SLAC Magnetic Measurements Date: 08-16-2002 Time: 10:52:15 Project: SSRL Magnet Type: Solenoid Magnet Name: GTFsolenoid Serial Number: Run Number: 6 Measurement Device: B9900 Hall probe Operator: zw Comment: Bz vs z, x = -10 mm, y = 0 Standardization: 1 cycles from 0.0 A to 220.0 A to 0.0 A Test Currents (A): 100.0 150.0 10:52:26 Stage Zeroed 10:52:26 MoveZ Devices: Move Device = SXDRIVE, Read Device = SXDRIVE 10:53:30 Hall Probe Zeroed 10:53:50 Hall Probe Type Being Used, type = B9900 10:53:52 Initial Zero Current Measurement, Imag_zero = 0.0000 A 10:53:52 Magnet current ramping to 25.0000 A... 10:54:55 Hall Probe Range Set, range = 5 10:54:55 Magnet current ramping to 220.0000 A... 10:56:31 Magnet current ramping to 0.0000 A... 10:58:17 Hall Probe Range Set, range = 4 10:58:17 Magnet current ramping to 100.0000 A... 11:00:16 Move Stage, position = -0.250000 11:00:17 Stage Position Measurement, pos = -0.250000 m 11:00:19 Magnet Current, Imag = 100.0178 A Vtrans = 1.000178 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:00:19 Hall Probe Field Measurement, B = -0.000320 T 11:00:27 Move Stage, position = -0.240000 11:00:28 Stage Position Measurement, pos = -0.240000 m 11:00:29 Magnet Current, Imag = 100.0347 A Vtrans = 1.000347 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:00:30 Hall Probe Field Measurement, B = -0.000370 T 11:00:37 Move Stage, position = -0.230000 11:00:38 Stage Position Measurement, pos = -0.230000 m 11:00:40 Magnet Current, Imag = 100.0229 A Vtrans = 1.000229 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:00:40 Hall Probe Field Measurement, B = -0.000460 T 11:00:48 Move Stage, position = -0.220000 11:00:49 Stage Position Measurement, pos = -0.220000 m 11:00:50 Magnet Current, Imag = 100.0263 A Vtrans = 1.000263 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:00:51 Hall Probe Field Measurement, B = -0.000550 T 11:00:58 Move Stage, position = -0.210000 11:00:59 Stage Position Measurement, pos = -0.210000 m 11:01:01 Magnet Current, Imag = 100.0144 A Vtrans = 1.000144 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:01:02 Hall Probe Field Measurement, B = -0.000690 T 11:01:10 Move Stage, position = -0.200000 11:01:11 Stage Position Measurement, pos = -0.200000 m 11:01:12 Magnet Current, Imag = 100.0146 A Vtrans = 1.000146 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:01:13 Hall Probe Field Measurement, B = -0.000890 T 11:01:20 Move Stage, position = -0.190000 11:01:21 Stage Position Measurement, pos = -0.190000 m 11:01:23 Magnet Current, Imag = 100.0243 A Vtrans = 1.000243 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:01:23 Hall Probe Field Measurement, B = -0.001180 T 11:01:31 Move Stage, position = -0.180000 11:01:32 Stage Position Measurement, pos = -0.180000 m 11:01:33 Magnet Current, Imag = 100.0094 A Vtrans = 1.000094 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:01:34 Hall Probe Field Measurement, B = -0.001620 T 11:01:41 Move Stage, position = -0.170000 11:01:42 Stage Position Measurement, pos = -0.170000 m 11:01:44 Magnet Current, Imag = 100.0283 A Vtrans = 1.000283 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:01:44 Hall Probe Field Measurement, B = -0.002300 T 11:01:52 Move Stage, position = -0.160000 11:01:53 Stage Position Measurement, pos = -0.160000 m 11:01:54 Magnet Current, Imag = 100.0276 A Vtrans = 1.000276 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:01:55 Hall Probe Field Measurement, B = -0.003390 T 11:02:02 Move Stage, position = -0.150000 11:02:03 Stage Position Measurement, pos = -0.150000 m 11:02:05 Magnet Current, Imag = 100.0264 A Vtrans = 1.000264 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:02:05 Hall Probe Field Measurement, B = -0.005290 T 11:02:13 Move Stage, position = -0.140000 11:02:14 Stage Position Measurement, pos = -0.140000 m 11:02:15 Magnet Current, Imag = 100.0112 A Vtrans = 1.000112 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:02:16 Hall Probe Field Measurement, B = -0.008610 T 11:02:23 Move Stage, position = -0.130000 11:02:24 Stage Position Measurement, pos = -0.130000 m 11:02:25 Magnet Current, Imag = 100.0362 A Vtrans = 1.000362 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:02:26 Hall Probe Field Measurement, B = -0.014680 T 11:02:34 Move Stage, position = -0.120000 11:02:35 Stage Position Measurement, pos = -0.120000 m 11:02:36 Magnet Current, Imag = 100.0094 A Vtrans = 1.000094 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:02:36 Hall Probe Field Measurement, B = -0.025550 T 11:02:44 Move Stage, position = -0.110000 11:02:45 Stage Position Measurement, pos = -0.110000 m 11:02:46 Magnet Current, Imag = 100.0185 A Vtrans = 1.000185 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:02:47 Hall Probe Field Measurement, B = -0.043450 T 11:02:54 Move Stage, position = -0.100000 11:02:56 Stage Position Measurement, pos = -0.100000 m 11:02:57 Magnet Current, Imag = 100.0208 A Vtrans = 1.000208 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:02:57 Hall Probe Field Measurement, B = -0.068170 T 11:03:05 Move Stage, position = -0.090000 11:03:06 Stage Position Measurement, pos = -0.090000 m 11:03:07 Magnet Current, Imag = 100.0243 A Vtrans = 1.000243 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:03:08 Hall Probe Field Measurement, B = -0.093930 T 11:03:15 Move Stage, position = -0.080000 11:03:16 Stage Position Measurement, pos = -0.080000 m 11:03:18 Magnet Current, Imag = 100.0230 A Vtrans = 1.000230 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:03:18 Hall Probe Field Measurement, B = -0.114590 T 11:03:26 Move Stage, position = -0.070000 11:03:27 Stage Position Measurement, pos = -0.070000 m 11:03:28 Magnet Current, Imag = 100.0209 A Vtrans = 1.000209 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:03:29 Hall Probe Field Measurement, B = -0.128420 T 11:03:36 Move Stage, position = -0.060000 11:03:37 Stage Position Measurement, pos = -0.060000 m 11:03:39 Magnet Current, Imag = 100.0254 A Vtrans = 1.000254 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:03:39 Hall Probe Field Measurement, B = -0.137190 T 11:03:47 Move Stage, position = -0.050000 11:03:48 Stage Position Measurement, pos = -0.050000 m 11:03:49 Magnet Current, Imag = 100.0318 A Vtrans = 1.000318 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:03:50 Hall Probe Field Measurement, B = -0.142390 T 11:03:57 Move Stage, position = -0.040000 11:03:58 Stage Position Measurement, pos = -0.040000 m 11:04:00 Magnet Current, Imag = 100.0201 A Vtrans = 1.000201 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:04:00 Hall Probe Field Measurement, B = -0.145520 T 11:04:08 Move Stage, position = -0.030000 11:04:09 Stage Position Measurement, pos = -0.030000 m 11:04:10 Magnet Current, Imag = 100.0230 A Vtrans = 1.000230 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:04:11 Hall Probe Field Measurement, B = -0.147350 T 11:04:18 Move Stage, position = -0.020000 11:04:19 Stage Position Measurement, pos = -0.020000 m 11:04:21 Magnet Current, Imag = 100.0178 A Vtrans = 1.000178 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:04:21 Hall Probe Field Measurement, B = -0.148400 T 11:04:29 Move Stage, position = -0.010000 11:04:30 Stage Position Measurement, pos = -0.010000 m 11:04:32 Magnet Current, Imag = 100.0271 A Vtrans = 1.000271 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:04:32 Hall Probe Field Measurement, B = -0.149030 T 11:04:40 Move Stage, position = 0.000000 11:04:41 Stage Position Measurement, pos = 0.000000 m 11:04:42 Magnet Current, Imag = 100.0132 A Vtrans = 1.000132 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:04:43 Hall Probe Field Measurement, B = -0.149240 T 11:04:51 Move Stage, position = 0.010000 11:04:52 Stage Position Measurement, pos = 0.010000 m 11:04:53 Magnet Current, Imag = 100.0101 A Vtrans = 1.000101 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:04:54 Hall Probe Field Measurement, B = -0.149230 T 11:05:01 Move Stage, position = 0.020000 11:05:02 Stage Position Measurement, pos = 0.020000 m 11:05:04 Magnet Current, Imag = 100.0224 A Vtrans = 1.000224 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:05:04 Hall Probe Field Measurement, B = -0.148740 T 11:05:12 Move Stage, position = 0.030000 11:05:13 Stage Position Measurement, pos = 0.030000 m 11:05:14 Magnet Current, Imag = 100.0219 A Vtrans = 1.000219 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:05:14 Hall Probe Field Measurement, B = -0.147800 T 11:05:22 Move Stage, position = 0.040000 11:05:23 Stage Position Measurement, pos = 0.040000 m 11:05:24 Magnet Current, Imag = 100.0119 A Vtrans = 1.000119 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:05:25 Hall Probe Field Measurement, B = -0.145990 T 11:05:33 Move Stage, position = 0.050000 11:05:34 Stage Position Measurement, pos = 0.050000 m 11:05:35 Magnet Current, Imag = 99.9974 A Vtrans = 0.999974 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:05:35 Hall Probe Field Measurement, B = -0.142680 T 11:05:43 Move Stage, position = 0.060000 11:05:44 Stage Position Measurement, pos = 0.060000 m 11:05:45 Magnet Current, Imag = 100.0234 A Vtrans = 1.000234 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:05:46 Hall Probe Field Measurement, B = -0.137120 T 11:05:53 Move Stage, position = 0.070000 11:05:55 Stage Position Measurement, pos = 0.070000 m 11:05:56 Magnet Current, Imag = 100.0230 A Vtrans = 1.000230 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:05:56 Hall Probe Field Measurement, B = -0.127610 T 11:06:04 Move Stage, position = 0.080000 11:06:05 Stage Position Measurement, pos = 0.080000 m 11:06:06 Magnet Current, Imag = 100.0232 A Vtrans = 1.000232 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:06:07 Hall Probe Field Measurement, B = -0.112590 T 11:06:14 Move Stage, position = 0.090000 11:06:15 Stage Position Measurement, pos = 0.090000 m 11:06:17 Magnet Current, Imag = 100.0057 A Vtrans = 1.000057 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:06:17 Hall Probe Field Measurement, B = -0.090940 T 11:06:25 Move Stage, position = 0.100000 11:06:26 Stage Position Measurement, pos = 0.100000 m 11:06:27 Magnet Current, Imag = 100.0111 A Vtrans = 1.000111 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:06:28 Hall Probe Field Measurement, B = -0.064600 T 11:06:35 Move Stage, position = 0.110000 11:06:36 Stage Position Measurement, pos = 0.110000 m 11:06:38 Magnet Current, Imag = 100.0147 A Vtrans = 1.000147 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:06:38 Hall Probe Field Measurement, B = -0.040770 T 11:06:46 Move Stage, position = 0.120000 11:06:47 Stage Position Measurement, pos = 0.120000 m 11:06:48 Magnet Current, Imag = 100.0127 A Vtrans = 1.000127 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:06:49 Hall Probe Field Measurement, B = -0.023890 T 11:06:56 Move Stage, position = 0.130000 11:06:57 Stage Position Measurement, pos = 0.130000 m 11:06:59 Magnet Current, Imag = 100.0273 A Vtrans = 1.000273 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:06:59 Hall Probe Field Measurement, B = -0.013780 T 11:07:07 Move Stage, position = 0.140000 11:07:08 Stage Position Measurement, pos = 0.140000 m 11:07:09 Magnet Current, Imag = 100.0110 A Vtrans = 1.000110 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:07:10 Hall Probe Field Measurement, B = -0.008210 T 11:07:17 Move Stage, position = 0.150000 11:07:18 Stage Position Measurement, pos = 0.150000 m 11:07:20 Magnet Current, Imag = 100.0122 A Vtrans = 1.000122 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:07:20 Hall Probe Field Measurement, B = -0.005110 T 11:07:28 Move Stage, position = 0.160000 11:07:29 Stage Position Measurement, pos = 0.160000 m 11:07:30 Magnet Current, Imag = 100.0163 A Vtrans = 1.000163 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:07:31 Hall Probe Field Measurement, B = -0.003350 T 11:07:38 Move Stage, position = 0.170000 11:07:39 Stage Position Measurement, pos = 0.170000 m 11:07:41 Magnet Current, Imag = 100.0072 A Vtrans = 1.000072 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:07:41 Hall Probe Field Measurement, B = -0.002310 T 11:07:49 Move Stage, position = 0.180000 11:07:50 Stage Position Measurement, pos = 0.180000 m 11:07:51 Magnet Current, Imag = 100.0189 A Vtrans = 1.000189 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:07:51 Hall Probe Field Measurement, B = -0.001660 T 11:07:59 Move Stage, position = 0.190000 11:08:00 Stage Position Measurement, pos = 0.190000 m 11:08:01 Magnet Current, Imag = 100.0010 A Vtrans = 1.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:08:02 Hall Probe Field Measurement, B = -0.001250 T 11:08:10 Move Stage, position = 0.200000 11:08:11 Stage Position Measurement, pos = 0.200000 m 11:08:12 Magnet Current, Imag = 100.0051 A Vtrans = 1.000051 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:08:12 Hall Probe Field Measurement, B = -0.000970 T 11:08:20 Move Stage, position = 0.210000 11:08:21 Stage Position Measurement, pos = 0.210000 m 11:08:22 Magnet Current, Imag = 100.0116 A Vtrans = 1.000116 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:08:23 Hall Probe Field Measurement, B = -0.000780 T 11:08:31 Move Stage, position = 0.220000 11:08:32 Stage Position Measurement, pos = 0.220000 m 11:08:33 Magnet Current, Imag = 100.0137 A Vtrans = 1.000137 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:08:33 Hall Probe Field Measurement, B = -0.000640 T 11:08:41 Move Stage, position = 0.230000 11:08:42 Stage Position Measurement, pos = 0.230000 m 11:08:43 Magnet Current, Imag = 100.0078 A Vtrans = 1.000078 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:08:44 Hall Probe Field Measurement, B = -0.000540 T 11:08:52 Move Stage, position = 0.240000 11:08:53 Stage Position Measurement, pos = 0.240000 m 11:08:54 Magnet Current, Imag = 99.9987 A Vtrans = 0.999987 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:08:55 Hall Probe Field Measurement, B = -0.000460 T 11:09:02 Move Stage, position = 0.250000 11:09:03 Stage Position Measurement, pos = 0.250000 m 11:09:05 Magnet Current, Imag = 100.0059 A Vtrans = 1.000059 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:09:05 Hall Probe Field Measurement, B = -0.000390 T 11:10:01 Move Stage, position = 0.000000 11:10:05 Hall Probe Range Set, range = 4 11:10:05 Magnet current ramping to 150.0000 A... 11:11:48 Move Stage, position = -0.250000 11:11:49 Stage Position Measurement, pos = -0.250000 m 11:11:50 Magnet Current, Imag = 150.0540 A Vtrans = 1.500540 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:11:52 Hall Probe Field Measurement, B = -0.000490 T 11:11:59 Move Stage, position = -0.240000 11:12:00 Stage Position Measurement, pos = -0.240000 m 11:12:02 Magnet Current, Imag = 150.0600 A Vtrans = 1.500600 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:12:02 Hall Probe Field Measurement, B = -0.000580 T 11:12:10 Move Stage, position = -0.230000 11:12:11 Stage Position Measurement, pos = -0.230000 m 11:12:12 Magnet Current, Imag = 150.0435 A Vtrans = 1.500435 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:12:13 Hall Probe Field Measurement, B = -0.000690 T 11:12:20 Move Stage, position = -0.220000 11:12:21 Stage Position Measurement, pos = -0.220000 m 11:12:23 Magnet Current, Imag = 150.0569 A Vtrans = 1.500569 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:12:23 Hall Probe Field Measurement, B = -0.000850 T 11:12:31 Move Stage, position = -0.210000 11:12:32 Stage Position Measurement, pos = -0.210000 m 11:12:33 Magnet Current, Imag = 150.0526 A Vtrans = 1.500526 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:12:33 Hall Probe Field Measurement, B = -0.001050 T 11:12:41 Move Stage, position = -0.200000 11:12:42 Stage Position Measurement, pos = -0.200000 m 11:12:43 Magnet Current, Imag = 150.0562 A Vtrans = 1.500562 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:12:44 Hall Probe Field Measurement, B = -0.001360 T 11:12:52 Move Stage, position = -0.190000 11:12:53 Stage Position Measurement, pos = -0.190000 m 11:12:54 Magnet Current, Imag = 150.0466 A Vtrans = 1.500466 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:12:54 Hall Probe Field Measurement, B = -0.001790 T 11:13:02 Move Stage, position = -0.180000 11:13:03 Stage Position Measurement, pos = -0.180000 m 11:13:04 Magnet Current, Imag = 150.0372 A Vtrans = 1.500372 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:13:05 Hall Probe Field Measurement, B = -0.002440 T 11:13:12 Move Stage, position = -0.170000 11:13:14 Stage Position Measurement, pos = -0.170000 m 11:13:15 Magnet Current, Imag = 150.0444 A Vtrans = 1.500444 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:13:15 Hall Probe Field Measurement, B = -0.003460 T 11:13:23 Move Stage, position = -0.160000 11:13:24 Stage Position Measurement, pos = -0.160000 m 11:13:25 Magnet Current, Imag = 150.0483 A Vtrans = 1.500483 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:13:26 Hall Probe Field Measurement, B = -0.005110 T 11:13:33 Move Stage, position = -0.150000 11:13:34 Stage Position Measurement, pos = -0.150000 m 11:13:36 Magnet Current, Imag = 150.0290 A Vtrans = 1.500290 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:13:36 Hall Probe Field Measurement, B = -0.007930 T 11:13:44 Move Stage, position = -0.140000 11:13:45 Stage Position Measurement, pos = -0.140000 m 11:13:47 Magnet Current, Imag = 150.0524 A Vtrans = 1.500524 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:13:48 Hall Probe Field Measurement, B = -0.012940 T 11:13:55 Move Stage, position = -0.130000 11:13:56 Stage Position Measurement, pos = -0.130000 m 11:13:58 Magnet Current, Imag = 150.0456 A Vtrans = 1.500456 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:13:58 Hall Probe Field Measurement, B = -0.022040 T 11:14:06 Move Stage, position = -0.120000 11:14:07 Stage Position Measurement, pos = -0.120000 m 11:14:08 Magnet Current, Imag = 150.0472 A Vtrans = 1.500472 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:14:09 Hall Probe Field Measurement, B = -0.038350 T 11:14:16 Move Stage, position = -0.110000 11:14:17 Stage Position Measurement, pos = -0.110000 m 11:14:19 Magnet Current, Imag = 150.0482 A Vtrans = 1.500482 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:14:19 Hall Probe Field Measurement, B = -0.065190 T 11:14:27 Move Stage, position = -0.100000 11:14:28 Stage Position Measurement, pos = -0.100000 m 11:14:29 Magnet Current, Imag = 150.0517 A Vtrans = 1.500517 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:14:30 Hall Probe Field Measurement, B = -0.102220 T 11:14:37 Move Stage, position = -0.090000 11:14:38 Stage Position Measurement, pos = -0.090000 m 11:14:40 Magnet Current, Imag = 150.0539 A Vtrans = 1.500539 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:14:40 Hall Probe Field Measurement, B = -0.140840 T 11:14:48 Move Stage, position = -0.080000 11:14:49 Stage Position Measurement, pos = -0.080000 m 11:14:50 Magnet Current, Imag = 150.0419 A Vtrans = 1.500419 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:14:51 Hall Probe Field Measurement, B = -0.171820 T 11:14:58 Move Stage, position = -0.070000 11:14:59 Stage Position Measurement, pos = -0.070000 m 11:15:01 Magnet Current, Imag = 150.0278 A Vtrans = 1.500278 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:15:01 Hall Probe Field Measurement, B = -0.192550 T 11:15:09 Move Stage, position = -0.060000 11:15:10 Stage Position Measurement, pos = -0.060000 m 11:15:11 Magnet Current, Imag = 150.0721 A Vtrans = 1.500721 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:15:12 Hall Probe Field Measurement, B = -0.205730 T 11:15:19 Move Stage, position = -0.050000 11:15:20 Stage Position Measurement, pos = -0.050000 m 11:15:21 Magnet Current, Imag = 150.0495 A Vtrans = 1.500495 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:15:22 Hall Probe Field Measurement, B = -0.213470 T 11:15:30 Move Stage, position = -0.040000 11:15:31 Stage Position Measurement, pos = -0.040000 m 11:15:32 Magnet Current, Imag = 150.0522 A Vtrans = 1.500522 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:15:32 Hall Probe Field Measurement, B = -0.218170 T 11:15:40 Move Stage, position = -0.030000 11:15:41 Stage Position Measurement, pos = -0.030000 m 11:15:42 Magnet Current, Imag = 150.0430 A Vtrans = 1.500430 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:15:43 Hall Probe Field Measurement, B = -0.220840 T 11:15:51 Move Stage, position = -0.020000 11:15:52 Stage Position Measurement, pos = -0.020000 m 11:15:53 Magnet Current, Imag = 150.0492 A Vtrans = 1.500492 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:15:53 Hall Probe Field Measurement, B = -0.222440 T 11:16:01 Move Stage, position = -0.010000 11:16:02 Stage Position Measurement, pos = -0.010000 m 11:16:03 Magnet Current, Imag = 150.0527 A Vtrans = 1.500527 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:16:04 Hall Probe Field Measurement, B = -0.223380 T 11:16:12 Move Stage, position = 0.000000 11:16:13 Stage Position Measurement, pos = 0.000000 m 11:16:14 Magnet Current, Imag = 150.0399 A Vtrans = 1.500399 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:16:14 Hall Probe Field Measurement, B = -0.223680 T 11:16:22 Move Stage, position = 0.010000 11:16:23 Stage Position Measurement, pos = 0.010000 m 11:16:24 Magnet Current, Imag = 150.0471 A Vtrans = 1.500471 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:16:25 Hall Probe Field Measurement, B = -0.223670 T 11:16:32 Move Stage, position = 0.020000 11:16:33 Stage Position Measurement, pos = 0.020000 m 11:16:35 Magnet Current, Imag = 150.0379 A Vtrans = 1.500379 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:16:35 Hall Probe Field Measurement, B = -0.222920 T 11:16:43 Move Stage, position = 0.030000 11:16:44 Stage Position Measurement, pos = 0.030000 m 11:16:45 Magnet Current, Imag = 150.0386 A Vtrans = 1.500386 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:16:46 Hall Probe Field Measurement, B = -0.221550 T 11:16:53 Move Stage, position = 0.040000 11:16:54 Stage Position Measurement, pos = 0.040000 m 11:16:56 Magnet Current, Imag = 150.0395 A Vtrans = 1.500395 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:16:56 Hall Probe Field Measurement, B = -0.218820 T 11:17:04 Move Stage, position = 0.050000 11:17:05 Stage Position Measurement, pos = 0.050000 m 11:17:06 Magnet Current, Imag = 150.0212 A Vtrans = 1.500212 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:17:07 Hall Probe Field Measurement, B = -0.213900 T 11:17:14 Move Stage, position = 0.060000 11:17:15 Stage Position Measurement, pos = 0.060000 m 11:17:17 Magnet Current, Imag = 150.0401 A Vtrans = 1.500401 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:17:17 Hall Probe Field Measurement, B = -0.205580 T 11:17:25 Move Stage, position = 0.070000 11:17:26 Stage Position Measurement, pos = 0.070000 m 11:17:27 Magnet Current, Imag = 150.0440 A Vtrans = 1.500440 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:17:28 Hall Probe Field Measurement, B = -0.191320 T 11:17:35 Move Stage, position = 0.080000 11:17:36 Stage Position Measurement, pos = 0.080000 m 11:17:38 Magnet Current, Imag = 150.0338 A Vtrans = 1.500338 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:17:38 Hall Probe Field Measurement, B = -0.168750 T 11:17:46 Move Stage, position = 0.090000 11:17:47 Stage Position Measurement, pos = 0.090000 m 11:17:48 Magnet Current, Imag = 150.0357 A Vtrans = 1.500357 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:17:49 Hall Probe Field Measurement, B = -0.136300 T 11:17:56 Move Stage, position = 0.100000 11:17:57 Stage Position Measurement, pos = 0.100000 m 11:17:59 Magnet Current, Imag = 150.0504 A Vtrans = 1.500504 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:17:59 Hall Probe Field Measurement, B = -0.096810 T 11:18:07 Move Stage, position = 0.110000 11:18:08 Stage Position Measurement, pos = 0.110000 m 11:18:09 Magnet Current, Imag = 150.0587 A Vtrans = 1.500587 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:18:10 Hall Probe Field Measurement, B = -0.061090 T 11:18:17 Move Stage, position = 0.120000 11:18:18 Stage Position Measurement, pos = 0.120000 m 11:18:20 Magnet Current, Imag = 150.0544 A Vtrans = 1.500544 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:18:20 Hall Probe Field Measurement, B = -0.035800 T 11:18:28 Move Stage, position = 0.130000 11:18:29 Stage Position Measurement, pos = 0.130000 m 11:18:30 Magnet Current, Imag = 150.0534 A Vtrans = 1.500534 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:18:31 Hall Probe Field Measurement, B = -0.020690 T 11:18:38 Move Stage, position = 0.140000 11:18:39 Stage Position Measurement, pos = 0.140000 m 11:18:40 Magnet Current, Imag = 150.0474 A Vtrans = 1.500474 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:18:41 Hall Probe Field Measurement, B = -0.012300 T 11:18:49 Move Stage, position = 0.150000 11:18:50 Stage Position Measurement, pos = 0.150000 m 11:18:51 Magnet Current, Imag = 150.0441 A Vtrans = 1.500441 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:18:51 Hall Probe Field Measurement, B = -0.007670 T 11:18:59 Move Stage, position = 0.160000 11:19:00 Stage Position Measurement, pos = 0.160000 m 11:19:01 Magnet Current, Imag = 150.0311 A Vtrans = 1.500311 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:19:02 Hall Probe Field Measurement, B = -0.005020 T 11:19:10 Move Stage, position = 0.170000 11:19:11 Stage Position Measurement, pos = 0.170000 m 11:19:12 Magnet Current, Imag = 150.0356 A Vtrans = 1.500356 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:19:12 Hall Probe Field Measurement, B = -0.003460 T 11:19:20 Move Stage, position = 0.180000 11:19:21 Stage Position Measurement, pos = 0.180000 m 11:19:22 Magnet Current, Imag = 150.0493 A Vtrans = 1.500493 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:19:23 Hall Probe Field Measurement, B = -0.002490 T 11:19:30 Move Stage, position = 0.190000 11:19:32 Stage Position Measurement, pos = 0.190000 m 11:19:33 Magnet Current, Imag = 150.0495 A Vtrans = 1.500495 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:19:34 Hall Probe Field Measurement, B = -0.001870 T 11:19:42 Move Stage, position = 0.200000 11:19:43 Stage Position Measurement, pos = 0.200000 m 11:19:44 Magnet Current, Imag = 150.0476 A Vtrans = 1.500476 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:19:45 Hall Probe Field Measurement, B = -0.001450 T 11:19:52 Move Stage, position = 0.210000 11:19:53 Stage Position Measurement, pos = 0.210000 m 11:19:55 Magnet Current, Imag = 150.0486 A Vtrans = 1.500486 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:19:55 Hall Probe Field Measurement, B = -0.001160 T 11:20:03 Move Stage, position = 0.220000 11:20:04 Stage Position Measurement, pos = 0.220000 m 11:20:05 Magnet Current, Imag = 150.0349 A Vtrans = 1.500349 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:20:06 Hall Probe Field Measurement, B = -0.000960 T 11:20:13 Move Stage, position = 0.230000 11:20:14 Stage Position Measurement, pos = 0.230000 m 11:20:16 Magnet Current, Imag = 150.0454 A Vtrans = 1.500454 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:20:16 Hall Probe Field Measurement, B = -0.000800 T 11:20:24 Move Stage, position = 0.240000 11:20:25 Stage Position Measurement, pos = 0.240000 m 11:20:26 Magnet Current, Imag = 150.0372 A Vtrans = 1.500372 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:20:27 Hall Probe Field Measurement, B = -0.000690 T 11:20:34 Move Stage, position = 0.250000 11:20:35 Stage Position Measurement, pos = 0.250000 m 11:20:36 Magnet Current, Imag = 150.0335 A Vtrans = 1.500335 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 11:20:37 Hall Probe Field Measurement, B = -0.000580 T 11:21:33 Move Stage, position = 0.000000 11:21:33 Magnet current ramping to 0.0000 A...