SLAC Magnetic Measurements Date: 05-15-2001 Time: 17:20:18 Project: spear3 Magnet Type: gdipole Magnet Name: 145d-004 Serial Number: Run Number: 10 Measurement Device: single wire Operator: jy Comment: trims BL vs. I Test Currents (A): -12.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 17:20:27 Initial Zero Current Measurement, Imag_zero = 0.0000 A 17:20:28 Magnet current ramping to -12.0000 A... 17:21:48 Magnet Current, Imag = -12.3590 A Vtrans = -0.123590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:21:50 Magnet Current, Imag = -12.3588 A Vtrans = -0.123588 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:21:52 Magnet Current, Imag = -12.3585 A Vtrans = -0.123585 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:21:54 Magnet Current, Imag = -12.3584 A Vtrans = -0.123584 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:21:54 Magnet Current Measurement: Imag = -12.3587 +- 0.0002 A 17:21:54 Magnetic Field Measurement Measuring the magnet strength... 17:21:54 Integrated Voltage Measurement... 17:22:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000553985 Vs 17:22:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001337392 Vs 17:22:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000556463 Vs 17:22:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001336701 Vs 17:22:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000556233 Vs 17:23:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001336810 Vs 17:23:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000555915 Vs 17:23:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001338533 Vs 17:23:23 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000390855 +- 0.000000669 Vs 17:23:23 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000390855 +- 0.000000669 Vs BL = -0.03908551 +- 0.00006687 Tm 17:23:26 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.03909 0.00007 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.03909 0.00007 -0.03909 0.00000 17:23:26 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.03909 0.00007 SL = -0.0390855 +- 0.0000669 Tm^2/m^n 17:23:26 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0390855 +- 0.0000669 Tm^2/m^n 17:23:28 Magnet Current, Imag = -12.3531 A Vtrans = -0.123531 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:23:30 Magnet Current, Imag = -12.3531 A Vtrans = -0.123531 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:23:32 Magnet Current, Imag = -12.3530 A Vtrans = -0.123530 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:23:34 Magnet Current, Imag = -12.3529 A Vtrans = -0.123529 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:23:34 Magnet Current Measurement: Imag = -12.3530 +- 0.0001 A 17:23:34 Magnet current ramping to -10.0000 A... 17:23:55 Magnet Current, Imag = -10.3086 A Vtrans = -0.103085 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:23:57 Magnet Current, Imag = -10.3086 A Vtrans = -0.103086 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:23:59 Magnet Current, Imag = -10.3086 A Vtrans = -0.103086 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:24:01 Magnet Current, Imag = -10.3087 A Vtrans = -0.103087 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:24:01 Magnet Current Measurement: Imag = -10.3086 +- 0.0001 A 17:24:01 Magnetic Field Measurement Measuring the magnet strength... 17:24:01 Integrated Voltage Measurement... 17:24:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000624548 Vs 17:24:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001270839 Vs 17:24:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000623474 Vs 17:24:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001272953 Vs 17:24:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000625235 Vs 17:25:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001273508 Vs 17:25:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000624425 Vs 17:25:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001273001 Vs 17:25:30 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000324078 +- 0.000000582 Vs 17:25:30 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000324078 +- 0.000000582 Vs BL = -0.03240776 +- 0.00005820 Tm 17:25:33 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.03241 0.00006 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.03241 0.00006 -0.03241 0.00000 17:25:33 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.03241 0.00006 SL = -0.0324078 +- 0.0000582 Tm^2/m^n 17:25:33 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0324078 +- 0.0000582 Tm^2/m^n 17:25:35 Magnet Current, Imag = -10.3091 A Vtrans = -0.103091 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:25:37 Magnet Current, Imag = -10.3091 A Vtrans = -0.103091 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:25:39 Magnet Current, Imag = -10.3091 A Vtrans = -0.103091 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:25:41 Magnet Current, Imag = -10.3092 A Vtrans = -0.103092 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:25:41 Magnet Current Measurement: Imag = -10.3091 +- 0.0000 A 17:25:41 Magnet current ramping to -8.0000 A... 17:26:02 Magnet Current, Imag = -8.2808 A Vtrans = -0.082808 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:26:04 Magnet Current, Imag = -8.2810 A Vtrans = -0.082810 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:26:06 Magnet Current, Imag = -8.2810 A Vtrans = -0.082810 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:26:08 Magnet Current, Imag = -8.2810 A Vtrans = -0.082810 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:26:08 Magnet Current Measurement: Imag = -8.2809 +- 0.0001 A 17:26:08 Magnetic Field Measurement Measuring the magnet strength... 17:26:08 Integrated Voltage Measurement... 17:26:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000691487 Vs 17:26:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001205393 Vs 17:26:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000691564 Vs 17:26:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001205403 Vs 17:27:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000691359 Vs 17:27:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001205705 Vs 17:27:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000693895 Vs 17:27:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001208029 Vs 17:27:37 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000257028 +- 0.000000100 Vs 17:27:37 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000257028 +- 0.000000100 Vs BL = -0.02570281 +- 0.00000999 Tm 17:27:40 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02570 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.02570 0.00001 -0.02570 0.00000 17:27:40 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02570 0.00001 SL = -0.0257028 +- 0.0000100 Tm^2/m^n 17:27:40 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0257028 +- 0.0000100 Tm^2/m^n 17:27:42 Magnet Current, Imag = -8.2824 A Vtrans = -0.082824 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:27:44 Magnet Current, Imag = -8.2824 A Vtrans = -0.082824 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:27:46 Magnet Current, Imag = -8.2825 A Vtrans = -0.082825 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:27:48 Magnet Current, Imag = -8.2825 A Vtrans = -0.082825 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:27:48 Magnet Current Measurement: Imag = -8.2824 +- 0.0000 A 17:27:48 Magnet current ramping to -6.0000 A... 17:28:09 Magnet Current, Imag = -6.2526 A Vtrans = -0.062526 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:28:11 Magnet Current, Imag = -6.2527 A Vtrans = -0.062526 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:28:13 Magnet Current, Imag = -6.2527 A Vtrans = -0.062526 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:28:15 Magnet Current, Imag = -6.2528 A Vtrans = -0.062528 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:28:15 Magnet Current Measurement: Imag = -6.2527 +- 0.0000 A 17:28:15 Magnetic Field Measurement Measuring the magnet strength... 17:28:15 Integrated Voltage Measurement... 17:28:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000761520 Vs 17:28:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001140317 Vs 17:28:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000760395 Vs 17:29:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001139272 Vs 17:29:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000762201 Vs 17:29:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001140427 Vs 17:29:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000762017 Vs 17:29:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001140719 Vs 17:29:44 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000189325 +- 0.000000126 Vs 17:29:44 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000189325 +- 0.000000126 Vs BL = -0.01893252 +- 0.00001263 Tm 17:29:47 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01893 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.01893 0.00001 -0.01893 0.00000 17:29:47 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01893 0.00001 SL = -0.0189325 +- 0.0000126 Tm^2/m^n 17:29:47 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0189325 +- 0.0000126 Tm^2/m^n 17:29:49 Magnet Current, Imag = -6.2537 A Vtrans = -0.062537 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:29:51 Magnet Current, Imag = -6.2537 A Vtrans = -0.062537 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:29:53 Magnet Current, Imag = -6.2537 A Vtrans = -0.062537 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:29:55 Magnet Current, Imag = -6.2536 A Vtrans = -0.062536 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:29:55 Magnet Current Measurement: Imag = -6.2537 +- 0.0000 A 17:29:56 Magnet current ramping to -4.0000 A... 17:30:17 Magnet Current, Imag = -4.2236 A Vtrans = -0.042236 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:30:19 Magnet Current, Imag = -4.2236 A Vtrans = -0.042236 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:30:20 Magnet Current, Imag = -4.2237 A Vtrans = -0.042237 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:30:22 Magnet Current, Imag = -4.2236 A Vtrans = -0.042236 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:30:23 Magnet Current Measurement: Imag = -4.2236 +- 0.0000 A 17:30:23 Magnetic Field Measurement Measuring the magnet strength... 17:30:23 Integrated Voltage Measurement... 17:30:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000830664 Vs 17:30:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001073728 Vs 17:30:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000830017 Vs 17:31:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001072642 Vs 17:31:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000830006 Vs 17:31:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001073710 Vs 17:31:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000829804 Vs 17:31:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001072869 Vs 17:31:51 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000121557 +- 0.000000192 Vs 17:31:51 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000121557 +- 0.000000192 Vs BL = -0.01215572 +- 0.00001924 Tm 17:31:54 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01216 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.01216 0.00002 -0.01216 0.00000 17:31:54 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01216 0.00002 SL = -0.0121557 +- 0.0000192 Tm^2/m^n 17:31:54 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0121557 +- 0.0000192 Tm^2/m^n 17:31:56 Magnet Current, Imag = -4.2243 A Vtrans = -0.042243 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:31:58 Magnet Current, Imag = -4.2243 A Vtrans = -0.042243 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:32:00 Magnet Current, Imag = -4.2243 A Vtrans = -0.042243 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:32:02 Magnet Current, Imag = -4.2243 A Vtrans = -0.042243 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:32:02 Magnet Current Measurement: Imag = -4.2243 +- 0.0000 A 17:32:02 Magnet current ramping to -2.0000 A... 17:32:23 Magnet Current, Imag = -2.1941 A Vtrans = -0.021941 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:32:25 Magnet Current, Imag = -2.1941 A Vtrans = -0.021941 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:32:27 Magnet Current, Imag = -2.1940 A Vtrans = -0.021940 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:32:29 Magnet Current, Imag = -2.1941 A Vtrans = -0.021941 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:32:29 Magnet Current Measurement: Imag = -2.1941 +- 0.0000 A 17:32:30 Magnetic Field Measurement Measuring the magnet strength... 17:32:30 Integrated Voltage Measurement... 17:32:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000897071 Vs 17:32:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001005008 Vs 17:33:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000896771 Vs 17:33:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001003165 Vs 17:33:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000896911 Vs 17:33:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001004834 Vs 17:33:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000895411 Vs 17:33:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001003620 Vs 17:33:58 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000053808 +- 0.000000357 Vs 17:33:58 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000053808 +- 0.000000357 Vs BL = -0.00538080 +- 0.00003571 Tm 17:34:01 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00538 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00538 0.00004 -0.00538 0.00000 17:34:01 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00538 0.00004 SL = -0.0053808 +- 0.0000357 Tm^2/m^n 17:34:01 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0053808 +- 0.0000357 Tm^2/m^n 17:34:03 Magnet Current, Imag = -2.1946 A Vtrans = -0.021946 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:34:05 Magnet Current, Imag = -2.1946 A Vtrans = -0.021946 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:34:07 Magnet Current, Imag = -2.1946 A Vtrans = -0.021946 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:34:09 Magnet Current, Imag = -2.1946 A Vtrans = -0.021946 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:34:09 Magnet Current Measurement: Imag = -2.1946 +- 0.0000 A 17:34:09 Magnet current ramping to 0.0000 A... 17:34:31 Magnet Current, Imag = -0.1629 A Vtrans = -0.001629 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:34:33 Magnet Current, Imag = -0.1630 A Vtrans = -0.001630 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:34:35 Magnet Current, Imag = -0.1630 A Vtrans = -0.001630 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:34:37 Magnet Current, Imag = -0.1630 A Vtrans = -0.001630 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:34:37 Magnet Current Measurement: Imag = -0.1630 +- 0.0001 A 17:34:37 Magnetic Field Measurement Measuring the magnet strength... 17:34:37 Integrated Voltage Measurement... 17:34:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000963720 Vs 17:35:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000936781 Vs 17:35:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000965352 Vs 17:35:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000936698 Vs 17:35:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000965386 Vs 17:35:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000936431 Vs 17:35:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000963937 Vs 17:36:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000935787 Vs 17:36:05 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000014087 +- 0.000000385 Vs 17:36:05 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000014087 +- 0.000000385 Vs BL = 0.00140872 +- 0.00003847 Tm 17:36:08 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00141 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00141 0.00004 0.00141 0.00000 17:36:08 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00141 0.00004 SL = 0.0014087 +- 0.0000385 Tm^2/m^n 17:36:08 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0014087 +- 0.0000385 Tm^2/m^n 17:36:10 Magnet Current, Imag = -0.1632 A Vtrans = -0.001632 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:36:12 Magnet Current, Imag = -0.1632 A Vtrans = -0.001632 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:36:14 Magnet Current, Imag = -0.1632 A Vtrans = -0.001632 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:36:16 Magnet Current, Imag = -0.1632 A Vtrans = -0.001632 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:36:16 Magnet Current Measurement: Imag = -0.1632 +- 0.0000 A 17:36:17 Magnet current ramping to 2.0000 A... 17:36:38 Magnet Current, Imag = 1.8682 A Vtrans = 0.018682 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:36:40 Magnet Current, Imag = 1.8682 A Vtrans = 0.018682 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:36:42 Magnet Current, Imag = 1.8682 A Vtrans = 0.018682 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:36:43 Magnet Current, Imag = 1.8682 A Vtrans = 0.018682 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:36:44 Magnet Current Measurement: Imag = 1.8682 +- 0.0000 A 17:36:44 Magnetic Field Measurement Measuring the magnet strength... 17:36:44 Integrated Voltage Measurement... 17:36:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001031538 Vs 17:37:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000867102 Vs 17:37:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001032381 Vs 17:37:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000868585 Vs 17:37:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001032462 Vs 17:37:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000867581 Vs 17:38:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001031159 Vs 17:38:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000868089 Vs 17:38:13 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000082023 +- 0.000000341 Vs 17:38:13 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000082023 +- 0.000000341 Vs BL = 0.00820228 +- 0.00003413 Tm 17:38:16 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00820 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00820 0.00003 0.00820 0.00000 17:38:16 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00820 0.00003 SL = 0.0082023 +- 0.0000341 Tm^2/m^n 17:38:16 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0082023 +- 0.0000341 Tm^2/m^n 17:38:18 Magnet Current, Imag = 1.8681 A Vtrans = 0.018681 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:38:20 Magnet Current, Imag = 1.8681 A Vtrans = 0.018681 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:38:22 Magnet Current, Imag = 1.8680 A Vtrans = 0.018680 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:38:24 Magnet Current, Imag = 1.8681 A Vtrans = 0.018681 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:38:24 Magnet Current Measurement: Imag = 1.8681 +- 0.0000 A 17:38:24 Magnet current ramping to 4.0000 A... 17:38:45 Magnet Current, Imag = 3.8988 A Vtrans = 0.038988 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:38:47 Magnet Current, Imag = 3.8987 A Vtrans = 0.038987 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:38:49 Magnet Current, Imag = 3.8987 A Vtrans = 0.038987 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:38:51 Magnet Current, Imag = 3.8986 A Vtrans = 0.038986 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:38:51 Magnet Current Measurement: Imag = 3.8987 +- 0.0001 A 17:38:51 Magnetic Field Measurement Measuring the magnet strength... 17:38:51 Integrated Voltage Measurement... 17:39:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001098149 Vs 17:39:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000798951 Vs 17:39:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001098577 Vs 17:39:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000798789 Vs 17:39:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001099408 Vs 17:39:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000798357 Vs 17:40:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001099467 Vs 17:40:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000798962 Vs 17:40:20 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000150068 +- 0.000000351 Vs 17:40:20 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000150068 +- 0.000000351 Vs BL = 0.01500677 +- 0.00003514 Tm 17:40:23 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.01501 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.01501 0.00004 0.01501 0.00000 17:40:23 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.01501 0.00004 SL = 0.0150068 +- 0.0000351 Tm^2/m^n 17:40:23 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0150068 +- 0.0000351 Tm^2/m^n 17:40:25 Magnet Current, Imag = 3.8982 A Vtrans = 0.038982 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:40:27 Magnet Current, Imag = 3.8983 A Vtrans = 0.038983 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:40:29 Magnet Current, Imag = 3.8982 A Vtrans = 0.038982 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:40:31 Magnet Current, Imag = 3.8982 A Vtrans = 0.038982 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:40:31 Magnet Current Measurement: Imag = 3.8982 +- 0.0000 A 17:40:31 Magnet current ramping to 6.0000 A... 17:40:52 Magnet Current, Imag = 5.9287 A Vtrans = 0.059287 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:40:54 Magnet Current, Imag = 5.9286 A Vtrans = 0.059286 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:40:56 Magnet Current, Imag = 5.9285 A Vtrans = 0.059285 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:40:58 Magnet Current, Imag = 5.9284 A Vtrans = 0.059284 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:40:58 Magnet Current Measurement: Imag = 5.9285 +- 0.0001 A 17:40:58 Magnetic Field Measurement Measuring the magnet strength... 17:40:58 Integrated Voltage Measurement... 17:41:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001167233 Vs 17:41:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000730429 Vs 17:41:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001166771 Vs 17:41:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000730332 Vs 17:41:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001166359 Vs 17:42:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000729613 Vs 17:42:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001166153 Vs 17:42:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000729567 Vs 17:42:28 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000218322 +- 0.000000071 Vs 17:42:28 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000218322 +- 0.000000071 Vs BL = 0.02183218 +- 0.00000712 Tm 17:42:31 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.02183 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.02183 0.00001 0.02183 0.00000 17:42:31 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.02183 0.00001 SL = 0.0218322 +- 0.0000071 Tm^2/m^n 17:42:31 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0218322 +- 0.0000071 Tm^2/m^n 17:42:33 Magnet Current, Imag = 5.9275 A Vtrans = 0.059275 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:42:35 Magnet Current, Imag = 5.9275 A Vtrans = 0.059275 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:42:37 Magnet Current, Imag = 5.9275 A Vtrans = 0.059275 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:42:39 Magnet Current, Imag = 5.9275 A Vtrans = 0.059275 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:42:39 Magnet Current Measurement: Imag = 5.9275 +- 0.0000 A 17:42:39 Magnet current ramping to 8.0000 A... 17:43:00 Magnet Current, Imag = 7.9572 A Vtrans = 0.079572 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:43:02 Magnet Current, Imag = 7.9571 A Vtrans = 0.079571 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:43:04 Magnet Current, Imag = 7.9569 A Vtrans = 0.079569 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:43:06 Magnet Current, Imag = 7.9568 A Vtrans = 0.079568 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:43:06 Magnet Current Measurement: Imag = 7.9570 +- 0.0001 A 17:43:06 Magnetic Field Measurement Measuring the magnet strength... 17:43:06 Integrated Voltage Measurement... 17:43:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001232931 Vs 17:43:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000659792 Vs 17:43:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001233680 Vs 17:43:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000659607 Vs 17:44:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001232703 Vs 17:44:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000659193 Vs 17:44:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001233403 Vs 17:44:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000660206 Vs 17:44:34 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000286740 +- 0.000000185 Vs 17:44:34 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000286740 +- 0.000000185 Vs BL = 0.02867397 +- 0.00001852 Tm 17:44:38 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.02867 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.02867 0.00002 0.02867 0.00000 17:44:38 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.02867 0.00002 SL = 0.0286740 +- 0.0000185 Tm^2/m^n 17:44:38 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0286740 +- 0.0000185 Tm^2/m^n 17:44:40 Magnet Current, Imag = 7.9553 A Vtrans = 0.079553 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:44:42 Magnet Current, Imag = 7.9553 A Vtrans = 0.079553 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:44:44 Magnet Current, Imag = 7.9553 A Vtrans = 0.079553 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:44:45 Magnet Current, Imag = 7.9552 A Vtrans = 0.079552 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:44:45 Magnet Current Measurement: Imag = 7.9553 +- 0.0000 A 17:44:46 Magnet current ramping to 10.0000 A... 17:45:07 Magnet Current, Imag = 9.9831 A Vtrans = 0.099831 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:45:09 Magnet Current, Imag = 9.9830 A Vtrans = 0.099830 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:45:11 Magnet Current, Imag = 9.9828 A Vtrans = 0.099828 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:45:12 Magnet Current, Imag = 9.9826 A Vtrans = 0.099826 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:45:13 Magnet Current Measurement: Imag = 9.9829 +- 0.0002 A 17:45:13 Magnetic Field Measurement Measuring the magnet strength... 17:45:13 Integrated Voltage Measurement... 17:45:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001300661 Vs 17:45:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000591189 Vs 17:45:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001301191 Vs 17:45:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000591337 Vs 17:46:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001301247 Vs 17:46:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000591210 Vs 17:46:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001300865 Vs 17:46:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000590860 Vs 17:46:41 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000354921 +- 0.000000112 Vs 17:46:41 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000354921 +- 0.000000112 Vs BL = 0.03549210 +- 0.00001122 Tm 17:46:45 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.03549 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.03549 0.00001 0.03549 0.00000 17:46:45 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.03549 0.00001 SL = 0.0354921 +- 0.0000112 Tm^2/m^n 17:46:45 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0354921 +- 0.0000112 Tm^2/m^n 17:46:47 Magnet Current, Imag = 9.9804 A Vtrans = 0.099804 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:46:49 Magnet Current, Imag = 9.9803 A Vtrans = 0.099803 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:46:51 Magnet Current, Imag = 9.9804 A Vtrans = 0.099804 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:46:52 Magnet Current, Imag = 9.9803 A Vtrans = 0.099803 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:46:53 Magnet Current Measurement: Imag = 9.9804 +- 0.0000 A 17:46:53 Magnet current ramping to 12.0000 A... 17:47:14 Magnet Current, Imag = 12.0073 A Vtrans = 0.120073 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:47:16 Magnet Current, Imag = 12.0071 A Vtrans = 0.120071 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:47:18 Magnet Current, Imag = 12.0068 A Vtrans = 0.120068 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:47:19 Magnet Current, Imag = 12.0067 A Vtrans = 0.120067 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:47:19 Magnet Current Measurement: Imag = 12.0070 +- 0.0002 A 17:47:20 Magnetic Field Measurement Measuring the magnet strength... 17:47:20 Integrated Voltage Measurement... 17:47:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001369277 Vs 17:47:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000522491 Vs 17:47:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001369372 Vs 17:48:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000521623 Vs 17:48:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001369035 Vs 17:48:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000522403 Vs 17:48:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001368914 Vs 17:48:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000523261 Vs 17:48:48 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000423352 +- 0.000000372 Vs 17:48:48 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000423352 +- 0.000000372 Vs BL = 0.04233524 +- 0.00003715 Tm 17:48:52 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.04234 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.04234 0.00004 0.04234 0.00000 17:48:52 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.04234 0.00004 SL = 0.0423352 +- 0.0000372 Tm^2/m^n 17:48:52 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0423352 +- 0.0000372 Tm^2/m^n 17:48:54 Magnet Current, Imag = 12.0034 A Vtrans = 0.120034 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:48:56 Magnet Current, Imag = 12.0033 A Vtrans = 0.120034 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:48:58 Magnet Current, Imag = 12.0033 A Vtrans = 0.120034 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:49:00 Magnet Current, Imag = 12.0033 A Vtrans = 0.120033 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:49:00 Magnet Current Measurement: Imag = 12.0034 +- 0.0000 A 17:49:01 Magnet current ramping to 0.0000 A...