SLAC Magnetic Measurements Date: 12-18-2013 Time: 15:26:54 Project: Calibration_Magnets Magnet Type: Dipole Magnet Name: Pulsed_Wire_Horizontal Serial Number: Run Number: 3 Measurement Device: 10wire Operator: sda Comment: Integrated strength from 0 to 12 amps in 1 amp steps. BL vs X at 12 amps. Standardization for Main : 3 cycles from 0.0 A to 12.0 A to 0.0 A Test Currents for Main (A): 0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 9.00 10.00 11.00 12.00 Integrated Dipole Strength Distance the wire was to be moved = 0.001000 m Number of turns in the wire = 1 Number of measurements for averaging = 6 Main +/- sigma BL sigBL BL/I sigBL/I (A) (A) (Tm) (Tm) (Tm/A) (Tm/A) ------------+---------- -------------+------------ -------------+------------- 0.0004 0.0000 0.000009 0.000012 0 0 1.0011 0.0000 -0.000055 0.000017 -5.50189e-05 1.73111e-05 2.0007 0.0000 -0.000103 0.000018 -5.1376e-05 9.17687e-06 3.0063 0.0000 -0.000152 0.000021 -5.04241e-05 6.96892e-06 4.0046 0.0000 -0.000233 0.000019 -5.81007e-05 4.7588e-06 5.0071 0.0000 -0.000290 0.000026 -5.78352e-05 5.14382e-06 6.0080 0.0000 -0.000369 0.000029 -6.14367e-05 4.81973e-06 7.0026 0.0000 -0.000411 0.000047 -5.87169e-05 6.77443e-06 8.0074 0.0000 -0.000492 0.000049 -6.14285e-05 6.08403e-06 9.0074 0.0000 -0.000583 0.000032 -6.46914e-05 3.58529e-06 10.0087 0.0000 -0.000623 0.000031 -6.22125e-05 3.10658e-06 11.0087 0.0001 -0.000697 0.000073 -6.33174e-05 6.64611e-06 12.0093 0.0001 -0.000778 0.000072 -6.47652e-05 5.97855e-06