SLAC Magnetic Measurements Date: 07-26-2001 Time: 12:15:42 Project: spear3 Magnet Type: gdipole Magnet Name: 145d-011 Serial Number: Run Number: 8 Measurement Device: stretched wire Operator: jy Comment: BL vs. I, mains Standardization: 1 cycles from 0.0 A to 770.0 A to 0.0 A Test Currents (A): 50.0 100.0 150.0 200.0 250.0 300.0 350.0 400.0 450.0 500.0 525.0 550.0 575.0 600.0 625.0 650.0 675.0 700.0 650.0 600.0 550.0 500.0 450.0 400.0 12:15:49 Initial Zero Current Measurement, Imag_zero = 0.0000 A 12:15:49 Magnet current ramping to 15.0000 A... 12:16:21 Magnet current ramping to 770.0000 A... 12:20:34 Magnet current ramping to 0.0000 A... 12:25:23 Magnet current ramping to 50.0000 A... 12:25:47 Magnet Current, Imag = 50.5601 A Vtrans = 0.505601 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:25:48 Magnet Current, Imag = 51.6748 A Vtrans = 0.516748 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:25:49 Magnet Current, Imag = 49.1627 A Vtrans = 0.491627 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:25:51 Magnet Current, Imag = 49.9037 A Vtrans = 0.499037 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:25:51 Magnet Current Measurement: Imag = 50.3253 +- 0.9227 A 12:25:51 Magnetic Field Measurement Measuring the magnet strength... 12:25:51 Integrated Voltage Measurement... 12:26:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005309411 Vs 12:26:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.003738892 Vs 12:26:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005306744 Vs 12:26:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.003747590 Vs 12:26:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005311662 Vs 12:26:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.003746386 Vs 12:27:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005300929 Vs 12:27:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.003738466 Vs 12:27:19 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000782177 +- 0.000002084 Vs 12:27:20 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000782177 +- 0.000002084 Vs BL = 0.07821766 +- 0.00020838 Tm 12:27:23 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.07822 0.00021 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.07822 0.00021 0.07822 0.00000 12:27:23 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.07822 0.00021 SL = 0.0782177 +- 0.0002084 Tm^2/m^n 12:27:23 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0782177 +- 0.0002084 Tm^2/m^n 12:27:24 Magnet Current, Imag = 50.0081 A Vtrans = 0.500081 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:27:26 Magnet Current, Imag = 50.0118 A Vtrans = 0.500118 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:27:27 Magnet Current, Imag = 50.0384 A Vtrans = 0.500384 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:27:29 Magnet Current, Imag = 50.0263 A Vtrans = 0.500263 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:27:29 Magnet Current Measurement: Imag = 50.0211 +- 0.0121 A 12:27:29 Magnet current ramping to 100.0000 A... 12:27:52 Magnet Current, Imag = 100.0731 A Vtrans = 1.000731 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:27:53 Magnet Current, Imag = 100.0457 A Vtrans = 1.000457 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:27:55 Magnet Current, Imag = 100.0440 A Vtrans = 1.000440 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:27:56 Magnet Current, Imag = 100.0476 A Vtrans = 1.000476 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:27:56 Magnet Current Measurement: Imag = 100.0526 +- 0.0119 A 12:27:56 Magnetic Field Measurement Measuring the magnet strength... 12:27:56 Integrated Voltage Measurement... 13:27:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000000000 Vs 13:27:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003367683 Vs 13:27:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003003206 Vs 13:28:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003362403 Vs 13:28:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003004123 Vs 13:28:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003339507 Vs 13:28:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003011959 Vs 13:28:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003351196 Vs 13:28:47 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002805010 +- 0.000647321 Vs 13:28:47 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.002805010 +- 0.000647321 Vs BL = 0.28050097 +- 0.06473207 Tm 13:28:50 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.28050 0.06473 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.28050 0.06473 0.28050 0.00000 13:28:50 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.28050 0.06473 SL = 0.2805010 +- 0.0647321 Tm^2/m^n 13:28:50 Magnet Strength Measurement Harmonic Number = 1 SL = 0.2805010 +- 0.0647321 Tm^2/m^n 13:28:52 Magnet Current, Imag = 99.9465 A Vtrans = 0.999465 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:28:53 Magnet Current, Imag = 99.9469 A Vtrans = 0.999469 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:28:55 Magnet Current, Imag = 99.9285 A Vtrans = 0.999285 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:28:56 Magnet Current, Imag = 99.9453 A Vtrans = 0.999453 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:28:56 Magnet Current Measurement: Imag = 99.9418 +- 0.0077 A 13:28:56 Magnet current ramping to 150.0000 A... 13:29:19 Magnet Current, Imag = 149.9686 A Vtrans = 1.499686 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:29:21 Magnet Current, Imag = 149.9978 A Vtrans = 1.499978 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:29:22 Magnet Current, Imag = 150.0025 A Vtrans = 1.500025 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:29:23 Magnet Current, Imag = 149.9837 A Vtrans = 1.499837 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:29:24 Magnet Current Measurement: Imag = 149.9881 +- 0.0132 A 13:29:24 Magnetic Field Measurement Measuring the magnet strength... 13:29:24 Integrated Voltage Measurement... 13:29:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004603567 Vs 13:29:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004941086 Vs 13:29:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004585569 Vs 13:30:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004948872 Vs 13:30:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004600441 Vs 13:30:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004962679 Vs 13:30:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004600810 Vs 13:30:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004950635 Vs 13:30:52 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004774207 +- 0.000005213 Vs 13:30:52 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.004774207 +- 0.000005213 Vs BL = 0.47742073 +- 0.00052130 Tm 13:30:55 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.47742 0.00052 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.47742 0.00052 0.47742 0.00000 13:30:55 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.47742 0.00052 SL = 0.4774207 +- 0.0005213 Tm^2/m^n 13:30:55 Magnet Strength Measurement Harmonic Number = 1 SL = 0.4774207 +- 0.0005213 Tm^2/m^n 13:30:57 Magnet Current, Imag = 149.9731 A Vtrans = 1.499731 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:30:58 Magnet Current, Imag = 149.9756 A Vtrans = 1.499756 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:31:00 Magnet Current, Imag = 149.9938 A Vtrans = 1.499938 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:31:01 Magnet Current, Imag = 150.0024 A Vtrans = 1.500024 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:31:02 Magnet Current Measurement: Imag = 149.9862 +- 0.0123 A 13:31:02 Magnet current ramping to 200.0000 A... 13:31:25 Magnet Current, Imag = 199.9811 A Vtrans = 1.999811 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:31:26 Magnet Current, Imag = 199.9764 A Vtrans = 1.999764 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:31:27 Magnet Current, Imag = 199.9407 A Vtrans = 1.999407 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:31:29 Magnet Current, Imag = 199.9565 A Vtrans = 1.999565 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:31:29 Magnet Current Measurement: Imag = 199.9637 +- 0.0162 A 13:31:29 Magnetic Field Measurement Measuring the magnet strength... 13:31:29 Integrated Voltage Measurement... 13:31:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006187453 Vs 13:31:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006549167 Vs 13:32:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006183779 Vs 13:32:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006546281 Vs 13:32:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006185119 Vs 13:32:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006552604 Vs 13:32:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006180429 Vs 13:32:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006547061 Vs 13:32:57 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006366487 +- 0.000002156 Vs 13:32:58 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.006366487 +- 0.000002156 Vs BL = 0.63664867 +- 0.00021565 Tm 13:33:01 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.63665 0.00022 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.63665 0.00022 0.63665 0.00000 13:33:01 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.63665 0.00022 SL = 0.6366487 +- 0.0002156 Tm^2/m^n 13:33:01 Magnet Strength Measurement Harmonic Number = 1 SL = 0.6366487 +- 0.0002156 Tm^2/m^n 13:33:02 Magnet Current, Imag = 199.9917 A Vtrans = 1.999917 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:33:04 Magnet Current, Imag = 199.9662 A Vtrans = 1.999662 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:33:05 Magnet Current, Imag = 199.9650 A Vtrans = 1.999650 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:33:07 Magnet Current, Imag = 199.9667 A Vtrans = 1.999667 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:33:07 Magnet Current Measurement: Imag = 199.9724 +- 0.0112 A 13:33:07 Magnet current ramping to 250.0000 A... 13:33:30 Magnet Current, Imag = 250.0182 A Vtrans = 2.500182 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:33:31 Magnet Current, Imag = 250.0231 A Vtrans = 2.500231 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:33:33 Magnet Current, Imag = 250.0073 A Vtrans = 2.500073 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:33:34 Magnet Current, Imag = 249.9958 A Vtrans = 2.499958 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:33:34 Magnet Current Measurement: Imag = 250.0111 +- 0.0105 A 13:33:34 Magnetic Field Measurement Measuring the magnet strength... 13:33:34 Integrated Voltage Measurement... 13:33:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007769760 Vs 13:33:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008143066 Vs 13:34:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007797094 Vs 13:34:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008139127 Vs 13:34:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007776197 Vs 13:34:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008124481 Vs 13:34:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007770110 Vs 13:35:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008133518 Vs 13:35:03 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007956669 +- 0.000006975 Vs 13:35:03 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.007956669 +- 0.000006975 Vs BL = 0.79566691 +- 0.00069751 Tm 13:35:06 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.79567 0.00070 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.79567 0.00070 0.79567 0.00000 13:35:06 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.79567 0.00070 SL = 0.7956669 +- 0.0006975 Tm^2/m^n 13:35:06 Magnet Strength Measurement Harmonic Number = 1 SL = 0.7956669 +- 0.0006975 Tm^2/m^n 13:35:08 Magnet Current, Imag = 250.0268 A Vtrans = 2.500268 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:35:09 Magnet Current, Imag = 250.0185 A Vtrans = 2.500185 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:35:11 Magnet Current, Imag = 250.0210 A Vtrans = 2.500210 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:35:12 Magnet Current, Imag = 250.0032 A Vtrans = 2.500032 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:35:12 Magnet Current Measurement: Imag = 250.0174 +- 0.0087 A 13:35:12 Magnet current ramping to 300.0000 A... 13:35:35 Magnet Current, Imag = 300.0297 A Vtrans = 3.000297 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:35:37 Magnet Current, Imag = 300.0328 A Vtrans = 3.000328 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:35:38 Magnet Current, Imag = 300.0355 A Vtrans = 3.000355 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:35:40 Magnet Current, Imag = 300.0579 A Vtrans = 3.000579 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:35:40 Magnet Current Measurement: Imag = 300.0390 +- 0.0111 A 13:35:40 Magnetic Field Measurement Measuring the magnet strength... 13:35:40 Integrated Voltage Measurement... 13:35:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009376907 Vs 13:36:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009744632 Vs 13:36:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009376040 Vs 13:36:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009742913 Vs 13:36:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009366861 Vs 13:36:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009733848 Vs 13:36:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009383663 Vs 13:37:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009750906 Vs 13:37:08 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009559471 +- 0.000006038 Vs 13:37:08 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.009559471 +- 0.000006038 Vs BL = 0.95594713 +- 0.00060385 Tm 13:37:12 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.95595 0.00060 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.95595 0.00060 0.95595 0.00000 13:37:12 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.95595 0.00060 SL = 0.9559471 +- 0.0006038 Tm^2/m^n 13:37:12 Magnet Strength Measurement Harmonic Number = 1 SL = 0.9559471 +- 0.0006038 Tm^2/m^n 13:37:13 Magnet Current, Imag = 300.0364 A Vtrans = 3.000364 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:37:15 Magnet Current, Imag = 300.0161 A Vtrans = 3.000161 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:37:16 Magnet Current, Imag = 300.0244 A Vtrans = 3.000244 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:37:18 Magnet Current, Imag = 300.0609 A Vtrans = 3.000609 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:37:18 Magnet Current Measurement: Imag = 300.0344 +- 0.0169 A 13:37:18 Magnet current ramping to 350.0000 A... 13:37:41 Magnet Current, Imag = 350.0630 A Vtrans = 3.500630 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:37:43 Magnet Current, Imag = 350.0770 A Vtrans = 3.500770 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:37:45 Magnet Current, Imag = 350.0800 A Vtrans = 3.500800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:37:47 Magnet Current, Imag = 350.0790 A Vtrans = 3.500790 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:37:47 Magnet Current Measurement: Imag = 350.0747 +- 0.0069 A 13:37:47 Magnetic Field Measurement Measuring the magnet strength... 13:37:48 Integrated Voltage Measurement... 13:38:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010972563 Vs 13:38:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011322655 Vs 13:38:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010970164 Vs 13:38:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011320653 Vs 13:38:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010965078 Vs 13:38:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011335265 Vs 13:39:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010952782 Vs 13:39:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011329211 Vs 13:39:16 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011146046 +- 0.000003368 Vs 13:39:16 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.011146046 +- 0.000003368 Vs BL = 1.11460464 +- 0.00033679 Tm 13:39:19 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.11460 0.00034 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.11460 0.00034 1.11460 0.00000 13:39:19 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.11460 0.00034 SL = 1.1146046 +- 0.0003368 Tm^2/m^n 13:39:19 Magnet Strength Measurement Harmonic Number = 1 SL = 1.1146046 +- 0.0003368 Tm^2/m^n 13:39:21 Magnet Current, Imag = 350.0750 A Vtrans = 3.500750 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:39:23 Magnet Current, Imag = 350.0560 A Vtrans = 3.500560 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:39:25 Magnet Current, Imag = 350.0760 A Vtrans = 3.500760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:39:27 Magnet Current, Imag = 350.0790 A Vtrans = 3.500790 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:39:27 Magnet Current Measurement: Imag = 350.0715 +- 0.0091 A 13:39:27 Magnet current ramping to 400.0000 A... 13:39:51 Magnet Current, Imag = 400.0740 A Vtrans = 4.000740 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:39:52 Magnet Current, Imag = 400.0850 A Vtrans = 4.000850 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:39:54 Magnet Current, Imag = 400.0700 A Vtrans = 4.000700 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:39:56 Magnet Current, Imag = 400.0590 A Vtrans = 4.000590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:39:56 Magnet Current Measurement: Imag = 400.0720 +- 0.0093 A 13:39:56 Magnetic Field Measurement Measuring the magnet strength... 13:39:56 Integrated Voltage Measurement... 13:40:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012551733 Vs 13:40:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012901385 Vs 13:40:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012558861 Vs 13:40:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012916145 Vs 13:40:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012553977 Vs 13:41:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012911161 Vs 13:41:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012563984 Vs 13:41:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012915089 Vs 13:41:24 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012734042 +- 0.000005008 Vs 13:41:25 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.012734042 +- 0.000005008 Vs BL = 1.27340418 +- 0.00050082 Tm 13:41:28 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.27340 0.00050 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.27340 0.00050 1.27340 0.00000 13:41:28 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.27340 0.00050 SL = 1.2734042 +- 0.0005008 Tm^2/m^n 13:41:28 Magnet Strength Measurement Harmonic Number = 1 SL = 1.2734042 +- 0.0005008 Tm^2/m^n 13:41:29 Magnet Current, Imag = 400.0460 A Vtrans = 4.000460 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:41:31 Magnet Current, Imag = 400.0610 A Vtrans = 4.000610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:41:33 Magnet Current, Imag = 400.0580 A Vtrans = 4.000580 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:41:34 Magnet Current, Imag = 400.0540 A Vtrans = 4.000540 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:41:34 Magnet Current Measurement: Imag = 400.0548 +- 0.0056 A 13:41:35 Magnet current ramping to 450.0000 A... 13:41:58 Magnet Current, Imag = 450.0340 A Vtrans = 4.500340 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:41:59 Magnet Current, Imag = 450.0590 A Vtrans = 4.500590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:42:01 Magnet Current, Imag = 450.0800 A Vtrans = 4.500800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:42:02 Magnet Current, Imag = 450.1030 A Vtrans = 4.501030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:42:03 Magnet Current Measurement: Imag = 450.0690 +- 0.0255 A 13:42:03 Magnetic Field Measurement Measuring the magnet strength... 13:42:03 Integrated Voltage Measurement... 13:42:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014160011 Vs 13:42:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014521287 Vs 13:42:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014141404 Vs 13:42:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014506263 Vs 13:42:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014136166 Vs 13:43:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014516749 Vs 13:43:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014145431 Vs 13:43:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014498883 Vs 13:43:32 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014328274 +- 0.000007307 Vs 13:43:32 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.014328274 +- 0.000007307 Vs BL = 1.43282744 +- 0.00073070 Tm 13:43:35 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.43283 0.00073 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.43283 0.00073 1.43283 0.00000 13:43:35 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.43283 0.00073 SL = 1.4328274 +- 0.0007307 Tm^2/m^n 13:43:35 Magnet Strength Measurement Harmonic Number = 1 SL = 1.4328274 +- 0.0007307 Tm^2/m^n 13:43:37 Magnet Current, Imag = 450.1080 A Vtrans = 4.501080 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:43:38 Magnet Current, Imag = 450.0730 A Vtrans = 4.500730 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:43:40 Magnet Current, Imag = 450.0560 A Vtrans = 4.500560 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:43:42 Magnet Current, Imag = 450.0910 A Vtrans = 4.500910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:43:42 Magnet Current Measurement: Imag = 450.0820 +- 0.0195 A 13:43:42 Magnet current ramping to 500.0000 A... 13:44:05 Magnet Current, Imag = 500.1480 A Vtrans = 5.001480 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:44:07 Magnet Current, Imag = 500.1360 A Vtrans = 5.001360 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:44:08 Magnet Current, Imag = 500.1210 A Vtrans = 5.001210 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:44:10 Magnet Current, Imag = 500.1430 A Vtrans = 5.001430 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:44:10 Magnet Current Measurement: Imag = 500.1370 +- 0.0102 A 13:44:10 Magnetic Field Measurement Measuring the magnet strength... 13:44:10 Integrated Voltage Measurement... 13:44:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015716065 Vs 13:44:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016087803 Vs 13:44:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015737937 Vs 13:44:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016084479 Vs 13:45:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015736670 Vs 13:45:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016091313 Vs 13:45:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015708117 Vs 13:45:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016088719 Vs 13:45:39 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015906388 +- 0.000006411 Vs 13:45:39 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.015906388 +- 0.000006411 Vs BL = 1.59063881 +- 0.00064110 Tm 13:45:42 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.59064 0.00064 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.59064 0.00064 1.59064 0.00000 13:45:42 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.59064 0.00064 SL = 1.5906388 +- 0.0006411 Tm^2/m^n 13:45:42 Magnet Strength Measurement Harmonic Number = 1 SL = 1.5906388 +- 0.0006411 Tm^2/m^n 13:45:44 Magnet Current, Imag = 500.1410 A Vtrans = 5.001410 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:45:46 Magnet Current, Imag = 500.1110 A Vtrans = 5.001110 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:45:47 Magnet Current, Imag = 500.1150 A Vtrans = 5.001150 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:45:49 Magnet Current, Imag = 500.1430 A Vtrans = 5.001430 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:45:49 Magnet Current Measurement: Imag = 500.1275 +- 0.0146 A 13:45:49 Magnet current ramping to 525.0000 A... 13:46:05 Magnet Current, Imag = 525.1190 A Vtrans = 5.251190 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:46:06 Magnet Current, Imag = 525.1390 A Vtrans = 5.251390 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:46:08 Magnet Current, Imag = 525.1670 A Vtrans = 5.251670 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:46:10 Magnet Current, Imag = 525.1720 A Vtrans = 5.251720 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:46:10 Magnet Current Measurement: Imag = 525.1492 +- 0.0215 A 13:46:10 Magnetic Field Measurement Measuring the magnet strength... 13:46:10 Integrated Voltage Measurement... 13:46:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016505876 Vs 13:46:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016872895 Vs 13:46:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016529008 Vs 13:46:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016877834 Vs 13:47:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016509385 Vs 13:47:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016879353 Vs 13:47:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016517928 Vs 13:47:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016887395 Vs 13:47:39 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016697459 +- 0.000005860 Vs 13:47:39 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.016697459 +- 0.000005860 Vs BL = 1.66974592 +- 0.00058597 Tm 13:47:42 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.66975 0.00059 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.66975 0.00059 1.66975 0.00000 13:47:42 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.66975 0.00059 SL = 1.6697459 +- 0.0005860 Tm^2/m^n 13:47:42 Magnet Strength Measurement Harmonic Number = 1 SL = 1.6697459 +- 0.0005860 Tm^2/m^n 13:47:44 Magnet Current, Imag = 525.1420 A Vtrans = 5.251420 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:47:45 Magnet Current, Imag = 525.1590 A Vtrans = 5.251590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:47:47 Magnet Current, Imag = 525.1630 A Vtrans = 5.251630 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:47:48 Magnet Current, Imag = 525.1670 A Vtrans = 5.251670 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:47:48 Magnet Current Measurement: Imag = 525.1577 +- 0.0095 A 13:47:49 Magnet current ramping to 550.0000 A... 13:48:04 Magnet Current, Imag = 550.0780 A Vtrans = 5.500780 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:48:06 Magnet Current, Imag = 550.1070 A Vtrans = 5.501070 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:48:08 Magnet Current, Imag = 550.1480 A Vtrans = 5.501480 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:48:09 Magnet Current, Imag = 550.1460 A Vtrans = 5.501460 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:48:09 Magnet Current Measurement: Imag = 550.1198 +- 0.0291 A 13:48:09 Magnetic Field Measurement Measuring the magnet strength... 13:48:10 Integrated Voltage Measurement... 13:48:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017301567 Vs 13:48:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017656929 Vs 13:48:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017291236 Vs 13:48:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017650373 Vs 13:49:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017296228 Vs 13:49:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017675816 Vs 13:49:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017282129 Vs 13:49:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017662658 Vs 13:49:38 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017477117 +- 0.000006041 Vs 13:49:38 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.017477117 +- 0.000006041 Vs BL = 1.74771170 +- 0.00060414 Tm 13:49:41 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.74771 0.00060 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.74771 0.00060 1.74771 0.00000 13:49:41 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.74771 0.00060 SL = 1.7477117 +- 0.0006041 Tm^2/m^n 13:49:42 Magnet Strength Measurement Harmonic Number = 1 SL = 1.7477117 +- 0.0006041 Tm^2/m^n 13:49:43 Magnet Current, Imag = 550.1510 A Vtrans = 5.501510 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:49:45 Magnet Current, Imag = 550.1250 A Vtrans = 5.501250 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:49:46 Magnet Current, Imag = 550.0850 A Vtrans = 5.500850 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:49:48 Magnet Current, Imag = 550.1150 A Vtrans = 5.501150 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:49:48 Magnet Current Measurement: Imag = 550.1190 +- 0.0236 A 13:49:48 Magnet current ramping to 575.0000 A... 13:50:04 Magnet Current, Imag = 575.1250 A Vtrans = 5.751250 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:50:05 Magnet Current, Imag = 575.1620 A Vtrans = 5.751620 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:50:07 Magnet Current, Imag = 575.1550 A Vtrans = 5.751550 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:50:09 Magnet Current, Imag = 575.1630 A Vtrans = 5.751630 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:50:09 Magnet Current Measurement: Imag = 575.1513 +- 0.0155 A 13:50:09 Magnetic Field Measurement Measuring the magnet strength... 13:50:09 Integrated Voltage Measurement... 13:50:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018063347 Vs 13:50:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018445723 Vs 13:50:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018076255 Vs 13:50:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018436840 Vs 13:51:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018078149 Vs 13:51:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018429814 Vs 13:51:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018066281 Vs 13:51:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.018433412 Vs 13:51:38 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018253728 +- 0.000002436 Vs 13:51:38 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.018253728 +- 0.000002436 Vs BL = 1.82537277 +- 0.00024356 Tm 13:51:41 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.82537 0.00024 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.82537 0.00024 1.82537 0.00000 13:51:41 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.82537 0.00024 SL = 1.8253728 +- 0.0002436 Tm^2/m^n 13:51:41 Magnet Strength Measurement Harmonic Number = 1 SL = 1.8253728 +- 0.0002436 Tm^2/m^n 13:51:43 Magnet Current, Imag = 575.1750 A Vtrans = 5.751750 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:51:45 Magnet Current, Imag = 575.1460 A Vtrans = 5.751460 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:51:46 Magnet Current, Imag = 575.1700 A Vtrans = 5.751700 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:51:48 Magnet Current, Imag = 575.1780 A Vtrans = 5.751780 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:51:48 Magnet Current Measurement: Imag = 575.1672 +- 0.0126 A 13:51:48 Magnet current ramping to 600.0000 A... 13:52:04 Magnet Current, Imag = 600.1690 A Vtrans = 6.001690 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:52:05 Magnet Current, Imag = 600.1820 A Vtrans = 6.001820 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:52:07 Magnet Current, Imag = 600.1610 A Vtrans = 6.001610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:52:08 Magnet Current, Imag = 600.1640 A Vtrans = 6.001640 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:52:09 Magnet Current Measurement: Imag = 600.1690 +- 0.0080 A 13:52:09 Magnetic Field Measurement Measuring the magnet strength... 13:52:09 Integrated Voltage Measurement... 13:52:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018834173 Vs 13:52:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019204431 Vs 13:52:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018832947 Vs 13:52:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019182267 Vs 13:53:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018840031 Vs 13:53:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019196132 Vs 13:53:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018829215 Vs 13:53:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019190149 Vs 13:53:37 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019013668 +- 0.000005095 Vs 13:53:38 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.019013668 +- 0.000005095 Vs BL = 1.90136681 +- 0.00050952 Tm 13:53:41 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.90137 0.00051 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.90137 0.00051 1.90137 0.00000 13:53:41 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.90137 0.00051 SL = 1.9013668 +- 0.0005095 Tm^2/m^n 13:53:41 Magnet Strength Measurement Harmonic Number = 1 SL = 1.9013668 +- 0.0005095 Tm^2/m^n 13:53:42 Magnet Current, Imag = 600.1500 A Vtrans = 6.001500 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:53:44 Magnet Current, Imag = 600.1460 A Vtrans = 6.001460 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:53:46 Magnet Current, Imag = 600.1560 A Vtrans = 6.001560 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:53:47 Magnet Current, Imag = 600.1790 A Vtrans = 6.001790 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:53:47 Magnet Current Measurement: Imag = 600.1577 +- 0.0128 A 13:53:47 Magnet current ramping to 625.0000 A... 13:54:03 Magnet Current, Imag = 625.1980 A Vtrans = 6.251980 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:54:05 Magnet Current, Imag = 625.1730 A Vtrans = 6.251730 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:54:06 Magnet Current, Imag = 625.1840 A Vtrans = 6.251840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:54:08 Magnet Current, Imag = 625.2060 A Vtrans = 6.252060 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:54:08 Magnet Current Measurement: Imag = 625.1902 +- 0.0127 A 13:54:08 Magnetic Field Measurement Measuring the magnet strength... 13:54:08 Integrated Voltage Measurement... 13:54:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019577555 Vs 13:54:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019928845 Vs 13:54:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019569269 Vs 13:54:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019932807 Vs 13:55:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019582159 Vs 13:55:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019938645 Vs 13:55:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019583885 Vs 13:55:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019938281 Vs 13:55:37 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019756431 +- 0.000004386 Vs 13:55:37 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.019756431 +- 0.000004386 Vs BL = 1.97564308 +- 0.00043856 Tm 13:55:40 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.97564 0.00044 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.97564 0.00044 1.97564 0.00000 13:55:40 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.97564 0.00044 SL = 1.9756431 +- 0.0004386 Tm^2/m^n 13:55:40 Magnet Strength Measurement Harmonic Number = 1 SL = 1.9756431 +- 0.0004386 Tm^2/m^n 13:55:42 Magnet Current, Imag = 625.2590 A Vtrans = 6.252590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:55:43 Magnet Current, Imag = 625.2500 A Vtrans = 6.252500 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:55:45 Magnet Current, Imag = 625.2410 A Vtrans = 6.252410 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:55:47 Magnet Current, Imag = 625.2280 A Vtrans = 6.252280 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:55:47 Magnet Current Measurement: Imag = 625.2445 +- 0.0115 A 13:55:47 Magnet current ramping to 650.0000 A... 13:56:02 Magnet Current, Imag = 650.2490 A Vtrans = 6.502490 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:56:04 Magnet Current, Imag = 650.2580 A Vtrans = 6.502580 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:56:06 Magnet Current, Imag = 650.1870 A Vtrans = 6.501870 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:56:07 Magnet Current, Imag = 650.2060 A Vtrans = 6.502060 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:56:07 Magnet Current Measurement: Imag = 650.2250 +- 0.0295 A 13:56:07 Magnetic Field Measurement Measuring the magnet strength... 13:56:08 Integrated Voltage Measurement... 13:56:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020295788 Vs 13:56:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020644437 Vs 13:56:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020277833 Vs 13:56:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020639617 Vs 13:57:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020298098 Vs 13:57:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020656908 Vs 13:57:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020296403 Vs 13:57:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020637166 Vs 13:57:36 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020468281 +- 0.000006745 Vs 13:57:36 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.020468281 +- 0.000006745 Vs BL = 2.04682813 +- 0.00067447 Tm 13:57:39 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.04683 0.00067 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.04683 0.00067 2.04683 0.00000 13:57:39 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.04683 0.00067 SL = 2.0468281 +- 0.0006745 Tm^2/m^n 13:57:40 Magnet Strength Measurement Harmonic Number = 1 SL = 2.0468281 +- 0.0006745 Tm^2/m^n 13:57:41 Magnet Current, Imag = 650.2160 A Vtrans = 6.502160 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:57:43 Magnet Current, Imag = 650.2520 A Vtrans = 6.502520 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:57:44 Magnet Current, Imag = 650.2430 A Vtrans = 6.502430 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:57:46 Magnet Current, Imag = 650.2100 A Vtrans = 6.502100 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:57:46 Magnet Current Measurement: Imag = 650.2302 +- 0.0177 A 13:57:46 Magnet current ramping to 675.0000 A... 13:58:02 Magnet Current, Imag = 675.2380 A Vtrans = 6.752380 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:58:03 Magnet Current, Imag = 675.2470 A Vtrans = 6.752470 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:58:05 Magnet Current, Imag = 675.1800 A Vtrans = 6.751800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:58:07 Magnet Current, Imag = 675.2240 A Vtrans = 6.752240 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:58:07 Magnet Current Measurement: Imag = 675.2223 +- 0.0257 A 13:58:07 Magnetic Field Measurement Measuring the magnet strength... 13:58:07 Integrated Voltage Measurement... 13:58:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020947505 Vs 13:58:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021303289 Vs 13:58:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020954529 Vs 13:58:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021303831 Vs 13:59:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020943233 Vs 13:59:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021307857 Vs 13:59:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020954052 Vs 13:59:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021297449 Vs 13:59:35 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021126468 +- 0.000001571 Vs 13:59:35 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.021126468 +- 0.000001571 Vs BL = 2.11264682 +- 0.00015707 Tm 13:59:39 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.11265 0.00016 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.11265 0.00016 2.11265 0.00000 13:59:39 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.11265 0.00016 SL = 2.1126468 +- 0.0001571 Tm^2/m^n 13:59:39 Magnet Strength Measurement Harmonic Number = 1 SL = 2.1126468 +- 0.0001571 Tm^2/m^n 13:59:40 Magnet Current, Imag = 675.1930 A Vtrans = 6.751930 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:59:42 Magnet Current, Imag = 675.2460 A Vtrans = 6.752460 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:59:44 Magnet Current, Imag = 675.2640 A Vtrans = 6.752640 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:59:45 Magnet Current, Imag = 675.2630 A Vtrans = 6.752630 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 13:59:45 Magnet Current Measurement: Imag = 675.2415 +- 0.0289 A 13:59:45 Magnet current ramping to 700.0000 A... 14:00:01 Magnet Current, Imag = 700.2620 A Vtrans = 7.002620 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:00:03 Magnet Current, Imag = 700.2660 A Vtrans = 7.002660 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:00:04 Magnet Current, Imag = 700.2530 A Vtrans = 7.002530 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:00:06 Magnet Current, Imag = 700.2190 A Vtrans = 7.002190 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:00:06 Magnet Current Measurement: Imag = 700.2500 +- 0.0185 A 14:00:06 Magnetic Field Measurement Measuring the magnet strength... 14:00:06 Integrated Voltage Measurement... 14:00:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021564543 Vs 14:00:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021939787 Vs 14:00:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021568784 Vs 14:00:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021910845 Vs 14:01:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021567347 Vs 14:01:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021937477 Vs 14:01:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021580189 Vs 14:01:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.021931875 Vs 14:01:34 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.021750106 +- 0.000006136 Vs 14:01:35 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.021750106 +- 0.000006136 Vs BL = 2.17501059 +- 0.00061357 Tm 14:01:38 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.17501 0.00061 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.17501 0.00061 2.17501 0.00000 14:01:38 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.17501 0.00061 SL = 2.1750106 +- 0.0006136 Tm^2/m^n 14:01:38 Magnet Strength Measurement Harmonic Number = 1 SL = 2.1750106 +- 0.0006136 Tm^2/m^n 14:01:39 Magnet Current, Imag = 700.2920 A Vtrans = 7.002920 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:01:41 Magnet Current, Imag = 700.2630 A Vtrans = 7.002630 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:01:43 Magnet Current, Imag = 700.2430 A Vtrans = 7.002430 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:01:44 Magnet Current, Imag = 700.2390 A Vtrans = 7.002390 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:01:44 Magnet Current Measurement: Imag = 700.2592 +- 0.0210 A 14:01:45 Magnet current ramping to 650.0000 A... 14:02:08 Magnet Current, Imag = 650.2200 A Vtrans = 6.502200 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:02:09 Magnet Current, Imag = 650.2120 A Vtrans = 6.502120 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:02:11 Magnet Current, Imag = 650.2100 A Vtrans = 6.502100 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:02:12 Magnet Current, Imag = 650.2250 A Vtrans = 6.502250 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:02:12 Magnet Current Measurement: Imag = 650.2167 +- 0.0061 A 14:02:12 Magnetic Field Measurement Measuring the magnet strength... 14:02:12 Integrated Voltage Measurement... 14:02:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020364830 Vs 14:02:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020738176 Vs 14:02:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020357012 Vs 14:02:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020739011 Vs 14:03:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020376707 Vs 14:03:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020723410 Vs 14:03:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020353007 Vs 14:03:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.020718530 Vs 14:03:41 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.020546335 +- 0.000006226 Vs 14:03:41 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.020546335 +- 0.000006226 Vs BL = 2.05463354 +- 0.00062256 Tm 14:03:44 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 2.05463 0.00062 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 2.05463 0.00062 2.05463 0.00000 14:03:44 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 2.05463 0.00062 SL = 2.0546335 +- 0.0006226 Tm^2/m^n 14:03:44 Magnet Strength Measurement Harmonic Number = 1 SL = 2.0546335 +- 0.0006226 Tm^2/m^n 14:03:46 Magnet Current, Imag = 650.2410 A Vtrans = 6.502410 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:03:48 Magnet Current, Imag = 650.2360 A Vtrans = 6.502360 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:03:49 Magnet Current, Imag = 650.2080 A Vtrans = 6.502080 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:03:51 Magnet Current, Imag = 650.2360 A Vtrans = 6.502360 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:03:51 Magnet Current Measurement: Imag = 650.2302 +- 0.0130 A 14:03:51 Magnet current ramping to 600.0000 A... 14:04:14 Magnet Current, Imag = 600.1650 A Vtrans = 6.001650 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:04:16 Magnet Current, Imag = 600.1550 A Vtrans = 6.001550 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:04:17 Magnet Current, Imag = 600.1580 A Vtrans = 6.001580 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:04:19 Magnet Current, Imag = 600.1170 A Vtrans = 6.001170 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:04:19 Magnet Current Measurement: Imag = 600.1487 +- 0.0187 A 14:04:19 Magnetic Field Measurement Measuring the magnet strength... 14:04:19 Integrated Voltage Measurement... 14:04:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018909986 Vs 14:04:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019274961 Vs 14:04:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018917201 Vs 14:05:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019268822 Vs 14:05:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018908259 Vs 14:05:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019280850 Vs 14:05:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.018918469 Vs 14:05:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.019241527 Vs 14:05:48 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.019090009 +- 0.000005830 Vs 14:05:48 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.019090009 +- 0.000005830 Vs BL = 1.90900094 +- 0.00058303 Tm 14:05:51 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.90900 0.00058 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.90900 0.00058 1.90900 0.00000 14:05:51 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.90900 0.00058 SL = 1.9090009 +- 0.0005830 Tm^2/m^n 14:05:51 Magnet Strength Measurement Harmonic Number = 1 SL = 1.9090009 +- 0.0005830 Tm^2/m^n 14:05:53 Magnet Current, Imag = 600.1350 A Vtrans = 6.001350 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:05:54 Magnet Current, Imag = 600.1500 A Vtrans = 6.001500 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:05:56 Magnet Current, Imag = 600.1660 A Vtrans = 6.001660 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:05:58 Magnet Current, Imag = 600.1940 A Vtrans = 6.001940 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:05:58 Magnet Current Measurement: Imag = 600.1612 +- 0.0219 A 14:05:58 Magnet current ramping to 550.0000 A... 14:06:21 Magnet Current, Imag = 550.1440 A Vtrans = 5.501440 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:06:23 Magnet Current, Imag = 550.1020 A Vtrans = 5.501020 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:06:24 Magnet Current, Imag = 550.0940 A Vtrans = 5.500940 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:06:26 Magnet Current, Imag = 550.0800 A Vtrans = 5.500800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:06:26 Magnet Current Measurement: Imag = 550.1050 +- 0.0239 A 14:06:26 Magnetic Field Measurement Measuring the magnet strength... 14:06:26 Integrated Voltage Measurement... 14:06:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017365771 Vs 14:06:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017729049 Vs 14:07:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017374123 Vs 14:07:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017728375 Vs 14:07:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017380888 Vs 14:07:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017725279 Vs 14:07:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017373538 Vs 14:07:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.017734343 Vs 14:07:55 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.017551421 +- 0.000002511 Vs 14:07:55 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.017551421 +- 0.000002511 Vs BL = 1.75514208 +- 0.00025113 Tm 14:07:58 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.75514 0.00025 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.75514 0.00025 1.75514 0.00000 14:07:58 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.75514 0.00025 SL = 1.7551421 +- 0.0002511 Tm^2/m^n 14:07:58 Magnet Strength Measurement Harmonic Number = 1 SL = 1.7551421 +- 0.0002511 Tm^2/m^n 14:08:00 Magnet Current, Imag = 550.1400 A Vtrans = 5.501400 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:08:01 Magnet Current, Imag = 550.1420 A Vtrans = 5.501420 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:08:03 Magnet Current, Imag = 550.1240 A Vtrans = 5.501240 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:08:05 Magnet Current, Imag = 550.1460 A Vtrans = 5.501460 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:08:05 Magnet Current Measurement: Imag = 550.1380 +- 0.0084 A 14:08:05 Magnet current ramping to 500.0000 A... 14:08:28 Magnet Current, Imag = 500.1880 A Vtrans = 5.001880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:08:30 Magnet Current, Imag = 500.1880 A Vtrans = 5.001880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:08:31 Magnet Current, Imag = 500.1810 A Vtrans = 5.001810 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:08:33 Magnet Current, Imag = 500.1730 A Vtrans = 5.001730 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:08:33 Magnet Current Measurement: Imag = 500.1825 +- 0.0062 A 14:08:33 Magnetic Field Measurement Measuring the magnet strength... 14:08:33 Integrated Voltage Measurement... 14:08:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015792593 Vs 14:08:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016162388 Vs 14:09:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015795052 Vs 14:09:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016149297 Vs 14:09:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015799687 Vs 14:09:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016160249 Vs 14:09:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015786400 Vs 14:10:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016137540 Vs 14:10:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015972901 +- 0.000006910 Vs 14:10:02 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.015972901 +- 0.000006910 Vs BL = 1.59729007 +- 0.00069105 Tm 14:10:05 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.59729 0.00069 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.59729 0.00069 1.59729 0.00000 14:10:05 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.59729 0.00069 SL = 1.5972901 +- 0.0006910 Tm^2/m^n 14:10:05 Magnet Strength Measurement Harmonic Number = 1 SL = 1.5972901 +- 0.0006910 Tm^2/m^n 14:10:07 Magnet Current, Imag = 500.1040 A Vtrans = 5.001040 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:10:08 Magnet Current, Imag = 500.1200 A Vtrans = 5.001200 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:10:10 Magnet Current, Imag = 500.1550 A Vtrans = 5.001550 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:10:11 Magnet Current, Imag = 500.1540 A Vtrans = 5.001540 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:10:11 Magnet Current Measurement: Imag = 500.1332 +- 0.0220 A 14:10:12 Magnet current ramping to 450.0000 A... 14:10:35 Magnet Current, Imag = 450.1220 A Vtrans = 4.501220 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:10:36 Magnet Current, Imag = 450.0900 A Vtrans = 4.500900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:10:38 Magnet Current, Imag = 450.0990 A Vtrans = 4.500990 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:10:40 Magnet Current, Imag = 450.1160 A Vtrans = 4.501160 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:10:40 Magnet Current Measurement: Imag = 450.1067 +- 0.0128 A 14:10:40 Magnetic Field Measurement Measuring the magnet strength... 14:10:40 Integrated Voltage Measurement... 14:10:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014204985 Vs 14:11:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014559559 Vs 14:11:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014196712 Vs 14:11:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014570563 Vs 14:11:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014212665 Vs 14:11:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014570307 Vs 14:11:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014207835 Vs 14:12:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014559912 Vs 14:12:09 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014385317 +- 0.000003614 Vs 14:12:09 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.014385317 +- 0.000003614 Vs BL = 1.43853173 +- 0.00036138 Tm 14:12:12 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.43853 0.00036 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.43853 0.00036 1.43853 0.00000 14:12:12 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.43853 0.00036 SL = 1.4385317 +- 0.0003614 Tm^2/m^n 14:12:12 Magnet Strength Measurement Harmonic Number = 1 SL = 1.4385317 +- 0.0003614 Tm^2/m^n 14:12:14 Magnet Current, Imag = 450.1010 A Vtrans = 4.501010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:12:15 Magnet Current, Imag = 450.0740 A Vtrans = 4.500740 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:12:17 Magnet Current, Imag = 450.0880 A Vtrans = 4.500880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:12:19 Magnet Current, Imag = 450.0720 A Vtrans = 4.500720 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:12:19 Magnet Current Measurement: Imag = 450.0837 +- 0.0117 A 14:12:19 Magnet current ramping to 400.0000 A... 14:12:42 Magnet Current, Imag = 400.0920 A Vtrans = 4.000920 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:12:44 Magnet Current, Imag = 400.0960 A Vtrans = 4.000960 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:12:45 Magnet Current, Imag = 400.0730 A Vtrans = 4.000730 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:12:47 Magnet Current, Imag = 400.0460 A Vtrans = 4.000460 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:12:47 Magnet Current Measurement: Imag = 400.0767 +- 0.0198 A 14:12:47 Magnetic Field Measurement Measuring the magnet strength... 14:12:47 Integrated Voltage Measurement... 14:13:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012603735 Vs 14:13:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012970609 Vs 14:13:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012652998 Vs 14:13:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012968790 Vs 14:13:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012609654 Vs 14:13:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012973868 Vs 14:14:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012612561 Vs 14:14:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012989835 Vs 14:14:17 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012797756 +- 0.000009116 Vs 14:14:17 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.012797756 +- 0.000009116 Vs BL = 1.27977564 +- 0.00091161 Tm 14:14:20 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.27978 0.00091 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.27978 0.00091 1.27978 0.00000 14:14:20 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.27978 0.00091 SL = 1.2797756 +- 0.0009116 Tm^2/m^n 14:14:20 Magnet Strength Measurement Harmonic Number = 1 SL = 1.2797756 +- 0.0009116 Tm^2/m^n 14:14:22 Magnet Current, Imag = 400.0710 A Vtrans = 4.000710 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:14:23 Magnet Current, Imag = 400.0580 A Vtrans = 4.000580 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:14:25 Magnet Current, Imag = 400.0330 A Vtrans = 4.000330 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:14:26 Magnet Current, Imag = 400.0620 A Vtrans = 4.000620 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:14:27 Magnet Current Measurement: Imag = 400.0560 +- 0.0141 A 14:14:57 Magnet current ramping to 0.0000 A...