SLAC Magnetic Measurements Date: 04-24-2002 Time: 13:54:56 Project: spear3 Magnet Type: gdipole Magnet Name: 109D-034 Serial Number: Run Number: 10 Measurement Device: stretched wire Operator: sa Comment: BL vs. I, Mains Standardization: 1 cycles from 0.0 A to 770.0 A to 0.0 A Test Currents (A): 50.0 100.0 150.0 200.0 250.0 300.0 350.0 400.0 450.0 500.0 525.0 550.0 575.0 600.0 625.0 650.0 675.0 700.0 650.0 600.0 550.0 500.0 450.0 400.0 13:55:21 Initial Zero Current Measurement, Imag_zero = 0.0000 A 13:55:21 Magnet current ramping to 15.0000 A... 13:55:53 Magnet current ramping to 770.0000 A... 14:00:06 Magnet current ramping to 0.0000 A... 14:04:52 Magnet current ramping to 50.0000 A... 14:05:15 Magnet Current, Imag = 61.5429 A Vtrans = 0.615429 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:05:17 Magnet Current, Imag = 45.8654 A Vtrans = 0.458654 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:05:18 Magnet Current, Imag = 47.6741 A Vtrans = 0.476741 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:05:19 Magnet Current, Imag = 50.9399 A Vtrans = 0.509399 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:05:19 Magnet Current Measurement: Imag = 51.5056 +- 6.0737 A 14:05:19 Magnetic Field Measurement Measuring the magnet strength... 14:05:20 Integrated Voltage Measurement... 14:05:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001143857 Vs 14:05:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001326393 Vs 14:05:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001093983 Vs 14:06:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001333501 Vs 14:06:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001098762 Vs 14:06:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001325539 Vs 14:06:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001102691 Vs 14:06:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.001339729 Vs 14:06:46 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.001220557 +- 0.000009080 Vs 14:06:46 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.001220557 +- 0.000009080 Vs BL = 0.12205568 +- 0.00090798 Tm 14:06:49 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.12206 0.00091 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.12206 0.00091 0.12206 0.00000 14:06:49 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.12206 0.00091 SL = 0.1220557 +- 0.0009080 Tm^2/m^n 14:06:49 Magnet Strength Measurement Harmonic Number = 1 SL = 0.1220557 +- 0.0009080 Tm^2/m^n 14:06:51 Magnet Current, Imag = 49.6423 A Vtrans = 0.496423 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:06:52 Magnet Current, Imag = 49.6369 A Vtrans = 0.496369 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:06:54 Magnet Current, Imag = 49.6528 A Vtrans = 0.496528 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:06:55 Magnet Current, Imag = 49.6519 A Vtrans = 0.496519 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:06:55 Magnet Current Measurement: Imag = 49.6460 +- 0.0067 A 14:06:55 Magnet current ramping to 100.0000 A... 14:07:17 Magnet Current, Imag = 99.6942 A Vtrans = 0.996942 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:07:19 Magnet Current, Imag = 99.6991 A Vtrans = 0.996991 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:07:20 Magnet Current, Imag = 99.7100 A Vtrans = 0.997100 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:07:22 Magnet Current, Imag = 99.7024 A Vtrans = 0.997024 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:07:22 Magnet Current Measurement: Imag = 99.7014 +- 0.0057 A 14:07:22 Magnetic Field Measurement Measuring the magnet strength... 14:07:22 Integrated Voltage Measurement... 14:07:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002290949 Vs 14:07:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002531263 Vs 14:07:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002299630 Vs 14:08:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002522017 Vs 14:08:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002298251 Vs 14:08:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002528829 Vs 14:08:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002297071 Vs 14:08:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.002525939 Vs 14:08:49 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.002411744 +- 0.000001065 Vs 14:08:49 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.002411744 +- 0.000001065 Vs BL = 0.24117436 +- 0.00010648 Tm 14:08:52 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.24117 0.00011 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.24117 0.00011 0.24117 0.00000 14:08:52 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.24117 0.00011 SL = 0.2411744 +- 0.0001065 Tm^2/m^n 14:08:52 Magnet Strength Measurement Harmonic Number = 1 SL = 0.2411744 +- 0.0001065 Tm^2/m^n 14:08:53 Magnet Current, Imag = 99.6990 A Vtrans = 0.996990 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:08:55 Magnet Current, Imag = 99.6768 A Vtrans = 0.996768 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:08:56 Magnet Current, Imag = 99.6823 A Vtrans = 0.996823 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:08:57 Magnet Current, Imag = 99.6791 A Vtrans = 0.996791 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:08:57 Magnet Current Measurement: Imag = 99.6843 +- 0.0087 A 14:08:57 Magnet current ramping to 150.0000 A... 14:09:20 Magnet Current, Imag = 149.7398 A Vtrans = 1.497398 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:09:21 Magnet Current, Imag = 149.7377 A Vtrans = 1.497377 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:09:23 Magnet Current, Imag = 149.7330 A Vtrans = 1.497330 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:09:24 Magnet Current, Imag = 149.7368 A Vtrans = 1.497368 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:09:24 Magnet Current Measurement: Imag = 149.7368 +- 0.0025 A 14:09:24 Magnetic Field Measurement Measuring the magnet strength... 14:09:24 Integrated Voltage Measurement... 14:09:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003491759 Vs 14:09:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003732704 Vs 14:09:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003515457 Vs 14:10:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003738966 Vs 14:10:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003506949 Vs 14:10:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003742701 Vs 14:10:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003506104 Vs 14:10:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.003735262 Vs 14:10:51 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.003621238 +- 0.000005700 Vs 14:10:51 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.003621238 +- 0.000005700 Vs BL = 0.36212377 +- 0.00057004 Tm 14:10:54 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.36212 0.00057 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.36212 0.00057 0.36212 0.00000 14:10:54 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.36212 0.00057 SL = 0.3621238 +- 0.0005700 Tm^2/m^n 14:10:54 Magnet Strength Measurement Harmonic Number = 1 SL = 0.3621238 +- 0.0005700 Tm^2/m^n 14:10:55 Magnet Current, Imag = 149.7397 A Vtrans = 1.497397 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:10:57 Magnet Current, Imag = 149.7374 A Vtrans = 1.497374 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:10:58 Magnet Current, Imag = 149.7297 A Vtrans = 1.497297 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:11:00 Magnet Current, Imag = 149.7442 A Vtrans = 1.497442 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:11:00 Magnet Current Measurement: Imag = 149.7378 +- 0.0053 A 14:11:00 Magnet current ramping to 200.0000 A... 14:11:22 Magnet Current, Imag = 199.7865 A Vtrans = 1.997865 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:11:24 Magnet Current, Imag = 199.8090 A Vtrans = 1.998090 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:11:25 Magnet Current, Imag = 199.7944 A Vtrans = 1.997944 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:11:27 Magnet Current, Imag = 199.7977 A Vtrans = 1.997977 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:11:27 Magnet Current Measurement: Imag = 199.7969 +- 0.0081 A 14:11:27 Magnetic Field Measurement Measuring the magnet strength... 14:11:27 Integrated Voltage Measurement... 14:11:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004715703 Vs 14:11:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004942177 Vs 14:12:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004724127 Vs 14:12:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004950365 Vs 14:12:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004710881 Vs 14:12:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004952131 Vs 14:12:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004714808 Vs 14:12:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.004953953 Vs 14:12:54 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.004833018 +- 0.000003108 Vs 14:12:54 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.004833018 +- 0.000003108 Vs BL = 0.48330180 +- 0.00031082 Tm 14:12:57 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.48330 0.00031 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.48330 0.00031 0.48330 0.00000 14:12:57 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.48330 0.00031 SL = 0.4833018 +- 0.0003108 Tm^2/m^n 14:12:57 Magnet Strength Measurement Harmonic Number = 1 SL = 0.4833018 +- 0.0003108 Tm^2/m^n 14:12:58 Magnet Current, Imag = 199.7758 A Vtrans = 1.997758 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:13:00 Magnet Current, Imag = 199.7905 A Vtrans = 1.997905 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:13:01 Magnet Current, Imag = 199.8045 A Vtrans = 1.998045 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:13:02 Magnet Current, Imag = 199.7976 A Vtrans = 1.997976 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:13:02 Magnet Current Measurement: Imag = 199.7921 +- 0.0106 A 14:13:03 Magnet current ramping to 250.0000 A... 14:13:25 Magnet Current, Imag = 249.8269 A Vtrans = 2.498269 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:13:26 Magnet Current, Imag = 249.8231 A Vtrans = 2.498231 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:13:28 Magnet Current, Imag = 249.8185 A Vtrans = 2.498185 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:13:29 Magnet Current, Imag = 249.8073 A Vtrans = 2.498073 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:13:29 Magnet Current Measurement: Imag = 249.8190 +- 0.0074 A 14:13:29 Magnetic Field Measurement Measuring the magnet strength... 14:13:29 Integrated Voltage Measurement... 14:13:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005938407 Vs 14:13:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006174734 Vs 14:14:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005933164 Vs 14:14:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006164851 Vs 14:14:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005928286 Vs 14:14:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006158989 Vs 14:14:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.005928502 Vs 14:14:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.006159232 Vs 14:14:56 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.006048271 +- 0.000005251 Vs 14:14:56 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.006048271 +- 0.000005251 Vs BL = 0.60482706 +- 0.00052509 Tm 14:14:59 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.60483 0.00053 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.60483 0.00053 0.60483 0.00000 14:14:59 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.60483 0.00053 SL = 0.6048271 +- 0.0005251 Tm^2/m^n 14:14:59 Magnet Strength Measurement Harmonic Number = 1 SL = 0.6048271 +- 0.0005251 Tm^2/m^n 14:15:01 Magnet Current, Imag = 249.8760 A Vtrans = 2.498760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:15:02 Magnet Current, Imag = 249.8722 A Vtrans = 2.498722 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:15:04 Magnet Current, Imag = 249.8468 A Vtrans = 2.498468 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:15:05 Magnet Current, Imag = 249.8496 A Vtrans = 2.498496 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:15:05 Magnet Current Measurement: Imag = 249.8611 +- 0.0131 A 14:15:05 Magnet current ramping to 300.0000 A... 14:15:27 Magnet Current, Imag = 299.8583 A Vtrans = 2.998583 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:15:29 Magnet Current, Imag = 299.8693 A Vtrans = 2.998693 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:15:30 Magnet Current, Imag = 299.8697 A Vtrans = 2.998697 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:15:32 Magnet Current, Imag = 299.8693 A Vtrans = 2.998693 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:15:32 Magnet Current Measurement: Imag = 299.8666 +- 0.0048 A 14:15:32 Magnetic Field Measurement Measuring the magnet strength... 14:15:32 Integrated Voltage Measurement... 14:15:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007142671 Vs 14:15:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007377080 Vs 14:16:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007146482 Vs 14:16:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007372949 Vs 14:16:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007154776 Vs 14:16:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007368925 Vs 14:16:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007158482 Vs 14:17:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.007383567 Vs 14:17:00 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.007263117 +- 0.000004642 Vs 14:17:00 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.007263117 +- 0.000004642 Vs BL = 0.72631167 +- 0.00046425 Tm 14:17:03 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.72631 0.00046 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.72631 0.00046 0.72631 0.00000 14:17:03 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.72631 0.00046 SL = 0.7263117 +- 0.0004642 Tm^2/m^n 14:17:03 Magnet Strength Measurement Harmonic Number = 1 SL = 0.7263117 +- 0.0004642 Tm^2/m^n 14:17:04 Magnet Current, Imag = 299.8401 A Vtrans = 2.998401 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:17:06 Magnet Current, Imag = 299.8312 A Vtrans = 2.998312 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:17:07 Magnet Current, Imag = 299.8428 A Vtrans = 2.998428 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:17:09 Magnet Current, Imag = 299.8495 A Vtrans = 2.998495 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:17:09 Magnet Current Measurement: Imag = 299.8409 +- 0.0066 A 14:17:09 Magnet current ramping to 350.0000 A... 14:17:32 Magnet Current, Imag = 349.9350 A Vtrans = 3.499350 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:17:33 Magnet Current, Imag = 349.9190 A Vtrans = 3.499190 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:17:35 Magnet Current, Imag = 349.9150 A Vtrans = 3.499150 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:17:37 Magnet Current, Imag = 349.9500 A Vtrans = 3.499500 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:17:37 Magnet Current Measurement: Imag = 349.9298 +- 0.0139 A 14:17:37 Magnetic Field Measurement Measuring the magnet strength... 14:17:37 Integrated Voltage Measurement... 14:17:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.008339591 Vs 14:18:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008597631 Vs 14:18:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.008357195 Vs 14:18:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008579950 Vs 14:18:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.008350918 Vs 14:18:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008595043 Vs 14:18:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.008352601 Vs 14:19:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.008583445 Vs 14:19:05 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.008469547 +- 0.000001996 Vs 14:19:05 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.008469547 +- 0.000001996 Vs BL = 0.84695467 +- 0.00019962 Tm 14:19:08 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.84695 0.00020 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.84695 0.00020 0.84695 0.00000 14:19:08 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.84695 0.00020 SL = 0.8469547 +- 0.0001996 Tm^2/m^n 14:19:08 Magnet Strength Measurement Harmonic Number = 1 SL = 0.8469547 +- 0.0001996 Tm^2/m^n 14:19:10 Magnet Current, Imag = 349.9190 A Vtrans = 3.499190 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:19:12 Magnet Current, Imag = 349.9440 A Vtrans = 3.499440 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:19:14 Magnet Current, Imag = 349.9580 A Vtrans = 3.499580 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:19:16 Magnet Current, Imag = 349.9030 A Vtrans = 3.499030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:19:16 Magnet Current Measurement: Imag = 349.9310 +- 0.0214 A 14:19:16 Magnet current ramping to 400.0000 A... 14:19:39 Magnet Current, Imag = 399.9480 A Vtrans = 3.999480 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:19:40 Magnet Current, Imag = 399.9460 A Vtrans = 3.999460 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:19:42 Magnet Current, Imag = 399.9590 A Vtrans = 3.999590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:19:43 Magnet Current, Imag = 399.9600 A Vtrans = 3.999600 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:19:43 Magnet Current Measurement: Imag = 399.9532 +- 0.0063 A 14:19:44 Magnetic Field Measurement Measuring the magnet strength... 14:19:44 Integrated Voltage Measurement... 14:19:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009554909 Vs 14:20:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009790134 Vs 14:20:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009566071 Vs 14:20:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009814290 Vs 14:20:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009562255 Vs 14:20:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009810039 Vs 14:21:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009561781 Vs 14:21:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009798932 Vs 14:21:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009682301 +- 0.000006639 Vs 14:21:10 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.009682301 +- 0.000006639 Vs BL = 0.96823014 +- 0.00066389 Tm 14:21:13 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.96823 0.00066 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.96823 0.00066 0.96823 0.00000 14:21:13 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.96823 0.00066 SL = 0.9682301 +- 0.0006639 Tm^2/m^n 14:21:13 Magnet Strength Measurement Harmonic Number = 1 SL = 0.9682301 +- 0.0006639 Tm^2/m^n 14:21:15 Magnet Current, Imag = 399.9360 A Vtrans = 3.999360 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:21:16 Magnet Current, Imag = 399.9430 A Vtrans = 3.999430 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:21:18 Magnet Current, Imag = 399.9400 A Vtrans = 3.999400 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:21:20 Magnet Current, Imag = 399.9190 A Vtrans = 3.999190 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:21:20 Magnet Current Measurement: Imag = 399.9345 +- 0.0093 A 14:21:20 Magnet current ramping to 450.0000 A... 14:21:42 Magnet Current, Imag = 450.0280 A Vtrans = 4.500280 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:21:44 Magnet Current, Imag = 450.0220 A Vtrans = 4.500220 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:21:45 Magnet Current, Imag = 449.9920 A Vtrans = 4.499920 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:21:47 Magnet Current, Imag = 449.9950 A Vtrans = 4.499950 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:21:47 Magnet Current Measurement: Imag = 450.0093 +- 0.0159 A 14:21:47 Magnetic Field Measurement Measuring the magnet strength... 14:21:47 Integrated Voltage Measurement... 14:22:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010774853 Vs 14:22:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011001358 Vs 14:22:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010768375 Vs 14:22:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011004413 Vs 14:22:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010774186 Vs 14:22:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011007479 Vs 14:23:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010768787 Vs 14:23:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011012407 Vs 14:23:14 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010888982 +- 0.000001837 Vs 14:23:14 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.010888982 +- 0.000001837 Vs BL = 1.08889822 +- 0.00018371 Tm 14:23:17 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.08890 0.00018 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.08890 0.00018 1.08890 0.00000 14:23:17 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.08890 0.00018 SL = 1.0888982 +- 0.0001837 Tm^2/m^n 14:23:17 Magnet Strength Measurement Harmonic Number = 1 SL = 1.0888982 +- 0.0001837 Tm^2/m^n 14:23:18 Magnet Current, Imag = 449.9960 A Vtrans = 4.499960 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:23:20 Magnet Current, Imag = 449.9830 A Vtrans = 4.499830 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:23:21 Magnet Current, Imag = 449.9760 A Vtrans = 4.499760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:23:23 Magnet Current, Imag = 449.9750 A Vtrans = 4.499750 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:23:23 Magnet Current Measurement: Imag = 449.9825 +- 0.0084 A 14:23:23 Magnet current ramping to 500.0000 A... 14:23:46 Magnet Current, Imag = 500.0880 A Vtrans = 5.000880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:23:47 Magnet Current, Imag = 500.0800 A Vtrans = 5.000800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:23:49 Magnet Current, Imag = 500.0730 A Vtrans = 5.000730 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:23:50 Magnet Current, Imag = 500.0740 A Vtrans = 5.000740 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:23:50 Magnet Current Measurement: Imag = 500.0788 +- 0.0060 A 14:23:50 Magnetic Field Measurement Measuring the magnet strength... 14:23:50 Integrated Voltage Measurement... 14:24:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011974169 Vs 14:24:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012207917 Vs 14:24:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011981472 Vs 14:24:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012205930 Vs 14:24:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011973699 Vs 14:24:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012207451 Vs 14:25:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.011978902 Vs 14:25:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012206038 Vs 14:25:17 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012091947 +- 0.000001230 Vs 14:25:17 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.012091947 +- 0.000001230 Vs BL = 1.20919472 +- 0.00012299 Tm 14:25:20 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.20919 0.00012 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.20919 0.00012 1.20919 0.00000 14:25:20 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.20919 0.00012 SL = 1.2091947 +- 0.0001230 Tm^2/m^n 14:25:20 Magnet Strength Measurement Harmonic Number = 1 SL = 1.2091947 +- 0.0001230 Tm^2/m^n 14:25:22 Magnet Current, Imag = 500.0710 A Vtrans = 5.000710 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:25:23 Magnet Current, Imag = 500.0640 A Vtrans = 5.000640 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:25:25 Magnet Current, Imag = 500.0570 A Vtrans = 5.000570 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:25:26 Magnet Current, Imag = 500.0590 A Vtrans = 5.000590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:25:26 Magnet Current Measurement: Imag = 500.0627 +- 0.0054 A 14:25:27 Magnet current ramping to 525.0000 A... 14:25:42 Magnet Current, Imag = 525.0680 A Vtrans = 5.250680 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:25:44 Magnet Current, Imag = 525.0870 A Vtrans = 5.250870 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:25:45 Magnet Current, Imag = 525.0840 A Vtrans = 5.250840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:25:47 Magnet Current, Imag = 525.0810 A Vtrans = 5.250810 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:25:47 Magnet Current Measurement: Imag = 525.0800 +- 0.0072 A 14:25:47 Magnetic Field Measurement Measuring the magnet strength... 14:25:47 Integrated Voltage Measurement... 14:26:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012577897 Vs 14:26:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012807077 Vs 14:26:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012578113 Vs 14:26:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012804920 Vs 14:26:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012577966 Vs 14:26:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012809847 Vs 14:27:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012566629 Vs 14:27:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012801307 Vs 14:27:15 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012690469 +- 0.000003849 Vs 14:27:15 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.012690469 +- 0.000003849 Vs BL = 1.26904695 +- 0.00038487 Tm 14:27:18 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.26905 0.00038 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.26905 0.00038 1.26905 0.00000 14:27:18 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.26905 0.00038 SL = 1.2690469 +- 0.0003849 Tm^2/m^n 14:27:18 Magnet Strength Measurement Harmonic Number = 1 SL = 1.2690469 +- 0.0003849 Tm^2/m^n 14:27:19 Magnet Current, Imag = 525.0980 A Vtrans = 5.250980 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:27:21 Magnet Current, Imag = 525.0900 A Vtrans = 5.250900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:27:22 Magnet Current, Imag = 525.0710 A Vtrans = 5.250710 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:27:24 Magnet Current, Imag = 525.0850 A Vtrans = 5.250850 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:27:24 Magnet Current Measurement: Imag = 525.0860 +- 0.0098 A 14:27:24 Magnet current ramping to 550.0000 A... 14:27:39 Magnet Current, Imag = 550.0610 A Vtrans = 5.500610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:27:41 Magnet Current, Imag = 550.0790 A Vtrans = 5.500790 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:27:42 Magnet Current, Imag = 550.0760 A Vtrans = 5.500760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:27:44 Magnet Current, Imag = 550.0580 A Vtrans = 5.500580 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:27:44 Magnet Current Measurement: Imag = 550.0685 +- 0.0091 A 14:27:44 Magnetic Field Measurement Measuring the magnet strength... 14:27:44 Integrated Voltage Measurement... 14:27:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013162878 Vs 14:28:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013402088 Vs 14:28:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013156499 Vs 14:28:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013395474 Vs 14:28:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013159093 Vs 14:28:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013406848 Vs 14:29:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013162848 Vs 14:29:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013401235 Vs 14:29:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013280870 +- 0.000002839 Vs 14:29:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.013280870 +- 0.000002839 Vs BL = 1.32808704 +- 0.00028387 Tm 14:29:14 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.32809 0.00028 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.32809 0.00028 1.32809 0.00000 14:29:14 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.32809 0.00028 SL = 1.3280870 +- 0.0002839 Tm^2/m^n 14:29:14 Magnet Strength Measurement Harmonic Number = 1 SL = 1.3280870 +- 0.0002839 Tm^2/m^n 14:29:16 Magnet Current, Imag = 550.0840 A Vtrans = 5.500840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:29:17 Magnet Current, Imag = 550.0920 A Vtrans = 5.500920 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:29:19 Magnet Current, Imag = 550.1100 A Vtrans = 5.501100 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:29:20 Magnet Current, Imag = 550.0800 A Vtrans = 5.500800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:29:20 Magnet Current Measurement: Imag = 550.0915 +- 0.0115 A 14:29:20 Magnet current ramping to 575.0000 A... 14:29:36 Magnet Current, Imag = 575.1120 A Vtrans = 5.751120 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:29:37 Magnet Current, Imag = 575.0800 A Vtrans = 5.750800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:29:39 Magnet Current, Imag = 575.0880 A Vtrans = 5.750880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:29:41 Magnet Current, Imag = 575.0960 A Vtrans = 5.750960 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:29:41 Magnet Current Measurement: Imag = 575.0940 +- 0.0118 A 14:29:41 Magnetic Field Measurement Measuring the magnet strength... 14:29:41 Integrated Voltage Measurement... 14:29:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013754200 Vs 14:30:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013984839 Vs 14:30:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013745191 Vs 14:30:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013995329 Vs 14:30:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013747927 Vs 14:30:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013985870 Vs 14:30:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013746455 Vs 14:31:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013989156 Vs 14:31:09 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013868621 +- 0.000001335 Vs 14:31:09 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.013868621 +- 0.000001335 Vs BL = 1.38686208 +- 0.00013346 Tm 14:31:12 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.38686 0.00013 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.38686 0.00013 1.38686 0.00000 14:31:12 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.38686 0.00013 SL = 1.3868621 +- 0.0001335 Tm^2/m^n 14:31:12 Magnet Strength Measurement Harmonic Number = 1 SL = 1.3868621 +- 0.0001335 Tm^2/m^n 14:31:13 Magnet Current, Imag = 575.0930 A Vtrans = 5.750930 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:31:15 Magnet Current, Imag = 575.0670 A Vtrans = 5.750670 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:31:16 Magnet Current, Imag = 575.0780 A Vtrans = 5.750780 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:31:18 Magnet Current, Imag = 575.0960 A Vtrans = 5.750960 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:31:18 Magnet Current Measurement: Imag = 575.0835 +- 0.0117 A 14:31:18 Magnet current ramping to 600.0000 A... 14:31:33 Magnet Current, Imag = 600.1140 A Vtrans = 6.001140 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:31:35 Magnet Current, Imag = 600.0720 A Vtrans = 6.000720 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:31:36 Magnet Current, Imag = 600.1290 A Vtrans = 6.001290 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:31:38 Magnet Current, Imag = 600.1390 A Vtrans = 6.001390 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:31:38 Magnet Current Measurement: Imag = 600.1135 +- 0.0256 A 14:31:38 Magnetic Field Measurement Measuring the magnet strength... 14:31:38 Integrated Voltage Measurement... 14:31:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014321482 Vs 14:32:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014562398 Vs 14:32:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014322904 Vs 14:32:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014558931 Vs 14:32:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014326727 Vs 14:32:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014559263 Vs 14:32:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014327049 Vs 14:33:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014570897 Vs 14:33:05 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014443706 +- 0.000003128 Vs 14:33:05 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.014443706 +- 0.000003128 Vs BL = 1.44437062 +- 0.00031280 Tm 14:33:08 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.44437 0.00031 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.44437 0.00031 1.44437 0.00000 14:33:08 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.44437 0.00031 SL = 1.4443706 +- 0.0003128 Tm^2/m^n 14:33:08 Magnet Strength Measurement Harmonic Number = 1 SL = 1.4443706 +- 0.0003128 Tm^2/m^n 14:33:09 Magnet Current, Imag = 600.0960 A Vtrans = 6.000960 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:33:11 Magnet Current, Imag = 600.1390 A Vtrans = 6.001390 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:33:12 Magnet Current, Imag = 600.1750 A Vtrans = 6.001750 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:33:14 Magnet Current, Imag = 600.1110 A Vtrans = 6.001110 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:33:14 Magnet Current Measurement: Imag = 600.1303 +- 0.0301 A 14:33:14 Magnet current ramping to 625.0000 A... 14:33:30 Magnet Current, Imag = 625.1470 A Vtrans = 6.251470 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:33:31 Magnet Current, Imag = 625.1390 A Vtrans = 6.251390 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:33:33 Magnet Current, Imag = 625.1460 A Vtrans = 6.251460 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:33:34 Magnet Current, Imag = 625.1590 A Vtrans = 6.251590 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:33:34 Magnet Current Measurement: Imag = 625.1477 +- 0.0072 A 14:33:34 Magnetic Field Measurement Measuring the magnet strength... 14:33:34 Integrated Voltage Measurement... 14:33:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014883334 Vs 14:33:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015118434 Vs 14:34:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014880881 Vs 14:34:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015128994 Vs 14:34:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014883727 Vs 14:34:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015121692 Vs 14:34:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014887724 Vs 14:35:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015118544 Vs 14:35:01 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015002916 +- 0.000001441 Vs 14:35:01 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.015002916 +- 0.000001441 Vs BL = 1.50029162 +- 0.00014409 Tm 14:35:04 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.50029 0.00014 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.50029 0.00014 1.50029 0.00000 14:35:04 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.50029 0.00014 SL = 1.5002916 +- 0.0001441 Tm^2/m^n 14:35:04 Magnet Strength Measurement Harmonic Number = 1 SL = 1.5002916 +- 0.0001441 Tm^2/m^n 14:35:06 Magnet Current, Imag = 625.1610 A Vtrans = 6.251610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:35:07 Magnet Current, Imag = 625.1770 A Vtrans = 6.251770 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:35:09 Magnet Current, Imag = 625.1800 A Vtrans = 6.251800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:35:10 Magnet Current, Imag = 625.1880 A Vtrans = 6.251880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:35:10 Magnet Current Measurement: Imag = 625.1765 +- 0.0098 A 14:35:11 Magnet current ramping to 650.0000 A... 14:35:26 Magnet Current, Imag = 650.1820 A Vtrans = 6.501820 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:35:28 Magnet Current, Imag = 650.1810 A Vtrans = 6.501810 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:35:29 Magnet Current, Imag = 650.2130 A Vtrans = 6.502130 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:35:31 Magnet Current, Imag = 650.1890 A Vtrans = 6.501890 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:35:31 Magnet Current Measurement: Imag = 650.1912 +- 0.0129 A 14:35:31 Magnetic Field Measurement Measuring the magnet strength... 14:35:31 Integrated Voltage Measurement... 14:35:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015407062 Vs 14:35:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015647358 Vs 14:36:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015423851 Vs 14:36:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015659007 Vs 14:36:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015408685 Vs 14:36:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015651571 Vs 14:36:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015420582 Vs 14:36:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015659763 Vs 14:36:58 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015534735 +- 0.000006169 Vs 14:36:58 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.015534735 +- 0.000006169 Vs BL = 1.55347350 +- 0.00061691 Tm 14:37:01 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.55347 0.00062 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.55347 0.00062 1.55347 0.00000 14:37:01 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.55347 0.00062 SL = 1.5534735 +- 0.0006169 Tm^2/m^n 14:37:01 Magnet Strength Measurement Harmonic Number = 1 SL = 1.5534735 +- 0.0006169 Tm^2/m^n 14:37:02 Magnet Current, Imag = 650.2110 A Vtrans = 6.502110 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:37:04 Magnet Current, Imag = 650.1920 A Vtrans = 6.501920 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:37:05 Magnet Current, Imag = 650.2280 A Vtrans = 6.502280 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:37:07 Magnet Current, Imag = 650.2090 A Vtrans = 6.502090 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:37:07 Magnet Current Measurement: Imag = 650.2100 +- 0.0127 A 14:37:07 Magnet current ramping to 675.0000 A... 14:37:23 Magnet Current, Imag = 675.2440 A Vtrans = 6.752440 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:37:24 Magnet Current, Imag = 675.2330 A Vtrans = 6.752330 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:37:26 Magnet Current, Imag = 675.2250 A Vtrans = 6.752250 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:37:27 Magnet Current, Imag = 675.2180 A Vtrans = 6.752180 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:37:27 Magnet Current Measurement: Imag = 675.2300 +- 0.0097 A 14:37:27 Magnetic Field Measurement Measuring the magnet strength... 14:37:27 Integrated Voltage Measurement... 14:37:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015912491 Vs 14:37:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016160278 Vs 14:38:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015916486 Vs 14:38:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016153489 Vs 14:38:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015911937 Vs 14:38:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016151348 Vs 14:38:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015916550 Vs 14:38:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016161884 Vs 14:38:54 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016035558 +- 0.000002726 Vs 14:38:54 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.016035558 +- 0.000002726 Vs BL = 1.60355578 +- 0.00027261 Tm 14:38:57 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.60356 0.00027 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.60356 0.00027 1.60356 0.00000 14:38:57 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.60356 0.00027 SL = 1.6035558 +- 0.0002726 Tm^2/m^n 14:38:57 Magnet Strength Measurement Harmonic Number = 1 SL = 1.6035558 +- 0.0002726 Tm^2/m^n 14:38:59 Magnet Current, Imag = 675.2330 A Vtrans = 6.752330 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:39:00 Magnet Current, Imag = 675.2470 A Vtrans = 6.752470 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:39:02 Magnet Current, Imag = 675.2290 A Vtrans = 6.752290 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:39:03 Magnet Current, Imag = 675.2180 A Vtrans = 6.752180 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:39:04 Magnet Current Measurement: Imag = 675.2317 +- 0.0104 A 14:39:04 Magnet current ramping to 700.0000 A... 14:39:19 Magnet Current, Imag = 700.2530 A Vtrans = 7.002530 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:39:21 Magnet Current, Imag = 700.2560 A Vtrans = 7.002560 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:39:22 Magnet Current, Imag = 700.2210 A Vtrans = 7.002210 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:39:24 Magnet Current, Imag = 700.2500 A Vtrans = 7.002500 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:39:24 Magnet Current Measurement: Imag = 700.2450 +- 0.0140 A 14:39:24 Magnetic Field Measurement Measuring the magnet strength... 14:39:24 Integrated Voltage Measurement... 14:39:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016383794 Vs 14:39:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016625585 Vs 14:39:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016387330 Vs 14:40:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016624527 Vs 14:40:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016382959 Vs 14:40:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016623731 Vs 14:40:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016383749 Vs 14:40:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.016619999 Vs 14:40:51 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.016503959 +- 0.000001511 Vs 14:40:51 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.016503959 +- 0.000001511 Vs BL = 1.65039592 +- 0.00015115 Tm 14:40:54 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.65040 0.00015 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.65040 0.00015 1.65040 0.00000 14:40:54 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.65040 0.00015 SL = 1.6503959 +- 0.0001511 Tm^2/m^n 14:40:54 Magnet Strength Measurement Harmonic Number = 1 SL = 1.6503959 +- 0.0001511 Tm^2/m^n 14:40:55 Magnet Current, Imag = 700.2230 A Vtrans = 7.002230 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:40:57 Magnet Current, Imag = 700.2560 A Vtrans = 7.002560 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:40:58 Magnet Current, Imag = 700.2200 A Vtrans = 7.002200 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:41:00 Magnet Current, Imag = 700.2450 A Vtrans = 7.002450 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:41:00 Magnet Current Measurement: Imag = 700.2360 +- 0.0150 A 14:41:00 Magnet current ramping to 650.0000 A... 14:41:23 Magnet Current, Imag = 650.1750 A Vtrans = 6.501750 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:41:24 Magnet Current, Imag = 650.1910 A Vtrans = 6.501910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:41:26 Magnet Current, Imag = 650.2030 A Vtrans = 6.502030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:41:27 Magnet Current, Imag = 650.1920 A Vtrans = 6.501920 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:41:27 Magnet Current Measurement: Imag = 650.1902 +- 0.0100 A 14:41:27 Magnetic Field Measurement Measuring the magnet strength... 14:41:27 Integrated Voltage Measurement... 14:41:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015480455 Vs 14:41:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015714147 Vs 14:42:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015479366 Vs 14:42:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015713080 Vs 14:42:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015481951 Vs 14:42:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015717007 Vs 14:42:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015476440 Vs 14:42:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.015709295 Vs 14:42:55 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.015596468 +- 0.000002386 Vs 14:42:55 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.015596468 +- 0.000002386 Vs BL = 1.55964677 +- 0.00023865 Tm 14:42:57 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.55965 0.00024 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.55965 0.00024 1.55965 0.00000 14:42:58 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.55965 0.00024 SL = 1.5596468 +- 0.0002386 Tm^2/m^n 14:42:58 Magnet Strength Measurement Harmonic Number = 1 SL = 1.5596468 +- 0.0002386 Tm^2/m^n 14:42:59 Magnet Current, Imag = 650.1880 A Vtrans = 6.501880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:43:01 Magnet Current, Imag = 650.2040 A Vtrans = 6.502040 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:43:02 Magnet Current, Imag = 650.2180 A Vtrans = 6.502180 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:43:04 Magnet Current, Imag = 650.1930 A Vtrans = 6.501930 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:43:04 Magnet Current Measurement: Imag = 650.2007 +- 0.0115 A 14:43:04 Magnet current ramping to 600.0000 A... 14:43:26 Magnet Current, Imag = 600.1250 A Vtrans = 6.001250 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:43:28 Magnet Current, Imag = 600.1200 A Vtrans = 6.001200 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:43:30 Magnet Current, Imag = 600.1130 A Vtrans = 6.001130 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:43:31 Magnet Current, Imag = 600.1180 A Vtrans = 6.001180 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:43:31 Magnet Current Measurement: Imag = 600.1190 +- 0.0043 A 14:43:31 Magnetic Field Measurement Measuring the magnet strength... 14:43:31 Integrated Voltage Measurement... 14:43:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014382151 Vs 14:43:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014627531 Vs 14:44:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014394813 Vs 14:44:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014625051 Vs 14:44:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014389337 Vs 14:44:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014621989 Vs 14:44:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014388997 Vs 14:44:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.014628508 Vs 14:44:58 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.014507297 +- 0.000002107 Vs 14:44:58 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.014507297 +- 0.000002107 Vs BL = 1.45072972 +- 0.00021074 Tm 14:45:01 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.45073 0.00021 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.45073 0.00021 1.45073 0.00000 14:45:01 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.45073 0.00021 SL = 1.4507297 +- 0.0002107 Tm^2/m^n 14:45:01 Magnet Strength Measurement Harmonic Number = 1 SL = 1.4507297 +- 0.0002107 Tm^2/m^n 14:45:03 Magnet Current, Imag = 600.1110 A Vtrans = 6.001110 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:45:04 Magnet Current, Imag = 600.1060 A Vtrans = 6.001060 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:45:06 Magnet Current, Imag = 600.1430 A Vtrans = 6.001430 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:45:07 Magnet Current, Imag = 600.1340 A Vtrans = 6.001340 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:45:07 Magnet Current Measurement: Imag = 600.1235 +- 0.0154 A 14:45:07 Magnet current ramping to 550.0000 A... 14:45:30 Magnet Current, Imag = 550.0410 A Vtrans = 5.500410 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:45:31 Magnet Current, Imag = 550.0470 A Vtrans = 5.500470 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:45:33 Magnet Current, Imag = 550.0420 A Vtrans = 5.500420 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:45:35 Magnet Current, Imag = 550.0480 A Vtrans = 5.500480 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:45:35 Magnet Current Measurement: Imag = 550.0445 +- 0.0030 A 14:45:35 Magnetic Field Measurement Measuring the magnet strength... 14:45:35 Integrated Voltage Measurement... 14:45:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013224626 Vs 14:45:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013450033 Vs 14:46:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013221199 Vs 14:46:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013458609 Vs 14:46:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013221608 Vs 14:46:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013456725 Vs 14:46:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013216323 Vs 14:47:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.013440336 Vs 14:47:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.013336182 +- 0.000004630 Vs 14:47:02 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.013336182 +- 0.000004630 Vs BL = 1.33361823 +- 0.00046297 Tm 14:47:05 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.33362 0.00046 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.33362 0.00046 1.33362 0.00000 14:47:05 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.33362 0.00046 SL = 1.3336182 +- 0.0004630 Tm^2/m^n 14:47:05 Magnet Strength Measurement Harmonic Number = 1 SL = 1.3336182 +- 0.0004630 Tm^2/m^n 14:47:06 Magnet Current, Imag = 550.0630 A Vtrans = 5.500630 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:47:08 Magnet Current, Imag = 550.0520 A Vtrans = 5.500520 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:47:09 Magnet Current, Imag = 550.0580 A Vtrans = 5.500580 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:47:11 Magnet Current, Imag = 550.0740 A Vtrans = 5.500740 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:47:11 Magnet Current Measurement: Imag = 550.0618 +- 0.0081 A 14:47:11 Magnet current ramping to 500.0000 A... 14:47:34 Magnet Current, Imag = 500.0910 A Vtrans = 5.000910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:47:35 Magnet Current, Imag = 500.0750 A Vtrans = 5.000750 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:47:37 Magnet Current, Imag = 500.0810 A Vtrans = 5.000810 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:47:38 Magnet Current, Imag = 500.0920 A Vtrans = 5.000920 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:47:38 Magnet Current Measurement: Imag = 500.0847 +- 0.0071 A 14:47:38 Magnetic Field Measurement Measuring the magnet strength... 14:47:38 Integrated Voltage Measurement... 14:47:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012026741 Vs 14:48:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012267995 Vs 14:48:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012028763 Vs 14:48:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012272181 Vs 14:48:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012026679 Vs 14:48:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012262971 Vs 14:48:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012025774 Vs 14:49:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.012265141 Vs 14:49:05 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.012147031 +- 0.000002196 Vs 14:49:05 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.012147031 +- 0.000002196 Vs BL = 1.21470306 +- 0.00021962 Tm 14:49:08 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.21470 0.00022 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.21470 0.00022 1.21470 0.00000 14:49:08 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.21470 0.00022 SL = 1.2147031 +- 0.0002196 Tm^2/m^n 14:49:08 Magnet Strength Measurement Harmonic Number = 1 SL = 1.2147031 +- 0.0002196 Tm^2/m^n 14:49:10 Magnet Current, Imag = 500.0580 A Vtrans = 5.000580 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:49:11 Magnet Current, Imag = 500.0600 A Vtrans = 5.000600 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:49:13 Magnet Current, Imag = 500.0760 A Vtrans = 5.000760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:49:14 Magnet Current, Imag = 500.0790 A Vtrans = 5.000790 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:49:15 Magnet Current Measurement: Imag = 500.0682 +- 0.0093 A 14:49:15 Magnet current ramping to 450.0000 A... 14:49:37 Magnet Current, Imag = 450.0170 A Vtrans = 4.500170 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:49:39 Magnet Current, Imag = 449.9970 A Vtrans = 4.499970 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:49:40 Magnet Current, Imag = 449.9890 A Vtrans = 4.499890 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:49:42 Magnet Current, Imag = 449.9680 A Vtrans = 4.499680 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:49:42 Magnet Current Measurement: Imag = 449.9928 +- 0.0176 A 14:49:42 Magnetic Field Measurement Measuring the magnet strength... 14:49:42 Integrated Voltage Measurement... 14:49:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010807531 Vs 14:50:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011054210 Vs 14:50:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010817513 Vs 14:50:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011047657 Vs 14:50:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010811682 Vs 14:50:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011053796 Vs 14:50:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010816670 Vs 14:51:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.011051402 Vs 14:51:09 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.010932558 +- 0.000001125 Vs 14:51:09 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.010932558 +- 0.000001125 Vs BL = 1.09325577 +- 0.00011253 Tm 14:51:12 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.09326 0.00011 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 1.09326 0.00011 1.09326 0.00000 14:51:12 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.09326 0.00011 SL = 1.0932558 +- 0.0001125 Tm^2/m^n 14:51:12 Magnet Strength Measurement Harmonic Number = 1 SL = 1.0932558 +- 0.0001125 Tm^2/m^n 14:51:14 Magnet Current, Imag = 449.9740 A Vtrans = 4.499740 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:51:15 Magnet Current, Imag = 449.9880 A Vtrans = 4.499880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:51:17 Magnet Current, Imag = 449.9840 A Vtrans = 4.499840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:51:18 Magnet Current, Imag = 449.9880 A Vtrans = 4.499880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:51:18 Magnet Current Measurement: Imag = 449.9835 +- 0.0057 A 14:51:19 Magnet current ramping to 400.0000 A... 14:51:41 Magnet Current, Imag = 399.9090 A Vtrans = 3.999090 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:51:43 Magnet Current, Imag = 399.9130 A Vtrans = 3.999130 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:51:44 Magnet Current, Imag = 399.9120 A Vtrans = 3.999120 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:51:46 Magnet Current, Imag = 399.9030 A Vtrans = 3.999030 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:51:46 Magnet Current Measurement: Imag = 399.9092 +- 0.0039 A 14:51:46 Magnetic Field Measurement Measuring the magnet strength... 14:51:46 Integrated Voltage Measurement... 14:51:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009604122 Vs 14:52:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009841199 Vs 14:52:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009605321 Vs 14:52:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009839059 Vs 14:52:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009597216 Vs 14:52:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009835915 Vs 14:53:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009611077 Vs 14:53:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.009840871 Vs 14:53:13 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.009721848 +- 0.000003380 Vs 14:53:13 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.009721848 +- 0.000003380 Vs BL = 0.97218475 +- 0.00033804 Tm 14:53:16 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.97218 0.00034 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- 0.000000 0.97218 0.00034 0.97218 0.00000 14:53:16 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.97218 0.00034 SL = 0.9721848 +- 0.0003380 Tm^2/m^n 14:53:16 Magnet Strength Measurement Harmonic Number = 1 SL = 0.9721848 +- 0.0003380 Tm^2/m^n 14:53:17 Magnet Current, Imag = 399.9380 A Vtrans = 3.999380 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:53:19 Magnet Current, Imag = 399.9520 A Vtrans = 3.999520 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:53:20 Magnet Current, Imag = 399.9470 A Vtrans = 3.999470 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:53:22 Magnet Current, Imag = 399.9710 A Vtrans = 3.999710 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:53:22 Magnet Current Measurement: Imag = 399.9520 +- 0.0121 A 14:53:52 Magnet current ramping to 0.0000 A...