SLAC Magnetic Measurements Date: 07-23-2001 Time: 15:05:04 Project: spear3 Magnet Type: gdipole Magnet Name: 145d-013 Serial Number: Run Number: 6 Measurement Device: stretched wire Operator: jy Comment: BL vs. I, mains Standardization: 1 cycles from 0.0 A to 770.0 A to 0.0 A Test Currents (A): 50.0 100.0 150.0 200.0 250.0 300.0 350.0 400.0 450.0 500.0 525.0 550.0 575.0 600.0 625.0 650.0 675.0 700.0 650.0 600.0 550.0 500.0 450.0 400.0 15:05:15 Initial Zero Current Measurement, Imag_zero = 0.0000 A 15:05:15 Magnet current ramping to 15.0000 A... 15:05:47 Magnet current ramping to 770.0000 A... 15:09:59 Magnet current ramping to 0.0000 A... 15:14:44 Magnet current ramping to 50.0000 A... 15:15:08 Magnet Current, Imag = 52.9790 A Vtrans = 0.529790 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:15:09 Magnet Current, Imag = 53.7259 A Vtrans = 0.537259 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:15:11 Magnet Current, Imag = 47.4291 A Vtrans = 0.474291 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:15:12 Magnet Current, Imag = 49.5505 A Vtrans = 0.495505 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:15:12 Magnet Current Measurement: Imag = 50.9211 +- 2.5580 A 15:15:13 Magnetic Field Measurement Measuring the magnet strength... 15:15:13 Integrated Voltage Measurement... 15:15:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001582116 Vs 15:15:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001605868 Vs 15:15:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001594315 Vs 15:15:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001605006 Vs 15:16:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001597677 Vs 15:16:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001607479 Vs 15:16:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001594200 Vs 15:16:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001597159 Vs 15:16:40 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001597977 +- 0.000003360 Vs 15:16:40 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.001597977 +- 0.000003360 Vs BL = 0.15979775 +- 0.00033603 Tm 15:16:44 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.15980 0.00034 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.15980 0.00034 0.15980 0.00000 15:16:44 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.15980 0.00034 SL = 0.1597977 +- 0.0003360 Tm^2/m^n 15:16:44 Magnet Strength Measurement Harmonic Number = 1 SL = 0.1597977 +- 0.0003360 Tm^2/m^n 15:16:45 Magnet Current, Imag = 49.9026 A Vtrans = 0.499026 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:16:47 Magnet Current, Imag = 49.8864 A Vtrans = 0.498864 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:16:48 Magnet Current, Imag = 49.8860 A Vtrans = 0.498860 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:16:50 Magnet Current, Imag = 49.8827 A Vtrans = 0.498827 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:16:50 Magnet Current Measurement: Imag = 49.8894 +- 0.0077 A 15:16:50 Magnet current ramping to 100.0000 A... 15:17:13 Magnet Current, Imag = 99.9408 A Vtrans = 0.999408 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:17:14 Magnet Current, Imag = 99.9041 A Vtrans = 0.999041 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:17:16 Magnet Current, Imag = 99.9052 A Vtrans = 0.999052 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:17:17 Magnet Current, Imag = 99.9231 A Vtrans = 0.999231 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:17:17 Magnet Current Measurement: Imag = 99.9183 +- 0.0150 A 15:17:17 Magnetic Field Measurement Measuring the magnet strength... 15:17:17 Integrated Voltage Measurement... 15:17:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003177425 Vs 15:17:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003185878 Vs 15:17:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003171348 Vs 15:18:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003178134 Vs 15:18:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003174138 Vs 15:18:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003184032 Vs 15:18:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003171370 Vs 15:18:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003181903 Vs 15:18:45 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003178029 +- 0.000002598 Vs 15:18:45 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.003178029 +- 0.000002598 Vs BL = 0.31780285 +- 0.00025976 Tm 15:18:48 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.31780 0.00026 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.31780 0.00026 0.31780 0.00000 15:18:48 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.31780 0.00026 SL = 0.3178028 +- 0.0002598 Tm^2/m^n 15:18:48 Magnet Strength Measurement Harmonic Number = 1 SL = 0.3178028 +- 0.0002598 Tm^2/m^n 15:18:50 Magnet Current, Imag = 99.9203 A Vtrans = 0.999203 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:18:51 Magnet Current, Imag = 99.9205 A Vtrans = 0.999205 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:18:53 Magnet Current, Imag = 99.9242 A Vtrans = 0.999242 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:18:54 Magnet Current, Imag = 99.9310 A Vtrans = 0.999310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:18:54 Magnet Current Measurement: Imag = 99.9240 +- 0.0043 A 15:18:54 Magnet current ramping to 150.0000 A... 15:19:17 Magnet Current, Imag = 149.9373 A Vtrans = 1.499373 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:19:19 Magnet Current, Imag = 149.9469 A Vtrans = 1.499469 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:19:20 Magnet Current, Imag = 149.9632 A Vtrans = 1.499632 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:19:22 Magnet Current, Imag = 149.9586 A Vtrans = 1.499586 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:19:22 Magnet Current Measurement: Imag = 149.9515 +- 0.0101 A 15:19:22 Magnetic Field Measurement Measuring the magnet strength... 15:19:22 Integrated Voltage Measurement... 15:19:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004763487 Vs 15:19:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004777133 Vs 15:19:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004768911 Vs 15:20:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004769507 Vs 15:20:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004767708 Vs 15:20:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004775448 Vs 15:20:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004764989 Vs 15:20:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004767347 Vs 15:20:50 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004769316 +- 0.000002002 Vs 15:20:50 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.004769316 +- 0.000002002 Vs BL = 0.47693162 +- 0.00020016 Tm 15:20:53 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.47693 0.00020 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.47693 0.00020 0.47693 0.00000 15:20:53 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.47693 0.00020 SL = 0.4769316 +- 0.0002002 Tm^2/m^n 15:20:53 Magnet Strength Measurement Harmonic Number = 1 SL = 0.4769316 +- 0.0002002 Tm^2/m^n 15:20:55 Magnet Current, Imag = 149.9391 A Vtrans = 1.499391 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:20:56 Magnet Current, Imag = 149.9258 A Vtrans = 1.499258 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:20:58 Magnet Current, Imag = 149.9619 A Vtrans = 1.499619 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:20:59 Magnet Current, Imag = 149.9584 A Vtrans = 1.499584 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:20:59 Magnet Current Measurement: Imag = 149.9463 +- 0.0147 A 15:21:00 Magnet current ramping to 200.0000 A... 15:21:22 Magnet Current, Imag = 199.9407 A Vtrans = 1.999407 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:21:24 Magnet Current, Imag = 199.9640 A Vtrans = 1.999640 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:21:25 Magnet Current, Imag = 199.9499 A Vtrans = 1.999499 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:21:27 Magnet Current, Imag = 199.9586 A Vtrans = 1.999586 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:21:27 Magnet Current Measurement: Imag = 199.9533 +- 0.0088 A 15:21:27 Magnetic Field Measurement Measuring the magnet strength... 15:21:27 Integrated Voltage Measurement... 15:21:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006354372 Vs 15:21:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006361927 Vs 15:22:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006358385 Vs 15:22:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006361229 Vs 15:22:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006353021 Vs 15:22:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006364565 Vs 15:22:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006352394 Vs 15:22:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006404411 Vs 15:22:54 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006363788 +- 0.000008458 Vs 15:22:55 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.006363788 +- 0.000008458 Vs BL = 0.63637880 +- 0.00084584 Tm 15:22:58 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.63638 0.00085 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.63638 0.00085 0.63638 0.00000 15:22:58 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.63638 0.00085 SL = 0.6363788 +- 0.0008458 Tm^2/m^n 15:22:58 Magnet Strength Measurement Harmonic Number = 1 SL = 0.6363788 +- 0.0008458 Tm^2/m^n 15:22:59 Magnet Current, Imag = 199.9374 A Vtrans = 1.999374 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:23:01 Magnet Current, Imag = 199.9437 A Vtrans = 1.999437 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:23:02 Magnet Current, Imag = 199.9338 A Vtrans = 1.999338 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:23:04 Magnet Current, Imag = 199.9377 A Vtrans = 1.999377 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:23:04 Magnet Current Measurement: Imag = 199.9381 +- 0.0036 A 15:23:04 Magnet current ramping to 250.0000 A... 15:23:27 Magnet Current, Imag = 249.9530 A Vtrans = 2.499530 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:23:28 Magnet Current, Imag = 249.9616 A Vtrans = 2.499616 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:23:30 Magnet Current, Imag = 249.9739 A Vtrans = 2.499739 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:23:31 Magnet Current, Imag = 249.9610 A Vtrans = 2.499610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:23:31 Magnet Current Measurement: Imag = 249.9624 +- 0.0075 A 15:23:31 Magnetic Field Measurement Measuring the magnet strength... 15:23:32 Integrated Voltage Measurement... 15:23:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007958971 Vs 15:23:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007959903 Vs 15:24:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007942310 Vs 15:24:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007946991 Vs 15:24:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007951396 Vs 15:24:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007961217 Vs 15:24:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007937049 Vs 15:24:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007945361 Vs 15:24:59 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007950400 +- 0.000007651 Vs 15:24:59 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.007950400 +- 0.000007651 Vs BL = 0.79503996 +- 0.00076512 Tm 15:25:02 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.79504 0.00077 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.79504 0.00077 0.79504 0.00000 15:25:02 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.79504 0.00077 SL = 0.7950400 +- 0.0007651 Tm^2/m^n 15:25:03 Magnet Strength Measurement Harmonic Number = 1 SL = 0.7950400 +- 0.0007651 Tm^2/m^n 15:25:04 Magnet Current, Imag = 249.9525 A Vtrans = 2.499525 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:25:06 Magnet Current, Imag = 249.9633 A Vtrans = 2.499633 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:25:07 Magnet Current, Imag = 249.9581 A Vtrans = 2.499581 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:25:09 Magnet Current, Imag = 249.9549 A Vtrans = 2.499549 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:25:09 Magnet Current Measurement: Imag = 249.9572 +- 0.0040 A 15:25:09 Magnet current ramping to 300.0000 A... 15:25:32 Magnet Current, Imag = 299.9968 A Vtrans = 2.999968 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:25:33 Magnet Current, Imag = 300.0207 A Vtrans = 3.000207 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:25:35 Magnet Current, Imag = 300.0083 A Vtrans = 3.000083 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:25:36 Magnet Current, Imag = 300.0050 A Vtrans = 3.000050 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:25:36 Magnet Current Measurement: Imag = 300.0077 +- 0.0086 A 15:25:36 Magnetic Field Measurement Measuring the magnet strength... 15:25:36 Integrated Voltage Measurement... 15:25:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009546735 Vs 15:26:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009542164 Vs 15:26:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009534657 Vs 15:26:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009543023 Vs 15:26:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009542674 Vs 15:26:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009545336 Vs 15:26:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009540182 Vs 15:27:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009547123 Vs 15:27:04 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009542737 +- 0.000002268 Vs 15:27:05 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.009542737 +- 0.000002268 Vs BL = 0.95427367 +- 0.00022676 Tm 15:27:08 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.95427 0.00023 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.95427 0.00023 0.95427 0.00000 15:27:08 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.95427 0.00023 SL = 0.9542737 +- 0.0002268 Tm^2/m^n 15:27:08 Magnet Strength Measurement Harmonic Number = 1 SL = 0.9542737 +- 0.0002268 Tm^2/m^n 15:27:09 Magnet Current, Imag = 300.0070 A Vtrans = 3.000070 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:27:11 Magnet Current, Imag = 300.0031 A Vtrans = 3.000031 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:27:12 Magnet Current, Imag = 300.0127 A Vtrans = 3.000127 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:27:14 Magnet Current, Imag = 300.0046 A Vtrans = 3.000046 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:27:14 Magnet Current Measurement: Imag = 300.0068 +- 0.0037 A 15:27:14 Magnet current ramping to 350.0000 A... 15:27:37 Magnet Current, Imag = 350.0550 A Vtrans = 3.500550 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:27:39 Magnet Current, Imag = 350.0450 A Vtrans = 3.500450 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:27:41 Magnet Current, Imag = 350.0260 A Vtrans = 3.500260 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:27:43 Magnet Current, Imag = 350.0330 A Vtrans = 3.500330 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:27:43 Magnet Current Measurement: Imag = 350.0397 +- 0.0111 A 15:27:43 Magnetic Field Measurement Measuring the magnet strength... 15:27:43 Integrated Voltage Measurement... 15:27:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011127572 Vs 15:28:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011143457 Vs 15:28:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011131427 Vs 15:28:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011141130 Vs 15:28:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011128829 Vs 15:28:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011139668 Vs 15:29:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011132480 Vs 15:29:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011139613 Vs 15:29:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011135522 +- 0.000000786 Vs 15:29:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.011135522 +- 0.000000786 Vs BL = 1.11355221 +- 0.00007858 Tm 15:29:14 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.11355 0.00008 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.11355 0.00008 1.11355 0.00000 15:29:14 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.11355 0.00008 SL = 1.1135522 +- 0.0000786 Tm^2/m^n 15:29:14 Magnet Strength Measurement Harmonic Number = 1 SL = 1.1135522 +- 0.0000786 Tm^2/m^n 15:29:16 Magnet Current, Imag = 350.0370 A Vtrans = 3.500370 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:29:18 Magnet Current, Imag = 350.0420 A Vtrans = 3.500420 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:29:20 Magnet Current, Imag = 350.0440 A Vtrans = 3.500440 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:29:22 Magnet Current, Imag = 350.0450 A Vtrans = 3.500450 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:29:22 Magnet Current Measurement: Imag = 350.0420 +- 0.0031 A 15:29:22 Magnet current ramping to 400.0000 A... 15:29:46 Magnet Current, Imag = 400.0410 A Vtrans = 4.000410 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:29:47 Magnet Current, Imag = 400.0560 A Vtrans = 4.000560 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:29:49 Magnet Current, Imag = 400.0410 A Vtrans = 4.000410 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:29:51 Magnet Current, Imag = 400.0570 A Vtrans = 4.000570 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:29:51 Magnet Current Measurement: Imag = 400.0487 +- 0.0078 A 15:29:51 Magnetic Field Measurement Measuring the magnet strength... 15:29:51 Integrated Voltage Measurement... 15:30:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012703809 Vs 15:30:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012719656 Vs 15:30:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012727983 Vs 15:30:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012731197 Vs 15:30:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012714407 Vs 15:30:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012727975 Vs 15:31:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012731989 Vs 15:31:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012726784 Vs 15:31:19 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012722975 +- 0.000007322 Vs 15:31:19 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.012722975 +- 0.000007322 Vs BL = 1.27229748 +- 0.00073219 Tm 15:31:22 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.27230 0.00073 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.27230 0.00073 1.27230 0.00000 15:31:22 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.27230 0.00073 SL = 1.2722975 +- 0.0007322 Tm^2/m^n 15:31:22 Magnet Strength Measurement Harmonic Number = 1 SL = 1.2722975 +- 0.0007322 Tm^2/m^n 15:31:24 Magnet Current, Imag = 400.0520 A Vtrans = 4.000520 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:31:25 Magnet Current, Imag = 400.0600 A Vtrans = 4.000600 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:31:27 Magnet Current, Imag = 400.0570 A Vtrans = 4.000570 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:31:28 Magnet Current, Imag = 400.0500 A Vtrans = 4.000500 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:31:29 Magnet Current Measurement: Imag = 400.0547 +- 0.0040 A 15:31:29 Magnet current ramping to 450.0000 A... 15:31:52 Magnet Current, Imag = 450.0440 A Vtrans = 4.500440 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:31:53 Magnet Current, Imag = 450.0480 A Vtrans = 4.500480 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:31:55 Magnet Current, Imag = 450.0530 A Vtrans = 4.500530 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:31:56 Magnet Current, Imag = 450.0570 A Vtrans = 4.500570 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:31:57 Magnet Current Measurement: Imag = 450.0505 +- 0.0049 A 15:31:57 Magnetic Field Measurement Measuring the magnet strength... 15:31:57 Integrated Voltage Measurement... 15:32:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014311135 Vs 15:32:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014329759 Vs 15:32:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014315631 Vs 15:32:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014318825 Vs 15:32:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014303679 Vs 15:33:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014315891 Vs 15:33:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014300241 Vs 15:33:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014315052 Vs 15:33:25 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014313777 +- 0.000005242 Vs 15:33:25 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.014313777 +- 0.000005242 Vs BL = 1.43137767 +- 0.00052422 Tm 15:33:28 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.43138 0.00052 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.43138 0.00052 1.43138 0.00000 15:33:28 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.43138 0.00052 SL = 1.4313777 +- 0.0005242 Tm^2/m^n 15:33:28 Magnet Strength Measurement Harmonic Number = 1 SL = 1.4313777 +- 0.0005242 Tm^2/m^n 15:33:29 Magnet Current, Imag = 450.0640 A Vtrans = 4.500640 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:33:31 Magnet Current, Imag = 450.0760 A Vtrans = 4.500760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:33:33 Magnet Current, Imag = 450.0740 A Vtrans = 4.500740 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:33:34 Magnet Current, Imag = 450.0850 A Vtrans = 4.500850 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:33:34 Magnet Current Measurement: Imag = 450.0747 +- 0.0075 A 15:33:35 Magnet current ramping to 500.0000 A... 15:33:58 Magnet Current, Imag = 500.1140 A Vtrans = 5.001140 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:33:59 Magnet Current, Imag = 500.1440 A Vtrans = 5.001440 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:34:01 Magnet Current, Imag = 500.1290 A Vtrans = 5.001290 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:34:02 Magnet Current, Imag = 500.1330 A Vtrans = 5.001330 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:34:02 Magnet Current Measurement: Imag = 500.1300 +- 0.0107 A 15:34:03 Magnetic Field Measurement Measuring the magnet strength... 15:34:03 Integrated Voltage Measurement... 15:34:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015889319 Vs 15:34:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015896624 Vs 15:34:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015903679 Vs 15:34:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015898150 Vs 15:34:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015886895 Vs 15:35:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015911680 Vs 15:35:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015897637 Vs 15:35:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015905360 Vs 15:35:31 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015898668 +- 0.000003387 Vs 15:35:31 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.015898668 +- 0.000003387 Vs BL = 1.58986680 +- 0.00033873 Tm 15:35:34 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.58987 0.00034 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.58987 0.00034 1.58987 0.00000 15:35:34 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.58987 0.00034 SL = 1.5898668 +- 0.0003387 Tm^2/m^n 15:35:34 Magnet Strength Measurement Harmonic Number = 1 SL = 1.5898668 +- 0.0003387 Tm^2/m^n 15:35:35 Magnet Current, Imag = 500.1170 A Vtrans = 5.001170 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:35:37 Magnet Current, Imag = 500.1010 A Vtrans = 5.001010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:35:39 Magnet Current, Imag = 500.0930 A Vtrans = 5.000930 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:35:40 Magnet Current, Imag = 500.0900 A Vtrans = 5.000900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:35:40 Magnet Current Measurement: Imag = 500.1003 +- 0.0105 A 15:35:41 Magnet current ramping to 525.0000 A... 15:35:56 Magnet Current, Imag = 525.1350 A Vtrans = 5.251350 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:35:58 Magnet Current, Imag = 525.1400 A Vtrans = 5.251400 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:36:00 Magnet Current, Imag = 525.1340 A Vtrans = 5.251340 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:36:01 Magnet Current, Imag = 525.1300 A Vtrans = 5.251300 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:36:01 Magnet Current Measurement: Imag = 525.1347 +- 0.0036 A 15:36:01 Magnetic Field Measurement Measuring the magnet strength... 15:36:01 Integrated Voltage Measurement... 15:36:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016695460 Vs 15:36:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016697641 Vs 15:36:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016681007 Vs 15:36:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016701999 Vs 15:36:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016677536 Vs 15:37:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016687303 Vs 15:37:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016677709 Vs 15:37:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016698559 Vs 15:37:30 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016689652 +- 0.000005139 Vs 15:37:30 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.016689652 +- 0.000005139 Vs BL = 1.66896517 +- 0.00051388 Tm 15:37:33 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.66897 0.00051 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.66897 0.00051 1.66897 0.00000 15:37:33 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.66897 0.00051 SL = 1.6689652 +- 0.0005139 Tm^2/m^n 15:37:33 Magnet Strength Measurement Harmonic Number = 1 SL = 1.6689652 +- 0.0005139 Tm^2/m^n 15:37:35 Magnet Current, Imag = 525.1320 A Vtrans = 5.251320 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:37:36 Magnet Current, Imag = 525.1280 A Vtrans = 5.251280 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:37:38 Magnet Current, Imag = 525.1260 A Vtrans = 5.251260 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:37:39 Magnet Current, Imag = 525.1380 A Vtrans = 5.251380 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:37:40 Magnet Current Measurement: Imag = 525.1310 +- 0.0046 A 15:37:40 Magnet current ramping to 550.0000 A... 15:37:55 Magnet Current, Imag = 550.0910 A Vtrans = 5.500910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:37:57 Magnet Current, Imag = 550.1030 A Vtrans = 5.501030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:37:59 Magnet Current, Imag = 550.1200 A Vtrans = 5.501200 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:38:00 Magnet Current, Imag = 550.1240 A Vtrans = 5.501240 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:38:00 Magnet Current Measurement: Imag = 550.1095 +- 0.0133 A 15:38:00 Magnetic Field Measurement Measuring the magnet strength... 15:38:01 Integrated Voltage Measurement... 15:38:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017450260 Vs 15:38:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017626773 Vs 15:38:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017466730 Vs 15:38:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017457803 Vs 15:38:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017465729 Vs 15:39:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017479287 Vs 15:39:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017447096 Vs 15:39:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017469941 Vs 15:39:28 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017482952 +- 0.000032486 Vs 15:39:29 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.017482952 +- 0.000032486 Vs BL = 1.74829524 +- 0.00324861 Tm 15:39:32 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.74830 0.00325 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.74830 0.00325 1.74830 0.00000 15:39:32 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.74830 0.00325 SL = 1.7482952 +- 0.0032486 Tm^2/m^n 15:39:32 Magnet Strength Measurement Harmonic Number = 1 SL = 1.7482952 +- 0.0032486 Tm^2/m^n 15:39:33 Magnet Current, Imag = 550.0930 A Vtrans = 5.500930 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:39:36 Magnet Current, Imag = 550.1060 A Vtrans = 5.501060 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:39:37 Magnet Current, Imag = 550.1030 A Vtrans = 5.501030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:39:39 Magnet Current, Imag = 550.1150 A Vtrans = 5.501150 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:39:39 Magnet Current Measurement: Imag = 550.1043 +- 0.0079 A 15:39:39 Magnet current ramping to 575.0000 A... 15:39:55 Magnet Current, Imag = 575.0980 A Vtrans = 5.750980 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:39:57 Magnet Current, Imag = 575.1020 A Vtrans = 5.751020 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:39:58 Magnet Current, Imag = 575.1180 A Vtrans = 5.751180 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:40:00 Magnet Current, Imag = 575.1170 A Vtrans = 5.751170 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:40:00 Magnet Current Measurement: Imag = 575.1087 +- 0.0089 A 15:40:00 Magnetic Field Measurement Measuring the magnet strength... 15:40:00 Integrated Voltage Measurement... 15:40:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018231124 Vs 15:40:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018238767 Vs 15:40:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018234387 Vs 15:40:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018247995 Vs 15:40:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018234254 Vs 15:41:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018238021 Vs 15:41:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018246711 Vs 15:41:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018239315 Vs 15:41:28 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018238822 +- 0.000003369 Vs 15:41:28 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.018238822 +- 0.000003369 Vs BL = 1.82388218 +- 0.00033692 Tm 15:41:31 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.82388 0.00034 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.82388 0.00034 1.82388 0.00000 15:41:32 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.82388 0.00034 SL = 1.8238822 +- 0.0003369 Tm^2/m^n 15:41:32 Magnet Strength Measurement Harmonic Number = 1 SL = 1.8238822 +- 0.0003369 Tm^2/m^n 15:41:33 Magnet Current, Imag = 575.1290 A Vtrans = 5.751290 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:41:35 Magnet Current, Imag = 575.1190 A Vtrans = 5.751190 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:41:36 Magnet Current, Imag = 575.1100 A Vtrans = 5.751100 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:41:38 Magnet Current, Imag = 575.1150 A Vtrans = 5.751150 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:41:38 Magnet Current Measurement: Imag = 575.1182 +- 0.0070 A 15:41:38 Magnet current ramping to 600.0000 A... 15:41:54 Magnet Current, Imag = 600.1500 A Vtrans = 6.001500 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:41:55 Magnet Current, Imag = 600.1530 A Vtrans = 6.001530 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:41:57 Magnet Current, Imag = 600.1460 A Vtrans = 6.001460 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:41:59 Magnet Current, Imag = 600.1510 A Vtrans = 6.001510 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:41:59 Magnet Current Measurement: Imag = 600.1500 +- 0.0025 A 15:41:59 Magnetic Field Measurement Measuring the magnet strength... 15:41:59 Integrated Voltage Measurement... 15:42:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018990057 Vs 15:42:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019007391 Vs 15:42:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018989495 Vs 15:42:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019010444 Vs 15:42:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019000195 Vs 15:43:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019011755 Vs 15:43:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018989701 Vs 15:43:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018995463 Vs 15:43:27 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018999313 +- 0.000004756 Vs 15:43:27 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.018999313 +- 0.000004756 Vs BL = 1.89993127 +- 0.00047558 Tm 15:43:30 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.89993 0.00048 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.89993 0.00048 1.89993 0.00000 15:43:30 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.89993 0.00048 SL = 1.8999313 +- 0.0004756 Tm^2/m^n 15:43:30 Magnet Strength Measurement Harmonic Number = 1 SL = 1.8999313 +- 0.0004756 Tm^2/m^n 15:43:32 Magnet Current, Imag = 600.1380 A Vtrans = 6.001380 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:43:33 Magnet Current, Imag = 600.1310 A Vtrans = 6.001310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:43:35 Magnet Current, Imag = 600.1150 A Vtrans = 6.001150 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:43:37 Magnet Current, Imag = 600.1170 A Vtrans = 6.001170 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:43:37 Magnet Current Measurement: Imag = 600.1253 +- 0.0096 A 15:43:37 Magnet current ramping to 625.0000 A... 15:43:53 Magnet Current, Imag = 625.1960 A Vtrans = 6.251960 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:43:54 Magnet Current, Imag = 625.1990 A Vtrans = 6.251990 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:43:56 Magnet Current, Imag = 625.1830 A Vtrans = 6.251830 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:43:57 Magnet Current, Imag = 625.1750 A Vtrans = 6.251750 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:43:57 Magnet Current Measurement: Imag = 625.1882 +- 0.0097 A 15:43:58 Magnetic Field Measurement Measuring the magnet strength... 15:43:58 Integrated Voltage Measurement... 15:44:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019729015 Vs 15:44:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019738552 Vs 15:44:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019734695 Vs 15:44:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019739429 Vs 15:44:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019730387 Vs 15:45:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019746299 Vs 15:45:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019732690 Vs 15:45:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019741525 Vs 15:45:26 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019736574 +- 0.000001691 Vs 15:45:26 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.019736574 +- 0.000001691 Vs BL = 1.97365741 +- 0.00016910 Tm 15:45:29 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.97366 0.00017 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.97366 0.00017 1.97366 0.00000 15:45:29 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.97366 0.00017 SL = 1.9736574 +- 0.0001691 Tm^2/m^n 15:45:29 Magnet Strength Measurement Harmonic Number = 1 SL = 1.9736574 +- 0.0001691 Tm^2/m^n 15:45:31 Magnet Current, Imag = 625.1850 A Vtrans = 6.251850 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:45:32 Magnet Current, Imag = 625.1760 A Vtrans = 6.251760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:45:34 Magnet Current, Imag = 625.1830 A Vtrans = 6.251830 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:45:35 Magnet Current, Imag = 625.1720 A Vtrans = 6.251720 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:45:35 Magnet Current Measurement: Imag = 625.1790 +- 0.0052 A 15:45:36 Magnet current ramping to 650.0000 A... 15:45:51 Magnet Current, Imag = 650.2190 A Vtrans = 6.502190 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:45:53 Magnet Current, Imag = 650.2090 A Vtrans = 6.502090 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:45:54 Magnet Current, Imag = 650.1950 A Vtrans = 6.501950 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:45:56 Magnet Current, Imag = 650.1940 A Vtrans = 6.501940 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:45:56 Magnet Current Measurement: Imag = 650.2043 +- 0.0104 A 15:45:56 Magnetic Field Measurement Measuring the magnet strength... 15:45:56 Integrated Voltage Measurement... 15:46:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020440539 Vs 15:46:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020457408 Vs 15:46:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020434048 Vs 15:46:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020448825 Vs 15:46:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020441696 Vs 15:47:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020446721 Vs 15:47:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020440661 Vs 15:47:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020448975 Vs 15:47:24 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020444859 +- 0.000002696 Vs 15:47:24 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.020444859 +- 0.000002696 Vs BL = 2.04448592 +- 0.00026957 Tm 15:47:27 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.04449 0.00027 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.04449 0.00027 2.04449 0.00000 15:47:28 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.04449 0.00027 SL = 2.0444859 +- 0.0002696 Tm^2/m^n 15:47:28 Magnet Strength Measurement Harmonic Number = 1 SL = 2.0444859 +- 0.0002696 Tm^2/m^n 15:47:29 Magnet Current, Imag = 650.1950 A Vtrans = 6.501950 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:31 Magnet Current, Imag = 650.1920 A Vtrans = 6.501920 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:32 Magnet Current, Imag = 650.1990 A Vtrans = 6.501990 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:34 Magnet Current, Imag = 650.1990 A Vtrans = 6.501990 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:34 Magnet Current Measurement: Imag = 650.1962 +- 0.0029 A 15:47:34 Magnet current ramping to 675.0000 A... 15:47:50 Magnet Current, Imag = 675.1830 A Vtrans = 6.751830 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:52 Magnet Current, Imag = 675.1930 A Vtrans = 6.751930 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:53 Magnet Current, Imag = 675.1950 A Vtrans = 6.751950 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:55 Magnet Current, Imag = 675.1970 A Vtrans = 6.751970 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:55 Magnet Current Measurement: Imag = 675.1920 +- 0.0054 A 15:47:55 Magnetic Field Measurement Measuring the magnet strength... 15:47:55 Integrated Voltage Measurement... 15:48:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021098231 Vs 15:48:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021119573 Vs 15:48:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021098179 Vs 15:48:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021111531 Vs 15:48:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021096855 Vs 15:49:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021111109 Vs 15:49:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021109405 Vs 15:49:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021110522 Vs 15:49:23 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021106926 +- 0.000002554 Vs 15:49:23 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.021106926 +- 0.000002554 Vs BL = 2.11069256 +- 0.00025537 Tm 15:49:26 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.11069 0.00026 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.11069 0.00026 2.11069 0.00000 15:49:26 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.11069 0.00026 SL = 2.1106926 +- 0.0002554 Tm^2/m^n 15:49:26 Magnet Strength Measurement Harmonic Number = 1 SL = 2.1106926 +- 0.0002554 Tm^2/m^n 15:49:28 Magnet Current, Imag = 675.2050 A Vtrans = 6.752050 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:49:29 Magnet Current, Imag = 675.1950 A Vtrans = 6.751950 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:49:31 Magnet Current, Imag = 675.2040 A Vtrans = 6.752040 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:49:32 Magnet Current, Imag = 675.1910 A Vtrans = 6.751910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:49:32 Magnet Current Measurement: Imag = 675.1987 +- 0.0059 A 15:49:33 Magnet current ramping to 700.0000 A... 15:49:48 Magnet Current, Imag = 700.2240 A Vtrans = 7.002240 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:49:50 Magnet Current, Imag = 700.2010 A Vtrans = 7.002010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:49:52 Magnet Current, Imag = 700.2240 A Vtrans = 7.002240 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:49:53 Magnet Current, Imag = 700.2110 A Vtrans = 7.002110 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:49:53 Magnet Current Measurement: Imag = 700.2150 +- 0.0097 A 15:49:53 Magnetic Field Measurement Measuring the magnet strength... 15:49:53 Integrated Voltage Measurement... 15:50:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021716227 Vs 15:50:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021720909 Vs 15:50:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021716918 Vs 15:50:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021734489 Vs 15:50:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021714948 Vs 15:51:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021727865 Vs 15:51:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021720796 Vs 15:51:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021729396 Vs 15:51:21 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021722694 +- 0.000002894 Vs 15:51:21 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.021722694 +- 0.000002894 Vs BL = 2.17226936 +- 0.00028943 Tm 15:51:24 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.17227 0.00029 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.17227 0.00029 2.17227 0.00000 15:51:25 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.17227 0.00029 SL = 2.1722694 +- 0.0002894 Tm^2/m^n 15:51:25 Magnet Strength Measurement Harmonic Number = 1 SL = 2.1722694 +- 0.0002894 Tm^2/m^n 15:51:26 Magnet Current, Imag = 700.1920 A Vtrans = 7.001920 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:51:28 Magnet Current, Imag = 700.1980 A Vtrans = 7.001980 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:51:29 Magnet Current, Imag = 700.2100 A Vtrans = 7.002100 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:51:31 Magnet Current, Imag = 700.2330 A Vtrans = 7.002330 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:51:31 Magnet Current Measurement: Imag = 700.2082 +- 0.0157 A 15:51:31 Magnet current ramping to 650.0000 A... 15:51:54 Magnet Current, Imag = 650.1820 A Vtrans = 6.501820 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:51:56 Magnet Current, Imag = 650.1920 A Vtrans = 6.501920 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:51:58 Magnet Current, Imag = 650.1900 A Vtrans = 6.501900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:51:59 Magnet Current, Imag = 650.1860 A Vtrans = 6.501860 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:51:59 Magnet Current Measurement: Imag = 650.1875 +- 0.0038 A 15:51:59 Magnetic Field Measurement Measuring the magnet strength... 15:51:59 Integrated Voltage Measurement... 15:52:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020517156 Vs 15:52:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020523169 Vs 15:52:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020519129 Vs 15:52:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020535106 Vs 15:52:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020514773 Vs 15:53:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020539368 Vs 15:53:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020521543 Vs 15:53:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020530956 Vs 15:53:27 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020525150 +- 0.000002900 Vs 15:53:28 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.020525150 +- 0.000002900 Vs BL = 2.05251501 +- 0.00029001 Tm 15:53:31 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.05252 0.00029 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.05252 0.00029 2.05252 0.00000 15:53:31 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.05252 0.00029 SL = 2.0525150 +- 0.0002900 Tm^2/m^n 15:53:31 Magnet Strength Measurement Harmonic Number = 1 SL = 2.0525150 +- 0.0002900 Tm^2/m^n 15:53:32 Magnet Current, Imag = 650.1810 A Vtrans = 6.501810 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:53:34 Magnet Current, Imag = 650.1670 A Vtrans = 6.501670 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:53:36 Magnet Current, Imag = 650.1750 A Vtrans = 6.501750 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:53:37 Magnet Current, Imag = 650.1630 A Vtrans = 6.501630 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:53:37 Magnet Current Measurement: Imag = 650.1715 +- 0.0070 A 15:53:38 Magnet current ramping to 600.0000 A... 15:54:01 Magnet Current, Imag = 600.1290 A Vtrans = 6.001290 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:54:02 Magnet Current, Imag = 600.1440 A Vtrans = 6.001440 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:54:04 Magnet Current, Imag = 600.1160 A Vtrans = 6.001160 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:54:05 Magnet Current, Imag = 600.1170 A Vtrans = 6.001170 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:54:05 Magnet Current Measurement: Imag = 600.1265 +- 0.0113 A 15:54:06 Magnetic Field Measurement Measuring the magnet strength... 15:54:06 Integrated Voltage Measurement... 15:54:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019071689 Vs 15:54:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019087883 Vs 15:54:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019082555 Vs 15:54:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019083125 Vs 15:55:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019073007 Vs 15:55:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019092504 Vs 15:55:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019071063 Vs 15:55:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019095247 Vs 15:55:33 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019082134 +- 0.000001364 Vs 15:55:34 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.019082134 +- 0.000001364 Vs BL = 1.90821340 +- 0.00013638 Tm 15:55:37 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.90821 0.00014 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.90821 0.00014 1.90821 0.00000 15:55:37 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.90821 0.00014 SL = 1.9082134 +- 0.0001364 Tm^2/m^n 15:55:37 Magnet Strength Measurement Harmonic Number = 1 SL = 1.9082134 +- 0.0001364 Tm^2/m^n 15:55:38 Magnet Current, Imag = 600.1490 A Vtrans = 6.001490 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:55:40 Magnet Current, Imag = 600.1620 A Vtrans = 6.001620 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:55:42 Magnet Current, Imag = 600.1700 A Vtrans = 6.001700 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:55:43 Magnet Current, Imag = 600.1490 A Vtrans = 6.001490 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:55:43 Magnet Current Measurement: Imag = 600.1575 +- 0.0090 A 15:55:44 Magnet current ramping to 550.0000 A... 15:56:07 Magnet Current, Imag = 550.1390 A Vtrans = 5.501390 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:56:08 Magnet Current, Imag = 550.1350 A Vtrans = 5.501350 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:56:10 Magnet Current, Imag = 550.1260 A Vtrans = 5.501260 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:56:11 Magnet Current, Imag = 550.1230 A Vtrans = 5.501230 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:56:11 Magnet Current Measurement: Imag = 550.1307 +- 0.0065 A 15:56:12 Magnetic Field Measurement Measuring the magnet strength... 15:56:12 Integrated Voltage Measurement... 15:56:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017527144 Vs 15:56:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017551257 Vs 15:56:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017529996 Vs 15:56:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017539384 Vs 15:57:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017530063 Vs 15:57:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017543165 Vs 15:57:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017526952 Vs 15:57:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017535797 Vs 15:57:40 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017535470 +- 0.000002855 Vs 15:57:40 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.017535470 +- 0.000002855 Vs BL = 1.75354698 +- 0.00028550 Tm 15:57:43 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.75355 0.00029 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.75355 0.00029 1.75355 0.00000 15:57:43 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.75355 0.00029 SL = 1.7535470 +- 0.0002855 Tm^2/m^n 15:57:43 Magnet Strength Measurement Harmonic Number = 1 SL = 1.7535470 +- 0.0002855 Tm^2/m^n 15:57:45 Magnet Current, Imag = 550.1190 A Vtrans = 5.501190 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:57:46 Magnet Current, Imag = 550.1390 A Vtrans = 5.501390 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:57:48 Magnet Current, Imag = 550.1300 A Vtrans = 5.501300 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:57:50 Magnet Current, Imag = 550.1290 A Vtrans = 5.501290 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:57:50 Magnet Current Measurement: Imag = 550.1292 +- 0.0071 A 15:57:50 Magnet current ramping to 500.0000 A... 15:58:13 Magnet Current, Imag = 500.1330 A Vtrans = 5.001330 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:58:15 Magnet Current, Imag = 500.1260 A Vtrans = 5.001260 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:58:16 Magnet Current, Imag = 500.1230 A Vtrans = 5.001230 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:58:18 Magnet Current, Imag = 500.1200 A Vtrans = 5.001200 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:58:18 Magnet Current Measurement: Imag = 500.1255 +- 0.0048 A 15:58:18 Magnetic Field Measurement Measuring the magnet strength... 15:58:18 Integrated Voltage Measurement... 15:58:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015959293 Vs 15:58:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015951717 Vs 15:58:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015950119 Vs 15:59:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015968411 Vs 15:59:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015951803 Vs 15:59:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015967677 Vs 15:59:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015964420 Vs 15:59:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015962329 Vs 15:59:46 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015959471 +- 0.000002788 Vs 15:59:46 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.015959471 +- 0.000002788 Vs BL = 1.59594710 +- 0.00027876 Tm 15:59:49 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.59595 0.00028 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.59595 0.00028 1.59595 0.00000 15:59:49 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.59595 0.00028 SL = 1.5959471 +- 0.0002788 Tm^2/m^n 15:59:49 Magnet Strength Measurement Harmonic Number = 1 SL = 1.5959471 +- 0.0002788 Tm^2/m^n 15:59:51 Magnet Current, Imag = 500.1240 A Vtrans = 5.001240 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:59:52 Magnet Current, Imag = 500.1250 A Vtrans = 5.001250 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:59:54 Magnet Current, Imag = 500.1120 A Vtrans = 5.001120 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:59:56 Magnet Current, Imag = 500.1250 A Vtrans = 5.001250 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:59:56 Magnet Current Measurement: Imag = 500.1215 +- 0.0055 A 15:59:56 Magnet current ramping to 450.0000 A... 16:00:19 Magnet Current, Imag = 450.0670 A Vtrans = 4.500670 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:00:20 Magnet Current, Imag = 450.0530 A Vtrans = 4.500530 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:00:22 Magnet Current, Imag = 450.0690 A Vtrans = 4.500690 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:00:24 Magnet Current, Imag = 450.0630 A Vtrans = 4.500630 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:00:24 Magnet Current Measurement: Imag = 450.0630 +- 0.0062 A 16:00:24 Magnetic Field Measurement Measuring the magnet strength... 16:00:24 Integrated Voltage Measurement... 16:00:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014366955 Vs 16:00:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014375525 Vs 16:00:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014366917 Vs 16:01:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014373939 Vs 16:01:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014362586 Vs 16:01:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014378122 Vs 16:01:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014375232 Vs 16:01:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014386289 Vs 16:01:52 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014373196 +- 0.000004381 Vs 16:01:52 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.014373196 +- 0.000004381 Vs BL = 1.43731956 +- 0.00043813 Tm 16:01:55 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.43732 0.00044 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.43732 0.00044 1.43732 0.00000 16:01:55 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.43732 0.00044 SL = 1.4373196 +- 0.0004381 Tm^2/m^n 16:01:55 Magnet Strength Measurement Harmonic Number = 1 SL = 1.4373196 +- 0.0004381 Tm^2/m^n 16:01:57 Magnet Current, Imag = 450.0710 A Vtrans = 4.500710 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:01:58 Magnet Current, Imag = 450.0820 A Vtrans = 4.500820 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:02:00 Magnet Current, Imag = 450.0780 A Vtrans = 4.500780 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:02:01 Magnet Current, Imag = 450.0740 A Vtrans = 4.500740 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:02:01 Magnet Current Measurement: Imag = 450.0762 +- 0.0041 A 16:02:02 Magnet current ramping to 400.0000 A... 16:02:25 Magnet Current, Imag = 400.0640 A Vtrans = 4.000640 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:02:26 Magnet Current, Imag = 400.0550 A Vtrans = 4.000550 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:02:28 Magnet Current, Imag = 400.0500 A Vtrans = 4.000500 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:02:30 Magnet Current, Imag = 400.0580 A Vtrans = 4.000580 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:02:30 Magnet Current Measurement: Imag = 400.0567 +- 0.0051 A 16:02:30 Magnetic Field Measurement Measuring the magnet strength... 16:02:30 Integrated Voltage Measurement... 16:02:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012764613 Vs 16:02:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012794374 Vs 16:03:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012780949 Vs 16:03:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012790624 Vs 16:03:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012790654 Vs 16:03:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012787987 Vs 16:03:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012783554 Vs 16:03:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012791731 Vs 16:03:58 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012785561 +- 0.000003719 Vs 16:03:58 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.012785561 +- 0.000003719 Vs BL = 1.27855607 +- 0.00037193 Tm 16:04:01 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.27856 0.00037 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.27856 0.00037 1.27856 0.00000 16:04:01 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.27856 0.00037 SL = 1.2785561 +- 0.0003719 Tm^2/m^n 16:04:01 Magnet Strength Measurement Harmonic Number = 1 SL = 1.2785561 +- 0.0003719 Tm^2/m^n 16:04:03 Magnet Current, Imag = 400.0130 A Vtrans = 4.000130 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:04:04 Magnet Current, Imag = 400.0200 A Vtrans = 4.000200 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:04:06 Magnet Current, Imag = 400.0150 A Vtrans = 4.000150 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:04:07 Magnet Current, Imag = 400.0200 A Vtrans = 4.000200 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:04:07 Magnet Current Measurement: Imag = 400.0170 +- 0.0031 A 16:04:38 Magnet current ramping to 0.0000 A...