SLAC Magnetic Measurements Date: 01-06-2014 Time: 16:26:12 Project: Calibration_Magnets Magnet Type: Dipole Magnet Name: Pulsed_Wire_45_Magnet Serial Number: Run Number: 1 Measurement Device: 10wire Operator: sda Comment: Integrated strength from 0 to 12 amps in 1 amp steps. Magnetic measured with field horizontal. After 20 stdz and 5 min warmup Standardization for Main : 3 cycles from 0.0 A to 12.0 A to 0.0 A Test Currents for Main (A): 0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 9.00 10.00 11.00 12.00 12.00 12.00 16:26:35 Initial Zero Current Measurement for Main , Imag_zero = 0 A 16:26:35 Ambient Measurement Device(s) Being Used, type = None 16:26:35 Magnet Voltage Measurement Device(s) Being Used, type = None 16:26:35 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 16:26:35 XMAG Device(s) Being Used, type = None 16:26:36 Ambient Measurement Device(s) Being Used, type = HP34970 16:26:36 Magnet system Main current ramping to 12.0000 A... 16:32:11 Magnet Current for Main , Imag = 12.0093 A Vtrans = 1.000776 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:32:11 Magnet Voltage Measurement, V = 0.000000 V 16:32:11 Temperature Measurement, Probe Number = 0, T = 20.428000 C 16:32:12 Sensor Voltage Measurement, Sensor Number = 0, V = 1.668698 V 16:32:12 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.668698 (V, A, ohm, ...), Measured Value = 19.287471 (C, atm, Hz, ...) 16:32:13 Sensor Voltage Measurement, Sensor Number = 1, V = 1.683422 V 16:32:13 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.683422 (V, A, ohm, ...), Measured Value = 19.491968 (C, atm, Hz, ...) 16:32:13 Sensor Voltage Measurement, Sensor Number = 2, V = 1.006382 V 16:32:13 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.006382 (V, A, ohm, ...), Measured Value = 0.478657 (C, atm, Hz, ...) 16:32:14 Sensor Voltage Measurement, Sensor Number = 3, V = 1.002516 V 16:32:14 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002516 (V, A, ohm, ...), Measured Value = 0.188670 (C, atm, Hz, ...) 16:32:15 Sensor Voltage Measurement, Sensor Number = 4, V = 0.004335 V 16:32:15 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = 0.004335 (V, A, ohm, ...), Measured Value = 0.000736 (C, atm, Hz, ...) 16:32:15 Magnet Test Parameter Measurements P0 = Main , Value = 12.01 P1 = Magnet voltage (V), Value = 0.00 P2 = Ambient, Value = 20.43 P3 = Supply Temp(C), Value = 19.29 P4 = Return Temp(C), Value = 19.49 P5 = Supply Pres(psi), Value = 0.48 P6 = Return Pres(psi), Value = 0.19 P7 = Flow Rate(gpm), Value = 0.00 16:32:15 Magnet system Main current ramping to 0.0000 A... 16:32:49 Magnet system Main current ramping to 12.0000 A... 16:33:23 Magnet system Main current ramping to 0.0000 A... 16:33:58 Magnet system Main current ramping to 12.0000 A... 16:34:32 Magnet system Main current ramping to 0.0000 A... 16:35:06 Magnet system Main current ramping to 12.0000 A... 16:35:41 Magnet system Main current ramping to 0.0000 A... 16:36:26 Magnet system Main current ramping to 0.0000 A... 16:36:37 Magnet Current for Main , Imag = 0.0005 A Vtrans = 0.000039 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:36:37 Magnet Voltage Measurement, V = 0.000000 V 16:36:38 Temperature Measurement, Probe Number = 0, T = 20.447000 C 16:36:39 Sensor Voltage Measurement, Sensor Number = 0, V = 1.668359 V 16:36:39 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.668359 (V, A, ohm, ...), Measured Value = 19.282763 (C, atm, Hz, ...) 16:36:39 Sensor Voltage Measurement, Sensor Number = 1, V = 1.683581 V 16:36:39 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.683581 (V, A, ohm, ...), Measured Value = 19.494182 (C, atm, Hz, ...) 16:36:40 Sensor Voltage Measurement, Sensor Number = 2, V = 1.006436 V 16:36:40 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.006436 (V, A, ohm, ...), Measured Value = 0.482677 (C, atm, Hz, ...) 16:36:40 Sensor Voltage Measurement, Sensor Number = 3, V = 1.002630 V 16:36:40 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002630 (V, A, ohm, ...), Measured Value = 0.197213 (C, atm, Hz, ...) 16:36:41 Sensor Voltage Measurement, Sensor Number = 4, V = 0.007134 V 16:36:41 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = 0.007134 (V, A, ohm, ...), Measured Value = 0.001212 (C, atm, Hz, ...) 16:36:41 Magnet Test Parameter Measurements P0 = Main , Value = 0.00 P1 = Magnet voltage (V), Value = 0.00 P2 = Ambient, Value = 20.45 P3 = Supply Temp(C), Value = 19.28 P4 = Return Temp(C), Value = 19.49 P5 = Supply Pres(psi), Value = 0.48 P6 = Return Pres(psi), Value = 0.20 P7 = Flow Rate(gpm), Value = 0.00 16:36:41 Magnetic Field Measurement Measuring the magnet strength... 16:36:41 Integrated Voltage Measurement... 16:36:42 Magnet Current for Main , Imag = 0.0005 A Vtrans = 0.000039 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:36:57 Voltage Offset Correction: v_off_ini = 0.000000369 V, v_off_fin = 0.000000502 V 16:36:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000042 Vs 16:37:11 Voltage Offset Correction: v_off_ini = 0.000000622 V, v_off_fin = 0.000000818 V 16:37:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000048 Vs 16:37:12 Magnet Current for Main , Imag = 0.0005 A Vtrans = 0.000038 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:37:27 Voltage Offset Correction: v_off_ini = 0.000000425 V, v_off_fin = 0.000000440 V 16:37:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000028 Vs 16:37:42 Voltage Offset Correction: v_off_ini = 0.000000186 V, v_off_fin = 0.000000231 V 16:37:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000054 Vs 16:37:42 Magnet Current for Main , Imag = 0.0005 A Vtrans = 0.000039 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:37:57 Voltage Offset Correction: v_off_ini = 0.000000600 V, v_off_fin = 0.000000562 V 16:37:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000030 Vs 16:38:12 Voltage Offset Correction: v_off_ini = 0.000000462 V, v_off_fin = 0.000000380 V 16:38:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000047 Vs 16:38:13 Magnet Current for Main , Imag = 0.0004 A Vtrans = 0.000037 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:38:28 Voltage Offset Correction: v_off_ini = 0.000000472 V, v_off_fin = 0.000000425 V 16:38:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000045 Vs 16:38:43 Voltage Offset Correction: v_off_ini = 0.000000414 V, v_off_fin = 0.000000473 V 16:38:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000049 Vs 16:38:43 Magnet Current for Main , Imag = 0.0005 A Vtrans = 0.000038 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:38:58 Voltage Offset Correction: v_off_ini = 0.000000327 V, v_off_fin = 0.000000094 V 16:38:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000047 Vs 16:39:13 Voltage Offset Correction: v_off_ini = 0.000000485 V, v_off_fin = -0.000000030 V 16:39:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000097 Vs 16:39:14 Magnet Current for Main , Imag = 0.0005 A Vtrans = 0.000039 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:39:29 Voltage Offset Correction: v_off_ini = 0.000000512 V, v_off_fin = 0.000000521 V 16:39:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000040 Vs 16:39:43 Voltage Offset Correction: v_off_ini = 0.000000532 V, v_off_fin = 0.000000297 V 16:39:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000085 Vs 16:39:44 Magnet Current for Main , Imag = 0.0005 A Vtrans = 0.000038 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:39:59 Voltage Offset Correction: v_off_ini = 0.000000515 V, v_off_fin = 0.000000561 V 16:39:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000059 Vs 16:40:14 Voltage Offset Correction: v_off_ini = 0.000000619 V, v_off_fin = 0.000000180 V 16:40:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000058 Vs 16:40:15 Magnet Current for Main , Imag = 0.0004 A Vtrans = 0.000037 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:40:29 Voltage Offset Correction: v_off_ini = 0.000000512 V, v_off_fin = 0.000000393 V 16:40:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000042 Vs 16:40:44 Voltage Offset Correction: v_off_ini = 0.000000297 V, v_off_fin = 0.000000309 V 16:40:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000082 Vs 16:40:45 Magnet Current for Main , Imag = 0.0004 A Vtrans = 0.000036 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:41:00 Voltage Offset Correction: v_off_ini = 0.000000436 V, v_off_fin = 0.000000728 V 16:41:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = -0.000000032 Vs 16:41:15 Voltage Offset Correction: v_off_ini = 0.000000531 V, v_off_fin = 0.000000602 V 16:41:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000045 Vs 16:41:15 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000048 +- 0.000000018 Vs 16:41:15 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000048 +- 0.000000018 Vs BL = 0.00004818 +- 0.00001815 Tm 16:41:22 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00005 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00005 0.00002 0.00005 0.00000 16:41:22 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00005 0.00002 SL = 0.0000482 +- 0.0000182 Tm^2/m^n 16:41:22 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0000482 +- 0.0000182 Tm^2/m^n 16:41:29 Magnet system Main current ramping to 1.0000 A... 16:41:42 Magnet Current for Main , Imag = 1.0011 A Vtrans = 0.083429 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:41:42 Magnet Voltage Measurement, V = 0.000000 V 16:41:43 Temperature Measurement, Probe Number = 0, T = 20.394000 C 16:41:44 Sensor Voltage Measurement, Sensor Number = 0, V = 1.667776 V 16:41:44 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.667776 (V, A, ohm, ...), Measured Value = 19.274668 (C, atm, Hz, ...) 16:41:44 Sensor Voltage Measurement, Sensor Number = 1, V = 1.683513 V 16:41:44 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.683513 (V, A, ohm, ...), Measured Value = 19.493233 (C, atm, Hz, ...) 16:41:45 Sensor Voltage Measurement, Sensor Number = 2, V = 1.006437 V 16:41:45 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.006437 (V, A, ohm, ...), Measured Value = 0.482783 (C, atm, Hz, ...) 16:41:45 Sensor Voltage Measurement, Sensor Number = 3, V = 1.002650 V 16:41:45 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002650 (V, A, ohm, ...), Measured Value = 0.198720 (C, atm, Hz, ...) 16:41:46 Sensor Voltage Measurement, Sensor Number = 4, V = 0.004271 V 16:41:46 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = 0.004271 (V, A, ohm, ...), Measured Value = 0.000725 (C, atm, Hz, ...) 16:41:46 Magnet Test Parameter Measurements P0 = Main , Value = 1.00 P1 = Magnet voltage (V), Value = 0.00 P2 = Ambient, Value = 20.39 P3 = Supply Temp(C), Value = 19.27 P4 = Return Temp(C), Value = 19.49 P5 = Supply Pres(psi), Value = 0.48 P6 = Return Pres(psi), Value = 0.20 P7 = Flow Rate(gpm), Value = 0.00 16:41:46 Magnetic Field Measurement Measuring the magnet strength... 16:41:46 Integrated Voltage Measurement... 16:41:47 Magnet Current for Main , Imag = 1.0012 A Vtrans = 0.083429 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:42:02 Voltage Offset Correction: v_off_ini = 0.000000727 V, v_off_fin = 0.000000424 V 16:42:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000117 Vs 16:42:16 Voltage Offset Correction: v_off_ini = 0.000000413 V, v_off_fin = 0.000000576 V 16:42:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000127 Vs 16:42:17 Magnet Current for Main , Imag = 1.0011 A Vtrans = 0.083428 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:42:32 Voltage Offset Correction: v_off_ini = 0.000000327 V, v_off_fin = 0.000000423 V 16:42:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000141 Vs 16:42:47 Voltage Offset Correction: v_off_ini = 0.000000395 V, v_off_fin = 0.000000347 V 16:42:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000103 Vs 16:42:48 Magnet Current for Main , Imag = 1.0012 A Vtrans = 0.083429 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:43:02 Voltage Offset Correction: v_off_ini = 0.000000436 V, v_off_fin = 0.000000499 V 16:43:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000094 Vs 16:43:17 Voltage Offset Correction: v_off_ini = 0.000000468 V, v_off_fin = 0.000000629 V 16:43:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000128 Vs 16:43:18 Magnet Current for Main , Imag = 1.0011 A Vtrans = 0.083428 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:43:33 Voltage Offset Correction: v_off_ini = 0.000000495 V, v_off_fin = 0.000000502 V 16:43:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000108 Vs 16:43:48 Voltage Offset Correction: v_off_ini = 0.000000353 V, v_off_fin = 0.000000272 V 16:43:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000106 Vs 16:43:48 Magnet Current for Main , Imag = 1.0011 A Vtrans = 0.083428 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:44:03 Voltage Offset Correction: v_off_ini = 0.000000509 V, v_off_fin = 0.000000620 V 16:44:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000146 Vs 16:44:18 Voltage Offset Correction: v_off_ini = 0.000000279 V, v_off_fin = 0.000000157 V 16:44:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000164 Vs 16:44:19 Magnet Current for Main , Imag = 1.0011 A Vtrans = 0.083428 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:44:34 Voltage Offset Correction: v_off_ini = 0.000000532 V, v_off_fin = 0.000000548 V 16:44:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000102 Vs 16:44:49 Voltage Offset Correction: v_off_ini = 0.000000410 V, v_off_fin = 0.000000291 V 16:44:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000125 Vs 16:44:49 Magnet Current for Main , Imag = 1.0011 A Vtrans = 0.083428 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:45:04 Voltage Offset Correction: v_off_ini = 0.000000535 V, v_off_fin = 0.000000356 V 16:45:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000123 Vs 16:45:19 Voltage Offset Correction: v_off_ini = 0.000000574 V, v_off_fin = 0.000000795 V 16:45:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000107 Vs 16:45:20 Magnet Current for Main , Imag = 1.0011 A Vtrans = 0.083428 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:45:35 Voltage Offset Correction: v_off_ini = 0.000000593 V, v_off_fin = 0.000000449 V 16:45:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000076 Vs 16:45:49 Voltage Offset Correction: v_off_ini = 0.000000503 V, v_off_fin = 0.000000588 V 16:45:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000105 Vs 16:45:50 Magnet Current for Main , Imag = 1.0011 A Vtrans = 0.083427 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:46:05 Voltage Offset Correction: v_off_ini = 0.000000577 V, v_off_fin = 0.000000253 V 16:46:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000083 Vs 16:46:20 Voltage Offset Correction: v_off_ini = 0.000000482 V, v_off_fin = 0.000000380 V 16:46:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000084 Vs 16:46:20 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000113 +- 0.000000019 Vs 16:46:20 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000113 +- 0.000000019 Vs BL = 0.00011325 +- 0.00001939 Tm 16:46:27 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00011 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00011 0.00002 0.00011 0.00000 16:46:27 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00011 0.00002 SL = 0.0001133 +- 0.0000194 Tm^2/m^n 16:46:27 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0001133 +- 0.0000194 Tm^2/m^n 16:46:34 Magnet system Main current ramping to 2.0000 A... 16:46:47 Magnet Current for Main , Imag = 2.0007 A Vtrans = 0.166724 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:46:47 Magnet Voltage Measurement, V = 0.000000 V 16:46:48 Temperature Measurement, Probe Number = 0, T = 20.449000 C 16:46:48 Sensor Voltage Measurement, Sensor Number = 0, V = 1.667113 V 16:46:48 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.667113 (V, A, ohm, ...), Measured Value = 19.265458 (C, atm, Hz, ...) 16:46:49 Sensor Voltage Measurement, Sensor Number = 1, V = 1.683653 V 16:46:49 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.683653 (V, A, ohm, ...), Measured Value = 19.495186 (C, atm, Hz, ...) 16:46:49 Sensor Voltage Measurement, Sensor Number = 2, V = 1.006464 V 16:46:49 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.006464 (V, A, ohm, ...), Measured Value = 0.484785 (C, atm, Hz, ...) 16:46:50 Sensor Voltage Measurement, Sensor Number = 3, V = 1.002585 V 16:46:50 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002585 (V, A, ohm, ...), Measured Value = 0.193898 (C, atm, Hz, ...) 16:46:51 Sensor Voltage Measurement, Sensor Number = 4, V = 0.004326 V 16:46:51 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = 0.004326 (V, A, ohm, ...), Measured Value = 0.000735 (C, atm, Hz, ...) 16:46:51 Magnet Test Parameter Measurements P0 = Main , Value = 2.00 P1 = Magnet voltage (V), Value = 0.00 P2 = Ambient, Value = 20.45 P3 = Supply Temp(C), Value = 19.27 P4 = Return Temp(C), Value = 19.50 P5 = Supply Pres(psi), Value = 0.48 P6 = Return Pres(psi), Value = 0.19 P7 = Flow Rate(gpm), Value = 0.00 16:46:51 Magnetic Field Measurement Measuring the magnet strength... 16:46:51 Integrated Voltage Measurement... 16:46:51 Magnet Current for Main , Imag = 2.0007 A Vtrans = 0.166724 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:47:06 Voltage Offset Correction: v_off_ini = 0.000000603 V, v_off_fin = 0.000000618 V 16:47:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000163 Vs 16:47:21 Voltage Offset Correction: v_off_ini = 0.000000375 V, v_off_fin = 0.000000321 V 16:47:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000153 Vs 16:47:22 Magnet Current for Main , Imag = 2.0007 A Vtrans = 0.166724 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:47:37 Voltage Offset Correction: v_off_ini = 0.000000622 V, v_off_fin = 0.000000844 V 16:47:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000216 Vs 16:47:52 Voltage Offset Correction: v_off_ini = 0.000000640 V, v_off_fin = 0.000000794 V 16:47:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000188 Vs 16:47:52 Magnet Current for Main , Imag = 2.0007 A Vtrans = 0.166724 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:48:07 Voltage Offset Correction: v_off_ini = 0.000000322 V, v_off_fin = 0.000000170 V 16:48:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000188 Vs 16:48:22 Voltage Offset Correction: v_off_ini = 0.000000411 V, v_off_fin = 0.000000492 V 16:48:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000200 Vs 16:48:23 Magnet Current for Main , Imag = 2.0007 A Vtrans = 0.166724 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:48:37 Voltage Offset Correction: v_off_ini = 0.000000420 V, v_off_fin = 0.000000600 V 16:48:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000156 Vs 16:48:52 Voltage Offset Correction: v_off_ini = 0.000000190 V, v_off_fin = 0.000000311 V 16:48:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000198 Vs 16:48:53 Magnet Current for Main , Imag = 2.0007 A Vtrans = 0.166723 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:49:08 Voltage Offset Correction: v_off_ini = 0.000000370 V, v_off_fin = 0.000000366 V 16:49:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000185 Vs 16:49:23 Voltage Offset Correction: v_off_ini = 0.000000490 V, v_off_fin = 0.000000569 V 16:49:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000186 Vs 16:49:23 Magnet Current for Main , Imag = 2.0007 A Vtrans = 0.166723 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:49:38 Voltage Offset Correction: v_off_ini = 0.000000329 V, v_off_fin = 0.000000417 V 16:49:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000151 Vs 16:49:53 Voltage Offset Correction: v_off_ini = 0.000000309 V, v_off_fin = 0.000000239 V 16:49:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000169 Vs 16:49:54 Magnet Current for Main , Imag = 2.0007 A Vtrans = 0.166724 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:50:09 Voltage Offset Correction: v_off_ini = 0.000000331 V, v_off_fin = 0.000000379 V 16:50:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000173 Vs 16:50:24 Voltage Offset Correction: v_off_ini = 0.000000462 V, v_off_fin = 0.000000536 V 16:50:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000179 Vs 16:50:24 Magnet Current for Main , Imag = 2.0007 A Vtrans = 0.166724 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:50:39 Voltage Offset Correction: v_off_ini = 0.000000422 V, v_off_fin = 0.000000471 V 16:50:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000128 Vs 16:50:54 Voltage Offset Correction: v_off_ini = 0.000000412 V, v_off_fin = 0.000000183 V 16:50:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000125 Vs 16:50:55 Magnet Current for Main , Imag = 2.0007 A Vtrans = 0.166724 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:51:10 Voltage Offset Correction: v_off_ini = 0.000000428 V, v_off_fin = 0.000000277 V 16:51:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000134 Vs 16:51:25 Voltage Offset Correction: v_off_ini = 0.000000203 V, v_off_fin = 0.000000442 V 16:51:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000183 Vs 16:51:25 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000171 +- 0.000000022 Vs 16:51:25 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000171 +- 0.000000022 Vs BL = 0.00017080 +- 0.00002161 Tm 16:51:32 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00017 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00017 0.00002 0.00017 0.00000 16:51:32 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00017 0.00002 SL = 0.0001708 +- 0.0000216 Tm^2/m^n 16:51:32 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0001708 +- 0.0000216 Tm^2/m^n 16:51:39 Magnet system Main current ramping to 3.0000 A... 16:51:52 Magnet Current for Main , Imag = 3.0064 A Vtrans = 0.250530 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:51:52 Magnet Voltage Measurement, V = 0.000000 V 16:51:52 Temperature Measurement, Probe Number = 0, T = 20.377000 C 16:51:53 Sensor Voltage Measurement, Sensor Number = 0, V = 1.666376 V 16:51:53 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.666376 (V, A, ohm, ...), Measured Value = 19.255224 (C, atm, Hz, ...) 16:51:54 Sensor Voltage Measurement, Sensor Number = 1, V = 1.683570 V 16:51:54 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.683570 (V, A, ohm, ...), Measured Value = 19.494033 (C, atm, Hz, ...) 16:51:54 Sensor Voltage Measurement, Sensor Number = 2, V = 1.006479 V 16:51:54 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.006479 (V, A, ohm, ...), Measured Value = 0.485895 (C, atm, Hz, ...) 16:51:55 Sensor Voltage Measurement, Sensor Number = 3, V = 1.002601 V 16:51:55 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002601 (V, A, ohm, ...), Measured Value = 0.195105 (C, atm, Hz, ...) 16:51:55 Sensor Voltage Measurement, Sensor Number = 4, V = 0.024518 V 16:51:55 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = 0.024518 (V, A, ohm, ...), Measured Value = 0.004164 (C, atm, Hz, ...) 16:51:55 Magnet Test Parameter Measurements P0 = Main , Value = 3.01 P1 = Magnet voltage (V), Value = 0.00 P2 = Ambient, Value = 20.38 P3 = Supply Temp(C), Value = 19.26 P4 = Return Temp(C), Value = 19.49 P5 = Supply Pres(psi), Value = 0.49 P6 = Return Pres(psi), Value = 0.20 P7 = Flow Rate(gpm), Value = 0.00 16:51:55 Magnetic Field Measurement Measuring the magnet strength... 16:51:55 Integrated Voltage Measurement... 16:51:56 Magnet Current for Main , Imag = 3.0063 A Vtrans = 0.250528 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:52:11 Voltage Offset Correction: v_off_ini = 0.000000456 V, v_off_fin = 0.000000309 V 16:52:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000218 Vs 16:52:26 Voltage Offset Correction: v_off_ini = 0.000000437 V, v_off_fin = 0.000000268 V 16:52:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000203 Vs 16:52:27 Magnet Current for Main , Imag = 3.0063 A Vtrans = 0.250528 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:52:41 Voltage Offset Correction: v_off_ini = 0.000000321 V, v_off_fin = 0.000000644 V 16:52:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000186 Vs 16:52:56 Voltage Offset Correction: v_off_ini = 0.000000429 V, v_off_fin = 0.000000414 V 16:52:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000248 Vs 16:52:57 Magnet Current for Main , Imag = 3.0063 A Vtrans = 0.250528 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:53:12 Voltage Offset Correction: v_off_ini = 0.000000346 V, v_off_fin = 0.000000330 V 16:53:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000240 Vs 16:53:27 Voltage Offset Correction: v_off_ini = 0.000000398 V, v_off_fin = 0.000000416 V 16:53:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000245 Vs 16:53:27 Magnet Current for Main , Imag = 3.0063 A Vtrans = 0.250528 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:53:42 Voltage Offset Correction: v_off_ini = 0.000000387 V, v_off_fin = 0.000000478 V 16:53:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000188 Vs 16:53:57 Voltage Offset Correction: v_off_ini = 0.000000322 V, v_off_fin = 0.000000244 V 16:53:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000146 Vs 16:53:58 Magnet Current for Main , Imag = 3.0063 A Vtrans = 0.250528 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:54:13 Voltage Offset Correction: v_off_ini = 0.000000533 V, v_off_fin = 0.000000535 V 16:54:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000258 Vs 16:54:28 Voltage Offset Correction: v_off_ini = 0.000000407 V, v_off_fin = 0.000000400 V 16:54:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000247 Vs 16:54:28 Magnet Current for Main , Imag = 3.0063 A Vtrans = 0.250527 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:54:43 Voltage Offset Correction: v_off_ini = 0.000000192 V, v_off_fin = 0.000000557 V 16:54:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000274 Vs 16:54:58 Voltage Offset Correction: v_off_ini = 0.000000299 V, v_off_fin = 0.000000457 V 16:54:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000211 Vs 16:54:59 Magnet Current for Main , Imag = 3.0063 A Vtrans = 0.250528 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:55:14 Voltage Offset Correction: v_off_ini = 0.000000165 V, v_off_fin = 0.000000005 V 16:55:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000168 Vs 16:55:28 Voltage Offset Correction: v_off_ini = 0.000000494 V, v_off_fin = 0.000000549 V 16:55:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000207 Vs 16:55:29 Magnet Current for Main , Imag = 3.0063 A Vtrans = 0.250527 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:55:44 Voltage Offset Correction: v_off_ini = 0.000000351 V, v_off_fin = 0.000000375 V 16:55:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000230 Vs 16:55:59 Voltage Offset Correction: v_off_ini = 0.000000410 V, v_off_fin = 0.000000492 V 16:55:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000227 Vs 16:55:59 Magnet Current for Main , Imag = 3.0063 A Vtrans = 0.250526 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:56:14 Voltage Offset Correction: v_off_ini = 0.000000239 V, v_off_fin = 0.000000426 V 16:56:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000194 Vs 16:56:29 Voltage Offset Correction: v_off_ini = 0.000000168 V, v_off_fin = 0.000000091 V 16:56:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000260 Vs 16:56:29 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000219 +- 0.000000026 Vs 16:56:29 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000219 +- 0.000000026 Vs BL = 0.00021944 +- 0.00002615 Tm 16:56:36 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00022 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00022 0.00003 0.00022 0.00000 16:56:36 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00022 0.00003 SL = 0.0002194 +- 0.0000261 Tm^2/m^n 16:56:36 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0002194 +- 0.0000261 Tm^2/m^n 16:56:43 Magnet system Main current ramping to 4.0000 A... 16:56:56 Magnet Current for Main , Imag = 4.0046 A Vtrans = 0.333716 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:56:56 Magnet Voltage Measurement, V = 0.000000 V 16:56:57 Temperature Measurement, Probe Number = 0, T = 20.315000 C 16:56:58 Sensor Voltage Measurement, Sensor Number = 0, V = 1.665655 V 16:56:58 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.665655 (V, A, ohm, ...), Measured Value = 19.245213 (C, atm, Hz, ...) 16:56:58 Sensor Voltage Measurement, Sensor Number = 1, V = 1.683408 V 16:56:58 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.683408 (V, A, ohm, ...), Measured Value = 19.491782 (C, atm, Hz, ...) 16:56:59 Sensor Voltage Measurement, Sensor Number = 2, V = 1.006484 V 16:56:59 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.006484 (V, A, ohm, ...), Measured Value = 0.486293 (C, atm, Hz, ...) 16:56:59 Sensor Voltage Measurement, Sensor Number = 3, V = 1.002638 V 16:56:59 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002638 (V, A, ohm, ...), Measured Value = 0.197813 (C, atm, Hz, ...) 16:57:00 Sensor Voltage Measurement, Sensor Number = 4, V = 0.004269 V 16:57:00 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = 0.004269 (V, A, ohm, ...), Measured Value = 0.000725 (C, atm, Hz, ...) 16:57:00 Magnet Test Parameter Measurements P0 = Main , Value = 4.00 P1 = Magnet voltage (V), Value = 0.00 P2 = Ambient, Value = 20.32 P3 = Supply Temp(C), Value = 19.25 P4 = Return Temp(C), Value = 19.49 P5 = Supply Pres(psi), Value = 0.49 P6 = Return Pres(psi), Value = 0.20 P7 = Flow Rate(gpm), Value = 0.00 16:57:00 Magnetic Field Measurement Measuring the magnet strength... 16:57:00 Integrated Voltage Measurement... 16:57:01 Magnet Current for Main , Imag = 4.0046 A Vtrans = 0.333718 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:57:16 Voltage Offset Correction: v_off_ini = 0.000000350 V, v_off_fin = 0.000000503 V 16:57:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000302 Vs 16:57:31 Voltage Offset Correction: v_off_ini = 0.000000313 V, v_off_fin = 0.000000428 V 16:57:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000298 Vs 16:57:31 Magnet Current for Main , Imag = 4.0046 A Vtrans = 0.333715 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:57:46 Voltage Offset Correction: v_off_ini = 0.000000336 V, v_off_fin = -0.000000182 V 16:57:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000320 Vs 16:58:01 Voltage Offset Correction: v_off_ini = 0.000000265 V, v_off_fin = 0.000000282 V 16:58:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000289 Vs 16:58:02 Magnet Current for Main , Imag = 4.0046 A Vtrans = 0.333716 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:58:17 Voltage Offset Correction: v_off_ini = 0.000000375 V, v_off_fin = 0.000000405 V 16:58:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000343 Vs 16:58:31 Voltage Offset Correction: v_off_ini = 0.000000322 V, v_off_fin = 0.000000251 V 16:58:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000269 Vs 16:58:32 Magnet Current for Main , Imag = 4.0046 A Vtrans = 0.333716 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:58:47 Voltage Offset Correction: v_off_ini = 0.000000392 V, v_off_fin = 0.000000152 V 16:58:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000324 Vs 16:59:02 Voltage Offset Correction: v_off_ini = 0.000000176 V, v_off_fin = 0.000000425 V 16:59:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000334 Vs 16:59:03 Magnet Current for Main , Imag = 4.0046 A Vtrans = 0.333716 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:59:17 Voltage Offset Correction: v_off_ini = 0.000000357 V, v_off_fin = 0.000000402 V 16:59:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000306 Vs 16:59:32 Voltage Offset Correction: v_off_ini = 0.000000459 V, v_off_fin = 0.000000291 V 16:59:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000279 Vs 16:59:33 Magnet Current for Main , Imag = 4.0046 A Vtrans = 0.333715 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 16:59:48 Voltage Offset Correction: v_off_ini = 0.000000350 V, v_off_fin = 0.000000026 V 16:59:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000268 Vs 17:00:03 Voltage Offset Correction: v_off_ini = 0.000000444 V, v_off_fin = 0.000000352 V 17:00:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000323 Vs 17:00:03 Magnet Current for Main , Imag = 4.0046 A Vtrans = 0.333716 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:00:18 Voltage Offset Correction: v_off_ini = 0.000000269 V, v_off_fin = 0.000000242 V 17:00:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000288 Vs 17:00:33 Voltage Offset Correction: v_off_ini = 0.000000192 V, v_off_fin = 0.000000246 V 17:00:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000299 Vs 17:00:34 Magnet Current for Main , Imag = 4.0046 A Vtrans = 0.333716 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:00:49 Voltage Offset Correction: v_off_ini = 0.000000233 V, v_off_fin = 0.000000124 V 17:00:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000255 Vs 17:01:04 Voltage Offset Correction: v_off_ini = 0.000000396 V, v_off_fin = 0.000000393 V 17:01:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000307 Vs 17:01:04 Magnet Current for Main , Imag = 4.0046 A Vtrans = 0.333714 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:01:19 Voltage Offset Correction: v_off_ini = 0.000000314 V, v_off_fin = 0.000000461 V 17:01:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000289 Vs 17:01:34 Voltage Offset Correction: v_off_ini = 0.000000394 V, v_off_fin = 0.000000436 V 17:01:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000322 Vs 17:01:34 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000301 +- 0.000000013 Vs 17:01:34 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000301 +- 0.000000013 Vs BL = 0.00030079 +- 0.00001253 Tm 17:01:41 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00030 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00030 0.00001 0.00030 0.00000 17:01:41 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00030 0.00001 SL = 0.0003008 +- 0.0000125 Tm^2/m^n 17:01:41 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0003008 +- 0.0000125 Tm^2/m^n 17:01:48 Magnet system Main current ramping to 5.0000 A... 17:02:01 Magnet Current for Main , Imag = 5.0072 A Vtrans = 0.417265 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:02:01 Magnet Voltage Measurement, V = 0.000000 V 17:02:02 Temperature Measurement, Probe Number = 0, T = 20.346000 C 17:02:03 Sensor Voltage Measurement, Sensor Number = 0, V = 1.664782 V 17:02:03 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.664782 (V, A, ohm, ...), Measured Value = 19.233081 (C, atm, Hz, ...) 17:02:03 Sensor Voltage Measurement, Sensor Number = 1, V = 1.683132 V 17:02:03 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.683132 (V, A, ohm, ...), Measured Value = 19.487949 (C, atm, Hz, ...) 17:02:04 Sensor Voltage Measurement, Sensor Number = 2, V = 1.006475 V 17:02:04 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.006475 (V, A, ohm, ...), Measured Value = 0.485595 (C, atm, Hz, ...) 17:02:04 Sensor Voltage Measurement, Sensor Number = 3, V = 1.002575 V 17:02:04 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002575 (V, A, ohm, ...), Measured Value = 0.193095 (C, atm, Hz, ...) 17:02:05 Sensor Voltage Measurement, Sensor Number = 4, V = 0.004261 V 17:02:05 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = 0.004261 (V, A, ohm, ...), Measured Value = 0.000724 (C, atm, Hz, ...) 17:02:05 Magnet Test Parameter Measurements P0 = Main , Value = 5.01 P1 = Magnet voltage (V), Value = 0.00 P2 = Ambient, Value = 20.35 P3 = Supply Temp(C), Value = 19.23 P4 = Return Temp(C), Value = 19.49 P5 = Supply Pres(psi), Value = 0.49 P6 = Return Pres(psi), Value = 0.19 P7 = Flow Rate(gpm), Value = 0.00 17:02:05 Magnetic Field Measurement Measuring the magnet strength... 17:02:05 Integrated Voltage Measurement... 17:02:06 Magnet Current for Main , Imag = 5.0072 A Vtrans = 0.417266 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:02:21 Voltage Offset Correction: v_off_ini = 0.000000358 V, v_off_fin = 0.000000384 V 17:02:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000366 Vs 17:02:35 Voltage Offset Correction: v_off_ini = 0.000000225 V, v_off_fin = 0.000000261 V 17:02:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000353 Vs 17:02:36 Magnet Current for Main , Imag = 5.0072 A Vtrans = 0.417265 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:02:51 Voltage Offset Correction: v_off_ini = 0.000000425 V, v_off_fin = 0.000000439 V 17:02:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000331 Vs 17:03:06 Voltage Offset Correction: v_off_ini = 0.000000346 V, v_off_fin = 0.000000326 V 17:03:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000379 Vs 17:03:07 Magnet Current for Main , Imag = 5.0072 A Vtrans = 0.417266 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:03:21 Voltage Offset Correction: v_off_ini = 0.000000316 V, v_off_fin = 0.000000738 V 17:03:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000357 Vs 17:03:36 Voltage Offset Correction: v_off_ini = 0.000000095 V, v_off_fin = 0.000000016 V 17:03:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000333 Vs 17:03:37 Magnet Current for Main , Imag = 5.0072 A Vtrans = 0.417265 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:03:52 Voltage Offset Correction: v_off_ini = 0.000000401 V, v_off_fin = 0.000000440 V 17:03:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000478 Vs 17:04:07 Voltage Offset Correction: v_off_ini = 0.000000380 V, v_off_fin = 0.000000324 V 17:04:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000330 Vs 17:04:07 Magnet Current for Main , Imag = 5.0072 A Vtrans = 0.417265 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:04:22 Voltage Offset Correction: v_off_ini = 0.000000349 V, v_off_fin = 0.000000324 V 17:04:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000327 Vs 17:04:37 Voltage Offset Correction: v_off_ini = 0.000000342 V, v_off_fin = 0.000000384 V 17:04:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000391 Vs 17:04:38 Magnet Current for Main , Imag = 5.0072 A Vtrans = 0.417264 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:04:53 Voltage Offset Correction: v_off_ini = 0.000000280 V, v_off_fin = 0.000000334 V 17:04:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000351 Vs 17:05:08 Voltage Offset Correction: v_off_ini = 0.000000240 V, v_off_fin = 0.000000227 V 17:05:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000382 Vs 17:05:08 Magnet Current for Main , Imag = 5.0072 A Vtrans = 0.417265 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:05:23 Voltage Offset Correction: v_off_ini = 0.000000164 V, v_off_fin = 0.000000203 V 17:05:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000338 Vs 17:05:38 Voltage Offset Correction: v_off_ini = 0.000000123 V, v_off_fin = 0.000000223 V 17:05:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000368 Vs 17:05:39 Magnet Current for Main , Imag = 5.0072 A Vtrans = 0.417265 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:05:54 Voltage Offset Correction: v_off_ini = 0.000000134 V, v_off_fin = 0.000000045 V 17:05:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000312 Vs 17:06:08 Voltage Offset Correction: v_off_ini = 0.000000343 V, v_off_fin = 0.000000174 V 17:06:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000379 Vs 17:06:09 Magnet Current for Main , Imag = 5.0072 A Vtrans = 0.417264 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:06:24 Voltage Offset Correction: v_off_ini = 0.000000240 V, v_off_fin = 0.000000189 V 17:06:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000326 Vs 17:06:39 Voltage Offset Correction: v_off_ini = 0.000000360 V, v_off_fin = 0.000000370 V 17:06:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000364 Vs 17:06:39 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000359 +- 0.000000017 Vs 17:06:39 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000359 +- 0.000000017 Vs BL = 0.00035913 +- 0.00001740 Tm 17:06:46 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00036 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00036 0.00002 0.00036 0.00000 17:06:46 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00036 0.00002 SL = 0.0003591 +- 0.0000174 Tm^2/m^n 17:06:46 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0003591 +- 0.0000174 Tm^2/m^n 17:06:53 Magnet system Main current ramping to 6.0000 A... 17:07:06 Magnet Current for Main , Imag = 6.0081 A Vtrans = 0.500672 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:07:06 Magnet Voltage Measurement, V = 0.000000 V 17:07:07 Temperature Measurement, Probe Number = 0, T = 20.358000 C 17:07:07 Sensor Voltage Measurement, Sensor Number = 0, V = 1.664002 V 17:07:07 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.664002 (V, A, ohm, ...), Measured Value = 19.222251 (C, atm, Hz, ...) 17:07:08 Sensor Voltage Measurement, Sensor Number = 1, V = 1.683068 V 17:07:08 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.683068 (V, A, ohm, ...), Measured Value = 19.487056 (C, atm, Hz, ...) 17:07:08 Sensor Voltage Measurement, Sensor Number = 2, V = 1.006397 V 17:07:08 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.006397 (V, A, ohm, ...), Measured Value = 0.479767 (C, atm, Hz, ...) 17:07:09 Sensor Voltage Measurement, Sensor Number = 3, V = 1.002510 V 17:07:09 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002510 (V, A, ohm, ...), Measured Value = 0.188272 (C, atm, Hz, ...) 17:07:10 Sensor Voltage Measurement, Sensor Number = 4, V = 0.004318 V 17:07:10 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = 0.004318 (V, A, ohm, ...), Measured Value = 0.000733 (C, atm, Hz, ...) 17:07:10 Magnet Test Parameter Measurements P0 = Main , Value = 6.01 P1 = Magnet voltage (V), Value = 0.00 P2 = Ambient, Value = 20.36 P3 = Supply Temp(C), Value = 19.22 P4 = Return Temp(C), Value = 19.49 P5 = Supply Pres(psi), Value = 0.48 P6 = Return Pres(psi), Value = 0.19 P7 = Flow Rate(gpm), Value = 0.00 17:07:10 Magnetic Field Measurement Measuring the magnet strength... 17:07:10 Integrated Voltage Measurement... 17:07:10 Magnet Current for Main , Imag = 6.0081 A Vtrans = 0.500674 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:07:25 Voltage Offset Correction: v_off_ini = 0.000000300 V, v_off_fin = 0.000000249 V 17:07:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000421 Vs 17:07:40 Voltage Offset Correction: v_off_ini = 0.000000197 V, v_off_fin = 0.000000279 V 17:07:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000442 Vs 17:07:41 Magnet Current for Main , Imag = 6.0081 A Vtrans = 0.500673 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:07:56 Voltage Offset Correction: v_off_ini = 0.000000369 V, v_off_fin = 0.000000218 V 17:07:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000451 Vs 17:08:11 Voltage Offset Correction: v_off_ini = 0.000000194 V, v_off_fin = 0.000000197 V 17:08:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000437 Vs 17:08:11 Magnet Current for Main , Imag = 6.0080 A Vtrans = 0.500670 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:08:26 Voltage Offset Correction: v_off_ini = 0.000000218 V, v_off_fin = 0.000000224 V 17:08:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000418 Vs 17:08:41 Voltage Offset Correction: v_off_ini = 0.000000312 V, v_off_fin = 0.000000225 V 17:08:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000461 Vs 17:08:42 Magnet Current for Main , Imag = 6.0081 A Vtrans = 0.500673 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:08:57 Voltage Offset Correction: v_off_ini = 0.000000152 V, v_off_fin = 0.000000189 V 17:08:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000401 Vs 17:09:11 Voltage Offset Correction: v_off_ini = 0.000000169 V, v_off_fin = 0.000000391 V 17:09:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000427 Vs 17:09:12 Magnet Current for Main , Imag = 6.0081 A Vtrans = 0.500672 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:09:27 Voltage Offset Correction: v_off_ini = 0.000000326 V, v_off_fin = -0.000000245 V 17:09:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000418 Vs 17:09:42 Voltage Offset Correction: v_off_ini = 0.000000435 V, v_off_fin = 0.000000457 V 17:09:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000414 Vs 17:09:43 Magnet Current for Main , Imag = 6.0081 A Vtrans = 0.500671 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:09:57 Voltage Offset Correction: v_off_ini = 0.000000497 V, v_off_fin = 0.000000782 V 17:09:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000485 Vs 17:10:12 Voltage Offset Correction: v_off_ini = 0.000000298 V, v_off_fin = 0.000000388 V 17:10:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000446 Vs 17:10:13 Magnet Current for Main , Imag = 6.0081 A Vtrans = 0.500672 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:10:28 Voltage Offset Correction: v_off_ini = 0.000000479 V, v_off_fin = 0.000000606 V 17:10:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000442 Vs 17:10:43 Voltage Offset Correction: v_off_ini = 0.000000246 V, v_off_fin = 0.000000197 V 17:10:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000379 Vs 17:10:43 Magnet Current for Main , Imag = 6.0081 A Vtrans = 0.500672 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:10:58 Voltage Offset Correction: v_off_ini = 0.000000447 V, v_off_fin = 0.000000574 V 17:10:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000411 Vs 17:11:13 Voltage Offset Correction: v_off_ini = 0.000000209 V, v_off_fin = 0.000000237 V 17:11:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000404 Vs 17:11:14 Magnet Current for Main , Imag = 6.0081 A Vtrans = 0.500671 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:11:29 Voltage Offset Correction: v_off_ini = 0.000000321 V, v_off_fin = 0.000000314 V 17:11:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000441 Vs 17:11:44 Voltage Offset Correction: v_off_ini = 0.000000171 V, v_off_fin = 0.000000228 V 17:11:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000474 Vs 17:11:44 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000432 +- 0.000000020 Vs 17:11:44 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000432 +- 0.000000020 Vs BL = 0.00043181 +- 0.00001994 Tm 17:11:51 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00043 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00043 0.00002 0.00043 0.00000 17:11:51 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00043 0.00002 SL = 0.0004318 +- 0.0000199 Tm^2/m^n 17:11:51 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0004318 +- 0.0000199 Tm^2/m^n 17:11:58 Magnet system Main current ramping to 7.0000 A... 17:12:11 Magnet Current for Main , Imag = 7.0027 A Vtrans = 0.583556 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:12:11 Magnet Voltage Measurement, V = 0.000000 V 17:12:12 Temperature Measurement, Probe Number = 0, T = 20.347000 C 17:12:12 Sensor Voltage Measurement, Sensor Number = 0, V = 1.663273 V 17:12:12 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.663273 (V, A, ohm, ...), Measured Value = 19.212128 (C, atm, Hz, ...) 17:12:13 Sensor Voltage Measurement, Sensor Number = 1, V = 1.682765 V 17:12:13 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.682765 (V, A, ohm, ...), Measured Value = 19.482850 (C, atm, Hz, ...) 17:12:13 Sensor Voltage Measurement, Sensor Number = 2, V = 1.006430 V 17:12:13 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.006430 (V, A, ohm, ...), Measured Value = 0.482280 (C, atm, Hz, ...) 17:12:14 Sensor Voltage Measurement, Sensor Number = 3, V = 1.002463 V 17:12:14 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002463 (V, A, ohm, ...), Measured Value = 0.184755 (C, atm, Hz, ...) 17:12:14 Sensor Voltage Measurement, Sensor Number = 4, V = 0.004332 V 17:12:14 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = 0.004332 (V, A, ohm, ...), Measured Value = 0.000736 (C, atm, Hz, ...) 17:12:14 Magnet Test Parameter Measurements P0 = Main , Value = 7.00 P1 = Magnet voltage (V), Value = 0.00 P2 = Ambient, Value = 20.35 P3 = Supply Temp(C), Value = 19.21 P4 = Return Temp(C), Value = 19.48 P5 = Supply Pres(psi), Value = 0.48 P6 = Return Pres(psi), Value = 0.18 P7 = Flow Rate(gpm), Value = 0.00 17:12:14 Magnetic Field Measurement Measuring the magnet strength... 17:12:14 Integrated Voltage Measurement... 17:12:15 Magnet Current for Main , Imag = 7.0027 A Vtrans = 0.583559 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:12:30 Voltage Offset Correction: v_off_ini = 0.000000486 V, v_off_fin = 0.000000048 V 17:12:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000443 Vs 17:12:45 Voltage Offset Correction: v_off_ini = 0.000000427 V, v_off_fin = 0.000000460 V 17:12:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000537 Vs 17:12:46 Magnet Current for Main , Imag = 7.0027 A Vtrans = 0.583559 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:13:00 Voltage Offset Correction: v_off_ini = 0.000000328 V, v_off_fin = 0.000000314 V 17:13:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000495 Vs 17:13:15 Voltage Offset Correction: v_off_ini = 0.000000183 V, v_off_fin = 0.000000119 V 17:13:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000517 Vs 17:13:16 Magnet Current for Main , Imag = 7.0027 A Vtrans = 0.583557 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:13:31 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000448 V 17:13:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000505 Vs 17:13:46 Voltage Offset Correction: v_off_ini = 0.000000291 V, v_off_fin = -0.000000044 V 17:13:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000494 Vs 17:13:46 Magnet Current for Main , Imag = 7.0027 A Vtrans = 0.583557 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:14:01 Voltage Offset Correction: v_off_ini = 0.000000218 V, v_off_fin = 0.000000232 V 17:14:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000526 Vs 17:14:16 Voltage Offset Correction: v_off_ini = 0.000000423 V, v_off_fin = 0.000000538 V 17:14:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000496 Vs 17:14:17 Magnet Current for Main , Imag = 7.0027 A Vtrans = 0.583557 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:14:32 Voltage Offset Correction: v_off_ini = 0.000000314 V, v_off_fin = 0.000000279 V 17:14:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000462 Vs 17:14:47 Voltage Offset Correction: v_off_ini = 0.000000364 V, v_off_fin = 0.000000341 V 17:14:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000552 Vs 17:14:47 Magnet Current for Main , Imag = 7.0027 A Vtrans = 0.583557 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:15:02 Voltage Offset Correction: v_off_ini = 0.000000382 V, v_off_fin = 0.000000258 V 17:15:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000500 Vs 17:15:17 Voltage Offset Correction: v_off_ini = 0.000000338 V, v_off_fin = 0.000000108 V 17:15:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000473 Vs 17:15:18 Magnet Current for Main , Imag = 7.0027 A Vtrans = 0.583556 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:15:33 Voltage Offset Correction: v_off_ini = 0.000000345 V, v_off_fin = 0.000000438 V 17:15:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000459 Vs 17:15:47 Voltage Offset Correction: v_off_ini = 0.000000350 V, v_off_fin = 0.000000286 V 17:15:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000471 Vs 17:15:48 Magnet Current for Main , Imag = 7.0027 A Vtrans = 0.583556 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:16:03 Voltage Offset Correction: v_off_ini = 0.000000216 V, v_off_fin = 0.000000224 V 17:16:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000492 Vs 17:16:18 Voltage Offset Correction: v_off_ini = 0.000000240 V, v_off_fin = 0.000000161 V 17:16:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000461 Vs 17:16:18 Magnet Current for Main , Imag = 7.0027 A Vtrans = 0.583556 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:16:33 Voltage Offset Correction: v_off_ini = 0.000000353 V, v_off_fin = 0.000000114 V 17:16:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000490 Vs 17:16:48 Voltage Offset Correction: v_off_ini = 0.000000347 V, v_off_fin = 0.000000312 V 17:16:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000474 Vs 17:16:48 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000491 +- 0.000000015 Vs 17:16:48 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000491 +- 0.000000015 Vs BL = 0.00049149 +- 0.00001458 Tm 17:16:55 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00049 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00049 0.00001 0.00049 0.00000 17:16:55 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00049 0.00001 SL = 0.0004915 +- 0.0000146 Tm^2/m^n 17:16:55 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0004915 +- 0.0000146 Tm^2/m^n 17:17:02 Magnet system Main current ramping to 8.0000 A... 17:17:15 Magnet Current for Main , Imag = 8.0075 A Vtrans = 0.667289 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:17:15 Magnet Voltage Measurement, V = 0.000000 V 17:17:16 Temperature Measurement, Probe Number = 0, T = 20.346000 C 17:17:17 Sensor Voltage Measurement, Sensor Number = 0, V = 1.662325 V 17:17:17 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.662325 (V, A, ohm, ...), Measured Value = 19.198954 (C, atm, Hz, ...) 17:17:17 Sensor Voltage Measurement, Sensor Number = 1, V = 1.682477 V 17:17:17 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.682477 (V, A, ohm, ...), Measured Value = 19.478849 (C, atm, Hz, ...) 17:17:18 Sensor Voltage Measurement, Sensor Number = 2, V = 1.006236 V 17:17:18 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.006236 (V, A, ohm, ...), Measured Value = 0.467707 (C, atm, Hz, ...) 17:17:18 Sensor Voltage Measurement, Sensor Number = 3, V = 1.002528 V 17:17:18 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002528 (V, A, ohm, ...), Measured Value = 0.189577 (C, atm, Hz, ...) 17:17:19 Sensor Voltage Measurement, Sensor Number = 4, V = 0.005404 V 17:17:19 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = 0.005404 (V, A, ohm, ...), Measured Value = 0.000918 (C, atm, Hz, ...) 17:17:19 Magnet Test Parameter Measurements P0 = Main , Value = 8.01 P1 = Magnet voltage (V), Value = 0.00 P2 = Ambient, Value = 20.35 P3 = Supply Temp(C), Value = 19.20 P4 = Return Temp(C), Value = 19.48 P5 = Supply Pres(psi), Value = 0.47 P6 = Return Pres(psi), Value = 0.19 P7 = Flow Rate(gpm), Value = 0.00 17:17:19 Magnetic Field Measurement Measuring the magnet strength... 17:17:19 Integrated Voltage Measurement... 17:17:20 Magnet Current for Main , Imag = 8.0075 A Vtrans = 0.667289 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:17:35 Voltage Offset Correction: v_off_ini = 0.000000054 V, v_off_fin = 0.000000154 V 17:17:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000553 Vs 17:17:49 Voltage Offset Correction: v_off_ini = 0.000000377 V, v_off_fin = 0.000000312 V 17:17:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000568 Vs 17:17:50 Magnet Current for Main , Imag = 8.0075 A Vtrans = 0.667288 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:18:05 Voltage Offset Correction: v_off_ini = 0.000000334 V, v_off_fin = 0.000000336 V 17:18:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000568 Vs 17:18:20 Voltage Offset Correction: v_off_ini = 0.000000341 V, v_off_fin = 0.000000447 V 17:18:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000525 Vs 17:18:21 Magnet Current for Main , Imag = 8.0075 A Vtrans = 0.667288 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:18:35 Voltage Offset Correction: v_off_ini = 0.000000324 V, v_off_fin = 0.000000283 V 17:18:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000529 Vs 17:18:50 Voltage Offset Correction: v_off_ini = 0.000000285 V, v_off_fin = 0.000000420 V 17:18:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000577 Vs 17:18:51 Magnet Current for Main , Imag = 8.0075 A Vtrans = 0.667288 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:19:06 Voltage Offset Correction: v_off_ini = 0.000000371 V, v_off_fin = 0.000000326 V 17:19:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000524 Vs 17:19:21 Voltage Offset Correction: v_off_ini = 0.000000520 V, v_off_fin = 0.000000595 V 17:19:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000557 Vs 17:19:21 Magnet Current for Main , Imag = 8.0075 A Vtrans = 0.667289 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:19:36 Voltage Offset Correction: v_off_ini = 0.000000546 V, v_off_fin = 0.000000249 V 17:19:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000496 Vs 17:19:51 Voltage Offset Correction: v_off_ini = 0.000000228 V, v_off_fin = 0.000000465 V 17:19:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000583 Vs 17:19:52 Magnet Current for Main , Imag = 8.0075 A Vtrans = 0.667290 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:20:07 Voltage Offset Correction: v_off_ini = 0.000000422 V, v_off_fin = 0.000000346 V 17:20:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000571 Vs 17:20:22 Voltage Offset Correction: v_off_ini = 0.000000530 V, v_off_fin = 0.000000609 V 17:20:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000540 Vs 17:20:22 Magnet Current for Main , Imag = 8.0075 A Vtrans = 0.667288 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:20:37 Voltage Offset Correction: v_off_ini = 0.000000372 V, v_off_fin = 0.000000235 V 17:20:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000599 Vs 17:20:52 Voltage Offset Correction: v_off_ini = 0.000000341 V, v_off_fin = 0.000000616 V 17:20:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000521 Vs 17:20:53 Magnet Current for Main , Imag = 8.0075 A Vtrans = 0.667288 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:21:08 Voltage Offset Correction: v_off_ini = 0.000000447 V, v_off_fin = 0.000000566 V 17:21:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000567 Vs 17:21:22 Voltage Offset Correction: v_off_ini = 0.000000311 V, v_off_fin = 0.000000303 V 17:21:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000597 Vs 17:21:23 Magnet Current for Main , Imag = 8.0074 A Vtrans = 0.667287 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:21:38 Voltage Offset Correction: v_off_ini = 0.000000322 V, v_off_fin = 0.000000075 V 17:21:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000549 Vs 17:21:53 Voltage Offset Correction: v_off_ini = 0.000000253 V, v_off_fin = 0.000000319 V 17:21:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000505 Vs 17:21:53 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000552 +- 0.000000015 Vs 17:21:53 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000552 +- 0.000000015 Vs BL = 0.00055167 +- 0.00001487 Tm 17:22:00 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00055 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00055 0.00001 0.00055 0.00000 17:22:00 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00055 0.00001 SL = 0.0005517 +- 0.0000149 Tm^2/m^n 17:22:00 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0005517 +- 0.0000149 Tm^2/m^n 17:22:07 Magnet system Main current ramping to 9.0000 A... 17:22:20 Magnet Current for Main , Imag = 9.0074 A Vtrans = 0.750619 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:22:20 Magnet Voltage Measurement, V = 0.000000 V 17:22:21 Temperature Measurement, Probe Number = 0, T = 20.361000 C 17:22:21 Sensor Voltage Measurement, Sensor Number = 0, V = 1.661333 V 17:22:21 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.661333 (V, A, ohm, ...), Measured Value = 19.185185 (C, atm, Hz, ...) 17:22:22 Sensor Voltage Measurement, Sensor Number = 1, V = 1.681893 V 17:22:22 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.681893 (V, A, ohm, ...), Measured Value = 19.470736 (C, atm, Hz, ...) 17:22:23 Sensor Voltage Measurement, Sensor Number = 2, V = 1.006260 V 17:22:23 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.006260 (V, A, ohm, ...), Measured Value = 0.469515 (C, atm, Hz, ...) 17:22:23 Sensor Voltage Measurement, Sensor Number = 3, V = 1.002640 V 17:22:23 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002640 (V, A, ohm, ...), Measured Value = 0.198015 (C, atm, Hz, ...) 17:22:24 Sensor Voltage Measurement, Sensor Number = 4, V = 0.004327 V 17:22:24 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = 0.004327 (V, A, ohm, ...), Measured Value = 0.000735 (C, atm, Hz, ...) 17:22:24 Magnet Test Parameter Measurements P0 = Main , Value = 9.01 P1 = Magnet voltage (V), Value = 0.00 P2 = Ambient, Value = 20.36 P3 = Supply Temp(C), Value = 19.19 P4 = Return Temp(C), Value = 19.47 P5 = Supply Pres(psi), Value = 0.47 P6 = Return Pres(psi), Value = 0.20 P7 = Flow Rate(gpm), Value = 0.00 17:22:24 Magnetic Field Measurement Measuring the magnet strength... 17:22:24 Integrated Voltage Measurement... 17:22:24 Magnet Current for Main , Imag = 9.0074 A Vtrans = 0.750620 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:22:39 Voltage Offset Correction: v_off_ini = 0.000000453 V, v_off_fin = 0.000000017 V 17:22:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000589 Vs 17:22:54 Voltage Offset Correction: v_off_ini = 0.000000254 V, v_off_fin = 0.000000345 V 17:22:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000597 Vs 17:22:55 Magnet Current for Main , Imag = 9.0074 A Vtrans = 0.750620 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:23:10 Voltage Offset Correction: v_off_ini = 0.000000461 V, v_off_fin = 0.000000709 V 17:23:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000648 Vs 17:23:25 Voltage Offset Correction: v_off_ini = 0.000000267 V, v_off_fin = 0.000000442 V 17:23:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000609 Vs 17:23:25 Magnet Current for Main , Imag = 9.0074 A Vtrans = 0.750621 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:23:40 Voltage Offset Correction: v_off_ini = 0.000000298 V, v_off_fin = 0.000000264 V 17:23:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000613 Vs 17:23:55 Voltage Offset Correction: v_off_ini = 0.000000419 V, v_off_fin = 0.000000631 V 17:23:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000642 Vs 17:23:56 Magnet Current for Main , Imag = 9.0074 A Vtrans = 0.750621 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:24:11 Voltage Offset Correction: v_off_ini = 0.000000401 V, v_off_fin = 0.000000558 V 17:24:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000601 Vs 17:24:25 Voltage Offset Correction: v_off_ini = 0.000000721 V, v_off_fin = 0.000000648 V 17:24:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000568 Vs 17:24:26 Magnet Current for Main , Imag = 9.0075 A Vtrans = 0.750621 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:24:41 Voltage Offset Correction: v_off_ini = 0.000000241 V, v_off_fin = 0.000000203 V 17:24:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000615 Vs 17:24:56 Voltage Offset Correction: v_off_ini = 0.000000404 V, v_off_fin = 0.000000215 V 17:24:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000611 Vs 17:24:57 Magnet Current for Main , Imag = 9.0075 A Vtrans = 0.750622 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:25:11 Voltage Offset Correction: v_off_ini = 0.000000487 V, v_off_fin = 0.000000007 V 17:25:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000649 Vs 17:25:26 Voltage Offset Correction: v_off_ini = 0.000000355 V, v_off_fin = 0.000000505 V 17:25:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000591 Vs 17:25:27 Magnet Current for Main , Imag = 9.0075 A Vtrans = 0.750622 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:25:42 Voltage Offset Correction: v_off_ini = 0.000000389 V, v_off_fin = 0.000000258 V 17:25:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000622 Vs 17:25:57 Voltage Offset Correction: v_off_ini = 0.000000482 V, v_off_fin = 0.000000443 V 17:25:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000634 Vs 17:25:57 Magnet Current for Main , Imag = 9.0075 A Vtrans = 0.750622 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:26:12 Voltage Offset Correction: v_off_ini = 0.000000367 V, v_off_fin = 0.000000369 V 17:26:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000620 Vs 17:26:27 Voltage Offset Correction: v_off_ini = 0.000000733 V, v_off_fin = 0.000000566 V 17:26:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000628 Vs 17:26:28 Magnet Current for Main , Imag = 9.0075 A Vtrans = 0.750623 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:26:43 Voltage Offset Correction: v_off_ini = 0.000000398 V, v_off_fin = 0.000000235 V 17:26:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000632 Vs 17:26:58 Voltage Offset Correction: v_off_ini = 0.000000310 V, v_off_fin = 0.000000395 V 17:26:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000573 Vs 17:26:58 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000613 +- 0.000000016 Vs 17:26:58 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000613 +- 0.000000016 Vs BL = 0.00061345 +- 0.00001558 Tm 17:27:05 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00061 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00061 0.00002 0.00061 0.00000 17:27:05 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00061 0.00002 SL = 0.0006135 +- 0.0000156 Tm^2/m^n 17:27:05 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0006135 +- 0.0000156 Tm^2/m^n 17:27:12 Magnet system Main current ramping to 10.0000 A... 17:27:25 Magnet Current for Main , Imag = 10.0087 A Vtrans = 0.834055 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:27:25 Magnet Voltage Measurement, V = 0.000000 V 17:27:26 Temperature Measurement, Probe Number = 0, T = 20.366000 C 17:27:26 Sensor Voltage Measurement, Sensor Number = 0, V = 1.660287 V 17:27:26 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.660287 (V, A, ohm, ...), Measured Value = 19.170653 (C, atm, Hz, ...) 17:27:27 Sensor Voltage Measurement, Sensor Number = 1, V = 1.681439 V 17:27:27 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.681439 (V, A, ohm, ...), Measured Value = 19.464428 (C, atm, Hz, ...) 17:27:27 Sensor Voltage Measurement, Sensor Number = 2, V = 1.006392 V 17:27:27 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.006392 (V, A, ohm, ...), Measured Value = 0.479363 (C, atm, Hz, ...) 17:27:28 Sensor Voltage Measurement, Sensor Number = 3, V = 1.002534 V 17:27:28 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002534 (V, A, ohm, ...), Measured Value = 0.190080 (C, atm, Hz, ...) 17:27:28 Sensor Voltage Measurement, Sensor Number = 4, V = 0.004323 V 17:27:28 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = 0.004323 (V, A, ohm, ...), Measured Value = 0.000734 (C, atm, Hz, ...) 17:27:28 Magnet Test Parameter Measurements P0 = Main , Value = 10.01 P1 = Magnet voltage (V), Value = 0.00 P2 = Ambient, Value = 20.37 P3 = Supply Temp(C), Value = 19.17 P4 = Return Temp(C), Value = 19.46 P5 = Supply Pres(psi), Value = 0.48 P6 = Return Pres(psi), Value = 0.19 P7 = Flow Rate(gpm), Value = 0.00 17:27:28 Magnetic Field Measurement Measuring the magnet strength... 17:27:28 Integrated Voltage Measurement... 17:27:29 Magnet Current for Main , Imag = 10.0087 A Vtrans = 0.834055 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:27:44 Voltage Offset Correction: v_off_ini = 0.000000374 V, v_off_fin = 0.000000263 V 17:27:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000666 Vs 17:27:59 Voltage Offset Correction: v_off_ini = 0.000000510 V, v_off_fin = 0.000000388 V 17:27:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000693 Vs 17:28:00 Magnet Current for Main , Imag = 10.0087 A Vtrans = 0.834055 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:28:14 Voltage Offset Correction: v_off_ini = 0.000000491 V, v_off_fin = 0.000001134 V 17:28:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000656 Vs 17:28:29 Voltage Offset Correction: v_off_ini = 0.000000411 V, v_off_fin = 0.000000194 V 17:28:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000578 Vs 17:28:30 Magnet Current for Main , Imag = 10.0087 A Vtrans = 0.834058 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:28:45 Voltage Offset Correction: v_off_ini = 0.000000373 V, v_off_fin = 0.000000417 V 17:28:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000687 Vs 17:29:00 Voltage Offset Correction: v_off_ini = 0.000000476 V, v_off_fin = 0.000000300 V 17:29:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000647 Vs 17:29:00 Magnet Current for Main , Imag = 10.0087 A Vtrans = 0.834061 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:29:15 Voltage Offset Correction: v_off_ini = 0.000000336 V, v_off_fin = 0.000000386 V 17:29:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000730 Vs 17:29:30 Voltage Offset Correction: v_off_ini = 0.000000495 V, v_off_fin = 0.000000162 V 17:29:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000698 Vs 17:29:31 Magnet Current for Main , Imag = 10.0087 A Vtrans = 0.834060 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:29:46 Voltage Offset Correction: v_off_ini = 0.000000462 V, v_off_fin = 0.000000737 V 17:29:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000660 Vs 17:30:01 Voltage Offset Correction: v_off_ini = 0.000000359 V, v_off_fin = 0.000000369 V 17:30:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000672 Vs 17:30:01 Magnet Current for Main , Imag = 10.0087 A Vtrans = 0.834061 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:30:16 Voltage Offset Correction: v_off_ini = 0.000000528 V, v_off_fin = 0.000000238 V 17:30:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000672 Vs 17:30:31 Voltage Offset Correction: v_off_ini = 0.000000281 V, v_off_fin = 0.000000200 V 17:30:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000634 Vs 17:30:32 Magnet Current for Main , Imag = 10.0087 A Vtrans = 0.834060 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:30:47 Voltage Offset Correction: v_off_ini = 0.000000556 V, v_off_fin = 0.000000640 V 17:30:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000776 Vs 17:31:01 Voltage Offset Correction: v_off_ini = 0.000000271 V, v_off_fin = 0.000000484 V 17:31:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000706 Vs 17:31:02 Magnet Current for Main , Imag = 10.0087 A Vtrans = 0.834062 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:31:17 Voltage Offset Correction: v_off_ini = 0.000000343 V, v_off_fin = 0.000000262 V 17:31:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000697 Vs 17:31:32 Voltage Offset Correction: v_off_ini = 0.000000444 V, v_off_fin = 0.000000572 V 17:31:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000683 Vs 17:31:33 Magnet Current for Main , Imag = 10.0087 A Vtrans = 0.834062 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:31:47 Voltage Offset Correction: v_off_ini = 0.000000331 V, v_off_fin = 0.000000069 V 17:31:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000678 Vs 17:32:02 Voltage Offset Correction: v_off_ini = 0.000000458 V, v_off_fin = 0.000000544 V 17:32:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000675 Vs 17:32:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000678 +- 0.000000033 Vs 17:32:02 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000678 +- 0.000000033 Vs BL = 0.00067826 +- 0.00003328 Tm 17:32:09 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00068 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00068 0.00003 0.00068 0.00000 17:32:09 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00068 0.00003 SL = 0.0006783 +- 0.0000333 Tm^2/m^n 17:32:09 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0006783 +- 0.0000333 Tm^2/m^n 17:32:17 Magnet system Main current ramping to 11.0000 A... 17:32:30 Magnet Current for Main , Imag = 11.0087 A Vtrans = 0.917388 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:32:30 Magnet Voltage Measurement, V = 0.000000 V 17:32:30 Temperature Measurement, Probe Number = 0, T = 20.363000 C 17:32:31 Sensor Voltage Measurement, Sensor Number = 0, V = 1.659317 V 17:32:31 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.659317 (V, A, ohm, ...), Measured Value = 19.157181 (C, atm, Hz, ...) 17:32:31 Sensor Voltage Measurement, Sensor Number = 1, V = 1.680965 V 17:32:31 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.680965 (V, A, ohm, ...), Measured Value = 19.457842 (C, atm, Hz, ...) 17:32:32 Sensor Voltage Measurement, Sensor Number = 2, V = 1.006347 V 17:32:32 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.006347 (V, A, ohm, ...), Measured Value = 0.476048 (C, atm, Hz, ...) 17:32:33 Sensor Voltage Measurement, Sensor Number = 3, V = 1.002609 V 17:32:33 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002609 (V, A, ohm, ...), Measured Value = 0.195705 (C, atm, Hz, ...) 17:32:33 Sensor Voltage Measurement, Sensor Number = 4, V = 0.004329 V 17:32:33 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = 0.004329 (V, A, ohm, ...), Measured Value = 0.000735 (C, atm, Hz, ...) 17:32:33 Magnet Test Parameter Measurements P0 = Main , Value = 11.01 P1 = Magnet voltage (V), Value = 0.00 P2 = Ambient, Value = 20.36 P3 = Supply Temp(C), Value = 19.16 P4 = Return Temp(C), Value = 19.46 P5 = Supply Pres(psi), Value = 0.48 P6 = Return Pres(psi), Value = 0.20 P7 = Flow Rate(gpm), Value = 0.00 17:32:33 Magnetic Field Measurement Measuring the magnet strength... 17:32:33 Integrated Voltage Measurement... 17:32:34 Magnet Current for Main , Imag = 11.0087 A Vtrans = 0.917390 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:32:49 Voltage Offset Correction: v_off_ini = 0.000000249 V, v_off_fin = 0.000000012 V 17:32:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000683 Vs 17:33:04 Voltage Offset Correction: v_off_ini = 0.000000303 V, v_off_fin = 0.000000132 V 17:33:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000748 Vs 17:33:04 Magnet Current for Main , Imag = 11.0087 A Vtrans = 0.917393 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:33:19 Voltage Offset Correction: v_off_ini = 0.000000381 V, v_off_fin = 0.000000402 V 17:33:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000702 Vs 17:33:34 Voltage Offset Correction: v_off_ini = 0.000000376 V, v_off_fin = 0.000000586 V 17:33:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000699 Vs 17:33:35 Magnet Current for Main , Imag = 11.0088 A Vtrans = 0.917396 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:33:50 Voltage Offset Correction: v_off_ini = 0.000000312 V, v_off_fin = 0.000000339 V 17:33:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000727 Vs 17:34:04 Voltage Offset Correction: v_off_ini = 0.000000453 V, v_off_fin = 0.000000440 V 17:34:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000822 Vs 17:34:05 Magnet Current for Main , Imag = 11.0088 A Vtrans = 0.917398 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:34:20 Voltage Offset Correction: v_off_ini = 0.000000228 V, v_off_fin = 0.000000295 V 17:34:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000715 Vs 17:34:35 Voltage Offset Correction: v_off_ini = 0.000000146 V, v_off_fin = 0.000000354 V 17:34:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000750 Vs 17:34:36 Magnet Current for Main , Imag = 11.0088 A Vtrans = 0.917399 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:34:50 Voltage Offset Correction: v_off_ini = 0.000000497 V, v_off_fin = 0.000000299 V 17:34:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000701 Vs 17:35:05 Voltage Offset Correction: v_off_ini = 0.000000297 V, v_off_fin = 0.000000432 V 17:35:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000750 Vs 17:35:06 Magnet Current for Main , Imag = 11.0088 A Vtrans = 0.917401 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:35:21 Voltage Offset Correction: v_off_ini = 0.000000282 V, v_off_fin = 0.000000164 V 17:35:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000674 Vs 17:35:36 Voltage Offset Correction: v_off_ini = 0.000000437 V, v_off_fin = 0.000000486 V 17:35:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000771 Vs 17:35:36 Magnet Current for Main , Imag = 11.0088 A Vtrans = 0.917403 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:35:51 Voltage Offset Correction: v_off_ini = 0.000000512 V, v_off_fin = 0.000000353 V 17:35:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000702 Vs 17:36:06 Voltage Offset Correction: v_off_ini = 0.000000410 V, v_off_fin = 0.000000469 V 17:36:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000741 Vs 17:36:07 Magnet Current for Main , Imag = 11.0088 A Vtrans = 0.917403 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:36:22 Voltage Offset Correction: v_off_ini = 0.000000486 V, v_off_fin = 0.000000647 V 17:36:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000680 Vs 17:36:37 Voltage Offset Correction: v_off_ini = 0.000000342 V, v_off_fin = 0.000000374 V 17:36:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000753 Vs 17:36:37 Magnet Current for Main , Imag = 11.0089 A Vtrans = 0.917405 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:36:52 Voltage Offset Correction: v_off_ini = 0.000000533 V, v_off_fin = 0.000000515 V 17:36:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000761 Vs 17:37:07 Voltage Offset Correction: v_off_ini = 0.000000435 V, v_off_fin = 0.000000531 V 17:37:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000743 Vs 17:37:07 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000729 +- 0.000000021 Vs 17:37:07 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000729 +- 0.000000021 Vs BL = 0.00072905 +- 0.00002075 Tm 17:37:14 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00073 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00073 0.00002 0.00073 0.00000 17:37:14 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00073 0.00002 SL = 0.0007291 +- 0.0000208 Tm^2/m^n 17:37:14 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0007291 +- 0.0000208 Tm^2/m^n 17:37:21 Magnet system Main current ramping to 12.0000 A... 17:37:34 Magnet Current for Main , Imag = 12.0092 A Vtrans = 1.000763 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:37:34 Magnet Voltage Measurement, V = 0.000000 V 17:37:35 Temperature Measurement, Probe Number = 0, T = 20.397000 C 17:37:35 Sensor Voltage Measurement, Sensor Number = 0, V = 1.658312 V 17:37:35 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.658312 (V, A, ohm, ...), Measured Value = 19.143225 (C, atm, Hz, ...) 17:37:36 Sensor Voltage Measurement, Sensor Number = 1, V = 1.680488 V 17:37:36 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.680488 (V, A, ohm, ...), Measured Value = 19.451217 (C, atm, Hz, ...) 17:37:37 Sensor Voltage Measurement, Sensor Number = 2, V = 1.006263 V 17:37:37 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.006263 (V, A, ohm, ...), Measured Value = 0.469718 (C, atm, Hz, ...) 17:37:37 Sensor Voltage Measurement, Sensor Number = 3, V = 1.002466 V 17:37:37 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002466 (V, A, ohm, ...), Measured Value = 0.184957 (C, atm, Hz, ...) 17:37:38 Sensor Voltage Measurement, Sensor Number = 4, V = 0.012382 V 17:37:38 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = 0.012382 (V, A, ohm, ...), Measured Value = 0.002103 (C, atm, Hz, ...) 17:37:38 Magnet Test Parameter Measurements P0 = Main , Value = 12.01 P1 = Magnet voltage (V), Value = 0.00 P2 = Ambient, Value = 20.40 P3 = Supply Temp(C), Value = 19.14 P4 = Return Temp(C), Value = 19.45 P5 = Supply Pres(psi), Value = 0.47 P6 = Return Pres(psi), Value = 0.18 P7 = Flow Rate(gpm), Value = 0.00 17:37:38 Magnetic Field Measurement Measuring the magnet strength... 17:37:38 Integrated Voltage Measurement... 17:37:39 Magnet Current for Main , Imag = 12.0092 A Vtrans = 1.000766 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:37:53 Voltage Offset Correction: v_off_ini = 0.000000391 V, v_off_fin = 0.000000353 V 17:37:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000809 Vs 17:38:08 Voltage Offset Correction: v_off_ini = 0.000000307 V, v_off_fin = 0.000000249 V 17:38:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000766 Vs 17:38:09 Magnet Current for Main , Imag = 12.0093 A Vtrans = 1.000772 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:38:24 Voltage Offset Correction: v_off_ini = 0.000000342 V, v_off_fin = 0.000000017 V 17:38:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000830 Vs 17:38:39 Voltage Offset Correction: v_off_ini = 0.000000217 V, v_off_fin = 0.000000566 V 17:38:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000815 Vs 17:38:39 Magnet Current for Main , Imag = 12.0093 A Vtrans = 1.000775 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:38:54 Voltage Offset Correction: v_off_ini = 0.000000573 V, v_off_fin = 0.000000409 V 17:38:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000774 Vs 17:39:09 Voltage Offset Correction: v_off_ini = 0.000000416 V, v_off_fin = 0.000000287 V 17:39:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000789 Vs 17:39:10 Magnet Current for Main , Imag = 12.0094 A Vtrans = 1.000780 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:39:25 Voltage Offset Correction: v_off_ini = 0.000000457 V, v_off_fin = 0.000000518 V 17:39:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000796 Vs 17:39:40 Voltage Offset Correction: v_off_ini = 0.000000393 V, v_off_fin = 0.000000351 V 17:39:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000827 Vs 17:39:40 Magnet Current for Main , Imag = 12.0094 A Vtrans = 1.000785 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:39:55 Voltage Offset Correction: v_off_ini = 0.000000319 V, v_off_fin = 0.000000103 V 17:39:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000858 Vs 17:40:10 Voltage Offset Correction: v_off_ini = 0.000000407 V, v_off_fin = 0.000000271 V 17:40:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000780 Vs 17:40:11 Magnet Current for Main , Imag = 12.0094 A Vtrans = 1.000786 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:40:26 Voltage Offset Correction: v_off_ini = 0.000000264 V, v_off_fin = 0.000000039 V 17:40:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000835 Vs 17:40:41 Voltage Offset Correction: v_off_ini = 0.000000370 V, v_off_fin = 0.000000751 V 17:40:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000792 Vs 17:40:41 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000788 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:40:56 Voltage Offset Correction: v_off_ini = 0.000000261 V, v_off_fin = 0.000000333 V 17:40:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000787 Vs 17:41:11 Voltage Offset Correction: v_off_ini = 0.000000221 V, v_off_fin = 0.000000094 V 17:41:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000836 Vs 17:41:12 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000791 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:41:27 Voltage Offset Correction: v_off_ini = 0.000000294 V, v_off_fin = 0.000000445 V 17:41:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000791 Vs 17:41:41 Voltage Offset Correction: v_off_ini = 0.000000136 V, v_off_fin = 0.000000273 V 17:41:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000837 Vs 17:41:42 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000791 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:41:57 Voltage Offset Correction: v_off_ini = 0.000000136 V, v_off_fin = 0.000000115 V 17:41:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000785 Vs 17:42:12 Voltage Offset Correction: v_off_ini = 0.000000397 V, v_off_fin = 0.000000166 V 17:42:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000802 Vs 17:42:12 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000806 +- 0.000000014 Vs 17:42:12 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000806 +- 0.000000014 Vs BL = 0.00080613 +- 0.00001375 Tm 17:42:19 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00081 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00081 0.00001 0.00081 0.00000 17:42:19 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00081 0.00001 SL = 0.0008061 +- 0.0000137 Tm^2/m^n 17:42:19 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0008061 +- 0.0000137 Tm^2/m^n 17:42:26 Magnet system Main current ramping to 12.0000 A... 17:42:37 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000793 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:42:37 Magnet Voltage Measurement, V = 0.000000 V 17:42:38 Temperature Measurement, Probe Number = 0, T = 20.400000 C 17:42:38 Sensor Voltage Measurement, Sensor Number = 0, V = 1.657266 V 17:42:38 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.657266 (V, A, ohm, ...), Measured Value = 19.128692 (C, atm, Hz, ...) 17:42:39 Sensor Voltage Measurement, Sensor Number = 1, V = 1.679877 V 17:42:39 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.679877 (V, A, ohm, ...), Measured Value = 19.442732 (C, atm, Hz, ...) 17:42:40 Sensor Voltage Measurement, Sensor Number = 2, V = 1.006298 V 17:42:40 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.006298 (V, A, ohm, ...), Measured Value = 0.472327 (C, atm, Hz, ...) 17:42:40 Sensor Voltage Measurement, Sensor Number = 3, V = 1.002504 V 17:42:40 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002504 (V, A, ohm, ...), Measured Value = 0.187770 (C, atm, Hz, ...) 17:42:41 Sensor Voltage Measurement, Sensor Number = 4, V = 0.004270 V 17:42:41 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = 0.004270 (V, A, ohm, ...), Measured Value = 0.000725 (C, atm, Hz, ...) 17:42:41 Magnet Test Parameter Measurements P0 = Main , Value = 12.01 P1 = Magnet voltage (V), Value = 0.00 P2 = Ambient, Value = 20.40 P3 = Supply Temp(C), Value = 19.13 P4 = Return Temp(C), Value = 19.44 P5 = Supply Pres(psi), Value = 0.47 P6 = Return Pres(psi), Value = 0.19 P7 = Flow Rate(gpm), Value = 0.00 17:42:41 Magnetic Field Measurement Measuring the magnet strength... 17:42:41 Integrated Voltage Measurement... 17:42:41 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000793 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:42:56 Voltage Offset Correction: v_off_ini = 0.000000281 V, v_off_fin = 0.000000335 V 17:42:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000823 Vs 17:43:11 Voltage Offset Correction: v_off_ini = 0.000000226 V, v_off_fin = 0.000000255 V 17:43:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000827 Vs 17:43:12 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:43:27 Voltage Offset Correction: v_off_ini = 0.000000235 V, v_off_fin = 0.000000207 V 17:43:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000816 Vs 17:43:42 Voltage Offset Correction: v_off_ini = 0.000000253 V, v_off_fin = 0.000000539 V 17:43:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000847 Vs 17:43:42 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000794 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:43:57 Voltage Offset Correction: v_off_ini = 0.000000130 V, v_off_fin = -0.000000141 V 17:43:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000831 Vs 17:44:12 Voltage Offset Correction: v_off_ini = 0.000000281 V, v_off_fin = 0.000000250 V 17:44:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000816 Vs 17:44:13 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000794 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:44:28 Voltage Offset Correction: v_off_ini = 0.000000407 V, v_off_fin = 0.000000376 V 17:44:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000770 Vs 17:44:42 Voltage Offset Correction: v_off_ini = 0.000000200 V, v_off_fin = 0.000000701 V 17:44:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000916 Vs 17:44:43 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:44:58 Voltage Offset Correction: v_off_ini = 0.000000121 V, v_off_fin = 0.000000058 V 17:44:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000865 Vs 17:45:13 Voltage Offset Correction: v_off_ini = 0.000000134 V, v_off_fin = 0.000000384 V 17:45:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000897 Vs 17:45:14 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:45:28 Voltage Offset Correction: v_off_ini = 0.000000245 V, v_off_fin = 0.000000476 V 17:45:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000797 Vs 17:45:43 Voltage Offset Correction: v_off_ini = 0.000000212 V, v_off_fin = 0.000000127 V 17:45:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000826 Vs 17:45:44 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:45:59 Voltage Offset Correction: v_off_ini = 0.000000195 V, v_off_fin = 0.000000172 V 17:45:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000825 Vs 17:46:14 Voltage Offset Correction: v_off_ini = 0.000000261 V, v_off_fin = 0.000000219 V 17:46:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000780 Vs 17:46:14 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:46:29 Voltage Offset Correction: v_off_ini = 0.000000374 V, v_off_fin = 0.000000440 V 17:46:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000763 Vs 17:46:44 Voltage Offset Correction: v_off_ini = 0.000000206 V, v_off_fin = 0.000000126 V 17:46:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000783 Vs 17:46:45 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000794 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:47:00 Voltage Offset Correction: v_off_ini = 0.000000141 V, v_off_fin = -0.000000258 V 17:47:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000868 Vs 17:47:14 Voltage Offset Correction: v_off_ini = 0.000000326 V, v_off_fin = 0.000000238 V 17:47:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000827 Vs 17:47:14 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000826 +- 0.000000029 Vs 17:47:14 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000826 +- 0.000000029 Vs BL = 0.00082642 +- 0.00002867 Tm 17:47:22 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00083 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00083 0.00003 0.00083 0.00000 17:47:22 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00083 0.00003 SL = 0.0008264 +- 0.0000287 Tm^2/m^n 17:47:22 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0008264 +- 0.0000287 Tm^2/m^n 17:47:29 Magnet system Main current ramping to 12.0000 A... 17:47:40 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:47:40 Magnet Voltage Measurement, V = 0.000000 V 17:47:40 Temperature Measurement, Probe Number = 0, T = 20.370000 C 17:47:41 Sensor Voltage Measurement, Sensor Number = 0, V = 1.656312 V 17:47:41 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.656312 (V, A, ohm, ...), Measured Value = 19.115443 (C, atm, Hz, ...) 17:47:42 Sensor Voltage Measurement, Sensor Number = 1, V = 1.679291 V 17:47:42 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.679291 (V, A, ohm, ...), Measured Value = 19.434600 (C, atm, Hz, ...) 17:47:42 Sensor Voltage Measurement, Sensor Number = 2, V = 1.006137 V 17:47:42 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.006137 (V, A, ohm, ...), Measured Value = 0.460275 (C, atm, Hz, ...) 17:47:43 Sensor Voltage Measurement, Sensor Number = 3, V = 1.002475 V 17:47:43 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002475 (V, A, ohm, ...), Measured Value = 0.185655 (C, atm, Hz, ...) 17:47:43 Sensor Voltage Measurement, Sensor Number = 4, V = 0.004332 V 17:47:43 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = 0.004332 (V, A, ohm, ...), Measured Value = 0.000736 (C, atm, Hz, ...) 17:47:43 Magnet Test Parameter Measurements P0 = Main , Value = 12.01 P1 = Magnet voltage (V), Value = 0.00 P2 = Ambient, Value = 20.37 P3 = Supply Temp(C), Value = 19.12 P4 = Return Temp(C), Value = 19.43 P5 = Supply Pres(psi), Value = 0.46 P6 = Return Pres(psi), Value = 0.19 P7 = Flow Rate(gpm), Value = 0.00 17:47:43 Magnetic Field Measurement Measuring the magnet strength... 17:47:43 Integrated Voltage Measurement... 17:47:44 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:47:59 Voltage Offset Correction: v_off_ini = 0.000000328 V, v_off_fin = 0.000000266 V 17:47:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000834 Vs 17:48:14 Voltage Offset Correction: v_off_ini = 0.000000250 V, v_off_fin = 0.000000178 V 17:48:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000824 Vs 17:48:14 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:48:29 Voltage Offset Correction: v_off_ini = 0.000000295 V, v_off_fin = 0.000000465 V 17:48:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000765 Vs 17:48:44 Voltage Offset Correction: v_off_ini = 0.000000372 V, v_off_fin = 0.000000497 V 17:48:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000790 Vs 17:48:45 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:49:00 Voltage Offset Correction: v_off_ini = 0.000000197 V, v_off_fin = 0.000000328 V 17:49:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000861 Vs 17:49:15 Voltage Offset Correction: v_off_ini = 0.000000146 V, v_off_fin = 0.000000268 V 17:49:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000862 Vs 17:49:15 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:49:30 Voltage Offset Correction: v_off_ini = 0.000000124 V, v_off_fin = 0.000000094 V 17:49:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000850 Vs 17:49:45 Voltage Offset Correction: v_off_ini = -0.000000088 V, v_off_fin = -0.000000367 V 17:49:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000786 Vs 17:49:46 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:50:01 Voltage Offset Correction: v_off_ini = 0.000000469 V, v_off_fin = 0.000000541 V 17:50:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000833 Vs 17:50:16 Voltage Offset Correction: v_off_ini = 0.000000287 V, v_off_fin = 0.000000202 V 17:50:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000827 Vs 17:50:16 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:50:31 Voltage Offset Correction: v_off_ini = 0.000000271 V, v_off_fin = 0.000000408 V 17:50:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000812 Vs 17:50:46 Voltage Offset Correction: v_off_ini = 0.000000096 V, v_off_fin = -0.000000089 V 17:50:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000888 Vs 17:50:47 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:51:02 Voltage Offset Correction: v_off_ini = 0.000000273 V, v_off_fin = 0.000000502 V 17:51:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000756 Vs 17:51:16 Voltage Offset Correction: v_off_ini = 0.000000318 V, v_off_fin = 0.000000168 V 17:51:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000856 Vs 17:51:17 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:51:32 Voltage Offset Correction: v_off_ini = 0.000000383 V, v_off_fin = 0.000000369 V 17:51:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000819 Vs 17:51:47 Voltage Offset Correction: v_off_ini = 0.000000251 V, v_off_fin = 0.000000322 V 17:51:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000872 Vs 17:51:48 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:52:02 Voltage Offset Correction: v_off_ini = 0.000000131 V, v_off_fin = 0.000000248 V 17:52:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000814 Vs 17:52:17 Voltage Offset Correction: v_off_ini = 0.000000289 V, v_off_fin = 0.000000357 V 17:52:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000824 Vs 17:52:17 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000826 +- 0.000000024 Vs 17:52:17 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000826 +- 0.000000024 Vs BL = 0.00082625 +- 0.00002379 Tm 17:52:24 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00083 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00083 0.00002 0.00083 0.00000 17:52:24 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00083 0.00002 SL = 0.0008263 +- 0.0000238 Tm^2/m^n 17:52:24 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0008263 +- 0.0000238 Tm^2/m^n 17:52:31 Integrated Voltage Measurement... 17:52:32 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:52:47 Voltage Offset Correction: v_off_ini = 0.000000082 V, v_off_fin = 0.000000377 V 17:52:47 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = 0.0010000 m VT = 0.000000935 Vs 17:53:02 Voltage Offset Correction: v_off_ini = 0.000000529 V, v_off_fin = 0.000000417 V 17:53:02 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = -0.0010000 m VT = -0.000000865 Vs 17:53:03 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:53:17 Voltage Offset Correction: v_off_ini = 0.000000409 V, v_off_fin = 0.000000617 V 17:53:17 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = 0.0010000 m VT = 0.000000682 Vs 17:53:32 Voltage Offset Correction: v_off_ini = 0.000000156 V, v_off_fin = 0.000000156 V 17:53:32 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = -0.0010000 m VT = -0.000000634 Vs 17:53:33 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:53:48 Voltage Offset Correction: v_off_ini = 0.000000111 V, v_off_fin = -0.000000155 V 17:53:48 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = 0.0010000 m VT = 0.000000751 Vs 17:54:03 Voltage Offset Correction: v_off_ini = -0.000000047 V, v_off_fin = -0.000000016 V 17:54:03 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = -0.0010000 m VT = -0.000000771 Vs 17:54:03 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:54:18 Voltage Offset Correction: v_off_ini = -0.000000257 V, v_off_fin = 0.000000244 V 17:54:18 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = 0.0010000 m VT = 0.000000813 Vs 17:54:33 Voltage Offset Correction: v_off_ini = 0.000000109 V, v_off_fin = -0.000000239 V 17:54:33 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = -0.0010000 m VT = -0.000000613 Vs 17:54:34 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:54:49 Voltage Offset Correction: v_off_ini = 0.000000397 V, v_off_fin = 0.000000577 V 17:54:49 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = 0.0010000 m VT = 0.000000758 Vs 17:55:04 Voltage Offset Correction: v_off_ini = 0.000000162 V, v_off_fin = 0.000000136 V 17:55:04 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = -0.0010000 m VT = -0.000000828 Vs 17:55:04 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:55:19 Voltage Offset Correction: v_off_ini = 0.000000237 V, v_off_fin = -0.000000068 V 17:55:19 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = 0.0010000 m VT = 0.000000968 Vs 17:55:34 Voltage Offset Correction: v_off_ini = 0.000000377 V, v_off_fin = 0.000000300 V 17:55:34 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = -0.0010000 m VT = -0.000000825 Vs 17:55:35 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:55:50 Voltage Offset Correction: v_off_ini = 0.000000151 V, v_off_fin = 0.000000169 V 17:55:50 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = 0.0010000 m VT = 0.000000781 Vs 17:56:04 Voltage Offset Correction: v_off_ini = 0.000000318 V, v_off_fin = 0.000000356 V 17:56:04 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = -0.0010000 m VT = -0.000000803 Vs 17:56:05 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:56:20 Voltage Offset Correction: v_off_ini = 0.000000418 V, v_off_fin = 0.000000701 V 17:56:20 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = 0.0010000 m VT = 0.000000638 Vs 17:56:35 Voltage Offset Correction: v_off_ini = 0.000000473 V, v_off_fin = 0.000000414 V 17:56:35 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = -0.0010000 m VT = -0.000000838 Vs 17:56:36 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:56:50 Voltage Offset Correction: v_off_ini = -0.000000086 V, v_off_fin = 0.000000365 V 17:56:50 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = 0.0010000 m VT = 0.000000911 Vs 17:57:05 Voltage Offset Correction: v_off_ini = 0.000000042 V, v_off_fin = 0.000000431 V 17:57:05 Integrated Voltage Measurement X0 = -0.0040000 m, Delta X = -0.0010000 m VT = -0.000000804 Vs 17:57:05 Integrated Voltage Average and RMS of Measurements X0 = -0.0040000 m, Delta X = 0.0010000 m VT = 0.000000790 +- 0.000000078 Vs 17:57:05 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0040000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000790 +- 0.000000078 Vs BL = 0.00078999 +- 0.00007805 Tm 17:57:05 Integrated Voltage Measurement... 17:57:06 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:57:21 Voltage Offset Correction: v_off_ini = 0.000000155 V, v_off_fin = 0.000000031 V 17:57:21 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = 0.0010000 m VT = 0.000000831 Vs 17:57:36 Voltage Offset Correction: v_off_ini = 0.000000319 V, v_off_fin = 0.000000411 V 17:57:36 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = -0.0010000 m VT = -0.000000796 Vs 17:57:36 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:57:51 Voltage Offset Correction: v_off_ini = 0.000000300 V, v_off_fin = 0.000000045 V 17:57:51 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = 0.0010000 m VT = 0.000000808 Vs 17:58:06 Voltage Offset Correction: v_off_ini = 0.000000265 V, v_off_fin = 0.000000178 V 17:58:06 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = -0.0010000 m VT = -0.000000871 Vs 17:58:07 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:58:22 Voltage Offset Correction: v_off_ini = 0.000000056 V, v_off_fin = -0.000000028 V 17:58:22 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = 0.0010000 m VT = 0.000000864 Vs 17:58:37 Voltage Offset Correction: v_off_ini = 0.000000317 V, v_off_fin = 0.000000551 V 17:58:37 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = -0.0010000 m VT = -0.000000869 Vs 17:58:37 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:58:52 Voltage Offset Correction: v_off_ini = 0.000000255 V, v_off_fin = 0.000000249 V 17:58:52 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = 0.0010000 m VT = 0.000000816 Vs 17:59:07 Voltage Offset Correction: v_off_ini = 0.000000410 V, v_off_fin = 0.000000235 V 17:59:07 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = -0.0010000 m VT = -0.000000802 Vs 17:59:08 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:59:23 Voltage Offset Correction: v_off_ini = 0.000000205 V, v_off_fin = 0.000000208 V 17:59:23 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = 0.0010000 m VT = 0.000000797 Vs 17:59:37 Voltage Offset Correction: v_off_ini = 0.000000527 V, v_off_fin = 0.000000371 V 17:59:37 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = -0.0010000 m VT = -0.000000786 Vs 17:59:38 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 17:59:53 Voltage Offset Correction: v_off_ini = 0.000000227 V, v_off_fin = 0.000000345 V 17:59:53 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = 0.0010000 m VT = 0.000000890 Vs 18:00:08 Voltage Offset Correction: v_off_ini = 0.000000034 V, v_off_fin = 0.000000018 V 18:00:08 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = -0.0010000 m VT = -0.000000822 Vs 18:00:09 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:00:23 Voltage Offset Correction: v_off_ini = 0.000000308 V, v_off_fin = 0.000000122 V 18:00:23 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = 0.0010000 m VT = 0.000000811 Vs 18:00:38 Voltage Offset Correction: v_off_ini = 0.000000112 V, v_off_fin = 0.000000153 V 18:00:38 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = -0.0010000 m VT = -0.000000828 Vs 18:00:39 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:00:54 Voltage Offset Correction: v_off_ini = 0.000000186 V, v_off_fin = 0.000000435 V 18:00:54 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = 0.0010000 m VT = 0.000000752 Vs 18:01:09 Voltage Offset Correction: v_off_ini = 0.000000158 V, v_off_fin = 0.000000264 V 18:01:09 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = -0.0010000 m VT = -0.000000748 Vs 18:01:09 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000794 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:01:24 Voltage Offset Correction: v_off_ini = 0.000000423 V, v_off_fin = 0.000000398 V 18:01:24 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = 0.0010000 m VT = 0.000000758 Vs 18:01:39 Voltage Offset Correction: v_off_ini = 0.000000246 V, v_off_fin = 0.000000070 V 18:01:39 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = -0.0010000 m VT = -0.000000797 Vs 18:01:39 Integrated Voltage Average and RMS of Measurements X0 = -0.0030000 m, Delta X = 0.0010000 m VT = 0.000000814 +- 0.000000035 Vs 18:01:39 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0030000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000814 +- 0.000000035 Vs BL = 0.00081357 +- 0.00003529 Tm 18:01:39 Integrated Voltage Measurement... 18:01:40 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:01:55 Voltage Offset Correction: v_off_ini = 0.000000377 V, v_off_fin = 0.000000254 V 18:01:55 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = 0.0010000 m VT = 0.000000738 Vs 18:02:10 Voltage Offset Correction: v_off_ini = 0.000000265 V, v_off_fin = 0.000000402 V 18:02:10 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = -0.0010000 m VT = -0.000000909 Vs 18:02:10 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:02:25 Voltage Offset Correction: v_off_ini = 0.000000291 V, v_off_fin = 0.000000149 V 18:02:25 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = 0.0010000 m VT = 0.000000819 Vs 18:02:40 Voltage Offset Correction: v_off_ini = 0.000000328 V, v_off_fin = 0.000000201 V 18:02:40 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = -0.0010000 m VT = -0.000000782 Vs 18:02:41 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:02:56 Voltage Offset Correction: v_off_ini = 0.000000257 V, v_off_fin = 0.000000670 V 18:02:56 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = 0.0010000 m VT = 0.000000846 Vs 18:03:11 Voltage Offset Correction: v_off_ini = 0.000000354 V, v_off_fin = 0.000000493 V 18:03:11 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = -0.0010000 m VT = -0.000000809 Vs 18:03:11 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000794 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:03:26 Voltage Offset Correction: v_off_ini = 0.000000361 V, v_off_fin = 0.000000181 V 18:03:26 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = 0.0010000 m VT = 0.000000812 Vs 18:03:41 Voltage Offset Correction: v_off_ini = 0.000000306 V, v_off_fin = 0.000000041 V 18:03:41 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = -0.0010000 m VT = -0.000000850 Vs 18:03:42 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:03:57 Voltage Offset Correction: v_off_ini = 0.000000193 V, v_off_fin = 0.000000302 V 18:03:57 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = 0.0010000 m VT = 0.000000792 Vs 18:04:11 Voltage Offset Correction: v_off_ini = 0.000000205 V, v_off_fin = 0.000000728 V 18:04:11 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = -0.0010000 m VT = -0.000000908 Vs 18:04:12 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:04:27 Voltage Offset Correction: v_off_ini = 0.000000120 V, v_off_fin = 0.000000145 V 18:04:27 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = 0.0010000 m VT = 0.000000794 Vs 18:04:42 Voltage Offset Correction: v_off_ini = 0.000000379 V, v_off_fin = 0.000000174 V 18:04:42 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = -0.0010000 m VT = -0.000000791 Vs 18:04:42 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:04:57 Voltage Offset Correction: v_off_ini = 0.000000120 V, v_off_fin = 0.000000262 V 18:04:57 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = 0.0010000 m VT = 0.000000820 Vs 18:05:12 Voltage Offset Correction: v_off_ini = 0.000000181 V, v_off_fin = 0.000000086 V 18:05:12 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = -0.0010000 m VT = -0.000000772 Vs 18:05:13 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:05:28 Voltage Offset Correction: v_off_ini = 0.000000354 V, v_off_fin = 0.000000395 V 18:05:28 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = 0.0010000 m VT = 0.000000901 Vs 18:05:43 Voltage Offset Correction: v_off_ini = 0.000000023 V, v_off_fin = 0.000000131 V 18:05:43 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = -0.0010000 m VT = -0.000000794 Vs 18:05:43 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:05:58 Voltage Offset Correction: v_off_ini = 0.000000125 V, v_off_fin = -0.000000399 V 18:05:58 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = 0.0010000 m VT = 0.000000867 Vs 18:06:13 Voltage Offset Correction: v_off_ini = 0.000000265 V, v_off_fin = -0.000000111 V 18:06:13 Integrated Voltage Measurement X0 = -0.0020000 m, Delta X = -0.0010000 m VT = -0.000000874 Vs 18:06:13 Integrated Voltage Average and RMS of Measurements X0 = -0.0020000 m, Delta X = 0.0010000 m VT = 0.000000827 +- 0.000000025 Vs 18:06:13 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0020000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000827 +- 0.000000025 Vs BL = 0.00082655 +- 0.00002524 Tm 18:06:13 Integrated Voltage Measurement... 18:06:14 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:06:29 Voltage Offset Correction: v_off_ini = 0.000000162 V, v_off_fin = 0.000000486 V 18:06:29 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0010000 m VT = 0.000000822 Vs 18:06:43 Voltage Offset Correction: v_off_ini = 0.000000224 V, v_off_fin = 0.000000247 V 18:06:43 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0010000 m VT = -0.000000809 Vs 18:06:44 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:06:59 Voltage Offset Correction: v_off_ini = 0.000000535 V, v_off_fin = 0.000000752 V 18:06:59 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0010000 m VT = 0.000000821 Vs 18:07:14 Voltage Offset Correction: v_off_ini = 0.000000321 V, v_off_fin = 0.000000552 V 18:07:14 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0010000 m VT = -0.000000809 Vs 18:07:15 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:07:29 Voltage Offset Correction: v_off_ini = 0.000000446 V, v_off_fin = 0.000000568 V 18:07:29 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0010000 m VT = 0.000000868 Vs 18:07:44 Voltage Offset Correction: v_off_ini = 0.000000270 V, v_off_fin = 0.000000358 V 18:07:44 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0010000 m VT = -0.000000788 Vs 18:07:45 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:08:00 Voltage Offset Correction: v_off_ini = 0.000000459 V, v_off_fin = 0.000000483 V 18:08:00 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0010000 m VT = 0.000000779 Vs 18:08:15 Voltage Offset Correction: v_off_ini = 0.000000549 V, v_off_fin = 0.000000297 V 18:08:15 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0010000 m VT = -0.000000854 Vs 18:08:15 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:08:30 Voltage Offset Correction: v_off_ini = 0.000000253 V, v_off_fin = 0.000000061 V 18:08:30 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0010000 m VT = 0.000000830 Vs 18:08:45 Voltage Offset Correction: v_off_ini = 0.000000347 V, v_off_fin = 0.000000387 V 18:08:45 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0010000 m VT = -0.000000830 Vs 18:08:46 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:09:01 Voltage Offset Correction: v_off_ini = 0.000000306 V, v_off_fin = 0.000000316 V 18:09:01 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0010000 m VT = 0.000000836 Vs 18:09:16 Voltage Offset Correction: v_off_ini = 0.000000279 V, v_off_fin = 0.000000248 V 18:09:16 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0010000 m VT = -0.000000811 Vs 18:09:16 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:09:31 Voltage Offset Correction: v_off_ini = 0.000000250 V, v_off_fin = 0.000000442 V 18:09:31 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0010000 m VT = 0.000000824 Vs 18:09:46 Voltage Offset Correction: v_off_ini = 0.000000269 V, v_off_fin = 0.000000189 V 18:09:46 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0010000 m VT = -0.000000838 Vs 18:09:47 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:10:02 Voltage Offset Correction: v_off_ini = 0.000000020 V, v_off_fin = 0.000000070 V 18:10:02 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0010000 m VT = 0.000000850 Vs 18:10:17 Voltage Offset Correction: v_off_ini = 0.000000317 V, v_off_fin = 0.000000166 V 18:10:17 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0010000 m VT = -0.000000815 Vs 18:10:17 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:10:32 Voltage Offset Correction: v_off_ini = 0.000000334 V, v_off_fin = 0.000000118 V 18:10:32 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0010000 m VT = 0.000000822 Vs 18:10:47 Voltage Offset Correction: v_off_ini = 0.000000300 V, v_off_fin = 0.000000062 V 18:10:47 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0010000 m VT = -0.000000872 Vs 18:10:47 Integrated Voltage Average and RMS of Measurements X0 = -0.0010000 m, Delta X = 0.0010000 m VT = 0.000000827 +- 0.000000010 Vs 18:10:47 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0010000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000827 +- 0.000000010 Vs BL = 0.00082661 +- 0.00000982 Tm 18:10:47 Integrated Voltage Measurement... 18:10:48 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:11:03 Voltage Offset Correction: v_off_ini = 0.000000304 V, v_off_fin = 0.000000225 V 18:11:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000802 Vs 18:11:17 Voltage Offset Correction: v_off_ini = 0.000000238 V, v_off_fin = 0.000000094 V 18:11:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000822 Vs 18:11:18 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:11:33 Voltage Offset Correction: v_off_ini = 0.000000552 V, v_off_fin = 0.000000534 V 18:11:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000782 Vs 18:11:48 Voltage Offset Correction: v_off_ini = 0.000000348 V, v_off_fin = 0.000000248 V 18:11:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000823 Vs 18:11:49 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:12:03 Voltage Offset Correction: v_off_ini = 0.000000388 V, v_off_fin = 0.000000513 V 18:12:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000813 Vs 18:12:18 Voltage Offset Correction: v_off_ini = 0.000000355 V, v_off_fin = 0.000000373 V 18:12:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000857 Vs 18:12:19 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:12:34 Voltage Offset Correction: v_off_ini = 0.000000317 V, v_off_fin = 0.000000621 V 18:12:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000818 Vs 18:12:49 Voltage Offset Correction: v_off_ini = 0.000000216 V, v_off_fin = 0.000000192 V 18:12:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000857 Vs 18:12:49 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:13:04 Voltage Offset Correction: v_off_ini = 0.000000331 V, v_off_fin = 0.000000022 V 18:13:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000850 Vs 18:13:19 Voltage Offset Correction: v_off_ini = 0.000000328 V, v_off_fin = 0.000000207 V 18:13:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000813 Vs 18:13:20 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:13:35 Voltage Offset Correction: v_off_ini = 0.000000439 V, v_off_fin = 0.000000401 V 18:13:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000871 Vs 18:13:50 Voltage Offset Correction: v_off_ini = 0.000000251 V, v_off_fin = 0.000000495 V 18:13:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000843 Vs 18:13:50 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:14:05 Voltage Offset Correction: v_off_ini = 0.000000292 V, v_off_fin = 0.000000646 V 18:14:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000805 Vs 18:14:20 Voltage Offset Correction: v_off_ini = 0.000000328 V, v_off_fin = 0.000000550 V 18:14:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000826 Vs 18:14:21 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:14:36 Voltage Offset Correction: v_off_ini = 0.000000328 V, v_off_fin = 0.000000069 V 18:14:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000847 Vs 18:14:51 Voltage Offset Correction: v_off_ini = 0.000000480 V, v_off_fin = 0.000000420 V 18:14:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000815 Vs 18:14:51 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:15:06 Voltage Offset Correction: v_off_ini = 0.000000480 V, v_off_fin = 0.000000256 V 18:15:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000809 Vs 18:15:21 Voltage Offset Correction: v_off_ini = 0.000000364 V, v_off_fin = 0.000000330 V 18:15:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0010000 m VT = -0.000000796 Vs 18:15:21 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0010000 m VT = 0.000000825 +- 0.000000017 Vs 18:15:21 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000825 +- 0.000000017 Vs BL = 0.00082502 +- 0.00001708 Tm 18:15:21 Integrated Voltage Measurement... 18:15:22 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:15:37 Voltage Offset Correction: v_off_ini = 0.000000584 V, v_off_fin = 0.000000483 V 18:15:37 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0010000 m VT = 0.000000848 Vs 18:15:51 Voltage Offset Correction: v_off_ini = 0.000000499 V, v_off_fin = 0.000000358 V 18:15:51 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0010000 m VT = -0.000000787 Vs 18:15:52 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:16:07 Voltage Offset Correction: v_off_ini = 0.000000198 V, v_off_fin = 0.000000149 V 18:16:07 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0010000 m VT = 0.000000823 Vs 18:16:22 Voltage Offset Correction: v_off_ini = 0.000000416 V, v_off_fin = 0.000000299 V 18:16:22 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0010000 m VT = -0.000000854 Vs 18:16:22 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:16:37 Voltage Offset Correction: v_off_ini = 0.000000378 V, v_off_fin = 0.000000160 V 18:16:37 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0010000 m VT = 0.000000844 Vs 18:16:52 Voltage Offset Correction: v_off_ini = 0.000000487 V, v_off_fin = 0.000000587 V 18:16:52 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0010000 m VT = -0.000000849 Vs 18:16:53 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:17:08 Voltage Offset Correction: v_off_ini = 0.000000229 V, v_off_fin = -0.000000193 V 18:17:08 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0010000 m VT = 0.000000916 Vs 18:17:23 Voltage Offset Correction: v_off_ini = 0.000000482 V, v_off_fin = 0.000000504 V 18:17:23 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0010000 m VT = -0.000000812 Vs 18:17:23 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:17:38 Voltage Offset Correction: v_off_ini = 0.000000291 V, v_off_fin = 0.000000317 V 18:17:38 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0010000 m VT = 0.000000799 Vs 18:17:53 Voltage Offset Correction: v_off_ini = 0.000000280 V, v_off_fin = 0.000000224 V 18:17:53 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0010000 m VT = -0.000000832 Vs 18:17:54 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:18:09 Voltage Offset Correction: v_off_ini = 0.000000380 V, v_off_fin = 0.000000069 V 18:18:09 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0010000 m VT = 0.000000836 Vs 18:18:23 Voltage Offset Correction: v_off_ini = 0.000000378 V, v_off_fin = 0.000000305 V 18:18:23 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0010000 m VT = -0.000000831 Vs 18:18:24 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:18:39 Voltage Offset Correction: v_off_ini = 0.000000531 V, v_off_fin = 0.000000511 V 18:18:39 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0010000 m VT = 0.000000875 Vs 18:18:54 Voltage Offset Correction: v_off_ini = 0.000000401 V, v_off_fin = 0.000000420 V 18:18:54 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0010000 m VT = -0.000000850 Vs 18:18:55 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:19:09 Voltage Offset Correction: v_off_ini = 0.000000312 V, v_off_fin = 0.000000339 V 18:19:09 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0010000 m VT = 0.000000844 Vs 18:19:24 Voltage Offset Correction: v_off_ini = 0.000000262 V, v_off_fin = 0.000000250 V 18:19:24 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0010000 m VT = -0.000000796 Vs 18:19:25 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:19:40 Voltage Offset Correction: v_off_ini = 0.000000707 V, v_off_fin = 0.000000617 V 18:19:40 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0010000 m VT = 0.000000744 Vs 18:19:55 Voltage Offset Correction: v_off_ini = 0.000000124 V, v_off_fin = 0.000000200 V 18:19:55 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0010000 m VT = -0.000000798 Vs 18:19:55 Integrated Voltage Average and RMS of Measurements X0 = 0.0010000 m, Delta X = 0.0010000 m VT = 0.000000830 +- 0.000000027 Vs 18:19:55 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0010000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000830 +- 0.000000027 Vs BL = 0.00082988 +- 0.00002701 Tm 18:19:55 Integrated Voltage Measurement... 18:19:55 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:20:10 Voltage Offset Correction: v_off_ini = 0.000000281 V, v_off_fin = 0.000000643 V 18:20:10 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = 0.0010000 m VT = 0.000000789 Vs 18:20:25 Voltage Offset Correction: v_off_ini = 0.000000156 V, v_off_fin = 0.000000099 V 18:20:25 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = -0.0010000 m VT = -0.000000779 Vs 18:20:26 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:20:41 Voltage Offset Correction: v_off_ini = 0.000000338 V, v_off_fin = 0.000000621 V 18:20:41 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = 0.0010000 m VT = 0.000000727 Vs 18:20:56 Voltage Offset Correction: v_off_ini = 0.000000425 V, v_off_fin = 0.000000602 V 18:20:56 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = -0.0010000 m VT = -0.000000884 Vs 18:20:56 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:21:11 Voltage Offset Correction: v_off_ini = 0.000000380 V, v_off_fin = 0.000000248 V 18:21:11 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = 0.0010000 m VT = 0.000000815 Vs 18:21:26 Voltage Offset Correction: v_off_ini = 0.000000376 V, v_off_fin = 0.000000459 V 18:21:26 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = -0.0010000 m VT = -0.000000793 Vs 18:21:27 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:21:42 Voltage Offset Correction: v_off_ini = 0.000000337 V, v_off_fin = 0.000000371 V 18:21:42 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = 0.0010000 m VT = 0.000000771 Vs 18:21:57 Voltage Offset Correction: v_off_ini = 0.000000286 V, v_off_fin = 0.000000386 V 18:21:57 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = -0.0010000 m VT = -0.000000820 Vs 18:21:57 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:22:12 Voltage Offset Correction: v_off_ini = 0.000000512 V, v_off_fin = 0.000000518 V 18:22:12 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = 0.0010000 m VT = 0.000000796 Vs 18:22:27 Voltage Offset Correction: v_off_ini = 0.000000475 V, v_off_fin = 0.000000663 V 18:22:27 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = -0.0010000 m VT = -0.000000784 Vs 18:22:28 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:22:43 Voltage Offset Correction: v_off_ini = 0.000000516 V, v_off_fin = 0.000000541 V 18:22:43 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = 0.0010000 m VT = 0.000000833 Vs 18:22:58 Voltage Offset Correction: v_off_ini = 0.000000091 V, v_off_fin = -0.000000041 V 18:22:58 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = -0.0010000 m VT = -0.000000813 Vs 18:22:58 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:23:13 Voltage Offset Correction: v_off_ini = 0.000000420 V, v_off_fin = 0.000000150 V 18:23:13 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = 0.0010000 m VT = 0.000000815 Vs 18:23:28 Voltage Offset Correction: v_off_ini = 0.000000496 V, v_off_fin = 0.000000413 V 18:23:28 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = -0.0010000 m VT = -0.000000831 Vs 18:23:29 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000798 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:23:44 Voltage Offset Correction: v_off_ini = 0.000000079 V, v_off_fin = 0.000000194 V 18:23:44 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = 0.0010000 m VT = 0.000000784 Vs 18:23:58 Voltage Offset Correction: v_off_ini = 0.000000247 V, v_off_fin = 0.000000358 V 18:23:58 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = -0.0010000 m VT = -0.000000817 Vs 18:23:59 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:24:14 Voltage Offset Correction: v_off_ini = 0.000000462 V, v_off_fin = 0.000000664 V 18:24:14 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = 0.0010000 m VT = 0.000000784 Vs 18:24:29 Voltage Offset Correction: v_off_ini = 0.000000224 V, v_off_fin = 0.000000237 V 18:24:29 Integrated Voltage Measurement X0 = 0.0020000 m, Delta X = -0.0010000 m VT = -0.000000779 Vs 18:24:29 Integrated Voltage Average and RMS of Measurements X0 = 0.0020000 m, Delta X = 0.0010000 m VT = 0.000000801 +- 0.000000014 Vs 18:24:29 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0020000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000801 +- 0.000000014 Vs BL = 0.00080085 +- 0.00001419 Tm 18:24:29 Integrated Voltage Measurement... 18:24:29 Magnet Current for Main , Imag = 12.0096 A Vtrans = 1.000797 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:24:44 Voltage Offset Correction: v_off_ini = 0.000000657 V, v_off_fin = 0.000000424 V 18:24:44 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = 0.0010000 m VT = 0.000000797 Vs 18:24:59 Voltage Offset Correction: v_off_ini = 0.000000278 V, v_off_fin = 0.000000708 V 18:24:59 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = -0.0010000 m VT = -0.000000816 Vs 18:25:00 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:25:15 Voltage Offset Correction: v_off_ini = 0.000000454 V, v_off_fin = 0.000000269 V 18:25:15 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = 0.0010000 m VT = 0.000000783 Vs 18:25:30 Voltage Offset Correction: v_off_ini = 0.000000371 V, v_off_fin = 0.000000325 V 18:25:30 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = -0.0010000 m VT = -0.000000784 Vs 18:25:30 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000796 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:25:45 Voltage Offset Correction: v_off_ini = 0.000000285 V, v_off_fin = 0.000000645 V 18:25:45 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = 0.0010000 m VT = 0.000000791 Vs 18:26:00 Voltage Offset Correction: v_off_ini = 0.000000382 V, v_off_fin = 0.000000299 V 18:26:00 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = -0.0010000 m VT = -0.000000769 Vs 18:26:01 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000793 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:26:16 Voltage Offset Correction: v_off_ini = 0.000000490 V, v_off_fin = -0.000000205 V 18:26:16 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = 0.0010000 m VT = 0.000000784 Vs 18:26:31 Voltage Offset Correction: v_off_ini = 0.000000210 V, v_off_fin = 0.000000685 V 18:26:31 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = -0.0010000 m VT = -0.000000872 Vs 18:26:31 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:26:46 Voltage Offset Correction: v_off_ini = 0.000000462 V, v_off_fin = 0.000000252 V 18:26:46 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = 0.0010000 m VT = 0.000000854 Vs 18:27:01 Voltage Offset Correction: v_off_ini = 0.000000540 V, v_off_fin = 0.000000302 V 18:27:01 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = -0.0010000 m VT = -0.000000875 Vs 18:27:02 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000794 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:27:16 Voltage Offset Correction: v_off_ini = 0.000000186 V, v_off_fin = 0.000000407 V 18:27:16 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = 0.0010000 m VT = 0.000000918 Vs 18:27:31 Voltage Offset Correction: v_off_ini = 0.000000489 V, v_off_fin = 0.000000238 V 18:27:31 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = -0.0010000 m VT = -0.000000871 Vs 18:27:32 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000794 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:27:47 Voltage Offset Correction: v_off_ini = 0.000000309 V, v_off_fin = 0.000000877 V 18:27:47 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = 0.0010000 m VT = 0.000000784 Vs 18:28:02 Voltage Offset Correction: v_off_ini = 0.000000187 V, v_off_fin = 0.000000398 V 18:28:02 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = -0.0010000 m VT = -0.000000842 Vs 18:28:02 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000794 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:28:17 Voltage Offset Correction: v_off_ini = 0.000000262 V, v_off_fin = 0.000000640 V 18:28:17 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = 0.0010000 m VT = 0.000000807 Vs 18:28:32 Voltage Offset Correction: v_off_ini = 0.000000603 V, v_off_fin = 0.000000354 V 18:28:32 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = -0.0010000 m VT = -0.000000863 Vs 18:28:33 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000794 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:28:48 Voltage Offset Correction: v_off_ini = 0.000000234 V, v_off_fin = 0.000000415 V 18:28:48 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = 0.0010000 m VT = 0.000000801 Vs 18:29:03 Voltage Offset Correction: v_off_ini = 0.000000598 V, v_off_fin = 0.000000559 V 18:29:03 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = -0.0010000 m VT = -0.000000828 Vs 18:29:03 Integrated Voltage Average and RMS of Measurements X0 = 0.0030000 m, Delta X = 0.0010000 m VT = 0.000000824 +- 0.000000035 Vs 18:29:03 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0030000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000824 +- 0.000000035 Vs BL = 0.00082443 +- 0.00003477 Tm 18:29:03 Integrated Voltage Measurement... 18:29:03 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000794 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:29:18 Voltage Offset Correction: v_off_ini = 0.000000355 V, v_off_fin = 0.000000289 V 18:29:18 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = 0.0010000 m VT = 0.000000825 Vs 18:29:33 Voltage Offset Correction: v_off_ini = 0.000000362 V, v_off_fin = -0.000000210 V 18:29:33 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = -0.0010000 m VT = -0.000000860 Vs 18:29:34 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000794 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:29:49 Voltage Offset Correction: v_off_ini = 0.000000436 V, v_off_fin = 0.000000058 V 18:29:49 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = 0.0010000 m VT = 0.000000845 Vs 18:30:04 Voltage Offset Correction: v_off_ini = 0.000000052 V, v_off_fin = 0.000000219 V 18:30:04 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = -0.0010000 m VT = -0.000000796 Vs 18:30:04 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000793 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:30:19 Voltage Offset Correction: v_off_ini = 0.000000353 V, v_off_fin = 0.000000830 V 18:30:19 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = 0.0010000 m VT = 0.000000741 Vs 18:30:34 Voltage Offset Correction: v_off_ini = 0.000000764 V, v_off_fin = 0.000000518 V 18:30:34 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = -0.0010000 m VT = -0.000000860 Vs 18:30:35 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000792 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:30:50 Voltage Offset Correction: v_off_ini = 0.000000080 V, v_off_fin = 0.000000011 V 18:30:50 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = 0.0010000 m VT = 0.000000817 Vs 18:31:04 Voltage Offset Correction: v_off_ini = 0.000001001 V, v_off_fin = 0.000000571 V 18:31:04 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = -0.0010000 m VT = -0.000000999 Vs 18:31:05 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000794 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:31:20 Voltage Offset Correction: v_off_ini = 0.000000006 V, v_off_fin = 0.000000501 V 18:31:20 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = 0.0010000 m VT = 0.000000729 Vs 18:31:35 Voltage Offset Correction: v_off_ini = 0.000000031 V, v_off_fin = 0.000000122 V 18:31:35 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = -0.0010000 m VT = -0.000000704 Vs 18:31:36 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000794 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:31:50 Voltage Offset Correction: v_off_ini = 0.000000307 V, v_off_fin = 0.000000160 V 18:31:50 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = 0.0010000 m VT = 0.000000859 Vs 18:32:05 Voltage Offset Correction: v_off_ini = 0.000000728 V, v_off_fin = 0.000000598 V 18:32:05 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = -0.0010000 m VT = -0.000000927 Vs 18:32:06 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000793 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:32:21 Voltage Offset Correction: v_off_ini = 0.000000424 V, v_off_fin = 0.000000897 V 18:32:21 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = 0.0010000 m VT = 0.000000732 Vs 18:32:36 Voltage Offset Correction: v_off_ini = 0.000000558 V, v_off_fin = 0.000000136 V 18:32:36 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = -0.0010000 m VT = -0.000000884 Vs 18:32:36 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:32:51 Voltage Offset Correction: v_off_ini = 0.000000150 V, v_off_fin = 0.000000222 V 18:32:51 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = 0.0010000 m VT = 0.000000855 Vs 18:33:06 Voltage Offset Correction: v_off_ini = 0.000000592 V, v_off_fin = 0.000000239 V 18:33:06 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = -0.0010000 m VT = -0.000000933 Vs 18:33:07 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000792 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:33:22 Voltage Offset Correction: v_off_ini = 0.000000333 V, v_off_fin = 0.000000486 V 18:33:22 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = 0.0010000 m VT = 0.000000854 Vs 18:33:37 Voltage Offset Correction: v_off_ini = 0.000000415 V, v_off_fin = 0.000000440 V 18:33:37 Integrated Voltage Measurement X0 = 0.0040000 m, Delta X = -0.0010000 m VT = -0.000000798 Vs 18:33:37 Integrated Voltage Average and RMS of Measurements X0 = 0.0040000 m, Delta X = 0.0010000 m VT = 0.000000834 +- 0.000000056 Vs 18:33:37 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0040000 m, dx = 0.0010000 m, Nturns = 1.0 VT = 0.000000834 +- 0.000000056 Vs BL = 0.00083435 +- 0.00005618 Tm 18:33:45 Magnet Current for Main , Imag = 12.0095 A Vtrans = 1.000795 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 18:33:45 Magnet Voltage Measurement, V = 0.000000 V 18:33:45 Temperature Measurement, Probe Number = 0, T = 20.275000 C 18:33:46 Sensor Voltage Measurement, Sensor Number = 0, V = 1.647482 V 18:33:46 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.647482 (V, A, ohm, ...), Measured Value = 18.992801 (C, atm, Hz, ...) 18:33:46 Sensor Voltage Measurement, Sensor Number = 1, V = 1.672716 V 18:33:46 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 1.672716 (V, A, ohm, ...), Measured Value = 19.343275 (C, atm, Hz, ...) 18:33:47 Sensor Voltage Measurement, Sensor Number = 2, V = 1.005771 V 18:33:47 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.005771 (V, A, ohm, ...), Measured Value = 0.432840 (C, atm, Hz, ...) 18:33:48 Sensor Voltage Measurement, Sensor Number = 3, V = 1.002088 V 18:33:48 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002088 (V, A, ohm, ...), Measured Value = 0.156615 (C, atm, Hz, ...) 18:33:48 Sensor Voltage Measurement, Sensor Number = 4, V = 0.004342 V 18:33:48 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = 0.004342 (V, A, ohm, ...), Measured Value = 0.000737 (C, atm, Hz, ...) 18:33:48 Magnet Test Parameter Measurements P0 = Main , Value = 12.01 P1 = Magnet voltage (V), Value = 0.00 P2 = Ambient, Value = 20.27 P3 = Supply Temp(C), Value = 18.99 P4 = Return Temp(C), Value = 19.34 P5 = Supply Pres(psi), Value = 0.43 P6 = Return Pres(psi), Value = 0.16 P7 = Flow Rate(gpm), Value = 0.00 18:34:00 Magnet system Main current ramping to 0.0000 A...