SLAC Magnetic Measurements Date: 03-04-2003 Time: 16:08:20 Project: PEPII Magnet Type: Quad Magnet Name: Q58Cu4 Serial Number: Run Number: 3 Measurement Device: 10 wire Operator: sa Comment:Quad with dipole adjacent. Spacing is 24.43" ctr to ctr. Quad powered only Standardization: 3 cycles from 10.0 A to 160.0 A to 10.0 A Test Currents (A): 122.0 122.0 122.0 16:08:25 Initial Zero Current Measurement, Imag_zero = 0.0000 A 16:08:25 Magnet current ramping to 10.0000 A... 16:09:22 Magnet current ramping to 160.0000 A... 16:10:51 Magnet current ramping to 10.0000 A... 16:12:19 Magnet current ramping to 160.0000 A... 16:13:48 Magnet current ramping to 10.0000 A... 16:15:16 Magnet current ramping to 160.0000 A... 16:16:45 Magnet current ramping to 10.0000 A... 16:18:14 Magnet current ramping to 122.0000 A... 16:19:51 Magnet Current, Imag = 121.8539 A Vtrans = 1.218539 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:19:52 Magnet Current, Imag = 121.8503 A Vtrans = 1.218503 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:19:53 Magnet Current, Imag = 121.8560 A Vtrans = 1.218560 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:19:55 Magnet Current, Imag = 121.8522 A Vtrans = 1.218522 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:19:55 Magnet Current Measurement: Imag = 121.8531 +- 0.0021 A 16:19:55 Magnetic Field Measurement Measuring the magnet strength... 16:19:55 Integrated Voltage Measurement... 16:20:15 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.005769421 Vs 16:20:25 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.005675271 Vs 16:20:35 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.005787837 Vs 16:20:45 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.005689747 Vs 16:20:56 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.005755354 Vs 16:21:06 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.005690107 Vs 16:21:16 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.005750272 Vs 16:21:26 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.005690270 Vs 16:21:26 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.005726035 +- 0.000007425 Vs 16:21:26 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.005726035 +- 0.000007425 Vs BL = -0.05726035 +- 0.00007425 Tm 16:21:26 Integrated Voltage Measurement... 16:21:41 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0100000 m VT = -0.004181470 Vs 16:21:52 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0100000 m VT = 0.004117435 Vs 16:22:02 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0100000 m VT = -0.004194902 Vs 16:22:12 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0100000 m VT = 0.004112809 Vs 16:22:22 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0100000 m VT = -0.004188327 Vs 16:22:32 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0100000 m VT = 0.004112059 Vs 16:22:43 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0100000 m VT = -0.004194967 Vs 16:22:53 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0100000 m VT = 0.004106623 Vs 16:22:53 Integrated Voltage Average and RMS of Measurements X0 = -0.0150000 m, Delta X = 0.0100000 m VT = -0.004151074 +- 0.000001675 Vs 16:22:53 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0150000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.004151074 +- 0.000001675 Vs BL = -0.04151074 +- 0.00001675 Tm 16:22:53 Integrated Voltage Measurement... 16:23:08 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.002631352 Vs 16:23:18 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.002531064 Vs 16:23:28 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.002629416 Vs 16:23:39 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.002535505 Vs 16:23:49 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.002636484 Vs 16:23:59 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.002530181 Vs 16:24:09 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.002633033 Vs 16:24:20 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.002528686 Vs 16:24:20 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.002581965 +- 0.000000989 Vs 16:24:20 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002581965 +- 0.000000989 Vs BL = -0.02581965 +- 0.00000989 Tm 16:24:20 Integrated Voltage Measurement... 16:24:35 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0100000 m VT = -0.001069125 Vs 16:24:45 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0100000 m VT = 0.000953897 Vs 16:24:55 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0100000 m VT = -0.001070819 Vs 16:25:05 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0100000 m VT = 0.000947519 Vs 16:25:16 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0100000 m VT = -0.001071847 Vs 16:25:26 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0100000 m VT = 0.000948364 Vs 16:25:36 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0100000 m VT = -0.001075276 Vs 16:25:46 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0100000 m VT = 0.000950679 Vs 16:25:46 Integrated Voltage Average and RMS of Measurements X0 = -0.0050000 m, Delta X = 0.0100000 m VT = -0.001010941 +- 0.000001441 Vs 16:25:46 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0050000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001010941 +- 0.000001441 Vs BL = -0.01010941 +- 0.00001441 Tm 16:25:46 Integrated Voltage Measurement... 16:26:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000500558 Vs 16:26:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000616484 Vs 16:26:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000503978 Vs 16:26:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000612730 Vs 16:26:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000505869 Vs 16:26:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000619823 Vs 16:27:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000503085 Vs 16:27:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000616729 Vs 16:27:13 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000559907 +- 0.000001801 Vs 16:27:13 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000559907 +- 0.000001801 Vs BL = 0.00559907 +- 0.00001801 Tm 16:27:13 Integrated Voltage Measurement... 16:27:28 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0100000 m VT = 0.002065326 Vs 16:27:38 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0100000 m VT = -0.002197740 Vs 16:27:49 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0100000 m VT = 0.002069995 Vs 16:27:59 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0100000 m VT = -0.002193037 Vs 16:28:09 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0100000 m VT = 0.002074407 Vs 16:28:19 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0100000 m VT = -0.002181100 Vs 16:28:29 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0100000 m VT = 0.002074635 Vs 16:28:40 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0100000 m VT = -0.002186862 Vs 16:28:40 Integrated Voltage Average and RMS of Measurements X0 = 0.0050000 m, Delta X = 0.0100000 m VT = 0.002130388 +- 0.000001554 Vs 16:28:40 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0050000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.002130388 +- 0.000001554 Vs BL = 0.02130388 +- 0.00001554 Tm 16:28:40 Integrated Voltage Measurement... 16:28:55 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.003629861 Vs 16:29:05 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.003762024 Vs 16:29:15 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.003639616 Vs 16:29:26 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.003759607 Vs 16:29:36 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.003637586 Vs 16:29:46 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.003764939 Vs 16:29:56 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.003640237 Vs 16:30:06 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.003754615 Vs 16:30:06 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.003698561 +- 0.000002034 Vs 16:30:06 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.003698561 +- 0.000002034 Vs BL = 0.03698561 +- 0.00002034 Tm 16:30:06 Integrated Voltage Measurement... 16:30:22 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0100000 m VT = 0.005212479 Vs 16:30:32 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0100000 m VT = -0.005318635 Vs 16:30:42 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0100000 m VT = 0.005213272 Vs 16:30:53 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0100000 m VT = -0.005327020 Vs 16:31:03 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0100000 m VT = 0.005209437 Vs 16:31:13 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0100000 m VT = -0.005324151 Vs 16:31:23 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0100000 m VT = 0.005214258 Vs 16:31:33 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0100000 m VT = -0.005327007 Vs 16:31:33 Integrated Voltage Average and RMS of Measurements X0 = 0.0150000 m, Delta X = 0.0100000 m VT = 0.005268282 +- 0.000002159 Vs 16:31:33 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0150000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.005268282 +- 0.000002159 Vs BL = 0.05268282 +- 0.00002159 Tm 16:31:33 Integrated Voltage Measurement... 16:31:48 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.006771454 Vs 16:31:59 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.006900570 Vs 16:32:09 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.006770818 Vs 16:32:19 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.006904242 Vs 16:32:29 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.006773595 Vs 16:32:40 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.006901480 Vs 16:32:50 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.006772151 Vs 16:33:00 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.006912123 Vs 16:33:00 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.006838304 +- 0.000002298 Vs 16:33:00 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.006838304 +- 0.000002298 Vs BL = 0.06838304 +- 0.00002298 Tm 16:33:08 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00558 0.00001 1 3.14059 0.00108 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- -0.020000 -0.05726 0.00007 -0.05723 -0.00003 -0.015000 -0.04151 0.00002 -0.04153 0.00001 -0.010000 -0.02582 0.00001 -0.02582 0.00000 -0.005000 -0.01011 0.00001 -0.01012 0.00001 0.000000 0.00560 0.00002 0.00558 0.00002 0.005000 0.02130 0.00002 0.02129 0.00002 0.010000 0.03699 0.00002 0.03699 -0.00000 0.015000 0.05268 0.00002 0.05269 -0.00001 0.020000 0.06838 0.00002 0.06840 -0.00001 16:33:08 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 9 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0200 -0.05726 0.00007 -0.0150 -0.04151 0.00002 -0.0100 -0.02582 0.00001 -0.0050 -0.01011 0.00001 0.0000 0.00560 0.00002 0.0050 0.02130 0.00002 0.0100 0.03699 0.00002 0.0150 0.05268 0.00002 0.0200 0.06838 0.00002 SL = 3.1405935 +- 0.0010845 Tm^2/m^n 16:33:08 Quadrupole Strength Calculation Check Slope = 3.140594 Tm/m, Inter = 0.005584 Tm, Sig_slope = 0.000452 Tm/m, Est_sig = 0.000018 Tm GL = 3.140594 +- 0.000452 T 16:33:08 Magnet Strength Measurement Harmonic Number = 2 SL = 3.1405935 +- 0.0010845 Tm^2/m^n 16:33:10 Magnet Current, Imag = 121.8557 A Vtrans = 1.218557 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:33:11 Magnet Current, Imag = 121.8513 A Vtrans = 1.218513 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:33:12 Magnet Current, Imag = 121.8601 A Vtrans = 1.218601 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:33:13 Magnet Current, Imag = 121.8585 A Vtrans = 1.218585 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:33:13 Magnet Current Measurement: Imag = 121.8564 +- 0.0033 A 16:33:14 Magnet current ramping to 122.0000 A... 16:33:46 Magnet Current, Imag = 121.8499 A Vtrans = 1.218499 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:33:47 Magnet Current, Imag = 121.8598 A Vtrans = 1.218598 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:33:49 Magnet Current, Imag = 121.8589 A Vtrans = 1.218589 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:33:51 Magnet Current, Imag = 121.8549 A Vtrans = 1.218549 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:33:51 Magnet Current Measurement: Imag = 121.8559 +- 0.0039 A 16:33:51 Magnetic Field Measurement Measuring the magnet strength... 16:33:51 Integrated Voltage Measurement... 16:34:11 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.005798220 Vs 16:34:21 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.005647625 Vs 16:34:31 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.005801869 Vs 16:34:42 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.005647961 Vs 16:34:52 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.005803063 Vs 16:35:02 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.005650765 Vs 16:35:12 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.005803659 Vs 16:35:22 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.005646106 Vs 16:35:22 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.005724908 +- 0.000001411 Vs 16:35:23 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.005724908 +- 0.000001411 Vs BL = -0.05724908 +- 0.00001411 Tm 16:35:23 Integrated Voltage Measurement... 16:35:38 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0100000 m VT = -0.004230056 Vs 16:35:48 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0100000 m VT = 0.004072591 Vs 16:35:58 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0100000 m VT = -0.004225643 Vs 16:36:08 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0100000 m VT = 0.004073935 Vs 16:36:19 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0100000 m VT = -0.004225369 Vs 16:36:29 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0100000 m VT = 0.004083049 Vs 16:36:39 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0100000 m VT = -0.004224524 Vs 16:36:49 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0100000 m VT = 0.004080069 Vs 16:36:49 Integrated Voltage Average and RMS of Measurements X0 = -0.0150000 m, Delta X = 0.0100000 m VT = -0.004151904 +- 0.000001603 Vs 16:36:49 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0150000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.004151904 +- 0.000001603 Vs BL = -0.04151904 +- 0.00001603 Tm 16:36:50 Integrated Voltage Measurement... 16:37:05 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.002657847 Vs 16:37:15 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.002514290 Vs 16:37:25 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.002658740 Vs 16:37:35 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.002510719 Vs 16:37:45 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.002642658 Vs 16:37:56 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.002517528 Vs 16:38:06 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.002641828 Vs 16:38:16 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.002519523 Vs 16:38:16 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.002582892 +- 0.000002560 Vs 16:38:16 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002582892 +- 0.000002560 Vs BL = -0.02582892 +- 0.00002560 Tm 16:38:16 Integrated Voltage Measurement... 16:38:31 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0100000 m VT = -0.001071090 Vs 16:38:42 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0100000 m VT = 0.000948662 Vs 16:38:52 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0100000 m VT = -0.001076796 Vs 16:39:02 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0100000 m VT = 0.000945850 Vs 16:39:12 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0100000 m VT = -0.001079012 Vs 16:39:22 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0100000 m VT = 0.000947690 Vs 16:39:33 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0100000 m VT = -0.001070686 Vs 16:39:43 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0100000 m VT = 0.000946176 Vs 16:39:43 Integrated Voltage Average and RMS of Measurements X0 = -0.0050000 m, Delta X = 0.0100000 m VT = -0.001010745 +- 0.000001819 Vs 16:39:43 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0050000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001010745 +- 0.000001819 Vs BL = -0.01010745 +- 0.00001819 Tm 16:39:43 Integrated Voltage Measurement... 16:39:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000498674 Vs 16:40:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000616280 Vs 16:40:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000493119 Vs 16:40:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000618275 Vs 16:40:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000496187 Vs 16:40:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000622243 Vs 16:41:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000500398 Vs 16:41:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000618770 Vs 16:41:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000557993 +- 0.000001546 Vs 16:41:10 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000557993 +- 0.000001546 Vs BL = 0.00557993 +- 0.00001546 Tm 16:41:10 Integrated Voltage Measurement... 16:41:25 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0100000 m VT = 0.002070138 Vs 16:41:36 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0100000 m VT = -0.002182765 Vs 16:41:46 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0100000 m VT = 0.002073827 Vs 16:41:56 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0100000 m VT = -0.002184467 Vs 16:42:06 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0100000 m VT = 0.002068956 Vs 16:42:16 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0100000 m VT = -0.002188229 Vs 16:42:27 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0100000 m VT = 0.002065717 Vs 16:42:37 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0100000 m VT = -0.002193932 Vs 16:42:37 Integrated Voltage Average and RMS of Measurements X0 = 0.0050000 m, Delta X = 0.0100000 m VT = 0.002128504 +- 0.000001263 Vs 16:42:37 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0050000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.002128504 +- 0.000001263 Vs BL = 0.02128504 +- 0.00001263 Tm 16:42:37 Integrated Voltage Measurement... 16:42:52 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.003625686 Vs 16:43:02 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.003772298 Vs 16:43:13 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.003623720 Vs 16:43:23 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.003768946 Vs 16:43:33 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.003634406 Vs 16:43:43 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.003770586 Vs 16:43:53 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.003625801 Vs 16:44:04 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.003770217 Vs 16:44:04 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.003698958 +- 0.000002253 Vs 16:44:04 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.003698958 +- 0.000002253 Vs BL = 0.03698958 +- 0.00002253 Tm 16:44:04 Integrated Voltage Measurement... 16:44:19 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0100000 m VT = 0.005195435 Vs 16:44:29 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0100000 m VT = -0.005340500 Vs 16:44:39 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0100000 m VT = 0.005191553 Vs 16:44:50 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0100000 m VT = -0.005347074 Vs 16:45:00 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0100000 m VT = 0.005185123 Vs 16:45:10 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0100000 m VT = -0.005349022 Vs 16:45:20 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0100000 m VT = 0.005191983 Vs 16:45:30 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0100000 m VT = -0.005347545 Vs 16:45:30 Integrated Voltage Average and RMS of Measurements X0 = 0.0150000 m, Delta X = 0.0100000 m VT = 0.005268529 +- 0.000001070 Vs 16:45:30 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0150000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.005268529 +- 0.000001070 Vs BL = 0.05268529 +- 0.00001070 Tm 16:45:30 Integrated Voltage Measurement... 16:45:46 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.006758149 Vs 16:45:56 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.006919585 Vs 16:46:06 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.006757156 Vs 16:46:16 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.006926244 Vs 16:46:26 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.006760091 Vs 16:46:37 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.006911582 Vs 16:46:47 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.006768306 Vs 16:46:57 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.006918335 Vs 16:46:57 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.006839931 +- 0.000002851 Vs 16:46:57 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.006839931 +- 0.000002851 Vs BL = 0.06839931 +- 0.00002851 Tm 16:47:05 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00558 0.00001 1 3.14079 0.00052 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- -0.020000 -0.05725 0.00001 -0.05723 -0.00001 -0.015000 -0.04152 0.00002 -0.04153 0.00001 -0.010000 -0.02583 0.00003 -0.02583 -0.00000 -0.005000 -0.01011 0.00002 -0.01012 0.00001 0.000000 0.00558 0.00002 0.00558 -0.00000 0.005000 0.02129 0.00001 0.02129 -0.00000 0.010000 0.03699 0.00002 0.03699 0.00000 0.015000 0.05269 0.00001 0.05269 -0.00001 0.020000 0.06840 0.00003 0.06840 0.00000 16:47:05 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 9 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0200 -0.05725 0.00001 -0.0150 -0.04152 0.00002 -0.0100 -0.02583 0.00003 -0.0050 -0.01011 0.00002 0.0000 0.00558 0.00002 0.0050 0.02129 0.00001 0.0100 0.03699 0.00002 0.0150 0.05269 0.00001 0.0200 0.06840 0.00003 SL = 3.1407869 +- 0.0005236 Tm^2/m^n 16:47:05 Quadrupole Strength Calculation Check Slope = 3.140787 Tm/m, Inter = 0.005582 Tm, Sig_slope = 0.000249 Tm/m, Est_sig = 0.000010 Tm GL = 3.140787 +- 0.000249 T 16:47:05 Magnet Strength Measurement Harmonic Number = 2 SL = 3.1407869 +- 0.0005236 Tm^2/m^n 16:47:06 Magnet Current, Imag = 121.8637 A Vtrans = 1.218637 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:47:08 Magnet Current, Imag = 121.8589 A Vtrans = 1.218589 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:47:09 Magnet Current, Imag = 121.8615 A Vtrans = 1.218615 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:47:10 Magnet Current, Imag = 121.8604 A Vtrans = 1.218604 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:47:10 Magnet Current Measurement: Imag = 121.8611 +- 0.0017 A 16:47:10 Magnet current ramping to 122.0000 A... 16:47:43 Magnet Current, Imag = 121.8508 A Vtrans = 1.218508 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:47:44 Magnet Current, Imag = 121.8686 A Vtrans = 1.218686 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:47:46 Magnet Current, Imag = 121.8520 A Vtrans = 1.218520 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:47:47 Magnet Current, Imag = 121.8544 A Vtrans = 1.218544 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:47:47 Magnet Current Measurement: Imag = 121.8564 +- 0.0071 A 16:47:47 Magnetic Field Measurement Measuring the magnet strength... 16:47:47 Integrated Voltage Measurement... 16:48:07 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.005787211 Vs 16:48:17 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.005664290 Vs 16:48:28 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.005790922 Vs 16:48:38 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.005663279 Vs 16:48:48 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.005788210 Vs 16:48:58 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.005657731 Vs 16:49:08 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.005793156 Vs 16:49:19 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.005655598 Vs 16:49:19 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.005725050 +- 0.000001539 Vs 16:49:19 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.005725050 +- 0.000001539 Vs BL = -0.05725050 +- 0.00001539 Tm 16:49:19 Integrated Voltage Measurement... 16:49:34 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0100000 m VT = -0.004228454 Vs 16:49:44 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0100000 m VT = 0.004081177 Vs 16:49:54 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0100000 m VT = -0.004219665 Vs 16:50:04 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0100000 m VT = 0.004084308 Vs 16:50:15 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0100000 m VT = -0.004225706 Vs 16:50:25 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0100000 m VT = 0.004074119 Vs 16:50:35 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0100000 m VT = -0.004225049 Vs 16:50:45 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0100000 m VT = 0.004079408 Vs 16:50:45 Integrated Voltage Average and RMS of Measurements X0 = -0.0150000 m, Delta X = 0.0100000 m VT = -0.004152236 +- 0.000001740 Vs 16:50:45 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0150000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.004152236 +- 0.000001740 Vs BL = -0.04152236 +- 0.00001740 Tm 16:50:45 Integrated Voltage Measurement... 16:51:01 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.002665667 Vs 16:51:11 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.002501523 Vs 16:51:21 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.002662145 Vs 16:51:32 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.002507408 Vs 16:51:42 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.002655360 Vs 16:51:52 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.002509540 Vs 16:52:02 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.002657102 Vs 16:52:12 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.002509007 Vs 16:52:12 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.002583469 +- 0.000000856 Vs 16:52:13 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002583469 +- 0.000000856 Vs BL = -0.02583469 +- 0.00000856 Tm 16:52:13 Integrated Voltage Measurement... 16:52:28 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0100000 m VT = -0.001090763 Vs 16:52:38 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0100000 m VT = 0.000935252 Vs 16:52:48 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0100000 m VT = -0.001087143 Vs 16:52:58 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0100000 m VT = 0.000945520 Vs 16:53:08 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0100000 m VT = -0.001078897 Vs 16:53:19 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0100000 m VT = 0.000939734 Vs 16:53:29 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0100000 m VT = -0.001091513 Vs 16:53:39 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0100000 m VT = 0.000938307 Vs 16:53:39 Integrated Voltage Average and RMS of Measurements X0 = -0.0050000 m, Delta X = 0.0100000 m VT = -0.001013391 +- 0.000002632 Vs 16:53:39 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0050000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001013391 +- 0.000002632 Vs BL = -0.01013391 +- 0.00002632 Tm 16:53:39 Integrated Voltage Measurement... 16:53:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000490403 Vs 16:54:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000623413 Vs 16:54:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000487737 Vs 16:54:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000628148 Vs 16:54:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000490017 Vs 16:54:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000624808 Vs 16:54:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000491248 Vs 16:55:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000630788 Vs 16:55:06 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000558320 +- 0.000001600 Vs 16:55:06 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000558320 +- 0.000001600 Vs BL = 0.00558320 +- 0.00001600 Tm 16:55:06 Integrated Voltage Measurement... 16:55:21 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0100000 m VT = 0.002062084 Vs 16:55:31 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0100000 m VT = -0.002199800 Vs 16:55:41 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0100000 m VT = 0.002052380 Vs 16:55:52 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0100000 m VT = -0.002203901 Vs 16:56:02 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0100000 m VT = 0.002052998 Vs 16:56:12 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0100000 m VT = -0.002204470 Vs 16:56:22 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0100000 m VT = 0.002049596 Vs 16:56:32 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0100000 m VT = -0.002204004 Vs 16:56:32 Integrated Voltage Average and RMS of Measurements X0 = 0.0050000 m, Delta X = 0.0100000 m VT = 0.002128654 +- 0.000001495 Vs 16:56:32 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0050000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.002128654 +- 0.000001495 Vs BL = 0.02128654 +- 0.00001495 Tm 16:56:32 Integrated Voltage Measurement... 16:56:48 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.003620154 Vs 16:56:58 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.003771993 Vs 16:57:08 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.003623219 Vs 16:57:18 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.003767577 Vs 16:57:29 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.003634897 Vs 16:57:39 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.003768295 Vs 16:57:49 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.003628591 Vs 16:57:59 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.003767529 Vs 16:57:59 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.003697782 +- 0.000002410 Vs 16:57:59 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.003697782 +- 0.000002410 Vs BL = 0.03697782 +- 0.00002410 Tm 16:57:59 Integrated Voltage Measurement... 16:58:14 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0100000 m VT = 0.005198575 Vs 16:58:25 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0100000 m VT = -0.005337878 Vs 16:58:35 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0100000 m VT = 0.005199138 Vs 16:58:45 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0100000 m VT = -0.005340233 Vs 16:58:55 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0100000 m VT = 0.005191860 Vs 16:59:05 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0100000 m VT = -0.005346882 Vs 16:59:16 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0100000 m VT = 0.005191641 Vs 16:59:26 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0100000 m VT = -0.005347669 Vs 16:59:26 Integrated Voltage Average and RMS of Measurements X0 = 0.0150000 m, Delta X = 0.0100000 m VT = 0.005269234 +- 0.000000595 Vs 16:59:26 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0150000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.005269234 +- 0.000000595 Vs BL = 0.05269234 +- 0.00000595 Tm 16:59:26 Integrated Voltage Measurement... 16:59:41 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.006768916 Vs 16:59:51 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.006909431 Vs 17:00:02 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.006769002 Vs 17:00:12 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.006910360 Vs 17:00:22 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.006772278 Vs 17:00:32 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.006908389 Vs 17:00:42 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.006773447 Vs 17:00:53 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.006904801 Vs 17:00:53 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.006839578 +- 0.000000488 Vs 17:00:53 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.006839578 +- 0.000000488 Vs BL = 0.06839578 +- 0.00000488 Tm 17:01:01 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00558 0.00001 1 3.14092 0.00035 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ---------- --------+-------- -------- -------- -0.020000 -0.05725 0.00002 -0.05724 -0.00001 -0.015000 -0.04152 0.00002 -0.04154 0.00001 -0.010000 -0.02583 0.00001 -0.02583 -0.00000 -0.005000 -0.01013 0.00003 -0.01013 -0.00001 0.000000 0.00558 0.00002 0.00558 0.00001 0.005000 0.02129 0.00001 0.02128 0.00000 0.010000 0.03698 0.00002 0.03699 -0.00001 0.015000 0.05269 0.00001 0.05269 0.00000 0.020000 0.06840 0.00000 0.06840 0.00000 17:01:01 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 9 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0200 -0.05725 0.00002 -0.0150 -0.04152 0.00002 -0.0100 -0.02583 0.00001 -0.0050 -0.01013 0.00003 0.0000 0.00558 0.00002 0.0050 0.02129 0.00001 0.0100 0.03698 0.00002 0.0150 0.05269 0.00001 0.0200 0.06840 0.00000 SL = 3.1409156 +- 0.0003455 Tm^2/m^n 17:01:01 Quadrupole Strength Calculation Check Slope = 3.140916 Tm/m, Inter = 0.005577 Tm, Sig_slope = 0.000212 Tm/m, Est_sig = 0.000008 Tm GL = 3.140916 +- 0.000212 T 17:01:01 Magnet Strength Measurement Harmonic Number = 2 SL = 3.1409156 +- 0.0003455 Tm^2/m^n 17:01:02 Magnet Current, Imag = 121.8617 A Vtrans = 1.218617 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:01:04 Magnet Current, Imag = 121.8586 A Vtrans = 1.218586 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:01:05 Magnet Current, Imag = 121.8621 A Vtrans = 1.218621 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:01:06 Magnet Current, Imag = 121.8567 A Vtrans = 1.218567 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:01:06 Magnet Current Measurement: Imag = 121.8598 +- 0.0022 A 17:01:07 Magnet current ramping to 0.0000 A...