SLAC Magnetic Measurements
Date: 12-11-1996
Time: 20:11:46

Project: SLC
Magnet Type: DIPOLE
Magnet Name (Serial #): NDRINJ
Bar Code Number: 1
Test Stand: CLEAN ROOM
Measurement System: B9900 ULTRA MIDGET HALL PROBE.
Operator: tss
Run Number: 14
Comment: By vs x, Z = 4.0(in), Y = 0.000(in), backleg = 9.0(A), Memo ref: 6biii.

Standardization Currents
 2  cycles, 0 to  375  to 0 A
20:12:15  Probe moved to Z =  0  cm
20:12:15  Field Measurement, B = -.00031  T
20:12:29  Probe moved to Z =  .025  cm
20:12:30  Field Measurement, B =  .0001  T
20:12:42  Probe moved to Z =  .05  cm
20:12:42  Field Measurement, B =  .00031  T
20:12:51  Probe moved to Z =  .075  cm
20:12:51  Field Measurement, B =  .00044  T
20:13:02  Probe moved to Z =  .1  cm
20:13:02  Field Measurement, B =  .00048  T
20:13:18  Probe moved to Z =  .2  cm
20:13:18  Field Measurement, B =  .0005  T
20:13:28  Probe moved to Z =  .3  cm
20:13:28  Field Measurement, B =  .0004  T
20:13:38  Probe moved to Z =  .4  cm
20:13:38  Field Measurement, B =  .00034  T
20:14:04  Probe moved to Z =  .5  cm
20:14:04  Field Measurement, B =  .00029  T
20:14:22  Probe moved to Z =  .6  cm
20:14:22  Field Measurement, B =  .00024  T
20:14:28  Probe moved to Z =  .7  cm
20:14:28  Field Measurement, B =  .00021  T
20:14:34  Probe moved to Z =  .8  cm
20:14:34  Field Measurement, B =  .00019  T
20:14:39  Probe moved to Z =  .9  cm
20:14:39  Field Measurement, B =  .00018  T
20:14:46  Probe moved to Z =  1  cm
20:14:46  Field Measurement, B =  .00016  T
20:14:47  Integrated Field Strength BL =  2.90375E-06  Tm
20:14:50  Probe moved to Z =  0  cm