SLAC Magnetic Measurements Date: 07-06-2012 Time: 14:41:55 Project: Calibration Magnet Type: Dipole Magnet Name: CD1 Serial Number: Run Number: 8 Measurement Device: 10 wire Operator: sda Comment: Integrated strength at 12 amps 3 times. dx = 0.04 m using old code Standardization for Main : 5 cycles from 0.0 A to 12.0 A to 0.0 A Test Currents for Main (A): 12.00 12.00 12.00 Integrated Dipole Strength Distance the wire was to be moved = 0.040000 m Number of turns in the wire = 10 Number of measurements for averaging = 4 Main +/- sigma BL sigBL BL/I sigBL/I (A) (A) (Tm) (Tm) (Tm/A) (Tm/A) ------------+---------- -------------+------------ -------------+------------- 12.0051 0.0004 0.016705 0.000000 0.001392 0.000000 12.0061 0.0001 0.016706 0.000000 0.001391 0.000000 12.0064 0.0000 0.016706 0.000001 0.001391 0.000000