SLAC Magnetic Measurements Date: 07-12-2001 Time: 15:20:40 Project: spear3 Magnet Type: gdipole Magnet Name: 145d-012 Serial Number: Run Number: 6 Measurement Device: stretched wire Operator: jy Comment: BL vs. I, mains Standardization: 1 cycles from 0.0 A to 770.0 A to 0.0 A Test Currents (A): 50.0 100.0 150.0 200.0 250.0 300.0 350.0 400.0 450.0 500.0 525.0 550.0 575.0 600.0 625.0 650.0 675.0 700.0 650.0 600.0 550.0 500.0 450.0 400.0 15:20:48 Initial Zero Current Measurement, Imag_zero = 0.0000 A 15:20:48 Magnet current ramping to 15.0000 A... 15:21:19 Magnet current ramping to 770.0000 A... 15:25:33 Magnet current ramping to 0.0000 A... 15:30:21 Magnet current ramping to 50.0000 A... 15:30:45 Magnet Current, Imag = 50.8192 A Vtrans = 0.508192 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:30:46 Magnet Current, Imag = 49.8582 A Vtrans = 0.498582 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:30:48 Magnet Current, Imag = 49.7717 A Vtrans = 0.497717 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:30:49 Magnet Current, Imag = 50.0333 A Vtrans = 0.500333 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:30:49 Magnet Current Measurement: Imag = 50.1206 +- 0.4142 A 15:30:49 Magnetic Field Measurement Measuring the magnet strength... 15:30:49 Integrated Voltage Measurement... 15:31:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001435563 Vs 15:31:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001784987 Vs 15:31:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001422789 Vs 15:31:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001782929 Vs 15:31:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001427075 Vs 15:31:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001785726 Vs 15:32:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001425041 Vs 15:32:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001780867 Vs 15:32:18 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001605622 +- 0.000003042 Vs 15:32:18 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.001605622 +- 0.000003042 Vs BL = 0.16056221 +- 0.00030417 Tm 15:32:21 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.16056 0.00030 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.16056 0.00030 0.16056 0.00000 15:32:21 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.16056 0.00030 SL = 0.1605622 +- 0.0003042 Tm^2/m^n 15:32:21 Magnet Strength Measurement Harmonic Number = 1 SL = 0.1605622 +- 0.0003042 Tm^2/m^n 15:32:23 Magnet Current, Imag = 49.9470 A Vtrans = 0.499470 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:32:24 Magnet Current, Imag = 49.9538 A Vtrans = 0.499538 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:32:26 Magnet Current, Imag = 49.9472 A Vtrans = 0.499472 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:32:27 Magnet Current, Imag = 49.9556 A Vtrans = 0.499556 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:32:27 Magnet Current Measurement: Imag = 49.9509 +- 0.0039 A 15:32:27 Magnet current ramping to 100.0000 A... 15:32:50 Magnet Current, Imag = 99.9564 A Vtrans = 0.999564 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:32:52 Magnet Current, Imag = 99.9768 A Vtrans = 0.999768 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:32:53 Magnet Current, Imag = 100.0037 A Vtrans = 1.000037 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:32:55 Magnet Current, Imag = 99.9452 A Vtrans = 0.999452 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:32:55 Magnet Current Measurement: Imag = 99.9705 +- 0.0223 A 15:32:55 Magnetic Field Measurement Measuring the magnet strength... 15:32:55 Integrated Voltage Measurement... 15:33:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003009413 Vs 15:33:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003358098 Vs 15:33:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002989913 Vs 15:33:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003345349 Vs 15:33:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002974253 Vs 15:34:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003368703 Vs 15:34:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002977567 Vs 15:34:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003335841 Vs 15:34:23 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003169892 +- 0.000009666 Vs 15:34:23 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.003169892 +- 0.000009666 Vs BL = 0.31698922 +- 0.00096663 Tm 15:34:26 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.31699 0.00097 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.31699 0.00097 0.31699 0.00000 15:34:26 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.31699 0.00097 SL = 0.3169892 +- 0.0009666 Tm^2/m^n 15:34:27 Magnet Strength Measurement Harmonic Number = 1 SL = 0.3169892 +- 0.0009666 Tm^2/m^n 15:34:28 Magnet Current, Imag = 100.0327 A Vtrans = 1.000327 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:34:30 Magnet Current, Imag = 100.0134 A Vtrans = 1.000134 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:34:31 Magnet Current, Imag = 99.9963 A Vtrans = 0.999963 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:34:33 Magnet Current, Imag = 99.9979 A Vtrans = 0.999979 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:34:33 Magnet Current Measurement: Imag = 100.0101 +- 0.0147 A 15:34:33 Magnet current ramping to 150.0000 A... 15:34:56 Magnet Current, Imag = 149.9837 A Vtrans = 1.499837 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:34:57 Magnet Current, Imag = 150.0490 A Vtrans = 1.500490 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:34:58 Magnet Current, Imag = 149.9955 A Vtrans = 1.499955 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:35:00 Magnet Current, Imag = 149.9976 A Vtrans = 1.499976 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:35:00 Magnet Current Measurement: Imag = 150.0065 +- 0.0251 A 15:35:00 Magnetic Field Measurement Measuring the magnet strength... 15:35:00 Integrated Voltage Measurement... 15:35:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004561233 Vs 15:35:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004952029 Vs 15:35:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004591789 Vs 15:35:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004958465 Vs 15:35:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004602604 Vs 15:36:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004944885 Vs 15:36:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004583412 Vs 15:36:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004978381 Vs 15:36:29 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004771600 +- 0.000009049 Vs 15:36:29 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.004771600 +- 0.000009049 Vs BL = 0.47715997 +- 0.00090491 Tm 15:36:32 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.47716 0.00090 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.47716 0.00090 0.47716 0.00000 15:36:32 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.47716 0.00090 SL = 0.4771600 +- 0.0009049 Tm^2/m^n 15:36:32 Magnet Strength Measurement Harmonic Number = 1 SL = 0.4771600 +- 0.0009049 Tm^2/m^n 15:36:33 Magnet Current, Imag = 150.0209 A Vtrans = 1.500209 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:36:35 Magnet Current, Imag = 150.0019 A Vtrans = 1.500019 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:36:36 Magnet Current, Imag = 150.0137 A Vtrans = 1.500137 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:36:38 Magnet Current, Imag = 150.0062 A Vtrans = 1.500062 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:36:38 Magnet Current Measurement: Imag = 150.0107 +- 0.0073 A 15:36:38 Magnet current ramping to 200.0000 A... 15:37:02 Magnet Current, Imag = 200.0147 A Vtrans = 2.000147 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:37:03 Magnet Current, Imag = 199.9978 A Vtrans = 1.999978 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:37:05 Magnet Current, Imag = 200.0004 A Vtrans = 2.000004 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:37:06 Magnet Current, Imag = 200.0022 A Vtrans = 2.000022 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:37:06 Magnet Current Measurement: Imag = 200.0038 +- 0.0065 A 15:37:06 Magnetic Field Measurement Measuring the magnet strength... 15:37:06 Integrated Voltage Measurement... 15:37:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006176055 Vs 15:37:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006542279 Vs 15:37:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006185432 Vs 15:37:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006559391 Vs 15:38:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006165777 Vs 15:38:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006520227 Vs 15:38:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006190841 Vs 15:38:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006480862 Vs 15:38:35 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006352608 +- 0.000014215 Vs 15:38:35 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.006352608 +- 0.000014215 Vs BL = 0.63526080 +- 0.00142148 Tm 15:38:38 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.63526 0.00142 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.63526 0.00142 0.63526 0.00000 15:38:38 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.63526 0.00142 SL = 0.6352608 +- 0.0014215 Tm^2/m^n 15:38:38 Magnet Strength Measurement Harmonic Number = 1 SL = 0.6352608 +- 0.0014215 Tm^2/m^n 15:38:39 Magnet Current, Imag = 199.8043 A Vtrans = 1.998043 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:38:41 Magnet Current, Imag = 199.8768 A Vtrans = 1.998768 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:38:42 Magnet Current, Imag = 200.0761 A Vtrans = 2.000761 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:38:44 Magnet Current, Imag = 200.1378 A Vtrans = 2.001378 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:38:44 Magnet Current Measurement: Imag = 199.9737 +- 0.1374 A 15:38:44 Magnet current ramping to 250.0000 A... 15:39:07 Magnet Current, Imag = 250.0198 A Vtrans = 2.500198 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:39:08 Magnet Current, Imag = 250.0110 A Vtrans = 2.500110 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:39:10 Magnet Current, Imag = 250.0334 A Vtrans = 2.500334 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:39:11 Magnet Current, Imag = 250.0538 A Vtrans = 2.500538 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:39:11 Magnet Current Measurement: Imag = 250.0295 +- 0.0161 A 15:39:11 Magnetic Field Measurement Measuring the magnet strength... 15:39:12 Integrated Voltage Measurement... 15:39:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007763532 Vs 15:39:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008147019 Vs 15:39:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007715734 Vs 15:39:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008129556 Vs 15:40:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007802119 Vs 15:40:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008126521 Vs 15:40:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007739997 Vs 15:40:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008115322 Vs 15:40:40 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007942475 +- 0.000017704 Vs 15:40:40 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.007942475 +- 0.000017704 Vs BL = 0.79424750 +- 0.00177043 Tm 15:40:43 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.79425 0.00177 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.79425 0.00177 0.79425 0.00000 15:40:43 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.79425 0.00177 SL = 0.7942475 +- 0.0017704 Tm^2/m^n 15:40:43 Magnet Strength Measurement Harmonic Number = 1 SL = 0.7942475 +- 0.0017704 Tm^2/m^n 15:40:45 Magnet Current, Imag = 250.0048 A Vtrans = 2.500048 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:40:46 Magnet Current, Imag = 250.0839 A Vtrans = 2.500839 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:40:48 Magnet Current, Imag = 250.0606 A Vtrans = 2.500606 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:40:49 Magnet Current, Imag = 249.9873 A Vtrans = 2.499873 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:40:49 Magnet Current Measurement: Imag = 250.0342 +- 0.0395 A 15:40:50 Magnet current ramping to 300.0000 A... 15:41:12 Magnet Current, Imag = 300.0403 A Vtrans = 3.000403 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:41:14 Magnet Current, Imag = 300.0781 A Vtrans = 3.000781 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:41:15 Magnet Current, Imag = 300.0086 A Vtrans = 3.000086 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:41:17 Magnet Current, Imag = 300.0638 A Vtrans = 3.000638 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:41:17 Magnet Current Measurement: Imag = 300.0477 +- 0.0263 A 15:41:17 Magnetic Field Measurement Measuring the magnet strength... 15:41:17 Integrated Voltage Measurement... 15:41:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009374201 Vs 15:41:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009739766 Vs 15:41:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009385795 Vs 15:42:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009709971 Vs 15:42:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009535720 Vs 15:42:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009732835 Vs 15:42:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009367831 Vs 15:42:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009680612 Vs 15:42:46 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009565842 +- 0.000041281 Vs 15:42:46 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.009565842 +- 0.000041281 Vs BL = 0.95658415 +- 0.00412814 Tm 15:42:49 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.95658 0.00413 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.95658 0.00413 0.95658 0.00000 15:42:49 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.95658 0.00413 SL = 0.9565841 +- 0.0041281 Tm^2/m^n 15:42:49 Magnet Strength Measurement Harmonic Number = 1 SL = 0.9565841 +- 0.0041281 Tm^2/m^n 15:42:50 Magnet Current, Imag = 299.5756 A Vtrans = 2.995756 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:42:52 Magnet Current, Imag = 300.3399 A Vtrans = 3.003399 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:42:53 Magnet Current, Imag = 300.7550 A Vtrans = 3.007550 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:42:55 Magnet Current, Imag = 299.0991 A Vtrans = 2.990991 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:42:55 Magnet Current Measurement: Imag = 299.9424 +- 0.6450 A 15:42:55 Magnet current ramping to 350.0000 A... 15:43:19 Magnet Current, Imag = 350.0880 A Vtrans = 3.500880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:43:21 Magnet Current, Imag = 350.0720 A Vtrans = 3.500720 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:43:23 Magnet Current, Imag = 350.0680 A Vtrans = 3.500680 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:43:24 Magnet Current, Imag = 350.0660 A Vtrans = 3.500660 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:43:25 Magnet Current Measurement: Imag = 350.0735 +- 0.0086 A 15:43:25 Magnetic Field Measurement Measuring the magnet strength... 15:43:25 Integrated Voltage Measurement... 15:43:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010964355 Vs 15:43:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011243810 Vs 15:43:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010899123 Vs 15:44:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011471146 Vs 15:44:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010980978 Vs 15:44:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011334479 Vs 15:44:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010969934 Vs 15:44:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011320697 Vs 15:44:53 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011148065 +- 0.000029196 Vs 15:44:53 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.011148065 +- 0.000029196 Vs BL = 1.11480654 +- 0.00291957 Tm 15:44:56 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.11481 0.00292 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.11481 0.00292 1.11481 0.00000 15:44:56 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.11481 0.00292 SL = 1.1148065 +- 0.0029196 Tm^2/m^n 15:44:56 Magnet Strength Measurement Harmonic Number = 1 SL = 1.1148065 +- 0.0029196 Tm^2/m^n 15:44:58 Magnet Current, Imag = 350.0890 A Vtrans = 3.500890 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:45:00 Magnet Current, Imag = 350.0870 A Vtrans = 3.500870 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:45:02 Magnet Current, Imag = 350.0970 A Vtrans = 3.500970 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:45:04 Magnet Current, Imag = 350.1030 A Vtrans = 3.501030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:45:04 Magnet Current Measurement: Imag = 350.0940 +- 0.0064 A 15:45:05 Magnet current ramping to 400.0000 A... 15:45:28 Magnet Current, Imag = 400.0580 A Vtrans = 4.000580 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:45:30 Magnet Current, Imag = 400.0890 A Vtrans = 4.000890 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:45:31 Magnet Current, Imag = 400.0810 A Vtrans = 4.000810 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:45:33 Magnet Current, Imag = 400.0780 A Vtrans = 4.000780 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:45:33 Magnet Current Measurement: Imag = 400.0765 +- 0.0114 A 15:45:33 Magnetic Field Measurement Measuring the magnet strength... 15:45:33 Integrated Voltage Measurement... 15:45:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012543722 Vs 15:45:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012910603 Vs 15:46:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012564595 Vs 15:46:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012919357 Vs 15:46:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012559674 Vs 15:46:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012912112 Vs 15:46:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012546219 Vs 15:47:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012912454 Vs 15:47:01 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012733592 +- 0.000005810 Vs 15:47:02 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.012733592 +- 0.000005810 Vs BL = 1.27335921 +- 0.00058101 Tm 15:47:05 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.27336 0.00058 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.27336 0.00058 1.27336 0.00000 15:47:05 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.27336 0.00058 SL = 1.2733592 +- 0.0005810 Tm^2/m^n 15:47:05 Magnet Strength Measurement Harmonic Number = 1 SL = 1.2733592 +- 0.0005810 Tm^2/m^n 15:47:06 Magnet Current, Imag = 400.0790 A Vtrans = 4.000790 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:08 Magnet Current, Imag = 400.0800 A Vtrans = 4.000800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:10 Magnet Current, Imag = 400.0800 A Vtrans = 4.000800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:11 Magnet Current, Imag = 400.0980 A Vtrans = 4.000980 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:11 Magnet Current Measurement: Imag = 400.0842 +- 0.0079 A 15:47:12 Magnet current ramping to 450.0000 A... 15:47:35 Magnet Current, Imag = 450.0870 A Vtrans = 4.500870 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:36 Magnet Current, Imag = 450.0920 A Vtrans = 4.500920 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:38 Magnet Current, Imag = 450.0940 A Vtrans = 4.500940 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:39 Magnet Current, Imag = 450.1050 A Vtrans = 4.501050 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:39 Magnet Current Measurement: Imag = 450.0945 +- 0.0066 A 15:47:40 Magnetic Field Measurement Measuring the magnet strength... 15:47:40 Integrated Voltage Measurement... 15:47:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014136803 Vs 15:48:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014508485 Vs 15:48:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014140639 Vs 15:48:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014491689 Vs 15:48:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014133747 Vs 15:48:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014487365 Vs 15:48:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014140171 Vs 15:49:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014502723 Vs 15:49:08 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014317703 +- 0.000004793 Vs 15:49:09 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.014317703 +- 0.000004793 Vs BL = 1.43177028 +- 0.00047926 Tm 15:49:12 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.43177 0.00048 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.43177 0.00048 1.43177 0.00000 15:49:12 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.43177 0.00048 SL = 1.4317703 +- 0.0004793 Tm^2/m^n 15:49:12 Magnet Strength Measurement Harmonic Number = 1 SL = 1.4317703 +- 0.0004793 Tm^2/m^n 15:49:13 Magnet Current, Imag = 450.1150 A Vtrans = 4.501150 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:49:15 Magnet Current, Imag = 450.1050 A Vtrans = 4.501050 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:49:17 Magnet Current, Imag = 450.1140 A Vtrans = 4.501140 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:49:18 Magnet Current, Imag = 450.1110 A Vtrans = 4.501110 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:49:18 Magnet Current Measurement: Imag = 450.1112 +- 0.0039 A 15:49:18 Magnet current ramping to 500.0000 A... 15:49:41 Magnet Current, Imag = 500.1500 A Vtrans = 5.001500 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:49:43 Magnet Current, Imag = 500.1600 A Vtrans = 5.001600 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:49:45 Magnet Current, Imag = 500.1580 A Vtrans = 5.001580 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:49:46 Magnet Current, Imag = 500.1460 A Vtrans = 5.001460 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:49:46 Magnet Current Measurement: Imag = 500.1535 +- 0.0057 A 15:49:46 Magnetic Field Measurement Measuring the magnet strength... 15:49:47 Integrated Voltage Measurement... 15:50:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015718214 Vs 15:50:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016089545 Vs 15:50:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015720186 Vs 15:50:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016081099 Vs 15:50:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015718544 Vs 15:50:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016080405 Vs 15:51:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015721198 Vs 15:51:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016086888 Vs 15:51:15 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015902010 +- 0.000001995 Vs 15:51:15 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.015902010 +- 0.000001995 Vs BL = 1.59020100 +- 0.00019954 Tm 15:51:18 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.59020 0.00020 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.59020 0.00020 1.59020 0.00000 15:51:19 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.59020 0.00020 SL = 1.5902010 +- 0.0001995 Tm^2/m^n 15:51:19 Magnet Strength Measurement Harmonic Number = 1 SL = 1.5902010 +- 0.0001995 Tm^2/m^n 15:51:20 Magnet Current, Imag = 500.1340 A Vtrans = 5.001340 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:51:22 Magnet Current, Imag = 500.1490 A Vtrans = 5.001490 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:51:23 Magnet Current, Imag = 500.1540 A Vtrans = 5.001540 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:51:25 Magnet Current, Imag = 500.1510 A Vtrans = 5.001510 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:51:25 Magnet Current Measurement: Imag = 500.1470 +- 0.0077 A 15:51:25 Magnet current ramping to 525.0000 A... 15:51:41 Magnet Current, Imag = 525.0970 A Vtrans = 5.250970 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:51:42 Magnet Current, Imag = 525.1280 A Vtrans = 5.251280 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:51:44 Magnet Current, Imag = 525.1540 A Vtrans = 5.251540 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:51:46 Magnet Current, Imag = 525.1570 A Vtrans = 5.251570 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:51:46 Magnet Current Measurement: Imag = 525.1340 +- 0.0242 A 15:51:46 Magnetic Field Measurement Measuring the magnet strength... 15:51:46 Integrated Voltage Measurement... 15:51:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016517023 Vs 15:52:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016872408 Vs 15:52:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016513195 Vs 15:52:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016873655 Vs 15:52:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016509731 Vs 15:52:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016866085 Vs 15:53:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016519309 Vs 15:53:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016867480 Vs 15:53:15 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016692361 +- 0.000002626 Vs 15:53:15 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.016692361 +- 0.000002626 Vs BL = 1.66923607 +- 0.00026257 Tm 15:53:18 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.66924 0.00026 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.66924 0.00026 1.66924 0.00000 15:53:18 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.66924 0.00026 SL = 1.6692361 +- 0.0002626 Tm^2/m^n 15:53:18 Magnet Strength Measurement Harmonic Number = 1 SL = 1.6692361 +- 0.0002626 Tm^2/m^n 15:53:19 Magnet Current, Imag = 525.1600 A Vtrans = 5.251600 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:53:21 Magnet Current, Imag = 525.1590 A Vtrans = 5.251590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:53:23 Magnet Current, Imag = 525.1540 A Vtrans = 5.251540 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:53:24 Magnet Current, Imag = 525.1620 A Vtrans = 5.251620 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:53:24 Magnet Current Measurement: Imag = 525.1588 +- 0.0029 A 15:53:24 Magnet current ramping to 550.0000 A... 15:53:40 Magnet Current, Imag = 550.0930 A Vtrans = 5.500930 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:53:42 Magnet Current, Imag = 550.1130 A Vtrans = 5.501130 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:53:43 Magnet Current, Imag = 550.1230 A Vtrans = 5.501230 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:53:45 Magnet Current, Imag = 550.1290 A Vtrans = 5.501290 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:53:45 Magnet Current Measurement: Imag = 550.1145 +- 0.0137 A 15:53:45 Magnetic Field Measurement Measuring the magnet strength... 15:53:45 Integrated Voltage Measurement... 15:53:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017277907 Vs 15:54:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017652442 Vs 15:54:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017288002 Vs 15:54:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017653151 Vs 15:54:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017292704 Vs 15:54:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017647676 Vs 15:55:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017282113 Vs 15:55:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017647953 Vs 15:55:14 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017467744 +- 0.000002644 Vs 15:55:14 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.017467744 +- 0.000002644 Vs BL = 1.74677436 +- 0.00026436 Tm 15:55:17 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.74677 0.00026 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.74677 0.00026 1.74677 0.00000 15:55:17 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.74677 0.00026 SL = 1.7467744 +- 0.0002644 Tm^2/m^n 15:55:17 Magnet Strength Measurement Harmonic Number = 1 SL = 1.7467744 +- 0.0002644 Tm^2/m^n 15:55:19 Magnet Current, Imag = 550.1440 A Vtrans = 5.501440 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:55:21 Magnet Current, Imag = 550.1290 A Vtrans = 5.501290 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:55:22 Magnet Current, Imag = 550.1360 A Vtrans = 5.501360 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:55:24 Magnet Current, Imag = 550.1310 A Vtrans = 5.501310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:55:24 Magnet Current Measurement: Imag = 550.1350 +- 0.0058 A 15:55:24 Magnet current ramping to 575.0000 A... 15:55:40 Magnet Current, Imag = 575.1230 A Vtrans = 5.751230 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:55:41 Magnet Current, Imag = 575.1270 A Vtrans = 5.751270 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:55:43 Magnet Current, Imag = 575.1350 A Vtrans = 5.751350 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:55:44 Magnet Current, Imag = 575.1460 A Vtrans = 5.751460 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:55:45 Magnet Current Measurement: Imag = 575.1327 +- 0.0088 A 15:55:45 Magnetic Field Measurement Measuring the magnet strength... 15:55:45 Integrated Voltage Measurement... 15:55:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018048038 Vs 15:56:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018421931 Vs 15:56:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018064773 Vs 15:56:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018429351 Vs 15:56:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018042953 Vs 15:56:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018418602 Vs 15:57:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018056899 Vs 15:57:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018431619 Vs 15:57:14 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018239271 +- 0.000006635 Vs 15:57:14 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.018239271 +- 0.000006635 Vs BL = 1.82392708 +- 0.00066351 Tm 15:57:17 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.82393 0.00066 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.82393 0.00066 1.82393 0.00000 15:57:17 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.82393 0.00066 SL = 1.8239271 +- 0.0006635 Tm^2/m^n 15:57:17 Magnet Strength Measurement Harmonic Number = 1 SL = 1.8239271 +- 0.0006635 Tm^2/m^n 15:57:19 Magnet Current, Imag = 575.1180 A Vtrans = 5.751180 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:57:20 Magnet Current, Imag = 575.1260 A Vtrans = 5.751260 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:57:22 Magnet Current, Imag = 575.1580 A Vtrans = 5.751580 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:57:23 Magnet Current, Imag = 575.1530 A Vtrans = 5.751530 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:57:23 Magnet Current Measurement: Imag = 575.1387 +- 0.0171 A 15:57:24 Magnet current ramping to 600.0000 A... 15:57:39 Magnet Current, Imag = 600.1900 A Vtrans = 6.001900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:57:41 Magnet Current, Imag = 600.1400 A Vtrans = 6.001400 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:57:43 Magnet Current, Imag = 600.2180 A Vtrans = 6.002180 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:57:44 Magnet Current, Imag = 600.1580 A Vtrans = 6.001580 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:57:44 Magnet Current Measurement: Imag = 600.1765 +- 0.0299 A 15:57:44 Magnetic Field Measurement Measuring the magnet strength... 15:57:44 Integrated Voltage Measurement... 15:57:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018816513 Vs 15:58:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019189467 Vs 15:58:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018809900 Vs 15:58:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019184147 Vs 15:58:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018824338 Vs 15:58:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019187449 Vs 15:59:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018808755 Vs 15:59:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019178124 Vs 15:59:13 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018999837 +- 0.000004885 Vs 15:59:13 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.018999837 +- 0.000004885 Vs BL = 1.89998367 +- 0.00048853 Tm 15:59:16 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.89998 0.00049 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.89998 0.00049 1.89998 0.00000 15:59:16 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.89998 0.00049 SL = 1.8999837 +- 0.0004885 Tm^2/m^n 15:59:16 Magnet Strength Measurement Harmonic Number = 1 SL = 1.8999837 +- 0.0004885 Tm^2/m^n 15:59:18 Magnet Current, Imag = 600.1640 A Vtrans = 6.001640 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:59:20 Magnet Current, Imag = 600.1550 A Vtrans = 6.001550 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:59:21 Magnet Current, Imag = 600.1480 A Vtrans = 6.001480 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:59:23 Magnet Current, Imag = 600.1970 A Vtrans = 6.001970 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:59:23 Magnet Current Measurement: Imag = 600.1660 +- 0.0188 A 15:59:23 Magnet current ramping to 625.0000 A... 15:59:39 Magnet Current, Imag = 625.2240 A Vtrans = 6.252240 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:59:40 Magnet Current, Imag = 625.2170 A Vtrans = 6.252170 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:59:42 Magnet Current, Imag = 625.2030 A Vtrans = 6.252030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:59:43 Magnet Current, Imag = 625.2020 A Vtrans = 6.252020 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:59:43 Magnet Current Measurement: Imag = 625.2115 +- 0.0093 A 15:59:44 Magnetic Field Measurement Measuring the magnet strength... 15:59:44 Integrated Voltage Measurement... 15:59:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019561401 Vs 16:00:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019919001 Vs 16:00:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019555365 Vs 16:00:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019925157 Vs 16:00:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019553318 Vs 16:00:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019927382 Vs 16:01:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019564045 Vs 16:01:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019930781 Vs 16:01:13 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019742056 +- 0.000003093 Vs 16:01:13 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.019742056 +- 0.000003093 Vs BL = 1.97420562 +- 0.00030932 Tm 16:01:16 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.97421 0.00031 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.97421 0.00031 1.97421 0.00000 16:01:16 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.97421 0.00031 SL = 1.9742056 +- 0.0003093 Tm^2/m^n 16:01:16 Magnet Strength Measurement Harmonic Number = 1 SL = 1.9742056 +- 0.0003093 Tm^2/m^n 16:01:18 Magnet Current, Imag = 625.1910 A Vtrans = 6.251910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:01:19 Magnet Current, Imag = 625.1940 A Vtrans = 6.251940 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:01:21 Magnet Current, Imag = 625.1840 A Vtrans = 6.251840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:01:22 Magnet Current, Imag = 625.1880 A Vtrans = 6.251880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:01:22 Magnet Current Measurement: Imag = 625.1892 +- 0.0037 A 16:01:23 Magnet current ramping to 650.0000 A... 16:01:38 Magnet Current, Imag = 650.2450 A Vtrans = 6.502450 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:01:40 Magnet Current, Imag = 650.2430 A Vtrans = 6.502430 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:01:41 Magnet Current, Imag = 650.2300 A Vtrans = 6.502300 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:01:43 Magnet Current, Imag = 650.2220 A Vtrans = 6.502220 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:01:43 Magnet Current Measurement: Imag = 650.2350 +- 0.0095 A 16:01:43 Magnetic Field Measurement Measuring the magnet strength... 16:01:43 Integrated Voltage Measurement... 16:01:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020263481 Vs 16:02:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020615059 Vs 16:02:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020267484 Vs 16:02:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020626639 Vs 16:02:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020266913 Vs 16:02:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020625528 Vs 16:03:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020266653 Vs 16:03:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020623707 Vs 16:03:12 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020444433 +- 0.000003054 Vs 16:03:12 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.020444433 +- 0.000003054 Vs BL = 2.04444331 +- 0.00030543 Tm 16:03:15 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.04444 0.00031 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.04444 0.00031 2.04444 0.00000 16:03:15 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.04444 0.00031 SL = 2.0444433 +- 0.0003054 Tm^2/m^n 16:03:15 Magnet Strength Measurement Harmonic Number = 1 SL = 2.0444433 +- 0.0003054 Tm^2/m^n 16:03:17 Magnet Current, Imag = 650.2080 A Vtrans = 6.502080 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:03:19 Magnet Current, Imag = 650.2040 A Vtrans = 6.502040 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:03:20 Magnet Current, Imag = 650.2060 A Vtrans = 6.502060 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:03:22 Magnet Current, Imag = 650.2030 A Vtrans = 6.502030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:03:22 Magnet Current Measurement: Imag = 650.2052 +- 0.0019 A 16:03:22 Magnet current ramping to 675.0000 A... 16:03:38 Magnet Current, Imag = 675.2190 A Vtrans = 6.752190 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:03:39 Magnet Current, Imag = 675.2280 A Vtrans = 6.752280 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:03:41 Magnet Current, Imag = 675.2200 A Vtrans = 6.752200 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:03:42 Magnet Current, Imag = 675.2310 A Vtrans = 6.752310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:03:42 Magnet Current Measurement: Imag = 675.2245 +- 0.0051 A 16:03:43 Magnetic Field Measurement Measuring the magnet strength... 16:03:43 Integrated Voltage Measurement... 16:03:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020924102 Vs 16:04:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021286006 Vs 16:04:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020930835 Vs 16:04:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021283062 Vs 16:04:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020918042 Vs 16:04:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021290263 Vs 16:05:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020925689 Vs 16:05:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021282187 Vs 16:05:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021105023 +- 0.000001188 Vs 16:05:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.021105023 +- 0.000001188 Vs BL = 2.11050233 +- 0.00011877 Tm 16:05:14 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.11050 0.00012 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.11050 0.00012 2.11050 0.00000 16:05:14 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.11050 0.00012 SL = 2.1105023 +- 0.0001188 Tm^2/m^n 16:05:15 Magnet Strength Measurement Harmonic Number = 1 SL = 2.1105023 +- 0.0001188 Tm^2/m^n 16:05:16 Magnet Current, Imag = 675.2700 A Vtrans = 6.752700 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:05:18 Magnet Current, Imag = 675.2490 A Vtrans = 6.752490 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:05:19 Magnet Current, Imag = 675.2280 A Vtrans = 6.752280 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:05:21 Magnet Current, Imag = 675.2240 A Vtrans = 6.752240 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:05:21 Magnet Current Measurement: Imag = 675.2427 +- 0.0184 A 16:05:21 Magnet current ramping to 700.0000 A... 16:05:37 Magnet Current, Imag = 700.2240 A Vtrans = 7.002240 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:05:38 Magnet Current, Imag = 700.2500 A Vtrans = 7.002500 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:05:40 Magnet Current, Imag = 700.2550 A Vtrans = 7.002550 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:05:42 Magnet Current, Imag = 700.2180 A Vtrans = 7.002180 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:05:42 Magnet Current Measurement: Imag = 700.2367 +- 0.0160 A 16:05:42 Magnetic Field Measurement Measuring the magnet strength... 16:05:42 Integrated Voltage Measurement... 16:05:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021540242 Vs 16:06:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021894847 Vs 16:06:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021534338 Vs 16:06:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021905476 Vs 16:06:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021540173 Vs 16:06:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021909795 Vs 16:07:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021549295 Vs 16:07:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021901665 Vs 16:07:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021721979 +- 0.000003363 Vs 16:07:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.021721979 +- 0.000003363 Vs BL = 2.17219789 +- 0.00033632 Tm 16:07:14 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.17220 0.00034 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.17220 0.00034 2.17220 0.00000 16:07:14 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.17220 0.00034 SL = 2.1721979 +- 0.0003363 Tm^2/m^n 16:07:14 Magnet Strength Measurement Harmonic Number = 1 SL = 2.1721979 +- 0.0003363 Tm^2/m^n 16:07:16 Magnet Current, Imag = 700.2270 A Vtrans = 7.002270 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:07:17 Magnet Current, Imag = 700.2470 A Vtrans = 7.002470 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:07:19 Magnet Current, Imag = 700.2410 A Vtrans = 7.002410 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:07:20 Magnet Current, Imag = 700.2570 A Vtrans = 7.002570 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:07:20 Magnet Current Measurement: Imag = 700.2430 +- 0.0109 A 16:07:21 Magnet current ramping to 650.0000 A... 16:07:44 Magnet Current, Imag = 650.2110 A Vtrans = 6.502110 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:07:45 Magnet Current, Imag = 650.2130 A Vtrans = 6.502130 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:07:47 Magnet Current, Imag = 650.2220 A Vtrans = 6.502220 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:07:48 Magnet Current, Imag = 650.2090 A Vtrans = 6.502090 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:07:48 Magnet Current Measurement: Imag = 650.2138 +- 0.0050 A 16:07:49 Magnetic Field Measurement Measuring the magnet strength... 16:07:49 Integrated Voltage Measurement... 16:08:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020348147 Vs 16:08:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020703177 Vs 16:08:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020350822 Vs 16:08:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020693468 Vs 16:08:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020347281 Vs 16:08:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020701618 Vs 16:09:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020345735 Vs 16:09:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020705981 Vs 16:09:17 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020524528 +- 0.000001478 Vs 16:09:17 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.020524528 +- 0.000001478 Vs BL = 2.05245284 +- 0.00014780 Tm 16:09:20 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.05245 0.00015 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.05245 0.00015 2.05245 0.00000 16:09:20 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.05245 0.00015 SL = 2.0524528 +- 0.0001478 Tm^2/m^n 16:09:20 Magnet Strength Measurement Harmonic Number = 1 SL = 2.0524528 +- 0.0001478 Tm^2/m^n 16:09:22 Magnet Current, Imag = 650.2120 A Vtrans = 6.502120 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:09:24 Magnet Current, Imag = 650.2010 A Vtrans = 6.502010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:09:25 Magnet Current, Imag = 650.2300 A Vtrans = 6.502300 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:09:27 Magnet Current, Imag = 650.2230 A Vtrans = 6.502230 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:09:27 Magnet Current Measurement: Imag = 650.2165 +- 0.0110 A 16:09:27 Magnet current ramping to 600.0000 A... 16:09:50 Magnet Current, Imag = 600.1630 A Vtrans = 6.001630 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:09:52 Magnet Current, Imag = 600.1600 A Vtrans = 6.001600 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:09:53 Magnet Current, Imag = 600.1640 A Vtrans = 6.001640 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:09:55 Magnet Current, Imag = 600.1650 A Vtrans = 6.001650 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:09:55 Magnet Current Measurement: Imag = 600.1630 +- 0.0019 A 16:09:55 Magnetic Field Measurement Measuring the magnet strength... 16:09:55 Integrated Voltage Measurement... 16:10:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018904896 Vs 16:10:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019259103 Vs 16:10:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018909691 Vs 16:10:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019269063 Vs 16:10:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018904769 Vs 16:11:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019258961 Vs 16:11:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018901755 Vs 16:11:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019252224 Vs 16:11:23 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019082558 +- 0.000004424 Vs 16:11:23 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.019082558 +- 0.000004424 Vs BL = 1.90825577 +- 0.00044243 Tm 16:11:27 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.90826 0.00044 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.90826 0.00044 1.90826 0.00000 16:11:27 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.90826 0.00044 SL = 1.9082558 +- 0.0004424 Tm^2/m^n 16:11:27 Magnet Strength Measurement Harmonic Number = 1 SL = 1.9082558 +- 0.0004424 Tm^2/m^n 16:11:28 Magnet Current, Imag = 600.1780 A Vtrans = 6.001780 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:11:30 Magnet Current, Imag = 600.1800 A Vtrans = 6.001800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:11:31 Magnet Current, Imag = 600.1840 A Vtrans = 6.001840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:11:33 Magnet Current, Imag = 600.1780 A Vtrans = 6.001780 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:11:33 Magnet Current Measurement: Imag = 600.1800 +- 0.0024 A 16:11:33 Magnet current ramping to 550.0000 A... 16:11:56 Magnet Current, Imag = 550.1540 A Vtrans = 5.501540 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:11:58 Magnet Current, Imag = 550.1300 A Vtrans = 5.501300 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:12:00 Magnet Current, Imag = 550.1290 A Vtrans = 5.501290 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:12:01 Magnet Current, Imag = 550.1360 A Vtrans = 5.501360 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:12:01 Magnet Current Measurement: Imag = 550.1372 +- 0.0100 A 16:12:01 Magnetic Field Measurement Measuring the magnet strength... 16:12:01 Integrated Voltage Measurement... 16:12:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017363535 Vs 16:12:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017723457 Vs 16:12:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017354715 Vs 16:12:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017714719 Vs 16:12:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017364514 Vs 16:13:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017716237 Vs 16:13:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017358610 Vs 16:13:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017733182 Vs 16:13:30 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017541121 +- 0.000004184 Vs 16:13:30 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.017541121 +- 0.000004184 Vs BL = 1.75411210 +- 0.00041837 Tm 16:13:33 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.75411 0.00042 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.75411 0.00042 1.75411 0.00000 16:13:33 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.75411 0.00042 SL = 1.7541121 +- 0.0004184 Tm^2/m^n 16:13:33 Magnet Strength Measurement Harmonic Number = 1 SL = 1.7541121 +- 0.0004184 Tm^2/m^n 16:13:35 Magnet Current, Imag = 550.1330 A Vtrans = 5.501330 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:13:37 Magnet Current, Imag = 550.1390 A Vtrans = 5.501390 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:13:38 Magnet Current, Imag = 550.1380 A Vtrans = 5.501380 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:13:40 Magnet Current, Imag = 550.1080 A Vtrans = 5.501080 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:13:40 Magnet Current Measurement: Imag = 550.1295 +- 0.0126 A 16:13:40 Magnet current ramping to 500.0000 A... 16:14:03 Magnet Current, Imag = 500.1800 A Vtrans = 5.001800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:14:05 Magnet Current, Imag = 500.1680 A Vtrans = 5.001680 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:14:06 Magnet Current, Imag = 500.1700 A Vtrans = 5.001700 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:14:08 Magnet Current, Imag = 500.1700 A Vtrans = 5.001700 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:14:08 Magnet Current Measurement: Imag = 500.1720 +- 0.0047 A 16:14:08 Magnetic Field Measurement Measuring the magnet strength... 16:14:08 Integrated Voltage Measurement... 16:14:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015789075 Vs 16:14:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016144263 Vs 16:14:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015778413 Vs 16:14:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016138114 Vs 16:15:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015785377 Vs 16:15:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016147841 Vs 16:15:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015783663 Vs 16:15:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016139371 Vs 16:15:38 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015963265 +- 0.000003565 Vs 16:15:38 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.015963265 +- 0.000003565 Vs BL = 1.59632646 +- 0.00035653 Tm 16:15:41 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.59633 0.00036 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.59633 0.00036 1.59633 0.00000 16:15:41 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.59633 0.00036 SL = 1.5963265 +- 0.0003565 Tm^2/m^n 16:15:41 Magnet Strength Measurement Harmonic Number = 1 SL = 1.5963265 +- 0.0003565 Tm^2/m^n 16:15:43 Magnet Current, Imag = 500.1620 A Vtrans = 5.001620 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:15:46 Magnet Current, Imag = 500.1320 A Vtrans = 5.001320 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:15:47 Magnet Current, Imag = 500.1630 A Vtrans = 5.001630 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:15:49 Magnet Current, Imag = 500.1450 A Vtrans = 5.001450 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:15:49 Magnet Current Measurement: Imag = 500.1505 +- 0.0129 A 16:15:49 Magnet current ramping to 450.0000 A... 16:16:12 Magnet Current, Imag = 450.1580 A Vtrans = 4.501580 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:16:14 Magnet Current, Imag = 450.1410 A Vtrans = 4.501410 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:16:15 Magnet Current, Imag = 450.1530 A Vtrans = 4.501530 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:16:17 Magnet Current, Imag = 450.1400 A Vtrans = 4.501400 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:16:17 Magnet Current Measurement: Imag = 450.1480 +- 0.0077 A 16:16:17 Magnetic Field Measurement Measuring the magnet strength... 16:16:17 Integrated Voltage Measurement... 16:16:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014189376 Vs 16:16:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014553267 Vs 16:16:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014196514 Vs 16:17:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014547575 Vs 16:17:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014201581 Vs 16:17:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014553095 Vs 16:17:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014203579 Vs 16:17:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014554845 Vs 16:17:46 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014374979 +- 0.000003372 Vs 16:17:46 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.014374979 +- 0.000003372 Vs BL = 1.43749792 +- 0.00033717 Tm 16:17:49 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.43750 0.00034 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.43750 0.00034 1.43750 0.00000 16:17:49 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.43750 0.00034 SL = 1.4374979 +- 0.0003372 Tm^2/m^n 16:17:49 Magnet Strength Measurement Harmonic Number = 1 SL = 1.4374979 +- 0.0003372 Tm^2/m^n 16:17:50 Magnet Current, Imag = 450.0880 A Vtrans = 4.500880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:17:52 Magnet Current, Imag = 450.1030 A Vtrans = 4.501030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:17:54 Magnet Current, Imag = 450.1160 A Vtrans = 4.501160 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:17:55 Magnet Current, Imag = 450.1200 A Vtrans = 4.501200 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:17:55 Magnet Current Measurement: Imag = 450.1068 +- 0.0125 A 16:17:56 Magnet current ramping to 400.0000 A... 16:18:19 Magnet Current, Imag = 400.0650 A Vtrans = 4.000650 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:18:20 Magnet Current, Imag = 400.0730 A Vtrans = 4.000730 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:18:22 Magnet Current, Imag = 400.0710 A Vtrans = 4.000710 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:18:23 Magnet Current, Imag = 400.0610 A Vtrans = 4.000610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:18:23 Magnet Current Measurement: Imag = 400.0675 +- 0.0048 A 16:18:23 Magnetic Field Measurement Measuring the magnet strength... 16:18:24 Integrated Voltage Measurement... 16:18:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012604509 Vs 16:18:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012956287 Vs 16:18:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012591437 Vs 16:19:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012958211 Vs 16:19:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012610207 Vs 16:19:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012967959 Vs 16:19:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012608351 Vs 16:19:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012966884 Vs 16:19:52 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012782981 +- 0.000005743 Vs 16:19:52 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.012782981 +- 0.000005743 Vs BL = 1.27829807 +- 0.00057433 Tm 16:19:55 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.27830 0.00057 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.27830 0.00057 1.27830 0.00000 16:19:55 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.27830 0.00057 SL = 1.2782981 +- 0.0005743 Tm^2/m^n 16:19:55 Magnet Strength Measurement Harmonic Number = 1 SL = 1.2782981 +- 0.0005743 Tm^2/m^n 16:19:57 Magnet Current, Imag = 400.0870 A Vtrans = 4.000870 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:19:59 Magnet Current, Imag = 400.0890 A Vtrans = 4.000890 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:20:00 Magnet Current, Imag = 400.1010 A Vtrans = 4.001010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:20:02 Magnet Current, Imag = 400.0850 A Vtrans = 4.000850 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:20:02 Magnet Current Measurement: Imag = 400.0905 +- 0.0062 A 16:20:32 Magnet current ramping to 0.0000 A...