SLAC Magnetic Measurements Date: 08-25-2009 Time: 09:16:36 Project: Calib Magnet Type: quad Magnet Name: 000709 Serial Number: Run Number: 1 Measurement Device: Short_Coil Operator: sda Comment: Calib PMQ coil (rad = 0.001969) using bucking factor becasue inner coil not on rotation axis. Dipole zeroed, Imag = 4.29814 Test Currents (A): 0.0 09:18:35 Vcoil, device being used, type = SR850 09:18:35 Stage Zeroed 09:18:35 MoveZ Devices: Move Device = NONE, Read Device = NONE 09:18:35 Move Stage, position = 0.000000 09:18:36 Stage Position Measurement, pos = 0.0000000 m 09:18:56 Coil Rotation Frequency Measurement freq = 29.994000 Hz 09:37:24 Coil Voltage Measurement n v_amp v_ph (V0p) (deg) --- ---------- ---------- 1 0.0003333 -73.410 2 0.0221930 90.426 3 0.0002218 164.994 4 0.0001666 -166.356 09:37:24 Move Stage, position = 0.000000