SLAC Magnetic Measurements
Date: 12-12-1996
Time: 16:09:32

Project: SLC
Magnet Type: DIPOLE
Magnet Name (Serial #): NDRINJ
Bar Code Number: 1
Test Stand: CLEAN ROOM
Measurement System: B9900 ULTRA MIDGET HALL PROBE.
Operator: tss
Run Number: 18
Comment: By vs x, Z = 8.0(in), Y = -0.400(in), backleg = 4.5(A), Memo ref: 6bvi.

Standardization Currents
 2  cycles, 0 to  375  to 0 A
16:10:01  Probe moved to Z =  .2  cm
16:10:01  Field Measurement, B =  .00014  T
16:10:20  Probe moved to Z =  .3  cm
16:10:20  Field Measurement, B =  .00014  T
16:10:29  Probe moved to Z =  .4  cm
16:10:29  Field Measurement, B =  .00014  T
16:10:36  Probe moved to Z =  .5  cm
16:10:36  Field Measurement, B =  .00011  T
16:10:43  Probe moved to Z =  .6  cm
16:10:43  Field Measurement, B =  .00018  T
16:10:50  Probe moved to Z =  .7  cm
16:10:50  Field Measurement, B =  .00021  T
16:10:56  Probe moved to Z =  .8  cm
16:10:56  Field Measurement, B =  .00014  T
16:11:03  Probe moved to Z =  .9  cm
16:11:04  Field Measurement, B =  .00011  T
16:11:11  Probe moved to Z =  1  cm
16:11:11  Field Measurement, B =  .00011  T
16:11:11  Integrated Field Strength BL =  1.155E-06  Tm
16:11:31  Probe moved to Z =  0  cm