SLAC Magnetic Measurements
Date: 12-11-1996
Time: 19:36:26

Project: SLC
Magnet Type: DIPOLE
Magnet Name (Serial #): NDRINJ
Bar Code Number: 1
Test Stand: CLEAN ROOM
Measurement System: B9900 ULTRA MIDGET HALL PROBE.
Operator: tss
Run Number: 12
Comment: By vs x, Z = 8.0(in), Y = 0.000(in), backleg = 4.5(A), Memo ref: 6bv.

Standardization Currents
 2  cycles, 0 to  375  to 0 A
19:37:01  Probe moved to Z =  0  cm
19:37:02  Field Measurement, B = -.00031  T
19:37:17  Probe moved to Z =  .025  cm
19:37:17  Field Measurement, B = -.0001  T
19:37:27  Probe moved to Z =  .05  cm
19:37:27  Field Measurement, B =  .00005  T
19:37:32  Probe moved to Z =  .075  cm
19:37:32  Field Measurement, B =  .00014  T
19:37:38  Probe moved to Z =  .1  cm
19:37:38  Field Measurement, B =  .00019  T
19:37:47  Probe moved to Z =  .2  cm
19:37:47  Field Measurement, B =  .00026  T
19:37:59  Probe moved to Z =  .3  cm
19:38:00  Field Measurement, B =  .00023  T
19:38:08  Probe moved to Z =  .4  cm
19:38:09  Field Measurement, B =  .00019  T
19:38:37  Probe moved to Z =  .5  cm
19:38:37  Field Measurement, B =  .00018  T
19:38:50  Probe moved to Z =  .6  cm
19:38:50  Field Measurement, B =  .00016  T
19:39:00  Probe moved to Z =  .7  cm
19:39:01  Field Measurement, B =  .00014  T
19:39:09  Probe moved to Z =  .8  cm
19:39:09  Field Measurement, B =  .00013  T
19:39:17  Probe moved to Z =  .9  cm
19:39:17  Field Measurement, B =  .00011  T
19:39:27  Probe moved to Z =  1  cm
19:39:27  Field Measurement, B =  .00011  T
19:39:27  Integrated Field Strength BL =  1.5575E-06  Tm
19:39:39  Probe moved to Z =  0  cm