SLAC Magnetic Measurements Date: 08-17-2015 Time: 19:10:43 Project: LCLS Magnet Type: Undulator Magnet Name: Delta Magnet Mode: LPHMF Magnet Kind: 1 Kratio: 0.80 Run Number: 2 Measurement Device: 1wire Operator: sda Comment: Bx 1st integral vs x, x = -1.2 to 1.2 mm in 0.4 mm steps. Bx 2nd Field Integral Distance the wire was moved = 0.000400 m Number of turns in the wire = 1 Number of measurements for averaging = 6 Main +/- sigma X Y Integral sigIntegral (A) (m) (m) (Tm^2) -------------+--------- ----------- ----------- ------------+------------ 0.0000 0.0000 0.001200 0.000000 -0.001337 0.000160 0.0000 0.0000 0.001200 0.000000 -0.001472 0.000116 0.0000 0.0000 0.001200 0.000000 -0.001446 0.000256 0.0000 0.0000 0.000800 0.000000 -0.001126 0.000052 0.0000 0.0000 0.000800 0.000000 -0.001063 0.000068 0.0000 0.0000 0.000800 0.000000 -0.001077 0.000111 0.0000 0.0000 0.000400 0.000000 -0.000531 0.000129 0.0000 0.0000 0.000400 0.000000 -0.000586 0.000132 0.0000 0.0000 0.000400 0.000000 -0.000493 0.000088 0.0000 0.0000 0.000000 0.000000 -0.000070 0.000105 0.0000 0.0000 0.000000 0.000000 -0.000054 0.000108 0.0000 0.0000 0.000000 0.000000 -0.000115 0.000098 0.0000 0.0000 -0.000400 0.000000 0.000336 0.000080 0.0000 0.0000 -0.000400 0.000000 0.000415 0.000087 0.0000 0.0000 -0.000400 0.000000 0.000338 0.000170 0.0000 0.0000 -0.000800 0.000000 0.000744 0.000060 0.0000 0.0000 -0.000800 0.000000 0.000768 0.000099 0.0000 0.0000 -0.000800 0.000000 0.000703 0.000090 0.0000 0.0000 -0.001200 0.000000 0.001171 0.000138 0.0000 0.0000 -0.001200 0.000000 0.001053 0.000113 0.0000 0.0000 -0.001200 0.000000 0.000897 0.000049