SLAC Magnetic Measurements Date: 08-01-2000 Time: 09:48:45 Project: spear3 Magnet Type: gdipole Magnet Name: alssb25 Serial Number: Run Number: 33 Measurement Device: single wire Operator: zw Comment: BL vs I at X=0 Standardization: 1 cycles from 0.0 A to 911.0 A to 0.0 A Test Currents (A): 100.0 200.0 300.0 400.0 500.0 600.0 700.0 800.0 900.0 850.0 800.0 750.0 700.0 600.0 500.0 400.0 300.0 200.0 100.0 09:48:59 Magnet Current, Imag = -0.0021 A Vtrans = -0.000021 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 09:49:00 Magnet Current, Imag = -0.0016 A Vtrans = -0.000016 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 09:49:02 Magnet Current, Imag = -0.0012 A Vtrans = -0.000012 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 09:49:04 Magnet Current, Imag = -0.0009 A Vtrans = -0.000009 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 09:49:04 Magnet Current Measurement: Imag = -0.0015 +- 0.0004 A 09:49:09 Initial Zero Current Measurement, Imag_zero = -0.0015 A 09:49:10 Magnet current ramping to 15.0000 A... 09:50:06 Magnet current ramping to 911.0000 A... 09:54:41 Magnet current ramping to 0.0000 A... 09:59:21 Magnet current ramping to 100.0000 A... 10:00:22 Magnet Current, Imag = 100.0281 A Vtrans = 1.000266 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:00:24 Magnet Current, Imag = 100.1091 A Vtrans = 1.001076 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:00:25 Magnet Current, Imag = 100.0298 A Vtrans = 1.000283 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:00:26 Magnet Current, Imag = 100.0346 A Vtrans = 1.000331 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:00:26 Magnet Current Measurement: Imag = 100.0504 +- 0.0340 A 10:00:26 Magnetic Field Measurement Measuring the magnet strength... 10:00:27 Integrated Voltage Measurement... 10:00:40 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.001234 (Vs) 10:00:51 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.001212 (Vs) 10:01:02 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.001238 (Vs) 10:01:12 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.001209 (Vs) 10:01:23 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.001247 (Vs) 10:01:34 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.001206 (Vs) 10:01:45 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.001246 (Vs) 10:01:55 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.001203 (Vs) 10:01:55 Integrated Voltage Average and RMS of Measurements X0 = 0.000000 (m), Delta X = 0.010000 (m) VT = 0.001224 +- 0.000001 (Vs) 10:01:56 Integrated Field Strength, Average and RMS of Measurements X0 = 0.000000 (m), dx = 0.010000 (m), Nturns = 1.000000 VT = 0.001224 +- 0.000001 (Vs) BL = 0.122431 +- 0.000125 (Tm) 10:01:59 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.12243 0.00013 SL = 0.1224311 +- 0.0001251 Tm^2/m^n 10:01:59 Magnet Strength Measurement Harmonic Number = 1 SL = 0.1224311 +- 0.0001251 Tm^2/m^n 10:02:01 Magnet Current, Imag = 100.0622 A Vtrans = 1.000607 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:02:02 Magnet Current, Imag = 100.0375 A Vtrans = 1.000360 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:02:03 Magnet Current, Imag = 100.0826 A Vtrans = 1.000811 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:02:05 Magnet Current, Imag = 100.0770 A Vtrans = 1.000755 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:02:05 Magnet Current Measurement: Imag = 100.0648 +- 0.0174 A 10:02:05 Magnet current ramping to 200.0000 A... 10:03:06 Magnet Current, Imag = 200.0044 A Vtrans = 2.000029 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:03:07 Magnet Current, Imag = 200.0833 A Vtrans = 2.000818 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:03:09 Magnet Current, Imag = 200.1090 A Vtrans = 2.001075 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:03:10 Magnet Current, Imag = 200.0793 A Vtrans = 2.000778 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:03:10 Magnet Current Measurement: Imag = 200.0690 +- 0.0390 A 10:03:10 Magnetic Field Measurement Measuring the magnet strength... 10:03:10 Integrated Voltage Measurement... 10:03:24 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.002443 (Vs) 10:03:35 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.002436 (Vs) 10:03:46 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.002449 (Vs) 10:03:57 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.002435 (Vs) 10:04:07 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.002442 (Vs) 10:04:18 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.002423 (Vs) 10:04:29 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.002445 (Vs) 10:04:40 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.002421 (Vs) 10:04:40 Integrated Voltage Average and RMS of Measurements X0 = 0.000000 (m), Delta X = 0.010000 (m) VT = 0.002437 +- 0.000004 (Vs) 10:04:40 Integrated Field Strength, Average and RMS of Measurements X0 = 0.000000 (m), dx = 0.010000 (m), Nturns = 1.000000 VT = 0.002437 +- 0.000004 (Vs) BL = 0.243676 +- 0.000412 (Tm) 10:04:43 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.24368 0.00041 SL = 0.2436762 +- 0.0004122 Tm^2/m^n 10:04:43 Magnet Strength Measurement Harmonic Number = 1 SL = 0.2436762 +- 0.0004122 Tm^2/m^n 10:04:45 Magnet Current, Imag = 200.0689 A Vtrans = 2.000674 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:04:46 Magnet Current, Imag = 200.0369 A Vtrans = 2.000354 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:04:47 Magnet Current, Imag = 200.0995 A Vtrans = 2.000980 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:04:49 Magnet Current, Imag = 200.0416 A Vtrans = 2.000401 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:04:49 Magnet Current Measurement: Imag = 200.0617 +- 0.0250 A 10:04:49 Magnet current ramping to 300.0000 A... 10:05:50 Magnet Current, Imag = 300.7649 A Vtrans = 3.007634 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:05:52 Magnet Current, Imag = 300.7544 A Vtrans = 3.007529 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:05:53 Magnet Current, Imag = 300.8063 A Vtrans = 3.008048 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:05:54 Magnet Current, Imag = 300.7714 A Vtrans = 3.007699 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:05:54 Magnet Current Measurement: Imag = 300.7742 +- 0.0195 A 10:05:55 Magnetic Field Measurement Measuring the magnet strength... 10:05:55 Integrated Voltage Measurement... 10:06:08 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.003686 (Vs) 10:06:19 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.003656 (Vs) 10:06:30 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.003686 (Vs) 10:06:41 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.003658 (Vs) 10:06:51 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.003701 (Vs) 10:07:02 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.003660 (Vs) 10:07:13 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.003682 (Vs) 10:07:24 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.003663 (Vs) 10:07:24 Integrated Voltage Average and RMS of Measurements X0 = 0.000000 (m), Delta X = 0.010000 (m) VT = 0.003674 +- 0.000004 (Vs) 10:07:24 Integrated Field Strength, Average and RMS of Measurements X0 = 0.000000 (m), dx = 0.010000 (m), Nturns = 1.000000 VT = 0.003674 +- 0.000004 (Vs) BL = 0.367418 +- 0.000372 (Tm) 10:07:27 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.36742 0.00037 SL = 0.3674175 +- 0.0003722 Tm^2/m^n 10:07:27 Magnet Strength Measurement Harmonic Number = 1 SL = 0.3674175 +- 0.0003722 Tm^2/m^n 10:07:29 Magnet Current, Imag = 300.8280 A Vtrans = 3.008265 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:07:30 Magnet Current, Imag = 300.7783 A Vtrans = 3.007768 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:07:31 Magnet Current, Imag = 300.7501 A Vtrans = 3.007486 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:07:33 Magnet Current, Imag = 300.7892 A Vtrans = 3.007877 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:07:33 Magnet Current Measurement: Imag = 300.7864 +- 0.0279 A 10:07:33 Magnet current ramping to 400.0000 A... 10:08:35 Magnet Current, Imag = 400.9065 A Vtrans = 4.009050 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:08:36 Magnet Current, Imag = 400.8385 A Vtrans = 4.008370 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:08:37 Magnet Current, Imag = 400.8805 A Vtrans = 4.008790 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:08:39 Magnet Current, Imag = 400.8655 A Vtrans = 4.008640 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:08:39 Magnet Current Measurement: Imag = 400.8727 +- 0.0246 A 10:08:39 Magnetic Field Measurement Measuring the magnet strength... 10:08:39 Integrated Voltage Measurement... 10:08:53 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.004916 (Vs) 10:09:04 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.004885 (Vs) 10:09:15 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.004916 (Vs) 10:09:25 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.004884 (Vs) 10:09:36 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.004921 (Vs) 10:09:47 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.004884 (Vs) 10:09:58 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.004922 (Vs) 10:10:08 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.004887 (Vs) 10:10:08 Integrated Voltage Average and RMS of Measurements X0 = 0.000000 (m), Delta X = 0.010000 (m) VT = 0.004902 +- 0.000002 (Vs) 10:10:09 Integrated Field Strength, Average and RMS of Measurements X0 = 0.000000 (m), dx = 0.010000 (m), Nturns = 1.000000 VT = 0.004902 +- 0.000002 (Vs) BL = 0.490184 +- 0.000186 (Tm) 10:10:12 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.49018 0.00019 SL = 0.4901840 +- 0.0001863 Tm^2/m^n 10:10:12 Magnet Strength Measurement Harmonic Number = 1 SL = 0.4901840 +- 0.0001863 Tm^2/m^n 10:10:14 Magnet Current, Imag = 400.8685 A Vtrans = 4.008670 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:10:15 Magnet Current, Imag = 400.7885 A Vtrans = 4.007870 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:10:17 Magnet Current, Imag = 400.8235 A Vtrans = 4.008220 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:10:18 Magnet Current, Imag = 400.8325 A Vtrans = 4.008310 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:10:18 Magnet Current Measurement: Imag = 400.8282 +- 0.0285 A 10:10:18 Magnet current ramping to 500.0000 A... 10:11:20 Magnet Current, Imag = 501.1465 A Vtrans = 5.011450 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:11:21 Magnet Current, Imag = 501.1265 A Vtrans = 5.011250 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:11:23 Magnet Current, Imag = 501.0505 A Vtrans = 5.010490 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:11:24 Magnet Current, Imag = 501.1175 A Vtrans = 5.011160 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:11:24 Magnet Current Measurement: Imag = 501.1102 +- 0.0361 A 10:11:24 Magnetic Field Measurement Measuring the magnet strength... 10:11:25 Integrated Voltage Measurement... 10:11:38 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.006137 (Vs) 10:11:49 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.006113 (Vs) 10:12:00 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.006144 (Vs) 10:12:11 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.006111 (Vs) 10:12:21 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.006149 (Vs) 10:12:32 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.006104 (Vs) 10:12:43 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.006146 (Vs) 10:12:54 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.006108 (Vs) 10:12:54 Integrated Voltage Average and RMS of Measurements X0 = 0.000000 (m), Delta X = 0.010000 (m) VT = 0.006126 +- 0.000001 (Vs) 10:12:54 Integrated Field Strength, Average and RMS of Measurements X0 = 0.000000 (m), dx = 0.010000 (m), Nturns = 1.000000 VT = 0.006126 +- 0.000001 (Vs) BL = 0.612638 +- 0.000096 (Tm) 10:12:58 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.61264 0.00010 SL = 0.6126380 +- 0.0000965 Tm^2/m^n 10:12:58 Magnet Strength Measurement Harmonic Number = 1 SL = 0.6126380 +- 0.0000965 Tm^2/m^n 10:12:59 Magnet Current, Imag = 501.1075 A Vtrans = 5.011060 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:13:00 Magnet Current, Imag = 501.0825 A Vtrans = 5.010810 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:13:02 Magnet Current, Imag = 501.1095 A Vtrans = 5.011080 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:13:03 Magnet Current, Imag = 501.1185 A Vtrans = 5.011170 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:13:03 Magnet Current Measurement: Imag = 501.1045 +- 0.0134 A 10:13:04 Magnet current ramping to 600.0000 A... 10:14:05 Magnet Current, Imag = 601.5165 A Vtrans = 6.015150 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:14:06 Magnet Current, Imag = 601.5635 A Vtrans = 6.015620 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:14:08 Magnet Current, Imag = 601.5265 A Vtrans = 6.015250 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:14:09 Magnet Current, Imag = 601.5405 A Vtrans = 6.015390 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:14:09 Magnet Current Measurement: Imag = 601.5367 +- 0.0176 A 10:14:10 Magnetic Field Measurement Measuring the magnet strength... 10:14:10 Integrated Voltage Measurement... 10:14:23 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.007352 (Vs) 10:14:34 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.007322 (Vs) 10:14:45 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.007363 (Vs) 10:14:56 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.007324 (Vs) 10:15:06 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.007351 (Vs) 10:15:17 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.007323 (Vs) 10:15:28 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.007370 (Vs) 10:15:39 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.007324 (Vs) 10:15:39 Integrated Voltage Average and RMS of Measurements X0 = 0.000000 (m), Delta X = 0.010000 (m) VT = 0.007341 +- 0.000004 (Vs) 10:15:39 Integrated Field Strength, Average and RMS of Measurements X0 = 0.000000 (m), dx = 0.010000 (m), Nturns = 1.000000 VT = 0.007341 +- 0.000004 (Vs) BL = 0.734130 +- 0.000424 (Tm) 10:15:43 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.73413 0.00042 SL = 0.7341295 +- 0.0004243 Tm^2/m^n 10:15:43 Magnet Strength Measurement Harmonic Number = 1 SL = 0.7341295 +- 0.0004243 Tm^2/m^n 10:15:44 Magnet Current, Imag = 601.4625 A Vtrans = 6.014610 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:15:46 Magnet Current, Imag = 601.5305 A Vtrans = 6.015290 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:15:47 Magnet Current, Imag = 601.5305 A Vtrans = 6.015290 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:15:49 Magnet Current, Imag = 601.5185 A Vtrans = 6.015170 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:15:49 Magnet Current Measurement: Imag = 601.5105 +- 0.0281 A 10:15:49 Magnet current ramping to 700.0000 A... 10:16:50 Magnet Current, Imag = 700.4935 A Vtrans = 7.004920 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:16:52 Magnet Current, Imag = 700.5345 A Vtrans = 7.005330 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:16:53 Magnet Current, Imag = 700.5165 A Vtrans = 7.005150 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:16:55 Magnet Current, Imag = 700.5185 A Vtrans = 7.005170 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:16:55 Magnet Current Measurement: Imag = 700.5157 +- 0.0146 A 10:16:55 Magnetic Field Measurement Measuring the magnet strength... 10:16:55 Integrated Voltage Measurement... 10:17:09 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.008537 (Vs) 10:17:19 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.008519 (Vs) 10:17:30 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.008546 (Vs) 10:17:41 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.008513 (Vs) 10:17:52 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.008549 (Vs) 10:18:02 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.008519 (Vs) 10:18:13 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.008544 (Vs) 10:18:24 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.008508 (Vs) 10:18:24 Integrated Voltage Average and RMS of Measurements X0 = 0.000000 (m), Delta X = 0.010000 (m) VT = 0.008529 +- 0.000003 (Vs) 10:18:24 Integrated Field Strength, Average and RMS of Measurements X0 = 0.000000 (m), dx = 0.010000 (m), Nturns = 1.000000 VT = 0.008529 +- 0.000003 (Vs) BL = 0.852937 +- 0.000297 (Tm) 10:18:28 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.85294 0.00030 SL = 0.8529371 +- 0.0002974 Tm^2/m^n 10:18:28 Magnet Strength Measurement Harmonic Number = 1 SL = 0.8529371 +- 0.0002974 Tm^2/m^n 10:18:29 Magnet Current, Imag = 700.4705 A Vtrans = 7.004690 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:18:31 Magnet Current, Imag = 700.5265 A Vtrans = 7.005250 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:18:32 Magnet Current, Imag = 700.5065 A Vtrans = 7.005050 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:18:34 Magnet Current, Imag = 700.4705 A Vtrans = 7.004690 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:18:34 Magnet Current Measurement: Imag = 700.4935 +- 0.0241 A 10:18:34 Magnet current ramping to 800.0000 A... 10:19:35 Magnet Current, Imag = 801.0395 A Vtrans = 8.010380 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:19:37 Magnet Current, Imag = 801.0215 A Vtrans = 8.010200 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:19:38 Magnet Current, Imag = 800.9575 A Vtrans = 8.009560 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:19:40 Magnet Current, Imag = 800.9315 A Vtrans = 8.009300 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:19:40 Magnet Current Measurement: Imag = 800.9875 +- 0.0444 A 10:19:40 Magnetic Field Measurement Measuring the magnet strength... 10:19:40 Integrated Voltage Measurement... 10:19:54 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.009719 (Vs) 10:20:04 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.009698 (Vs) 10:20:15 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.009714 (Vs) 10:20:26 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.009714 (Vs) 10:20:37 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.009717 (Vs) 10:20:47 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.009703 (Vs) 10:20:58 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.009724 (Vs) 10:21:09 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.009683 (Vs) 10:21:09 Integrated Voltage Average and RMS of Measurements X0 = 0.000000 (m), Delta X = 0.010000 (m) VT = 0.009709 +- 0.000004 (Vs) 10:21:09 Integrated Field Strength, Average and RMS of Measurements X0 = 0.000000 (m), dx = 0.010000 (m), Nturns = 1.000000 VT = 0.009709 +- 0.000004 (Vs) BL = 0.970894 +- 0.000369 (Tm) 10:21:13 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.97089 0.00037 SL = 0.9708940 +- 0.0003688 Tm^2/m^n 10:21:13 Magnet Strength Measurement Harmonic Number = 1 SL = 0.9708940 +- 0.0003688 Tm^2/m^n 10:21:14 Magnet Current, Imag = 800.9325 A Vtrans = 8.009310 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:21:16 Magnet Current, Imag = 800.9195 A Vtrans = 8.009180 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:21:17 Magnet Current, Imag = 800.9885 A Vtrans = 8.009870 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:21:18 Magnet Current, Imag = 801.0775 A Vtrans = 8.010760 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:21:18 Magnet Current Measurement: Imag = 800.9795 +- 0.0622 A 10:21:19 Magnet current ramping to 900.0000 A... 10:22:20 Magnet Current, Imag = 901.1845 A Vtrans = 9.011830 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:22:22 Magnet Current, Imag = 901.0995 A Vtrans = 9.010980 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:22:23 Magnet Current, Imag = 901.0505 A Vtrans = 9.010490 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:22:25 Magnet Current, Imag = 901.2345 A Vtrans = 9.012330 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:22:25 Magnet Current Measurement: Imag = 901.1422 +- 0.0717 A 10:22:25 Magnetic Field Measurement Measuring the magnet strength... 10:22:25 Integrated Voltage Measurement... 10:22:39 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.010826 (Vs) 10:22:49 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.010799 (Vs) 10:23:00 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.010831 (Vs) 10:23:11 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.010792 (Vs) 10:23:22 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.010837 (Vs) 10:23:33 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.010789 (Vs) 10:23:43 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.010841 (Vs) 10:23:54 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.010805 (Vs) 10:23:54 Integrated Voltage Average and RMS of Measurements X0 = 0.000000 (m), Delta X = 0.010000 (m) VT = 0.010815 +- 0.000005 (Vs) 10:23:54 Integrated Field Strength, Average and RMS of Measurements X0 = 0.000000 (m), dx = 0.010000 (m), Nturns = 1.000000 VT = 0.010815 +- 0.000005 (Vs) BL = 1.081479 +- 0.000457 (Tm) 10:23:58 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.08148 0.00046 SL = 1.0814788 +- 0.0004574 Tm^2/m^n 10:23:58 Magnet Strength Measurement Harmonic Number = 1 SL = 1.0814788 +- 0.0004574 Tm^2/m^n 10:23:59 Magnet Current, Imag = 901.2235 A Vtrans = 9.012220 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:24:01 Magnet Current, Imag = 901.1765 A Vtrans = 9.011750 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:24:02 Magnet Current, Imag = 901.1195 A Vtrans = 9.011180 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:24:04 Magnet Current, Imag = 901.1385 A Vtrans = 9.011370 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:24:04 Magnet Current Measurement: Imag = 901.1645 +- 0.0398 A 10:24:04 Magnet current ramping to 850.0000 A... 10:24:51 Magnet Current, Imag = 850.8845 A Vtrans = 8.508830 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:24:53 Magnet Current, Imag = 850.9585 A Vtrans = 8.509570 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:24:54 Magnet Current, Imag = 850.9985 A Vtrans = 8.509970 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:24:55 Magnet Current, Imag = 850.9205 A Vtrans = 8.509190 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:24:56 Magnet Current Measurement: Imag = 850.9405 +- 0.0425 A 10:24:56 Magnetic Field Measurement Measuring the magnet strength... 10:24:56 Integrated Voltage Measurement... 10:25:09 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.010341 (Vs) 10:25:20 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.010309 (Vs) 10:25:31 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.010325 (Vs) 10:25:42 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.010302 (Vs) 10:25:53 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.010357 (Vs) 10:26:04 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.010310 (Vs) 10:26:14 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.010351 (Vs) 10:26:25 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.010313 (Vs) 10:26:25 Integrated Voltage Average and RMS of Measurements X0 = 0.000000 (m), Delta X = 0.010000 (m) VT = 0.010326 +- 0.000008 (Vs) 10:26:25 Integrated Field Strength, Average and RMS of Measurements X0 = 0.000000 (m), dx = 0.010000 (m), Nturns = 1.000000 VT = 0.010326 +- 0.000008 (Vs) BL = 1.032603 +- 0.000781 (Tm) 10:26:29 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.03260 0.00078 SL = 1.0326031 +- 0.0007810 Tm^2/m^n 10:26:29 Magnet Strength Measurement Harmonic Number = 1 SL = 1.0326031 +- 0.0007810 Tm^2/m^n 10:26:30 Magnet Current, Imag = 850.8915 A Vtrans = 8.508900 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:26:32 Magnet Current, Imag = 850.9525 A Vtrans = 8.509510 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:26:33 Magnet Current, Imag = 850.9355 A Vtrans = 8.509340 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:26:35 Magnet Current, Imag = 850.9275 A Vtrans = 8.509260 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:26:35 Magnet Current Measurement: Imag = 850.9267 +- 0.0223 A 10:26:35 Magnet current ramping to 800.0000 A... 10:27:22 Magnet Current, Imag = 800.9235 A Vtrans = 8.009220 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:27:24 Magnet Current, Imag = 800.8575 A Vtrans = 8.008560 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:27:25 Magnet Current, Imag = 800.9155 A Vtrans = 8.009140 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:27:27 Magnet Current, Imag = 800.9425 A Vtrans = 8.009410 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:27:27 Magnet Current Measurement: Imag = 800.9097 +- 0.0317 A 10:27:27 Magnetic Field Measurement Measuring the magnet strength... 10:27:27 Integrated Voltage Measurement... 10:27:40 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.009792 (Vs) 10:27:51 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.009751 (Vs) 10:28:02 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.009800 (Vs) 10:28:13 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.009762 (Vs) 10:28:24 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.009791 (Vs) 10:28:34 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.009767 (Vs) 10:28:45 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.009774 (Vs) 10:28:56 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.009756 (Vs) 10:28:56 Integrated Voltage Average and RMS of Measurements X0 = 0.000000 (m), Delta X = 0.010000 (m) VT = 0.009774 +- 0.000006 (Vs) 10:28:56 Integrated Field Strength, Average and RMS of Measurements X0 = 0.000000 (m), dx = 0.010000 (m), Nturns = 1.000000 VT = 0.009774 +- 0.000006 (Vs) BL = 0.977426 +- 0.000623 (Tm) 10:29:00 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.97743 0.00062 SL = 0.9774259 +- 0.0006227 Tm^2/m^n 10:29:00 Magnet Strength Measurement Harmonic Number = 1 SL = 0.9774259 +- 0.0006227 Tm^2/m^n 10:29:01 Magnet Current, Imag = 800.9105 A Vtrans = 8.009090 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:29:03 Magnet Current, Imag = 800.9105 A Vtrans = 8.009090 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:29:04 Magnet Current, Imag = 800.9345 A Vtrans = 8.009330 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:29:06 Magnet Current, Imag = 800.9525 A Vtrans = 8.009510 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:29:06 Magnet Current Measurement: Imag = 800.9270 +- 0.0177 A 10:29:06 Magnet current ramping to 750.0000 A... 10:29:53 Magnet Current, Imag = 751.0775 A Vtrans = 7.510760 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:29:55 Magnet Current, Imag = 751.1025 A Vtrans = 7.511010 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:29:56 Magnet Current, Imag = 751.0765 A Vtrans = 7.510750 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:29:57 Magnet Current, Imag = 751.0345 A Vtrans = 7.510330 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:29:57 Magnet Current Measurement: Imag = 751.0727 +- 0.0244 A 10:29:58 Magnetic Field Measurement Measuring the magnet strength... 10:29:58 Integrated Voltage Measurement... 10:30:11 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.009220 (Vs) 10:30:22 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.009174 (Vs) 10:30:33 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.009213 (Vs) 10:30:44 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.009172 (Vs) 10:30:54 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.009223 (Vs) 10:31:05 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.009174 (Vs) 10:31:16 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.009217 (Vs) 10:31:27 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.009182 (Vs) 10:31:27 Integrated Voltage Average and RMS of Measurements X0 = 0.000000 (m), Delta X = 0.010000 (m) VT = 0.009197 +- 0.000003 (Vs) 10:31:27 Integrated Field Strength, Average and RMS of Measurements X0 = 0.000000 (m), dx = 0.010000 (m), Nturns = 1.000000 VT = 0.009197 +- 0.000003 (Vs) BL = 0.919689 +- 0.000271 (Tm) 10:31:30 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.91969 0.00027 SL = 0.9196888 +- 0.0002709 Tm^2/m^n 10:31:30 Magnet Strength Measurement Harmonic Number = 1 SL = 0.9196888 +- 0.0002709 Tm^2/m^n 10:31:32 Magnet Current, Imag = 751.1075 A Vtrans = 7.511060 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:31:33 Magnet Current, Imag = 751.0025 A Vtrans = 7.510010 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:31:35 Magnet Current, Imag = 751.0265 A Vtrans = 7.510250 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:31:36 Magnet Current, Imag = 751.0535 A Vtrans = 7.510520 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:31:36 Magnet Current Measurement: Imag = 751.0475 +- 0.0391 A 10:31:37 Magnet current ramping to 700.0000 A... 10:32:24 Magnet Current, Imag = 700.5825 A Vtrans = 7.005810 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:32:25 Magnet Current, Imag = 700.5555 A Vtrans = 7.005540 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:32:27 Magnet Current, Imag = 700.4785 A Vtrans = 7.004770 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:32:28 Magnet Current, Imag = 700.5005 A Vtrans = 7.004990 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:32:28 Magnet Current Measurement: Imag = 700.5292 +- 0.0416 A 10:32:28 Magnetic Field Measurement Measuring the magnet strength... 10:32:28 Integrated Voltage Measurement... 10:32:42 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.008615 (Vs) 10:32:53 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.008596 (Vs) 10:33:04 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.008608 (Vs) 10:33:14 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.008582 (Vs) 10:33:25 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.008621 (Vs) 10:33:36 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.008584 (Vs) 10:33:47 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.008613 (Vs) 10:33:57 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.008583 (Vs) 10:33:57 Integrated Voltage Average and RMS of Measurements X0 = 0.000000 (m), Delta X = 0.010000 (m) VT = 0.008600 +- 0.000004 (Vs) 10:33:57 Integrated Field Strength, Average and RMS of Measurements X0 = 0.000000 (m), dx = 0.010000 (m), Nturns = 1.000000 VT = 0.008600 +- 0.000004 (Vs) BL = 0.860027 +- 0.000387 (Tm) 10:34:01 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.86003 0.00039 SL = 0.8600274 +- 0.0003870 Tm^2/m^n 10:34:01 Magnet Strength Measurement Harmonic Number = 1 SL = 0.8600274 +- 0.0003870 Tm^2/m^n 10:34:03 Magnet Current, Imag = 700.4985 A Vtrans = 7.004970 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:34:04 Magnet Current, Imag = 700.5315 A Vtrans = 7.005300 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:34:05 Magnet Current, Imag = 700.5795 A Vtrans = 7.005780 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:34:07 Magnet Current, Imag = 700.5585 A Vtrans = 7.005570 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:34:07 Magnet Current Measurement: Imag = 700.5420 +- 0.0303 A 10:34:07 Magnet current ramping to 600.0000 A... 10:35:09 Magnet Current, Imag = 601.5725 A Vtrans = 6.015710 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:35:10 Magnet Current, Imag = 601.5585 A Vtrans = 6.015570 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:35:12 Magnet Current, Imag = 601.4975 A Vtrans = 6.014960 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:35:13 Magnet Current, Imag = 601.5645 A Vtrans = 6.015630 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:35:14 Magnet Current Measurement: Imag = 601.5482 +- 0.0297 A 10:35:14 Magnetic Field Measurement Measuring the magnet strength... 10:35:14 Integrated Voltage Measurement... 10:35:27 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.007427 (Vs) 10:35:38 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.007379 (Vs) 10:35:49 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.007435 (Vs) 10:36:00 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.007386 (Vs) 10:36:11 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.007418 (Vs) 10:36:21 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.007363 (Vs) 10:36:32 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.007414 (Vs) 10:36:43 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.007386 (Vs) 10:36:43 Integrated Voltage Average and RMS of Measurements X0 = 0.000000 (m), Delta X = 0.010000 (m) VT = 0.007401 +- 0.000007 (Vs) 10:36:43 Integrated Field Strength, Average and RMS of Measurements X0 = 0.000000 (m), dx = 0.010000 (m), Nturns = 1.000000 VT = 0.007401 +- 0.000007 (Vs) BL = 0.740088 +- 0.000695 (Tm) 10:36:47 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.74009 0.00069 SL = 0.7400879 +- 0.0006948 Tm^2/m^n 10:36:47 Magnet Strength Measurement Harmonic Number = 1 SL = 0.7400879 +- 0.0006948 Tm^2/m^n 10:36:48 Magnet Current, Imag = 601.6445 A Vtrans = 6.016430 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:36:50 Magnet Current, Imag = 601.6075 A Vtrans = 6.016060 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:36:51 Magnet Current, Imag = 601.6155 A Vtrans = 6.016140 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:36:53 Magnet Current, Imag = 601.5985 A Vtrans = 6.015970 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:36:53 Magnet Current Measurement: Imag = 601.6165 +- 0.0172 A 10:36:53 Magnet current ramping to 500.0000 A... 10:37:54 Magnet Current, Imag = 501.1725 A Vtrans = 5.011710 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:37:56 Magnet Current, Imag = 501.1305 A Vtrans = 5.011290 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:37:57 Magnet Current, Imag = 501.2335 A Vtrans = 5.012320 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:37:59 Magnet Current, Imag = 501.1385 A Vtrans = 5.011370 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:37:59 Magnet Current Measurement: Imag = 501.1687 +- 0.0406 A 10:37:59 Magnetic Field Measurement Measuring the magnet strength... 10:37:59 Integrated Voltage Measurement... 10:38:13 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.006199 (Vs) 10:38:24 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.006155 (Vs) 10:38:35 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.006200 (Vs) 10:38:45 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.006161 (Vs) 10:38:56 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.006201 (Vs) 10:39:07 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.006169 (Vs) 10:39:18 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.006199 (Vs) 10:39:29 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.006155 (Vs) 10:39:29 Integrated Voltage Average and RMS of Measurements X0 = 0.000000 (m), Delta X = 0.010000 (m) VT = 0.006180 +- 0.000003 (Vs) 10:39:29 Integrated Field Strength, Average and RMS of Measurements X0 = 0.000000 (m), dx = 0.010000 (m), Nturns = 1.000000 VT = 0.006180 +- 0.000003 (Vs) BL = 0.617980 +- 0.000328 (Tm) 10:39:33 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.61798 0.00033 SL = 0.6179801 +- 0.0003280 Tm^2/m^n 10:39:33 Magnet Strength Measurement Harmonic Number = 1 SL = 0.6179801 +- 0.0003280 Tm^2/m^n 10:39:34 Magnet Current, Imag = 501.0775 A Vtrans = 5.010760 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:39:36 Magnet Current, Imag = 501.1305 A Vtrans = 5.011290 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:39:37 Magnet Current, Imag = 501.1565 A Vtrans = 5.011550 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:39:39 Magnet Current, Imag = 501.1425 A Vtrans = 5.011410 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:39:39 Magnet Current Measurement: Imag = 501.1267 +- 0.0299 A 10:39:39 Magnet current ramping to 400.0000 A... 10:40:40 Magnet Current, Imag = 400.9175 A Vtrans = 4.009160 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:40:42 Magnet Current, Imag = 400.8485 A Vtrans = 4.008470 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:40:43 Magnet Current, Imag = 400.8365 A Vtrans = 4.008350 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:40:45 Magnet Current, Imag = 400.8655 A Vtrans = 4.008640 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:40:45 Magnet Current Measurement: Imag = 400.8670 +- 0.0309 A 10:40:45 Magnetic Field Measurement Measuring the magnet strength... 10:40:45 Integrated Voltage Measurement... 10:40:59 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.004959 (Vs) 10:41:10 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.004924 (Vs) 10:41:20 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.004968 (Vs) 10:41:31 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.004922 (Vs) 10:41:42 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.004956 (Vs) 10:41:53 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.004921 (Vs) 10:42:03 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.004974 (Vs) 10:42:14 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.004939 (Vs) 10:42:14 Integrated Voltage Average and RMS of Measurements X0 = 0.000000 (m), Delta X = 0.010000 (m) VT = 0.004945 +- 0.000007 (Vs) 10:42:15 Integrated Field Strength, Average and RMS of Measurements X0 = 0.000000 (m), dx = 0.010000 (m), Nturns = 1.000000 VT = 0.004945 +- 0.000007 (Vs) BL = 0.494540 +- 0.000675 (Tm) 10:42:18 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.49454 0.00068 SL = 0.4945402 +- 0.0006752 Tm^2/m^n 10:42:18 Magnet Strength Measurement Harmonic Number = 1 SL = 0.4945402 +- 0.0006752 Tm^2/m^n 10:42:20 Magnet Current, Imag = 400.8735 A Vtrans = 4.008720 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:42:21 Magnet Current, Imag = 400.9235 A Vtrans = 4.009220 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:42:23 Magnet Current, Imag = 400.8935 A Vtrans = 4.008920 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:42:24 Magnet Current, Imag = 400.8845 A Vtrans = 4.008830 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:42:24 Magnet Current Measurement: Imag = 400.8937 +- 0.0186 A 10:42:25 Magnet current ramping to 300.0000 A... 10:43:26 Magnet Current, Imag = 300.8006 A Vtrans = 3.007991 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:43:27 Magnet Current, Imag = 300.8644 A Vtrans = 3.008629 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:43:29 Magnet Current, Imag = 300.8924 A Vtrans = 3.008909 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:43:30 Magnet Current, Imag = 300.7886 A Vtrans = 3.007871 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:43:30 Magnet Current Measurement: Imag = 300.8365 +- 0.0433 A 10:43:30 Magnetic Field Measurement Measuring the magnet strength... 10:43:30 Integrated Voltage Measurement... 10:43:44 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.003738 (Vs) 10:43:54 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.003700 (Vs) 10:44:05 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.003734 (Vs) 10:44:16 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.003708 (Vs) 10:44:27 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.003743 (Vs) 10:44:37 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.003710 (Vs) 10:44:48 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.003729 (Vs) 10:44:59 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.003712 (Vs) 10:44:59 Integrated Voltage Average and RMS of Measurements X0 = 0.000000 (m), Delta X = 0.010000 (m) VT = 0.003722 +- 0.000003 (Vs) 10:44:59 Integrated Field Strength, Average and RMS of Measurements X0 = 0.000000 (m), dx = 0.010000 (m), Nturns = 1.000000 VT = 0.003722 +- 0.000003 (Vs) BL = 0.372173 +- 0.000259 (Tm) 10:45:03 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.37217 0.00026 SL = 0.3721726 +- 0.0002590 Tm^2/m^n 10:45:03 Magnet Strength Measurement Harmonic Number = 1 SL = 0.3721726 +- 0.0002590 Tm^2/m^n 10:45:04 Magnet Current, Imag = 300.7902 A Vtrans = 3.007887 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:45:05 Magnet Current, Imag = 300.8303 A Vtrans = 3.008288 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:45:07 Magnet Current, Imag = 300.8707 A Vtrans = 3.008692 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:45:08 Magnet Current, Imag = 300.8887 A Vtrans = 3.008872 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:45:08 Magnet Current Measurement: Imag = 300.8449 +- 0.0380 A 10:45:08 Magnet current ramping to 200.0000 A... 10:46:10 Magnet Current, Imag = 200.0564 A Vtrans = 2.000549 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:46:11 Magnet Current, Imag = 200.0915 A Vtrans = 2.000900 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:46:12 Magnet Current, Imag = 200.1610 A Vtrans = 2.001595 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:46:14 Magnet Current, Imag = 200.0833 A Vtrans = 2.000818 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:46:14 Magnet Current Measurement: Imag = 200.0980 +- 0.0386 A 10:46:14 Magnetic Field Measurement Measuring the magnet strength... 10:46:14 Integrated Voltage Measurement... 10:46:28 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.002511 (Vs) 10:46:39 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.002475 (Vs) 10:46:49 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.002500 (Vs) 10:47:00 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.002467 (Vs) 10:47:11 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.002506 (Vs) 10:47:22 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.002488 (Vs) 10:47:32 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.002510 (Vs) 10:47:43 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.002469 (Vs) 10:47:43 Integrated Voltage Average and RMS of Measurements X0 = 0.000000 (m), Delta X = 0.010000 (m) VT = 0.002491 +- 0.000005 (Vs) 10:47:43 Integrated Field Strength, Average and RMS of Measurements X0 = 0.000000 (m), dx = 0.010000 (m), Nturns = 1.000000 VT = 0.002491 +- 0.000005 (Vs) BL = 0.249074 +- 0.000498 (Tm) 10:47:47 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.24907 0.00050 SL = 0.2490736 +- 0.0004976 Tm^2/m^n 10:47:47 Magnet Strength Measurement Harmonic Number = 1 SL = 0.2490736 +- 0.0004976 Tm^2/m^n 10:47:48 Magnet Current, Imag = 200.1679 A Vtrans = 2.001664 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:47:49 Magnet Current, Imag = 200.1297 A Vtrans = 2.001282 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:47:51 Magnet Current, Imag = 200.0723 A Vtrans = 2.000708 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:47:52 Magnet Current, Imag = 200.0767 A Vtrans = 2.000752 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:47:52 Magnet Current Measurement: Imag = 200.1116 +- 0.0396 A 10:47:52 Magnet current ramping to 100.0000 A... 10:48:54 Magnet Current, Imag = 100.0732 A Vtrans = 1.000717 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:48:55 Magnet Current, Imag = 100.1420 A Vtrans = 1.001405 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:48:56 Magnet Current, Imag = 100.1259 A Vtrans = 1.001244 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:48:58 Magnet Current, Imag = 100.0525 A Vtrans = 1.000510 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:48:58 Magnet Current Measurement: Imag = 100.0984 +- 0.0367 A 10:48:58 Magnetic Field Measurement Measuring the magnet strength... 10:48:58 Integrated Voltage Measurement... 10:49:12 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.001278 (Vs) 10:49:23 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.001236 (Vs) 10:49:33 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.001277 (Vs) 10:49:44 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.001250 (Vs) 10:49:55 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.001280 (Vs) 10:50:06 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.001243 (Vs) 10:50:16 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = 0.010000 (m), VT = 0.001280 (Vs) 10:50:27 Integrated Voltage Measurement X0 = 0.000000 (m), Delta X = -0.010000 (m), VT = -0.001245 (Vs) 10:50:27 Integrated Voltage Average and RMS of Measurements X0 = 0.000000 (m), Delta X = 0.010000 (m) VT = 0.001261 +- 0.000003 (Vs) 10:50:27 Integrated Field Strength, Average and RMS of Measurements X0 = 0.000000 (m), dx = 0.010000 (m), Nturns = 1.000000 VT = 0.001261 +- 0.000003 (Vs) BL = 0.126117 +- 0.000253 (Tm) 10:50:31 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.12612 0.00025 SL = 0.1261170 +- 0.0002529 Tm^2/m^n 10:50:31 Magnet Strength Measurement Harmonic Number = 1 SL = 0.1261170 +- 0.0002529 Tm^2/m^n 10:50:32 Magnet Current, Imag = 100.0559 A Vtrans = 1.000544 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:50:34 Magnet Current, Imag = 100.1027 A Vtrans = 1.001012 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:50:35 Magnet Current, Imag = 100.0474 A Vtrans = 1.000459 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:50:36 Magnet Current, Imag = 100.1340 A Vtrans = 1.001325 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001463 A 10:50:36 Magnet Current Measurement: Imag = 100.0850 +- 0.0353 A 10:50:37 Magnet current ramping to 0.0000 A...