voltage Offset Correction: v_off_ini = -0.000001092 V, v_off_fin = -0.000000947 V 14:49:20 Integrated Voltage Measurement X0 = -0.0006000 m, Delta X = -0.0006000 m VT = 0.000001635 Vs 14:49:29 Voltage Offset Correction: v_off_ini = -0.000000973 V, v_off_fin = -0.000000976 V 14:49:29 Integrated Voltage Measurement X0 = -0.0006000 m, Delta X = 0.0006000 m VT = -0.000001709 Vs 14:49:37 Voltage Offset Correction: v_off_ini = -0.000000917 V, v_off_fin = -0.000000924 V 14:49:37 Integrated Voltage Measurement X0 = -0.0006000 m, Delta X = -0.0006000 m VT = 0.000001564 Vs 14:49:46 Voltage Offset Correction: v_off_ini = -0.000000976 V, v_off_fin = -0.000000905 V 14:49:46 Integrated Voltage Measurement X0 = -0.0006000 m, Delta X = 0.0006000 m VT = -0.000001767 Vs 14:49:55 Voltage Offset Correction: v_off_ini = -0.000001183 V, v_off_fin = -0.000001095 V 14:49:55 Integrated Voltage Measurement X0 = -0.0006000 m, Delta X = -0.0006000 m VT = 0.000001737 Vs 14:50:04 Voltage Offset Correction: v_off_ini = -0.000001009 V, v_off_fin = -0.000000971 V 14:50:04 Integrated Voltage Measurement X0 = -0.0006000 m, Delta X = 0.0006000 m VT = -0.000001771 Vs 14:50:12 Voltage Offset Correction: v_off_ini = -0.000001278 V, v_off_fin = -0.000001347 V 14:50:12 Integrated Voltage Measurement X0 = -0.0006000 m, Delta X = -0.0006000 m VT = 0.000001551 Vs 14:50:21 Voltage Offset Correction: v_off_ini = -0.000001122 V, v_off_fin = -0.000001183 V 14:50:21 Integrated Voltage Measurement X0 = -0.0006000 m, Delta X = 0.0006000 m VT = -0.000001544 Vs 14:50:29 Voltage Offset Correction: v_off_ini = -0.000001225 V, v_off_fin = -0.000001279 V 14:50:29 Integrated Voltage Measurement X0 = -0.0006000 m, Delta X = -0.0006000 m VT = 0.000001694 Vs 14:50:38 Voltage Offset Correction: v_off_ini = -0.000001231 V, v_off_fin = -0.000001163 V 14:50:38 Integrated Voltage Measurement X0 = -0.0006000 m, Delta X = 0.0006000 m VT = -0.000001668 Vs 14:50:47 Voltage Offset Correction: v_off_ini = -0.000000984 V, v_off_fin = -0.000001328 V 14:50:47 Integrated Voltage Measurement X0 = -0.0006000 m, Delta X = -0.0006000 m VT = 0.000001607 Vs 14:50:47 Integrated Voltage Average and RMS of Measurements X0 = -0.0006000 m, Delta X = 0.0006000 m VT = -0.000001677 +- 0.000000064 Vs 14:50:47 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0006000 m, dx = 0.0006000 m, Nturns = 1.0 VT = -0.000001677 +- 0.000000064 Vs BL = -0.00279569 +- 0.00010681 Tm 14:50:47 Integrated Voltage Measurement... 14:50:55 Voltage Offset Correction: v_off_ini = -0.000001195 V, v_off_fin = -0.000001244 V 14:50:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0006000 m VT = 0.000000307 Vs 14:51:04 Voltage Offset Correction: v_off_ini = -0.000001123 V, v_off_fin = -0.000001282 V 14:51:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0006000 m VT = -0.000000036 Vs 14:51:13 Voltage Offset Correction: v_off_ini = -0.000001045 V, v_off_fin = -0.000001005 V 14:51:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0006000 m VT = 0.000000024 Vs 14:51:21 Voltage Offset Correction: v_off_ini = -0.000001041 V, v_off_fin = -0.000001184 V 14:51:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0006000 m VT = -0.000000120 Vs 14:51:30 Voltage Offset Correction: v_off_ini = -0.000001030 V, v_off_fin = -0.000000878 V 14:51:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0006000 m VT = 0.000000014 Vs 14:51:39 Voltage Offset Correction: v_off_ini = -0.000001057 V, v_off_fin = -0.000001105 V 14:51:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0006000 m VT = -0.000000152 Vs 14:51:47 Voltage Offset Correction: v_off_ini = -0.000001156 V, v_off_fin = -0.000001030 V 14:51:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0006000 m VT = -0.000000050 Vs 14:51:56 Voltage Offset Correction: v_off_ini = -0.000001053 V, v_off_fin = -0.000000813 V 14:51:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0006000 m VT = 0.000000087 Vs 14:52:05 Voltage Offset Correction: v_off_ini = -0.000001286 V, v_off_fin = -0.000001024 V 14:52:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0006000 m VT = 0.000000001 Vs 14:52:13 Voltage Offset Correction: v_off_ini = -0.000001259 V, v_off_fin = -0.000001172 V 14:52:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0006000 m VT = 0.000000012 Vs 14:52:22 Voltage Offset Correction: v_off_ini = -0.000001123 V, v_off_fin = -0.000001141 V 14:52:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0006000 m VT = 0.000000125 Vs 14:52:31 Voltage Offset Correction: v_off_ini = -0.000001055 V, v_off_fin = -0.000001114 V 14:52:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0006000 m VT = 0.000000114 Vs 14:52:39 Voltage Offset Correction: v_off_ini = -0.000001253 V, v_off_fin = -0.000001262 V 14:52:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0006000 m VT = 0.000000190 Vs 14:52:48 Voltage Offset Correction: v_off_ini = -0.000001092 V, v_off_fin = -0.000001133 V 14:52:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0006000 m VT = -0.000000058 Vs 14:52:57 Voltage Offset Correction: v_off_ini = -0.000001164 V, v_off_fin = -0.000001446 V 14:52:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0006000 m VT = 0.000000246 Vs 14:53:05 Voltage Offset Correction: v_off_ini = -0.000001119 V, v_off_fin = -0.000000975 V 14:53:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0006000 m VT = 0.000000016 Vs 14:53:05 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0006000 m VT = 0.000000062 +- 0.000000074 Vs 14:53:05 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0006000 m, Nturns = 1.0 VT = 0.000000062 +- 0.000000074 Vs BL = 0.00010375 +- 0.00012378 Tm 14:53:06 Integrated Voltage Measurement... 14:53:14 Voltage Offset Correction: v_off_ini = -0.000001025 V, v_off_fin = -0.000001157 V 14:53:14 Integrated Voltage Measurement X0 = 0.0006000 m, Delta X = 0.0006000 m VT = 0.000001745 Vs 14:53:23 Voltage Offset Correction: v_off_ini = -0.000001236 V, v_off_fin = -0.000001180 V 14:53:23 Integrated Voltage Measurement X0 = 0.0006000 m, Delta X = -0.0006000 m VT = -0.000001810 Vs 14:53:32 Voltage Offset Correction: v_off_ini = -0.000001045 V, v_off_fin = -0.000000972 V 14:53:32 Integrated Voltage Measurement X0 = 0.0006000 m, Delta X = 0.0006000 m VT = 0.000001842 Vs 14:53:40 Voltage Offset Correction: v_off_ini = -0.000000774 V, v_off_fin = -0.000000579 V 14:53:40 Integrated Voltage Measurement X0 = 0.0006000 m, Delta X = -0.0006000 m VT = -0.000001648 Vs 14:53:49 Voltage Offset Correction: v_off_ini = -0.000000969 V, v_off_fin = -0.000001306 V 14:53:49 Integrated Voltage Measurement X0 = 0.0006000 m, Delta X = 0.0006000 m VT = 0.000001436 Vs 14:53:58 Voltage Offset Correction: v_off_ini = -0.000001029 V, v_off_fin = -0.000001113 V 14:53:58 Integrated Voltage Measurement X0 = 0.0006000 m, Delta X = -0.0006000 m VT = -0.000001765 Vs 14:54:06 Voltage Offset Correction: v_off_ini = -0.000001129 V, v_off_fin = -0.000000998 V 14:54:06 Integrated Voltage Measurement X0 = 0.0006000 m, Delta X = 0.0006000 m VT = 0.000001583 Vs 14:54:15 Voltage Offset Correction: v_off_ini = -0.000001236 V, v_off_fin = -0.000001224 V 14:54:15 Integrated Voltage Measurement X0 = 0.0006000 m, Delta X = -0.0006000 m VT = -0.000001835 Vs 14:54:24 Voltage Offset Correction: v_off_ini = -0.000001010 V, v_off_fin = -0.000001024 V 14:54:24 Integrated Voltage Measurement X0 = 0.0006000 m, Delta X = 0.0006000 m VT = 0.000001809 Vs 14:54:32 Voltage Offset Correction: v_off_ini = -0.000001046 V, v_off_fin = -0.000000961 V 14:54:32 Integrated Voltage Measurement X0 = 0.0006000 m, Delta X = -0.0006000 m VT = -0.000001772 Vs 14:54:41 Voltage Offset Correction: v_off_ini = -0.000001037 V, v_off_fin = -0.000000951 V 14:54:41 Integrated Voltage Measurement X0 = 0.0006000 m, Delta X = 0.0006000 m VT = 0.000001633 Vs 14:54:50 Voltage Offset Correction: v_off_ini = -0.000000917 V, v_off_fin = -0.000000840 V 14:54:50 Integrated Voltage Measurement X0 = 0.0006000 m, Delta X = -0.0006000 m VT = -0.000001618 Vs 14:54:58 Voltage Offset Correction: v_off_ini = -0.000000944 V, v_off_fin = -0.000000392 V 14:54:58 Integrated Voltage Measurement X0 = 0.0006000 m, Delta X = 0.0006000 m VT = 0.000001994 Vs 14:55:07 Voltage Offset Correction: v_off_ini = -0.000000916 V, v_off_fin = -0.000001017 V 14:55:07 Integrated Voltage Measurement X0 = 0.0006000 m, Delta X = -0.0006000 m VT = -0.000001713 Vs 14:55:16 Voltage Offset Correction: v_off_ini = -0.000000953 V, v_off_fin = -0.000001416 V 14:55:16 Integrated Voltage Measurement X0 = 0.0006000 m, Delta X = 0.0006000 m VT = 0.000001775 Vs 14:55:24 Voltage Offset Correction: v_off_ini = -0.000000908 V, v_off_fin = -0.000000807 V 14:55:24 Integrated Voltage Measurement X0 = 0.0006000 m, Delta X = -0.0006000 m VT = -0.000001746 Vs 14:55:24 Integrated Voltage Average and RMS of Measurements X0 = 0.0006000 m, Delta X = 0.0006000 m VT = 0.000001733 +- 0.000000079 Vs 14:55:24 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0006000 m, dx = 0.0006000 m, Nturns = 1.0 VT = 0.000001733 +- 0.000000079 Vs BL = 0.00288799 +- 0.00013206 Tm 14:55:24 Integrated Voltage Measurement... 14:55:33 Voltage Offset Correction: v_off_ini = -0.000000830 V, v_off_fin = -0.000000849 V 14:55:33 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0006000 m VT = 0.000003604 Vs 14:55:42 Voltage Offset Correction: v_off_ini = -0.000000782 V, v_off_fin = -0.000000861 V 14:55:42 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0006000 m VT = -0.000003565 Vs 14:55:50 Voltage Offset Correction: v_off_ini = -0.000000930 V, v_off_fin = -0.000001091 V 14:55:50 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0006000 m VT = 0.000003450 Vs 14:55:59 Voltage Offset Correction: v_off_ini = -0.000001091 V, v_off_fin = -0.000001334 V 14:55:59 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0006000 m VT = -0.000003445 Vs 14:56:08 Voltage Offset Correction: v_off_ini = -0.000000907 V, v_off_fin = -0.000001394 V 14:56:08 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0006000 m VT = 0.000003702 Vs 14:56:16 Voltage Offset Correction: v_off_ini = -0.000001089 V, v_off_fin = -0.000001123 V 14:56:16 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0006000 m VT = -0.000003436 Vs 14:56:25 Voltage Offset Correction: v_off_ini = -0.000001162 V, v_off_fin = -0.000001208 V 14:56:25 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0006000 m VT = 0.000003657 Vs 14:56:34 Voltage Offset Correction: v_off_ini = -0.000000989 V, v_off_fin = -0.000001074 V 14:56:34 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0006000 m VT = -0.000003490 Vs 14:56:42 Voltage Offset Correction: v_off_ini = -0.000001051 V, v_off_fin = -0.000000918 V 14:56:42 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0006000 m VT = 0.000003263 Vs 14:56:51 Voltage Offset Correction: v_off_ini = -0.000001173 V, v_off_fin = -0.000001089 V 14:56:51 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0006000 m VT = -0.000003351 Vs 14:57:00 Voltage Offset Correction: v_off_ini = -0.000001087 V, v_off_fin = -0.000001226 V 14:57:00 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0006000 m VT = 0.000003486 Vs 14:57:08 Voltage Offset Correction: v_off_ini = -0.000001004 V, v_off_fin = -0.000000936 V 14:57:08 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0006000 m VT = -0.000003491 Vs 14:57:17 Voltage Offset Correction: v_off_ini = -0.000001163 V, v_off_fin = -0.000001477 V 14:57:17 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0006000 m VT = 0.000003418 Vs 14:57:26 Voltage Offset Correction: v_off_ini = -0.000000838 V, v_off_fin = -0.000000959 V 14:57:26 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0006000 m VT = -0.000003606 Vs 14:57:34 Voltage Offset Correction: v_off_ini = -0.000000997 V, v_off_fin = -0.000001121 V 14:57:34 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = 0.0006000 m VT = 0.000003501 Vs 14:57:43 Voltage Offset Correction: v_off_ini = -0.000001242 V, v_off_fin = -0.000001371 V 14:57:43 Integrated Voltage Measurement X0 = 0.0012000 m, Delta X = -0.0006000 m VT = -0.000003416 Vs 14:57:43 Integrated Voltage Average and RMS of Measurements X0 = 0.0012000 m, Delta X = 0.0006000 m VT = 0.000003493 +- 0.000000086 Vs 14:57:43 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0012000 m, dx = 0.0006000 m, Nturns = 1.0 VT = 0.000003493 +- 0.000000086 Vs BL = 0.00582107 +- 0.00014309 Tm 14:57:45 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00006 0.00007 1 4.78562 0.09623 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- -0.0012000 -0.00569 0.00024 -0.00568 -0.00002 -0.0006000 -0.00280 0.00011 -0.00281 0.00001 0.0000000 0.00010 0.00012 0.00006 0.00004 0.0006000 0.00289 0.00013 0.00294 -0.00005 0.0012000 0.00582 0.00014 0.00581 0.00001 14:57:45 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 5 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0012 -0.00569 0.00024 -0.0006 -0.00280 0.00011 0.0000 0.00010 0.00012 0.0006 0.00289 0.00013 0.0012 0.00582 0.00014 SL = 4.7856157 +- 0.0962319 Tm^2/m^n 14:57:45 Quadrupole Strength Calculation Check Slope = 4.785616 Tm/m, Inter = 0.000065 Tm, Sig_slope = 0.020174 Tm/m, Est_sig = 0.000038 Tm GL = 4.785616 +- 0.020174 T 14:57:45 Magnet Strength Measurement Harmonic Number = 2 SL = 4.7856157 +- 0.0962319 Tm^2/m^n 14:57:45 Magnetic Field Measurement Measuring the magnet strength... 14:57:45 Integrated Voltage Measurement...