SLAC Magnetic Measurements Date: 02-14-2002 Time: 15:27:45 Project: spear3 Magnet Type: gdipole Magnet Name: 109D-035 Serial Number: Run Number: 11 Measurement Device: stretched wire Operator: jy Comment: bl v. i, trims Test Currents (A): -12.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 15:27:52 Initial Zero Current Measurement, Imag_zero = 0.0000 A 15:28:22 Magnet current ramping to -12.0000 A... 15:29:14 Magnet Current, Imag = -12.0917 A Vtrans = -0.120917 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:29:16 Magnet Current, Imag = -12.0914 A Vtrans = -0.120914 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:29:18 Magnet Current, Imag = -12.0911 A Vtrans = -0.120911 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:29:20 Magnet Current, Imag = -12.0908 A Vtrans = -0.120908 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:29:20 Magnet Current Measurement: Imag = -12.0912 +- 0.0003 A 15:29:20 Magnetic Field Measurement Measuring the magnet strength... 15:29:20 Integrated Voltage Measurement... 15:29:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000468143 Vs 15:29:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000107773 Vs 15:29:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000471427 Vs 15:30:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000108621 Vs 15:30:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000469197 Vs 15:30:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000108275 Vs 15:30:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000469600 Vs 15:30:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000108040 Vs 15:30:48 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000288885 +- 0.000000739 Vs 15:30:48 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000288885 +- 0.000000739 Vs BL = -0.02888845 +- 0.00007386 Tm 15:30:51 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02889 0.00007 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.02889 0.00007 -0.02889 0.00000 15:30:51 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02889 0.00007 SL = -0.0288884 +- 0.0000739 Tm^2/m^n 15:30:51 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0288884 +- 0.0000739 Tm^2/m^n 15:30:53 Magnet Current, Imag = -12.0817 A Vtrans = -0.120817 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:30:55 Magnet Current, Imag = -12.0817 A Vtrans = -0.120817 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:30:57 Magnet Current, Imag = -12.0816 A Vtrans = -0.120816 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:30:59 Magnet Current, Imag = -12.0815 A Vtrans = -0.120815 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:30:59 Magnet Current Measurement: Imag = -12.0816 +- 0.0001 A 15:30:59 Magnet current ramping to -10.0000 A... 15:31:15 Magnet Current, Imag = -10.0349 A Vtrans = -0.100349 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:31:17 Magnet Current, Imag = -10.0349 A Vtrans = -0.100349 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:31:19 Magnet Current, Imag = -10.0348 A Vtrans = -0.100348 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:31:20 Magnet Current, Imag = -10.0348 A Vtrans = -0.100348 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:31:20 Magnet Current Measurement: Imag = -10.0349 +- 0.0000 A 15:31:21 Magnetic Field Measurement Measuring the magnet strength... 15:31:21 Integrated Voltage Measurement... 15:31:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000419819 Vs 15:31:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000056633 Vs 15:31:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000418881 Vs 15:32:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000056221 Vs 15:32:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000419625 Vs 15:32:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000056445 Vs 15:32:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000419365 Vs 15:32:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000056063 Vs 15:32:48 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000237881 +- 0.000000264 Vs 15:32:48 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000237881 +- 0.000000264 Vs BL = -0.02378814 +- 0.00002643 Tm 15:32:51 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02379 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.02379 0.00003 -0.02379 0.00000 15:32:51 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02379 0.00003 SL = -0.0237881 +- 0.0000264 Tm^2/m^n 15:32:51 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0237881 +- 0.0000264 Tm^2/m^n 15:32:53 Magnet Current, Imag = -10.0347 A Vtrans = -0.100347 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:32:55 Magnet Current, Imag = -10.0347 A Vtrans = -0.100347 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:32:57 Magnet Current, Imag = -10.0347 A Vtrans = -0.100347 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:32:59 Magnet Current, Imag = -10.0346 A Vtrans = -0.100346 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:32:59 Magnet Current Measurement: Imag = -10.0347 +- 0.0000 A 15:32:59 Magnet current ramping to -8.0000 A... 15:33:15 Magnet Current, Imag = -8.0051 A Vtrans = -0.080051 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:33:17 Magnet Current, Imag = -8.0051 A Vtrans = -0.080051 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:33:19 Magnet Current, Imag = -8.0051 A Vtrans = -0.080051 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:33:21 Magnet Current, Imag = -8.0052 A Vtrans = -0.080052 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:33:21 Magnet Current Measurement: Imag = -8.0051 +- 0.0000 A 15:33:21 Magnetic Field Measurement Measuring the magnet strength... 15:33:21 Integrated Voltage Measurement... 15:33:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000367937 Vs 15:33:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000003892 Vs 15:33:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000368088 Vs 15:34:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000004113 Vs 15:34:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000368531 Vs 15:34:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000005399 Vs 15:34:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000368119 Vs 15:34:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000004058 Vs 15:34:49 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000186267 +- 0.000000410 Vs 15:34:49 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000186267 +- 0.000000410 Vs BL = -0.01862672 +- 0.00004095 Tm 15:34:52 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01863 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.01863 0.00004 -0.01863 0.00000 15:34:52 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01863 0.00004 SL = -0.0186267 +- 0.0000410 Tm^2/m^n 15:34:52 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0186267 +- 0.0000410 Tm^2/m^n 15:34:54 Magnet Current, Imag = -8.0064 A Vtrans = -0.080064 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:34:56 Magnet Current, Imag = -8.0064 A Vtrans = -0.080064 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:34:58 Magnet Current, Imag = -8.0064 A Vtrans = -0.080064 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:35:00 Magnet Current, Imag = -8.0064 A Vtrans = -0.080064 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:35:00 Magnet Current Measurement: Imag = -8.0064 +- 0.0000 A 15:35:00 Magnet current ramping to -6.0000 A... 15:35:16 Magnet Current, Imag = -5.9757 A Vtrans = -0.059757 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:35:18 Magnet Current, Imag = -5.9757 A Vtrans = -0.059757 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:35:20 Magnet Current, Imag = -5.9757 A Vtrans = -0.059757 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:35:21 Magnet Current, Imag = -5.9757 A Vtrans = -0.059757 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:35:21 Magnet Current Measurement: Imag = -5.9757 +- 0.0000 A 15:35:21 Magnetic Field Measurement Measuring the magnet strength... 15:35:22 Integrated Voltage Measurement... 15:35:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000318239 Vs 15:35:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000046921 Vs 15:35:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000317578 Vs 15:36:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000047180 Vs 15:36:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000317673 Vs 15:36:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000046685 Vs 15:36:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000317449 Vs 15:36:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000048158 Vs 15:36:50 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000135249 +- 0.000000386 Vs 15:36:50 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000135249 +- 0.000000386 Vs BL = -0.01352492 +- 0.00003856 Tm 15:36:53 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01352 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.01352 0.00004 -0.01352 0.00000 15:36:53 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01352 0.00004 SL = -0.0135249 +- 0.0000386 Tm^2/m^n 15:36:53 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0135249 +- 0.0000386 Tm^2/m^n 15:36:55 Magnet Current, Imag = -5.9768 A Vtrans = -0.059768 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:36:57 Magnet Current, Imag = -5.9768 A Vtrans = -0.059768 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:36:59 Magnet Current, Imag = -5.9768 A Vtrans = -0.059768 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:37:01 Magnet Current, Imag = -5.9768 A Vtrans = -0.059768 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:37:01 Magnet Current Measurement: Imag = -5.9768 +- 0.0000 A 15:37:01 Magnet current ramping to -4.0000 A... 15:37:17 Magnet Current, Imag = -3.9460 A Vtrans = -0.039460 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:37:19 Magnet Current, Imag = -3.9460 A Vtrans = -0.039460 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:37:21 Magnet Current, Imag = -3.9460 A Vtrans = -0.039460 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:37:23 Magnet Current, Imag = -3.9461 A Vtrans = -0.039461 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:37:23 Magnet Current Measurement: Imag = -3.9460 +- 0.0000 A 15:37:23 Magnetic Field Measurement Measuring the magnet strength... 15:37:23 Integrated Voltage Measurement... 15:37:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000270521 Vs 15:37:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000101612 Vs 15:37:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000269766 Vs 15:38:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000102197 Vs 15:38:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000268819 Vs 15:38:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000102743 Vs 15:38:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000269873 Vs 15:38:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000102040 Vs 15:38:52 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000083798 +- 0.000000506 Vs 15:38:53 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000083798 +- 0.000000506 Vs BL = -0.00837983 +- 0.00005057 Tm 15:38:56 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00838 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00838 0.00005 -0.00838 0.00000 15:38:56 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00838 0.00005 SL = -0.0083798 +- 0.0000506 Tm^2/m^n 15:38:56 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0083798 +- 0.0000506 Tm^2/m^n 15:38:58 Magnet Current, Imag = -3.9466 A Vtrans = -0.039466 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:39:00 Magnet Current, Imag = -3.9466 A Vtrans = -0.039466 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:39:02 Magnet Current, Imag = -3.9466 A Vtrans = -0.039466 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:39:04 Magnet Current, Imag = -3.9466 A Vtrans = -0.039466 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:39:04 Magnet Current Measurement: Imag = -3.9466 +- 0.0000 A 15:39:04 Magnet current ramping to -2.0000 A... 15:39:20 Magnet Current, Imag = -1.9159 A Vtrans = -0.019159 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:39:22 Magnet Current, Imag = -1.9159 A Vtrans = -0.019159 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:39:24 Magnet Current, Imag = -1.9160 A Vtrans = -0.019160 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:39:26 Magnet Current, Imag = -1.9159 A Vtrans = -0.019159 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:39:26 Magnet Current Measurement: Imag = -1.9159 +- 0.0000 A 15:39:26 Magnetic Field Measurement Measuring the magnet strength... 15:39:26 Integrated Voltage Measurement... 15:39:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000219066 Vs 15:39:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000154373 Vs 15:40:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000219045 Vs 15:40:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000153990 Vs 15:40:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000218651 Vs 15:40:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000154629 Vs 15:40:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000218852 Vs 15:40:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000154641 Vs 15:40:55 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000032248 +- 0.000000203 Vs 15:40:55 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = -0.000032248 +- 0.000000203 Vs BL = -0.00322476 +- 0.00002027 Tm 15:40:58 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00322 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 -0.00322 0.00002 -0.00322 0.00000 15:40:58 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00322 0.00002 SL = -0.0032248 +- 0.0000203 Tm^2/m^n 15:40:58 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0032248 +- 0.0000203 Tm^2/m^n 15:41:00 Magnet Current, Imag = -1.9163 A Vtrans = -0.019163 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:41:02 Magnet Current, Imag = -1.9164 A Vtrans = -0.019164 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:41:05 Magnet Current, Imag = -1.9163 A Vtrans = -0.019163 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:41:07 Magnet Current, Imag = -1.9163 A Vtrans = -0.019163 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:41:07 Magnet Current Measurement: Imag = -1.9163 +- 0.0000 A 15:41:07 Magnet current ramping to 0.0000 A... 15:41:23 Magnet Current, Imag = 0.1162 A Vtrans = 0.001162 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:41:25 Magnet Current, Imag = 0.1162 A Vtrans = 0.001162 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:41:26 Magnet Current, Imag = 0.1161 A Vtrans = 0.001161 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:41:28 Magnet Current, Imag = 0.1161 A Vtrans = 0.001161 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:41:28 Magnet Current Measurement: Imag = 0.1162 +- 0.0000 A 15:41:28 Magnetic Field Measurement Measuring the magnet strength... 15:41:28 Integrated Voltage Measurement... 15:41:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000168688 Vs 15:41:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000207063 Vs 15:42:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000167324 Vs 15:42:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000206511 Vs 15:42:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000167673 Vs 15:42:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000205421 Vs 15:42:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000166571 Vs 15:42:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000205924 Vs 15:42:58 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000019333 +- 0.000000323 Vs 15:42:58 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000019333 +- 0.000000323 Vs BL = 0.00193330 +- 0.00003230 Tm 15:43:01 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00193 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00193 0.00003 0.00193 0.00000 15:43:01 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00193 0.00003 SL = 0.0019333 +- 0.0000323 Tm^2/m^n 15:43:01 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0019333 +- 0.0000323 Tm^2/m^n 15:43:03 Magnet Current, Imag = 0.1159 A Vtrans = 0.001159 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:43:05 Magnet Current, Imag = 0.1159 A Vtrans = 0.001159 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:43:07 Magnet Current, Imag = 0.1159 A Vtrans = 0.001159 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:43:09 Magnet Current, Imag = 0.1159 A Vtrans = 0.001159 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:43:09 Magnet Current Measurement: Imag = 0.1159 +- 0.0000 A 15:43:09 Magnet current ramping to 2.0000 A... 15:43:25 Magnet Current, Imag = 2.1481 A Vtrans = 0.021481 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:43:27 Magnet Current, Imag = 2.1481 A Vtrans = 0.021481 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:43:29 Magnet Current, Imag = 2.1480 A Vtrans = 0.021480 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:43:31 Magnet Current, Imag = 2.1480 A Vtrans = 0.021480 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:43:31 Magnet Current Measurement: Imag = 2.1481 +- 0.0001 A 15:43:31 Magnetic Field Measurement Measuring the magnet strength... 15:43:31 Integrated Voltage Measurement... 15:43:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000116905 Vs 15:43:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000257847 Vs 15:44:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000116082 Vs 15:44:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000259863 Vs 15:44:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000116973 Vs 15:44:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000260095 Vs 15:44:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000115735 Vs 15:44:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000258216 Vs 15:44:58 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000071291 +- 0.000000526 Vs 15:44:58 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000071291 +- 0.000000526 Vs BL = 0.00712909 +- 0.00005262 Tm 15:45:01 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00713 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.00713 0.00005 0.00713 0.00000 15:45:01 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00713 0.00005 SL = 0.0071291 +- 0.0000526 Tm^2/m^n 15:45:01 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0071291 +- 0.0000526 Tm^2/m^n 15:45:03 Magnet Current, Imag = 2.1478 A Vtrans = 0.021478 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:45:05 Magnet Current, Imag = 2.1478 A Vtrans = 0.021478 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:45:07 Magnet Current, Imag = 2.1478 A Vtrans = 0.021478 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:45:09 Magnet Current, Imag = 2.1478 A Vtrans = 0.021478 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:45:09 Magnet Current Measurement: Imag = 2.1478 +- 0.0000 A 15:45:09 Magnet current ramping to 4.0000 A... 15:45:25 Magnet Current, Imag = 4.1793 A Vtrans = 0.041793 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:45:27 Magnet Current, Imag = 4.1792 A Vtrans = 0.041792 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:45:29 Magnet Current, Imag = 4.1791 A Vtrans = 0.041792 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:45:31 Magnet Current, Imag = 4.1791 A Vtrans = 0.041791 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:45:31 Magnet Current Measurement: Imag = 4.1792 +- 0.0001 A 15:45:31 Magnetic Field Measurement Measuring the magnet strength... 15:45:31 Integrated Voltage Measurement... 15:45:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000064474 Vs 15:45:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000310961 Vs 15:46:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000064463 Vs 15:46:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000310085 Vs 15:46:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000063851 Vs 15:46:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000311097 Vs 15:46:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000064052 Vs 15:46:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000309226 Vs 15:46:59 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000123066 +- 0.000000399 Vs 15:46:59 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000123066 +- 0.000000399 Vs BL = 0.01230662 +- 0.00003990 Tm 15:47:02 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.01231 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.01231 0.00004 0.01231 0.00000 15:47:02 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.01231 0.00004 SL = 0.0123066 +- 0.0000399 Tm^2/m^n 15:47:02 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0123066 +- 0.0000399 Tm^2/m^n 15:47:04 Magnet Current, Imag = 4.1785 A Vtrans = 0.041785 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:06 Magnet Current, Imag = 4.1786 A Vtrans = 0.041786 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:08 Magnet Current, Imag = 4.1786 A Vtrans = 0.041786 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:10 Magnet Current, Imag = 4.1786 A Vtrans = 0.041786 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:10 Magnet Current Measurement: Imag = 4.1786 +- 0.0000 A 15:47:10 Magnet current ramping to 6.0000 A... 15:47:26 Magnet Current, Imag = 6.2099 A Vtrans = 0.062099 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:28 Magnet Current, Imag = 6.2098 A Vtrans = 0.062098 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:29 Magnet Current, Imag = 6.2096 A Vtrans = 0.062096 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:31 Magnet Current, Imag = 6.2096 A Vtrans = 0.062096 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:47:31 Magnet Current Measurement: Imag = 6.2097 +- 0.0001 A 15:47:31 Magnetic Field Measurement Measuring the magnet strength... 15:47:31 Integrated Voltage Measurement... 15:47:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000010150 Vs 15:47:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000360304 Vs 15:48:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000009093 Vs 15:48:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000359858 Vs 15:48:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000008831 Vs 15:48:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000359657 Vs 15:48:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000010662 Vs 15:49:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000360250 Vs 15:49:01 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000175167 +- 0.000000252 Vs 15:49:01 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000175167 +- 0.000000252 Vs BL = 0.01751667 +- 0.00002521 Tm 15:49:04 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.01752 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.01752 0.00003 0.01752 0.00000 15:49:04 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.01752 0.00003 SL = 0.0175167 +- 0.0000252 Tm^2/m^n 15:49:04 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0175167 +- 0.0000252 Tm^2/m^n 15:49:06 Magnet Current, Imag = 6.2083 A Vtrans = 0.062083 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:49:08 Magnet Current, Imag = 6.2084 A Vtrans = 0.062084 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:49:10 Magnet Current, Imag = 6.2083 A Vtrans = 0.062083 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:49:12 Magnet Current, Imag = 6.2083 A Vtrans = 0.062083 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:49:12 Magnet Current Measurement: Imag = 6.2083 +- 0.0000 A 15:49:12 Magnet current ramping to 8.0000 A... 15:49:28 Magnet Current, Imag = 8.2390 A Vtrans = 0.082390 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:49:30 Magnet Current, Imag = 8.2387 A Vtrans = 0.082387 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:49:31 Magnet Current, Imag = 8.2386 A Vtrans = 0.082386 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:49:33 Magnet Current, Imag = 8.2385 A Vtrans = 0.082385 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:49:33 Magnet Current Measurement: Imag = 8.2387 +- 0.0002 A 15:49:33 Magnetic Field Measurement Measuring the magnet strength... 15:49:33 Integrated Voltage Measurement... 15:49:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000043177 Vs 15:49:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000411477 Vs 15:50:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000042911 Vs 15:50:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000411365 Vs 15:50:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000042555 Vs 15:50:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000410749 Vs 15:50:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000042938 Vs 15:51:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000410790 Vs 15:51:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000226995 +- 0.000000258 Vs 15:51:02 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000226995 +- 0.000000258 Vs BL = 0.02269952 +- 0.00002577 Tm 15:51:05 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.02270 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.02270 0.00003 0.02270 0.00000 15:51:05 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.02270 0.00003 SL = 0.0226995 +- 0.0000258 Tm^2/m^n 15:51:05 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0226995 +- 0.0000258 Tm^2/m^n 15:51:07 Magnet Current, Imag = 8.2364 A Vtrans = 0.082364 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:51:09 Magnet Current, Imag = 8.2365 A Vtrans = 0.082365 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:51:11 Magnet Current, Imag = 8.2364 A Vtrans = 0.082364 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:51:13 Magnet Current, Imag = 8.2364 A Vtrans = 0.082364 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:51:13 Magnet Current Measurement: Imag = 8.2364 +- 0.0001 A 15:51:13 Magnet current ramping to 10.0000 A... 15:51:29 Magnet Current, Imag = 10.2653 A Vtrans = 0.102653 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:51:31 Magnet Current, Imag = 10.2651 A Vtrans = 0.102651 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:51:32 Magnet Current, Imag = 10.2649 A Vtrans = 0.102649 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:51:34 Magnet Current, Imag = 10.2646 A Vtrans = 0.102646 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:51:34 Magnet Current Measurement: Imag = 10.2650 +- 0.0003 A 15:51:34 Magnetic Field Measurement Measuring the magnet strength... 15:51:34 Integrated Voltage Measurement... 15:51:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000096184 Vs 15:51:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000462539 Vs 15:52:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000096976 Vs 15:52:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000462297 Vs 15:52:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000096487 Vs 15:52:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000462644 Vs 15:52:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000096286 Vs 15:53:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000461532 Vs 15:53:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000279368 +- 0.000000284 Vs 15:53:02 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000279368 +- 0.000000284 Vs BL = 0.02793681 +- 0.00002836 Tm 15:53:05 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.02794 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.02794 0.00003 0.02794 0.00000 15:53:05 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.02794 0.00003 SL = 0.0279368 +- 0.0000284 Tm^2/m^n 15:53:05 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0279368 +- 0.0000284 Tm^2/m^n 15:53:07 Magnet Current, Imag = 10.2617 A Vtrans = 0.102617 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:53:09 Magnet Current, Imag = 10.2617 A Vtrans = 0.102618 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:53:11 Magnet Current, Imag = 10.2617 A Vtrans = 0.102617 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:53:13 Magnet Current, Imag = 10.2617 A Vtrans = 0.102617 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:53:13 Magnet Current Measurement: Imag = 10.2617 +- 0.0000 A 15:53:13 Magnet current ramping to 12.0000 A... 15:53:29 Magnet Current, Imag = 12.2901 A Vtrans = 0.122901 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:53:31 Magnet Current, Imag = 12.2898 A Vtrans = 0.122898 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:53:33 Magnet Current, Imag = 12.2894 A Vtrans = 0.122894 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:53:35 Magnet Current, Imag = 12.2892 A Vtrans = 0.122892 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:53:35 Magnet Current Measurement: Imag = 12.2896 +- 0.0003 A 15:53:35 Magnetic Field Measurement Measuring the magnet strength... 15:53:35 Integrated Voltage Measurement... 15:53:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000149375 Vs 15:53:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000511732 Vs 15:54:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000149221 Vs 15:54:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000512633 Vs 15:54:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000149162 Vs 15:54:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000512037 Vs 15:54:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000149992 Vs 15:55:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000511649 Vs 15:55:03 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000330725 +- 0.000000154 Vs 15:55:03 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000330725 +- 0.000000154 Vs BL = 0.03307252 +- 0.00001541 Tm 15:55:06 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.03307 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.03307 0.00002 0.03307 0.00000 15:55:06 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.03307 0.00002 SL = 0.0330725 +- 0.0000154 Tm^2/m^n 15:55:06 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0330725 +- 0.0000154 Tm^2/m^n 15:55:08 Magnet Current, Imag = 12.2848 A Vtrans = 0.122848 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:55:10 Magnet Current, Imag = 12.2848 A Vtrans = 0.122848 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:55:12 Magnet Current, Imag = 12.2848 A Vtrans = 0.122848 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:55:14 Magnet Current, Imag = 12.2847 A Vtrans = 0.122847 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:55:14 Magnet Current Measurement: Imag = 12.2848 +- 0.0000 A 15:55:44 Magnet current ramping to 0.0000 A...