SLAC Magnetic Measurements Date: 12-19-2013 Time: 11:00:11 Project: Calibration_Magnets Magnet Type: Dipole Magnet Name: Pulsed_Wire_Horizontal Serial Number: Run Number: 1 Measurement Device: 10wire Operator: sda Comment: Integrated strength from 0 to 12 amps in 1 amp steps. BL vs X at 12 amps. Standardization for Main : 3 cycles from 0.0 A to 12.0 A to 0.0 A Test Currents for Main (A): 0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 9.00 10.00 11.00 12.00 Integrated Dipole Strength Distance the wire was to be moved = 0.001000 m Number of turns in the wire = 1 Number of measurements for averaging = 6 Main +/- sigma BL sigBL BL/I sigBL/I (A) (A) (Tm) (Tm) (Tm/A) (Tm/A) ------------+---------- -------------+------------ -------------+------------- 0.0005 0.0000 0.000021 0.000009 0 0 1.0012 0.0000 -0.000052 0.000016 -5.22691e-05 1.59922e-05 2.0007 0.0000 -0.000108 0.000021 -5.4151e-05 1.06821e-05 3.0064 0.0000 -0.000172 0.000015 -5.70979e-05 4.99092e-06 4.0047 0.0000 -0.000240 0.000016 -6.00301e-05 4.0805e-06 5.0073 0.0000 -0.000297 0.000024 -5.93214e-05 4.88909e-06 6.0081 0.0000 -0.000371 0.000016 -6.18307e-05 2.65067e-06 7.0028 0.0000 -0.000423 0.000010 -6.04705e-05 1.49051e-06 8.0076 0.0000 -0.000498 0.000007 -6.21531e-05 8.50073e-07 9.0075 0.0000 -0.000564 0.000025 -6.25911e-05 2.72015e-06 10.0088 0.0000 -0.000641 0.000017 -6.40301e-05 1.65518e-06 11.0088 0.0001 -0.000691 0.000010 -6.27287e-05 8.97466e-07 12.0094 0.0001 -0.000763 0.000018 -6.3539e-05 1.51892e-06