SLAC Magnetic Measurements Date: 07-18-2001 Time: 12:56:16 Project: spear3 Magnet Type: gdipole Magnet Name: 145d-014 Serial Number: Run Number: 11 Measurement Device: stretched wire Operator: jy Comment: 1 STDZ cycle, BL vs I, main Standardization: 1 cycles from 0.0 A to 770.0 A to 0.0 A Test Currents (A): 50.0 100.0 150.0 200.0 250.0 300.0 350.0 400.0 450.0 500.0 525.0 550.0 575.0 600.0 625.0 650.0 675.0 700.0 650.0 600.0 550.0 500.0 450.0 400.0 12:56:23 Initial Zero Current Measurement, Imag_zero = 0.0000 A 12:56:23 Magnet current ramping to 15.0000 A... 12:56:55 Magnet current ramping to 770.0000 A... 13:01:12 Magnet current ramping to 0.0000 A... 13:06:03 Magnet current ramping to 50.0000 A... 13:06:27 Magnet Current, Imag = 43.9030 A Vtrans = 0.439030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:06:28 Magnet Current, Imag = 54.3188 A Vtrans = 0.543188 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:06:30 Magnet Current, Imag = 50.0976 A Vtrans = 0.500976 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:06:31 Magnet Current, Imag = 48.6083 A Vtrans = 0.486083 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:06:31 Magnet Current Measurement: Imag = 49.2319 +- 3.7220 A 13:06:32 Magnetic Field Measurement Measuring the magnet strength... 13:06:32 Integrated Voltage Measurement... 13:06:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001524737 Vs 13:06:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001602471 Vs 13:07:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001600268 Vs 13:07:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001603481 Vs 13:07:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001603295 Vs 13:07:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001610060 Vs 13:07:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001599013 Vs 13:08:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001600723 Vs 13:08:00 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001593006 +- 0.000017155 Vs 13:08:01 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.001593006 +- 0.000017155 Vs BL = 0.15930060 +- 0.00171546 Tm 13:08:04 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.15930 0.00172 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.15930 0.00172 0.15930 0.00000 13:08:04 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.15930 0.00172 SL = 0.1593006 +- 0.0017155 Tm^2/m^n 13:08:04 Magnet Strength Measurement Harmonic Number = 1 SL = 0.1593006 +- 0.0017155 Tm^2/m^n 13:08:05 Magnet Current, Imag = 49.8873 A Vtrans = 0.498873 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:08:07 Magnet Current, Imag = 49.8938 A Vtrans = 0.498938 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:08:08 Magnet Current, Imag = 49.9000 A Vtrans = 0.499000 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:08:10 Magnet Current, Imag = 49.8951 A Vtrans = 0.498951 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:08:10 Magnet Current Measurement: Imag = 49.8941 +- 0.0045 A 13:08:10 Magnet current ramping to 100.0000 A... 13:08:33 Magnet Current, Imag = 99.9486 A Vtrans = 0.999486 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:08:35 Magnet Current, Imag = 99.9362 A Vtrans = 0.999362 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:08:36 Magnet Current, Imag = 99.9190 A Vtrans = 0.999190 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:08:38 Magnet Current, Imag = 99.9246 A Vtrans = 0.999246 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:08:38 Magnet Current Measurement: Imag = 99.9321 +- 0.0114 A 13:08:38 Magnetic Field Measurement Measuring the magnet strength... 13:08:38 Integrated Voltage Measurement... 13:08:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003173659 Vs 13:09:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003180477 Vs 13:09:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003180103 Vs 13:09:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003174732 Vs 13:09:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003181910 Vs 13:09:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003182569 Vs 13:09:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003179707 Vs 13:10:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003186587 Vs 13:10:06 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003179968 +- 0.000002747 Vs 13:10:06 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.003179968 +- 0.000002747 Vs BL = 0.31799681 +- 0.00027468 Tm 13:10:09 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.31800 0.00027 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.31800 0.00027 0.31800 0.00000 13:10:09 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.31800 0.00027 SL = 0.3179968 +- 0.0002747 Tm^2/m^n 13:10:10 Magnet Strength Measurement Harmonic Number = 1 SL = 0.3179968 +- 0.0002747 Tm^2/m^n 13:10:11 Magnet Current, Imag = 99.9349 A Vtrans = 0.999349 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:10:13 Magnet Current, Imag = 99.9371 A Vtrans = 0.999371 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:10:14 Magnet Current, Imag = 99.9290 A Vtrans = 0.999290 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:10:16 Magnet Current, Imag = 99.9136 A Vtrans = 0.999136 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:10:16 Magnet Current Measurement: Imag = 99.9287 +- 0.0092 A 13:10:16 Magnet current ramping to 150.0000 A... 13:10:39 Magnet Current, Imag = 149.9457 A Vtrans = 1.499457 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:10:40 Magnet Current, Imag = 149.9350 A Vtrans = 1.499350 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:10:42 Magnet Current, Imag = 149.9498 A Vtrans = 1.499498 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:10:43 Magnet Current, Imag = 149.9802 A Vtrans = 1.499802 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:10:43 Magnet Current Measurement: Imag = 149.9527 +- 0.0168 A 13:10:43 Magnetic Field Measurement Measuring the magnet strength... 13:10:44 Integrated Voltage Measurement... 13:10:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004771123 Vs 13:11:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004778728 Vs 13:11:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004770703 Vs 13:11:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004766226 Vs 13:11:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004764485 Vs 13:11:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004774177 Vs 13:12:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004774483 Vs 13:12:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004766835 Vs 13:12:12 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004770845 +- 0.000002482 Vs 13:12:12 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.004770845 +- 0.000002482 Vs BL = 0.47708452 +- 0.00024820 Tm 13:12:15 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.47708 0.00025 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.47708 0.00025 0.47708 0.00000 13:12:15 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.47708 0.00025 SL = 0.4770845 +- 0.0002482 Tm^2/m^n 13:12:15 Magnet Strength Measurement Harmonic Number = 1 SL = 0.4770845 +- 0.0002482 Tm^2/m^n 13:12:17 Magnet Current, Imag = 149.9232 A Vtrans = 1.499232 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:12:18 Magnet Current, Imag = 149.9354 A Vtrans = 1.499354 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:12:20 Magnet Current, Imag = 149.9610 A Vtrans = 1.499610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:12:21 Magnet Current, Imag = 149.9691 A Vtrans = 1.499691 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:12:22 Magnet Current Measurement: Imag = 149.9472 +- 0.0186 A 13:12:22 Magnet current ramping to 200.0000 A... 13:12:45 Magnet Current, Imag = 199.9445 A Vtrans = 1.999445 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:12:46 Magnet Current, Imag = 199.9319 A Vtrans = 1.999319 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:12:48 Magnet Current, Imag = 199.9310 A Vtrans = 1.999310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:12:49 Magnet Current, Imag = 199.9559 A Vtrans = 1.999559 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:12:49 Magnet Current Measurement: Imag = 199.9408 +- 0.0102 A 13:12:49 Magnetic Field Measurement Measuring the magnet strength... 13:12:49 Integrated Voltage Measurement... 13:13:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006361804 Vs 13:13:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006377121 Vs 13:13:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006354544 Vs 13:13:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006367424 Vs 13:13:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006357883 Vs 13:13:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006369245 Vs 13:14:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006353688 Vs 13:14:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006368455 Vs 13:14:18 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006363771 +- 0.000003446 Vs 13:14:18 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.006363771 +- 0.000003446 Vs BL = 0.63637706 +- 0.00034457 Tm 13:14:21 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.63638 0.00034 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.63638 0.00034 0.63638 0.00000 13:14:22 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.63638 0.00034 SL = 0.6363771 +- 0.0003446 Tm^2/m^n 13:14:22 Magnet Strength Measurement Harmonic Number = 1 SL = 0.6363771 +- 0.0003446 Tm^2/m^n 13:14:23 Magnet Current, Imag = 199.9383 A Vtrans = 1.999383 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:14:25 Magnet Current, Imag = 199.9565 A Vtrans = 1.999565 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:14:26 Magnet Current, Imag = 199.9607 A Vtrans = 1.999607 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:14:28 Magnet Current, Imag = 199.9559 A Vtrans = 1.999559 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:14:28 Magnet Current Measurement: Imag = 199.9528 +- 0.0086 A 13:14:28 Magnet current ramping to 250.0000 A... 13:14:51 Magnet Current, Imag = 249.9883 A Vtrans = 2.499883 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:14:52 Magnet Current, Imag = 249.9647 A Vtrans = 2.499647 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:14:54 Magnet Current, Imag = 249.9547 A Vtrans = 2.499547 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:14:55 Magnet Current, Imag = 249.9767 A Vtrans = 2.499767 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:14:55 Magnet Current Measurement: Imag = 249.9711 +- 0.0126 A 13:14:56 Magnetic Field Measurement Measuring the magnet strength... 13:14:56 Integrated Voltage Measurement... 13:15:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007946735 Vs 13:15:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007961485 Vs 13:15:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007938063 Vs 13:15:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007959659 Vs 13:15:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007951455 Vs 13:16:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007957942 Vs 13:16:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007947135 Vs 13:16:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007962380 Vs 13:16:24 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007953107 +- 0.000002465 Vs 13:16:24 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.007953107 +- 0.000002465 Vs BL = 0.79531068 +- 0.00024645 Tm 13:16:28 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.79531 0.00025 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.79531 0.00025 0.79531 0.00000 13:16:28 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.79531 0.00025 SL = 0.7953107 +- 0.0002465 Tm^2/m^n 13:16:28 Magnet Strength Measurement Harmonic Number = 1 SL = 0.7953107 +- 0.0002465 Tm^2/m^n 13:16:29 Magnet Current, Imag = 249.9963 A Vtrans = 2.499963 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:16:31 Magnet Current, Imag = 249.9727 A Vtrans = 2.499727 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:16:32 Magnet Current, Imag = 249.9583 A Vtrans = 2.499583 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:16:34 Magnet Current, Imag = 249.9638 A Vtrans = 2.499638 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:16:34 Magnet Current Measurement: Imag = 249.9728 +- 0.0145 A 13:16:34 Magnet current ramping to 300.0000 A... 13:16:57 Magnet Current, Imag = 300.0126 A Vtrans = 3.000126 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:16:59 Magnet Current, Imag = 300.0138 A Vtrans = 3.000138 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:17:00 Magnet Current, Imag = 299.9986 A Vtrans = 2.999986 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:17:02 Magnet Current, Imag = 299.9967 A Vtrans = 2.999967 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:17:02 Magnet Current Measurement: Imag = 300.0054 +- 0.0078 A 13:17:02 Magnetic Field Measurement Measuring the magnet strength... 13:17:02 Integrated Voltage Measurement... 13:17:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009546457 Vs 13:17:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009561437 Vs 13:17:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009557430 Vs 13:17:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009553537 Vs 13:17:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009551458 Vs 13:18:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009540621 Vs 13:18:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009547825 Vs 13:18:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009546705 Vs 13:18:30 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009550684 +- 0.000004091 Vs 13:18:30 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.009550684 +- 0.000004091 Vs BL = 0.95506838 +- 0.00040909 Tm 13:18:34 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.95507 0.00041 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.95507 0.00041 0.95507 0.00000 13:18:34 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.95507 0.00041 SL = 0.9550684 +- 0.0004091 Tm^2/m^n 13:18:34 Magnet Strength Measurement Harmonic Number = 1 SL = 0.9550684 +- 0.0004091 Tm^2/m^n 13:18:35 Magnet Current, Imag = 300.0089 A Vtrans = 3.000089 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:18:37 Magnet Current, Imag = 299.9977 A Vtrans = 2.999977 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:18:38 Magnet Current, Imag = 300.0058 A Vtrans = 3.000058 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:18:40 Magnet Current, Imag = 300.0044 A Vtrans = 3.000044 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:18:40 Magnet Current Measurement: Imag = 300.0042 +- 0.0041 A 13:18:40 Magnet current ramping to 350.0000 A... 13:19:03 Magnet Current, Imag = 350.0330 A Vtrans = 3.500330 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:19:05 Magnet Current, Imag = 350.0410 A Vtrans = 3.500410 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:19:07 Magnet Current, Imag = 350.0620 A Vtrans = 3.500620 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:19:09 Magnet Current, Imag = 350.0490 A Vtrans = 3.500490 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:19:09 Magnet Current Measurement: Imag = 350.0462 +- 0.0107 A 13:19:09 Magnetic Field Measurement Measuring the magnet strength... 13:19:09 Integrated Voltage Measurement... 13:19:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011131779 Vs 13:19:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011138463 Vs 13:19:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011147209 Vs 13:19:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011150335 Vs 13:20:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011140945 Vs 13:20:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011152233 Vs 13:20:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011133996 Vs 13:20:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011149927 Vs 13:20:38 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011143111 +- 0.000005228 Vs 13:20:38 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.011143111 +- 0.000005228 Vs BL = 1.11431108 +- 0.00052276 Tm 13:20:41 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.11431 0.00052 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.11431 0.00052 1.11431 0.00000 13:20:41 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.11431 0.00052 SL = 1.1143111 +- 0.0005228 Tm^2/m^n 13:20:41 Magnet Strength Measurement Harmonic Number = 1 SL = 1.1143111 +- 0.0005228 Tm^2/m^n 13:20:43 Magnet Current, Imag = 350.0520 A Vtrans = 3.500520 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:20:45 Magnet Current, Imag = 350.0510 A Vtrans = 3.500510 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:20:47 Magnet Current, Imag = 350.0510 A Vtrans = 3.500510 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:20:49 Magnet Current, Imag = 350.0430 A Vtrans = 3.500430 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:20:49 Magnet Current Measurement: Imag = 350.0492 +- 0.0036 A 13:20:49 Magnet current ramping to 400.0000 A... 13:21:13 Magnet Current, Imag = 400.0380 A Vtrans = 4.000380 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:21:15 Magnet Current, Imag = 400.0320 A Vtrans = 4.000320 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:21:16 Magnet Current, Imag = 400.0370 A Vtrans = 4.000370 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:21:18 Magnet Current, Imag = 400.0400 A Vtrans = 4.000400 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:21:18 Magnet Current Measurement: Imag = 400.0367 +- 0.0029 A 13:21:18 Magnetic Field Measurement Measuring the magnet strength... 13:21:18 Integrated Voltage Measurement... 13:21:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012719636 Vs 13:21:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012728699 Vs 13:21:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012726424 Vs 13:22:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012739639 Vs 13:22:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012724207 Vs 13:22:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012746277 Vs 13:22:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012737035 Vs 13:22:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012747047 Vs 13:22:47 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012733621 +- 0.000006388 Vs 13:22:47 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.012733621 +- 0.000006388 Vs BL = 1.27336205 +- 0.00063882 Tm 13:22:50 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.27336 0.00064 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.27336 0.00064 1.27336 0.00000 13:22:50 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.27336 0.00064 SL = 1.2733621 +- 0.0006388 Tm^2/m^n 13:22:50 Magnet Strength Measurement Harmonic Number = 1 SL = 1.2733621 +- 0.0006388 Tm^2/m^n 13:22:52 Magnet Current, Imag = 400.0530 A Vtrans = 4.000530 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:22:54 Magnet Current, Imag = 400.0550 A Vtrans = 4.000550 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:22:55 Magnet Current, Imag = 400.0440 A Vtrans = 4.000440 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:22:57 Magnet Current, Imag = 400.0430 A Vtrans = 4.000430 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:22:57 Magnet Current Measurement: Imag = 400.0487 +- 0.0053 A 13:22:57 Magnet current ramping to 450.0000 A... 13:23:21 Magnet Current, Imag = 450.0800 A Vtrans = 4.500800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:23:22 Magnet Current, Imag = 450.0610 A Vtrans = 4.500610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:23:24 Magnet Current, Imag = 450.0610 A Vtrans = 4.500610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:23:25 Magnet Current, Imag = 450.0650 A Vtrans = 4.500650 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:23:25 Magnet Current Measurement: Imag = 450.0667 +- 0.0078 A 13:23:26 Magnetic Field Measurement Measuring the magnet strength... 13:23:26 Integrated Voltage Measurement... 13:23:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014313340 Vs 13:23:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014325889 Vs 13:24:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014316821 Vs 13:24:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014335706 Vs 13:24:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014319024 Vs 13:24:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014331697 Vs 13:24:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014316889 Vs 13:24:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014314789 Vs 13:24:54 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014321769 +- 0.000004269 Vs 13:24:55 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.014321769 +- 0.000004269 Vs BL = 1.43217694 +- 0.00042694 Tm 13:24:58 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.43218 0.00043 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.43218 0.00043 1.43218 0.00000 13:24:58 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.43218 0.00043 SL = 1.4321769 +- 0.0004269 Tm^2/m^n 13:24:58 Magnet Strength Measurement Harmonic Number = 1 SL = 1.4321769 +- 0.0004269 Tm^2/m^n 13:24:59 Magnet Current, Imag = 450.0710 A Vtrans = 4.500710 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:25:01 Magnet Current, Imag = 450.0850 A Vtrans = 4.500850 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:25:03 Magnet Current, Imag = 450.0920 A Vtrans = 4.500920 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:25:04 Magnet Current, Imag = 450.0920 A Vtrans = 4.500920 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:25:04 Magnet Current Measurement: Imag = 450.0850 +- 0.0086 A 13:25:04 Magnet current ramping to 500.0000 A... 13:25:28 Magnet Current, Imag = 500.1450 A Vtrans = 5.001450 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:25:30 Magnet Current, Imag = 500.1390 A Vtrans = 5.001390 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:25:31 Magnet Current, Imag = 500.1390 A Vtrans = 5.001390 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:25:33 Magnet Current, Imag = 500.1240 A Vtrans = 5.001240 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:25:33 Magnet Current Measurement: Imag = 500.1367 +- 0.0078 A 13:25:33 Magnetic Field Measurement Measuring the magnet strength... 13:25:33 Integrated Voltage Measurement... 13:25:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015907857 Vs 13:25:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015922450 Vs 13:26:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015903347 Vs 13:26:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015902045 Vs 13:26:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015900807 Vs 13:26:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015911567 Vs 13:26:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015898072 Vs 13:27:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015914677 Vs 13:27:03 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015907603 +- 0.000004599 Vs 13:27:03 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.015907603 +- 0.000004599 Vs BL = 1.59076027 +- 0.00045989 Tm 13:27:07 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.59076 0.00046 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.59076 0.00046 1.59076 0.00000 13:27:07 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.59076 0.00046 SL = 1.5907603 +- 0.0004599 Tm^2/m^n 13:27:07 Magnet Strength Measurement Harmonic Number = 1 SL = 1.5907603 +- 0.0004599 Tm^2/m^n 13:27:08 Magnet Current, Imag = 500.1320 A Vtrans = 5.001320 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:27:10 Magnet Current, Imag = 500.1360 A Vtrans = 5.001360 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:27:11 Magnet Current, Imag = 500.1280 A Vtrans = 5.001280 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:27:13 Magnet Current, Imag = 500.1220 A Vtrans = 5.001220 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:27:13 Magnet Current Measurement: Imag = 500.1295 +- 0.0052 A 13:27:13 Magnet current ramping to 525.0000 A... 13:27:29 Magnet Current, Imag = 525.1210 A Vtrans = 5.251210 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:27:31 Magnet Current, Imag = 525.1270 A Vtrans = 5.251270 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:27:32 Magnet Current, Imag = 525.1380 A Vtrans = 5.251380 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:27:34 Magnet Current, Imag = 525.1450 A Vtrans = 5.251450 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:27:34 Magnet Current Measurement: Imag = 525.1327 +- 0.0093 A 13:27:34 Magnetic Field Measurement Measuring the magnet strength... 13:27:34 Integrated Voltage Measurement... 13:27:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016703961 Vs 13:27:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016705779 Vs 13:28:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016697021 Vs 13:28:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016700479 Vs 13:28:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016701683 Vs 13:28:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016697403 Vs 13:28:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016696769 Vs 13:29:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016695642 Vs 13:29:03 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016699842 +- 0.000003154 Vs 13:29:03 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.016699842 +- 0.000003154 Vs BL = 1.66998422 +- 0.00031539 Tm 13:29:06 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.66998 0.00032 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.66998 0.00032 1.66998 0.00000 13:29:06 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.66998 0.00032 SL = 1.6699842 +- 0.0003154 Tm^2/m^n 13:29:06 Magnet Strength Measurement Harmonic Number = 1 SL = 1.6699842 +- 0.0003154 Tm^2/m^n 13:29:08 Magnet Current, Imag = 525.1260 A Vtrans = 5.251260 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:29:09 Magnet Current, Imag = 525.1220 A Vtrans = 5.251220 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:29:11 Magnet Current, Imag = 525.1230 A Vtrans = 5.251230 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:29:13 Magnet Current, Imag = 525.1440 A Vtrans = 5.251440 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:29:13 Magnet Current Measurement: Imag = 525.1288 +- 0.0089 A 13:29:13 Magnet current ramping to 550.0000 A... 13:29:29 Magnet Current, Imag = 550.0820 A Vtrans = 5.500820 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:29:30 Magnet Current, Imag = 550.0850 A Vtrans = 5.500850 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:29:32 Magnet Current, Imag = 550.0840 A Vtrans = 5.500840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:29:33 Magnet Current, Imag = 550.1010 A Vtrans = 5.501010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:29:33 Magnet Current Measurement: Imag = 550.0880 +- 0.0076 A 13:29:34 Magnetic Field Measurement Measuring the magnet strength... 13:29:34 Integrated Voltage Measurement... 13:29:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017471369 Vs 13:29:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017485373 Vs 13:30:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017476899 Vs 13:30:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017484433 Vs 13:30:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017477700 Vs 13:30:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017489891 Vs 13:30:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017474884 Vs 13:31:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017465733 Vs 13:31:03 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017478285 +- 0.000004992 Vs 13:31:03 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.017478285 +- 0.000004992 Vs BL = 1.74782854 +- 0.00049916 Tm 13:31:06 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.74783 0.00050 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.74783 0.00050 1.74783 0.00000 13:31:06 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.74783 0.00050 SL = 1.7478285 +- 0.0004992 Tm^2/m^n 13:31:06 Magnet Strength Measurement Harmonic Number = 1 SL = 1.7478285 +- 0.0004992 Tm^2/m^n 13:31:08 Magnet Current, Imag = 550.1160 A Vtrans = 5.501160 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:31:09 Magnet Current, Imag = 550.1090 A Vtrans = 5.501090 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:31:11 Magnet Current, Imag = 550.1100 A Vtrans = 5.501100 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:31:12 Magnet Current, Imag = 550.0910 A Vtrans = 5.500910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:31:12 Magnet Current Measurement: Imag = 550.1065 +- 0.0093 A 13:31:13 Magnet current ramping to 575.0000 A... 13:31:28 Magnet Current, Imag = 575.0920 A Vtrans = 5.750920 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:31:30 Magnet Current, Imag = 575.1180 A Vtrans = 5.751180 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:31:31 Magnet Current, Imag = 575.1240 A Vtrans = 5.751240 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:31:33 Magnet Current, Imag = 575.1350 A Vtrans = 5.751350 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:31:33 Magnet Current Measurement: Imag = 575.1173 +- 0.0158 A 13:31:33 Magnetic Field Measurement Measuring the magnet strength... 13:31:33 Integrated Voltage Measurement... 13:31:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018251027 Vs 13:31:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018252713 Vs 13:32:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018257128 Vs 13:32:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018259593 Vs 13:32:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018244917 Vs 13:32:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018253365 Vs 13:32:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018241027 Vs 13:33:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018254305 Vs 13:33:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018251760 +- 0.000004099 Vs 13:33:03 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.018251760 +- 0.000004099 Vs BL = 1.82517596 +- 0.00040987 Tm 13:33:06 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.82518 0.00041 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.82518 0.00041 1.82518 0.00000 13:33:06 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.82518 0.00041 SL = 1.8251760 +- 0.0004099 Tm^2/m^n 13:33:06 Magnet Strength Measurement Harmonic Number = 1 SL = 1.8251760 +- 0.0004099 Tm^2/m^n 13:33:07 Magnet Current, Imag = 575.1250 A Vtrans = 5.751250 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:33:09 Magnet Current, Imag = 575.1290 A Vtrans = 5.751290 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:33:11 Magnet Current, Imag = 575.1360 A Vtrans = 5.751360 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:33:12 Magnet Current, Imag = 575.1270 A Vtrans = 5.751270 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:33:12 Magnet Current Measurement: Imag = 575.1292 +- 0.0041 A 13:33:12 Magnet current ramping to 600.0000 A... 13:33:28 Magnet Current, Imag = 600.1330 A Vtrans = 6.001330 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:33:30 Magnet Current, Imag = 600.1600 A Vtrans = 6.001600 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:33:31 Magnet Current, Imag = 600.1600 A Vtrans = 6.001600 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:33:33 Magnet Current, Imag = 600.1430 A Vtrans = 6.001430 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:33:33 Magnet Current Measurement: Imag = 600.1490 +- 0.0116 A 13:33:33 Magnetic Field Measurement Measuring the magnet strength... 13:33:33 Integrated Voltage Measurement... 13:33:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019012084 Vs 13:33:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019013490 Vs 13:34:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019022724 Vs 13:34:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019020765 Vs 13:34:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019005731 Vs 13:34:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019015445 Vs 13:34:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019002598 Vs 13:35:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019015932 Vs 13:35:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019013596 +- 0.000004870 Vs 13:35:02 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.019013596 +- 0.000004870 Vs BL = 1.90135960 +- 0.00048697 Tm 13:35:05 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.90136 0.00049 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.90136 0.00049 1.90136 0.00000 13:35:06 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.90136 0.00049 SL = 1.9013596 +- 0.0004870 Tm^2/m^n 13:35:06 Magnet Strength Measurement Harmonic Number = 1 SL = 1.9013596 +- 0.0004870 Tm^2/m^n 13:35:07 Magnet Current, Imag = 600.1410 A Vtrans = 6.001410 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:35:09 Magnet Current, Imag = 600.1520 A Vtrans = 6.001520 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:35:10 Magnet Current, Imag = 600.1560 A Vtrans = 6.001560 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:35:12 Magnet Current, Imag = 600.1610 A Vtrans = 6.001610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:35:12 Magnet Current Measurement: Imag = 600.1525 +- 0.0074 A 13:35:12 Magnet current ramping to 625.0000 A... 13:35:28 Magnet Current, Imag = 625.1990 A Vtrans = 6.251990 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:35:30 Magnet Current, Imag = 625.1860 A Vtrans = 6.251860 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:35:31 Magnet Current, Imag = 625.1850 A Vtrans = 6.251850 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:35:33 Magnet Current, Imag = 625.1810 A Vtrans = 6.251810 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:35:33 Magnet Current Measurement: Imag = 625.1877 +- 0.0068 A 13:35:33 Magnetic Field Measurement Measuring the magnet strength... 13:35:33 Integrated Voltage Measurement... 13:35:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019749935 Vs 13:35:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019766367 Vs 13:36:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019743360 Vs 13:36:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019761209 Vs 13:36:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019745783 Vs 13:36:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019753984 Vs 13:36:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019751258 Vs 13:37:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019752545 Vs 13:37:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019753055 +- 0.000003080 Vs 13:37:02 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.019753055 +- 0.000003080 Vs BL = 1.97530551 +- 0.00030802 Tm 13:37:05 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.97531 0.00031 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.97531 0.00031 1.97531 0.00000 13:37:05 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.97531 0.00031 SL = 1.9753055 +- 0.0003080 Tm^2/m^n 13:37:05 Magnet Strength Measurement Harmonic Number = 1 SL = 1.9753055 +- 0.0003080 Tm^2/m^n 13:37:07 Magnet Current, Imag = 625.2040 A Vtrans = 6.252040 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:37:08 Magnet Current, Imag = 625.1990 A Vtrans = 6.251990 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:37:10 Magnet Current, Imag = 625.1810 A Vtrans = 6.251810 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:37:11 Magnet Current, Imag = 625.1670 A Vtrans = 6.251670 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:37:11 Magnet Current Measurement: Imag = 625.1877 +- 0.0147 A 13:37:12 Magnet current ramping to 650.0000 A... 13:37:27 Magnet Current, Imag = 650.1840 A Vtrans = 6.501840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:37:29 Magnet Current, Imag = 650.2080 A Vtrans = 6.502080 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:37:31 Magnet Current, Imag = 650.2010 A Vtrans = 6.502010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:37:33 Magnet Current, Imag = 650.1890 A Vtrans = 6.501890 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:37:33 Magnet Current Measurement: Imag = 650.1955 +- 0.0095 A 13:37:33 Magnetic Field Measurement Measuring the magnet strength... 13:37:33 Integrated Voltage Measurement... 13:37:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020453580 Vs 13:37:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020462731 Vs 13:38:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020460280 Vs 13:38:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020452598 Vs 13:38:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020453503 Vs 13:38:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020457223 Vs 13:38:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020453778 Vs 13:39:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020464081 Vs 13:39:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020457222 +- 0.000001401 Vs 13:39:02 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.020457222 +- 0.000001401 Vs BL = 2.04572217 +- 0.00014014 Tm 13:39:05 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.04572 0.00014 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.04572 0.00014 2.04572 0.00000 13:39:05 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.04572 0.00014 SL = 2.0457222 +- 0.0001401 Tm^2/m^n 13:39:05 Magnet Strength Measurement Harmonic Number = 1 SL = 2.0457222 +- 0.0001401 Tm^2/m^n 13:39:07 Magnet Current, Imag = 650.2020 A Vtrans = 6.502020 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:39:08 Magnet Current, Imag = 650.1920 A Vtrans = 6.501920 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:39:10 Magnet Current, Imag = 650.1890 A Vtrans = 6.501890 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:39:12 Magnet Current, Imag = 650.1860 A Vtrans = 6.501860 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:39:12 Magnet Current Measurement: Imag = 650.1923 +- 0.0060 A 13:39:12 Magnet current ramping to 675.0000 A... 13:39:28 Magnet Current, Imag = 675.1870 A Vtrans = 6.751870 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:39:29 Magnet Current, Imag = 675.2070 A Vtrans = 6.752070 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:39:31 Magnet Current, Imag = 675.2110 A Vtrans = 6.752110 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:39:32 Magnet Current, Imag = 675.2010 A Vtrans = 6.752010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:39:32 Magnet Current Measurement: Imag = 675.2015 +- 0.0091 A 13:39:33 Magnetic Field Measurement Measuring the magnet strength... 13:39:33 Integrated Voltage Measurement... 13:39:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021120519 Vs 13:39:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021126889 Vs 13:40:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021114376 Vs 13:40:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021126723 Vs 13:40:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021107383 Vs 13:40:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021131301 Vs 13:40:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021117763 Vs 13:41:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021126301 Vs 13:41:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021121407 +- 0.000001633 Vs 13:41:02 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.021121407 +- 0.000001633 Vs BL = 2.11214069 +- 0.00016329 Tm 13:41:05 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.11214 0.00016 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.11214 0.00016 2.11214 0.00000 13:41:05 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.11214 0.00016 SL = 2.1121407 +- 0.0001633 Tm^2/m^n 13:41:05 Magnet Strength Measurement Harmonic Number = 1 SL = 2.1121407 +- 0.0001633 Tm^2/m^n 13:41:07 Magnet Current, Imag = 675.1940 A Vtrans = 6.751940 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:41:09 Magnet Current, Imag = 675.1870 A Vtrans = 6.751870 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:41:10 Magnet Current, Imag = 675.2030 A Vtrans = 6.752030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:41:12 Magnet Current, Imag = 675.2090 A Vtrans = 6.752090 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:41:12 Magnet Current Measurement: Imag = 675.1982 +- 0.0084 A 13:41:12 Magnet current ramping to 700.0000 A... 13:41:28 Magnet Current, Imag = 700.2050 A Vtrans = 7.002050 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:41:29 Magnet Current, Imag = 700.1890 A Vtrans = 7.001890 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:41:31 Magnet Current, Imag = 700.2220 A Vtrans = 7.002220 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:41:32 Magnet Current, Imag = 700.1980 A Vtrans = 7.001980 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:41:32 Magnet Current Measurement: Imag = 700.2035 +- 0.0121 A 13:41:33 Magnetic Field Measurement Measuring the magnet strength... 13:41:33 Integrated Voltage Measurement... 13:41:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021743471 Vs 13:41:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021749017 Vs 13:42:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021736475 Vs 13:42:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021738683 Vs 13:42:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021730640 Vs 13:42:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021746754 Vs 13:42:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021734593 Vs 13:43:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021737767 Vs 13:43:01 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021739675 +- 0.000003896 Vs 13:43:01 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.021739675 +- 0.000003896 Vs BL = 2.17396748 +- 0.00038960 Tm 13:43:05 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.17397 0.00039 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.17397 0.00039 2.17397 0.00000 13:43:05 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.17397 0.00039 SL = 2.1739675 +- 0.0003896 Tm^2/m^n 13:43:05 Magnet Strength Measurement Harmonic Number = 1 SL = 2.1739675 +- 0.0003896 Tm^2/m^n 13:43:06 Magnet Current, Imag = 700.2130 A Vtrans = 7.002130 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:43:08 Magnet Current, Imag = 700.2180 A Vtrans = 7.002180 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:43:10 Magnet Current, Imag = 700.1930 A Vtrans = 7.001930 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:43:11 Magnet Current, Imag = 700.1750 A Vtrans = 7.001750 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:43:11 Magnet Current Measurement: Imag = 700.1997 +- 0.0171 A 13:43:11 Magnet current ramping to 650.0000 A... 13:43:35 Magnet Current, Imag = 650.2020 A Vtrans = 6.502020 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:43:36 Magnet Current, Imag = 650.1800 A Vtrans = 6.501800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:43:38 Magnet Current, Imag = 650.1820 A Vtrans = 6.501820 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:43:40 Magnet Current, Imag = 650.1870 A Vtrans = 6.501870 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:43:40 Magnet Current Measurement: Imag = 650.1877 +- 0.0086 A 13:43:40 Magnetic Field Measurement Measuring the magnet strength... 13:43:40 Integrated Voltage Measurement... 13:43:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020531048 Vs 13:44:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020537277 Vs 13:44:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020529074 Vs 13:44:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020534315 Vs 13:44:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020531491 Vs 13:44:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020537726 Vs 13:44:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020535409 Vs 13:45:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020545647 Vs 13:45:08 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020535248 +- 0.000003244 Vs 13:45:09 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.020535248 +- 0.000003244 Vs BL = 2.05352484 +- 0.00032439 Tm 13:45:12 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.05352 0.00032 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.05352 0.00032 2.05352 0.00000 13:45:12 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.05352 0.00032 SL = 2.0535248 +- 0.0003244 Tm^2/m^n 13:45:12 Magnet Strength Measurement Harmonic Number = 1 SL = 2.0535248 +- 0.0003244 Tm^2/m^n 13:45:13 Magnet Current, Imag = 650.1890 A Vtrans = 6.501890 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:45:15 Magnet Current, Imag = 650.1910 A Vtrans = 6.501910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:45:17 Magnet Current, Imag = 650.1830 A Vtrans = 6.501830 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:45:18 Magnet Current, Imag = 650.1860 A Vtrans = 6.501860 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:45:18 Magnet Current Measurement: Imag = 650.1872 +- 0.0030 A 13:45:18 Magnet current ramping to 600.0000 A... 13:45:42 Magnet Current, Imag = 600.1380 A Vtrans = 6.001380 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:45:44 Magnet Current, Imag = 600.1360 A Vtrans = 6.001360 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:45:45 Magnet Current, Imag = 600.1460 A Vtrans = 6.001460 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:45:47 Magnet Current, Imag = 600.1610 A Vtrans = 6.001610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:45:47 Magnet Current Measurement: Imag = 600.1452 +- 0.0098 A 13:45:47 Magnetic Field Measurement Measuring the magnet strength... 13:45:47 Integrated Voltage Measurement... 13:46:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019086882 Vs 13:46:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019106405 Vs 13:46:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019094789 Vs 13:46:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019096928 Vs 13:46:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019089253 Vs 13:46:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019103173 Vs 13:47:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019087803 Vs 13:47:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019096273 Vs 13:47:16 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019095188 +- 0.000001840 Vs 13:47:16 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.019095188 +- 0.000001840 Vs BL = 1.90951882 +- 0.00018399 Tm 13:47:19 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.90952 0.00018 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.90952 0.00018 1.90952 0.00000 13:47:19 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.90952 0.00018 SL = 1.9095188 +- 0.0001840 Tm^2/m^n 13:47:19 Magnet Strength Measurement Harmonic Number = 1 SL = 1.9095188 +- 0.0001840 Tm^2/m^n 13:47:20 Magnet Current, Imag = 600.1510 A Vtrans = 6.001510 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:47:22 Magnet Current, Imag = 600.1320 A Vtrans = 6.001320 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:47:24 Magnet Current, Imag = 600.1310 A Vtrans = 6.001310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:47:25 Magnet Current, Imag = 600.1370 A Vtrans = 6.001370 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:47:25 Magnet Current Measurement: Imag = 600.1377 +- 0.0080 A 13:47:26 Magnet current ramping to 550.0000 A... 13:47:49 Magnet Current, Imag = 550.1020 A Vtrans = 5.501020 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:47:51 Magnet Current, Imag = 550.0920 A Vtrans = 5.500920 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:47:52 Magnet Current, Imag = 550.0950 A Vtrans = 5.500950 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:47:54 Magnet Current, Imag = 550.1060 A Vtrans = 5.501060 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:47:54 Magnet Current Measurement: Imag = 550.0987 +- 0.0055 A 13:47:54 Magnetic Field Measurement Measuring the magnet strength... 13:47:54 Integrated Voltage Measurement... 13:48:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017547435 Vs 13:48:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017556287 Vs 13:48:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017548695 Vs 13:48:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017561421 Vs 13:48:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017544248 Vs 13:49:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017549971 Vs 13:49:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017539940 Vs 13:49:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017553009 Vs 13:49:23 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017550126 +- 0.000003527 Vs 13:49:23 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.017550126 +- 0.000003527 Vs BL = 1.75501258 +- 0.00035272 Tm 13:49:26 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.75501 0.00035 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.75501 0.00035 1.75501 0.00000 13:49:26 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.75501 0.00035 SL = 1.7550126 +- 0.0003527 Tm^2/m^n 13:49:26 Magnet Strength Measurement Harmonic Number = 1 SL = 1.7550126 +- 0.0003527 Tm^2/m^n 13:49:28 Magnet Current, Imag = 550.0990 A Vtrans = 5.500990 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:49:29 Magnet Current, Imag = 550.1080 A Vtrans = 5.501080 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:49:31 Magnet Current, Imag = 550.1170 A Vtrans = 5.501170 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:49:32 Magnet Current, Imag = 550.1100 A Vtrans = 5.501100 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:49:32 Magnet Current Measurement: Imag = 550.1085 +- 0.0064 A 13:49:33 Magnet current ramping to 500.0000 A... 13:49:56 Magnet Current, Imag = 500.1080 A Vtrans = 5.001080 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:49:58 Magnet Current, Imag = 500.1160 A Vtrans = 5.001160 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:49:59 Magnet Current, Imag = 500.1410 A Vtrans = 5.001410 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:50:01 Magnet Current, Imag = 500.1350 A Vtrans = 5.001350 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:50:01 Magnet Current Measurement: Imag = 500.1250 +- 0.0135 A 13:50:01 Magnetic Field Measurement Measuring the magnet strength... 13:50:01 Integrated Voltage Measurement... 13:50:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015963831 Vs 13:50:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015974048 Vs 13:50:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015968568 Vs 13:50:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015974152 Vs 13:50:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015978023 Vs 13:51:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015974035 Vs 13:51:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015953779 Vs 13:51:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015977027 Vs 13:51:30 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015970433 +- 0.000003863 Vs 13:51:30 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.015970433 +- 0.000003863 Vs BL = 1.59704330 +- 0.00038634 Tm 13:51:33 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.59704 0.00039 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.59704 0.00039 1.59704 0.00000 13:51:33 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.59704 0.00039 SL = 1.5970433 +- 0.0003863 Tm^2/m^n 13:51:33 Magnet Strength Measurement Harmonic Number = 1 SL = 1.5970433 +- 0.0003863 Tm^2/m^n 13:51:35 Magnet Current, Imag = 500.1310 A Vtrans = 5.001310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:51:36 Magnet Current, Imag = 500.1270 A Vtrans = 5.001270 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:51:38 Magnet Current, Imag = 500.1060 A Vtrans = 5.001060 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:51:39 Magnet Current, Imag = 500.1140 A Vtrans = 5.001140 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:51:39 Magnet Current Measurement: Imag = 500.1195 +- 0.0100 A 13:51:40 Magnet current ramping to 450.0000 A... 13:52:03 Magnet Current, Imag = 450.0650 A Vtrans = 4.500650 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:52:05 Magnet Current, Imag = 450.0760 A Vtrans = 4.500760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:52:06 Magnet Current, Imag = 450.0790 A Vtrans = 4.500790 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:52:08 Magnet Current, Imag = 450.0780 A Vtrans = 4.500780 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:52:08 Magnet Current Measurement: Imag = 450.0745 +- 0.0056 A 13:52:08 Magnetic Field Measurement Measuring the magnet strength... 13:52:08 Integrated Voltage Measurement... 13:52:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014377185 Vs 13:52:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014390853 Vs 13:52:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014382048 Vs 13:52:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014397277 Vs 13:53:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014376385 Vs 13:53:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014382823 Vs 13:53:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014386328 Vs 13:53:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014398265 Vs 13:53:37 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014386395 +- 0.000004931 Vs 13:53:37 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.014386395 +- 0.000004931 Vs BL = 1.43863954 +- 0.00049312 Tm 13:53:40 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.43864 0.00049 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.43864 0.00049 1.43864 0.00000 13:53:40 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.43864 0.00049 SL = 1.4386395 +- 0.0004931 Tm^2/m^n 13:53:40 Magnet Strength Measurement Harmonic Number = 1 SL = 1.4386395 +- 0.0004931 Tm^2/m^n 13:53:42 Magnet Current, Imag = 450.0700 A Vtrans = 4.500700 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:53:43 Magnet Current, Imag = 450.0710 A Vtrans = 4.500710 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:53:45 Magnet Current, Imag = 450.0660 A Vtrans = 4.500660 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:53:47 Magnet Current, Imag = 450.0510 A Vtrans = 4.500510 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:53:47 Magnet Current Measurement: Imag = 450.0645 +- 0.0080 A 13:53:47 Magnet current ramping to 400.0000 A... 13:54:10 Magnet Current, Imag = 400.0310 A Vtrans = 4.000310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:54:12 Magnet Current, Imag = 400.0430 A Vtrans = 4.000430 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:54:13 Magnet Current, Imag = 400.0490 A Vtrans = 4.000490 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:54:15 Magnet Current, Imag = 400.0210 A Vtrans = 4.000210 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:54:15 Magnet Current Measurement: Imag = 400.0360 +- 0.0108 A 13:54:15 Magnetic Field Measurement Measuring the magnet strength... 13:54:15 Integrated Voltage Measurement... 13:54:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012801555 Vs 13:54:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012800391 Vs 13:54:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012791284 Vs 13:55:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012782280 Vs 13:55:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012788633 Vs 13:55:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012789938 Vs 13:55:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012782439 Vs 13:55:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012796767 Vs 13:55:44 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012791661 +- 0.000005486 Vs 13:55:44 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.012791661 +- 0.000005486 Vs BL = 1.27916608 +- 0.00054863 Tm 13:55:47 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.27917 0.00055 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.27917 0.00055 1.27917 0.00000 13:55:47 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.27917 0.00055 SL = 1.2791661 +- 0.0005486 Tm^2/m^n 13:55:47 Magnet Strength Measurement Harmonic Number = 1 SL = 1.2791661 +- 0.0005486 Tm^2/m^n 13:55:49 Magnet Current, Imag = 400.0610 A Vtrans = 4.000610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:55:51 Magnet Current, Imag = 400.0490 A Vtrans = 4.000490 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:55:52 Magnet Current, Imag = 400.0440 A Vtrans = 4.000440 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:55:54 Magnet Current, Imag = 400.0420 A Vtrans = 4.000420 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:55:54 Magnet Current Measurement: Imag = 400.0490 +- 0.0074 A 13:56:24 Magnet current ramping to 0.0000 A...