SLAC Magnetic Measurements
Date: 12-11-1996
Time: 20:17:37

Project: SLC
Magnet Type: DIPOLE
Magnet Name (Serial #): NDRINJ
Bar Code Number: 1
Test Stand: CLEAN ROOM
Measurement System: B9900 ULTRA MIDGET HALL PROBE.
Operator: tss
Run Number: 15
Comment: By vs x, Z = 4.0(in), Y = 0.000(in), backleg = 4.5(A), Memo ref: 6bv.

Standardization Currents
 2  cycles, 0 to  375  to 0 A
20:18:22  Probe moved to Z =  0  cm
20:18:22  Field Measurement, B = -.0007  T
20:18:32  Probe moved to Z =  .025  cm
20:18:32  Field Measurement, B = -.0003  T
20:18:44  Probe moved to Z =  .05  cm
20:18:44  Field Measurement, B = -.00003  T
20:18:52  Probe moved to Z =  .075  cm
20:18:53  Field Measurement, B =  .00011  T
20:19:00  Probe moved to Z =  .1  cm
20:19:01  Field Measurement, B =  .00019  T
20:19:13  Probe moved to Z =  .2  cm
20:19:14  Field Measurement, B =  .00027  T
20:19:25  Probe moved to Z =  .3  cm
20:19:25  Field Measurement, B =  .00024  T
20:19:32  Probe moved to Z =  .4  cm
20:19:32  Field Measurement, B =  .00021  T
20:19:41  Probe moved to Z =  .5  cm
20:19:41  Field Measurement, B =  .00018  T
20:19:50  Probe moved to Z =  .6  cm
20:19:51  Field Measurement, B =  .00016  T
20:19:57  Probe moved to Z =  .7  cm
20:19:58  Field Measurement, B =  .00014  T
20:20:04  Probe moved to Z =  .8  cm
20:20:04  Field Measurement, B =  .00013  T
20:20:09  Probe moved to Z =  .9  cm
20:20:10  Field Measurement, B =  .00013  T
20:20:17  Probe moved to Z =  1  cm
20:20:17  Field Measurement, B =  .00011  T
20:20:17  Integrated Field Strength BL =  1.49125E-06  Tm
20:20:19  Probe moved to Z =  0  cm