SLAC Magnetic Measurements Date: 08-06-2001 Time: 13:39:46 Project: spear3 Magnet Type: gdipole Magnet Name: 145d-019 Serial Number: Run Number: 6 Measurement Device: stretched wire Operator: jy Comment: BL vs. I, mains Standardization: 1 cycles from 0.0 A to 770.0 A to 0.0 A Test Currents (A): 50.0 100.0 150.0 200.0 250.0 300.0 350.0 400.0 450.0 500.0 525.0 550.0 575.0 600.0 625.0 650.0 675.0 700.0 650.0 600.0 550.0 500.0 450.0 400.0 13:39:54 Initial Zero Current Measurement, Imag_zero = 0.0000 A 13:39:54 Magnet current ramping to 15.0000 A... 13:40:26 Magnet current ramping to 770.0000 A... 13:44:40 Magnet current ramping to 0.0000 A... 13:49:28 Magnet current ramping to 50.0000 A... 13:49:51 Magnet Current, Imag = 61.9709 A Vtrans = 0.619709 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:49:52 Magnet Current, Imag = 46.7432 A Vtrans = 0.467432 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:49:54 Magnet Current, Imag = 47.6921 A Vtrans = 0.476921 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:49:55 Magnet Current, Imag = 51.5911 A Vtrans = 0.515911 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:49:55 Magnet Current Measurement: Imag = 51.9993 +- 6.0369 A 13:49:56 Magnetic Field Measurement Measuring the magnet strength... 13:49:56 Integrated Voltage Measurement... 13:50:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001509317 Vs 13:50:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001802671 Vs 13:50:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001409763 Vs 13:50:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001796055 Vs 13:50:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001406633 Vs 13:51:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001800863 Vs 13:51:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001412478 Vs 13:51:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001809067 Vs 13:51:24 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001618356 +- 0.000021944 Vs 13:51:24 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.001618356 +- 0.000021944 Vs BL = 0.16183558 +- 0.00219441 Tm 13:51:27 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.16184 0.00219 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.16184 0.00219 0.16184 0.00000 13:51:27 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.16184 0.00219 SL = 0.1618356 +- 0.0021944 Tm^2/m^n 13:51:28 Magnet Strength Measurement Harmonic Number = 1 SL = 0.1618356 +- 0.0021944 Tm^2/m^n 13:51:29 Magnet Current, Imag = 49.8431 A Vtrans = 0.498431 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:51:31 Magnet Current, Imag = 49.8338 A Vtrans = 0.498338 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:51:32 Magnet Current, Imag = 49.8374 A Vtrans = 0.498374 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:51:34 Magnet Current, Imag = 49.8321 A Vtrans = 0.498321 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:51:34 Magnet Current Measurement: Imag = 49.8366 +- 0.0042 A 13:51:34 Magnet current ramping to 100.0000 A... 13:51:57 Magnet Current, Imag = 99.8627 A Vtrans = 0.998627 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:51:58 Magnet Current, Imag = 99.8601 A Vtrans = 0.998601 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:52:00 Magnet Current, Imag = 99.8678 A Vtrans = 0.998678 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:52:01 Magnet Current, Imag = 99.8630 A Vtrans = 0.998630 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:52:01 Magnet Current Measurement: Imag = 99.8634 +- 0.0028 A 13:52:01 Magnetic Field Measurement Measuring the magnet strength... 13:52:01 Integrated Voltage Measurement... 13:52:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002974925 Vs 13:52:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003374646 Vs 13:52:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002979297 Vs 13:52:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003373945 Vs 13:52:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002982703 Vs 13:53:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003376162 Vs 13:53:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002978025 Vs 13:53:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003364937 Vs 13:53:30 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003175580 +- 0.000002888 Vs 13:53:30 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.003175580 +- 0.000002888 Vs BL = 0.31755801 +- 0.00028880 Tm 13:53:33 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.31756 0.00029 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.31756 0.00029 0.31756 0.00000 13:53:33 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.31756 0.00029 SL = 0.3175580 +- 0.0002888 Tm^2/m^n 13:53:33 Magnet Strength Measurement Harmonic Number = 1 SL = 0.3175580 +- 0.0002888 Tm^2/m^n 13:53:35 Magnet Current, Imag = 99.8720 A Vtrans = 0.998720 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:53:36 Magnet Current, Imag = 99.8897 A Vtrans = 0.998897 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:53:38 Magnet Current, Imag = 99.8689 A Vtrans = 0.998689 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:53:39 Magnet Current, Imag = 99.8527 A Vtrans = 0.998527 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:53:39 Magnet Current Measurement: Imag = 99.8708 +- 0.0131 A 13:53:40 Magnet current ramping to 150.0000 A... 13:54:02 Magnet Current, Imag = 149.8805 A Vtrans = 1.498805 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:54:04 Magnet Current, Imag = 149.8992 A Vtrans = 1.498992 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:54:05 Magnet Current, Imag = 149.8965 A Vtrans = 1.498965 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:54:07 Magnet Current, Imag = 149.8935 A Vtrans = 1.498935 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:54:07 Magnet Current Measurement: Imag = 149.8924 +- 0.0072 A 13:54:07 Magnetic Field Measurement Measuring the magnet strength... 13:54:07 Integrated Voltage Measurement... 13:54:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004564436 Vs 13:54:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004966063 Vs 13:54:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004575376 Vs 13:54:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004970069 Vs 13:55:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004575268 Vs 13:55:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004960465 Vs 13:55:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004575950 Vs 13:55:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004973450 Vs 13:55:35 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004770135 +- 0.000003760 Vs 13:55:36 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.004770135 +- 0.000003760 Vs BL = 0.47701347 +- 0.00037600 Tm 13:55:39 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.47701 0.00038 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.47701 0.00038 0.47701 0.00000 13:55:39 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.47701 0.00038 SL = 0.4770135 +- 0.0003760 Tm^2/m^n 13:55:39 Magnet Strength Measurement Harmonic Number = 1 SL = 0.4770135 +- 0.0003760 Tm^2/m^n 13:55:40 Magnet Current, Imag = 149.8941 A Vtrans = 1.498941 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:55:42 Magnet Current, Imag = 149.9021 A Vtrans = 1.499021 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:55:43 Magnet Current, Imag = 149.8871 A Vtrans = 1.498871 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:55:45 Magnet Current, Imag = 149.8802 A Vtrans = 1.498802 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:55:45 Magnet Current Measurement: Imag = 149.8909 +- 0.0081 A 13:55:45 Magnet current ramping to 200.0000 A... 13:56:08 Magnet Current, Imag = 199.8970 A Vtrans = 1.998970 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:56:09 Magnet Current, Imag = 199.8999 A Vtrans = 1.998999 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:56:11 Magnet Current, Imag = 199.8844 A Vtrans = 1.998844 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:56:12 Magnet Current, Imag = 199.8801 A Vtrans = 1.998801 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:56:13 Magnet Current Measurement: Imag = 199.8903 +- 0.0083 A 13:56:13 Magnetic Field Measurement Measuring the magnet strength... 13:56:13 Integrated Voltage Measurement... 13:56:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006168575 Vs 13:56:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006559586 Vs 13:56:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006181445 Vs 13:56:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006565186 Vs 13:57:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006168316 Vs 13:57:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006567587 Vs 13:57:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006166132 Vs 13:57:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006564361 Vs 13:57:41 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006367649 +- 0.000003561 Vs 13:57:42 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.006367649 +- 0.000003561 Vs BL = 0.63676486 +- 0.00035605 Tm 13:57:45 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.63676 0.00036 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.63676 0.00036 0.63676 0.00000 13:57:45 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.63676 0.00036 SL = 0.6367649 +- 0.0003561 Tm^2/m^n 13:57:45 Magnet Strength Measurement Harmonic Number = 1 SL = 0.6367649 +- 0.0003561 Tm^2/m^n 13:57:46 Magnet Current, Imag = 199.8897 A Vtrans = 1.998897 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:57:48 Magnet Current, Imag = 199.8921 A Vtrans = 1.998921 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:57:49 Magnet Current, Imag = 199.8882 A Vtrans = 1.998882 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:57:51 Magnet Current, Imag = 199.8916 A Vtrans = 1.998916 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:57:51 Magnet Current Measurement: Imag = 199.8904 +- 0.0016 A 13:57:51 Magnet current ramping to 250.0000 A... 13:58:14 Magnet Current, Imag = 249.9439 A Vtrans = 2.499439 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:58:15 Magnet Current, Imag = 249.9404 A Vtrans = 2.499404 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:58:17 Magnet Current, Imag = 249.9457 A Vtrans = 2.499457 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:58:18 Magnet Current, Imag = 249.9352 A Vtrans = 2.499352 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:58:18 Magnet Current Measurement: Imag = 249.9413 +- 0.0040 A 13:58:19 Magnetic Field Measurement Measuring the magnet strength... 13:58:19 Integrated Voltage Measurement... 13:58:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007750981 Vs 13:58:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008151844 Vs 13:58:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007757501 Vs 13:59:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008154405 Vs 13:59:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007765131 Vs 13:59:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008163044 Vs 13:59:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007762235 Vs 13:59:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008163597 Vs 13:59:47 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007958592 +- 0.000005182 Vs 13:59:47 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.007958592 +- 0.000005182 Vs BL = 0.79585923 +- 0.00051819 Tm 13:59:50 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.79586 0.00052 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.79586 0.00052 0.79586 0.00000 13:59:50 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.79586 0.00052 SL = 0.7958592 +- 0.0005182 Tm^2/m^n 13:59:50 Magnet Strength Measurement Harmonic Number = 1 SL = 0.7958592 +- 0.0005182 Tm^2/m^n 13:59:52 Magnet Current, Imag = 249.9268 A Vtrans = 2.499268 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:59:53 Magnet Current, Imag = 249.9323 A Vtrans = 2.499323 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:59:55 Magnet Current, Imag = 249.9248 A Vtrans = 2.499248 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:59:56 Magnet Current, Imag = 249.9074 A Vtrans = 2.499074 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:59:57 Magnet Current Measurement: Imag = 249.9228 +- 0.0093 A 13:59:57 Magnet current ramping to 300.0000 A... 14:00:20 Magnet Current, Imag = 299.9289 A Vtrans = 2.999289 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:00:21 Magnet Current, Imag = 299.9481 A Vtrans = 2.999481 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:00:23 Magnet Current, Imag = 299.9727 A Vtrans = 2.999727 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:00:24 Magnet Current, Imag = 299.9650 A Vtrans = 2.999650 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:00:24 Magnet Current Measurement: Imag = 299.9537 +- 0.0168 A 14:00:24 Magnetic Field Measurement Measuring the magnet strength... 14:00:24 Integrated Voltage Measurement... 14:00:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009331133 Vs 14:00:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009739942 Vs 14:00:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009349635 Vs 14:01:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009759255 Vs 14:01:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009356359 Vs 14:01:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009753586 Vs 14:01:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009345712 Vs 14:01:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009756822 Vs 14:01:53 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009549056 +- 0.000007932 Vs 14:01:53 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.009549056 +- 0.000007932 Vs BL = 0.95490556 +- 0.00079322 Tm 14:01:56 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.95491 0.00079 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.95491 0.00079 0.95491 0.00000 14:01:56 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.95491 0.00079 SL = 0.9549056 +- 0.0007932 Tm^2/m^n 14:01:56 Magnet Strength Measurement Harmonic Number = 1 SL = 0.9549056 +- 0.0007932 Tm^2/m^n 14:01:58 Magnet Current, Imag = 299.9432 A Vtrans = 2.999432 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:01:59 Magnet Current, Imag = 299.9417 A Vtrans = 2.999417 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:02:01 Magnet Current, Imag = 299.9530 A Vtrans = 2.999530 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:02:02 Magnet Current, Imag = 299.9706 A Vtrans = 2.999706 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:02:02 Magnet Current Measurement: Imag = 299.9521 +- 0.0115 A 14:02:02 Magnet current ramping to 350.0000 A... 14:02:26 Magnet Current, Imag = 350.0130 A Vtrans = 3.500130 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:02:28 Magnet Current, Imag = 350.0080 A Vtrans = 3.500080 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:02:30 Magnet Current, Imag = 350.0090 A Vtrans = 3.500090 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:02:32 Magnet Current, Imag = 349.9990 A Vtrans = 3.499990 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:02:32 Magnet Current Measurement: Imag = 350.0072 +- 0.0051 A 14:02:32 Magnetic Field Measurement Measuring the magnet strength... 14:02:32 Integrated Voltage Measurement... 14:02:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010965434 Vs 14:02:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011340589 Vs 14:03:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010951480 Vs 14:03:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011334429 Vs 14:03:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010944857 Vs 14:03:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011333574 Vs 14:03:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010937628 Vs 14:04:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011332314 Vs 14:04:00 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011142538 +- 0.000006674 Vs 14:04:00 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.011142538 +- 0.000006674 Vs BL = 1.11425381 +- 0.00066739 Tm 14:04:04 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.11425 0.00067 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.11425 0.00067 1.11425 0.00000 14:04:04 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.11425 0.00067 SL = 1.1142538 +- 0.0006674 Tm^2/m^n 14:04:04 Magnet Strength Measurement Harmonic Number = 1 SL = 1.1142538 +- 0.0006674 Tm^2/m^n 14:04:06 Magnet Current, Imag = 349.9980 A Vtrans = 3.499980 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:04:08 Magnet Current, Imag = 349.9890 A Vtrans = 3.499890 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:04:10 Magnet Current, Imag = 349.9850 A Vtrans = 3.499850 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:04:12 Magnet Current, Imag = 349.9970 A Vtrans = 3.499970 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:04:12 Magnet Current Measurement: Imag = 349.9923 +- 0.0054 A 14:04:12 Magnet current ramping to 400.0000 A... 14:04:35 Magnet Current, Imag = 399.9940 A Vtrans = 3.999940 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:04:37 Magnet Current, Imag = 399.9910 A Vtrans = 3.999910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:04:39 Magnet Current, Imag = 399.9940 A Vtrans = 3.999940 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:04:40 Magnet Current, Imag = 400.0060 A Vtrans = 4.000060 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:04:40 Magnet Current Measurement: Imag = 399.9962 +- 0.0058 A 14:04:40 Magnetic Field Measurement Measuring the magnet strength... 14:04:41 Integrated Voltage Measurement... 14:04:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012541627 Vs 14:05:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012943540 Vs 14:05:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012557293 Vs 14:05:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012939145 Vs 14:05:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012548100 Vs 14:05:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012938062 Vs 14:05:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012535295 Vs 14:06:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012931480 Vs 14:06:09 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012741818 +- 0.000005344 Vs 14:06:09 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.012741818 +- 0.000005344 Vs BL = 1.27418177 +- 0.00053438 Tm 14:06:12 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.27418 0.00053 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.27418 0.00053 1.27418 0.00000 14:06:12 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.27418 0.00053 SL = 1.2741818 +- 0.0005344 Tm^2/m^n 14:06:13 Magnet Strength Measurement Harmonic Number = 1 SL = 1.2741818 +- 0.0005344 Tm^2/m^n 14:06:14 Magnet Current, Imag = 399.9770 A Vtrans = 3.999770 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:06:16 Magnet Current, Imag = 399.9940 A Vtrans = 3.999940 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:06:17 Magnet Current, Imag = 399.9910 A Vtrans = 3.999910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:06:19 Magnet Current, Imag = 399.9800 A Vtrans = 3.999800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:06:19 Magnet Current Measurement: Imag = 399.9855 +- 0.0072 A 14:06:19 Magnet current ramping to 450.0000 A... 14:06:42 Magnet Current, Imag = 450.0140 A Vtrans = 4.500140 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:06:44 Magnet Current, Imag = 450.0180 A Vtrans = 4.500180 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:06:45 Magnet Current, Imag = 450.0200 A Vtrans = 4.500200 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:06:47 Magnet Current, Imag = 450.0280 A Vtrans = 4.500280 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:06:47 Magnet Current Measurement: Imag = 450.0200 +- 0.0051 A 14:06:47 Magnetic Field Measurement Measuring the magnet strength... 14:06:47 Integrated Voltage Measurement... 14:07:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014124299 Vs 14:07:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014526172 Vs 14:07:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014131208 Vs 14:07:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014531792 Vs 14:07:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014126048 Vs 14:07:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014527494 Vs 14:08:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014121295 Vs 14:08:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014516697 Vs 14:08:16 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014325626 +- 0.000004470 Vs 14:08:16 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.014325626 +- 0.000004470 Vs BL = 1.43256258 +- 0.00044699 Tm 14:08:19 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.43256 0.00045 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.43256 0.00045 1.43256 0.00000 14:08:19 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.43256 0.00045 SL = 1.4325626 +- 0.0004470 Tm^2/m^n 14:08:19 Magnet Strength Measurement Harmonic Number = 1 SL = 1.4325626 +- 0.0004470 Tm^2/m^n 14:08:21 Magnet Current, Imag = 450.0260 A Vtrans = 4.500260 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:08:23 Magnet Current, Imag = 450.0260 A Vtrans = 4.500260 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:08:24 Magnet Current, Imag = 450.0330 A Vtrans = 4.500330 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:08:26 Magnet Current, Imag = 450.0520 A Vtrans = 4.500520 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:08:26 Magnet Current Measurement: Imag = 450.0342 +- 0.0106 A 14:08:26 Magnet current ramping to 500.0000 A... 14:08:49 Magnet Current, Imag = 500.0750 A Vtrans = 5.000750 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:08:51 Magnet Current, Imag = 500.0760 A Vtrans = 5.000760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:08:52 Magnet Current, Imag = 500.0800 A Vtrans = 5.000800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:08:54 Magnet Current, Imag = 500.0780 A Vtrans = 5.000780 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:08:54 Magnet Current Measurement: Imag = 500.0772 +- 0.0019 A 14:08:54 Magnetic Field Measurement Measuring the magnet strength... 14:08:54 Integrated Voltage Measurement... 14:09:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015708441 Vs 14:09:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016101761 Vs 14:09:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015712929 Vs 14:09:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016112738 Vs 14:09:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015724558 Vs 14:10:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016113213 Vs 14:10:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015712073 Vs 14:10:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016108422 Vs 14:10:23 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015911767 +- 0.000004964 Vs 14:10:23 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.015911767 +- 0.000004964 Vs BL = 1.59117668 +- 0.00049639 Tm 14:10:26 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.59118 0.00050 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.59118 0.00050 1.59118 0.00000 14:10:26 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.59118 0.00050 SL = 1.5911767 +- 0.0004964 Tm^2/m^n 14:10:26 Magnet Strength Measurement Harmonic Number = 1 SL = 1.5911767 +- 0.0004964 Tm^2/m^n 14:10:28 Magnet Current, Imag = 500.0750 A Vtrans = 5.000750 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:10:30 Magnet Current, Imag = 500.0600 A Vtrans = 5.000600 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:10:31 Magnet Current, Imag = 500.0710 A Vtrans = 5.000710 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:10:33 Magnet Current, Imag = 500.0710 A Vtrans = 5.000710 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:10:33 Magnet Current Measurement: Imag = 500.0692 +- 0.0056 A 14:10:33 Magnet current ramping to 525.0000 A... 14:10:49 Magnet Current, Imag = 525.0540 A Vtrans = 5.250540 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:10:50 Magnet Current, Imag = 525.0700 A Vtrans = 5.250700 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:10:52 Magnet Current, Imag = 525.0780 A Vtrans = 5.250780 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:10:53 Magnet Current, Imag = 525.0770 A Vtrans = 5.250770 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:10:54 Magnet Current Measurement: Imag = 525.0697 +- 0.0096 A 14:10:54 Magnetic Field Measurement Measuring the magnet strength... 14:10:54 Integrated Voltage Measurement... 14:11:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016503044 Vs 14:11:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016897675 Vs 14:11:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016487549 Vs 14:11:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016896498 Vs 14:11:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016511944 Vs 14:12:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016905164 Vs 14:12:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016489501 Vs 14:12:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016904937 Vs 14:12:22 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016699539 +- 0.000005996 Vs 14:12:23 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.016699539 +- 0.000005996 Vs BL = 1.66995392 +- 0.00059959 Tm 14:12:26 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.66995 0.00060 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.66995 0.00060 1.66995 0.00000 14:12:26 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.66995 0.00060 SL = 1.6699539 +- 0.0005996 Tm^2/m^n 14:12:26 Magnet Strength Measurement Harmonic Number = 1 SL = 1.6699539 +- 0.0005996 Tm^2/m^n 14:12:27 Magnet Current, Imag = 525.1000 A Vtrans = 5.251000 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:12:29 Magnet Current, Imag = 525.0970 A Vtrans = 5.250970 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:12:31 Magnet Current, Imag = 525.1050 A Vtrans = 5.251050 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:12:32 Magnet Current, Imag = 525.1050 A Vtrans = 5.251050 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:12:32 Magnet Current Measurement: Imag = 525.1017 +- 0.0034 A 14:12:32 Magnet current ramping to 550.0000 A... 14:12:48 Magnet Current, Imag = 550.0400 A Vtrans = 5.500400 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:12:50 Magnet Current, Imag = 550.0600 A Vtrans = 5.500600 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:12:51 Magnet Current, Imag = 550.0560 A Vtrans = 5.500560 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:12:53 Magnet Current, Imag = 550.0620 A Vtrans = 5.500620 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:12:53 Magnet Current Measurement: Imag = 550.0545 +- 0.0086 A 14:12:53 Magnetic Field Measurement Measuring the magnet strength... 14:12:53 Integrated Voltage Measurement... 14:13:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017285959 Vs 14:13:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017679940 Vs 14:13:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017287613 Vs 14:13:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017679504 Vs 14:13:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017282197 Vs 14:14:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017669390 Vs 14:14:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017288545 Vs 14:14:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017676392 Vs 14:14:22 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017481192 +- 0.000003141 Vs 14:14:22 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.017481192 +- 0.000003141 Vs BL = 1.74811924 +- 0.00031410 Tm 14:14:25 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.74812 0.00031 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.74812 0.00031 1.74812 0.00000 14:14:25 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.74812 0.00031 SL = 1.7481192 +- 0.0003141 Tm^2/m^n 14:14:25 Magnet Strength Measurement Harmonic Number = 1 SL = 1.7481192 +- 0.0003141 Tm^2/m^n 14:14:27 Magnet Current, Imag = 550.0610 A Vtrans = 5.500610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:14:29 Magnet Current, Imag = 550.0670 A Vtrans = 5.500670 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:14:30 Magnet Current, Imag = 550.0640 A Vtrans = 5.500640 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:14:32 Magnet Current, Imag = 550.0670 A Vtrans = 5.500670 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:14:32 Magnet Current Measurement: Imag = 550.0648 +- 0.0025 A 14:14:32 Magnet current ramping to 575.0000 A... 14:14:48 Magnet Current, Imag = 575.0570 A Vtrans = 5.750570 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:14:49 Magnet Current, Imag = 575.0810 A Vtrans = 5.750810 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:14:51 Magnet Current, Imag = 575.1010 A Vtrans = 5.751010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:14:52 Magnet Current, Imag = 575.0960 A Vtrans = 5.750960 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:14:52 Magnet Current Measurement: Imag = 575.0838 +- 0.0171 A 14:14:53 Magnetic Field Measurement Measuring the magnet strength... 14:14:53 Integrated Voltage Measurement... 14:15:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018054390 Vs 14:15:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018461135 Vs 14:15:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018048637 Vs 14:15:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018458744 Vs 14:15:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018065733 Vs 14:16:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018441439 Vs 14:16:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018059229 Vs 14:16:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018452614 Vs 14:16:21 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018255240 +- 0.000001729 Vs 14:16:22 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.018255240 +- 0.000001729 Vs BL = 1.82552402 +- 0.00017293 Tm 14:16:25 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.82552 0.00017 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.82552 0.00017 1.82552 0.00000 14:16:25 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.82552 0.00017 SL = 1.8255240 +- 0.0001729 Tm^2/m^n 14:16:25 Magnet Strength Measurement Harmonic Number = 1 SL = 1.8255240 +- 0.0001729 Tm^2/m^n 14:16:26 Magnet Current, Imag = 575.0870 A Vtrans = 5.750870 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:16:28 Magnet Current, Imag = 575.0980 A Vtrans = 5.750980 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:16:30 Magnet Current, Imag = 575.0850 A Vtrans = 5.750850 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:16:31 Magnet Current, Imag = 575.0680 A Vtrans = 5.750680 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:16:31 Magnet Current Measurement: Imag = 575.0845 +- 0.0107 A 14:16:31 Magnet current ramping to 600.0000 A... 14:16:47 Magnet Current, Imag = 600.1060 A Vtrans = 6.001060 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:16:49 Magnet Current, Imag = 600.1020 A Vtrans = 6.001020 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:16:50 Magnet Current, Imag = 600.0900 A Vtrans = 6.000900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:16:52 Magnet Current, Imag = 600.1110 A Vtrans = 6.001110 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:16:52 Magnet Current Measurement: Imag = 600.1023 +- 0.0078 A 14:16:52 Magnetic Field Measurement Measuring the magnet strength... 14:16:52 Integrated Voltage Measurement... 14:17:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018812384 Vs 14:17:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019201174 Vs 14:17:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018808981 Vs 14:17:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019216841 Vs 14:17:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018826401 Vs 14:17:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019202675 Vs 14:18:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018816943 Vs 14:18:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019204723 Vs 14:18:21 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019011265 +- 0.000002904 Vs 14:18:21 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.019011265 +- 0.000002904 Vs BL = 1.90112650 +- 0.00029039 Tm 14:18:24 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.90113 0.00029 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.90113 0.00029 1.90113 0.00000 14:18:24 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.90113 0.00029 SL = 1.9011265 +- 0.0002904 Tm^2/m^n 14:18:24 Magnet Strength Measurement Harmonic Number = 1 SL = 1.9011265 +- 0.0002904 Tm^2/m^n 14:18:26 Magnet Current, Imag = 600.1110 A Vtrans = 6.001110 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:18:27 Magnet Current, Imag = 600.0990 A Vtrans = 6.000990 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:18:29 Magnet Current, Imag = 600.1000 A Vtrans = 6.001000 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:18:31 Magnet Current, Imag = 600.1150 A Vtrans = 6.001150 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:18:31 Magnet Current Measurement: Imag = 600.1063 +- 0.0069 A 14:18:31 Magnet current ramping to 625.0000 A... 14:18:47 Magnet Current, Imag = 625.1810 A Vtrans = 6.251810 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:18:48 Magnet Current, Imag = 625.1630 A Vtrans = 6.251630 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:18:50 Magnet Current, Imag = 625.1440 A Vtrans = 6.251440 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:18:51 Magnet Current, Imag = 625.1430 A Vtrans = 6.251430 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:18:51 Magnet Current Measurement: Imag = 625.1577 +- 0.0156 A 14:18:51 Magnetic Field Measurement Measuring the magnet strength... 14:18:52 Integrated Voltage Measurement... 14:19:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019566425 Vs 14:19:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019961285 Vs 14:19:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019547295 Vs 14:19:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019963499 Vs 14:19:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019570410 Vs 14:19:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019956096 Vs 14:20:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019573373 Vs 14:20:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019966001 Vs 14:20:20 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019763048 +- 0.000005082 Vs 14:20:20 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.019763048 +- 0.000005082 Vs BL = 1.97630481 +- 0.00050820 Tm 14:20:24 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.97630 0.00051 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.97630 0.00051 1.97630 0.00000 14:20:24 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.97630 0.00051 SL = 1.9763048 +- 0.0005082 Tm^2/m^n 14:20:24 Magnet Strength Measurement Harmonic Number = 1 SL = 1.9763048 +- 0.0005082 Tm^2/m^n 14:20:25 Magnet Current, Imag = 625.1470 A Vtrans = 6.251470 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:20:27 Magnet Current, Imag = 625.1500 A Vtrans = 6.251500 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:20:28 Magnet Current, Imag = 625.1390 A Vtrans = 6.251390 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:20:30 Magnet Current, Imag = 625.1530 A Vtrans = 6.251530 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:20:30 Magnet Current Measurement: Imag = 625.1472 +- 0.0052 A 14:20:30 Magnet current ramping to 650.0000 A... 14:20:46 Magnet Current, Imag = 650.1470 A Vtrans = 6.501470 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:20:48 Magnet Current, Imag = 650.1460 A Vtrans = 6.501460 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:20:49 Magnet Current, Imag = 650.1460 A Vtrans = 6.501460 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:20:51 Magnet Current, Imag = 650.1320 A Vtrans = 6.501320 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:20:51 Magnet Current Measurement: Imag = 650.1427 +- 0.0062 A 14:20:51 Magnetic Field Measurement Measuring the magnet strength... 14:20:51 Integrated Voltage Measurement... 14:21:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020279297 Vs 14:21:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020668405 Vs 14:21:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020273549 Vs 14:21:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020661527 Vs 14:21:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020276869 Vs 14:21:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020669577 Vs 14:22:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020267788 Vs 14:22:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020671477 Vs 14:22:20 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020471061 +- 0.000002594 Vs 14:22:20 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.020471061 +- 0.000002594 Vs BL = 2.04710610 +- 0.00025937 Tm 14:22:23 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.04711 0.00026 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.04711 0.00026 2.04711 0.00000 14:22:23 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.04711 0.00026 SL = 2.0471061 +- 0.0002594 Tm^2/m^n 14:22:23 Magnet Strength Measurement Harmonic Number = 1 SL = 2.0471061 +- 0.0002594 Tm^2/m^n 14:22:25 Magnet Current, Imag = 650.1550 A Vtrans = 6.501550 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:22:26 Magnet Current, Imag = 650.1530 A Vtrans = 6.501530 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:22:28 Magnet Current, Imag = 650.1610 A Vtrans = 6.501610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:22:29 Magnet Current, Imag = 650.1650 A Vtrans = 6.501650 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:22:29 Magnet Current Measurement: Imag = 650.1585 +- 0.0048 A 14:22:30 Magnet current ramping to 675.0000 A... 14:22:45 Magnet Current, Imag = 675.1800 A Vtrans = 6.751800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:22:47 Magnet Current, Imag = 675.1840 A Vtrans = 6.751840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:22:49 Magnet Current, Imag = 675.1810 A Vtrans = 6.751810 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:22:50 Magnet Current, Imag = 675.1750 A Vtrans = 6.751750 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:22:50 Magnet Current Measurement: Imag = 675.1800 +- 0.0032 A 14:22:50 Magnetic Field Measurement Measuring the magnet strength... 14:22:50 Integrated Voltage Measurement... 14:23:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020931179 Vs 14:23:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021334541 Vs 14:23:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020938719 Vs 14:23:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021334813 Vs 14:23:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020953826 Vs 14:23:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021325905 Vs 14:24:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020945461 Vs 14:24:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021335009 Vs 14:24:19 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021137431 +- 0.000002963 Vs 14:24:19 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.021137431 +- 0.000002963 Vs BL = 2.11374315 +- 0.00029633 Tm 14:24:22 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.11374 0.00030 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.11374 0.00030 2.11374 0.00000 14:24:22 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.11374 0.00030 SL = 2.1137431 +- 0.0002963 Tm^2/m^n 14:24:22 Magnet Strength Measurement Harmonic Number = 1 SL = 2.1137431 +- 0.0002963 Tm^2/m^n 14:24:24 Magnet Current, Imag = 675.1860 A Vtrans = 6.751860 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:24:26 Magnet Current, Imag = 675.1880 A Vtrans = 6.751880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:24:27 Magnet Current, Imag = 675.1880 A Vtrans = 6.751880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:24:29 Magnet Current, Imag = 675.1840 A Vtrans = 6.751840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:24:29 Magnet Current Measurement: Imag = 675.1865 +- 0.0017 A 14:24:29 Magnet current ramping to 700.0000 A... 14:24:45 Magnet Current, Imag = 700.1810 A Vtrans = 7.001810 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:24:46 Magnet Current, Imag = 700.1840 A Vtrans = 7.001840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:24:48 Magnet Current, Imag = 700.1930 A Vtrans = 7.001930 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:24:50 Magnet Current, Imag = 700.1790 A Vtrans = 7.001790 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:24:50 Magnet Current Measurement: Imag = 700.1843 +- 0.0054 A 14:24:50 Magnetic Field Measurement Measuring the magnet strength... 14:24:50 Integrated Voltage Measurement... 14:25:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021564445 Vs 14:25:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021949085 Vs 14:25:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021562783 Vs 14:25:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021952905 Vs 14:25:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021540091 Vs 14:25:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021955070 Vs 14:26:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021567205 Vs 14:26:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021957226 Vs 14:26:18 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021756101 +- 0.000005326 Vs 14:26:19 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.021756101 +- 0.000005326 Vs BL = 2.17561013 +- 0.00053261 Tm 14:26:22 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.17561 0.00053 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.17561 0.00053 2.17561 0.00000 14:26:22 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.17561 0.00053 SL = 2.1756101 +- 0.0005326 Tm^2/m^n 14:26:22 Magnet Strength Measurement Harmonic Number = 1 SL = 2.1756101 +- 0.0005326 Tm^2/m^n 14:26:24 Magnet Current, Imag = 700.2020 A Vtrans = 7.002020 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:26:25 Magnet Current, Imag = 700.1580 A Vtrans = 7.001580 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:26:27 Magnet Current, Imag = 700.1390 A Vtrans = 7.001390 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:26:28 Magnet Current, Imag = 700.1520 A Vtrans = 7.001520 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:26:28 Magnet Current Measurement: Imag = 700.1627 +- 0.0237 A 14:26:29 Magnet current ramping to 650.0000 A... 14:26:52 Magnet Current, Imag = 650.1390 A Vtrans = 6.501390 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:26:53 Magnet Current, Imag = 650.1290 A Vtrans = 6.501290 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:26:55 Magnet Current, Imag = 650.1250 A Vtrans = 6.501250 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:26:56 Magnet Current, Imag = 650.1420 A Vtrans = 6.501420 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:26:56 Magnet Current Measurement: Imag = 650.1337 +- 0.0070 A 14:26:57 Magnetic Field Measurement Measuring the magnet strength... 14:26:57 Integrated Voltage Measurement... 14:27:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020349438 Vs 14:27:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020745027 Vs 14:27:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020364457 Vs 14:27:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020735291 Vs 14:27:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020359980 Vs 14:28:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020745491 Vs 14:28:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020347645 Vs 14:28:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020749265 Vs 14:28:25 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020549574 +- 0.000002051 Vs 14:28:25 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.020549574 +- 0.000002051 Vs BL = 2.05495742 +- 0.00020507 Tm 14:28:28 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.05496 0.00021 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.05496 0.00021 2.05496 0.00000 14:28:29 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.05496 0.00021 SL = 2.0549574 +- 0.0002051 Tm^2/m^n 14:28:29 Magnet Strength Measurement Harmonic Number = 1 SL = 2.0549574 +- 0.0002051 Tm^2/m^n 14:28:30 Magnet Current, Imag = 650.1280 A Vtrans = 6.501280 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:28:32 Magnet Current, Imag = 650.1290 A Vtrans = 6.501290 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:28:34 Magnet Current, Imag = 650.1520 A Vtrans = 6.501520 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:28:35 Magnet Current, Imag = 650.1210 A Vtrans = 6.501210 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:28:35 Magnet Current Measurement: Imag = 650.1325 +- 0.0117 A 14:28:35 Magnet current ramping to 600.0000 A... 14:28:58 Magnet Current, Imag = 600.0720 A Vtrans = 6.000720 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:29:00 Magnet Current, Imag = 600.0980 A Vtrans = 6.000980 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:29:02 Magnet Current, Imag = 600.0940 A Vtrans = 6.000940 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:29:03 Magnet Current, Imag = 600.0970 A Vtrans = 6.000970 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:29:03 Magnet Current Measurement: Imag = 600.0902 +- 0.0106 A 14:29:03 Magnetic Field Measurement Measuring the magnet strength... 14:29:03 Integrated Voltage Measurement... 14:29:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018907785 Vs 14:29:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019314011 Vs 14:29:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018901381 Vs 14:29:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019300074 Vs 14:30:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018909486 Vs 14:30:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019297113 Vs 14:30:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018906167 Vs 14:30:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019305526 Vs 14:30:32 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019105193 +- 0.000003758 Vs 14:30:32 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.019105193 +- 0.000003758 Vs BL = 1.91051930 +- 0.00037583 Tm 14:30:35 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.91052 0.00038 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.91052 0.00038 1.91052 0.00000 14:30:35 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.91052 0.00038 SL = 1.9105193 +- 0.0003758 Tm^2/m^n 14:30:36 Magnet Strength Measurement Harmonic Number = 1 SL = 1.9105193 +- 0.0003758 Tm^2/m^n 14:30:37 Magnet Current, Imag = 600.0800 A Vtrans = 6.000800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:30:39 Magnet Current, Imag = 600.0880 A Vtrans = 6.000880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:30:40 Magnet Current, Imag = 600.1050 A Vtrans = 6.001050 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:30:42 Magnet Current, Imag = 600.0840 A Vtrans = 6.000840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:30:42 Magnet Current Measurement: Imag = 600.0892 +- 0.0095 A 14:30:42 Magnet current ramping to 550.0000 A... 14:31:05 Magnet Current, Imag = 550.0720 A Vtrans = 5.500720 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:31:07 Magnet Current, Imag = 550.0820 A Vtrans = 5.500820 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:31:09 Magnet Current, Imag = 550.0710 A Vtrans = 5.500710 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:31:10 Magnet Current, Imag = 550.0700 A Vtrans = 5.500700 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:31:10 Magnet Current Measurement: Imag = 550.0738 +- 0.0048 A 14:31:10 Magnetic Field Measurement Measuring the magnet strength... 14:31:10 Integrated Voltage Measurement... 14:31:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017347059 Vs 14:31:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017750190 Vs 14:31:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017352293 Vs 14:31:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017741098 Vs 14:32:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017356321 Vs 14:32:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017764348 Vs 14:32:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017347096 Vs 14:32:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017758359 Vs 14:32:39 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017552095 +- 0.000005232 Vs 14:32:39 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.017552095 +- 0.000005232 Vs BL = 1.75520953 +- 0.00052318 Tm 14:32:42 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.75521 0.00052 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.75521 0.00052 1.75521 0.00000 14:32:42 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.75521 0.00052 SL = 1.7552095 +- 0.0005232 Tm^2/m^n 14:32:42 Magnet Strength Measurement Harmonic Number = 1 SL = 1.7552095 +- 0.0005232 Tm^2/m^n 14:32:44 Magnet Current, Imag = 550.0480 A Vtrans = 5.500480 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:32:46 Magnet Current, Imag = 550.0390 A Vtrans = 5.500390 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:32:47 Magnet Current, Imag = 550.0360 A Vtrans = 5.500360 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:32:49 Magnet Current, Imag = 550.0440 A Vtrans = 5.500440 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:32:49 Magnet Current Measurement: Imag = 550.0417 +- 0.0046 A 14:32:49 Magnet current ramping to 500.0000 A... 14:33:12 Magnet Current, Imag = 500.0700 A Vtrans = 5.000700 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:33:14 Magnet Current, Imag = 500.0660 A Vtrans = 5.000660 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:33:16 Magnet Current, Imag = 500.0700 A Vtrans = 5.000700 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:33:17 Magnet Current, Imag = 500.0610 A Vtrans = 5.000610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:33:17 Magnet Current Measurement: Imag = 500.0667 +- 0.0037 A 14:33:18 Magnetic Field Measurement Measuring the magnet strength... 14:33:18 Integrated Voltage Measurement... 14:33:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015789270 Vs 14:33:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016177476 Vs 14:33:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015767685 Vs 14:34:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016177777 Vs 14:34:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015776599 Vs 14:34:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016172639 Vs 14:34:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015772411 Vs 14:34:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016163611 Vs 14:34:46 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015974683 +- 0.000005564 Vs 14:34:46 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.015974683 +- 0.000005564 Vs BL = 1.59746835 +- 0.00055643 Tm 14:34:49 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.59747 0.00056 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.59747 0.00056 1.59747 0.00000 14:34:49 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.59747 0.00056 SL = 1.5974683 +- 0.0005564 Tm^2/m^n 14:34:49 Magnet Strength Measurement Harmonic Number = 1 SL = 1.5974683 +- 0.0005564 Tm^2/m^n 14:34:51 Magnet Current, Imag = 500.0730 A Vtrans = 5.000730 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:34:53 Magnet Current, Imag = 500.0810 A Vtrans = 5.000810 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:34:54 Magnet Current, Imag = 500.0770 A Vtrans = 5.000770 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:34:56 Magnet Current, Imag = 500.0760 A Vtrans = 5.000760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:34:56 Magnet Current Measurement: Imag = 500.0768 +- 0.0029 A 14:34:56 Magnet current ramping to 450.0000 A... 14:35:19 Magnet Current, Imag = 450.0360 A Vtrans = 4.500360 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:35:21 Magnet Current, Imag = 450.0210 A Vtrans = 4.500210 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:35:22 Magnet Current, Imag = 450.0220 A Vtrans = 4.500220 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:35:24 Magnet Current, Imag = 450.0030 A Vtrans = 4.500030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:35:24 Magnet Current Measurement: Imag = 450.0205 +- 0.0117 A 14:35:24 Magnetic Field Measurement Measuring the magnet strength... 14:35:24 Integrated Voltage Measurement... 14:35:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014183985 Vs 14:35:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014579799 Vs 14:35:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014195874 Vs 14:36:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014587765 Vs 14:36:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014178399 Vs 14:36:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014587337 Vs 14:36:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014197262 Vs 14:36:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014584110 Vs 14:36:53 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014386816 +- 0.000004468 Vs 14:36:53 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.014386816 +- 0.000004468 Vs BL = 1.43868165 +- 0.00044676 Tm 14:36:56 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.43868 0.00045 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.43868 0.00045 1.43868 0.00000 14:36:56 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.43868 0.00045 SL = 1.4386816 +- 0.0004468 Tm^2/m^n 14:36:56 Magnet Strength Measurement Harmonic Number = 1 SL = 1.4386816 +- 0.0004468 Tm^2/m^n 14:36:58 Magnet Current, Imag = 450.0270 A Vtrans = 4.500270 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:37:00 Magnet Current, Imag = 450.0310 A Vtrans = 4.500310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:37:01 Magnet Current, Imag = 450.0200 A Vtrans = 4.500200 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:37:03 Magnet Current, Imag = 450.0230 A Vtrans = 4.500230 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:37:03 Magnet Current Measurement: Imag = 450.0252 +- 0.0041 A 14:37:03 Magnet current ramping to 400.0000 A... 14:37:26 Magnet Current, Imag = 400.0030 A Vtrans = 4.000030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:37:28 Magnet Current, Imag = 399.9970 A Vtrans = 3.999970 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:37:29 Magnet Current, Imag = 399.9910 A Vtrans = 3.999910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:37:31 Magnet Current, Imag = 399.9770 A Vtrans = 3.999770 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:37:31 Magnet Current Measurement: Imag = 399.9920 +- 0.0096 A 14:37:31 Magnetic Field Measurement Measuring the magnet strength... 14:37:31 Integrated Voltage Measurement... 14:37:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012601128 Vs 14:37:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012982289 Vs 14:38:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012604902 Vs 14:38:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012994415 Vs 14:38:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012595387 Vs 14:38:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012979325 Vs 14:38:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012585895 Vs 14:39:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012985581 Vs 14:39:00 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012791115 +- 0.000005394 Vs 14:39:00 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.012791115 +- 0.000005394 Vs BL = 1.27911154 +- 0.00053941 Tm 14:39:03 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.27911 0.00054 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.27911 0.00054 1.27911 0.00000 14:39:03 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.27911 0.00054 SL = 1.2791115 +- 0.0005394 Tm^2/m^n 14:39:03 Magnet Strength Measurement Harmonic Number = 1 SL = 1.2791115 +- 0.0005394 Tm^2/m^n 14:39:05 Magnet Current, Imag = 399.9890 A Vtrans = 3.999890 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:39:07 Magnet Current, Imag = 399.9760 A Vtrans = 3.999760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:39:08 Magnet Current, Imag = 399.9890 A Vtrans = 3.999890 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:39:10 Magnet Current, Imag = 399.9890 A Vtrans = 3.999890 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:39:10 Magnet Current Measurement: Imag = 399.9857 +- 0.0056 A 14:39:40 Magnet current ramping to 0.0000 A...