SLAC Magnetic Measurements
Date: 07-06-2012
Time: 14:57:58

Project: Calibration
Magnet Type: Dipole
Magnet Name: CD1
Serial Number: 
Run Number: 9
Measurement Device: 10wire
Operator: sda
Comment: Integrated strength at 12 amps 3 times. dx = 0.04 m new code

Standardization for     Main :
     5 cycles from    0.0 A to   12.0 A to    0.0 A
Test Currents for Main  (A): 
     12.00     12.00     12.00



                Integrated Dipole Strength     
Distance the wire was to be moved = 0.040000 m
Number of turns in the wire = 10
Number of measurements for averaging = 4

      Main    +/- sigma            BL        sigBL            BL/I        sigBL/I   
        (A)        (A)             (Tm)       (Tm)            (Tm/A)       (Tm/A)    
   ------------+----------   -------------+------------   -------------+------------- 
       12.0054    0.0005        0.016705     0.000001        0.001391     0.000000 
       12.0064    0.0001        0.016706     0.000001        0.001391     0.000000 
       12.0067    0.0000        0.016707     0.000001        0.001391     0.000000 