SLAC Magnetic Measurements
Date: 07-02-1996
Time: 14:37:09

Magnet Name: 2Q4W-32
Project: PEP II Injection Line
Test Stand: 1
Measurement Coil: DC100
Operator: J. BRATMAN
Run Number: 1
Comment: STANDARD MEASUREMENT (180 AMPS)

Standardization Currents (A):
   180.0     2.0   180.0     2.0   180.0     2.0   180.0
     2.0   180.0     2.0   180.0     2.0

Test Currents (A):
    10.0    30.0    50.0    60.0    70.0    80.0    90.0
   100.0   110.0   120.0   130.0   140.0   150.0   160.0
   180.0   150.0   100.0    50.0


                      HARMONICS MEASUREMENTS

Date: 07-02-1996
Time: 15:13:58
Magnet Name: 2Q4W-32
Project: PEP II Injection Line
Run Number: 1


                          FIELD HARMONICS

Magnet Current, Imag =  49.99384  +-  1.348699E-05  A
Coil Radius, Rcoil =  .0189973  m
Coil # Turns, Nturns =  30 
Average, # Rotations/Measurement =  8 , # Measurements =  4 

 N   BLn    sigBLn  THspole  sigTH  BLn/BL2 sBLn/BL2
     (Gm)    (Gm)    (deg)   (deg)    (%)     (%)   
--- -------+------- -------+------- -------+------- 
  1   1.528   0.002  -31.75    0.08   1.066   0.002
  2 143.314   0.022  -45.25    0.00 100.000   0.000
  3   0.530   0.001   -1.55    0.28   0.370   0.001
  4   0.195   0.007   26.25    0.47   0.136   0.005
  5   0.056   0.012  -20.96    3.63   0.039   0.008
  6   0.198   0.027   10.44    0.20   0.138   0.019
  7   0.176   0.008   13.61    1.06   0.122   0.006
  8   0.149   0.016   10.95    2.15   0.104   0.011
  9   0.058   0.006   13.05    1.25   0.040   0.004
 10   0.294   0.004    8.71    0.08   0.205   0.003
 11   0.007   0.002    0.53    4.02   0.005   0.002
 12   0.007   0.004   10.17    2.44   0.005   0.003
 13   0.009   0.002   12.57    1.05   0.006   0.001
 14   0.056   0.003    6.29    0.16   0.039   0.002
 15   0.002   0.001    1.33    9.76   0.002   0.001
 16   0.005   0.003    2.72    7.92   0.004   0.002


The magnetic center is at
X =  -106.6 +-     0.3 microns
Y =   172.2 +-     0.3 microns

The magnetic center is measured relative to the coil axis
effectively at the longitudinal center of the magnet.
Pitch and yaw are not seen by the coil.

View from the non lead end of the magnet:

           y          
           ^          
           |          
        S     N       

                --> x 

        N     S       

Date: 07-02-1996
Time: 15:40:10
Magnet Name: 2Q4W-32
Project: PEP II Injection Line
Run Number: 1


                          FIELD HARMONICS

Magnet Current, Imag =  109.9693  +-  3.318348E-04  A
Coil Radius, Rcoil =  .0189973  m
Coil # Turns, Nturns =  30 
Average, # Rotations/Measurement =  8 , # Measurements =  4 

 N   BLn    sigBLn  THspole  sigTH  BLn/BL2 sBLn/BL2
     (Gm)    (Gm)    (deg)   (deg)    (%)     (%)   
--- -------+------- -------+------- -------+------- 
  1   3.521   0.004  -29.15    0.07   1.118   0.001
  2 314.977   0.024  -45.19    0.00 100.000   0.000
  3   0.935   0.011   -1.67    0.17   0.297   0.004
  4   0.465   0.021   27.15    0.59   0.148   0.007
  5   0.099   0.006  -14.95    1.01   0.031   0.002
  6   0.471   0.007   15.24    0.48   0.150   0.002
  7   0.327   0.026   11.69    0.75   0.104   0.008
  8   0.124   0.025   20.96    0.74   0.039   0.008
  9   0.041   0.007    8.74   16.66   0.013   0.002
 10   0.631   0.007    8.75    0.07   0.200   0.002
 11   0.008   0.005  -11.40    3.29   0.002   0.002
 12   0.012   0.002   11.74    0.61   0.004   0.001
 13   0.017   0.004   11.96    1.27   0.005   0.001
 14   0.133   0.002    6.38    0.10   0.042   0.001
 15   0.007   0.003   -8.39    2.63   0.002   0.001
 16   0.020   0.002   -0.95    0.88   0.006   0.001


The magnetic center is at
X =  -103.4 +-     0.3 microns
Y =   185.4 +-     0.2 microns

The magnetic center is measured relative to the coil axis
effectively at the longitudinal center of the magnet.
Pitch and yaw are not seen by the coil.

View from the non lead end of the magnet:

           y          
           ^          
           |          
        S     N       

                --> x 

        N     S       

Date: 07-02-1996
Time: 16:06:30
Magnet Name: 2Q4W-32
Project: PEP II Injection Line
Run Number: 1


                          FIELD HARMONICS

Magnet Current, Imag =  179.951  +-  1.32145E-04  A
Coil Radius, Rcoil =  .0189973  m
Coil # Turns, Nturns =  30 
Average, # Rotations/Measurement =  8 , # Measurements =  4 

 N   BLn    sigBLn  THspole  sigTH  BLn/BL2 sBLn/BL2
     (Gm)    (Gm)    (deg)   (deg)    (%)     (%)   
--- -------+------- -------+------- -------+------- 
  1   5.841   0.005  -29.01    0.07   1.140   0.001
  2 512.254   0.035  -45.18    0.00 100.000   0.000
  3   1.560   0.011   -3.26    0.15   0.305   0.002
  4   0.715   0.013   26.93    0.34   0.140   0.003
  5   0.345   0.011  -18.67    0.28   0.067   0.002
  6   0.794   0.038   12.83    0.42   0.155   0.007
  7   0.290   0.037    9.15    0.82   0.057   0.007
  8   0.048   0.004   15.25    1.06   0.009   0.001
  9   0.191   0.008   13.93    0.49   0.037   0.002
 10   0.985   0.011    8.79    0.03   0.192   0.002
 11   0.013   0.004    6.29    7.30   0.002   0.001
 12   0.016   0.002   10.29    1.30   0.003   0.000
 13   0.025   0.004   12.39    0.53   0.005   0.001
 14   0.201   0.001    6.44    0.11   0.039   0.000
 15   0.012   0.007   -1.37    6.98   0.002   0.001
 16   0.018   0.007    0.58    6.79   0.003   0.001


The magnetic center is at
X =  -105.0 +-     0.3 microns
Y =   189.4 +-     0.2 microns

The magnetic center is measured relative to the coil axis
effectively at the longitudinal center of the magnet.
Pitch and yaw are not seen by the coil.

View from the non lead end of the magnet:

           y          
           ^          
           |          
        S     N       

                --> x 

        N     S       


           SUMMARY OF THE CALCULATIONS AND CONVENTIONS USED


Calculation of GL using a double coil (assumed flat):
V2 = (Nturns * velocity * B2 * L)_1 + (Nturns * velocity * B2 * L)_2
   = (Nturns1 * Rcoil1 * ang_freq * GL * Rcoil1)
          + (Nturns2 * Rcoil2 * ang_freq * GL * Rcoil2)
   = (Nturns1 * Rcoil1^2 + Nturns2 * Rcoil2^2) * ang_freq * GL
If Nturns1 = Nturns2 == Nturns12, then
V2 = Nturns12 * (Rcoil1^2 + Rcoil2^2) * ang_freq * GL
Let Reff^2 = Rcoil1^2 + Rcoil2^2, then
V2 = Nturns12 * Reff^2 * ang_freq * GL
Or,
GL = V2 / (Nturns12 * Reff^2 * ang_freq)


Calculation of the harmonics:
The integrated radial field for the n'th harmonic at the
coil radius is given by
BLn(th) = BLn * cos(n*(th - THspole))
The coil voltage is V = Nturns * v_theta * B_r * L
Vn(th) = Nturns * velocity * BLn(th)
       = Nturns * Rcoil * ang_freq * BLn * cos(n*(th - THspole))
The FFT gives Vn and PhiVn in the formula
Vn(i) = Vn * cos(n*2pi*i/N + PhiVn)
Then,
Vn = Nturns * Rcoil * ang_freq * BLn
PhiVn = - n * THspole
Or,
BLn = Vn / (Nturns * Rcoil * ang_freq)
THspole = - PhiVn / n


Calculation of the magnetic center:
Xcenter = - (1/GL) * BL1 * sin(THspole1)