SLAC Magnetic Measurements
Date: 12-11-1996
Time: 20:05:35

Project: SLC
Magnet Type: DIPOLE
Magnet Name (Serial #): NDRINJ
Bar Code Number: 1
Test Stand: CLEAN ROOM
Measurement System: B9900 ULTRA MIDGET HALL PROBE.
Operator: tss
Run Number: 13
Comment: By vs x, Z = 4.0(in), Y = 0.000(in), backleg = 0.0(A), Memo ref: 6bi.

Standardization Currents
 2  cycles, 0 to  375  to 0 A
20:06:06  Probe moved to Z =  0  cm
20:06:06  Field Measurement, B = -.0011  T
20:06:21  Probe moved to Z =  .025  cm
20:06:21  Field Measurement, B = -.00067  T
20:06:36  Probe moved to Z =  .05  cm
20:06:36  Field Measurement, B = -.00039  T
20:06:44  Probe moved to Z =  .075  cm
20:06:44  Field Measurement, B = -.0002  T
20:06:52  Probe moved to Z =  .1  cm
20:06:53  Field Measurement, B = -.0001  T
20:07:05  Probe moved to Z =  .2  cm
20:07:05  Field Measurement, B =  .00005  T
20:07:16  Probe moved to Z =  .3  cm
20:07:17  Field Measurement, B =  .00008  T
20:07:24  Probe moved to Z =  .4  cm
20:07:24  Field Measurement, B =  .00008  T
20:07:39  Probe moved to Z =  .5  cm
20:07:39  Field Measurement, B =  .00008  T
20:07:53  Probe moved to Z =  .6  cm
20:07:54  Field Measurement, B =  .00006  T
20:08:00  Probe moved to Z =  .7  cm
20:08:01  Field Measurement, B =  .00006  T
20:08:07  Probe moved to Z =  .8  cm
20:08:07  Field Measurement, B =  .00006  T
20:08:17  Probe moved to Z =  .9  cm
20:08:17  Field Measurement, B =  .00006  T
20:08:26  Probe moved to Z =  1  cm
20:08:26  Field Measurement, B =  .00006  T
20:08:26  Integrated Field Strength BL =  4.499998E-08  Tm
20:08:26  Probe moved to Z =  0  cm