SLAC Magnetic Measurements
Date: 07-06-2012
Time: 14:21:39

Project: Calibration
Magnet Type: Dipole
Magnet Name: CD1
Serial Number: 
Run Number: 7
Measurement Device: 10wire
Operator: sda
Comment: Integrated strength at 12 amps 3 times. dx = 0.04 m new code

Standardization for     Main :
     5 cycles from    0.0 A to   12.0 A to    0.0 A
Test Currents for Main  (A): 
     12.00     12.00     12.00



                Integrated Dipole Strength     
Distance the wire was to be moved = 0.040000 m
Number of turns in the wire = 10
Number of measurements for averaging = 4

      Main    +/- sigma            BL        sigBL            BL/I        sigBL/I   
        (A)        (A)             (Tm)       (Tm)            (Tm/A)       (Tm/A)    
   ------------+----------   -------------+------------   -------------+------------- 
       12.0041    0.0005        0.016713     0.000001        0.001392     0.000000 
       12.0052    0.0001        0.016715     0.000002        0.001392     0.000000 
       12.0057    0.0001        0.016715     0.000001        0.001392     0.000000 