SLAC Magnetic Measurements Date: 01-07-2014 Time: 09:17:18 Project: Calibration_Magnets Magnet Type: Dipole Magnet Name: Pulsed_Wire_45_Magnet Serial Number: Run Number: 2 Measurement Device: 10wire Operator: sda Comment: Integrated strength from 0 to 12 amps in 1 amp steps. Magnetic measured with field horizontal. After 5 min warmup Standardization for Main : 3 cycles from 0.0 A to 12.0 A to 0.0 A Test Currents for Main (A): 12.00 12.00 12.00 09:17:41 Initial Zero Current Measurement for Main , Imag_zero = 0 A 09:17:41 Ambient Measurement Device(s) Being Used, type = None 09:17:41 Magnet Voltage Measurement Device(s) Being Used, type = None 09:17:42 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 09:17:42 XMAG Device(s) Being Used, type = None 09:17:42 Ambient Measurement Device(s) Being Used, type = HP34970 09:17:42 Magnet system Main current ramping to 12.0000 A... 09:23:17 Magnet Current for Main , Imag = 12.0093 A Vtrans = 1.000778 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:23:17 Magnet Voltage Measurement, V = 0.000000 V 09:23:18 Temperature Measurement, Probe Number = 0, T = 18.839000 C 09:23:18 Sensor Voltage Measurement, Sensor Number = 0, V = 1.516303 V 09:23:18 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.516303 (V, A, ohm, ...), Measured Value = 17.170876 (C, atm, Hz, ...) 09:23:19 Sensor Voltage Measurement, Sensor Number = 1, V = 1.531058 V 09:23:19 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.531058 (V, A, ohm, ...), Measured Value = 17.375801 (C, atm, Hz, ...) 09:23:20 Sensor Voltage Measurement, Sensor Number = 2, V = 1.003697 V 09:23:20 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.003697 (V, A, ohm, ...), Measured Value = 0.277298 (C, atm, Hz, ...) 09:23:20 Sensor Voltage Measurement, Sensor Number = 3, V = 1.000003 V 09:23:20 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.000003 (V, A, ohm, ...), Measured Value = 0.000247 (C, atm, Hz, ...) 09:23:21 Sensor Voltage Measurement, Sensor Number = 4, V = 0.029155 V 09:23:21 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = 0.029155 (V, A, ohm, ...), Measured Value = 0.004951 (C, atm, Hz, ...) 09:23:21 Magnet Test Parameter Measurements P0 = Main , Value = 12.01 P1 = Magnet voltage (V), Value = 0.00 P2 = Ambient, Value = 18.84 P3 = Supply Temp(C), Value = 17.17 P4 = Return Temp(C), Value = 17.38 P5 = Supply Pres(psi), Value = 0.28 P6 = Return Pres(psi), Value = 0.00 P7 = Flow Rate(gpm), Value = 0.00 09:23:21 Magnet system Main current ramping to 0.0000 A... 09:23:55 Magnet system Main current ramping to 12.0000 A... 09:24:30 Magnet system Main current ramping to 0.0000 A... 09:25:04 Magnet system Main current ramping to 12.0000 A... 09:25:38 Magnet system Main current ramping to 0.0000 A... 09:26:13 Magnet system Main current ramping to 12.0000 A... 09:26:47 Magnet system Main current ramping to 0.0000 A... 09:27:33 Magnet system Main current ramping to 12.0000 A... 09:28:08 Magnet Current for Main , Imag = 12.0088 A Vtrans = 1.000733 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:28:08 Magnet Voltage Measurement, V = 0.000000 V 09:28:08 Temperature Measurement, Probe Number = 0, T = 18.832000 C 09:28:09 Sensor Voltage Measurement, Sensor Number = 0, V = 1.517373 V 09:28:09 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.517373 (V, A, ohm, ...), Measured Value = 17.185743 (C, atm, Hz, ...) 09:28:09 Sensor Voltage Measurement, Sensor Number = 1, V = 1.532076 V 09:28:09 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.532076 (V, A, ohm, ...), Measured Value = 17.389943 (C, atm, Hz, ...) 09:28:10 Sensor Voltage Measurement, Sensor Number = 2, V = 1.003750 V 09:28:10 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.003750 (V, A, ohm, ...), Measured Value = 0.281213 (C, atm, Hz, ...) 09:28:11 Sensor Voltage Measurement, Sensor Number = 3, V = 1.000166 V 09:28:11 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.000166 (V, A, ohm, ...), Measured Value = 0.012443 (C, atm, Hz, ...) 09:28:11 Sensor Voltage Measurement, Sensor Number = 4, V = 0.004238 V 09:28:11 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = 0.004238 (V, A, ohm, ...), Measured Value = 0.000720 (C, atm, Hz, ...) 09:28:11 Magnet Test Parameter Measurements P0 = Main , Value = 12.01 P1 = Magnet voltage (V), Value = 0.00 P2 = Ambient, Value = 18.83 P3 = Supply Temp(C), Value = 17.19 P4 = Return Temp(C), Value = 17.39 P5 = Supply Pres(psi), Value = 0.28 P6 = Return Pres(psi), Value = 0.01 P7 = Flow Rate(gpm), Value = 0.00 09:28:11 Magnetic Field Measurement Measuring the magnet strength... 09:28:11 Integrated Voltage Measurement... 09:28:12 Magnet Current for Main , Imag = 12.0088 A Vtrans = 1.000736 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:28:27 Voltage Offset Correction: v_off_ini = 0.000000416 V, v_off_fin = 0.000000269 V 09:28:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000806 Vs 09:28:42 Voltage Offset Correction: v_off_ini = 0.000000173 V, v_off_fin = 0.000000134 V 09:28:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000783 Vs 09:28:42 Magnet Current for Main , Imag = 12.0089 A Vtrans = 1.000742 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:28:57 Voltage Offset Correction: v_off_ini = 0.000000579 V, v_off_fin = 0.000000713 V 09:28:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000826 Vs 09:29:12 Voltage Offset Correction: v_off_ini = 0.000000359 V, v_off_fin = 0.000000387 V 09:29:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000774 Vs 09:29:13 Magnet Current for Main , Imag = 12.0090 A Vtrans = 1.000752 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:29:28 Voltage Offset Correction: v_off_ini = 0.000000385 V, v_off_fin = 0.000000386 V 09:29:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000854 Vs 09:29:43 Voltage Offset Correction: v_off_ini = 0.000000449 V, v_off_fin = 0.000000483 V 09:29:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000826 Vs 09:29:43 Magnet Current for Main , Imag = 12.0091 A Vtrans = 1.000759 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:29:58 Voltage Offset Correction: v_off_ini = 0.000000548 V, v_off_fin = 0.000000306 V 09:29:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000794 Vs 09:30:13 Voltage Offset Correction: v_off_ini = 0.000000557 V, v_off_fin = 0.000000642 V 09:30:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000851 Vs 09:30:14 Magnet Current for Main , Imag = 12.0092 A Vtrans = 1.000765 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:30:29 Voltage Offset Correction: v_off_ini = 0.000000320 V, v_off_fin = 0.000000231 V 09:30:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000831 Vs 09:30:44 Voltage Offset Correction: v_off_ini = 0.000000410 V, v_off_fin = 0.000000477 V 09:30:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000840 Vs 09:30:44 Magnet Current for Main , Imag = 12.0093 A Vtrans = 1.000772 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:30:59 Voltage Offset Correction: v_off_ini = 0.000000393 V, v_off_fin = 0.000000336 V 09:30:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000830 Vs 09:31:14 Voltage Offset Correction: v_off_ini = 0.000000525 V, v_off_fin = 0.000000490 V 09:31:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000749 Vs 09:31:15 Magnet Current for Main , Imag = 12.0093 A Vtrans = 1.000775 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:31:30 Voltage Offset Correction: v_off_ini = 0.000000600 V, v_off_fin = 0.000000615 V 09:31:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000812 Vs 09:31:45 Voltage Offset Correction: v_off_ini = 0.000000391 V, v_off_fin = 0.000000304 V 09:31:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000769 Vs 09:31:45 Magnet Current for Main , Imag = 12.0094 A Vtrans = 1.000781 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:32:00 Voltage Offset Correction: v_off_ini = 0.000000549 V, v_off_fin = 0.000000544 V 09:32:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000798 Vs 09:32:15 Voltage Offset Correction: v_off_ini = 0.000000323 V, v_off_fin = 0.000000359 V 09:32:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000786 Vs 09:32:16 Magnet Current for Main , Imag = 12.0094 A Vtrans = 1.000782 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:32:31 Voltage Offset Correction: v_off_ini = 0.000000464 V, v_off_fin = 0.000000356 V 09:32:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000822 Vs 09:32:46 Voltage Offset Correction: v_off_ini = 0.000000402 V, v_off_fin = 0.000000369 V 09:32:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000832 Vs 09:32:46 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000810 +- 0.000000020 Vs 09:32:46 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000810 +- 0.000000020 Vs BL = 0.00081013 +- 0.00001963 Tm 09:32:53 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00081 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00081 0.00002 0.00081 0.00000 09:32:53 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00081 0.00002 SL = 0.0008101 +- 0.0000196 Tm^2/m^n 09:32:53 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0008101 +- 0.0000196 Tm^2/m^n 09:33:00 Magnet system Main current ramping to 12.0000 A... 09:33:11 Magnet Current for Main , Imag = 12.0094 A Vtrans = 1.000786 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:33:11 Magnet Voltage Measurement, V = 0.000000 V 09:33:11 Temperature Measurement, Probe Number = 0, T = 18.830000 C 09:33:12 Sensor Voltage Measurement, Sensor Number = 0, V = 1.518646 V 09:33:12 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.518646 (V, A, ohm, ...), Measured Value = 17.203421 (C, atm, Hz, ...) 09:33:13 Sensor Voltage Measurement, Sensor Number = 1, V = 1.533122 V 09:33:13 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.533122 (V, A, ohm, ...), Measured Value = 17.404475 (C, atm, Hz, ...) 09:33:13 Sensor Voltage Measurement, Sensor Number = 2, V = 1.003792 V 09:33:13 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.003792 (V, A, ohm, ...), Measured Value = 0.284430 (C, atm, Hz, ...) 09:33:14 Sensor Voltage Measurement, Sensor Number = 3, V = 1.000185 V 09:33:14 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.000185 (V, A, ohm, ...), Measured Value = 0.013912 (C, atm, Hz, ...) 09:33:14 Sensor Voltage Measurement, Sensor Number = 4, V = 0.004296 V 09:33:14 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = 0.004296 (V, A, ohm, ...), Measured Value = 0.000730 (C, atm, Hz, ...) 09:33:14 Magnet Test Parameter Measurements P0 = Main , Value = 12.01 P1 = Magnet voltage (V), Value = 0.00 P2 = Ambient, Value = 18.83 P3 = Supply Temp(C), Value = 17.20 P4 = Return Temp(C), Value = 17.40 P5 = Supply Pres(psi), Value = 0.28 P6 = Return Pres(psi), Value = 0.01 P7 = Flow Rate(gpm), Value = 0.00 09:33:14 Magnetic Field Measurement Measuring the magnet strength... 09:33:14 Integrated Voltage Measurement... 09:33:15 Magnet Current for Main , Imag = 12.0094 A Vtrans = 1.000787 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:33:30 Voltage Offset Correction: v_off_ini = 0.000000394 V, v_off_fin = 0.000000426 V 09:33:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000809 Vs 09:33:45 Voltage Offset Correction: v_off_ini = 0.000000332 V, v_off_fin = 0.000000063 V 09:33:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000866 Vs 09:33:46 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000788 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:34:00 Voltage Offset Correction: v_off_ini = 0.000000596 V, v_off_fin = 0.000000515 V 09:34:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000780 Vs 09:34:15 Voltage Offset Correction: v_off_ini = 0.000000325 V, v_off_fin = 0.000000353 V 09:34:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000812 Vs 09:34:16 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000788 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:34:31 Voltage Offset Correction: v_off_ini = 0.000000490 V, v_off_fin = 0.000000584 V 09:34:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000809 Vs 09:34:46 Voltage Offset Correction: v_off_ini = 0.000000543 V, v_off_fin = 0.000000680 V 09:34:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000846 Vs 09:34:46 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000792 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:35:01 Voltage Offset Correction: v_off_ini = 0.000000516 V, v_off_fin = 0.000000542 V 09:35:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000838 Vs 09:35:16 Voltage Offset Correction: v_off_ini = 0.000000484 V, v_off_fin = 0.000000699 V 09:35:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000766 Vs 09:35:17 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000792 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:35:32 Voltage Offset Correction: v_off_ini = 0.000000477 V, v_off_fin = 0.000000454 V 09:35:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000784 Vs 09:35:47 Voltage Offset Correction: v_off_ini = 0.000000575 V, v_off_fin = 0.000000504 V 09:35:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000839 Vs 09:35:47 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000792 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:36:02 Voltage Offset Correction: v_off_ini = 0.000000518 V, v_off_fin = 0.000000643 V 09:36:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000809 Vs 09:36:17 Voltage Offset Correction: v_off_ini = 0.000000446 V, v_off_fin = 0.000000275 V 09:36:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000811 Vs 09:36:18 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000793 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:36:33 Voltage Offset Correction: v_off_ini = 0.000000586 V, v_off_fin = 0.000000627 V 09:36:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000791 Vs 09:36:47 Voltage Offset Correction: v_off_ini = 0.000000464 V, v_off_fin = 0.000000485 V 09:36:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000874 Vs 09:36:48 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000793 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:37:03 Voltage Offset Correction: v_off_ini = 0.000000408 V, v_off_fin = 0.000000632 V 09:37:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000763 Vs 09:37:18 Voltage Offset Correction: v_off_ini = 0.000000411 V, v_off_fin = 0.000000387 V 09:37:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000856 Vs 09:37:18 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000794 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:37:33 Voltage Offset Correction: v_off_ini = 0.000000550 V, v_off_fin = 0.000000560 V 09:37:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000830 Vs 09:37:48 Voltage Offset Correction: v_off_ini = 0.000000370 V, v_off_fin = 0.000000336 V 09:37:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000847 Vs 09:37:48 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000818 +- 0.000000015 Vs 09:37:48 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000818 +- 0.000000015 Vs BL = 0.00081842 +- 0.00001490 Tm 09:37:55 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00082 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00082 0.00001 0.00082 0.00000 09:37:55 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00082 0.00001 SL = 0.0008184 +- 0.0000149 Tm^2/m^n 09:37:55 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0008184 +- 0.0000149 Tm^2/m^n 09:38:02 Integrated Voltage Measurement... 09:38:03 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:38:18 Voltage Offset Correction: v_off_ini = 0.000000447 V, v_off_fin = 0.000000338 V 09:38:18 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = 0.0010000 m VT = 0.000000780 Vs 09:38:33 Voltage Offset Correction: v_off_ini = 0.000000466 V, v_off_fin = 0.000000447 V 09:38:33 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = -0.0010000 m VT = -0.000000816 Vs 09:38:34 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:38:48 Voltage Offset Correction: v_off_ini = 0.000000405 V, v_off_fin = 0.000000215 V 09:38:48 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = 0.0010000 m VT = 0.000000872 Vs 09:39:03 Voltage Offset Correction: v_off_ini = 0.000000394 V, v_off_fin = 0.000000373 V 09:39:03 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = -0.0010000 m VT = -0.000000750 Vs 09:39:04 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:39:19 Voltage Offset Correction: v_off_ini = 0.000000460 V, v_off_fin = 0.000000300 V 09:39:19 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = 0.0010000 m VT = 0.000000860 Vs 09:39:34 Voltage Offset Correction: v_off_ini = 0.000000508 V, v_off_fin = 0.000000288 V 09:39:34 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = -0.0010000 m VT = -0.000000808 Vs 09:39:34 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:39:49 Voltage Offset Correction: v_off_ini = 0.000000280 V, v_off_fin = 0.000000259 V 09:39:49 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = 0.0010000 m VT = 0.000000813 Vs 09:40:04 Voltage Offset Correction: v_off_ini = 0.000000503 V, v_off_fin = 0.000000479 V 09:40:04 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = -0.0010000 m VT = -0.000000880 Vs 09:40:05 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:40:20 Voltage Offset Correction: v_off_ini = 0.000000469 V, v_off_fin = 0.000000515 V 09:40:20 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = 0.0010000 m VT = 0.000000824 Vs 09:40:35 Voltage Offset Correction: v_off_ini = 0.000000332 V, v_off_fin = 0.000000628 V 09:40:35 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = -0.0010000 m VT = -0.000000807 Vs 09:40:35 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:40:50 Voltage Offset Correction: v_off_ini = 0.000000357 V, v_off_fin = 0.000000502 V 09:40:50 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = 0.0010000 m VT = 0.000000760 Vs 09:41:05 Voltage Offset Correction: v_off_ini = 0.000000297 V, v_off_fin = 0.000000238 V 09:41:05 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = -0.0010000 m VT = -0.000000788 Vs 09:41:06 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:41:21 Voltage Offset Correction: v_off_ini = 0.000000299 V, v_off_fin = 0.000000379 V 09:41:21 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = 0.0010000 m VT = 0.000000811 Vs 09:41:35 Voltage Offset Correction: v_off_ini = 0.000000187 V, v_off_fin = 0.000000322 V 09:41:35 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = -0.0010000 m VT = -0.000000829 Vs 09:41:36 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:41:51 Voltage Offset Correction: v_off_ini = 0.000000589 V, v_off_fin = 0.000000423 V 09:41:51 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = 0.0010000 m VT = 0.000000722 Vs 09:42:06 Voltage Offset Correction: v_off_ini = 0.000000407 V, v_off_fin = 0.000000082 V 09:42:06 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = -0.0010000 m VT = -0.000000720 Vs 09:42:07 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:42:21 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000222 V 09:42:21 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = 0.0010000 m VT = 0.000000804 Vs 09:42:36 Voltage Offset Correction: v_off_ini = 0.000000469 V, v_off_fin = 0.000000311 V 09:42:36 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = -0.0010000 m VT = -0.000000792 Vs 09:42:36 Integrated Voltage Average and RMS of Measurements X0 = -0.0040000 m, Delta X = 0.0010000 m VT = 0.000000802 +- 0.000000035 Vs 09:42:36 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0040000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000802 +- 0.000000035 Vs BL = 0.00080196 +- 0.00003486 Tm 09:42:36 Integrated Voltage Measurement... 09:42:37 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:42:52 Voltage Offset Correction: v_off_ini = 0.000000360 V, v_off_fin = 0.000000106 V 09:42:52 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = 0.0010000 m VT = 0.000000882 Vs 09:43:07 Voltage Offset Correction: v_off_ini = 0.000000443 V, v_off_fin = 0.000000693 V 09:43:07 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = -0.0010000 m VT = -0.000000928 Vs 09:43:07 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:43:22 Voltage Offset Correction: v_off_ini = 0.000000360 V, v_off_fin = 0.000000138 V 09:43:22 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = 0.0010000 m VT = 0.000000878 Vs 09:43:37 Voltage Offset Correction: v_off_ini = 0.000000421 V, v_off_fin = 0.000000482 V 09:43:37 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = -0.0010000 m VT = -0.000000839 Vs 09:43:38 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:43:53 Voltage Offset Correction: v_off_ini = 0.000000472 V, v_off_fin = 0.000000515 V 09:43:53 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = 0.0010000 m VT = 0.000000873 Vs 09:44:08 Voltage Offset Correction: v_off_ini = 0.000000293 V, v_off_fin = 0.000000384 V 09:44:08 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = -0.0010000 m VT = -0.000000773 Vs 09:44:08 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:44:23 Voltage Offset Correction: v_off_ini = 0.000000456 V, v_off_fin = 0.000000387 V 09:44:23 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = 0.0010000 m VT = 0.000000887 Vs 09:44:38 Voltage Offset Correction: v_off_ini = 0.000000305 V, v_off_fin = 0.000000034 V 09:44:38 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = -0.0010000 m VT = -0.000000818 Vs 09:44:39 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000794 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:44:54 Voltage Offset Correction: v_off_ini = 0.000000240 V, v_off_fin = 0.000000199 V 09:44:54 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = 0.0010000 m VT = 0.000000788 Vs 09:45:08 Voltage Offset Correction: v_off_ini = 0.000000446 V, v_off_fin = 0.000000188 V 09:45:08 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = -0.0010000 m VT = -0.000000760 Vs 09:45:09 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:45:24 Voltage Offset Correction: v_off_ini = 0.000000230 V, v_off_fin = 0.000000194 V 09:45:24 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = 0.0010000 m VT = 0.000000788 Vs 09:45:39 Voltage Offset Correction: v_off_ini = 0.000000306 V, v_off_fin = 0.000000315 V 09:45:39 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = -0.0010000 m VT = -0.000000823 Vs 09:45:39 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:45:54 Voltage Offset Correction: v_off_ini = 0.000000425 V, v_off_fin = 0.000000464 V 09:45:54 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = 0.0010000 m VT = 0.000000809 Vs 09:46:09 Voltage Offset Correction: v_off_ini = 0.000000471 V, v_off_fin = 0.000000446 V 09:46:09 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = -0.0010000 m VT = -0.000000792 Vs 09:46:10 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:46:25 Voltage Offset Correction: v_off_ini = 0.000000609 V, v_off_fin = 0.000000461 V 09:46:25 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = 0.0010000 m VT = 0.000000821 Vs 09:46:40 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000350 V 09:46:40 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = -0.0010000 m VT = -0.000000835 Vs 09:46:40 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:46:55 Voltage Offset Correction: v_off_ini = 0.000000422 V, v_off_fin = 0.000000481 V 09:46:55 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = 0.0010000 m VT = 0.000000833 Vs 09:47:10 Voltage Offset Correction: v_off_ini = 0.000000583 V, v_off_fin = 0.000000533 V 09:47:10 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = -0.0010000 m VT = -0.000000822 Vs 09:47:10 Integrated Voltage Average and RMS of Measurements X0 = -0.0030000 m, Delta X = 0.0010000 m VT = 0.000000831 +- 0.000000036 Vs 09:47:10 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0030000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000831 +- 0.000000036 Vs BL = 0.00083069 +- 0.00003596 Tm 09:47:10 Integrated Voltage Measurement... 09:47:11 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:47:26 Voltage Offset Correction: v_off_ini = 0.000000698 V, v_off_fin = 0.000000519 V 09:47:26 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = 0.0010000 m VT = 0.000000875 Vs 09:47:41 Voltage Offset Correction: v_off_ini = 0.000000415 V, v_off_fin = 0.000000492 V 09:47:41 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = -0.0010000 m VT = -0.000000804 Vs 09:47:41 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:47:56 Voltage Offset Correction: v_off_ini = 0.000000422 V, v_off_fin = 0.000000769 V 09:47:56 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = 0.0010000 m VT = 0.000000800 Vs 09:48:11 Voltage Offset Correction: v_off_ini = 0.000000506 V, v_off_fin = 0.000000416 V 09:48:11 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = -0.0010000 m VT = -0.000000824 Vs 09:48:12 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:48:27 Voltage Offset Correction: v_off_ini = 0.000000377 V, v_off_fin = 0.000000552 V 09:48:27 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = 0.0010000 m VT = 0.000000854 Vs 09:48:41 Voltage Offset Correction: v_off_ini = 0.000000591 V, v_off_fin = 0.000000176 V 09:48:41 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = -0.0010000 m VT = -0.000000911 Vs 09:48:42 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:48:57 Voltage Offset Correction: v_off_ini = 0.000000512 V, v_off_fin = 0.000000846 V 09:48:57 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = 0.0010000 m VT = 0.000000820 Vs 09:49:12 Voltage Offset Correction: v_off_ini = 0.000000494 V, v_off_fin = 0.000000554 V 09:49:12 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = -0.0010000 m VT = -0.000000864 Vs 09:49:12 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:49:27 Voltage Offset Correction: v_off_ini = 0.000000547 V, v_off_fin = 0.000000503 V 09:49:27 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = 0.0010000 m VT = 0.000000777 Vs 09:49:42 Voltage Offset Correction: v_off_ini = 0.000000415 V, v_off_fin = 0.000000310 V 09:49:42 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = -0.0010000 m VT = -0.000000807 Vs 09:49:43 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:49:58 Voltage Offset Correction: v_off_ini = 0.000000506 V, v_off_fin = 0.000000505 V 09:49:58 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = 0.0010000 m VT = 0.000000757 Vs 09:50:13 Voltage Offset Correction: v_off_ini = 0.000000520 V, v_off_fin = 0.000000467 V 09:50:13 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = -0.0010000 m VT = -0.000000805 Vs 09:50:13 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:50:28 Voltage Offset Correction: v_off_ini = 0.000000636 V, v_off_fin = 0.000000485 V 09:50:28 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = 0.0010000 m VT = 0.000000819 Vs 09:50:43 Voltage Offset Correction: v_off_ini = 0.000000373 V, v_off_fin = 0.000000319 V 09:50:43 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = -0.0010000 m VT = -0.000000795 Vs 09:50:44 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:50:59 Voltage Offset Correction: v_off_ini = 0.000000581 V, v_off_fin = 0.000000425 V 09:50:59 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = 0.0010000 m VT = 0.000000864 Vs 09:51:13 Voltage Offset Correction: v_off_ini = 0.000000533 V, v_off_fin = 0.000000658 V 09:51:13 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = -0.0010000 m VT = -0.000000838 Vs 09:51:14 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:51:29 Voltage Offset Correction: v_off_ini = 0.000000160 V, v_off_fin = 0.000000259 V 09:51:29 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = 0.0010000 m VT = 0.000000870 Vs 09:51:44 Voltage Offset Correction: v_off_ini = 0.000000539 V, v_off_fin = 0.000000519 V 09:51:44 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = -0.0010000 m VT = -0.000000857 Vs 09:51:44 Integrated Voltage Average and RMS of Measurements X0 = -0.0020000 m, Delta X = 0.0010000 m VT = 0.000000830 +- 0.000000032 Vs 09:51:44 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0020000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000830 +- 0.000000032 Vs BL = 0.00083000 +- 0.00003204 Tm 09:51:44 Integrated Voltage Measurement... 09:51:45 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:52:00 Voltage Offset Correction: v_off_ini = 0.000000357 V, v_off_fin = 0.000000205 V 09:52:00 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0010000 m VT = 0.000000888 Vs 09:52:14 Voltage Offset Correction: v_off_ini = 0.000000393 V, v_off_fin = 0.000000537 V 09:52:14 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0010000 m VT = -0.000000825 Vs 09:52:15 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:52:30 Voltage Offset Correction: v_off_ini = 0.000000402 V, v_off_fin = 0.000000373 V 09:52:30 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0010000 m VT = 0.000000832 Vs 09:52:45 Voltage Offset Correction: v_off_ini = 0.000000492 V, v_off_fin = 0.000000558 V 09:52:45 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0010000 m VT = -0.000000838 Vs 09:52:46 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000799 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:53:00 Voltage Offset Correction: v_off_ini = 0.000000698 V, v_off_fin = 0.000000767 V 09:53:00 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0010000 m VT = 0.000000801 Vs 09:53:15 Voltage Offset Correction: v_off_ini = 0.000000568 V, v_off_fin = 0.000000623 V 09:53:15 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0010000 m VT = -0.000000787 Vs 09:53:16 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:53:31 Voltage Offset Correction: v_off_ini = 0.000000446 V, v_off_fin = 0.000000745 V 09:53:31 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0010000 m VT = 0.000000847 Vs 09:53:46 Voltage Offset Correction: v_off_ini = 0.000000504 V, v_off_fin = 0.000000205 V 09:53:46 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0010000 m VT = -0.000000794 Vs 09:53:46 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:54:01 Voltage Offset Correction: v_off_ini = 0.000000511 V, v_off_fin = 0.000000759 V 09:54:01 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0010000 m VT = 0.000000790 Vs 09:54:16 Voltage Offset Correction: v_off_ini = 0.000000358 V, v_off_fin = 0.000000529 V 09:54:16 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0010000 m VT = -0.000000846 Vs 09:54:17 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:54:32 Voltage Offset Correction: v_off_ini = 0.000000513 V, v_off_fin = 0.000000674 V 09:54:32 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0010000 m VT = 0.000000795 Vs 09:54:47 Voltage Offset Correction: v_off_ini = 0.000000398 V, v_off_fin = 0.000000224 V 09:54:47 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0010000 m VT = -0.000000856 Vs 09:54:47 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:55:02 Voltage Offset Correction: v_off_ini = 0.000000416 V, v_off_fin = 0.000000517 V 09:55:02 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0010000 m VT = 0.000000815 Vs 09:55:17 Voltage Offset Correction: v_off_ini = 0.000000596 V, v_off_fin = 0.000000660 V 09:55:17 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0010000 m VT = -0.000000821 Vs 09:55:18 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:55:33 Voltage Offset Correction: v_off_ini = 0.000000402 V, v_off_fin = 0.000000431 V 09:55:33 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0010000 m VT = 0.000000815 Vs 09:55:48 Voltage Offset Correction: v_off_ini = 0.000000676 V, v_off_fin = 0.000000868 V 09:55:48 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0010000 m VT = -0.000000879 Vs 09:55:48 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000800 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:56:03 Voltage Offset Correction: v_off_ini = 0.000000337 V, v_off_fin = 0.000000441 V 09:56:03 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0010000 m VT = 0.000000825 Vs 09:56:18 Voltage Offset Correction: v_off_ini = -0.000000038 V, v_off_fin = -0.000000321 V 09:56:18 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0010000 m VT = -0.000000806 Vs 09:56:18 Integrated Voltage Average and RMS of Measurements X0 = -0.0010000 m, Delta X = 0.0010000 m VT = 0.000000826 +- 0.000000018 Vs 09:56:18 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0010000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000826 +- 0.000000018 Vs BL = 0.00082554 +- 0.00001750 Tm 09:56:18 Integrated Voltage Measurement... 09:56:19 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:56:34 Voltage Offset Correction: v_off_ini = 0.000000552 V, v_off_fin = 0.000000689 V 09:56:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000820 Vs 09:56:48 Voltage Offset Correction: v_off_ini = 0.000000371 V, v_off_fin = 0.000000392 V 09:56:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000802 Vs 09:56:49 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:57:04 Voltage Offset Correction: v_off_ini = 0.000000453 V, v_off_fin = 0.000000456 V 09:57:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000832 Vs 09:57:19 Voltage Offset Correction: v_off_ini = 0.000000382 V, v_off_fin = 0.000000278 V 09:57:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000825 Vs 09:57:19 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000799 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:57:34 Voltage Offset Correction: v_off_ini = 0.000000503 V, v_off_fin = 0.000000427 V 09:57:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000839 Vs 09:57:49 Voltage Offset Correction: v_off_ini = 0.000000284 V, v_off_fin = 0.000000284 V 09:57:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000752 Vs 09:57:50 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:58:05 Voltage Offset Correction: v_off_ini = 0.000000526 V, v_off_fin = 0.000000313 V 09:58:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000831 Vs 09:58:20 Voltage Offset Correction: v_off_ini = 0.000000477 V, v_off_fin = 0.000000328 V 09:58:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000813 Vs 09:58:20 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:58:35 Voltage Offset Correction: v_off_ini = 0.000000371 V, v_off_fin = 0.000000494 V 09:58:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000827 Vs 09:58:50 Voltage Offset Correction: v_off_ini = 0.000000355 V, v_off_fin = 0.000000437 V 09:58:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000792 Vs 09:58:51 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:59:06 Voltage Offset Correction: v_off_ini = 0.000000406 V, v_off_fin = 0.000000451 V 09:59:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000840 Vs 09:59:20 Voltage Offset Correction: v_off_ini = 0.000000581 V, v_off_fin = 0.000000819 V 09:59:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000760 Vs 09:59:21 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:59:36 Voltage Offset Correction: v_off_ini = 0.000000443 V, v_off_fin = 0.000000415 V 09:59:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000833 Vs 09:59:51 Voltage Offset Correction: v_off_ini = 0.000000598 V, v_off_fin = 0.000000535 V 09:59:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000837 Vs 09:59:52 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:00:07 Voltage Offset Correction: v_off_ini = 0.000000427 V, v_off_fin = 0.000000601 V 10:00:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000809 Vs 10:00:22 Voltage Offset Correction: v_off_ini = 0.000000208 V, v_off_fin = 0.000000241 V 10:00:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000800 Vs 10:00:23 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:00:38 Voltage Offset Correction: v_off_ini = 0.000000497 V, v_off_fin = 0.000000683 V 10:00:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000809 Vs 10:00:53 Voltage Offset Correction: v_off_ini = 0.000000342 V, v_off_fin = 0.000000268 V 10:00:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000847 Vs 10:00:53 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000815 +- 0.000000013 Vs 10:00:53 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000815 +- 0.000000013 Vs BL = 0.00081489 +- 0.00001317 Tm 10:00:53 Integrated Voltage Measurement... 10:00:54 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000794 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:01:08 Voltage Offset Correction: v_off_ini = 0.000000480 V, v_off_fin = 0.000000491 V 10:01:09 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0010000 m VT = 0.000000863 Vs 10:01:23 Voltage Offset Correction: v_off_ini = 0.000000357 V, v_off_fin = 0.000000508 V 10:01:23 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0010000 m VT = -0.000000789 Vs 10:01:24 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000794 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:01:39 Voltage Offset Correction: v_off_ini = 0.000000270 V, v_off_fin = 0.000000440 V 10:01:39 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0010000 m VT = 0.000000828 Vs 10:01:54 Voltage Offset Correction: v_off_ini = 0.000000489 V, v_off_fin = 0.000000735 V 10:01:54 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0010000 m VT = -0.000000871 Vs 10:01:55 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000792 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:02:10 Voltage Offset Correction: v_off_ini = 0.000000366 V, v_off_fin = 0.000000541 V 10:02:10 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0010000 m VT = 0.000000831 Vs 10:02:24 Voltage Offset Correction: v_off_ini = 0.000000279 V, v_off_fin = 0.000000504 V 10:02:24 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0010000 m VT = -0.000000855 Vs 10:02:25 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000793 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:02:40 Voltage Offset Correction: v_off_ini = 0.000000446 V, v_off_fin = 0.000000428 V 10:02:40 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0010000 m VT = 0.000000852 Vs 10:02:55 Voltage Offset Correction: v_off_ini = 0.000000306 V, v_off_fin = 0.000000227 V 10:02:55 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0010000 m VT = -0.000000813 Vs 10:02:56 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000792 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:03:10 Voltage Offset Correction: v_off_ini = 0.000000482 V, v_off_fin = 0.000000618 V 10:03:10 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0010000 m VT = 0.000000858 Vs 10:03:25 Voltage Offset Correction: v_off_ini = 0.000000335 V, v_off_fin = 0.000000423 V 10:03:25 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0010000 m VT = -0.000000844 Vs 10:03:26 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000792 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:03:41 Voltage Offset Correction: v_off_ini = 0.000000337 V, v_off_fin = 0.000000460 V 10:03:41 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0010000 m VT = 0.000000844 Vs 10:03:56 Voltage Offset Correction: v_off_ini = 0.000000328 V, v_off_fin = 0.000000340 V 10:03:56 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0010000 m VT = -0.000000842 Vs 10:03:56 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000793 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:04:11 Voltage Offset Correction: v_off_ini = 0.000000233 V, v_off_fin = 0.000000422 V 10:04:11 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0010000 m VT = 0.000000797 Vs 10:04:26 Voltage Offset Correction: v_off_ini = 0.000000098 V, v_off_fin = 0.000000248 V 10:04:26 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0010000 m VT = -0.000000773 Vs 10:04:27 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000792 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:04:42 Voltage Offset Correction: v_off_ini = 0.000000521 V, v_off_fin = 0.000000473 V 10:04:42 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0010000 m VT = 0.000000791 Vs 10:04:56 Voltage Offset Correction: v_off_ini = 0.000000595 V, v_off_fin = 0.000000979 V 10:04:56 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0010000 m VT = -0.000000858 Vs 10:04:57 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000793 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:05:12 Voltage Offset Correction: v_off_ini = 0.000000468 V, v_off_fin = 0.000000389 V 10:05:12 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0010000 m VT = 0.000000826 Vs 10:05:27 Voltage Offset Correction: v_off_ini = 0.000000315 V, v_off_fin = 0.000000353 V 10:05:27 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0010000 m VT = -0.000000857 Vs 10:05:27 Integrated Voltage Average and RMS of Measurements X0 = 0.0010000 m, Delta X = 0.0010000 m VT = 0.000000833 +- 0.000000019 Vs 10:05:27 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0010000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000833 +- 0.000000019 Vs BL = 0.00083284 +- 0.00001917 Tm 10:05:27 Integrated Voltage Measurement... 10:05:28 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000794 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:05:42 Voltage Offset Correction: v_off_ini = 0.000000158 V, v_off_fin = 0.000000250 V 10:05:42 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = 0.0010000 m VT = 0.000000829 Vs 10:05:57 Voltage Offset Correction: v_off_ini = 0.000000487 V, v_off_fin = 0.000000624 V 10:05:57 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = -0.0010000 m VT = -0.000000848 Vs 10:05:58 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000794 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:06:13 Voltage Offset Correction: v_off_ini = 0.000000410 V, v_off_fin = 0.000000324 V 10:06:13 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = 0.0010000 m VT = 0.000000820 Vs 10:06:28 Voltage Offset Correction: v_off_ini = 0.000000497 V, v_off_fin = 0.000000542 V 10:06:28 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = -0.0010000 m VT = -0.000000810 Vs 10:06:28 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:06:43 Voltage Offset Correction: v_off_ini = 0.000000416 V, v_off_fin = 0.000000212 V 10:06:43 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = 0.0010000 m VT = 0.000000831 Vs 10:06:58 Voltage Offset Correction: v_off_ini = 0.000000499 V, v_off_fin = 0.000000624 V 10:06:58 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = -0.0010000 m VT = -0.000000820 Vs 10:06:59 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000794 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:07:14 Voltage Offset Correction: v_off_ini = 0.000000326 V, v_off_fin = 0.000000155 V 10:07:14 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = 0.0010000 m VT = 0.000000829 Vs 10:07:29 Voltage Offset Correction: v_off_ini = 0.000000538 V, v_off_fin = 0.000000393 V 10:07:29 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = -0.0010000 m VT = -0.000000812 Vs 10:07:29 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000794 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:07:44 Voltage Offset Correction: v_off_ini = 0.000000205 V, v_off_fin = 0.000000027 V 10:07:44 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = 0.0010000 m VT = 0.000000835 Vs 10:07:59 Voltage Offset Correction: v_off_ini = 0.000000277 V, v_off_fin = 0.000000121 V 10:07:59 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = -0.0010000 m VT = -0.000000788 Vs 10:08:00 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000794 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:08:15 Voltage Offset Correction: v_off_ini = 0.000000281 V, v_off_fin = 0.000000055 V 10:08:15 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = 0.0010000 m VT = 0.000000767 Vs 10:08:29 Voltage Offset Correction: v_off_ini = 0.000000415 V, v_off_fin = 0.000000447 V 10:08:29 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = -0.0010000 m VT = -0.000000814 Vs 10:08:30 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000794 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:08:45 Voltage Offset Correction: v_off_ini = 0.000000283 V, v_off_fin = -0.000000010 V 10:08:45 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = 0.0010000 m VT = 0.000000761 Vs 10:09:00 Voltage Offset Correction: v_off_ini = 0.000000417 V, v_off_fin = 0.000000432 V 10:09:00 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = -0.0010000 m VT = -0.000000771 Vs 10:09:01 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:09:15 Voltage Offset Correction: v_off_ini = 0.000000479 V, v_off_fin = 0.000000539 V 10:09:15 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = 0.0010000 m VT = 0.000000821 Vs 10:09:30 Voltage Offset Correction: v_off_ini = 0.000000343 V, v_off_fin = 0.000000034 V 10:09:30 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = -0.0010000 m VT = -0.000000842 Vs 10:09:31 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:09:46 Voltage Offset Correction: v_off_ini = 0.000000369 V, v_off_fin = 0.000000237 V 10:09:46 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = 0.0010000 m VT = 0.000000917 Vs 10:10:01 Voltage Offset Correction: v_off_ini = 0.000000371 V, v_off_fin = 0.000000409 V 10:10:01 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = -0.0010000 m VT = -0.000000803 Vs 10:10:01 Integrated Voltage Average and RMS of Measurements X0 = 0.0020000 m, Delta X = 0.0010000 m VT = 0.000000818 +- 0.000000026 Vs 10:10:01 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0020000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000818 +- 0.000000026 Vs BL = 0.00081763 +- 0.00002579 Tm 10:10:01 Integrated Voltage Measurement... 10:10:01 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:10:16 Voltage Offset Correction: v_off_ini = 0.000000276 V, v_off_fin = 0.000000193 V 10:10:16 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = 0.0010000 m VT = 0.000000833 Vs 10:10:31 Voltage Offset Correction: v_off_ini = 0.000000443 V, v_off_fin = 0.000000286 V 10:10:31 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = -0.0010000 m VT = -0.000000819 Vs 10:10:32 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:10:47 Voltage Offset Correction: v_off_ini = 0.000000293 V, v_off_fin = 0.000000609 V 10:10:47 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = 0.0010000 m VT = 0.000000840 Vs 10:11:02 Voltage Offset Correction: v_off_ini = 0.000000315 V, v_off_fin = 0.000000514 V 10:11:02 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = -0.0010000 m VT = -0.000000798 Vs 10:11:02 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:11:17 Voltage Offset Correction: v_off_ini = 0.000000451 V, v_off_fin = 0.000000519 V 10:11:17 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = 0.0010000 m VT = 0.000000826 Vs 10:11:32 Voltage Offset Correction: v_off_ini = 0.000000518 V, v_off_fin = 0.000000412 V 10:11:32 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = -0.0010000 m VT = -0.000000869 Vs 10:11:33 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:11:48 Voltage Offset Correction: v_off_ini = 0.000000159 V, v_off_fin = 0.000000103 V 10:11:48 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = 0.0010000 m VT = 0.000000832 Vs 10:12:02 Voltage Offset Correction: v_off_ini = 0.000000570 V, v_off_fin = 0.000000503 V 10:12:02 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = -0.0010000 m VT = -0.000000855 Vs 10:12:03 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:12:18 Voltage Offset Correction: v_off_ini = 0.000000440 V, v_off_fin = 0.000000590 V 10:12:18 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = 0.0010000 m VT = 0.000000801 Vs 10:12:33 Voltage Offset Correction: v_off_ini = 0.000000415 V, v_off_fin = 0.000000650 V 10:12:33 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = -0.0010000 m VT = -0.000000807 Vs 10:12:34 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:12:48 Voltage Offset Correction: v_off_ini = 0.000000256 V, v_off_fin = 0.000000423 V 10:12:48 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = 0.0010000 m VT = 0.000000800 Vs 10:13:03 Voltage Offset Correction: v_off_ini = 0.000000455 V, v_off_fin = 0.000000345 V 10:13:03 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = -0.0010000 m VT = -0.000000835 Vs 10:13:04 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:13:19 Voltage Offset Correction: v_off_ini = 0.000000629 V, v_off_fin = 0.000000440 V 10:13:19 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = 0.0010000 m VT = 0.000000792 Vs 10:13:34 Voltage Offset Correction: v_off_ini = 0.000000423 V, v_off_fin = 0.000000333 V 10:13:34 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = -0.0010000 m VT = -0.000000812 Vs 10:13:34 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:13:49 Voltage Offset Correction: v_off_ini = 0.000000215 V, v_off_fin = 0.000000625 V 10:13:49 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = 0.0010000 m VT = 0.000000855 Vs 10:14:04 Voltage Offset Correction: v_off_ini = 0.000000181 V, v_off_fin = 0.000000276 V 10:14:04 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = -0.0010000 m VT = -0.000000849 Vs 10:14:05 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:14:20 Voltage Offset Correction: v_off_ini = 0.000000348 V, v_off_fin = 0.000000517 V 10:14:20 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = 0.0010000 m VT = 0.000000818 Vs 10:14:35 Voltage Offset Correction: v_off_ini = 0.000000407 V, v_off_fin = 0.000000377 V 10:14:35 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = -0.0010000 m VT = -0.000000829 Vs 10:14:35 Integrated Voltage Average and RMS of Measurements X0 = 0.0030000 m, Delta X = 0.0010000 m VT = 0.000000826 +- 0.000000017 Vs 10:14:35 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0030000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000826 +- 0.000000017 Vs BL = 0.00082609 +- 0.00001702 Tm 10:14:35 Integrated Voltage Measurement... 10:14:35 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:14:50 Voltage Offset Correction: v_off_ini = 0.000000252 V, v_off_fin = 0.000000055 V 10:14:50 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = 0.0010000 m VT = 0.000000867 Vs 10:15:05 Voltage Offset Correction: v_off_ini = 0.000000522 V, v_off_fin = 0.000000340 V 10:15:05 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = -0.0010000 m VT = -0.000000817 Vs 10:15:06 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:15:21 Voltage Offset Correction: v_off_ini = 0.000000473 V, v_off_fin = 0.000000428 V 10:15:21 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = 0.0010000 m VT = 0.000000784 Vs 10:15:35 Voltage Offset Correction: v_off_ini = 0.000000223 V, v_off_fin = 0.000000591 V 10:15:35 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = -0.0010000 m VT = -0.000000804 Vs 10:15:36 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:15:51 Voltage Offset Correction: v_off_ini = 0.000000269 V, v_off_fin = 0.000000389 V 10:15:51 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = 0.0010000 m VT = 0.000000811 Vs 10:16:06 Voltage Offset Correction: v_off_ini = 0.000000226 V, v_off_fin = 0.000000481 V 10:16:06 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = -0.0010000 m VT = -0.000000805 Vs 10:16:07 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:16:21 Voltage Offset Correction: v_off_ini = 0.000000467 V, v_off_fin = 0.000000321 V 10:16:21 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = 0.0010000 m VT = 0.000000784 Vs 10:16:36 Voltage Offset Correction: v_off_ini = 0.000000564 V, v_off_fin = 0.000000178 V 10:16:36 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = -0.0010000 m VT = -0.000000853 Vs 10:16:37 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:16:52 Voltage Offset Correction: v_off_ini = 0.000000469 V, v_off_fin = 0.000000100 V 10:16:52 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = 0.0010000 m VT = 0.000000812 Vs 10:17:07 Voltage Offset Correction: v_off_ini = 0.000000438 V, v_off_fin = 0.000000575 V 10:17:07 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = -0.0010000 m VT = -0.000000806 Vs 10:17:07 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:17:22 Voltage Offset Correction: v_off_ini = 0.000000448 V, v_off_fin = 0.000000557 V 10:17:22 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = 0.0010000 m VT = 0.000000782 Vs 10:17:37 Voltage Offset Correction: v_off_ini = 0.000000322 V, v_off_fin = 0.000000225 V 10:17:37 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = -0.0010000 m VT = -0.000000796 Vs 10:17:38 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:17:53 Voltage Offset Correction: v_off_ini = 0.000000450 V, v_off_fin = 0.000000437 V 10:17:53 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = 0.0010000 m VT = 0.000000818 Vs 10:18:08 Voltage Offset Correction: v_off_ini = 0.000000475 V, v_off_fin = 0.000000601 V 10:18:08 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = -0.0010000 m VT = -0.000000857 Vs 10:18:08 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:18:23 Voltage Offset Correction: v_off_ini = 0.000000268 V, v_off_fin = 0.000000090 V 10:18:23 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = 0.0010000 m VT = 0.000000780 Vs 10:18:38 Voltage Offset Correction: v_off_ini = 0.000000374 V, v_off_fin = 0.000000775 V 10:18:38 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = -0.0010000 m VT = -0.000000821 Vs 10:18:39 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:18:54 Voltage Offset Correction: v_off_ini = 0.000000458 V, v_off_fin = 0.000000167 V 10:18:54 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = 0.0010000 m VT = 0.000000774 Vs 10:19:08 Voltage Offset Correction: v_off_ini = 0.000000101 V, v_off_fin = 0.000000313 V 10:19:08 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = -0.0010000 m VT = -0.000000767 Vs 10:19:08 Integrated Voltage Average and RMS of Measurements X0 = 0.0040000 m, Delta X = 0.0010000 m VT = 0.000000808 +- 0.000000022 Vs 10:19:08 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0040000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000808 +- 0.000000022 Vs BL = 0.00080779 +- 0.00002150 Tm 10:19:16 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:19:16 Magnet Voltage Measurement, V = 0.000000 V 10:19:17 Temperature Measurement, Probe Number = 0, T = 19.277000 C 10:19:17 Sensor Voltage Measurement, Sensor Number = 0, V = 1.533215 V 10:19:17 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.533215 (V, A, ohm, ...), Measured Value = 17.405760 (C, atm, Hz, ...) 10:19:18 Sensor Voltage Measurement, Sensor Number = 1, V = 1.545284 V 10:19:18 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.545284 (V, A, ohm, ...), Measured Value = 17.573394 (C, atm, Hz, ...) 10:19:19 Sensor Voltage Measurement, Sensor Number = 2, V = 1.003885 V 10:19:19 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.003885 (V, A, ohm, ...), Measured Value = 0.291360 (C, atm, Hz, ...) 10:19:19 Sensor Voltage Measurement, Sensor Number = 3, V = 1.000201 V 10:19:19 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.000201 (V, A, ohm, ...), Measured Value = 0.015068 (C, atm, Hz, ...) 10:19:20 Sensor Voltage Measurement, Sensor Number = 4, V = 0.004315 V 10:19:20 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = 0.004315 (V, A, ohm, ...), Measured Value = 0.000733 (C, atm, Hz, ...) 10:19:20 Magnet Test Parameter Measurements P0 = Main , Value = 12.01 P1 = Magnet voltage (V), Value = 0.00 P2 = Ambient, Value = 19.28 P3 = Supply Temp(C), Value = 17.41 P4 = Return Temp(C), Value = 17.57 P5 = Supply Pres(psi), Value = 0.29 P6 = Return Pres(psi), Value = 0.02 P7 = Flow Rate(gpm), Value = 0.00 10:19:20 Magnet system Main current ramping to 12.0000 A... 10:19:31 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:19:31 Magnet Voltage Measurement, V = 0.000000 V 10:19:32 Temperature Measurement, Probe Number = 0, T = 19.260000 C 10:19:32 Sensor Voltage Measurement, Sensor Number = 0, V = 1.533323 V 10:19:32 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.533323 (V, A, ohm, ...), Measured Value = 17.407267 (C, atm, Hz, ...) 10:19:33 Sensor Voltage Measurement, Sensor Number = 1, V = 1.545368 V 10:19:33 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.545368 (V, A, ohm, ...), Measured Value = 17.574549 (C, atm, Hz, ...) 10:19:33 Sensor Voltage Measurement, Sensor Number = 2, V = 1.003934 V 10:19:33 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.003934 (V, A, ohm, ...), Measured Value = 0.295080 (C, atm, Hz, ...) 10:19:34 Sensor Voltage Measurement, Sensor Number = 3, V = 1.000209 V 10:19:34 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.000209 (V, A, ohm, ...), Measured Value = 0.015668 (C, atm, Hz, ...) 10:19:34 Sensor Voltage Measurement, Sensor Number = 4, V = 0.004314 V 10:19:34 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = 0.004314 (V, A, ohm, ...), Measured Value = 0.000733 (C, atm, Hz, ...) 10:19:34 Magnet Test Parameter Measurements P0 = Main , Value = 12.01 P1 = Magnet voltage (V), Value = 0.00 P2 = Ambient, Value = 19.26 P3 = Supply Temp(C), Value = 17.41 P4 = Return Temp(C), Value = 17.57 P5 = Supply Pres(psi), Value = 0.30 P6 = Return Pres(psi), Value = 0.02 P7 = Flow Rate(gpm), Value = 0.00 10:19:34 Magnetic Field Measurement Measuring the magnet strength... 10:19:34 Integrated Voltage Measurement... 10:19:35 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000799 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:19:50 Voltage Offset Correction: v_off_ini = 0.000000291 V, v_off_fin = 0.000000050 V 10:19:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000829 Vs 10:20:05 Voltage Offset Correction: v_off_ini = 0.000000315 V, v_off_fin = 0.000000039 V 10:20:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000863 Vs 10:20:06 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000799 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:20:20 Voltage Offset Correction: v_off_ini = 0.000000431 V, v_off_fin = 0.000000556 V 10:20:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000799 Vs 10:20:35 Voltage Offset Correction: v_off_ini = 0.000000378 V, v_off_fin = 0.000000302 V 10:20:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000831 Vs 10:20:36 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:20:51 Voltage Offset Correction: v_off_ini = 0.000000555 V, v_off_fin = 0.000000513 V 10:20:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000827 Vs 10:21:06 Voltage Offset Correction: v_off_ini = 0.000000291 V, v_off_fin = 0.000000118 V 10:21:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000809 Vs 10:21:06 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:21:21 Voltage Offset Correction: v_off_ini = 0.000000276 V, v_off_fin = 0.000000304 V 10:21:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000802 Vs 10:21:36 Voltage Offset Correction: v_off_ini = 0.000000389 V, v_off_fin = 0.000000555 V 10:21:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000794 Vs 10:21:37 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:21:52 Voltage Offset Correction: v_off_ini = 0.000000233 V, v_off_fin = 0.000000214 V 10:21:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000781 Vs 10:22:07 Voltage Offset Correction: v_off_ini = 0.000000294 V, v_off_fin = 0.000000378 V 10:22:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000824 Vs 10:22:07 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:22:22 Voltage Offset Correction: v_off_ini = 0.000000410 V, v_off_fin = 0.000000278 V 10:22:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000833 Vs 10:22:37 Voltage Offset Correction: v_off_ini = 0.000000578 V, v_off_fin = 0.000000877 V 10:22:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000816 Vs 10:22:38 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:22:53 Voltage Offset Correction: v_off_ini = 0.000000382 V, v_off_fin = 0.000000791 V 10:22:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000771 Vs 10:23:08 Voltage Offset Correction: v_off_ini = 0.000000348 V, v_off_fin = 0.000000396 V 10:23:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000849 Vs 10:23:08 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:23:23 Voltage Offset Correction: v_off_ini = 0.000000434 V, v_off_fin = 0.000000571 V 10:23:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000782 Vs 10:23:38 Voltage Offset Correction: v_off_ini = 0.000000574 V, v_off_fin = 0.000000557 V 10:23:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000859 Vs 10:23:39 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:23:54 Voltage Offset Correction: v_off_ini = 0.000000340 V, v_off_fin = 0.000000441 V 10:23:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000827 Vs 10:24:09 Voltage Offset Correction: v_off_ini = 0.000000133 V, v_off_fin = 0.000000298 V 10:24:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000850 Vs 10:24:09 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000819 +- 0.000000015 Vs 10:24:09 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000819 +- 0.000000015 Vs BL = 0.00081923 +- 0.00001470 Tm 10:24:16 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00082 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00082 0.00001 0.00082 0.00000 10:24:16 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00082 0.00001 SL = 0.0008192 +- 0.0000147 Tm^2/m^n 10:24:16 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0008192 +- 0.0000147 Tm^2/m^n 10:24:23 Integrated Voltage Measurement... 10:24:23 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000799 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:24:38 Voltage Offset Correction: v_off_ini = 0.000000542 V, v_off_fin = 0.000000370 V 10:24:38 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = 0.0010000 m VT = 0.000000806 Vs 10:24:53 Voltage Offset Correction: v_off_ini = 0.000000720 V, v_off_fin = 0.000000643 V 10:24:53 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = -0.0010000 m VT = -0.000000799 Vs 10:24:54 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:25:09 Voltage Offset Correction: v_off_ini = 0.000000333 V, v_off_fin = 0.000000380 V 10:25:09 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = 0.0010000 m VT = 0.000000788 Vs 10:25:24 Voltage Offset Correction: v_off_ini = 0.000000491 V, v_off_fin = 0.000000383 V 10:25:24 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = -0.0010000 m VT = -0.000000800 Vs 10:25:24 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:25:39 Voltage Offset Correction: v_off_ini = 0.000000377 V, v_off_fin = 0.000000629 V 10:25:39 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = 0.0010000 m VT = 0.000000792 Vs 10:25:54 Voltage Offset Correction: v_off_ini = 0.000000157 V, v_off_fin = 0.000000432 V 10:25:54 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = -0.0010000 m VT = -0.000000862 Vs 10:25:55 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000800 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:26:10 Voltage Offset Correction: v_off_ini = 0.000000139 V, v_off_fin = 0.000000204 V 10:26:10 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = 0.0010000 m VT = 0.000000809 Vs 10:26:24 Voltage Offset Correction: v_off_ini = 0.000000275 V, v_off_fin = 0.000000207 V 10:26:24 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = -0.0010000 m VT = -0.000000822 Vs 10:26:25 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:26:40 Voltage Offset Correction: v_off_ini = 0.000000068 V, v_off_fin = -0.000000096 V 10:26:40 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = 0.0010000 m VT = 0.000000839 Vs 10:26:55 Voltage Offset Correction: v_off_ini = 0.000000265 V, v_off_fin = 0.000000655 V 10:26:55 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = -0.0010000 m VT = -0.000000843 Vs 10:26:56 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:27:10 Voltage Offset Correction: v_off_ini = 0.000000354 V, v_off_fin = 0.000000394 V 10:27:10 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = 0.0010000 m VT = 0.000000822 Vs 10:27:25 Voltage Offset Correction: v_off_ini = 0.000000373 V, v_off_fin = 0.000000349 V 10:27:25 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = -0.0010000 m VT = -0.000000822 Vs 10:27:26 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000799 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:27:41 Voltage Offset Correction: v_off_ini = 0.000000517 V, v_off_fin = 0.000000234 V 10:27:41 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = 0.0010000 m VT = 0.000000862 Vs 10:27:56 Voltage Offset Correction: v_off_ini = 0.000000177 V, v_off_fin = -0.000000075 V 10:27:56 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = -0.0010000 m VT = -0.000000814 Vs 10:27:56 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:28:11 Voltage Offset Correction: v_off_ini = 0.000000447 V, v_off_fin = 0.000000709 V 10:28:11 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = 0.0010000 m VT = 0.000000824 Vs 10:28:26 Voltage Offset Correction: v_off_ini = 0.000000322 V, v_off_fin = 0.000000499 V 10:28:26 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = -0.0010000 m VT = -0.000000843 Vs 10:28:27 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:28:42 Voltage Offset Correction: v_off_ini = 0.000000156 V, v_off_fin = 0.000000414 V 10:28:42 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = 0.0010000 m VT = 0.000000793 Vs 10:28:57 Voltage Offset Correction: v_off_ini = 0.000000311 V, v_off_fin = 0.000000459 V 10:28:57 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = -0.0010000 m VT = -0.000000838 Vs 10:28:57 Integrated Voltage Average and RMS of Measurements X0 = -0.0040000 m, Delta X = 0.0010000 m VT = 0.000000821 +- 0.000000015 Vs 10:28:57 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0040000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000821 +- 0.000000015 Vs BL = 0.00082088 +- 0.00001503 Tm 10:28:57 Integrated Voltage Measurement... 10:28:57 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:29:12 Voltage Offset Correction: v_off_ini = 0.000000373 V, v_off_fin = 0.000000454 V 10:29:12 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = 0.0010000 m VT = 0.000000842 Vs 10:29:27 Voltage Offset Correction: v_off_ini = 0.000000398 V, v_off_fin = 0.000000351 V 10:29:27 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = -0.0010000 m VT = -0.000000873 Vs 10:29:28 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:29:43 Voltage Offset Correction: v_off_ini = 0.000000360 V, v_off_fin = 0.000000298 V 10:29:43 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = 0.0010000 m VT = 0.000000728 Vs 10:29:57 Voltage Offset Correction: v_off_ini = 0.000000380 V, v_off_fin = 0.000000351 V 10:29:57 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = -0.0010000 m VT = -0.000000807 Vs 10:29:58 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:30:13 Voltage Offset Correction: v_off_ini = 0.000000472 V, v_off_fin = 0.000000504 V 10:30:13 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = 0.0010000 m VT = 0.000000804 Vs 10:30:28 Voltage Offset Correction: v_off_ini = 0.000000333 V, v_off_fin = 0.000000291 V 10:30:28 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = -0.0010000 m VT = -0.000000787 Vs 10:30:29 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:30:43 Voltage Offset Correction: v_off_ini = 0.000000391 V, v_off_fin = 0.000000301 V 10:30:43 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = 0.0010000 m VT = 0.000000865 Vs 10:30:58 Voltage Offset Correction: v_off_ini = 0.000000278 V, v_off_fin = 0.000000326 V 10:30:58 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = -0.0010000 m VT = -0.000000827 Vs 10:30:59 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:31:14 Voltage Offset Correction: v_off_ini = 0.000000287 V, v_off_fin = 0.000000283 V 10:31:14 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = 0.0010000 m VT = 0.000000838 Vs 10:31:29 Voltage Offset Correction: v_off_ini = 0.000000127 V, v_off_fin = 0.000000057 V 10:31:29 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = -0.0010000 m VT = -0.000000824 Vs 10:31:29 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000799 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:31:44 Voltage Offset Correction: v_off_ini = 0.000000453 V, v_off_fin = 0.000000216 V 10:31:44 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = 0.0010000 m VT = 0.000000876 Vs 10:31:59 Voltage Offset Correction: v_off_ini = 0.000000343 V, v_off_fin = 0.000000269 V 10:31:59 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = -0.0010000 m VT = -0.000000767 Vs 10:32:00 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:32:15 Voltage Offset Correction: v_off_ini = 0.000000161 V, v_off_fin = 0.000000359 V 10:32:15 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = 0.0010000 m VT = 0.000000775 Vs 10:32:30 Voltage Offset Correction: v_off_ini = 0.000000265 V, v_off_fin = 0.000000321 V 10:32:30 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = -0.0010000 m VT = -0.000000884 Vs 10:32:30 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:32:45 Voltage Offset Correction: v_off_ini = 0.000000040 V, v_off_fin = 0.000000351 V 10:32:45 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = 0.0010000 m VT = 0.000000875 Vs 10:33:00 Voltage Offset Correction: v_off_ini = 0.000000214 V, v_off_fin = -0.000000056 V 10:33:00 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = -0.0010000 m VT = -0.000000902 Vs 10:33:01 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000799 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:33:15 Voltage Offset Correction: v_off_ini = 0.000000293 V, v_off_fin = 0.000000448 V 10:33:15 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = 0.0010000 m VT = 0.000000812 Vs 10:33:30 Voltage Offset Correction: v_off_ini = 0.000000393 V, v_off_fin = 0.000000383 V 10:33:30 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = -0.0010000 m VT = -0.000000825 Vs 10:33:30 Integrated Voltage Average and RMS of Measurements X0 = -0.0030000 m, Delta X = 0.0010000 m VT = 0.000000828 +- 0.000000033 Vs 10:33:30 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0030000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000828 +- 0.000000033 Vs BL = 0.00082843 +- 0.00003282 Tm 10:33:30 Integrated Voltage Measurement... 10:33:31 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:33:46 Voltage Offset Correction: v_off_ini = 0.000000336 V, v_off_fin = 0.000000412 V 10:33:46 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = 0.0010000 m VT = 0.000000785 Vs 10:34:01 Voltage Offset Correction: v_off_ini = 0.000000258 V, v_off_fin = 0.000000198 V 10:34:01 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = -0.0010000 m VT = -0.000000804 Vs 10:34:01 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:34:16 Voltage Offset Correction: v_off_ini = 0.000000373 V, v_off_fin = 0.000000358 V 10:34:16 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = 0.0010000 m VT = 0.000000796 Vs 10:34:31 Voltage Offset Correction: v_off_ini = 0.000000338 V, v_off_fin = 0.000000504 V 10:34:31 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = -0.0010000 m VT = -0.000000893 Vs 10:34:32 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000799 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:34:47 Voltage Offset Correction: v_off_ini = 0.000000311 V, v_off_fin = 0.000000300 V 10:34:47 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = 0.0010000 m VT = 0.000000766 Vs 10:35:02 Voltage Offset Correction: v_off_ini = 0.000000381 V, v_off_fin = 0.000000556 V 10:35:02 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = -0.0010000 m VT = -0.000000887 Vs 10:35:02 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:35:17 Voltage Offset Correction: v_off_ini = 0.000000307 V, v_off_fin = 0.000000053 V 10:35:17 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = 0.0010000 m VT = 0.000000839 Vs 10:35:32 Voltage Offset Correction: v_off_ini = 0.000000274 V, v_off_fin = 0.000000159 V 10:35:32 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = -0.0010000 m VT = -0.000000749 Vs 10:35:33 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:35:48 Voltage Offset Correction: v_off_ini = 0.000000428 V, v_off_fin = 0.000000432 V 10:35:48 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = 0.0010000 m VT = 0.000000830 Vs 10:36:02 Voltage Offset Correction: v_off_ini = 0.000000263 V, v_off_fin = 0.000000544 V 10:36:02 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = -0.0010000 m VT = -0.000000821 Vs 10:36:03 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:36:18 Voltage Offset Correction: v_off_ini = 0.000000403 V, v_off_fin = 0.000000474 V 10:36:18 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = 0.0010000 m VT = 0.000000824 Vs 10:36:33 Voltage Offset Correction: v_off_ini = 0.000000499 V, v_off_fin = 0.000000152 V 10:36:33 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = -0.0010000 m VT = -0.000000825 Vs 10:36:34 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:36:48 Voltage Offset Correction: v_off_ini = 0.000000362 V, v_off_fin = 0.000000021 V 10:36:48 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = 0.0010000 m VT = 0.000000848 Vs 10:37:03 Voltage Offset Correction: v_off_ini = 0.000000257 V, v_off_fin = 0.000000231 V 10:37:03 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = -0.0010000 m VT = -0.000000786 Vs 10:37:04 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:37:19 Voltage Offset Correction: v_off_ini = 0.000000351 V, v_off_fin = 0.000000086 V 10:37:19 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = 0.0010000 m VT = 0.000000888 Vs 10:37:34 Voltage Offset Correction: v_off_ini = 0.000000351 V, v_off_fin = 0.000000239 V 10:37:34 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = -0.0010000 m VT = -0.000000764 Vs 10:37:34 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000799 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:37:49 Voltage Offset Correction: v_off_ini = 0.000000388 V, v_off_fin = -0.000000004 V 10:37:49 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = 0.0010000 m VT = 0.000000842 Vs 10:38:04 Voltage Offset Correction: v_off_ini = 0.000000176 V, v_off_fin = -0.000000164 V 10:38:04 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = -0.0010000 m VT = -0.000000722 Vs 10:38:04 Integrated Voltage Average and RMS of Measurements X0 = -0.0020000 m, Delta X = 0.0010000 m VT = 0.000000815 +- 0.000000019 Vs 10:38:04 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0020000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000815 +- 0.000000019 Vs BL = 0.00081498 +- 0.00001909 Tm 10:38:04 Integrated Voltage Measurement... 10:38:05 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:38:20 Voltage Offset Correction: v_off_ini = 0.000000346 V, v_off_fin = 0.000000473 V 10:38:20 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0010000 m VT = 0.000000866 Vs 10:38:35 Voltage Offset Correction: v_off_ini = 0.000000339 V, v_off_fin = 0.000000445 V 10:38:35 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0010000 m VT = -0.000000820 Vs 10:38:35 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000799 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:38:50 Voltage Offset Correction: v_off_ini = 0.000000411 V, v_off_fin = 0.000000422 V 10:38:50 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0010000 m VT = 0.000000930 Vs 10:39:05 Voltage Offset Correction: v_off_ini = 0.000000173 V, v_off_fin = 0.000000209 V 10:39:05 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0010000 m VT = -0.000000806 Vs 10:39:06 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:39:21 Voltage Offset Correction: v_off_ini = 0.000000369 V, v_off_fin = 0.000000233 V 10:39:21 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0010000 m VT = 0.000000875 Vs 10:39:35 Voltage Offset Correction: v_off_ini = 0.000000259 V, v_off_fin = 0.000000676 V 10:39:35 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0010000 m VT = -0.000000853 Vs 10:39:36 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000799 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:39:51 Voltage Offset Correction: v_off_ini = 0.000000204 V, v_off_fin = 0.000000185 V 10:39:51 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0010000 m VT = 0.000000816 Vs 10:40:06 Voltage Offset Correction: v_off_ini = 0.000000285 V, v_off_fin = 0.000000481 V 10:40:06 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0010000 m VT = -0.000000802 Vs 10:40:06 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:40:21 Voltage Offset Correction: v_off_ini = 0.000000374 V, v_off_fin = 0.000000338 V 10:40:21 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0010000 m VT = 0.000000805 Vs 10:40:36 Voltage Offset Correction: v_off_ini = 0.000000453 V, v_off_fin = 0.000000534 V 10:40:36 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0010000 m VT = -0.000000813 Vs 10:40:37 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000794 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:40:52 Voltage Offset Correction: v_off_ini = 0.000000380 V, v_off_fin = 0.000000619 V 10:40:52 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0010000 m VT = 0.000000789 Vs 10:41:07 Voltage Offset Correction: v_off_ini = 0.000000312 V, v_off_fin = 0.000000209 V 10:41:07 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0010000 m VT = -0.000000863 Vs 10:41:07 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000794 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:41:22 Voltage Offset Correction: v_off_ini = 0.000000309 V, v_off_fin = 0.000000495 V 10:41:22 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0010000 m VT = 0.000000828 Vs 10:41:37 Voltage Offset Correction: v_off_ini = 0.000000384 V, v_off_fin = 0.000000446 V 10:41:37 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0010000 m VT = -0.000000855 Vs 10:41:38 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000794 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:41:53 Voltage Offset Correction: v_off_ini = 0.000000618 V, v_off_fin = 0.000000434 V 10:41:53 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0010000 m VT = 0.000000833 Vs 10:42:07 Voltage Offset Correction: v_off_ini = 0.000000325 V, v_off_fin = 0.000000618 V 10:42:07 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0010000 m VT = -0.000000859 Vs 10:42:08 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000794 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:42:23 Voltage Offset Correction: v_off_ini = 0.000000404 V, v_off_fin = 0.000000312 V 10:42:23 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0010000 m VT = 0.000000768 Vs 10:42:38 Voltage Offset Correction: v_off_ini = 0.000000459 V, v_off_fin = 0.000000629 V 10:42:38 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0010000 m VT = -0.000000876 Vs 10:42:38 Integrated Voltage Average and RMS of Measurements X0 = -0.0010000 m, Delta X = 0.0010000 m VT = 0.000000837 +- 0.000000020 Vs 10:42:38 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0010000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000837 +- 0.000000020 Vs BL = 0.00083653 +- 0.00002031 Tm 10:42:38 Integrated Voltage Measurement... 10:42:39 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:42:53 Voltage Offset Correction: v_off_ini = 0.000000285 V, v_off_fin = 0.000000029 V 10:42:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000797 Vs 10:43:08 Voltage Offset Correction: v_off_ini = 0.000000363 V, v_off_fin = 0.000000727 V 10:43:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000841 Vs 10:43:09 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000794 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:43:24 Voltage Offset Correction: v_off_ini = 0.000000377 V, v_off_fin = 0.000000405 V 10:43:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000826 Vs 10:43:39 Voltage Offset Correction: v_off_ini = 0.000000357 V, v_off_fin = 0.000000570 V 10:43:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000893 Vs 10:43:39 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000793 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:43:54 Voltage Offset Correction: v_off_ini = 0.000000549 V, v_off_fin = 0.000000670 V 10:43:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000792 Vs 10:44:09 Voltage Offset Correction: v_off_ini = 0.000000263 V, v_off_fin = 0.000000361 V 10:44:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000824 Vs 10:44:10 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:44:25 Voltage Offset Correction: v_off_ini = 0.000000408 V, v_off_fin = 0.000000648 V 10:44:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000811 Vs 10:44:40 Voltage Offset Correction: v_off_ini = 0.000000307 V, v_off_fin = 0.000000237 V 10:44:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000805 Vs 10:44:40 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:44:55 Voltage Offset Correction: v_off_ini = 0.000000438 V, v_off_fin = 0.000000550 V 10:44:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000809 Vs 10:45:10 Voltage Offset Correction: v_off_ini = 0.000000382 V, v_off_fin = 0.000000223 V 10:45:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000825 Vs 10:45:11 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:45:25 Voltage Offset Correction: v_off_ini = 0.000000478 V, v_off_fin = 0.000000503 V 10:45:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000805 Vs 10:45:40 Voltage Offset Correction: v_off_ini = 0.000000283 V, v_off_fin = 0.000000274 V 10:45:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000803 Vs 10:45:41 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:45:56 Voltage Offset Correction: v_off_ini = 0.000000331 V, v_off_fin = 0.000000158 V 10:45:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000859 Vs 10:46:11 Voltage Offset Correction: v_off_ini = 0.000000406 V, v_off_fin = 0.000000525 V 10:46:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000813 Vs 10:46:11 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:46:26 Voltage Offset Correction: v_off_ini = 0.000000314 V, v_off_fin = 0.000000550 V 10:46:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000801 Vs 10:46:41 Voltage Offset Correction: v_off_ini = 0.000000248 V, v_off_fin = 0.000000365 V 10:46:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000839 Vs 10:46:42 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:46:57 Voltage Offset Correction: v_off_ini = 0.000000164 V, v_off_fin = 0.000000458 V 10:46:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000834 Vs 10:47:12 Voltage Offset Correction: v_off_ini = 0.000000316 V, v_off_fin = 0.000000307 V 10:47:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000851 Vs 10:47:12 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000824 +- 0.000000018 Vs 10:47:12 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000824 +- 0.000000018 Vs BL = 0.00082383 +- 0.00001751 Tm 10:47:12 Integrated Voltage Measurement... 10:47:12 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:47:27 Voltage Offset Correction: v_off_ini = 0.000000346 V, v_off_fin = 0.000000273 V 10:47:27 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0010000 m VT = 0.000000828 Vs 10:47:42 Voltage Offset Correction: v_off_ini = 0.000000262 V, v_off_fin = 0.000000198 V 10:47:42 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0010000 m VT = -0.000000840 Vs 10:47:43 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:47:58 Voltage Offset Correction: v_off_ini = 0.000000237 V, v_off_fin = 0.000000188 V 10:47:58 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0010000 m VT = 0.000000786 Vs 10:48:12 Voltage Offset Correction: v_off_ini = 0.000000430 V, v_off_fin = 0.000000368 V 10:48:12 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0010000 m VT = -0.000000843 Vs 10:48:13 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:48:28 Voltage Offset Correction: v_off_ini = 0.000000380 V, v_off_fin = 0.000000987 V 10:48:28 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0010000 m VT = 0.000000828 Vs 10:48:43 Voltage Offset Correction: v_off_ini = 0.000000330 V, v_off_fin = 0.000000296 V 10:48:43 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0010000 m VT = -0.000000826 Vs 10:48:44 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000799 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:48:58 Voltage Offset Correction: v_off_ini = 0.000000227 V, v_off_fin = 0.000000090 V 10:48:58 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0010000 m VT = 0.000000844 Vs 10:49:13 Voltage Offset Correction: v_off_ini = 0.000000321 V, v_off_fin = 0.000000330 V 10:49:13 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0010000 m VT = -0.000000820 Vs 10:49:14 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:49:29 Voltage Offset Correction: v_off_ini = 0.000000311 V, v_off_fin = 0.000000001 V 10:49:29 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0010000 m VT = 0.000000814 Vs 10:49:44 Voltage Offset Correction: v_off_ini = 0.000000551 V, v_off_fin = 0.000000422 V 10:49:44 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0010000 m VT = -0.000000818 Vs 10:49:44 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:49:59 Voltage Offset Correction: v_off_ini = 0.000000158 V, v_off_fin = 0.000000171 V 10:49:59 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0010000 m VT = 0.000000802 Vs 10:50:14 Voltage Offset Correction: v_off_ini = 0.000000362 V, v_off_fin = 0.000000256 V 10:50:14 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0010000 m VT = -0.000000827 Vs 10:50:15 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:50:30 Voltage Offset Correction: v_off_ini = 0.000000481 V, v_off_fin = 0.000000380 V 10:50:30 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0010000 m VT = 0.000000788 Vs 10:50:45 Voltage Offset Correction: v_off_ini = 0.000000244 V, v_off_fin = 0.000000250 V 10:50:45 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0010000 m VT = -0.000000858 Vs 10:50:45 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000799 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:51:00 Voltage Offset Correction: v_off_ini = 0.000000308 V, v_off_fin = 0.000000338 V 10:51:00 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0010000 m VT = 0.000000875 Vs 10:51:15 Voltage Offset Correction: v_off_ini = 0.000000395 V, v_off_fin = 0.000000445 V 10:51:15 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0010000 m VT = -0.000000817 Vs 10:51:16 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:51:31 Voltage Offset Correction: v_off_ini = 0.000000182 V, v_off_fin = -0.000000026 V 10:51:31 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0010000 m VT = 0.000000864 Vs 10:51:45 Voltage Offset Correction: v_off_ini = 0.000000099 V, v_off_fin = 0.000000105 V 10:51:45 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0010000 m VT = -0.000000806 Vs 10:51:45 Integrated Voltage Average and RMS of Measurements X0 = 0.0010000 m, Delta X = 0.0010000 m VT = 0.000000827 +- 0.000000010 Vs 10:51:45 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0010000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000827 +- 0.000000010 Vs BL = 0.00082693 +- 0.00001019 Tm 10:51:45 Integrated Voltage Measurement... 10:51:46 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000800 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:52:01 Voltage Offset Correction: v_off_ini = 0.000000253 V, v_off_fin = 0.000000387 V 10:52:01 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = 0.0010000 m VT = 0.000000844 Vs 10:52:16 Voltage Offset Correction: v_off_ini = 0.000000308 V, v_off_fin = 0.000000161 V 10:52:16 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = -0.0010000 m VT = -0.000000869 Vs 10:52:17 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000800 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:52:31 Voltage Offset Correction: v_off_ini = 0.000000422 V, v_off_fin = 0.000000520 V 10:52:31 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = 0.0010000 m VT = 0.000000766 Vs 10:52:46 Voltage Offset Correction: v_off_ini = 0.000000194 V, v_off_fin = 0.000000298 V 10:52:46 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = -0.0010000 m VT = -0.000000797 Vs 10:52:47 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000800 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:53:02 Voltage Offset Correction: v_off_ini = 0.000000378 V, v_off_fin = 0.000000430 V 10:53:02 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = 0.0010000 m VT = 0.000000857 Vs 10:53:17 Voltage Offset Correction: v_off_ini = 0.000000238 V, v_off_fin = 0.000000602 V 10:53:17 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = -0.0010000 m VT = -0.000000849 Vs 10:53:17 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000800 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:53:32 Voltage Offset Correction: v_off_ini = 0.000000408 V, v_off_fin = 0.000000178 V 10:53:32 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = 0.0010000 m VT = 0.000000800 Vs 10:53:47 Voltage Offset Correction: v_off_ini = 0.000000297 V, v_off_fin = 0.000000490 V 10:53:47 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = -0.0010000 m VT = -0.000000762 Vs 10:53:48 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000800 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:54:03 Voltage Offset Correction: v_off_ini = 0.000000483 V, v_off_fin = 0.000000509 V 10:54:03 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = 0.0010000 m VT = 0.000000856 Vs 10:54:18 Voltage Offset Correction: v_off_ini = 0.000000381 V, v_off_fin = 0.000000390 V 10:54:18 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = -0.0010000 m VT = -0.000000804 Vs 10:54:18 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000799 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:54:33 Voltage Offset Correction: v_off_ini = 0.000000179 V, v_off_fin = 0.000000055 V 10:54:33 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = 0.0010000 m VT = 0.000000822 Vs 10:54:48 Voltage Offset Correction: v_off_ini = 0.000000460 V, v_off_fin = 0.000000191 V 10:54:48 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = -0.0010000 m VT = -0.000000774 Vs 10:54:49 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000800 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:55:04 Voltage Offset Correction: v_off_ini = 0.000000448 V, v_off_fin = 0.000000447 V 10:55:04 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = 0.0010000 m VT = 0.000000786 Vs 10:55:18 Voltage Offset Correction: v_off_ini = 0.000000443 V, v_off_fin = 0.000000335 V 10:55:18 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = -0.0010000 m VT = -0.000000782 Vs 10:55:19 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000800 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:55:34 Voltage Offset Correction: v_off_ini = 0.000000377 V, v_off_fin = 0.000000355 V 10:55:34 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = 0.0010000 m VT = 0.000000819 Vs 10:55:49 Voltage Offset Correction: v_off_ini = 0.000000091 V, v_off_fin = 0.000000092 V 10:55:49 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = -0.0010000 m VT = -0.000000829 Vs 10:55:50 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000800 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:56:04 Voltage Offset Correction: v_off_ini = 0.000000236 V, v_off_fin = 0.000000239 V 10:56:04 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = 0.0010000 m VT = 0.000000870 Vs 10:56:19 Voltage Offset Correction: v_off_ini = 0.000000155 V, v_off_fin = 0.000000133 V 10:56:19 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = -0.0010000 m VT = -0.000000842 Vs 10:56:19 Integrated Voltage Average and RMS of Measurements X0 = 0.0020000 m, Delta X = 0.0010000 m VT = 0.000000818 +- 0.000000031 Vs 10:56:19 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0020000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000818 +- 0.000000031 Vs BL = 0.00081829 +- 0.00003103 Tm 10:56:19 Integrated Voltage Measurement... 10:56:20 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000800 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:56:35 Voltage Offset Correction: v_off_ini = 0.000000240 V, v_off_fin = -0.000000092 V 10:56:35 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = 0.0010000 m VT = 0.000000859 Vs 10:56:50 Voltage Offset Correction: v_off_ini = 0.000000510 V, v_off_fin = 0.000000384 V 10:56:50 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = -0.0010000 m VT = -0.000000851 Vs 10:56:50 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000801 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:57:05 Voltage Offset Correction: v_off_ini = 0.000000268 V, v_off_fin = 0.000000131 V 10:57:05 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = 0.0010000 m VT = 0.000000830 Vs 10:57:20 Voltage Offset Correction: v_off_ini = 0.000000522 V, v_off_fin = 0.000000451 V 10:57:20 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = -0.0010000 m VT = -0.000000965 Vs 10:57:21 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000800 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:57:36 Voltage Offset Correction: v_off_ini = 0.000000536 V, v_off_fin = 0.000000525 V 10:57:36 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = 0.0010000 m VT = 0.000000796 Vs 10:57:51 Voltage Offset Correction: v_off_ini = 0.000000299 V, v_off_fin = 0.000000069 V 10:57:51 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = -0.0010000 m VT = -0.000000819 Vs 10:57:51 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000800 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:58:06 Voltage Offset Correction: v_off_ini = 0.000000201 V, v_off_fin = -0.000000101 V 10:58:06 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = 0.0010000 m VT = 0.000000816 Vs 10:58:21 Voltage Offset Correction: v_off_ini = 0.000000308 V, v_off_fin = 0.000000379 V 10:58:21 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = -0.0010000 m VT = -0.000000770 Vs 10:58:22 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:58:36 Voltage Offset Correction: v_off_ini = 0.000000117 V, v_off_fin = 0.000000286 V 10:58:36 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = 0.0010000 m VT = 0.000000782 Vs 10:58:51 Voltage Offset Correction: v_off_ini = 0.000000611 V, v_off_fin = 0.000000353 V 10:58:51 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = -0.0010000 m VT = -0.000000914 Vs 10:58:52 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000799 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:59:07 Voltage Offset Correction: v_off_ini = 0.000000455 V, v_off_fin = 0.000000079 V 10:59:07 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = 0.0010000 m VT = 0.000000806 Vs 10:59:22 Voltage Offset Correction: v_off_ini = 0.000000446 V, v_off_fin = 0.000000322 V 10:59:22 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = -0.0010000 m VT = -0.000000852 Vs 10:59:22 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000799 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 10:59:37 Voltage Offset Correction: v_off_ini = 0.000000125 V, v_off_fin = -0.000000116 V 10:59:37 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = 0.0010000 m VT = 0.000000818 Vs 10:59:52 Voltage Offset Correction: v_off_ini = 0.000000510 V, v_off_fin = 0.000000320 V 10:59:52 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = -0.0010000 m VT = -0.000000823 Vs 10:59:53 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000800 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 11:00:08 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000001079 V 11:00:08 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = 0.0010000 m VT = 0.000000670 Vs 11:00:23 Voltage Offset Correction: v_off_ini = 0.000000314 V, v_off_fin = 0.000000287 V 11:00:23 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = -0.0010000 m VT = -0.000000918 Vs 11:00:23 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000802 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 11:00:38 Voltage Offset Correction: v_off_ini = 0.000000617 V, v_off_fin = 0.000000524 V 11:00:38 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = 0.0010000 m VT = 0.000000792 Vs 11:00:53 Voltage Offset Correction: v_off_ini = 0.000000437 V, v_off_fin = 0.000000430 V 11:00:53 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = -0.0010000 m VT = -0.000000817 Vs 11:00:53 Integrated Voltage Average and RMS of Measurements X0 = 0.0030000 m, Delta X = 0.0010000 m VT = 0.000000828 +- 0.000000032 Vs 11:00:53 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0030000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000828 +- 0.000000032 Vs BL = 0.00082761 +- 0.00003226 Tm 11:00:53 Integrated Voltage Measurement... 11:00:54 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000799 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 11:01:09 Voltage Offset Correction: v_off_ini = 0.000000323 V, v_off_fin = 0.000000412 V 11:01:09 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = 0.0010000 m VT = 0.000000851 Vs 11:01:23 Voltage Offset Correction: v_off_ini = 0.000000352 V, v_off_fin = 0.000000396 V 11:01:23 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = -0.0010000 m VT = -0.000000850 Vs 11:01:24 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000800 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 11:01:39 Voltage Offset Correction: v_off_ini = 0.000000235 V, v_off_fin = 0.000000370 V 11:01:39 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = 0.0010000 m VT = 0.000000754 Vs 11:01:54 Voltage Offset Correction: v_off_ini = 0.000000639 V, v_off_fin = 0.000000467 V 11:01:54 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = -0.0010000 m VT = -0.000000871 Vs 11:01:55 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000801 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 11:02:09 Voltage Offset Correction: v_off_ini = 0.000000524 V, v_off_fin = 0.000000762 V 11:02:09 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = 0.0010000 m VT = 0.000000816 Vs 11:02:24 Voltage Offset Correction: v_off_ini = 0.000000366 V, v_off_fin = -0.000000073 V 11:02:24 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = -0.0010000 m VT = -0.000000727 Vs 11:02:25 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000801 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 11:02:40 Voltage Offset Correction: v_off_ini = 0.000000191 V, v_off_fin = -0.000000239 V 11:02:40 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = 0.0010000 m VT = 0.000000899 Vs 11:02:55 Voltage Offset Correction: v_off_ini = 0.000000273 V, v_off_fin = 0.000000351 V 11:02:55 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = -0.0010000 m VT = -0.000000863 Vs 11:02:55 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000800 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 11:03:10 Voltage Offset Correction: v_off_ini = 0.000000296 V, v_off_fin = 0.000000177 V 11:03:10 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = 0.0010000 m VT = 0.000000828 Vs 11:03:25 Voltage Offset Correction: v_off_ini = 0.000000292 V, v_off_fin = 0.000000339 V 11:03:25 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = -0.0010000 m VT = -0.000000845 Vs 11:03:26 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 11:03:41 Voltage Offset Correction: v_off_ini = 0.000000582 V, v_off_fin = 0.000000237 V 11:03:41 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = 0.0010000 m VT = 0.000000798 Vs 11:03:56 Voltage Offset Correction: v_off_ini = 0.000000234 V, v_off_fin = 0.000000189 V 11:03:56 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = -0.0010000 m VT = -0.000000875 Vs 11:03:56 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000800 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 11:04:11 Voltage Offset Correction: v_off_ini = 0.000000442 V, v_off_fin = 0.000000792 V 11:04:11 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = 0.0010000 m VT = 0.000000828 Vs 11:04:26 Voltage Offset Correction: v_off_ini = 0.000000464 V, v_off_fin = 0.000000313 V 11:04:26 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = -0.0010000 m VT = -0.000000888 Vs 11:04:27 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000800 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 11:04:42 Voltage Offset Correction: v_off_ini = 0.000000543 V, v_off_fin = 0.000000214 V 11:04:42 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = 0.0010000 m VT = 0.000000771 Vs 11:04:57 Voltage Offset Correction: v_off_ini = 0.000000315 V, v_off_fin = 0.000000399 V 11:04:57 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = -0.0010000 m VT = -0.000000858 Vs 11:04:57 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000799 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 11:05:12 Voltage Offset Correction: v_off_ini = 0.000000367 V, v_off_fin = 0.000000459 V 11:05:12 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = 0.0010000 m VT = 0.000000903 Vs 11:05:27 Voltage Offset Correction: v_off_ini = 0.000000299 V, v_off_fin = 0.000000241 V 11:05:27 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = -0.0010000 m VT = -0.000000738 Vs 11:05:27 Integrated Voltage Average and RMS of Measurements X0 = 0.0040000 m, Delta X = 0.0010000 m VT = 0.000000831 +- 0.000000030 Vs 11:05:27 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0040000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000831 +- 0.000000030 Vs BL = 0.00083127 +- 0.00002967 Tm 11:05:35 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 11:05:35 Magnet Voltage Measurement, V = 0.000000 V 11:05:35 Temperature Measurement, Probe Number = 0, T = 19.714000 C 11:05:36 Sensor Voltage Measurement, Sensor Number = 0, V = 1.557282 V 11:05:36 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.557282 (V, A, ohm, ...), Measured Value = 17.740025 (C, atm, Hz, ...) 11:05:37 Sensor Voltage Measurement, Sensor Number = 1, V = 1.565709 V 11:05:37 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.565709 (V, A, ohm, ...), Measured Value = 17.857067 (C, atm, Hz, ...) 11:05:37 Sensor Voltage Measurement, Sensor Number = 2, V = 1.004382 V 11:05:37 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.004382 (V, A, ohm, ...), Measured Value = 0.328643 (C, atm, Hz, ...) 11:05:38 Sensor Voltage Measurement, Sensor Number = 3, V = 1.000585 V 11:05:38 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.000585 (V, A, ohm, ...), Measured Value = 0.043882 (C, atm, Hz, ...) 11:05:38 Sensor Voltage Measurement, Sensor Number = 4, V = 0.012404 V 11:05:38 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = 0.012404 (V, A, ohm, ...), Measured Value = 0.002107 (C, atm, Hz, ...) 11:05:38 Magnet Test Parameter Measurements P0 = Main , Value = 12.01 P1 = Magnet voltage (V), Value = 0.00 P2 = Ambient, Value = 19.71 P3 = Supply Temp(C), Value = 17.74 P4 = Return Temp(C), Value = 17.86 P5 = Supply Pres(psi), Value = 0.33 P6 = Return Pres(psi), Value = 0.04 P7 = Flow Rate(gpm), Value = 0.00 11:05:50 Magnet system Main current ramping to 0.0000 A...