SLAC Magnetic Measurements Date: 01-06-2014 Time: 09:20:47 Project: Calibration_Magnets Magnet Type: Dipole Magnet Name: Pulsed_Wire_Horizontal Serial Number: Run Number: 6 Measurement Device: 10wire Operator: sda Comment: Integrated strength at 12 amps. After 5 min warmup Standardization for Main : 3 cycles from 0.0 A to 12.0 A to 0.0 A Test Currents for Main (A): 12.00 12.00 12.00 Integrated Dipole Strength Distance the wire was to be moved = 0.001000 m Number of turns in the wire = 1 Number of measurements for averaging = 9 Main +/- sigma BL sigBL BL/I sigBL/I (A) (A) (Tm) (Tm) (Tm/A) (Tm/A) ------------+---------- -------------+------------ -------------+------------- 12.0089 0.0002 -0.000764 0.000024 -6.36103e-05 2.03936e-06 12.0093 0.0000 -0.000752 0.000024 -6.26288e-05 1.97206e-06 12.0094 0.0000 -0.000757 0.000014 -6.30234e-05 1.18438e-06